Nominal data
Type
R3G310-AX54-21
Motor
M3G112-EA
Phase
1~
Nominal voltage
VAC
230
Nominal voltage range
VAC
200 .. 277
Frequency
Hz
50/60
Method of obtaining data
ml
Speed
min-1
2850
Power consumption
W
1270
Current draw
A
5.6
Min. ambient temperature
°C
-25
Max. ambient temperature
°C
60
ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment
Subject to change
Data according to ErP Directive
01 Overall efficiency ηes
%
Actual
Req. 2015
59.4
52.6
09 Power consumption Ped
kW
1.27
02 Measurement category
A
09 Air flow qv
m³/h
2790
03 Efficiency category
Static
09 Pressure increase pfs
Pa
903
10 Speed n
min-1
2840
04 Efficiency grade N
68.8
05 Variable speed drive
Yes
62
Data obtained at optimum efficiency level.
The ErP data is determined using a motor-impeller combination in a standardized measurement setup.
11 Specific ratio*
*
Specific ratio = 1 + pfs / 100 000 Pa
1.01
LU-126020
Item no. 50235-5-9980 · ENU · Change 84593 · Approved 2015-01-05 · Page 1 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
EC centrifugal fan - RadiPac
R3G310-AX54-21
backward-curved, single-intake
Technical description
Weight
11 kg
Fan size
310 mm
Rotor surface
Painted black
Electronics housing material
Die-cast aluminum
Impeller material
Sheet aluminum
Number of blades
7
Direction of rotation
Clockwise, viewed toward rotor
Degree of protection
IP54
Insulation class
"B"
Moisture (F) / Environmental (H)
protection class
F4-1
Max. permitted ambient temp.
for motor (transport/storage)
+80 °C
Min. permitted ambient temp. for
motor (transport/storage)
-40 °C
Installation position
Shaft horizontal or rotor on bottom; rotor on top on request
Condensation drainage holes
On rotor side
Mode
S1
Motor storage
Ball bearing
Technical features
- RS-485 MODBUS-RTU
- Control input 0-10 VDC / PWM
- Tach output
- Thermal overload protection for electronics/motor
- Alarm relay
- PFC, active
- Integrated PID controller
- Input for sensor 0-10 V or 4-20 mA
- Output for slave 0-10 V
- Motor current limitation
- Soft start
- Line undervoltage / phase failure detection
- Output 10 VDC, max. 10 mA
- Output 20 VDC, max. 50 mA
Touch current according to IEC
60990 (measuring circuit Fig. 4,
TN system)
<= 3.5 mA
Electrical hookup
Via terminal box
Motor protection
Thermal overload protector (TOP) internally connected
With cable
Variable
Protection class
I (with customer connection of protective earth)
Conformity with standards
CE
Approval
EAC; UL 1004-7 + 60730
Item no. 50235-5-9980 · ENU · Change 84593 · Approved 2015-01-05 · Page 2 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
R3G310-AX54-21
EC centrifugal fan - RadiPac
backward-curved, single-intake
Product drawing
1
Cable diameter min. 4 mm, max. 10 mm; tightening torque 4 ± 0.6 Nm
2
Accessory part: inlet ring 31575-2-4013 not included in scope of delivery
3
Clearance for screw 12-16 mm
4
Tightening torque 3.5 ± 0.5 Nm
Item no. 50235-5-9980 · ENU · Change 84593 · Approved 2015-01-05 · Page 3 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
R3G310-AX54-21
EC centrifugal fan - RadiPac
backward-curved, single-intake
Connection diagram
No.
Conn.
Designation
Function/assignment
KL1
1
L1
Supply connection, power supply 1-phase 200-277 VAC; 50/60 Hz
KL1
2
N
Supply connection, power supply 1-phase 200-277 VAC; 50/60 Hz
PE
PE
Ground connection, PE connection
KL2
1
NO
Status relay, floating status contact; Option 1: Make for failure; Option 2: Make for run monitoring error
message
KL2
2
COM
Status relay, floating status contact; changeover contact; common connection; contact rating 250 VAC/
max. 2 A (AC1)/min. 10 mA
KL2
3
NC
Status relay, floating status contact; Option 1: Break for failure; Option 2: Break for run monitoring error
message
KL3
1
RSA
Bus connection RS485; RSA; MODBUS RTU
KL3
2
RSB
Bus connection RS485; RSB; MODBUS RTU
KL3
3
GND
Reference ground for control interface
KL3
4
Ain1 U
Analog input 1 (set value); 0-10 V; Ri = 100 kohms; adjustable curve; only for use as alternative to input
Ain1 I
KL3
5
+10 V
Fixed voltage output 10 VDC; +10 V ±3%; max. 10 mA; short-circuit-proof power supply for ext.
devices (e.g. potentiometer)
KL3
6
Ain1 I
Analog input 1 (set value); 4-20 mA; Ri = 100 ohms; adjustable curve; only for use as alternative to input
Ain1 U
KL3
7
Din1
Digital input 1: Enable electronics; Enable: Pin open or applied voltage 5...50 VDC; Disable: Bridge to
GND or applied voltage < 0.8 VDC; Reset function: Triggering of software reset after level change to < 0.8 V
KL3
8
Din2
Digital input 2: Parameter set 1/2 switching; Depending on EEPROM setting, the valid/used parameter set
can be selected via BUS or digital input DIN2. Parameter set 1: Pin open or applied voltage 5...50 VDC;
Parameter set 2: Bridge to GND or applied voltage < 0.8 VDC
KL3
9
Din3
Digital input 3: Direction of action of integrated controller; According to EEPROM setting, the direction of
action of the integrated controller can be selected as normal/inverse via bus or digital input; Normal: Pin
open or applied voltage 5...50 VDC; Inverse: Bridge to GND or applied voltage < 0.8 VDC
KL3
10
GND
Reference ground for control interface
KL3
11
Ain2 U
Analog input 2; Measured value 0-10 V; Ri = 100 kohms; adjustable curve; only for use as alternative to
input Ain2 I
KL3
12
+20 V
Fixed voltage output 20 VDC; +20 V +25/-10%; max. 50 mA; short-circuit-proof power supply for ext.
devices (e.g. sensors)
KL3
13
Ain2 I
Analog input 2; measured value: 4-20 mA; Ri = 100 ohms; adjustable curve; only for use as alternative to
input Ain2 U
Item no. 50235-5-9980 · ENU · Change 84593 · Approved 2015-01-05 · Page 4 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
R3G310-AX54-21
EC centrifugal fan - RadiPac
backward-curved, single-intake
No.
Conn.
Designation
Function/assignment
KL3
14
Aout
Analog output 0-10 V; max. 5 mA; output of current motor modulation level/of current motor speed
Adjustable curve.
Item no. 50235-5-9980 · ENU · Change 84593 · Approved 2015-01-05 · Page 5 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
EC centrifugal fan - RadiPac
R3G310-AX54-21
backward-curved, single-intake
Curves: Air performance 50 Hz
Druck p f s[Pa]für Rho=1,2kg/m^3
500
qv[cfm]
1.500
1.000
2.000
2.500
3.000
5,2
1.250
5
1.200
4,8
1.150
4,6
1.100
1.050
4,2
1.000
4
950
3,8
900
3,6
850
3,2
3
750
3
700
pf s[Pa]
Air performance measured according to ISO
5801 installation category A. For detailed
information on the measurement setup,
contact ebm-papst. Intake sound level:
Sound power level according to ISO 13347 /
sound pressure level measured at 1 m
distance from fan axis. The values given are
valid under the specified measuring
conditions and may vary due to conditions of
installation. For deviations from the standard
configuration, the parameters have to be
checked on the installed unit.
3,4
8
800
2,8
650
2,6
600
2,4
7
550
2,2
12
500
2
450
1,8
2
400
1,6
11
350
1,4
6
16
300
1,2
250
1
15
200
150
10
0,8
0,6
14
13
0
500
1.000
1.500
2.000
9
2.500
3.000
qv[m^3/h]
3.500
]
[Pa
pf s
]
[Pa
pf s
a]
s[P
pf
50
a]
pf s[P
100
0
Measurement: LU-126020
Measurement: LU-131413
Measurement: LU-131415
Measurement: LU-131416
4,4
4
p fs_E[IN H2O]
1.300
0
1
5
4.000
4.500
5.000
0,4
0,2
0
Measured values
U
f
n
Ped
I
LpAin
LwAin
LwAout
qv
pfs
V
Hz
min-1
W
A
dB(A)
dB(A)
dB(A)
m3/h
Pa
1
230
50
2930
946
4.14
81
88
94
4980
0
2
230
50
2895
1147
5.01
76
83
90
4340
425
3
230
50
2850
1270
5.60
72
79
87
3410
760
4
230
50
2850
1237
5.41
75
83
89
2300
1050
5
230
50
2430
529
2.34
77
84
89
4165
0
6
230
50
2430
663
2.91
71
78
85
3585
309
7
230
50
2430
743
3.26
70
77
84
2925
556
8
230
50
2430
751
3.29
71
78
85
1980
781
9
230
50
1955
299
1.36
71
78
83
3345
0
10
230
50
1955
360
1.61
66
73
79
2860
193
11
230
50
1955
398
1.77
65
72
78
2335
356
12
230
50
1955
400
1.78
66
73
79
1585
499
13
230
50
1465
139
0.72
64
71
76
2505
0
14
230
50
1465
159
0.79
59
67
73
2130
106
15
230
50
1465
177
0.86
58
65
72
1735
196
16
230
50
1465
184
0.89
59
66
73
1185
280
U = Power supply · f = Frequency · n = Speed · Ped = Power consumption · I = Current draw · LpAin = Sound pressure level intake side · LwAin = Sound power level intake side
LwAout = Sound power level outlet side · qv = Air flow · pfs = Pressure increase
Item no. 50235-5-9980 · ENU · Change 84593 · Approved 2015-01-05 · Page 6 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
Similar pages