Total Power HPU100-13 Universal ac input harmonic correction ac-dc 19 compatible eurocard 100 watts multiple output switching mode power supplies hpu100 sery Datasheet

TOTAL POWER INT'L
UNIVERSAL AC INPUT HARMONIC CORRECTION AC-DC
19" COMPATIBLE EUROCARD 100 WATTS MULTIPLE OUTPUT
SWITCHING MODE POWER SUPPLIES HPU100 SERIES
FEATURES:
ACCOMMODATE UNIVERSAL AC SOURCES
MEET IEC1000-3-2 HARMONIC CORRECTION
MEET UNIVERSAL SAFETY STANDARDS
19” COMPATIBLE EUROCARD FORMAT
EMI MEET EN 55022 & FCC CLASS B
CE MARKING COMPLIANCE
3U X 10HP X 160MM VMEbus STANDARD
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: Typ. 90-264Vac with PFC.
Input Connector: DIN 41612 at rear.
Input Frequency: 47-63Hz.
Inrush Current: Typ. <30.6A @ 230Vac.
Input Current: 1.0A @ 115Vac, 0.5A @ 230Vac.
Dielectric Withstand: Meet IEC950.
EMI: Meet EN 55022 & FCC B.
Power Factor Correction: Meet Harmonic Correction
IEC1000-3-2 .PF typ. 0.97-0.98.
Power Indicator: Green LED.
Power OK Signal: Installed.
Logic Inhibit: Installed.
Hold-up Time: 20mS @ 115Vac & 230Vac.
Earth Leakage: Less than 0.40mA @ 230Vac.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Connector: DIN 41612 at rear.
Line Regulation: Typ. 0.5%.
Load Regulation: Main VO1 typ. ±1-2.0%.
Aux.VO2 typ. ±2.0% (Mag. Amp.)
Aux.VO3 typ. ±3.0% (PR).
Noise & Ripple: Typ. 1% peak to peak.
OVP: Built-in at main VO1.
Adjustability: Available at VO1 & VO2.
Overload Protection (OLP): Fully protected against
output overload and short circuit.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: Typ. 73-76%.
Switching Frequency: Fixed frequency 83K Hz.
Circuit Topology: Fixed frequency forward circuit.
Transient Response: Output voltage returns in less than
3mS following a 25% load change.
Safety Standard: IEC950/UL1950 Class I.
Power Density: 2.0 Watt / Cubic Inch.
Operating Temperature: 0 to +50°C full load. Derates
from +50 to +70°C by derating 2%/°C.
Storage Temperature: -25 to +85°C.
Temperature Coefficient: Typ. 0.04% /°C.
Cooling: Forced air flow is recommended for Ta > +50°C
full load operation.
Construction format: 10HP(TE) X3UX160mm VMEbus
standard Eurocard format.
Note: All measurements are at nominal input, full load, and +25℃ unless otherwise specified.
OUTPUT VOLTAGE/CURRENT RATINGS CHART
SINGLE OUTPUT
DUAL OUTPUT
MAIN VO1 @#
Typ.
Volt.
25.0A
3.3V
MODEL NO.
HPU100-S033250
HPU100-S050200
MAIN VO1 @◇
Typ.
Volt.
MODEL NO.
HPU100-D050I
8.0A
5.0V
5.0A
12.0V
4.2A
12.0V
4.2A
12.0V
8.0A
5.0V
4.0A
15.0V
3.4A
15.0V
3.4A
15.0V
11.0A
11.0A
3.3V
3.3V
5.0A
4.0A
12.0V
15.0V
20.0A
5.0V
(HPU100-20)
8.0A
7.5A
12.0V
15.0V
(HPU100-21)
4.2A
24.0V
3.6A
2.8A
2.1A
28.0V
36.0V
48.0V
HPU100-D033I
HPU100-D033K
MAIN VO1 @◇
Typ.
Volt.
7.0A
5.0V
AUX. VO2 @▲◇
Typ.
Volt.
5.0A
12.0V
AUX. VO3 ●◇
Typ.
Volt.
1.0A
5.0V
(HPU100-10)
HPU100-S120080
HPU100-S150075
HPU100-S240042
(HPU100-13)
HPU100-S280036
HPU100-S360028
HPU100-S480021
AUX. VO2 @▲◇
Typ.
Volt.
HPU100-D120I
HPU100-D050K
HPU100-D150K
(HPU100-23)
TRIPLE OUTPUT
MODEL NO.
HPU100-T050IE
HPU100-T050KK
7.0A
5.0V
4.0A
15.0V
0.4A
15.0V
7.0A
5.0V
5.0A
12.0V
0.5A
12.0V
11.0A
10.0A
10.0A
3.3V
3.3V
3.3V
9.0A
4.0A
5.0A
5.0V
15.0V
12.0V
1.0A
0.6A
0.8A
12.0V
15.0V
12.0V
(HPU100-31)
HPU100-T050II
(HPU100-32)
HPU100-T033EI
HPU100-T033KK
HPU100-T033II
Symbol: " " OVP built-in. "@" Adjustable. "#" Remote sensing. "▲" Magnetic Amplifier.
"◇" Floating (or isolated) output. "●" Installed with Post Regulator.
MECHANICAL DIMENSIONS: MM [INCHES]
WEIGHT: 920.0g (32.5 Oz.)
INPUT & OUTPUT CONNECTORS PIN ASSIGNMENT
AC INPUT
ASSIGNMENT
CNTR & Pin#
SINGLE OUTPUT
AC- AC- AC+VO1 +S -VO1 -S
L
N
G
28
30
32
4,6
Mating connector: DIN 41612-H15 Female
8
12,14 10
DUAL OUTPUT
NC
16,18,
24,26
+VO1 -VO1 +VO2 -VO2
4
6
8
10
Status/
Control
Log.
+VO1 -VO1 +VO2 -VO2 +VO3 -VO3 NC
P.Ok
Inh.
TRIPLE OUTPUT
NC
12,14,16
18,24,26
4,6
8,10
12
14
16
18
24,26
20
22
Similar pages