Murata HB04U12S05QC 4.0w unregulated high isolation dc/dc converter Datasheet

HB04UC
4.0W Unregulated High Isolation DC/DC Converter
DESCRIPTION
The HB04UC Series is a low-cost, high-isolation voltage, unregulated, single and dual output DC/DC converter. The dielectric
withstand characteristics of each converter is tested in production
to ensure barrier integrity.
The HB04UC Series uses advanced circuit design and packaging technology to realize superior reliability and performance.
A 100kHz driven push-pull oscillator is used to ensure stable
frequency and non-saturating operation of the input stage. This
means there are no high peak voltages or currents like other
design topologies, which can reduce unit reliability. Reduced
parts count adds to the reliability of the HB04UC Series.
FEATURES
L
L
L
L
L
L
L
ROHS COMPLIANT
HIGH ISOLATION - 3000V RATING
8000V ISOLATION TEST VOLTAGE
BARRIER 100% PRODUCTION TESTED
LOW BARRIER CAPACITANCE - 10PF
LOW LEAKAGE CURRENT - 2μA MAX
INTERNAL FILTERING
The high efficiency of the HB04UC Series means less internal
power dissipation. With less heat to dissipate, the HB04UC
Series can operate over a wider ambient temperature range
with no degradation of reliable operation.
The HB04UC Series offers the user low cost without sacrificing
reliability. The use of surface mounted devices and manufacturing technologies make it possible to offer premium performance
at low cost.
APPLICATIONS
L
L
L
L
L
BIOMEDICAL DATA ACQUISITION
INDUSTRIAL PROCESS CONTROL
ANALYTICAL MEASUREMENTS
GROUND LOOP ELIMINATION
INTRINSIC SAFETY SYSTEMS
MECHANICAL
0.400±0.010"
(10.16)
1.00±0.015"
(25.40±0.38)
0.015±0.005"
(0.38)
HBO4UC
0.040±.003"
(1.02±0.08)
Notes: All dimensions are in inches (millimeters).
2.00±0.015"
(50.80±0.38)
+VIN
0.170"
MIN
(4.32)
GRID: 0.100 inches (2.54 millimeters)
+VOUT
PIN PLACEMENT TOLERANCE: ± 0.015"
COMMON PIN: Not connected internally on single output models
MARKED WITH: date code, job code.
COMM
-VIN
-VOUT
MATERIAL: Units are encapsulated in a low thermal resistance molding compound which has excellent
chemical resistance, wide operating temperature range, and good electrical properties under high humidity
environments. The encapsulant and outer shell of the unit have UL94V-0 ratings. Lead material is brass;
lead finish is a 100-300 micro-inch layer of matte tin over a 5-40 micro-inch barrier layer of nickel.
More product information and application notes are available
on our website at www.murata-ps.com
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
ISO9001
CERTIFIED
Technical enquiries - email: [email protected], tel: +1 508 339 3000
HB04UC.A01 Page 1 of 3
HB04UC
4.0W Unregulated High Isolation DC/DC Converter
ELECTRICAL SPECIFICATIONS
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise noted.
MODEL
NOMINAL
INPUT
VOLTAGE
(VDC)
RATED
OUTPUT
VOLTAGE
(VDC)
RATED
OUTPUT
CURRENT
(mA)
INPUT CURRENT
NO LOAD
(mA)
RATED LOAD
(mA)
EFFICIENCY
(%)
HB04U05S05QC
HB04U05S12QC
HB04U05S15QC
5
5
5
5
12
15
800
333
267
60
60
60
1000
1000
1000
80
80
80
HB04U12S05QC
HB04U12S12QC
HB04U12S15QC
12
12
12
5
12
15
800
333
267
25
25
25
380
380
380
87
87
87
HB04U15S05QC
HB04U15S12QC
HB04U15S15QC
15
15
15
5
12
15
800
333
267
20
20
20
310
310
310
87
87
87
HB04U05D05QC
HB04U05D12QC
HB04U05D15QC
5
5
5
±5
±12
±15
±400
±167
±134
60
60
60
944
944
944
85
85
85
HB04U12D05QC
HB04U12D12QC
HB04U12D15QC
12
12
12
±5
±12
±15
±400
±167
±134
25
25
25
375
375
375
88
88
88
HB04U15D05QC
HB04U15D12QC
HB04U15D15QC
15
15
15
±5
±12
±15
±400
±167
±134
20
20
20
300
300
300
88
88
88
MIN
TYP
MAX
UNITS
4.5
10.8
13.5
5
12
15
351
5.5
13.2
16.5
VDC
Note: Other input to output voltage options may be available. Please consult factory.
Models with strikethrough have been discontinued.
COMMON SPECIFICATIONS
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise noted.
PARAMETER
CONDITIONS
INPUT
Voltage Range
Reflected Ripple Current
ISOLATION
Rated Voltage
Test Voltage
Resistance
Capacitance
Leakage Current
OUTPUT
Rated Power
Voltage Setpoint Accuracy
Temperature Coefficient
Ripple & Noise
BW = 10Hz to 2MHz
Line Regulation
Load Regulation
GENERAL
Switching Frequency
Package Weight
MTTF per MIL-HDBK-217, Rev. E
Ground Benign
60 Hz, 10 Seconds
mAp-p
3000
8000
10
10
1.2
VISO= 240VAC, 60Hz
4
±3
±0.02
100
20
±1.5
BW = DC to 10MHz
High Line to Low Line
See performance curves
2
±5
100
22
Circuit Stress Method
TA = +25°C
TEMPERATURE
Specification
Operation
Storage
W
%
%/°C
mVp-p
mVrms
%/% Vin
kHz
g
200,000
-25
-40
-40
VDC
Vpk
GΩ
pF
μArms
Hr
+70
+85
+110
°C
°C
°C
1. Reflected ripple current is measured at 50% load with a 33uF capacitor across the input of the UUT.
www.murata-ps.com
Technical enquiries - email: [email protected], tel: +1 508 339 3000
HB04UC.A01 Page 2 of 3
HB04UC
4.0W Unregulated High Isolation DC/DC Converter
THROUGH-HOLE SOLDERING INFORMATION
These devices are intended for wave soldering or manual soldering.
They are not intended to be subject to surface mount processes under any circumstances.
The normal wave soldering process can be used with these devices where the device is subjected to a maximum wave temperature of 260°C for a period of
no more than 10 seconds. Within this time and temperature range, the integrity of the device’s plastic body will not be compromised and internal temperatures
within the converter will not exceed 175°C. Care should be taken to control manual soldering limits identical to that of wave soldering.
ORDERING INFORMATION
ABSOLUTE MAXIMUM RATINGS
HB04U xxyzz Q
Internal Power Dissipation.....................................................................1W
Short Circuit Duration................................................................Momentary
Lead Temperature (soldering, 10 seconds max)..............................+300°C
C
Device Family
HB04U Indicates DC/DC Converter
Model Number
Where:
xx = Input Voltage
y = Number or Outputs (Single "S", Dual "D")
zz = Output Voltage
Package Option
RoHS Compliant
TYPICAL PERFORMANCE CURVES
VOUT VS LOAD
(±5Vout Models)
7.5
7.0
7.0
6.5
6.5
VOUT
VOUT
VOUT VS LOAD
(5Vout Models)
7.5
6.0
5.5
6.0
5.5
5.0
5.0
0
25
50
IOUT (%)
75
100
0
25
16
15
15
14
14
13
100
75
100
75
100
13
12
12
11
11
0
25
50
IOUT (%)
75
100
0
25
VOUT VS LOAD
(15Vout Models)
50
IOUT (%)
VOUT VS LOAD
(±15Vout Models)
22.5
22.5
21.0
21.0
19.5
19.5
VOUT
VOUT
75
VOUT VS LOAD
(±12Vout Models)
16
VOUT
VOUT
VOUT VS LOAD
(12Vout Models)
50
IOUT (%)
18.0
18.0
16.5
16.5
15.0
15.0
0
25
50
IOUT (%)
75
100
0
25
50
IOUT (%)
EFFICIENCY VS LOAD
Efficiency (%)
100
80
60
40
20
0
0
www.murata-ps.com
25
50
IOUT (%)
75
100
Technical enquiries - email: [email protected], tel: +1 508 339 3000
HB04UC.A01 Page 3 of 3
HB04UC
4.0W Unregulated High Isolation DC/DC Converter
USA:
Mansfield (Ma), Tel: (508) 339-3000, email: [email protected]
Canada: Toronto, Tel: (866) 740 1232, email: [email protected]
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com email: [email protected] ISO 9001 REGISTERED
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2008 Murata Power Solutions, Inc.
www.murata-ps.com
UK:
Milton Keynes, Tel: +44 (0)1908 615232, email: [email protected]
France:
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: [email protected]
Germany: München, Tel: +49 (0)89-544334-0, email: [email protected]
Japan:
Tokyo, Tel: 3-3779-1031, email: [email protected]
Osaka, Tel: 6-6354-2025, email: [email protected]
Website: www.murata-ps.jp
China:
Shanghai, Tel: +86 215 027 3678, email: [email protected]
Guangzhou, Tel: +86 208 221 8066, email: [email protected]
Technical enquiries - email: [email protected], tel: +1 508 339 3000
HB04UC.A01 Page 4 of 3
Similar pages