MZS-SERIES 䡵 Features (1) Attenuation effect against high voltage pulse noise (2) For equipment designed to conform EMI regulations such as VCCI, CISPR, FCC, VDE, etc. (3) Attenuates conductive emission from power supply (4) Leakage current: 1mA max. (250V, 60Hz) (5) High shielded effect MZS-1215 䡵 Safety standard MZS-1220 ( MZS-1206 MZS-1210 UL1283, CSA Std. C22. 2 No. 8 VDE0565 Teil. 3 VDE0565 will transfer to EN133200 on and after July 23, 2003. ) 䡵 Specifications Model Item 1 Rated voltage (AC, DC) MZS-1206-33 MZS-1210-33 2 Rated current (AC, DC) 3 Test voltage (terminal to case, AC 1 minute) 2500V 4 Isolation resistance (terminal to case, 500VDC) 100MΩ min. 5 Leakage current MZS-1215-33 MZS-1220-33 15A 20A 0.03Ω max. 0.02Ω max. 250V (Note) 6A 10A 125V, 60Hz 0.5mA max. 250V, 60Hz 6 DC resistance 7 Temperature rise 8 Operating temperature range 9 Weight 1mA max. 0.10Ω max. 0.05Ω max. 30°C max. –25 ~ +85°C (typ) 310g (Note) : Value at Ta < = 55°C. Refer to the derating curve shown below at Ta > 55°C. Noise Filter 䡵 Circuit 䡵 Derating R: Breeder resistance 䡵 Outline drawings Case: Metal 䢇 Request customer specification for further details of specifications, outline, characteristics, etc. Read the instruction manual before usage. 䢇 Contact us about delivery before ordering. (Unit: mm) 165 MZS-SERIES CHARACTERISTICS Attenuation (dB) .............. Symmetrical ———— Asymmetrical Attenuation (dB) 䡵 Typical Insertion Loss Frequency (MHz) Frequency (MHz) Attenuation (dB) Attenuation (dB) Noise Filter Frequency (MHz) 166 Frequency (MHz)