Emerson Network Power AEQ60Y48N-6 High efficiency quarter brick Datasheet

Astec Industry Standard
60 Amps
AEQ/ALQ60
Total Power:
Input Voltages:
No. of Outputs:
108W
48V
Single
High Efficiency Quarter Brick
Electrical Specs
Input
Input Range
Input Surge
Efficiency
36 to 75 VDC
100V /100ms
> 90%@1.8V (50% to 100% load)
Output
Line Regulation
Load Regulation
Noise/Ripple
Remote sense
Transient Response
Special Features
• High efficiency
• Industry standard package 1.45" x 2.30"
• Baseplate (AEQ) or Openframe (ALQ)
construction
• High capacitive load limit on start-up
• Remote sense compensation
• Regulation to zero load
• Fixed frequency switching
• Basic insulation
• EU Directive 2002/95/EC Compliant for RoHS
Overvoltage Protection
Current Limit
Switching Frequency
±0.2%Vo
±0.2%Vo
25mV typ
Up to 10% of Vo
4% deviation typical
50% to 75% Load change
0.1A/µs Slew Rate
150µs recovery
125% Vo
115% nominal output
480kHz
Control
Voltage Adjust
90 to 110% Vo
Enable
TTL compatible
(Positive or Negative enable options)
Environmental
Operating temperature range:
-40°C to +85°C ambient (ALQ - Openframe)
-40°C to +105°C baseplate (AEQ - Baseplate)
Storage temperature: -40°C to +125°C
Overtemperature protection: 115°C PCB
temperature (Typical)
MTBF: > 1 million hours
Safety
UL,cUL 60950
TUV
1
EN60950
North America (USA): 1-888-41-ASTEC
Europe (UK): 44 (1384) 842-211
Asia (HK): 852-2437-9662
AMERICAS
EUROPE
ASIA
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
Input
Voltage
Output
Voltage
Output
Current
Efficiency
Model Number
36V to 75V
36V to 75V
1.8V
1.8V
60A
60A
90% Typ
90% Typ
AEQ60Y48(N) - (6)(3)(L)
ALQ60Y48(N) - (6)(3)(L)
AEQ / ALQ60Y48
Ordering Information
OPTIONS
suffix "N" = Negative Logic Enable (without suffix “N” designates Positive Logic Enable)
suffix “6” = 3.7mm pin length (5mm nominal default pin length)
suffix “-3” = single pair of output pins (Pins 4 and 10 unstuffed)
without suffix “-3” = double pair of output pins (Pins 4,5, 9 and 10 are present)
suffix “L” = RoHS compliant (RoHS 6) / “Blank” = RoHS compliant with Lead (Pb) in solder exemption (RoHS 5)
2.30 [58.4]
Ø 0.040(1.02) Dia Pins
6 places
Ø 0.060 (1.52) Dia Pins
4 places
Pin Assignments
1.45 [36.8]
Single Output
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
+Vin
Enable
- Vin
Common
Common
- Sense
Trim
+ Sense
+ Vout
+ Vout
0.58 [14.7]
0.37 [9.4]
0.25 [6.3]
(OPTIONAL)
0.43 [10.8]
2.30 [58.4]
1.02 [26.0]
0.73 [18.4]
0.57 [14.6]
0.42 [10.8]
0.73 [18.4]
4 5
3
(OPTIONAL)
2
1.45 [36.8]
10
1
Notes:
1. Nominal values apply with sense pins connected
to +Vout and Ground Return with other control
pins unconnected.
ALQ - Open
Frame Series
PINASSIGNMENT
1 + VIN
2 Enable (on/off)
3 -VIN
4 -Vout (optional)
5 -Vout
6 -Sense
7 Trim
8 + Sense
9 + Vout
10+ Vout (optional)
All dimensions are in Inches [mm].
Pin placement tolerance 0.005[0.127].
1.02 [26.0]
6
7
8
9
NOTES:
ALL DIMENSIONS ARE IN INCHES (MILLIMETERS)
PIN PLACEMENT TOLERANCE : ± 0.005(0.127)
MECHANICAL TOLERANCE ± .002(0.5)
1.88 [47.7]
0.15 [3.8]
2.00 [50.8]
MOUNTING INSERT (2 PLCS)
M3 X 0.5 THROUGH
MAXIMUM SCREW TORQUE 3.9 IN LBS (0.44 N -m
2.30 [58.4]
2. Consult the Technical Reference Notes for more
detailed information.
0.21 [5.3]
3. Dimensions provided in the mechanical outline
are nominal values.
Ø 0.040(1.02) Dia Pins
6 places
Ø 0.060 (1.52) Dia Pins
4 places
1.03 [26.2]
1.45 [36.8]
1.86 [47.2]
0.22 [5.6]
0.44 [11.2]
5. Specifications subject to change without notice.
0.25 [6.3]
0.65 [16.4]
6. 2 Years warranty.
0.43 [10.8]
2.30 [58.4]
1.02 [26.0]
0.73 [18.4]
0.57 [14.6]
0.42 [10.8]
0.73 [18.4]
4 5
3
2
1.45 [36.8]
10
1
* Astec reserves the right to make changes to the information
contained herein without notice and assumes no liability as a
result of its use or application. (REV03: DECEMBER 20, 2006)
0.15 [3.8]
6
7
8
9
1.02 [26.0]
AEQ - Baseplate Series
Astec Industry Standard
4. At high line, VIN = 75V and no load, VO = 0A, the
module requires 1500µF capacitive load to provide
greater than 45° of phase margin.
1.88 [47.7]
2.00 [50.8]
www.astecpower.com
2