LinkCom LCCH-080U480-00 80w power supply Datasheet

80W Power Supply
Constant Current Mode
80-LCCH Series
www.linkcom.com.tw For more information, please contact with: [email protected]
FEATURES:
● AC Input 90~305 Vac Nominal
● Power Factor: > 0.98 @ 115 Vac / > 0.93 @ 230 Vac; @ full load
● Protection: SCP / OVP / OTP
● High Operating Ambient Temp.: -30 ℃ ~ +70 ℃ (refer to dreating curve)
● Surge Protection: L-N 2 kV, L/N-FG 4 kV
● Safety: UL / PSE
● EMI: Meets FCC/ Meets CE
● Comply with Indoor/Outdoor Waterproof (IP 67)
● Warranty: 5 years (refer to LinkCom warranty policy)
● RoHS Compliant
PRODUCT SPECIFICATION
DC OUTPUT
POWER(W)
DC OUTPUT
VOLTAGE(V)
OUTPUT
CURRENT(A)
OUTPUT
CURRENT
TOLERANCE
EFFICIENCY
O/P NOISE(P-P,V)
LCCH-080U120-00
80.4
8.5-12
6.7
±5%
87%
0.5
LCCH-080U240-00
81.6
18-24
3.4
±5%
88%
0.5
LCCH-080U300-00
81
24-30
2.7
±5%
88%
0.5
LCCH-080U360-00
82.8
30-36
2.3
±5%
90%
0.5
LCCH-080U420-00
79.8
34-42
1.9
±5%
90%
0.5
LCCH-080U480-00
80
40-48
1.7
±5%
90%
0.5
MODEL
ELECTRICAL SPECIFICATION
INPUT VOLTAGE RANGE
90-305 Vac, 127-431 Vdc, Normal: 100-277 Vac
INPUT FREQUENCY
Range: 47-63 Hz, Normal: 50-60 Hz
ACTIVE POWER FACTOR
> 0.98 @ 115 Vac / > 0.93 @ 230 Vac at Full Load and Rated Output Voltage
THD
< 20%
TURN ON DELAY TIME
<1.5 s at Full Load 120-277Vac
AC CURRENT
1.5 A / 115 Vac 0.56 A / 230 Vac
INRUSH CURRENT (Max)
Cold Start 65 A @ 230 Vac
LEAKAGE CURRENT
SHORT CIRCUIT PROTECTION
< 0.45 mA / 264 Vac
short circuit protection will restart automatically after the fault condition is removed
OVER VOLTAGE PROTECTION
OVER TEMP. PROTECTION
shut down and latch off o/p voltage , re-power on to recover
-30℃ ~ +70 ℃ (refer to dreating curve)
OPERATING TEMP.
STORAGE TEMP.
-40℃~+80℃
RELATIVE HUMIDITY
10% to +90%, non-cond.
SAFETY
UL60950-1 / PSE
EMI
Meets EN55015 / Meets FCC part 15
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P: 3 kVac, O/P-Grnd: 1.5 kVac, I/P-Grnd: 1.5 kVac
I/P-O/P, I/P-FG,O/P-FG :10M Ω / 500 Vdc / 25℃ / 70% RH
DIMENSION (L*W*H)
208.4 * 72 * 38.5 mm【8.2 * 2.83 * 1.52 inch】
(1) All parameters specified at 230 Vac input unless otherwise noted
(2) All specifications Typical at 25℃, unless otherwise noted, at normal line and load.
(3) Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk at 20MHz bandwidth.
(4) Specified for free-air convection cooling.
(5) Minimum load is NOT required for proper operation .
(6) 100% Production Tested.
*REFERENCE: www.linkcom.com.tw
*Please contact [email protected], [email protected] for more information
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw
80W Power Supply
Constant Current Mode
80-LCCH Series
www.linkcom.com.tw For more information, please contact with: [email protected]
DIMENSIONS
Tc Max.
LCCH-080U420 as Tc Max. Reference
*REFERENCE: www.linkcom.com.tw
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw
80W Power Supply
Constant Current Mode
80-LCCH Series
www.linkcom.com.tw For more information, please contact with: [email protected]
Output Current vs. Load(LCCH-080P480-E0)
Output Current vs. Load
Output Current (A)
1.740
1.720
1.700
Vin=100
Vin=120
1.680
Vin=200
Vin=230
Vin=277
1.660
65%
70%
75%
80%
85%
90%
95%
100%
105%
Load (%)
Efficiency vs. Load(LCCH-080P480-E0)
Efficiency vs. Load
Efficiency (%)
95%
90%
Vin=100
85%
Vin=120
Vin=200
Vin=230
Vin=277
80%
65%
70%
75%
80%
85%
90%
95%
100%
105%
Load (%)
PF vs. Load(LCCH-080P480-E0)
PF vs. Load
Power Factor
1.00
0.95
0.90
Vin=100
Vin=120
0.85
Vin=200
Vin=230
Vin=277
0.80
65%
70%
75%
80%
85%
90%
95%
100%
105%
Load (%)
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw
80W Power Supply
Constant Current Mode
80-LCCH Series
www.linkcom.com.tw For more information, please contact with: [email protected]
THD vs. Load(LCCH-080P480-E0)
THD vs. Load
30%
25%
THD (%)
20%
15%
Vin=100
10%
Vin=120
Vin=200
5%
Vin=230
Vin=277
0%
65%
70%
75%
80%
85%
90%
95%
100%
105%
Load(%)
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw