Coilcraft E3496-AL Common mode line choke Datasheet

Document 141-1
Common Mode Line Chokes – EE Styles
• Low cost
• 3 mm creepage and clearance from all terminations to the
core
• 3750 Vrms, one minute isolation between windings
• UL1446 Class B (130°C) Insulation System (UL File E83628)
• Industry-standard EE25 size
• Wide range of available inductances and current ratings
Coilcraft Designer’s Kit No. P402 contains samples
of eight standard EE and toroidal common mode line
chokes. To order, contact Coilcraft or purchase on-line at
buy.coilcraft.com.
Coilcraft common mode standard packages incorporate
several features to help meet the requirements of major
safety agencies. These include 2 mm thick center flanges
and 3 mm creepage and clearance from all terminations
to the core.
Common mode chokes are used to reduce AC line conducted interference produced by switching power supplies.
This configuration produces opposing magnetic fluxes in
the core that serve to cancel in-phase noise signals appearing across the AC line.
This mode allows much more filtering capability in a given
core size than would be possible using differential filtering
alone. Use of common mode chokes therefore reduces
component count as well as inductor size.
Combining both common and differential mode chokes
gives the power supply designer the added flexibility
required to adjust the filtering to meet FCC, VDE, and
other requirements as well as optimize the circuit for the
particular noise levels and frequencies produced by each
power supply design.
The Coilcraft packaging of common mode chokes allows
windings to be balanced within 1% and features the cost
effectiveness of standard EE core styles.
Schematic
2
Typical Application
2
4
4
0.005 µF
AC
input
0.1 µF
0.1 µF
0.005 µF
9
7
9
US +1-847-639-6400 [email protected]
UK +44-1236-730595 [email protected]
Taiwan +886-2-2264 3646 [email protected]
China +86-21-6218 8074 [email protected]
Singapore + 65-6484 8412 [email protected]
7
Document 141-1
Revised 04/20/12
© Coilcraft Inc. 2013
This product may not be used in medical or high
risk applications without prior Coilcraft approval.
Specification subject to change without notice.
Please check web site for latest information.
Document 141-2
Common Mode Line Chokes – EE Styles
Standard EE Line Chokes
Part
number
Current
rating1
DCR max2
(Ohms)
Inductance3
min
E3490-AL
E3491-AL
E3492-AL
E3493-AL
E3494-AL
E3495-AL
E3496-AL
E3497-AL
E3498-AL
500 mA
750 mA
1A
1¼ A
1½ A
2A
2½ A
3A
4A
0.980
0.390
0.270
0.190
0.105
0.069
0.044
0.029
0.016
9.9 mH
3.9 mH
2.9 mH
2.1 mH
1.1 mH
731 µH
468 µH
299 µH
168 µH
1. Based on 300 circular mils/Amp. Temperature rise is less than 10°C.
2. DCR is maximum per winding.
3. Per section. Typical values are approximately 30% higher than published
minimums.
4. Ambient temperature range –40°C to +85°C.
5. Electrical specifications at 25°C.
6. Parts in bold type are included in Coilcraft Designer’s Kit No. P402.
0.950
max
24,13
0.032
dia ref
0,813
0.15 ±0.030
3,81 ±0,762
0.40
10,16
0.155
ref
3,937
2
4
0.62 ±0.015
15,75 ±0,38
1.10
max
27,94
0.079
min
2,00
9
7
1.10 max
27,94
Weight:
Terminations:
19 – 33.8 g
Tin-silver over tin over copper
Standard EE Line Chokes – High Inductance
Part
number
Current
rating1
DCR max2
(Ohms)
Inductance3
min
E3499-AL
E3500-AL
E3501-AL
E3502-AL
E3503-AL
E3504-AL
E3505-AL
E3506-AL
E3507-AL
500 mA
750 mA
1A
1¼ A
1½ A
2A
2½ A
3A
4A
1.260
0.500
0.350
0.230
0.130
0.087
0.055
0.037
0.022
16.8 mH
6.6 mH
4.9 mH
3.6 mH
1.87 mH
1.24 mH
796 µH
508 µH
286 µH
1. Based on 300 circular mils/Amp. Temperature rise is less than 10°C.
2. DCR is maximum per winding.
3. Per section. Typical values are approximately 30% higher than published
minimums.
4. Ambient temperature range –40°C to +85°C.
5. Electrical specifications at 25°C.
1.20
max
30,48
0.032
dia ref
0,813
0.15 ±0.030
3,81 ±0,762
0.40
10,16
0.155
ref
3,937
2
4
0.62 ±0.015
15,75 ±0,38
1.10
max
27,94
0.079
min
2,00
9
7
1.10 max
27,94
For custom values or information on toroidal common mode line chokes,
please contact Coilcraft.
Weight:
Terminations:
19 – 33.8 g
Tin-silver over tin over copper
US +1-847-639-6400 [email protected]
UK +44-1236-730595 [email protected]
Taiwan +886-2-2264 3646 [email protected]
China +86-21-6218 8074 [email protected]
Singapore + 65-6484 8412 [email protected]
Document 141-2
Revised 04/20/12
© Coilcraft Inc. 2013
This product may not be used in medical or high
risk applications without prior Coilcraft approval.
Specification subject to change without notice.
Please check web site for latest information.
Similar pages