Product Folder Sample & Buy Support & Community Tools & Software Technical Documents INA220 SBOS459E – JUNE 2009 – REVISED JANUARY 2016 INA220 High- or Low-Side, Bidirectional Current and Power Monitor With Two-Wire Interface 1 Features 3 Description • • • • • The INA220 is a current shunt and power monitor with an I2C- or SMBUS-compatible interface. The INA220 monitors both shunt drop and supply voltage. A programmable calibration value, combined with an internal multiplier, enables direct readouts in amperes. An additional multiplying register calculates power in watts. The I2C- or SMBUS-compatible interface features 16 programmable addresses. The separate shunt input on the INA220 allows it to be used in systems with low-side sensing. 1 • • • High- or Low-Side Sensing Senses Bus Voltages from 0 V to 26 V Reports Current, Voltage, and Power 16 Programmable Addresses High Accuracy: 0.5% (Maximum) Over Temperature (INA220B) User-Programmable Calibration Fast (2.56-MHz) I2C- or SMBUS-Compatible Interface VSSOP-10 Package The INA220 is available in two grades: A and B. The B grade version has higher accuracy and higher precision specifications. 2 Applications • • • • • • • • The INA220 senses across shunts on buses that can vary from 0 to 26 V, useful for low-side sensing or CPU power supplies. The device uses a single 3- to 5.5-V supply, drawing a maximum of 1 mA of supply current. The INA220 operates from –40°C to 125°C. Servers Telecom Equipment Notebook Computers Power Management Battery Chargers Automotive Power Supplies Test Equipment Device Information(1) PART NUMBER INA220 PACKAGE VSSOP (10) BODY SIZE (NOM) 3.00 mm × 3.00 mm (1) For all available packages, see the orderable addendum at the end of the data sheet. General Load, Low- or High-Side Sensing Supply (0 to 26V) +3.3V to +5V CBYPASS 0.1µF HighSide Shunt Bus Voltage Input VS (Supply Voltage) INA220 × Load SDA Power Register 2 LowSide Shunt R2F V VIN+ Current Register ADC R1F CF I C-/SMBUSCompatible Interface SCL DATA CLK A0 A1 Voltage Register VIN- I GND 1 An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications, intellectual property matters and other important disclaimers. PRODUCTION DATA. INA220 SBOS459E – JUNE 2009 – REVISED JANUARY 2016 www.ti.com Table of Contents 1 2 3 4 5 6 7 8 Features .................................................................. Applications ........................................................... Description ............................................................. Revision History..................................................... Related Products ................................................... Pin Configuration and Functions ......................... Specifications......................................................... 1 1 1 2 3 3 4 7.1 7.2 7.3 7.4 7.5 7.6 7.7 4 4 4 4 5 6 7 Absolute Maximum Ratings ...................................... ESD Ratings.............................................................. Recommended Operating Conditions....................... Thermal Information .................................................. Electrical Characteristics........................................... Bus Timing Diagram Definitions................................ Typical Characteristics .............................................. Detailed Description .............................................. 9 8.1 Overview ................................................................... 9 8.2 Functional Block Diagram ......................................... 9 8.3 Feature Description................................................... 9 8.4 Device Functional Modes........................................ 10 8.5 Programming .......................................................... 11 8.6 Register Maps ......................................................... 17 9 Application and Implementation ........................ 24 9.1 Application Information............................................ 24 9.2 Typical Application .................................................. 24 10 Power Supply Recommendations ..................... 28 11 Layout................................................................... 28 11.1 Layout Guidelines ................................................. 28 11.2 Layout Example .................................................... 28 12 Device and Documentation Support ................. 29 12.1 12.2 12.3 12.4 12.5 Related Documentation......................................... Community Resources.......................................... Trademarks ........................................................... Electrostatic Discharge Caution ............................ Glossary ................................................................ 29 29 29 29 29 13 Mechanical, Packaging, and Orderable Information ........................................................... 29 4 Revision History NOTE: Page numbers for previous revisions may differ from page numbers in the current version. Changes from Revision D (September 2010) to Revision E Page • Added ESD Ratings table, Feature Description section, Device Functional Modes section, Application and Implementation section, Power Supply Recommendations section, Layout section, Device and Documentation Support section, and Mechanical, Packaging, and Orderable Information section ............................................................... 1 • Deleted Temperature Range parameters from Electrical Characteristics. ............................................................................. 6 Changes from Revision C (September, 2009) to Revision D Page • Changed High Accuracy bullet in Features from 1% to 0.5% for B-grade device.................................................................. 1 • Added new paragraph to Description regarding A- and B-grade versions of the device ....................................................... 1 • Added new row to Packaging Information table to show new B-grade device ...................................................................... 3 • Added B-grade columns in Electrical Characteristics for MIN, TYP and MAX values ........................................................... 5 • Changed Current Sense Gain Error over temperature specification from 10 ppm/°C to 1m%/°C ......................................... 5 • Added Configure/Measure/Calculate Example..................................................................................................................... 24 Changes from Revision B (June, 2009) to Revision C Page • Changed specified temperature range from –25°C to –40°C................................................................................................. 5 • Changed Offset Voltage (RTI) vs Temperature minimum specification from 0.1 μV/°C to 0.16 μV/°C ................................. 5 • Updated Typical Characteristics: Figure 3, Figure 4, Figure 5, Figure 6 ............................................................................... 7 • Updated Typical Characteristics: Figure 9, Figure 10 ............................................................................................................ 7 2 Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 INA220 www.ti.com SBOS459E – JUNE 2009 – REVISED JANUARY 2016 5 Related Products DEVICE DESCRIPTION INA209 Current/power monitor with watchdog, peak-hold, and fast comparator functions INA210, INA211, INA212, INA213, INA214 INA219 Zero-drift, low-cost, analog current shunt monitor series in small package Zero-drift, bidirectional current power monitor with two-wire interface 6 Pin Configuration and Functions DGS Package 10-PIN VSSOP Top View A1 1 10 IN+ A0 2 9 IN- NC 3 8 VBUS SDA 4 7 GND SCL 5 6 VS Pin Functions PIN NAME NO. I/O DESCRIPTION A1 1 Digital Input Address pin. Connect to GND, SCL, SDA, or VS. Table 1 shows pin settings and corresponding addresses. A0 2 Digital Input Address pin. Connect to GND, SCL, SDA, or VS. Table 1 shows pin settings and corresponding addresses. NC 3 — SDA 4 Digital I/O Serial bus data line SCL 5 Digital Input Serial bus clock line VS 6 Analog Power supply, 3 V to 5.5 V GND 7 Analog Ground VBUS 8 Analog Input Bus voltage input IN– 9 Analog Input Negative differential shunt voltage. Connect to negative side of shunt resistor. Bus voltage is measured from this pin to ground. IN+ 10 Analog Input Positive differential shunt voltage. Connect to positive side of shunt resistor. No internal connection Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 3 INA220 SBOS459E – JUNE 2009 – REVISED JANUARY 2016 www.ti.com 7 Specifications 7.1 Absolute Maximum Ratings over operating free-air temperature range (unless otherwise noted). (1) MIN VS MAX UNIT 6 V Supply voltage (2) Analog inputs Differential (VIN+) – (VIN–) IN+, IN– Common-mode (VIN+ + VIN-) / 2 –26 26 V –0.3 26 V VVBUS Voltage at VBUS pin –0.3 26 V VSDA Voltage at SDA pin GND – 0.3 6 V VSCL Voltage at SCL pin GND – 0.3 VS + 0.3 V 5 mA Input current into any pin Open-drain digital output current Operating temperature –40 TJ Junction temperature Tstg Storage temperature (1) (2) –65 10 mA 125 °C 150 °C 150 °C Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. IN+ and IN– may have a differential voltage of –26 to 26 V; however, the voltage at these pins must not exceed the range of –0.3 to 26 V. 7.2 ESD Ratings VALUE Electrostatic discharge V(ESD) (1) (2) Human body model (HBM), per ANSI/ESDA/JEDEC JS-001, all pins (1) ±4000 Charged device model (CDM), per JEDEC specification JESD22-C101, all pins (2) ±1000 Machine model (MM) ±150 UNIT V JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process. JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process. 7.3 Recommended Operating Conditions over operating free-air temperature range (unless otherwise noted) MIN NOM MAX UNIT VCM (VIN+ + VIN-) / 2 12 V VS Supply voltage 3.3 V TA Ambient temperature –25 85 ºC 7.4 Thermal Information INA220 THERMAL METRIC (1) DGS (VSSOP) UNIT 10 PINS RθJA Junction-to-ambient thermal resistance 165.4 °C/W RθJC(top) Junction-to-case (top) thermal resistance 53.2 °C/W RθJB Junction-to-board thermal resistance 86.6 °C/W ψJT Junction-to-top characterization parameter 6.4 °C/W ψJB Junction-to-board characterization parameter 85.0 °C/W (1) 4 For more information about traditional and new thermal metrics, see the Semiconductor and IC Package Thermal Metrics application report, SPRA953. Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 INA220 www.ti.com SBOS459E – JUNE 2009 – REVISED JANUARY 2016 7.5 Electrical Characteristics at TA = 25°C, VS = 3.3 V, VIN+ = 12 V, VSHUNT = (VIN+ – VIN–) = 32 mV, VVBUS = 12 V, PGA = /1, and BRNG (1) = 1, unless otherwise noted. TEST CONDITIONS INA220A MIN TYP INA220B MAX MIN TYP MAX UNIT INPUT Full-scale current sense (input) voltage range VSHUNT Bus voltage (input voltage) (2) Common-mode rejection versus power supply Current sense gain error 0 ±40 0 ±40 mV PGA = /2 0 ±80 0 ±80 mV PGA = /4 0 ±160 0 ±160 mV PGA = /8 0 ±320 0 ±320 mV BRNG = 1 0 32 0 32 BRNG = 0 0 16 0 16 VIN+ = 0 to 26 V VOS Offset Voltage, RTI (3) PGA = /1 PSRR 100 120 100 120 V V dB PGA = /1 ±10 ±100 ±10 ±50 (4) μV PGA = /2 ±20 ±125 ±20 ±75 (4) μV PGA = /4 ±30 ±150 ±30 ±75 (4) μV PGA = /8 ±40 ±200 ±40 ±100 (4) TA = –40°C to 85°C 0.16 0.16 μV/°C 10 10 μV/V ±40 ±40 1 1 m%/°C μA VS = 3 to 5.5 V TA = –40°C to 85°C μV m% IN+ pin input impedance Active mode 20 20 IN– pin input impedance Active mode 20 20 μA VBUS pin input impedance (5) Active mode 320 320 kΩ IN+ pin input leakage (6) Power-down mode 0.1 ±0.5 0.1 ±0.5 μA IN– pin input leakage (6) Power-down mode 0.1 ±0.5 0.1 ±0.5 μA DC ACCURACY ADC basic resolution 12 12 Shunt voltage 1-LSB step size 10 10 μV Bus voltage 1-LSB step size 4 4 mV ±0.2% Current measurement error over Temperature TA = –40°C to 85°C ±0.2% ±0.2% over Temperature TA = –40°C to 85°C ±0.5% ±0.2% ±1% Differential nonlinearity ±0.3% (4) ±0.5% (4) ±1% VBUS = 12 V Bus voltage measurement error ±0.5% bits ±0.5% ±1% ±0.1 ±0.1 LSB ADC TIMING ADC conversion time 12-bit 532 586 532 586 μs 11-bit 276 304 276 304 μs 10-bit 148 163 148 163 μs 9-bit 84 93 84 93 μs Minimum convert input low time 4 μs 4 SMBus SMBus timeout (7) (1) (2) (3) (4) (5) (6) (7) 28 35 28 35 ms BRNG is bit 13 of the Configuration Register 00h (see Figure 19). This parameter only expresses the full-scale range of the ADC scaling. In no event should more than 26 V be applied to this device. Referred-to-input (RTI) Indicates improved specifications of the INA220B. The input impedance of this pin may vary approximately ±15%. Input leakage is positive (current flowing into the pin) for the conditions shown at the top of the table. Negative leakage currents can occur under different input conditions. SMBus timeout in the INA220 resets the interface any time SCL or SDA is low for more than 28 ms. Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 5 INA220 SBOS459E – JUNE 2009 – REVISED JANUARY 2016 www.ti.com Electrical Characteristics (continued) at TA = 25°C, VS = 3.3 V, VIN+ = 12 V, VSHUNT = (VIN+ – VIN–) = 32 mV, VVBUS = 12 V, PGA = /1, and BRNG(1) = 1, unless otherwise noted. INA220A TEST CONDITIONS MIN INA220B TYP MAX MIN TYP MAX UNIT DIGITAL INPUTS (SDA as Input, SCL, A0, A1) Input capacitance 3 0 ≤ VIN ≤ VS Leakage input current 3 0.1 1 pF 0.1 1 μA V VIH input logic level 0.7 (VS) 6 0.7 (VS) 6 VIL input logic level –0.3 0.3 (VS) –0.3 0.3 (VS) Hysteresis 500 V 500 mV OPEN-DRAIN DIGITAL OUTPUTS (SDA) Logic 0 output level ISINK = 3 mA High-level output leakage current VOUT = VS 0.15 0.4 0.15 0.4 V 0.1 1 0.1 1 μA POWER SUPPLY Operating supply range 3 5.5 Quiescent current 3 5.5 V 0.7 1 0.7 1 mA Quiescent current, power-down mode 6 15 6 15 μA Power-on reset threshold 2 2 V 7.6 Bus Timing Diagram Definitions (1) FAST MODE MIN HIGH-SPEED MODE TYP MAX MIN 0.4 0.001 TYP UNIT MAX ƒ(SCL) SCL operating frequency 0.001 t(BUF) Bus free time between STOP and START condition 1300 160 ns t(HDSTA) Hold time after repeated START condition After this period, the first clock is generated. 600 160 ns t(SUSTA) Repeated START condition setup time 600 160 ns t(SUSTO) STOP condition setup time 600 160 t(HDDAT) Data hold time t(SUDAT) Data setup time 100 10 ns t(LOW) SCL clock LOW period 1300 250 ns t(HIGH) SCL clock HIGH period 600 60 ns tFDA Data fall time 300 150 ns tFCL Clock fall time 300 40 ns tRCL Clock rise time 300 40 ns tRCL Clock rise time for SCLK ≤ 100 kHz (1) 0 900 2.56 MHz ns 0 90 ns 1000 ns Values based on a statistical analysis of a one-time sample of devices. Minimum and maximum values are not ensured and not production tested. Condition: A0=A1=0. t(LOW) tF tR t(HDSTA) SCL t(HDSTA) t(HIGH) t(HDDAT) t(SUSTO) t(SUSTA) t(SUDAT) SDA t(BUF) P S S P Figure 1. Bus Timing Diagram 6 Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 INA220 www.ti.com SBOS459E – JUNE 2009 – REVISED JANUARY 2016 7.7 Typical Characteristics 0 100 -10 80 -20 60 -30 40 Offset (mV) Gain (dB) at TA = 25°C, VS = 3.3 V, VIN+ = 12 V, VSHUNT = (VIN+ – VIN–) = 32 mV, PGA = /1, and BRNG = 1, unless otherwise noted. -40 -50 -60 20 0 -20 -70 -40 -80 -60 -90 -80 -100 -100 1k 100 10 10k 100k 320mV Range 160mV Range 1M 80mV Range -50 0 -25 Input Frequency (Hz) Figure 2. Frequency Response 75 100 125 Figure 3. ADC Shunt Offset vs Temperature 45 160mV Range 320mV Range 60 40 35 40 Offset (mV) Gain Error (m%) 50 50 80 20 0 -40 25 Temperature (°C) 100 -20 40mV Range 80mV Range 40mV Range 30 25 20 -60 10 -80 5 16V Range 32V Range 15 0 -100 -50 -25 0 25 50 75 100 125 -50 -25 0 25 50 75 100 125 Temperature (°C) Temperature (°C) Figure 4. ADC Shunt Gain Error vs Temperature Figure 5. ADC Bus Voltage Offset vs Temperature 100 20 80 15 10 40 16V 20 INL (mV) Gain Error (m%) 60 0 -20 0 -5 32V -40 5 -60 -10 -80 -15 -100 -50 -25 0 25 50 75 100 125 -20 -0.4 Temperature (°C) -0.3 -0.2 -0.1 0 0.1 0.2 0.3 0.4 Input Voltage (V) Figure 6. ADC Bus Gain Error vs Temperature Figure 7. Integral Nonlinearity vs Input Voltage Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 7 INA220 SBOS459E – JUNE 2009 – REVISED JANUARY 2016 www.ti.com Typical Characteristics (continued) at TA = 25°C, VS = 3.3 V, VIN+ = 12 V, VSHUNT = (VIN+ – VIN–) = 32 mV, PGA = /1, and BRNG = 1, unless otherwise noted. 2.0 1.2 VS+ = 5V 1.0 1.0 VS = 5V 0.8 0.5 IQ (mA) Input Currents (mA) 1.5 VS+ = 3V 0 VS+ = 3V 0.6 VS = 3V 0.4 -0.5 0.2 -1.0 VS+ = 5V 0 -1.5 10 5 0 15 20 25 -50 30 -25 0 VIN- Voltage (V) 50 75 16 1.0 14 0.9 0.7 IQ (mA) 10 VS = 5V 8 6 VS = 3V 4 0.6 VS = 3V 0.5 0.4 0.3 0.2 2 0.1 0 0 -50 0 -25 25 50 75 100 1k 125 10k 100k 1M 10M SCL Frequency (Hz) Temperature (°C) Figure 10. Shutdown IQ vs Temperature Figure 11. Active IQ vs Two-Wire Clock Frequency 300 5 4 5V +Error 250 VS = 5V 3 3.3V +Error 2 200 1 IQ (mA) % Bus Voltage Error 125 VS = 5V 0.8 12 0 -1 150 100 -2 -3 50 5V -Error -4 VS = 3V 3.3V -Error 0 -5 0 8 100 Figure 9. Active IQ vs Temperature Figure 8. Input Currents With Large Differential Voltages (VIN+ at 12 V, Sweep Of VIN–) IQ (mA) 25 Temperature (°C) 1 2 3 4 5 24 25 26 1k 10k 100k 1M 10M VBUS (V) SCL Frequency (Hz) Figure 12. Total Percent Bus Voltage Error vs Supply Voltage Figure 13. Shutdown IQ vs Two-Wire Clock Frequency Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 INA220 www.ti.com SBOS459E – JUNE 2009 – REVISED JANUARY 2016 8 Detailed Description 8.1 Overview The INA220 is a digital current sense amplifier with an I2C- and SMBus-compatible interface. It provides digital current, voltage, and power readings necessary for accurate decision-making in precisely-controlled systems. Programmable registers allow flexible configuration for measurement resolution as well as continuous-versustriggered operation. Detailed register information appears at the end of this data sheet, beginning with Table 2. See Functional Block Diagram for a block diagram of the INA220 device. 8.2 Functional Block Diagram Power (1) Bus Voltage (1) ´ Shunt Voltage Channel Current (1) ADC Bus Voltage Channel Full-Scale Calibration (2) ´ Shunt Voltage (1) PGA (In Configuration Register) NOTES: (1) Read-only (2) Read/write Data Registers 8.3 Feature Description 8.3.1 Basic ADC Functions The two analog inputs to the INA220, IN+ and IN–, connect to a shunt resistor in the bus of interest. Bus voltage is measured at VBUS pin. The INA220 is typically powered by a separate supply from 3 to 5.5 V. The bus being sensed can vary from 0 to 26 V. It requires no special considerations for power-supply sequencing (for example, a bus voltage can be present with the supply voltage off, and vice-versa). The INA220 senses the small drop across the shunt for shunt voltage, and senses the voltage with respect to ground from VBUS pin for the bus voltage. When the INA220 is in the normal operating mode (that is, MODE bits of the Configuration register are set to 111), it continuously converts the shunt voltage up to the number set in the shunt voltage averaging function (Configuration register, SADC bits). The device then converts the bus voltage up to the number set in the bus voltage averaging (Configuration register, BADC bits). The Mode control in the Configuration register also permits selecting modes to convert only voltage or current, either continuously or in response to an event (triggered). All current and power calculations are performed in the background and do not contribute to conversion time; conversion times shown in Electrical Characteristics can be used to determine the actual conversion time. Power-down mode reduces the quiescent current and turns off current into the INA220 inputs, avoiding any supply drain. Full recovery from power-down requires 40 μs. ADC off mode (set by the Configuration register, MODE bits) stops all conversions. In triggered mode, writing any of the triggered convert modes into the Configuration register (even if the desired mode is already programmed into the register) triggers a single-shot conversion. Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 9 INA220 SBOS459E – JUNE 2009 – REVISED JANUARY 2016 www.ti.com Feature Description (continued) Although the INA220 can be read at any time, and the data from the last conversion remain available, the Conversion Ready bit (Status register, CNVR bit) is provided to help coordinate one-shot or triggered conversions. The Conversion Ready bit is set after all conversions, averaging, and multiplication operations are complete. The Conversion Ready bit clears under any of these conditions: • Writing to the Configuration register, except when configuring the MODE bits for power down or ADC off (disable) modes • Reading the Status register • Triggering a single-shot conversion with the convert pin 8.3.1.1 Power Measurement Current and bus voltage are converted at different points in time, depending on the resolution and averaging mode settings. For instance, when configured for 12-bit and 128-sample averaging, up to 68 ms in time between sampling these two values is possible. Again, these calculations are performed in the background and do not add to the overall conversion time. 8.3.1.2 PGA Function If larger full-scale shunt voltages are desired, the INA220 provides a PGA function that increases the full-scale range up to 2, 4, or 8 times (320 mV). Additionally, the bus voltage measurement has two full-scale ranges: 16 or 32 V. 8.3.1.3 Compatibility With TI Hot Swap Controllers The INA220 is designed for compatibility with hot swap controllers such the TI TPS2490. The TPS2490 uses a high-side shunt with a limit at 50 mV; the INA220 full-scale range of 40 mV enables the use of the same shunt for current sensing below this limit. When sensing is required at (or through) the 50-mV sense point of the TPS2490, the PGA of the INA220 can be set to /2 to provide an 80-mV full-scale range. 8.4 Device Functional Modes 8.4.1 Filtering and Input Considerations Measuring current is often noisy, and such noise can be difficult to define. The INA220 offers several options for filtering by choosing resolution and averaging in the Configuration register. These filtering options can be set independently for either voltage or current measurement. The internal ADC is based on a delta-sigma (ΔΣ) front-end with a 500-kHz (±30%) typical sampling rate. This architecture has good inherent noise rejection; however, transients that occur at or very close to the sampling rate harmonics can cause problems. Because these signals are at 1 MHz and higher, they can be dealt with by incorporating filtering at the input of the INA220. The high frequency enables the use of low-value series resistors on the filter for negligible effects on measurement accuracy. In general, filtering the INA220 input is only necessary if there are transients at exact harmonics of the 500-kHz (±30%) sampling rate (>1 MHz). Filter using the lowest possible series resistance and ceramic capacitor. TI recommends values of 0.1 to 1 μF. Figure 14 shows the INA220 with an additional filter added at the input. Overload conditions are another consideration for the INA220 inputs. The INA220 inputs are specified to tolerate 26 V across the inputs. A large differential scenario might be a short to ground on the load side of the shunt. This type of event can result in full power-supply voltage across the shunt (as long the power supply or energy storage capacitors support it). It must be remembered that removing a short to ground can result in inductive kickbacks that could exceed the 26-V differential and common-mode rating of the INA220. Inductive kickback voltages are best dealt with by Zener-type transient-absorbing devices combined with sufficient energy storage capacitance. 10 Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 INA220 www.ti.com SBOS459E – JUNE 2009 – REVISED JANUARY 2016 Device Functional Modes (continued) In applications that do not have large energy storage electrolytics on one or both sides of the shunt, an input overstress condition may result from an excessive dV/dt of the voltage applied to the input. A hard physical short is the most likely cause of this event, particularly in applications with no large electrolytics present. This problem occurs because an excessive dV/dt can activate the ESD protection in the INA220 in systems where large currents are available. Testing has demonstrated that the addition of 10-Ω resistors in series with each input of the INA220 sufficiently protects the inputs against dV/dt failure up to the 26-V rating of the INA220. These resistors have no significant effect on accuracy. RSHUNT Load Supply RFILTER 10Ω RFILTER 10Ω Supply Voltage 3.3V Supply VBUS 0.1µF to 1µF Ceramic Capacitor VIN+ VIN- VS INA220 × Power Register Data (SDA) Clock (SCL) 2 Current Register ADC I C-/SMBUS Compatible Interface A0 A1 Voltage Register GND Figure 14. INA220 With Input Filtering 8.5 Programming 8.5.1 Programming the INA220 Calibration Register Register Details shows the default power-up states of the registers. These registers are volatile, and if programmed to anything other than default values, they must be reprogrammed at every device power-up. The Calibration Register is calculated based on Equation 1. This equation includes the term Current_LSB, which is the programmed value for the LSB for the Current Register (04h). The Current_LSB value is used to convert the value in the Current Register (04h) to the actual current in amperes. The highest resolution for the Current Register (04h) can be obtained by using the smallest allowable Current_LSB based on the maximum expected current as shown in Equation 2. While this value yields the highest resolution, it is common to select a value for the Current_LSB to the nearest round number above this value to simplify the conversion of the Current Register (04h) and Power Register (03h) to amperes and watts respectively. The RSHUNT term is the value of the external shunt used to develop the differential voltage across the input pins. The Power Register (03h) is internally set to be 20 times the programmed Current_LSB (see Equation 3). 0.04096 Cal = trunc Current_LSB ´ R SHUNT where • • 0.04096 is an internal fixed value used to ensure scaling is maintained properly Current_LSB is the programmed value for the LSB for the Current Register (04h) Current _ LSB = (1) Maximum Expected Current 215 Power_LSB = 20 Current_LSB (2) (3) Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 11 INA220 SBOS459E – JUNE 2009 – REVISED JANUARY 2016 www.ti.com Programming (continued) Shunt voltage is calculated by multiplying the Shunt Voltage Register contents with the Shunt Voltage LSB of 10 μV. The Bus Voltage register bits are not right-aligned. To compute the value of the Bus Voltage, Bus Voltage Register contents must be shifted right by three bits. This shift puts the BD0 bit in the LSB position so that the contents can be multiplied by the Bus Voltage LSB of 4-mV to compute the bus voltage measured by the device. After programming the Calibration Register, the value expected in the Current Register (04h) can be calculated by multiplying the Shunt Voltage register contents by the Calibration Register and then dividing by 4096 as shown in Equation 4. To obtain a value in amperes, the Current register value is multiplied by the programmed Current_LSB. Shunt Voltage Re gister ´ Calibration Re gister Current Register = 4096 (4) The value expected in the Power register (03h) can be calculated by multiplying the Current register value by the Bus Voltage register value and then dividing by 5000 as shown in Equation 5. Power Register content is multiplied by Power LSB which is 20 times the Current_LSB for a power value in watts. Current Re gister ´ Bus Voltage Re gister Power Register = 5000 (5) 8.5.2 Programming the INA220 Power Measurement Engine 8.5.2.1 Calibration Register and Scaling The Calibration register makes it possible to set the scaling of the Current and Power registers to whatever values are most useful for a given application. One strategy may be to set the Calibration register such that the largest possible number is generated in the Current register or Power register at the expected full-scale point; this approach yields the highest resolution. The Calibration register can also be selected to provide values in the Current and Power registers that either provide direct decimal equivalents of the values being measured, or yield a round LSB number. After these choices have been made, the Calibration register also offers possibilities for end-user system-level calibration, where the value is adjusted slightly to cancel total system error. After determining the exact current by using an external ammeter, the value of the Calibration Register can then be adjusted based on the measured current result of the INA220 to cancel the total system error as shown in Equation 6. Corrected_Full_Scale_Cal = trunc Cal ´ MeasShuntCurrent INA220_Current (6) 8.5.3 Simple Current Shunt Monitor Usage (No Programming Necessary) The INA220 can be used without any programming if it is only necessary to read a shunt voltage drop and bus voltage with the default 12-bit resolution, 320-mV shunt full-scale range (PGA = /8), 32-V bus full-scale range, and continuous conversion of shunt and bus voltage. Without programming, current is measured by reading the shunt voltage. The Current register and Power register are only available if the Calibration register contains a programmed value. 8.5.4 Bus Overview The INA220 offers compatibility with both I2C and SMBus interfaces. The I2C and SMBus protocols are essentially compatible with one another. The I2C interface is used throughout this data sheet as the primary example, with SMBus protocol specified only when a difference between the two systems is being addressed. Two lines, SCL and SDA, connect the INA220 to the bus. Both SCL and SDA are open-drain connections. The device that initiates the transfer is called a master, and the devices controlled by the master are slaves. The bus must be controlled by a master device that generates the serial clock (SCL), controls the bus access, and generates START and STOP conditions. 12 Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 INA220 www.ti.com SBOS459E – JUNE 2009 – REVISED JANUARY 2016 Programming (continued) To address a specific device, the master initiates a START condition by pulling the data signal line (SDA) from a high to a low logic level while SCL is high. All slaves on the bus shift in the slave address byte on the rising edge of SCL, with the last bit indicating whether a read or write operation is intended. During the ninth clock pulse, the slave being addressed responds to the master by generating an Acknowledge and pulling SDA low. Data transfer is then initiated and eight bits of data are sent, followed by an Acknowledge bit. During data transfer, SDA must remain stable while SCL is high. Any change in SDA while SCL is high is interpreted as a START or STOP condition. After all data have been transferred, the master generates a STOP condition, indicated by pulling SDA from low to high while SCL is high. The INA220 includes a 28-ms timeout on its interface to prevent locking up an SMBus. 8.5.4.1 Serial Bus Address To communicate with the INA220, the master must first address slave devices through a slave address byte. The slave address byte consists of seven address bits, and a direction bit indicating the intent of executing a read or write operation. The INA220 has two address pins, A0 and A1. Table 1 describes the pin logic levels for each of the 16 possible addresses. The state of pins A0 and A1 is sampled on every bus communication and should be set before any activity on the interface occurs. The address pins are read at the start of each communication event. Table 1. INA220 Address Pins and Slave Addresses A1 A0 SLAVE ADDRESS GND GND 1000000 GND VS 1000001 GND SDA 1000010 GND SCL 1000011 VS GND 1000100 VS VS 1000101 VS SDA 1000110 VS SCL 1000111 SDA GND 1001000 SDA VS 1001001 SDA SDA 1001010 SDA SCL 1001011 SCL GND 1001100 SCL VS 1001101 SCL SDA 1001110 SCL SCL 1001111 8.5.4.2 Serial Interface The INA220 operates only as a slave device on the I2C bus and SMBus. Connections to the bus are made by the open-drain I/O lines SDA and SCL. The SDA and SCL pins feature integrated spike suppression filters and Schmitt triggers to minimize the effects of input spikes and bus noise. The INA220 supports the transmission protocol for fast (1-kHz to 400-kHz) and high-speed (1-kHz to 2.56-MHz) modes. All data bytes are transmitted most significant byte first. 8.5.5 Writing to and Reading from the INA220 Accessing a particular register on the INA220 is accomplished by writing the appropriate value to the register pointer. Refer to Table 2 for a complete list of registers and corresponding addresses. The value for the register pointer, as shown in Figure 18, is the first byte transferred after the slave address byte with the R/W bit LOW. Every write operation to the INA220 requires a value for the register pointer. Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 13 INA220 SBOS459E – JUNE 2009 – REVISED JANUARY 2016 www.ti.com Writing to a register begins with the first byte transmitted by the master. This byte is the slave address, with the R/W bit LOW. The INA220 then acknowledges receipt of a valid address. The next byte transmitted by the master is the address of the register to which data will be written. This register address value updates the register pointer to the desired register. The next two bytes are written to the register addressed by the register pointer. The INA220 acknowledges receipt of each data byte. The master may terminate data transfer by generating a START or STOP condition. When reading from the INA220, the last value stored in the register pointer by a write operation determines which register is read during a read operation. To change the register pointer for a read operation, a new value must be written to the register pointer. This write is accomplished by issuing a slave address byte with the R/W bit LOW, followed by the register pointer byte. No additional data are required. The master then generates a START condition and sends the slave address byte with the R/W bit HIGH to initiate the read command. The next byte is transmitted by the slave and is the most significant byte of the register indicated by the register pointer. This byte is followed by an Acknowledge from the master; then the slave transmits the least significant byte. The master acknowledges receipt of the data byte. The master may terminate data transfer by generating a Not Acknowledge after receiving any data byte, or generating a START or STOP condition. If repeated reads from the same register are desired, it is not necessary to continually send the register pointer bytes; the INA220 retains the register pointer value until it is changed by the next write operation. Figure 15 and Figure 16 show write and read operation timing diagrams, respectively. Note that register bytes are sent most-significant byte first, followed by the least significant byte. Figure 17 shows the timing diagram for the SMBus Alert response operation. Figure 18 shows a typical register pointer configuration. 14 Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 INA220 www.ti.com SBOS459E – JUNE 2009 – REVISED JANUARY 2016 1 9 1 9 1 9 1 9 SCL SDA 1 0 0 A3 A2 A1 A0 R/W Start By Master P7 P6 P5 P4 P3 P2 P1 ACK By INA220 Frame 1 Two-Wire Slave Address Byte P0 D15 D14 D13 D12 D11 D10 D9 D8 (1) D7 D6 D5 D4 D3 D2 D1 D0 ACK By INA220 ACK By INA220 Frame 2 Register Pointer Byte ACK By INA220 Frame 3 Data MSByte Stop By Master Frame 4 Data LSByte NOTE (1): The value of the Slave Address Byte is determined by the settings of the A0 and A1 pins. Refer to Table 1. Figure 15. Timing Diagram for Write Word Format 1 9 1 9 1 9 SCL SDA 1 0 0 A3 A2 A1 A0 R/W Start By Master D15 D14 ACK By INA220 Frame 1 Two-Wire Slave Address Byte (1) D13 D12 D11 D10 D9 From INA220 Frame 2 Data MSByte D7 D8 D6 ACK By Master (2) D5 D4 D3 D2 D1 From INA220 D0 No ACK By Master Frame 3 Data LSByte (3) Stop (2) NOTES: (1) The value of the Slave Address Byte is determined by the settings of the A0 and A1 pins. Refer to Table 1. (2) Read data is from the last register pointer location. If a new register is desired, the register pointer must be updated. See Figure 19. (3) ACK by Master can also be sent. Figure 16. Timing Diagram for Read Word Format Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 15 INA220 SBOS459E – JUNE 2009 – REVISED JANUARY 2016 www.ti.com ALERT 1 9 1 9 SCL SDA 0 0 0 1 1 0 0 1 R/W Start By Master 0 0 A3 A2 ACK By INA220 A1 A0 0 From INA220 Frame 1 SMBus ALERT Response Address Byte Frame 2 Slave Address Byte NACK By Master Stop By Master (1) NOTE (1): The value of the Slave Address Byte is determined by the settings of the A0 and A1 pins. Refer to Table 1. Figure 17. Timing Diagram for SMBus Alert 1 9 1 9 SCL ¼ SDA 1 0 0 A3 A2 A1 A0 R/W Start By Master P7 P6 P5 P4 P3 P2 P1 ACK By INA220 Frame 1 Two-Wire Slave Address Byte (1) P0 Stop ACK By INA220 Frame 2 Register Pointer Byte NOTE (1): The value of the Slave Address Byte is determined by the settings of the A0 and A1 pins. Refer to Table 1. Figure 18. Typical Register Pointer Set 16 Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 INA220 www.ti.com SBOS459E – JUNE 2009 – REVISED JANUARY 2016 8.5.5.1 High-Speed Two-Wire Mode When the bus is idle, both the SDA and SCL lines are pulled high by the pullup devices. The master generates a start condition followed by a valid serial byte containing high-speed (HS) master code 00001XXX. This transmission is made in fast (400 kbps) or standard (100 kbps) (F/S) mode at no more than 400 kbps. The INA220 does not acknowledge the HS master code, but does recognize it and switches its internal filters to support 2.56-Mbps operation. The master then generates a repeated start condition (a repeated start condition has the same timing as the start condition). After this repeated start condition, the protocol is the same as F/S mode, except that transmission speeds up to 2.56 Mbps are allowed. Instead of using a stop condition, repeated start conditions should be used to secure the bus in HS-mode. A STOP condition ends the HS-mode and switches all the internal filters of the INA220 to support the F/S mode. See Bus Timing Diagram Definitions (1) and Figure 1 for timing. 8.5.5.2 Power-Up Conditions Power-up conditions apply to a software reset through the RST bit (bit 15) in the Configuration register, or the I2C bus General Call Reset. 8.6 Register Maps 8.6.1 Register Information The INA220 uses a bank of registers for holding configuration settings, measurement results, and status information. Table 2 summarizes the INA220 registers; Functional Block Diagram illustrates the registers. Register contents are updated 4 μs after completion of the write command. Therefore, a 4-μs delay is required between completion of a write to a given register and a subsequent read of that register (without changing the pointer) when using SCL frequencies in excess of 1 MHz. Table 2. Summary of Register Set POINTER ADDRESS REGISTER NAME FUNCTION HEX (1) (1) (2) POWER-ON RESET TYPE (1) BINARY HEX 00111001 10011111 399F R/W Shunt voltage — R Bus voltage — R 00 Configuration All-register reset, settings for bus voltage range, PGA gain, ADC resolution/averaging. 01 Shunt voltage Shunt voltage measurement data. 02 Bus voltage 03 Power (2) Power measurement data. 00000000 00000000 0000 R 04 Current (2) Contains the value of the current flowing through the shunt resistor. 00000000 00000000 0000 R 05 Calibration Sets full-scale range and LSB of current and power measurements. Overall system calibration. 00000000 00000000 0000 R/W Bus voltage measurement data. Values based on a statistical analysis of a one-time sample of devices. Minimum and maximum values are not ensured and not production tested. Condition: A0=A1=0. Type: R = Read only, R/W = Read/Write. The Power register and Current register default to 0 because the Calibration register defaults to 0, yielding a zero current value until the Calibration register is programmed. Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 17 INA220 SBOS459E – JUNE 2009 – REVISED JANUARY 2016 www.ti.com 8.6.2 Register Details All INA220 registers 16-bit registers are actually two 8-bit bytes through the I2C- or SMBUS-compatible interface. 8.6.2.1 Configuration Register (address = 00h) [reset = 399Fh] Figure 19. Configuration Register 15 14 13 12 11 RST — BRNG PG1 PG0 R/W0 R/W0 R/W-1 R/W-1 R/W-1 10 BADC 4 9 BADC 3 8 BADC 2 7 BADC 1 6 SADC 4 5 SADC 3 4 SADC 2 3 SADC 1 2 MODE 3 1 MODE 2 0 MODE 1 R/W-0 R/W-0 R/W-1 R/W-1 R/W-0 R/W-0 R/W-1 R/W-1 R/W-1 R/W-1 R/W-1 LEGEND: R/W = Read/Write; R = Read only; -n = value after reset RST: Reset Bit Bit 15 Setting this bit to 1 generates a system reset that is the same as power-on reset. Resets all registers to default values; this bit self-clears. BRNG: Bus Voltage Range Bit 13 0 = 16-V FSR 1 = 32-V FSR (default value) PG: PGA (Shunt Voltage Only) Bits 11, 12 Sets PGA gain and range. Note that the PGA defaults to ÷8 (320-mV range). Table 3 shows the gain and range for the various product gain settings. Table 3. PG Bit Settings [12:11] (1) (1) PG1 PG0 GAIN RANGE 0 0 1 ±40 mV 0 1 /2 ±80 mV 1 0 /4 ±160 mV 1 1 /8 ±320 mV Shaded values are default. BADC: BADC Bus ADC Resolution/Averaging Bits 7–10 These bits adjust the Bus ADC resolution (9-, 10-, 11-, or 12-bit) or set the number of samples used when averaging results for the Bus Voltage Register (02h). SADC: SADC Shunt ADC Resolution/Averaging Bits 3–6 These bits adjust the Shunt ADC resolution (9-, 10-, 11-, or 12-bit) or set the number of samples used when averaging results for the Shunt Voltage Register (01h). BADC (Bus) and SADC (Shunt) ADC resolution/averaging and conversion time settings are shown in Table 4. Table 4. ADC Settings (SADC [6:3], BADC [10:7]) (1) (1) (2) 18 ADC4 ADC3 ADC2 ADC1 Mode/Samples 0 X (2) 0 0 9-bit Conversion Time 84 μs 0 X (2) 0 1 10-bit 148 μs 0 X (2) 1 0 11-bit 276 μs 0 X (2) 1 1 12-bit 532 μs 1 0 0 0 12-bit 532 μs 1 0 0 1 2 1.06 ms 1 0 1 0 4 2.13 ms 1 0 1 1 8 4.26 ms 1 1 0 0 16 8.51 ms 1 1 0 1 32 17.02 ms Shaded values are default. X = Don't care Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 INA220 www.ti.com SBOS459E – JUNE 2009 – REVISED JANUARY 2016 Table 4. ADC Settings (SADC [6:3], BADC [10:7])() (continued) ADC4 ADC3 ADC2 ADC1 Mode/Samples Conversion Time 1 1 1 0 64 34.05 ms 1 1 1 1 128 68.10 ms MODE: Operating Mode Bits 0–2 Selects continuous, triggered, or power-down mode of operation. These bits default to continuous shunt and bus measurement mode. The mode settings are shown in Table 5. Table 5. Mode Settings [2:0] (1) (1) MODE3 MODE2 MODE1 0 0 0 Power-down MODE 0 0 1 Shunt voltage, triggered 0 1 0 Bus voltage, triggered 0 1 1 Shunt and bus, triggered 1 0 0 ADC off (disabled) 1 0 1 Shunt voltage, continuous 1 1 0 Bus voltage, continuous 1 1 1 Shunt and bus, continuous Shaded values are default. 8.6.3 Data Output Registers 8.6.3.1 Shunt Voltage Register (address = 01h) The Shunt Voltage register stores the current shunt voltage reading, VSHUNT. Shunt Voltage register bits are shifted according to the PGA setting selected in the Configuration register (00h). When multiple sign bits are present, they are all the same value. Negative numbers are represented in 2's complement format. Generate the 2's complement of a negative number by complementing the absolute value binary number and adding 1. Extend the sign, denoting a negative number by setting the MSB = 1. Extend the sign to any additional sign bits to form the 16-bit word. Example: For a value of VSHUNT = –320 mV: 1. Take the absolute value (include accuracy to 0.01 mV) → 320.00 2. Translate this number to a whole decimal number → 32000 3. Convert it to binary → 111 1101 0000 0000 4. Complement the binary result : 000 0010 1111 1111 5. Add 1 to the complement to create the 2's-complement formatted result → 000 0011 0000 0000 6. Extend the sign and create the 16-bit word: 1000 0011 0000 0000 = 8300h (Remember to extend the sign to all sign-bits, as necessary based on the PGA setting.) At PGA = /8, full-scale range = ±320 mV (decimal = 32000). For VSHUNT = +320 mV, Value = 7D00h; For VSHUNT = –320 mV, Value =8300h; and LSB = 10 μV. Figure 20. Shunt Voltage Register at PGA = /8 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 SD14_ SD13_ SD12_ SD11_ SD10_ SIGN SD9_8 SD8_8 SD7_8 SD6_8 SD5_8 SD4_8 SD3_8 SD2_8 SD1_8 SD0_8 8 8 8 8 8 At PGA = /4, full-scale range = ±160 mV (decimal = 16000). For VSHUNT = +160 mV, Value = 3E80h; For VSHUNT = –160 mV, Value = C180h; and LSB = 10 μV. Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 19 INA220 SBOS459E – JUNE 2009 – REVISED JANUARY 2016 www.ti.com Figure 21. Shunt Voltage Register at PGA = /4 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 SD13_ SD12_ SD11_ SD10_ SIGN SIGN SD9_4 SD8_4 SD7_4 SD6_4 SD5_4 SD4_4 SD3_4 SD2_4 SD1_4 SD0_4 4 4 4 4 At PGA = /2, full-scale range = ±80 mV (decimal = 8000). For VSHUNT = +80 mV, Value = 1F40h; For VSHUNT = –80 mV, Value = E0C0h; and LSB = 10 μV. Figure 22. Shunt Voltage Register at PGA = /2 15 14 13 12 SD12_ SIGN SIGN SIGN 2 11 SD11_ 2 10 SD10_ 2 9 8 7 6 5 4 3 2 1 0 SD9_2 SD8_2 SD7_2 SD6_2 SD5_2 SD4_2 SD3_2 SD2_2 SD1_2 SD0_2 At PGA = /1, full-scale range = ±40 mV (decimal = 4000). For VSHUNT = +40 mV, Value = 0FA0h; For VSHUNT = –40 mV, Value = F060h; and LSB = 10 μV. Figure 23. Shunt Voltage Register at PGA = /1 15 14 13 12 SIGN SIGN SIGN SIGN 20 11 10 9 8 7 6 5 4 3 2 1 0 SD11_ SD10_ SD9_1 SD8_1 SD7_1 SD6_1 SD5_1 SD4_1 SD3_1 SD2_1 SD1_1 SD0_1 1 1 Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 INA220 www.ti.com SBOS459E – JUNE 2009 – REVISED JANUARY 2016 Table 6. Shunt Voltage Register Format (1) (1) VSHUNT Reading (mV) Decimal Value PGA = /8 (D15:D0) PGA = /4 (D15:D0) PGA = /2 (D15:D0) PGA = /1 (D15:D0) 320.02 32002 0111 1101 0000 0000 0011 1110 1000 0000 0001 1111 0100 0000 0000 1111 1010 0000 320.01 32001 0111 1101 0000 0000 0011 1110 1000 0000 0001 1111 0100 0000 0000 1111 1010 0000 320.00 32000 0111 1101 0000 0000 0011 1110 1000 0000 0001 1111 0100 0000 0000 1111 1010 0000 319.99 31999 0111 1100 1111 1111 0011 1110 1000 0000 0001 1111 0100 0000 0000 1111 1010 0000 319.98 31998 0111 1100 1111 1110 0011 1110 1000 0000 0001 1111 0100 0000 0000 1111 1010 0000 160.02 16002 0011 1110 1000 0010 0011 1110 1000 0000 0001 1111 0100 0000 0000 1111 1010 0000 160.01 16001 0011 1110 1000 0001 0011 1110 1000 0000 0001 1111 0100 0000 0000 1111 1010 0000 160.00 16000 0011 1110 1000 0000 0011 1110 1000 0000 0001 1111 0100 0000 0000 1111 1010 0000 159.99 15999 0011 1110 0111 1111 0011 1110 0111 1111 0001 1111 0100 0000 0000 1111 1010 0000 159.98 15998 0011 1110 0111 1110 0011 1110 0111 1110 0001 1111 0100 0000 0000 1111 1010 0000 80.02 8002 0001 1111 0100 0010 0001 1111 0100 0010 0001 1111 0100 0000 0000 1111 1010 0000 80.01 8001 0001 1111 0100 0001 0001 1111 0100 0001 0001 1111 0100 0000 0000 1111 1010 0000 80.00 8000 0001 1111 0100 0000 0001 1111 0100 0000 0001 1111 0100 0000 0000 1111 1010 0000 79.99 7999 0001 1111 0011 1111 0001 1111 0011 1111 0001 1111 0011 1111 0000 1111 1010 0000 79.98 7998 0001 1111 0011 1110 0001 1111 0011 1110 0001 1111 0011 1110 0000 1111 1010 0000 40.02 4002 0000 1111 1010 0010 0000 1111 1010 0010 0000 1111 1010 0010 0000 1111 1010 0000 40.01 4001 0000 1111 1010 0001 0000 1111 1010 0001 0000 1111 1010 0001 0000 1111 1010 0000 40.00 4000 0000 1111 1010 0000 0000 1111 1010 0000 0000 1111 1010 0000 0000 1111 1010 0000 39.99 3999 0000 1111 1001 1111 0000 1111 1001 1111 0000 1111 1001 1111 0000 1111 1001 1111 39.98 3998 0000 1111 1001 1110 0000 1111 1001 1110 0000 1111 1001 1110 0000 1111 1001 1110 0.02 2 0000 0000 0000 0010 0000 0000 0000 0010 0000 0000 0000 0010 0000 0000 0000 0010 0.01 1 0000 0000 0000 0001 0000 0000 0000 0001 0000 0000 0000 0001 0000 0000 0000 0001 0 0 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 –0.01 –1 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 –0.02 –2 1111 1111 1111 1110 1111 1111 1111 1110 1111 1111 1111 1110 1111 1111 1111 1110 –39.98 –3998 1111 0000 0110 0010 1111 0000 0110 0010 1111 0000 0110 0010 1111 0000 0110 0010 –39.99 –3999 1111 0000 0110 0001 1111 0000 0110 0001 1111 0000 0110 0001 1111 0000 0110 0001 –40.00 –4000 1111 0000 0110 0000 1111 0000 0110 0000 1111 0000 0110 0000 1111 0000 0110 0000 –40.01 –4001 1111 0000 0101 1111 1111 0000 0101 1111 1111 0000 0101 1111 1111 0000 0110 0000 –40.02 –4002 1111 0000 0101 1110 1111 0000 0101 1110 1111 0000 0101 1110 1111 0000 0110 0000 –79.98 –7998 1110 0000 1100 0010 1110 0000 1100 0010 1110 0000 1100 0010 1111 0000 0110 0000 –79.99 –7999 1110 0000 1100 0001 1110 0000 1100 0001 1110 0000 1100 0001 1111 0000 0110 0000 –80.00 –8000 1110 0000 1100 0000 1110 0000 1100 0000 1110 0000 1100 0000 1111 0000 0110 0000 –80.01 –8001 1110 0000 1011 1111 1110 0000 1011 1111 1110 0000 1100 0000 1111 0000 0110 0000 –80.02 –8002 1110 0000 1011 1110 1110 0000 1011 1110 1110 0000 1100 0000 1111 0000 0110 0000 –159.98 –15998 1100 0001 1000 0010 1100 0001 1000 0010 1110 0000 1100 0000 1111 0000 0110 0000 –159.99 –15999 1100 0001 1000 0001 1100 0001 1000 0001 1110 0000 1100 0000 1111 0000 0110 0000 –160.00 –16000 1100 0001 1000 0000 1100 0001 1000 0000 1110 0000 1100 0000 1111 0000 0110 0000 –160.01 –16001 1100 0001 0111 1111 1100 0001 1000 0000 1110 0000 1100 0000 1111 0000 0110 0000 –160.02 –16002 1100 0001 0111 1110 1100 0001 1000 0000 1110 0000 1100 0000 1111 0000 0110 0000 –319.98 –31998 1000 0011 0000 0010 1100 0001 1000 0000 1110 0000 1100 0000 1111 0000 0110 0000 –319.99 –31999 1000 0011 0000 0001 1100 0001 1000 0000 1110 0000 1100 0000 1111 0000 0110 0000 –320.00 –32000 1000 0011 0000 0000 1100 0001 1000 0000 1110 0000 1100 0000 1111 0000 0110 0000 –320.01 –32001 1000 0011 0000 0000 1100 0001 1000 0000 1110 0000 1100 0000 1111 0000 0110 0000 –320.02 –32002 1000 0011 0000 0000 1100 0001 1000 0000 1110 0000 1100 0000 1111 0000 0110 0000 Out-of-range values are shown in gray shading. Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 21 INA220 SBOS459E – JUNE 2009 – REVISED JANUARY 2016 www.ti.com 8.6.3.2 Bus Voltage Register (address = 02h) The Bus Voltage register stores the most recent bus voltage reading, VBUS. At full-scale range = 32 V (decimal = 8000, hex = 1F40), and LSB = 4 mV. Figure 24. Bus Voltage Register (BRNG = 1) 15 BD12 14 BD11 13 BD10 12 BD9 11 BD8 10 BD7 9 BD6 8 BD5 7 BD4 6 BD3 5 BD2 4 BD1 3 BD0 2 — 1 CNVR 0 OVF 3 BD0 2 — 1 CNVR 0 OVF At full-scale range = 16 V (decimal = 4000, hex = 0FA0), and LSB = 4 mV. Figure 25. Bus Voltage Register (BRNG = 0) 15 0 14 BD11 13 BD10 12 BD9 11 BD8 10 BD7 9 BD6 8 BD5 7 BD4 6 BD3 5 BD2 4 BD1 CNVR: Conversion Ready Bit 1 Although the data from the last conversion can be read at any time, the INA220 Conversion Ready bit (CNVR) indicates when data from a conversion is available in the data output registers. The CNVR bit is set after all conversions, averaging, and multiplications are complete. CNVR will clear under the following conditions: 1.) Writing a new mode into the Operating Mode bits in the Configuration Register (except for Power-Down or Disable) 2.) Reading the Power Register OVF: Math Overflow Flag Bit 0 The Math Overflow Flag (OVF) is set when the Power or Current calculations are out of range. It indicates that current and power data may be meaningless. 8.6.3.3 Power Register (address = 03h) [reset = 00h] Full-scale range and LSB are set by the Calibration register. See Programming the INA220 Calibration Register. Figure 26. Power Register 15 PD15 R-0 14 PD14 R-0 13 PD13 R-0 12 PD12 R-0 11 PD11 R-0 10 PD10 R-0 9 PD9 R-0 8 PD8 R-0 7 PD7 R-0 6 PD6 R-0 5 PD5 R-0 4 PD4 R-0 3 PD3 R-0 2 PD2 R-0 1 PD1 R-0 0 PD0 R-0 LEGEND: R/W = Read/Write; R = Read only; -n = value after reset The Power register records power in watts by multiplying the values of the current with the value of the bus voltage according to the Equation 5: 8.6.3.4 Current Register (address = 04h) [reset =00h] Full-scale range and LSB depend on the value entered in the Calibration register. See Programming the INA220 Calibration Register. Negative values are stored in 2's complement format. Figure 27. Current Register 15 CSIGN R-0 14 CD14 R-0 13 CD13 R-0 12 CD12 R-0 11 CD11 R-0 10 CD10 R-0 9 CD9 R-0 8 CD8 R-0 7 CD7 R-0 6 CD6 R-0 5 CD5 R-0 4 CD4 R-0 3 CD3 R-0 2 CD2 R-0 1 CD1 R-0 0 CD0 R-0 LEGEND: R/W = Read/Write; R = Read only; -n = value after reset 22 Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 INA220 www.ti.com SBOS459E – JUNE 2009 – REVISED JANUARY 2016 The value of the Current register is calculated by multiplying the value in the Shunt Voltage register with the value in the Calibration register according to the Equation 4. 8.6.4 Calibration Register 8.6.4.1 Calibration Register (address = 05h) [reset = 00h] Current and power calibration are set by bits FS15 to FS1 of the Calibration register. Note that bit FS0 is not used in the calculation. This register sets the current that corresponds to a full-scale drop across the shunt. Fullscale range and the LSB of the current and power measurement depend on the value entered in this register. See the Programming the INA220 Calibration Register. This register is suitable for use in overall system calibration. Note that the 0 POR values are all default. Figure 28. Calibration Register (1) 15 FS15 R/W-0 14 FS14 R/W-0 13 FS13 R/W-0 12 FS12 R/W-0 11 FS11 R/W-0 10 FS10 R/W-0 9 FS9 R/W-0 8 FS8 R/W-0 7 FS7 R/W-0 6 FS6 R/W-0 5 FS5 R/W-0 4 FS4 R/W-0 3 FS3 R/W-0 2 FS2 R/W-0 1 FS1 R/W-0 0 FS0 R-0 LEGEND: R/W = Read/Write; R = Read only; -n = value after reset (1) FS0 is a void bit and will always be 0. It is not possible to write a 1 to FS0. CALIBRATION is the value stored in FS15:FS1. Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 23 INA220 SBOS459E – JUNE 2009 – REVISED JANUARY 2016 www.ti.com 9 Application and Implementation NOTE Information in the following applications sections is not part of the TI component specification, and TI does not warrant its accuracy or completeness. TI’s customers are responsible for determining suitability of components for their purposes. Customers should validate and test their design implementation to confirm system functionality. 9.1 Application Information The INA220 is a digital current-shunt monitor with an I2C- and SMBus-compatible interface. It provides digital current, voltage, and power readings necessary for accurate decision-making in precisely-controlled systems. Programmable registers allow flexible configuration for measurement resolution, and continuous-versus-triggered operation. See Table 2 for detailed register information. See Figure 29 for a block diagram of the INA220. 9.2 Typical Application Figure 29 shows a typical application circuit for the INA220. Use a 0.1-μF ceramic capacitor for power-supply bypassing, placed as closely as possible to the supply and ground pins. The input filter circuit consisting of RF1, RF2, and CF is not necessary in most applications. If the need for filtering is unknown, reserve board space for the components and install 0-Ω resistors unless a filter is needed. See Filtering and Input Considerations. Supply (0 to 26V) +3.3V to +5V CBYPASS 0.1µF HighSide Shunt Bus Voltage Input VS (Supply Voltage) INA220 × Load SDA Power Register 2 LowSide Shunt R2F V VIN+ Current Register I C-/SMBUSCompatible Interface ADC R1F CF SCL DATA CLK A0 A1 Voltage Register VIN- I GND Figure 29. General Load, Low- or High-Side Sensing 9.2.1 Design Requirements The INA220 measures the voltage across a current-sensing resistor (RSHUNT) when current passes through the resistor. The device also measures the bus supply voltage, and calculates power when calibrated. This section goes through the steps to program the device for power measurements, and shows the register results in Table 7. The Conditions for the example circuit is: Maximum expected load current = 15 A, Nominal load current = 10 A, VCM = 12 V, RSHUNT = 2 mΩ, VSHUNT FSR = 40 mV (PGA = /1), and BRNG = 0 (VBUS range = 16 V). 9.2.2 Detailed Design Procedure In this example, the 10-A load creates a differential voltage of 20 mV across a 2-mΩ shunt resistor. The voltage present at the IN– pin is equal to the common-mode voltage minus the differential drop across the resistor. The bus voltage for the INA220 is measured at the external VBUS input pin, which in this example is connected to the IN– pin to measure the voltage level delivered to the load. For this example, the voltage at the IN– pin is 11.98 V. For this particular range (40-mV full-scale), this small difference is not a significant deviation from the 12-V common-mode voltage. However, at larger full-scale ranges, this deviation can be much larger. 24 Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 INA220 www.ti.com SBOS459E – JUNE 2009 – REVISED JANUARY 2016 Typical Application (continued) Note that the Bus Voltage register bits are not right-aligned. To compute the value of the Bus Voltage register contents using the LSB of 4 mV, the register must be shifted right by three bits. This shift puts the BD0 bit in the LSB position so that the contents can be multiplied by the 4-mV LSB value to compute the bus voltage measured by the device. The shifted value of the bus voltage register contents is now equal to BB3h, a decimal equivalent of 2995. This value of 2995 multiplied by the 4-mV LSB results in a value of 11.98 V. The Calibration register (05h) is set to provide the device information about the current shunt resistor that was used to create the measured shunt voltage. By knowing the value of the shunt resistor, the device can then calculate the amount of current that created the measured shunt voltage drop. The first step when calculating the calibration value is setting the current LSB. The Calibration register value is based on a calculation that has its precision capability limited by the size of the register and the Current register LSB. The device can measure bidirectional current; thus, the MSB of the Current register is a sign bit that allows for the rest of the 15 bits to be used for the Current register value. For this example, the minimum current LSB would be 457.78 µA/bit assuming a maximum expected current of 15 A using Equation 2. For this example, a value of 1 mA/bit was chosen for the current LSB. Setting the current LSB to this value allows for sufficient precision while serving to simplify the math as well. Using Equation 1 results in a Calibration register value of 20480 or 5000h. The Current register (04h) is internally calculated by multiplying the shunt voltage contents by the Calibration register and then dividing by 4096 using Equation 4. For this example, the shunt voltage of 2000 is multiplied by the Calibration register of 20480 and then divided by 4096 to yield a Current register value of 10000 (2710h). The Power register (03h) is internally calculated by multiplying the Current register value of 10000 by the Bus Voltage register value of 2995 and then dividing by 5000 using Equation 5. For this example, the Power register contents are 5990 (1766h). Multiplying this result by the power LSB that is 20 times the 1 × 10–3 current LSB, or 20 × 10–3, results in a power calculation of 5990 × 20 mW/bit, which equals 119.8 W. This result matches what is expected for this register. A manual calculation for the power being delivered to the load would use 11.98 V (12 VCM – 20 mV shunt drop) multiplied by the load current of 10 A to give a 119.8-W result. +3.3V to +5V RSHUNT 2mΩ +12V VCM 10µF 10A Load 0.1µF VS (Supply Voltage) × V VIN+ VIN- SDA Power Register Current Register Voltage Register I2C-/ SMBUS Compatible Interface SCK A0 A1 I GND Figure 30. Example Circuit Configuration Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 25 INA220 SBOS459E – JUNE 2009 – REVISED JANUARY 2016 www.ti.com Typical Application (continued) 9.2.2.1 Register Results for the Example Circuit Table 7 shows the register readings for the Calibration example. Table 7. Register Results (1) (1) REGISTER NAME ADDRESS CONTENTS ADJ Configuration 00h 019Fh Shunt 01h 07D0h Bus 02h 5D98h Calibration 05h 5000h 20480 Current 04h 2710h 10000 1 mA 10.0 A Power 03h 1766h 5990 20 mW 119.8 W 0BB3 DEC LSB VALUE 2000 10 µV 20 mV 2995 4 mV 11.98 V Conditions: load = 10 A, VCM = 12 V, RSHUNT = 2 mΩ, VSHUNT FSR = 40 mV, and VBUS = 16 V. 9.2.3 Typical Application: –48-V Telecom Current/Voltage/Power Sense With Isolation Figure 31, Figure 32, and Figure 33 show the INA220 in additional circuit configurations for current, voltage, and power monitoring applications. HCPL2300 0.1mF +3.3V to +5V 1/4W Zener or shunt reg 4.3kW 0.1mF 4.3kW 1W 10mF -48V Supply 8 1 7 2 6 3 5 4 SDA 0.1mF 35.7kW +5V HCPL2300 VBUS (Bus Voltage Input) VS (Supply Voltage) INA220 13.7kW 24V Tranzorb 0.1mF 1 8 2 7 3 6 4 5 4.3kW Power Register Data 2 V VIN+ Current Register ADC VIN- I C-/SMBUS Compatible Interface Voltage Register I GND -48V Supply Clock 4.3kW A1 HCPL2300 0.1mF A0 8 1 7 2 6 3 5 4 4.3kW SCL -48V to Load Shunt (40mV max for 12-bit) Figure 31. –48-V Telecom Current/Voltage/Power Sense With Isolation 26 Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 INA220 www.ti.com SBOS459E – JUNE 2009 – REVISED JANUARY 2016 9.2.4 Typical Application: 48-V Telecom Current/Voltage/Power Sense Shunt RSHUNT From Supply Load RG +3.3V to +5V 100Ω MOSFET rated to standoff supply voltage such as BSS84 for up to 50V 10kΩ 5.1V Zener 0.1µF 35.7kΩ OPA333 10µF VBUS (Bus Voltage Input) VS (Supply Voltage) INA220 13.7kΩ 24V Tranzorb × V VIN+ RL 100Ω Power Register Current Register ADC VIN- I2C-/SMBUS Compatible Interface Data (SDA) Clock (SCL) A0 A1 Voltage Register I GND Figure 32. 48-V Telecom Current/Voltage/Power Sense 9.2.5 Typical Application: General Source Low-Side Sensing CBYPASS 0.1µF +3.3V to +5V Bus Voltage Input VS (Supply Voltage) Load INA220 Battery × SDA Power Register DATA SCL Shunt (40mV max for 12-bit) R2F R1F V VIN+ Current Register I2C-/SMBUS Compatible Interface ADC CF CLK A0 A1 Voltage Register VIN- I Address Select GND Figure 33. General Source Low-Side Sensing Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 27 INA220 SBOS459E – JUNE 2009 – REVISED JANUARY 2016 www.ti.com 10 Power Supply Recommendations The input circuitry of the device can accurately measure signals on common-mode voltages beyond its power supply voltage, VS. For example, the voltage applied to the VS power supply terminal can be 5 V, whereas the load power-supply voltage being monitored (the common-mode voltage) can be as high as 26 V. Note also that the device can withstand the full 0-V to 26-V range at the input terminals, regardless of whether the device has power applied or not. Place the required power-supply bypass capacitors as close as possible to the supply and ground terminals of the device to ensure stability. A typical value for this supply bypass capacitor is 0.1 μF. Applications with noisy or high-impedance power supplies may require additional decoupling capacitors to reject power-supply noise. 11 Layout 11.1 Layout Guidelines Connect the input pins (IN+ and IN–) to the sensing resistor using a Kelvin connection or a 4-wire connection. These connection techniques ensure that only the current-sensing resistor impedance is detected between the input pins. Poor routing of the current-sensing resistor commonly results in additional resistance present between the input pins. Given the very low ohmic value of the current-sensing resistor, any additional high-current carrying impedance causes significant measurement errors. Place the power-supply bypass capacitor as close as possible to the supply and ground pins. 11.2 Layout Example A1 IN+ A0 IN± Sense/Shunt Resistor (1) NC VBUS SDA GND SCL VS 2 I C/SMBUS interface Supply bypass capacitor Via to Ground Plane Via to Power Plane (1) Connect the VBUS pin to the power supply rail Figure 34. Layout Recommendation 28 Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 INA220 www.ti.com SBOS459E – JUNE 2009 – REVISED JANUARY 2016 12 Device and Documentation Support 12.1 Related Documentation For related documentation see the TPS2490/1 Positive High-Voltage Power-Limiting Hotswap Controller data sheet (SLVS503). 12.2 Community Resources The following links connect to TI community resources. Linked contents are provided "AS IS" by the respective contributors. They do not constitute TI specifications and do not necessarily reflect TI's views; see TI's Terms of Use. TI E2E™ Online Community TI's Engineer-to-Engineer (E2E) Community. Created to foster collaboration among engineers. At e2e.ti.com, you can ask questions, share knowledge, explore ideas and help solve problems with fellow engineers. Design Support TI's Design Support Quickly find helpful E2E forums along with design support tools and contact information for technical support. 12.3 Trademarks E2E is a trademark of Texas Instruments. All other trademarks are the property of their respective owners. 12.4 Electrostatic Discharge Caution These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam during storage or handling to prevent electrostatic damage to the MOS gates. 12.5 Glossary SLYZ022 — TI Glossary. This glossary lists and explains terms, acronyms, and definitions. 13 Mechanical, Packaging, and Orderable Information The following pages include mechanical, packaging, and orderable information. This information is the most current data available for the designated devices. This data is subject to change without notice and revision of this document. For browser-based versions of this data sheet, refer to the left-hand navigation. Submit Documentation Feedback Copyright © 2009–2016, Texas Instruments Incorporated Product Folder Links: INA220 29 PACKAGE OPTION ADDENDUM www.ti.com 11-Oct-2014 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Pins Package Drawing Qty Eco Plan Lead/Ball Finish MSL Peak Temp (2) (6) (3) Op Temp (°C) Device Marking (4/5) INA220AIDGSR ACTIVE VSSOP DGS 10 2500 Green (RoHS & no Sb/Br) CU NIPDAU | CU NIPDAUAG Level-2-260C-1 YEAR -40 to 125 OOUI INA220AIDGST ACTIVE VSSOP DGS 10 250 Green (RoHS & no Sb/Br) CU NIPDAU | CU NIPDAUAG Level-2-260C-1 YEAR -40 to 125 OOUI INA220BIDGSR ACTIVE VSSOP DGS 10 2500 Green (RoHS & no Sb/Br) CU NIPDAU | CU NIPDAUAG Level-2-260C-1 YEAR -40 to 125 ZAEI INA220BIDGST ACTIVE VSSOP DGS 10 250 Green (RoHS & no Sb/Br) CU NIPDAU | CU NIPDAUAG Level-2-260C-1 YEAR -40 to 125 ZAEI (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes. Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above. Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material) (3) MSL, Peak Temp. - The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature. (4) There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device. (5) Multiple Device Markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation of the previous line and the two combined represent the entire Device Marking for that device. (6) Lead/Ball Finish - Orderable Devices may have multiple material finish options. Finish options are separated by a vertical ruled line. Lead/Ball Finish values may wrap to two lines if the finish value exceeds the maximum column width. Addendum-Page 1 Samples PACKAGE OPTION ADDENDUM www.ti.com 11-Oct-2014 Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis. Addendum-Page 2 PACKAGE MATERIALS INFORMATION www.ti.com 12-May-2015 TAPE AND REEL INFORMATION *All dimensions are nominal Device Package Package Pins Type Drawing SPQ Reel Reel A0 Diameter Width (mm) (mm) W1 (mm) B0 (mm) K0 (mm) P1 (mm) W Pin1 (mm) Quadrant INA220AIDGSR VSSOP DGS 10 2500 330.0 12.4 5.3 3.4 1.4 8.0 12.0 Q1 INA220AIDGSR VSSOP DGS 10 2500 330.0 12.4 5.3 3.3 1.3 8.0 12.0 Q1 INA220AIDGST VSSOP DGS 10 250 180.0 12.4 5.3 3.3 1.3 8.0 12.0 Q1 INA220AIDGST VSSOP DGS 10 250 330.0 12.4 5.3 3.4 1.4 8.0 12.0 Q1 INA220BIDGSR VSSOP DGS 10 2500 330.0 12.4 5.3 3.4 1.4 8.0 12.0 Q1 INA220BIDGSR VSSOP DGS 10 2500 330.0 12.4 5.3 3.3 1.3 8.0 12.0 Q1 INA220BIDGST VSSOP DGS 10 250 330.0 12.4 5.3 3.4 1.4 8.0 12.0 Q1 INA220BIDGST VSSOP DGS 10 250 180.0 12.4 5.3 3.3 1.3 8.0 12.0 Q1 Pack Materials-Page 1 PACKAGE MATERIALS INFORMATION www.ti.com 12-May-2015 *All dimensions are nominal Device Package Type Package Drawing Pins SPQ Length (mm) Width (mm) Height (mm) INA220AIDGSR VSSOP DGS 10 2500 366.0 364.0 50.0 INA220AIDGSR VSSOP DGS 10 2500 370.0 355.0 55.0 INA220AIDGST VSSOP DGS 10 250 195.0 200.0 45.0 INA220AIDGST VSSOP DGS 10 250 366.0 364.0 50.0 INA220BIDGSR VSSOP DGS 10 2500 366.0 364.0 50.0 INA220BIDGSR VSSOP DGS 10 2500 370.0 355.0 55.0 INA220BIDGST VSSOP DGS 10 250 366.0 364.0 50.0 INA220BIDGST VSSOP DGS 10 250 195.0 200.0 45.0 Pack Materials-Page 2 IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily performed. TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use of any TI components in safety-critical applications. In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and requirements. Nonetheless, such components are subject to these terms. No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties have executed a special agreement specifically governing such use. Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of non-designated products, TI will not be responsible for any failure to meet ISO/TS16949. Products Applications Audio www.ti.com/audio Automotive and Transportation www.ti.com/automotive Amplifiers amplifier.ti.com Communications and Telecom www.ti.com/communications Data Converters dataconverter.ti.com Computers and Peripherals www.ti.com/computers DLP® Products www.dlp.com Consumer Electronics www.ti.com/consumer-apps DSP dsp.ti.com Energy and Lighting www.ti.com/energy Clocks and Timers www.ti.com/clocks Industrial www.ti.com/industrial Interface interface.ti.com Medical www.ti.com/medical Logic logic.ti.com Security www.ti.com/security Power Mgmt power.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense Microcontrollers microcontroller.ti.com Video and Imaging www.ti.com/video RFID www.ti-rfid.com OMAP Applications Processors www.ti.com/omap TI E2E Community e2e.ti.com Wireless Connectivity www.ti.com/wirelessconnectivity Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2016, Texas Instruments Incorporated