PAIRUI DBE1-1214 Dc-dc converter Datasheet

DC-DC Converter
SIP-Package
DBE-1 SERIES, 1WATT, 1KVDC, UNREGULATED
FEATURES:
3 years warranty
1000Vdc isolation voltage
Operating temperature range -40°C to +85°C
Compact size
Model
Input voltage
(Vdc)
Output voltage
(Vdc)
Output current
(mA)
Min.
Max.
Efficiency
Typ.
DBE1-0310
3.3
30
300
80%
DBE1-0311
5
20
200
80%
9
11
110
80%
12
8.3
83
80%
DBE1-0314
15
6.8
68
80%
DBE1-0315
24
4.2
42
80%
DBE1-0510
3.3
30
300
80%
DBE1-0511
5
20
200
80%
9
11
110
80%
12
8.3
83
80%
DBE1-0514
15
6.8
68
80%
DBE1-0515
24
4.2
42
80%
DBE1-1210
3.3
30
300
80%
DBE1-1211
5
20
200
80%
9
11
110
80%
12
8.3
83
80%
DBE1-1214
15
6.8
68
80%
DBE1-1215
24
4.2
42
80%
DBE1-2410
3.3
30
300
80%
DBE1-2411
5
20
200
80%
9
11
110
80%
12
8.3
83
80%
DBE1-2414
15
6.8
68
80%
DBE1-2415
24
4.2
42
80%
DBE1-0312
DBE1-0313
DBE1-0512
DBE1-0513
DBE1-1212
DBE1-1213
DBE1-2412
DBE1-2413
3.3(2.97~3.63)
5(4.5~5.5)
12(10.8~13.2)
24(21.6~26.4)
Notes: other input and output models may available on request.
www.pairuigroup.com
Page: 1/3
Date: 05/06/2014
DC-DC Converter
SIP-Package
DBE-1 SERIES, 1WATT, 1KVDC, UNREGULATED
ELECTRICAL
Line regulation
---
± 1.2%
Load regulation
10% ~ 100% full load
Ripple and noise
---
100mVp-p max.
Isolation voltage
---
1000Vdc
Operating temperature range
---
-40°C to +85°C
MTBF
---
3.5x106Hrs
15% max.
Notes: All the data in this article are under test with “TA+25°C, humidity<75%, rated input and rated load”
mode.
MECHANICAL
CONNECTION
6.0
(0.236 )
11.5
(0.453)
10.0
(0.394)
4.1
(0.161)
1.94
(0.076)
0.9
(0.035)
PIN #
SINGLE
1
GND
2
+Vin
3
-Vo
4
+Vo
Note:
* Unit is mm(inch).
TEMPERATURE PROFILE
www.pairuigroup.com
Page: 2/3
Date: 05/06/2014
DC-DC Converter
SIP-Package
DBE-1 SERIES, 1WATT, 1KVDC, UNREGULATED
CAPACITIVE LOADS SELECTION
Single Output
Cin
(Vdc)
(μF)
3.3/5
4.7
5
10
±5
4.7
12
2.2
9
4.7
±9
2.2
24
1
12
2.2
±12
1
-
-
15/24
1
±15
0.47
Voltage
Cout
Dual Output
Vin
(μF)
(Vdc)
Cout
Voltage
(μF)
(Vdc)
NOTES
RECOMMENDED TEST AND APPLICATION CIRCUIT
In order to ensure the efficiency and dependability of the module, the minimum specified load must be less than 10% of
rated load. If the output power is low, we recommend to add an external 10% loading resistor in parallel.
FUSE: depends on the actual input current;
TVS: depends on the actual input voltage;
Recommended capacitor:C1, C2, C5,about 0.1uF; for C6,C7,please check the capacitive load; C3,C4:2KV/1nF.
www.pairuigroup.com
Page: 3/3
Date: 05/06/2014
Similar pages