FTR-K1 SERIES POWER RELAY 1 POLE - 16A 80A Inrush type RoHS compliant FTR-K1 Series n FEATURES l l l l l l l l l Peak 80A inrush current (1 form A type) Low profile (height: 15.7mm) HIGH ISOLATION Insulation Distance (between coil and contacts): 10mm min. Dielectric strength: 5KV Surge strength: 10KV Class F coil wire Low coil power (400mW) Cadmium free contacts SAFETY STANDARDS UL, CSA, VDE, SEMKO approved UL, CSA TV-5 rating approved (1 form A type) RoHS Compliant VDE Glow-wire ignitablility test 775 (IEC60335-1) approved n ORDERING INFORMATION [Example] FTR-K1 (a) C (b) K (c) 005 (d) W – BG (e) (f ) (a) Series Name FTR-K1 : FTR-K1 Series (b) Contact Arrangement A C : 1 form A (SPST-NO) : 1 form C (SPDT) (standard type "K" only) (c) Coil Type / Enclosure K : Standard (400 mW) / Flux free (16 A, 12A contacts only) (d) Nominal Voltage 005 018 024 : 5 VDC, 006 : 6VDC, : 18 VDC (standard type only) : 24VDC, 028 : 28VDC (e) Contact Material / TV type W T : AgSnO2 (1 form C) : AgSnO2 / TV-5 rated (1form A TV-5) (f) Special Designation BG : Gold plated 3µm 009 : 9VDC 012 : 12VDC 022 : 22VDC (standard type only), 048 : 48VDC Actual marking does not carry the type name : "FTR" E.g.: Ordering code: FTR-K1CK012W Actual marking: K1CK012W FTR-K1 SERIES n PART NUMBERS 400mW type Ordering Part Number Series Contact Coil Power Coil Voltage FTR-K1AK005T 5 FTR-K1AK006T 6 FTR-K1AK009T 9 FTR-K1AK012T 12 A: 1 form A FTR-K1AK018T K: 400 mW 18 FTR-K1AK022T 22 FTR-K1AK024T 24 FTR-K1AK028T 28 FTR-K1AK048T FTR-K1CK005W K: 430 mW FTR-K1 T: AgSnO2 48 5 FTR-K1CK006W 6 FTR-K1CK009W 9 FTR-K1CK012W C: 1 form C FTR-K1CK018W Contact Material K: 400 mW 12 18 FTR-K1CK022W 22 FTR-K1CK024W 24 FTR-K1CK028W 28 FTR-K1CK048W K: 430 mW W: AgSnO2 48 n COIL DATA CHART Coil Voltage Nominal Voltage (VDC) Max. Coil Voltage*1 Coil Resistance (±10%) Must Operate Voltage*2 Must Release Voltage*2 005 5 12.2 VDC 62 Ω 3.5 VDC 0.5 VDC 006 6 14.7 VDC 90 Ω 4.2 VDC 0.6 VDC 009 9 22.0 VDC 202 Ω 6.3 VDC 0.9 VDC 012 12 29.4 VDC 360 Ω 8.4 VDC 1.2 VDC 018 18 44.1 VDC 810 Ω 12.6 VDC 1.8 VDC 022 22 53.9 VDC 1,210 Ω 15.4 VDC 2.2 VDC 024 24 58.8 VDC 1,440 Ω 16.8 VDC 2.4 VDC 028 28 68.6 VDC 1,960 Ω 19.6 VDC 2.8 VDC 048 48 117.6 VDC 5,360 Ω 33.6 VDC 4.8 VDC Nominal Power (mW) 400 430 Note: All values in the table are measured at 20°C. *1: No contact current at 20°C *2: Specified values are subject to pulse wave voltage FTR-K1 SERIES n SPECIFICATIONS Item FTR-K1 AK ( ) T Standard FTR-K1 CK ( )W Standard Contact Arrangement 1 form A 1 from C Material AgSnO2 Resistance (initial) Maximum 100 mΩ at 1 A, 6 VDC Rating 16 A, 250 VAC / 24 VDC Maximum Carrying Current*1 16 A Maximum Inrush Current 80A (20ms) 250VAC Maximum Switching Rating 4,000 VA / 384W Maximum Switching Voltage 440 VAC / 300VDC Minimum Switching Load*2 10 mA 5 VDC Nominal Power (at 20ºC) 400mW (at 430mW 48V coil) Operate Power (at 20ºC) 200 mW (210mW at 48V coil) Operating Temperature -40ºC to +85ºC (no frost) Time Value Operate Maximum 15ms (at nominal voltage, no bounce) Release (without diode) Maximum 5ms (at nominal voltage, no bounce) Life Mechanical 20 x 106 operations minimum Coil AC Contact rating 100 x 103 operations min. 50 x 103 operations min. DC contact rating 100 x 103 operations min. 30 x 103 operations min. Peak Inrush (80A) 10 x 103 operations min. Lamp load (UL TV-5) 25 x 103 operations min. Vibration Resistance Misoperation 10 to 55 Hz, at double amplitude of 0.7 mm Endurance 10-55Hz, at double amplitude of 1.5 mm Shock Resistance Misoperation Electrical Other Weight Endurance - Min. 100m/s2 (11±1ms) Min. 1,000m/s2 (6±1ms) Approximately 13g *1 Need to consider the heat from PCB when max. current is more than 10A. *2 Minimum switching loads mentioned above are reference values. Please perform the confirmation test with the actual load before production since reference values may vary according to switching frequencies, environmental conditions and expected reliability levels. FTR-K1 SERIES n INSULATION Item FTR-K1 Note Resistance (initial) Minimum 1,000 MΩ 1 min. at 500 VDC Dielectric Strength open contacts 1,000 VAC (50/60 Hz) 1 min. coil and contacts 5,000 VAC (50/60 Hz) 1 min. Surge Voltage (coil and contact) 10,000 V Clearance/Creepage 10 mm / 10 mm Insulation (DIN EN61810-1 VDE0435) Voltage Pollution Isolation material group 250 V 3 IIIa 1.2 x 50µs standard wave Isolation category / Reference voltage (VDE0110b) C / 250 V n SAFETY STANDARDS Type Compliance Contact rating FTR-K1CK ( ) W UL UL 508 E63614 FTR-K1AK ( ) T Flammability: UL 94-V0 (plastics) 16A, 277 VAC (resistive) 20A, 277 VAC (resistive) 1 HP, 277VAC 1/2 HP, 125VAC 1/8 HP, 125VAC Pilot duty: B300 16A, 24 VAC (resistive) 16A, 277 VAC (resistive) 20A, 277 VAC (resistive) 1 HP, 277VAC 1/2 HP, 125VAC TV-5, 120VAC 25,000 cycles Pilot duty: A300 CSA C22.2 No. 14 LR 40304 VDE 0435, 0631, 0700, 0860, 40013848 16A, 250 VAC (cosØ=1), 85˚C 3.5A, 250 VAC (cosØ=0.4), 85˚C 16 A 24VDC (0ms), 85˚C 5A, 250 VAC 10,000 times, 85˚C SEMKO EN 61058-1:1992 and A1 EN 61095:1993 and A1+A11 250VAC, 16 (3)A 40T85 5A/80A 250VAC 40T85 Complies with NEMKO, DEMKO, FIMKO FTR-K1 SERIES n CHARACTERISTIC DATA 6A 70 60 0A 50 40 30 0A 20 0 0 0 0.2 0.4 0.6 0.8 1.2 FTR-K 2 0A 6A 1.5 mu 0.5 0 250VAC resistive 24VDC resistive FTR-KAK 250VAC cosφ=0.7 300 200 00 50 DC24V τ=7ms 30 20 AC250V cosφ=0.4 DC24V τ=15ms 0 2 4 6 8 0 2 4 6 8 20 Contact Current Load (A) Service Life (03 operations) Service Life (03 operations) 20 coil) l coil) ltage (coo erate vo must op 40 60 80 00 200 50 30 20 4 6 0 20 50 00 200 500 000 FTR-KCK02W n=200 Operate Release 70 60 50 40 30 20 24VDC τ=15ms 2 DC resistive 0.2 80 250VAC cosφ=0.4 24VDC τ=7ms 0 0.5 90 00 0 2 00 250VAV cosφ=0.7 24VDC resistive 300 5 Distribution of Operation & Release Voltage 250VAC resistiveFTR-KCK 500 0 Contact Voltage (V) Life Curve 000 FTR-K AC resistive 20 0.1 Ambient temperature (ºC) Life Curve 500 0 ge (hot te volta st opera Coil Power (W) 000 Maximum Switching Power 50 Switching Current (A) 80 Operating Range 2.5 Distribution (%) Temperature Rise (deg.) 90 Nominal voltage multiplying factor Coil Temperature Rise 00 8 0 0 2 4 6 8 20 Contact Current Load (A) 0 0 0 20 30 40 50 60 70 80 Nominal Voltage Multiplying Factor 90 Distribution (%) 80 Release 70 FTR-KCK02W n=200 Make 90 Operate 80 60 50 40 30 20 Break 70 60 50 40 30 20 0 0 Distribution of Contact Resistance 00 FTR-KCK02W n=200 Distribution (%) 00 Distribution of Operation & Release Time 0 0 1 2 3 4 5 6 Time (ms) 7 8 9 0 0 0 0 20 30 40 Contact Resistance (mΩ) 50 FTR-K1 SERIES n DIMENSIONS l Dimensions l Schematics (BOTTOM VIEW) FTR-K1AK ( ) T 5 12.7 +0.3 15.7 +0.3 29 +0.3 6 4 7 8 COM NO COM NO 2 3 φ 0.45 (2.6) 0.3 20 0.5 3.3 Orientation mark 5 2.6 l PC board mounting hole layout (BOTTOM VIEW) 0.9 0.9 7.5 (2.6) 5 20 2-Ø ±0.1 7.5 (2.6) 4-Ø1.3 l Dimensions l Schematics (BOTTOM VIEW) FTR-K1CK ( ) W 5 15.7 +0.3 7 6 12.7 +0.3 29 +0.3 8 NC COM NO NC COM NO 4 2 3 0.3 5 (2.6) 20 5 0.9 0.9 2.6 7.5 l PC board mounting hole layout (BOTTOM VIEW) (2.6) 20 2-φ1 ±0.1 6-φ1.3 -0 5 5 (2.6) 0.5 0.5 7.5 φ 0.45 3.3 Orientation mark Unit: mm FTR-K1 SERIES RoHS Compliance and Lead Free Relay Information 1. General Information Relays produced after the specific date code that is indicated on each data sheet are lead-free now. All of our signal and power relays are lead-free. Please refer to Lead-Free Status Info. (http://www.fujitsu.com/us/downloads/MICRO/fcai/relays/lead-free-letter.pdf) l Lead free solder paste currently used in relays is Sn-3.0Ag-0.5Cu. l All signal and power relays also comply with RoHS. Please refer to individual data sheets. Relays that are RoHS compliant do not contain the 5 hazardous materials that are restricted by RoHS directive (lead, mercury, chromium IV, PBB, PBDE and DecaBDE). l It has been verified that using lead-free relays in leaded assembly process will not cause any problems (compatible). l “LF” is marked on each outer and inner carton. (No marking on individual relays). Note: Cadmium was exempted from RoHS on October 21, 2005. (Amendment to Directive 2002/95/EC) l 2. Recommended Lead Free Solder Profile l Recommended solder paste Sn-3.0Ag-0.5Cu. Solder condition Flow Solder condition: Pre-heating: Soldering: maximum 120˚C dip within 5 sec. at 260˚C solder bath Solder by Soldering Iron: Soldering Iron Temperature: maximum 360˚C Duration: maximum 3 sec. We highly recommend that you confirm your actual solder conditions 3. Moisture Sensitivity l Moisture Sensitivity Level standard is not applicable to electromechanical realys. 4. Tin Whisker l Dipped SnAgCu solder is known as low risk tin whisker. No considerable length whisker was found by our in house test. FTR-K1 SERIES Fujitsu Components International Headquarter Offices Japan Fujitsu Component Limited Gotanda-Chuo Building 3-5, Higashigotanda 2-chome, Shinagawa-ku Tokyo 141, Japan Tel: (81-3) 5449-7010 Fax: (81-3) 5449-2626 Email: [email protected] Web: www.fcl.fujitsu.com Europe Fujitsu Components Europe B.V. Diamantlaan 25 2132 WV Hoofddorp Netherlands Tel: (31-23) 5560910 Fax: (31-23) 5560950 Email: [email protected] Web: emea.fujitsu.com/components/ North and South America Fujitsu Components America, Inc. 250 E. Caribbean Drive Sunnyvale, CA 94089 U.S.A. Tel: (1-408) 745-4900 Fax: (1-408) 745-4970 Email: [email protected] Web: http://www.fujitsu.com/us/services/edevices/components/ Asia Pacific Fujitsu Components Asia Ltd. 102E Pasir Panjang Road #01-01 Citilink Warehouse Complex Singapore 118529 Tel: (65) 6375-8560 Fax: (65) 6273-3021 Email: [email protected] Web: http://www.fujitsu.com/sg/services/micro/components/ ©2008 Fujitsu Components America, Inc. All rights reserved. All trademarks or registered trademarks are the property of their respective owners. Fujitsu Components America or its affiliates do not warrant that the content of datasheet is error free. In a continuing effort to improve our products Fujitsu Components America, Inc. or its affiliates reserve the right to change specifications/datasheets without prior notice. Rev. July 23, 2008.