1C. M3500-0204 VCO TECHNICAL SPECIFICATIONS
ABSOLUTE MAXIMUM / MINIMUM RATINGS
PARAMETER
RATING
Maximum Supply Voltage
Tuning Voltage Min/Max
+14.5V
0/20V
GUARANTEED PERFORMANCE (0-70° C)
PARAMETER
DATA
Power Dissipation
Frequency Tuning Range
Power Output (50Ω)
420 mW max
(35 mA @ +12V)
200 to 400 MHz min
10 dBm min
TYPICAL PERFORMANCE (0-70° C)
PARAMETER
Nominal Supply Voltage
Power Output (50Ω)
Typical Current
Tuning Voltage
FM(Phase)Noise:
DATA
1 kHz Offset
10 kHz Offset
100 kHz Offset
1 MHz Offset
Frequency Pushing
Frequency Pulling (12dB Return Loss)
Harmonic Spurious (Average)
Tuning Port Bandwidth: @ Tuning Voltage = 1.8 V
@ Tuning Voltage = 6.8V
@ Tuning Voltage = 13.0V
+12V
+12 .5 dBm
26mA
1.6-15.4V
-80 dBc/Hz
<-101 dBc/Hz
<-118 dBc/Hz
<-130 dBc/Hz
0.3 MHz/V for 12 ± 1V
5 MHz peak-peak
-4.5 dBc
640 kHz
1.2 MHz
1.4 MHz
2C. P ERFORMANCE CURVES FOR M3500-0204
200-400 MHZ TYPICAL OUTPUT FREQUENCY / MODULATION SENSITIVITY VERSUS TUNING VOLTAGE
FREQUENCY
KV ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪
200-400 MHZ VCO TYPICAL OUTPUT POWER VERSUS TUNING VOLTAGE
MICRONETICS / 26 HAMPSHIRE DRIVE / HUDSON, NH 03051 / TEL: 603-883-2900 / FAX: 603-882-8987 / CUSTOMER HOTLINE: 1-800-963-3382 / WEB: WWW.MWIRELESS.COM