MPD MPV1560RI4 Ultra wide input, compact industrial grade, pv power dc/dc con vert er Datasheet

MPV1560RI4
Ultra Wide Input, Compact
Industrial Grade, PV Power
DC/DC Converters
Electrical Specifications
Key Features:
• 15W Output Power
• 10:1 Input Range
• 4,000 VAC Isolation
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Conditions
200 VDC Input
600 VDC Input
1,000 VDC Input
200 VDC Input
600 VDC Input
1,000 VDC Input
VIN = 200 - 1,000 VDC
Input Current
• Meets EN 62109
• Wide -40°C to +70°C Oper.
• Reverse Input Volt Prot.
Inrush Current
• Output Over Volt Protection Start-Up Time
Output
• Compact Case
• >300 kHours MTBF
• Chassis/DIN Rail Options
Min.
100
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Temperature Coefficient
Over Current Protection
Output Short Circuit
Conditions
Typ.
600
Max.
1,000
120.0
40.0
22.0
7.0
20.0
30.0
Min.
VIN = MIN to MAX
IOUT = 0% to 100%
See Note 1
Typ.
±1.0
±0.5
±0.5
100
±0.02
Units
VDC
mA
A
1.0
S
Max.
±2.0
±1.0
±1.0
200
Units
%
%
%
mV P - P
%/°C
% IOUT
Max.
Units
VAC
kHz
Hiccup Circuit, Autorecovery
110
Continuous (Autorecovery)
General
Parameter
Isolation Voltage
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions, See Note 2
Conducted Emissions, See Note 2
Conditions
60 Seconds
Min.
4,000
Typ.
75
Standard
Criteria
Level
Class A
Class A
±6 kV Contact
±8 kV Air
10V/m
±4 kV
±2 kV L-L
10 Vrms
EN 55022
EN 55022
ESD
EN 61000-4-2
B
RS
EFT, See Note 3
Surge, See Note 4
CS
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
A
B
B
A
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size, Module, Chassis /DIN Rail Mount
Case Material
Weight, Module, Chassis /DIN Rail Mount
Conditions
Min.
Typ.
-40
+25
-40
Free Air Convection
RH, Non-condensing
Ambient
Max.
+70
+105
Units
°C
°C
95
%
See Mechanical Drawings (Starting Page 4)
Black, Flame Retardant, Non-Conductive Plastic (UL94-V0)
See Mechanical Drawings (Starting Page 4)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
300
Typ.
Max.
Units
kHours
Conditions
Wave Soldering
Manual Soldering
Min.
255
350
Typ.
260
360
Max.
265
370
Units
Absolute Maximum Ratings
Parameter
Lead Temperature, See Note 5
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Output
Efficiency
Voltage (VDC)
Over
Fuse
Voltage Capacitive
Rating
Load
Protection (µF, Max)
Slow-Blow
Voltage
Current
Current
Nominal
Range
(VDC)
(mA, Max)
(mA, Min)
MPV1560S-12RI4
600
100 - 1,000
12.0
1,250
0.0
77
15.0
2,000
2.0
MPV1560S-15RI4
600
100 - 1,000
15.0
1,000
0.0
78
19.0
1,200
2.0
MPV1560S-24RI4
600
100 - 1,000
24.0
625
0.0
80
28.0
470
2.0
Notes:
1. To meet the specified ripple and noise levels, external capacitors are required. See the “Simple
Connection” diagram below. Recommended values for all external components are given in
the table at the bottom of the page. For more information, please contact the factory.
2. All units will meet EN 55022 (CE/RE) class A with the input circuit shown in the “Typical Connection”
diagram below. Contact the factory for more information.
3. All units will meet EN 61000-4-4 (±4 kV) with the input circuit shown in the “Typical Connection”
diagram below. Contact the factory for more information.
(%, Typ)
(VDC Typ)
(A)
4. All units will meet the requirements of EN 61000-4-5 (±1 kV/±2 kV), with the input circuit shown
in the “Typical Connection” diagram below. Contact the factory for more information.
5. Lead temperature is measured 1.5 mm from the case.
6. Operation at no load will not damage the units, however, they may not meet all specifications.
7. It is recommended that a fuse be used on the input of a power supply for protection. For
the MPV1560RI4 series, a 2.0A slow blow, with a voltage rating over 1 kV, should be
used.
Simple Connection
The diagram at left illustrates a typical connection of the
MPV1560S-xxRI4 series. Output capacitors C6 and
C5 are filtering components. They are required to meet
ripple and noise specifications. Capacitor C5 is ceramic
and capacitor C6 is a high frequency, low ESR electrolytic.
The recommended input components are a fuse, NTC,
and MOV. The recommended component values for
these are given in the table below.
Typical Connection: With External EMC Components
For applications that require meeting higher EMC standards, the circuit shown above is recommended. Some notes
on this diagram (starting with the input circuit) are:
1. It is recommended that an external fuse be used. The recommended fuse is 2A/1,000V.
2. The NTC helps to prevent damage to the module in the event an input current surge occurs. The recommended
value is given in the table below.
3. The MOV helps to prevent damage to the module in case an input voltage surge occurs. The recommended value
is given in the table below.
4. Capacitors C1, C2, C3 and C4 are input filter components (connected in series to achieve the required capacitance
level). Resistors R1, R2, R3 and R4 help to balance the current across the capacitors.
5. Recommended values for components are:
Model
Number
6. Capacitor C5 is ceramic. This capacitor is used to filter high frequency noise. A recommended value is
given in the table below.
7. Capacitor C6 is an electrolytic. A low ESR, high frequency capacitor should be used. The recommended
value is given in the table below.
8. The output TVS will help protect system circuitry if power supply fails. A recommended value is given in
the table below.
9. Derating on all capacitors should be 80% or more.
10. To meet safety regulations, the board trace widths should be >3 mm, the distance between traces should
be >6 mm, and the distance between traces and ground should be >6 mm. Contact the factory for more
information.
External Components
Fuse
MOV
NTC
LDM
LCM
C1, C2, C3, C4
R1, R2, R3, R4
C5
2A/1 kV
SK14880
10D-11
4.7 mH/0.38A
10 mH/0.5A
47 µF/400V
1 M⍀/2W
1 µF/50V
MPV1560S-12RI4
MPV1560S-15RI4
120 µF/25V
68 µF/35V
MPV1560S-24RI4
Page 2
C6
We Power Your Success - For Less
TVS
SMBJ15A
SMBJ20A
SMBJ33A
www.micropowerdirect.com
Temperature Derating Curve: VIN = 100 to 150V
Temperature Derating Curve: VIN = 150 to 1,000V
Input Voltage Derating Curve: Ambient Temp = 25°C
The MPV1560S-xxRI4 series is designed to
be operated in an environment that has natural air
cooling. It should not be used in a closed or sealed
environment. For more information, contact the factory.
Efficiency vs Input Voltage (Full Load)
MPD
•
292 Page Street Ste D Stoughton, MA 02072
Efficiency vs Output Power (VIN= 500 VDC)
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
Mechanical Dimensions
Pin Connections
Pin
1
2
3
4
5
Function
No Connection
-VIN
+VIN
+VOUT
-VOUT
Notes:
•
•
•
•
All models of the MPV1560S-xxRI4 series are available
assembled on adapter plates for mounting to a chassis
or on a DIN rail. Similar to the product pictured at right.
the product assembled on an adapter, add the designation for
the adapter to the end of the product number. For example:
MPV1560S-12RI4-A2C.
Mechanical dimensions for these adapters are shown in
the diagrams below and on the following page. To order
Please contact the factory for more information.
All dimensions are typical in inches (mm)
General Dimension Tolerance x.xx = ±0.02 (±0.50)
Pin Diameter Tolerance x.xxx = ±0.004 (±0.100)
Weight: 0.3.35 Oz (95g)
Mechanical Dimensions, A2C : With Chassis Mount & Power Good LED
Pin Connections
Pin
Function
1
-VIN
2 No Connection
3
+VIN
4
+VOUT
Pin
Function
5 No Connection
6 No Connection
7
-VOUT
Notes:
•
•
•
•
•
•
Page 4
We Power Your Success - For Less
All dimensions are typical in inches (mm)
General Dimension Tolerance x.xx = ±0.02 (±0.50)
Wire Range: 12 to 24 AWG
Tightening Torque: 0.4 Nm Max
Weight: 0.5.26 Oz (150g)
The LED indicates the output voltage is present (LED “On”)
www.micropowerdirect.com
Mechanical Dimensions, A4C: With DIN Rail Mount Option & Power Good LED
Pin Connections
Pin
Function
1
-VIN
2 No Connection
3
+VIN
4
+VOUT
Pin
Function
5 No Connection
6 No Connection
7
-VOUT
Notes:
•
•
•
•
•
•
•
All dimensions are typical in inches (mm)
General Dimension Tolerance x.xx = ±0.02 (±0.50)
Wire Range: 12 to 24 AWG
Tightening Torque: 0.4 Nm Max
Weight: 6.66 Oz (190g)
For use with a TS35 type DIN rail
The LED indicates the output voltage is present (LED “On”)
PV DC/DC’s
MPD offers a wide variety of DC/DC
converters specifically designed for
photovoltaic power systems. Typical
features include:
• Ultra wide 10:1 & 12:1 input ranges
• 4 kVAC Isolation
• 5W to 40W Output Power
• EN 62109 Compliance
• Rugged, Compact Packaging
• -40°C to + 70°C Operation
• High Reliability
• Chassis Mounting Available
• DIN Rail Mounting Available
Call today for complete information
or product samples.
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages