M58WR016KU M58WR016KL M58WR032KU M58WR032KL M58WR064KU M58WR064KL 16-, 32- and 64-Mbit (x 16, Mux I/O, Multiple Bank, Burst) 1.8 V supply Flash memories Features ■ Supply voltage – VDD = 1.7 V to 2 V for Program, Erase and Read – VDDQ = 1.7 V to 2 V for I/O buffers – VPP = 9 V for fast Program ■ Multiplexed address/data ■ Synchronous / Asynchronous Read – Synchronous Burst Read mode: 86 MHz – Random Access: 60 ns, 70 ns ■ Synchronous Burst Read Suspend ■ Programming time – 10 µs by Word typical for Factory Program – Double/Quadruple Word Program option – Enhanced Factory Program options ■ Memory blocks – Multiple Bank memory array: 4 Mbit Banks – Parameter Blocks (top or bottom location) ■ Dual operations – Program Erase in one Bank while Read in others – No delay between Read and Write operations ■ Block locking – All blocks locked at Power up – Any combination of blocks can be locked – WP for Block Lock-Down ■ Security – 128 bit user programmable OTP cells – 64 bit unique device number ■ Common Flash Interface (CFI) ■ 100,000 program/erase cycles per block December 2007 FBGA VFBGA44 (ZA) 7.5 × 5 mm ■ Electronic signature – Manufacturer Code: 20h – Top Device Code, M58WR016KU: 8823h M58WR032KU: 8828h M58WR064KU: 88C0h – Bottom Device Code, M58WR016KL: 8824h M58WR032KL: 8829h M58WR064KL: 88C1h ■ ECOPACK® packages available Rev 2 1/123 www.numonyx.com 1 Contents M58WRxxxKU, M58WRxxxKL Contents 1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2 Signal descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3 2.1 Address inputs (ADQ0-ADQ15, A16-Amax) . . . . . . . . . . . . . . . . . . . . . . . 17 2.2 Data input/output (ADQ0-ADQ15) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 2.3 Chip Enable (E) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 2.4 Output Enable (G) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 2.5 Write Enable (W) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 2.6 Write Protect (WP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 2.7 Reset/Power-Down (RP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 2.8 Latch Enable (L) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 2.9 Clock (K) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 2.10 Wait (WAIT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 2.11 Bus Invert (BINV) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 2.12 VDD supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 2.13 VDDQ supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 2.14 VPP Program supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 2.15 VSS ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 2.16 VSSQ ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Bus operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 3.1 Bus Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 3.2 Bus Write . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 3.3 Address Latch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 3.4 Output Disable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 3.5 Standby . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 3.6 Reset/Power-Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 4 Command interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 5 Command interface - Standard commands . . . . . . . . . . . . . . . . . . . . . 23 5.1 2/123 Read Array command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 M58WRxxxKU, M58WRxxxKL 6 5.2 Read Status Register command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 5.3 Read Electronic Signature command . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 5.4 Read CFI Query command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 5.5 Clear Status Register command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 5.6 Block Erase command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 5.7 Program command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 5.8 Program/Erase Suspend command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 5.9 Program/Erase Resume command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 5.10 Protection Register Program command . . . . . . . . . . . . . . . . . . . . . . . . . . 27 5.11 Set Configuration Register command . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 5.12 Block Lock command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 5.13 Block Unlock command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 5.14 Block Lock-Down command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Command interface - Factory program commands . . . . . . . . . . . . . . . 31 6.1 Double Word Program command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 6.2 Quadruple Word Program command . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 6.3 Enhanced Factory Program command . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 6.4 7 Contents 6.3.1 Setup Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 6.3.2 Program Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 6.3.3 Verify Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 6.3.4 Exit Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Quadruple Enhanced Factory Program command . . . . . . . . . . . . . . . . . . 35 6.4.1 Setup Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 6.4.2 Load Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 6.4.3 Program and Verify Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 6.4.4 Exit Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 7.1 Program/Erase Controller Status bit (SR7) . . . . . . . . . . . . . . . . . . . . . . . 38 7.2 Erase Suspend Status bit (SR6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 7.3 Erase Status bit (SR5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 7.4 Program Status bit (SR4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 7.5 VPP Status bit (SR3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 7.6 Program Suspend Status bit (SR2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 3/123 Contents 8 9 M58WRxxxKU, M58WRxxxKL 7.7 Block Protection Status bit (SR1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 7.8 Bank Write/Multiple Word Program Status bit (SR0) . . . . . . . . . . . . . . . . 40 Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 8.1 Read Select bit (CR15) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 8.2 Bus Invert Configuration (CR14) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 8.3 X-Latency bits (CR13-CR11) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 8.4 Wait Polarity bit (CR10) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 8.5 Data Output Configuration bit (CR9) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 8.6 Wait Configuration bit (CR8) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 8.7 Burst Type bit (CR7) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 8.8 Valid Clock Edge bit (CR6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 8.9 Power-Down bit (CR5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 8.10 Wrap Burst bit (CR3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 8.11 Burst length bits (CR2-CR0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Read modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 9.1 Asynchronous Read mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 9.2 Synchronous Burst Read mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 9.2.1 9.3 Synchronous Burst Read Suspend . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Single Synchronous Read mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 10 Dual operations and multiple bank architecture . . . . . . . . . . . . . . . . . 54 11 Block locking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 11.1 Reading a block’s lock status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 11.2 Locked state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 11.3 Unlocked state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 11.4 Lock-Down state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 11.5 Locking operations during Erase Suspend . . . . . . . . . . . . . . . . . . . . . . . . 57 12 Program and erase times and endurance cycles . . . . . . . . . . . . . . . . . 59 13 Maximum rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 4/123 M58WRxxxKU, M58WRxxxKL Contents 14 DC and AC parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 15 Package mechanical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 16 Part numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 Appendix A Block address tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 Appendix B Common Flash Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 Appendix C Flowcharts and pseudocodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 16.1 Enhanced Factory Program pseudocode . . . . . . . . . . . . . . . . . . . . . . . . 114 16.2 Quadruple enhanced factory program pseudocode . . . . . . . . . . . . . . . . 116 Appendix D Command interface state tables. . . . . . . . . . . . . . . . . . . . . . . . . . . 117 Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 5/123 List of tables M58WRxxxKU, M58WRxxxKL List of tables Table 1. Table 2. Table 3. Table 4. Table 5. Table 6. Table 7. Table 8. Table 9. Table 10. Table 11. Table 12. Table 13. Table 14. Table 15. Table 16. Table 17. Table 18. Table 19. Table 20. Table 21. Table 22. Table 23. Table 24. Table 25. Table 26. Table 27. Table 28. Table 29. Table 30. Table 31. Table 32. Table 33. Table 34. Table 35. Table 36. Table 37. Table 38. Table 39. Table 40. Table 41. Table 42. Table 43. Table 44. Table 45. Table 46. Table 47. Table 48. 6/123 Signal names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 M58WR016KU/L bank architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 M58WR032KU/L bank architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 M58WR064KU/L bank architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Bus operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Command codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Standard commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Electronic signature codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Factory Program commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Status Register bits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 X-latency settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Burst type definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Dual operations allowed in other banks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Dual operations allowed in same bank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Dual operation limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Lock status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Program, erase times and endurance cycles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Absolute maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Operating and ac measurement conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 Capacitance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 DC characteristics - currents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 DC characteristics - voltages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Asynchronous Read ac characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Synchronous Read ac characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Write ac characteristics, Write Enable controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Write ac characteristics, Chip Enable controlled. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 Reset and Power-up ac characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 VFBGA44 7.5 × 5 mm, 10 × 4 ball array, 0.50 mm pitch, package mechanical data . . . . . 77 Ordering information scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 Top boot block addresses, M58WR016KU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 Bottom boot block addresses, M58WR016KL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 Top boot block addresses, M58WR032KU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 Bottom boot block addresses, M58WR032KL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 Top boot block addresses, M58WR064KU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 Bottom boot block addresses, M58WR064KL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 Query structure overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 CFI query identification string . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 CFI query system interface information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 Device geometry definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 Primary algorithm-specific extended query table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 Protection Register information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 Burst Read Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 Bank and Erase block region information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 Bank and Erase block region 1 information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 Bank and Erase block region 2 information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 Command interface states - modify table, next state . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 Command interface states - Modify table, next output . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 M58WRxxxKU, M58WRxxxKL Table 49. Table 50. Table 51. List of tables Command interface states - Lock table, next state. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 Command interface states - Lock table, next output . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 Document revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 7/123 List of figures M58WRxxxKU, M58WRxxxKL List of figures Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. Figure 6. Figure 7. Figure 8. Figure 9. Figure 10. Figure 11. Figure 12. Figure 13. Figure 14. Figure 15. Figure 16. Figure 17. Figure 18. Figure 19. Figure 20. Figure 21. Figure 22. Figure 23. Figure 24. Figure 25. Figure 26. Figure 27. Figure 28. Figure 29. 8/123 Logic diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 VFBGA44 connections (top view through package) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 M58WR016KU/L memory map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 M58WR032KU/L memory map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 M58WR064KU/L memory map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Protection Register memory map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 X-latency and data output configuration example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Wait configuration example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 AC measurement I/O waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 AC measurement load circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Asynchronous random access read ac waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 Synchronous Burst Read ac waveforms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Single Synchronous Read ac waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Synchronous Burst Read Suspend ac waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Clock input ac waveform. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Write ac waveforms, Write Enable controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 Write ac waveforms, Chip Enable controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Reset and Power-up ac waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 VFBGA44 7.5 × 5 mm, 10 × 4 ball array, 0.50 mm pitch, bottom view package outline . . 76 Program flowchart and pseudocode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 Double Word Program flowchart and pseudocode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 Quadruple Word Program flowchart and pseudocode . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 Program Suspend & Resume flowchart and pseudocode . . . . . . . . . . . . . . . . . . . . . . . . 108 Block Erase flowchart and pseudocode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 Erase Suspend & Resume flowchart and pseudocode . . . . . . . . . . . . . . . . . . . . . . . . . . 110 Locking operations flowchart and pseudocode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 Protection Register Program flowchart and pseudocode . . . . . . . . . . . . . . . . . . . . . . . . . 112 Enhanced Factory Program flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113 Quadruple enhanced factory program flowchart. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 M58WRxxxKU, M58WRxxxKL 1 Description Description The M58WR016KU/L, M58WR032KU/L and M58WR064KU/L are 16-Mbit (1 Mbit × 16), 32Mbit (2 Mbit × 16) and 64-Mbit (4 Mbit × 16) non-volatile Flash memories, respectively. In the rest of the document, they will be referred to as M58WRxxxKU/L unless otherwise specified. The M58WRxxxKU/L may be erased electrically at block level and programmed in-system on a Word-by-Word basis using a 1.7 V to 2 V VDD supply for the circuitry and a 1.7 V to 2 V VDDQ supply for the Input/Output pins. An optional 9 V VPP power supply is provided to speed up customer programming. The first sixteen address lines are multiplexed with the Data Input/Output signals on the multiplexed address/data bus ADQ0-ADQ15. The remaining address lines, A16-Amax, are the Most Significant Bit addresses. The device features an asymmetrical block architecture: ● the M58WR016KU/L have an array of 39 blocks, and are divided into 4 Mbit banks. There are 3 banks each containing 8 main blocks of 32 Kwords, and one parameter bank containing 8 parameter blocks of 4 Kwords and 7 main blocks of 32 Kwords. ● the M58WR032KU/L have an array of 71 blocks, and are divided into 4 Mbit banks. There are 7 banks each containing 8 main blocks of 32 Kwords, and one parameter bank containing 8 parameter blocks of 4 Kwords and 7 main blocks of 32 Kwords. ● the M58WR064KU/L have an array of 135 blocks, and are divided into 4 Mbit banks. There are 15 banks each containing 8 main blocks of 32 Kwords, and one parameter bank containing 8 parameter blocks of 4 Kwords and 7 main blocks of 32 Kwords. The Multiple Bank Architecture allows Dual Operations, while programming or erasing in one bank, Read operations are possible in other banks. Only one bank at a time is allowed to be in Program or Erase mode. It is possible to perform burst reads that cross bank boundaries. The bank architectures are summarized in Tables 2, 3 and 4, and the memory maps are shown in Figures 3, 4 and 5. The Parameter Blocks are located at the top of the memory address space for the M58WR016KU, M58WR032KU and M58WR064KU, and at the bottom for the M58WR016KL, M58WR032KL and M58WR064KL. Each block can be erased separately. Erase can be suspended, in order to perform program in any other block, and then resumed. Program can be suspended to read data in any other block and then resumed. Each block can be programmed and erased over 100,000 cycles using the supply voltage VDD. There are two Enhanced Factory programming commands available to speed up programming. Program and Erase commands are written to the Command Interface of the memory. An internal Program/Erase Controller takes care of the timings necessary for program and erase operations. The end of a program or erase operation can be detected and any error conditions identified in the Status Register. The command set required to control the memory is consistent with JEDEC standards. The device supports synchronous burst read and asynchronous read from all blocks of the memory array; at power-up the device is configured for asynchronous read. In synchronous burst mode, data is output on each clock cycle at frequencies of up to 86 MHz. The synchronous burst read operation can be suspended and resumed. 9/123 Description M58WRxxxKU, M58WRxxxKL The device features an Automatic Standby mode. When the bus is inactive during Asynchronous Read operations, the device automatically switches to the Automatic Standby mode. In this condition the power consumption is reduced to the standby value IDD4 and the outputs are still driven. The M58WRxxxKU/L features an instant, individual block locking scheme that allows any block to be locked or unlocked with no latency, enabling instant code and data protection. All blocks have three levels of protection. They can be locked and locked-down individually preventing any accidental programming or erasure. There is an additional hardware protection against program and erase. When VPP ≤VPPLK all blocks are protected against program or erase. All blocks are locked at Power- Up. The device includes a Protection Register to increase the protection of a system’s design. The Protection Register is divided into two segments: a 64 bit segment containing a unique device number written by Numonyx, and a 128 bit segment One-Time-Programmable (OTP) by the user. The user programmable segment can be permanently protected. Figure 6, shows the Protection Register memory map. The memory is available in a VFBGA44 7.5 × 5 mm, 10 × 4 active ball array, 0.5 mm pitch package. It is supplied with all the bits erased (set to ’1’). 10/123 M58WRxxxKU, M58WRxxxKL Figure 1. Description Logic diagram VDD VDDQ VPP 16 A16-Amax(1) ADQ0-ADQ15 W E M58WR016KU M58WR016KL M58WR032KU M58WR032KL M58WR064KU M58WR064KL G RP WP WAIT BINV L K VSS VSSQ AI13519 1. Amax is equal to A19 in the M58WR016KU/L, to A20 in the M58WR032KU/L, and to A21 in the M58WR064KU/L. Table 1. Signal names Name Description Direction A16-Amax(1) Address inputs ADQ0-ADQ15 Data input/outputs or Address inputs, Command inputs E Chip Enable Input G Output Enable Input W Write Enable Input RP Reset/Power-Down Input WP Write Protect Input K Clock Input L Latch Enable Input WAIT Wait BINV Bus Invert VDD Supply voltage VDDQ Supply voltage for input/output buffers VPP Optional supply voltage for Fast Program & Erase VSS Ground VSSQ Ground input/output supply NC Not connected internally Inputs I/O Output I/O 1. Amax is equal to A19 in the M58WR016KU/L, to A20 in the M58WR032KU/L, and to A21 in the M58WR064KU/L. 11/123 12/123 VSS ADQ15 E F H ADQ14 ADQ7 A16 A21/ NC(1) 4 VSSQ ADQ5 ADQ4 ADQ12 ADQ13 ADQ6 BINV L A20/ NC(1) VDD 7 K 6 VSS 5 ADQ11 ADQ3 RP W 8 ADQ10 ADQ2 WP VPP 9 VDDQ ADQ9 A18 A19 10 ADQ1 ADQ8 E A17 11 Note1: Ball D5 is A20 in the M58WR032KU/L and M58WR064KU/L, it is Not Connected internally (NC) in the M58WR016KU/L. Ball C4 is A21 in the M58WR064KU/L, it is Not Connected internally (NC) in the M58WR016KU/L and M58WR032KU/L. VDDQ D G WAIT 3 C NC NC 2 ADQ0 G VSSQ NC 12 13 NC NC 14 AI13520 Figure 2. B A 1 Description M58WRxxxKU, M58WRxxxKL VFBGA44 connections (top view through package) M58WRxxxKU, M58WRxxxKL Table 2. Description M58WR016KU/L bank architecture Number Bank Size Parameter Blocks Main Blocks Parameter Bank 4 Mbit 8 blocks of 4 Kword 7 blocks of 32 Kword Bank 1 4 Mbit - 8 blocks of 32 Kword Bank 2 4 Mbit - 8 blocks of 32 Kword Bank 3 4 Mbit - 8 blocks of 32 Kword Table 3. M58WR032KU/L bank architecture Parameter Bank 4 Mbit 8 blocks of 4 Kword 7 blocks of 32 Kword Bank 1 4 Mbit - 8 blocks of 32 Kword Bank 2 4 Mbit - 8 blocks of 32 Kword Bank 3 4 Mbit - 8 blocks of 32 Kword ---- Main Blocks ---- Parameter Blocks ---- Bank Size ---- Number Bank 6 4 Mbit - 8 blocks of 32 Kword Bank 7 4 Mbit - 8 blocks of 32 Kword Table 4. M58WR064KU/L bank architecture Parameter Bank 4 Mbit 8 blocks of 4 Kword 7 blocks of 32 Kword Bank 1 4 Mbit - 8 blocks of 32 Kword Bank 2 4 Mbit - 8 blocks of 32 Kword Bank 3 4 Mbit - 8 blocks of 32 Kword ---- Main Blocks ---- Parameter Blocks ---- Bank Size ---- Number Bank 14 4 Mbit - 8 blocks of 32 Kword Bank 15 4 Mbit - 8 blocks of 32 Kword 13/123 Description M58WRxxxKU, M58WRxxxKL Figure 3. M58WR016KU/L memory map M58WR016KL - Bottom Boot Block Address lines ADQ0-ADQ15 and A16-A19 M58WR016KU - Top Boot Block Address lines ADQ0-ADQ15 and A16-A19 00000h 07FFFh 8 Main Blocks Bank 3 38000h 3FFFFh 40000h 47FFFh 32 KWord 8 Main Blocks 32 KWord 8 Main Blocks Parameter Bank F0000h F7FFFh F8000h F8FFFh FF000h FFFFFh 78000h 7FFFFh 80000h 87FFFh 32 KWord B8000h BFFFFh C0000h C7FFFh 4 KWord 4 KWord 8 Parameter Blocks 4KWord 32 KWord 7 Main Blocks 32 KWord 32 KWord 8 Main Blocks 32 KWord 32 KWord 8 Main Blocks Bank 2 32 KWord 8 Parameter Blocks 4 KWord Bank 1 32 KWord 7 Main Blocks 07000h 07FFFh 08000h 0FFFFh 38000h 3FFFFh 40000h 47FFFh 32 KWord Bank 1 B8000h BFFFFh C0000h C7FFFh Parameter Bank 32 KWord Bank 2 78000h 7FFFFh 80000h 87FFFh 00000h 00FFFh 32 KWord 32 KWord 32 KWord 8 Main Blocks Bank 3 F8000h FFFFFh 32 KWord AI13521 14/123 M58WRxxxKU, M58WRxxxKL Figure 4. Description M58WR032KU/L memory map M58WR032KL - Bottom Boot Block Address lines A20-A16 and ADQ15-ADQ0 M58WR032KU - Top Boot Block Address lines A20-A16 and ADQ15-ADQ0 000000h 007FFFh 32 KWord 038000h 03FFFFh 32 KWord Bank 7 100000h 107FFFh 8 Main Blocks Parameter Bank 1F0000h 1F7FFFh 1F8000h 1F8FFFh 1FF000h 1FFFFFh 8 Parameter Blocks 4KWord 32 KWord 7 Main Blocks 32 KWord 32 KWord 8 Main Blocks 32 KWord 32 KWord 8 Main Blocks Bank 2 0B8000h 0BFFFFh 0C0000h 0C7FFFh 32 KWord Bank 1 1B8000h 1BFFFFh 1C0000h 1C7FFFh 078000h 07FFFFh 080000h 087FFFh 32 KWord 8 Main Blocks 4 KWord Bank 1 32 KWord 8 Main Blocks 007000h 007FFFh 008000h 00FFFFh 038000h 03FFFFh 040000h 047FFFh 32 KWord Bank 2 178000h 17FFFFh 180000h 187FFFh Parameter Bank 32 KWord Bank 3 138000h 13FFFFh 140000h 147FFFh 000000h 000FFFh 8 Main Blocks 32 KWord 32 KWord 8 Main Blocks Bank 3 32 KWord 0F8000h 0FFFFFh 32 KWord 1C0000h 1C7FFFh 32 KWord 1F8000h 1FFFFFh 32 KWord 32 KWord 7 Main Blocks 32 KWord 4 KWord 8 Parameter Blocks 4 KWord 8 Main Blocks Bank 7 AI10158 15/123 Description M58WRxxxKU, M58WRxxxKL Figure 5. M58WR064KU/L memory map M58WR064KU - Top Boot Block Address lines A21-A16 and ADQ15-ADQ0 M58WR064KL - Bottom Boot Block Address lines A21-A16 and ADQ15-ADQ0 000000h 007FFFh 32 KWord 000000h 000FFFh 038000h 03FFFFh 32 KWord 8 Main Blocks Bank 15 300000h 307FFFh 8 Main Blocks 378000h 37FFFFh 380000h 387FFFh Parameter Bank 3F0000h 3F7FFFh 3F8000h 3F8FFFh 3FF000h 3FFFFFh 0B8000h 0BFFFFh 0C0000h 0C7FFFh 32 KWord 8 Main Blocks 4KWord 32 KWord 7 Main Blocks 32 KWord 32 KWord 8 Main Blocks 32 KWord 32 KWord 8 Main Blocks Bank 2 32 KWord Bank 1 3B8000h 3BFFFFh 3C0000h 3C7FFFh 078000h 07FFFFh 080000h 087FFFh 32 KWord 8 Main Blocks 8 Parameter Blocks Bank 1 32 KWord Bank 2 007000h 007FFFh 008000h 00FFFFh 038000h 03FFFFh 040000h 047FFFh 32 KWord Bank 3 338000h 33FFFFh 340000h 347FFFh Parameter Bank 4 KWord 32 KWord 32 KWord 8 Main Blocks Bank 3 32 KWord 0F8000h 0FFFFFh 32 KWord 3C0000h 3C7FFFh 32 KWord 3F8000h 3FFFFFh 32 KWord 32 KWord 7 Main Blocks 32 KWord 4 KWord 8 Parameter Blocks Bank 15 4 KWord 8 Main Blocks AI13456 16/123 M58WRxxxKU, M58WRxxxKL 2 Signal descriptions Signal descriptions See Figure 1: Logic diagram and Table 1: Signal names, for a brief overview of the signals connected to this device. 2.1 Address inputs (ADQ0-ADQ15, A16-Amax) Amax is equal to A19 in the M58WR016KU/L, to A20 in the M58WR032KU/L, and to A21 in the M58WR064KU/L. The Address Inputs select the cells in the memory array to access during Bus Read operations. During Bus Write operations they control the commands sent to the Command Interface of the Program/Erase Controller. 2.2 Data input/output (ADQ0-ADQ15) The Data I/O outputs the data stored at the selected address during a Bus Read operation or inputs a command or the data to be programmed during a Bus Write operation. 2.3 Chip Enable (E) The Chip Enable input activates the memory control logic, input buffers, decoders and sense amplifiers. When Chip Enable is at VILand Reset is at VIH the device is in active mode. When Chip Enable is at VIH the memory is deselected, the outputs are high impedance and the power consumption is reduced to the standby level. 2.4 Output Enable (G) The Output Enable controls data outputs during the Bus Read operation of the memory. 2.5 Write Enable (W) The Write Enable controls the Bus Write operation of the memory’s Command Interface. The data is latched on the rising edge of Chip Enable or Write Enable whichever occurs first. 2.6 Write Protect (WP) Write Protect is an input that gives an additional hardware protection for each block. When Write Protect is at VIL, the Lock-Down is enabled and the protection status of the LockedDown blocks cannot be changed. When Write Protect is at VIH, the Lock-Down is disabled and the Locked-Down blocks can be locked or unlocked. (refer to Table 17: Lock status). 17/123 Signal descriptions 2.7 M58WRxxxKU, M58WRxxxKL Reset/Power-Down (RP) The Reset/Power-Down input provides a hardware reset of the memory, and/or power-down functions, depending on the settings in the Configuration Register. When Reset/PowerDown is at VIL, the memory is in reset mode: the outputs are high impedance and the current consumption is reduced to the Standby Supply Current IDD3, or to the Reset/PowerDown Supply Current IDD2 if the Power-Down function is enabled. Refer to Table 22: DC characteristics - currents, for the value of IDD2 and IDD3. After reset all blocks are in the Locked state and the bits of the Configuration Register are reset except for Power-Down bit CR5. When Reset/Power-Down is at VIH, the device is in normal operation. Exiting reset mode the device enters Asynchronous Read mode, but a negative transition of Chip Enable or Latch Enable is required to ensure valid data outputs. 2.8 Latch Enable (L) Latch Enable latches the ADQ0-ADQ15 and A16-Amax address bits on its rising edge. The address latch is transparent when Latch Enable is at VIL and it is inhibited when Latch Enable is at VIH. 2.9 Clock (K) The clock input synchronizes the memory to the microcontroller during synchronous read operations; the address is latched on a Clock edge (rising or falling, according to the configuration settings) when Latch Enable is at VIL. Clock is don't care during asynchronous read and in write operations. 2.10 Wait (WAIT) Wait is an output signal used during synchronous read to indicate whether the data on the output bus are valid. This output is high impedance when Chip Enable is at VIH or Reset is at VIL. It can be configured to be active during the wait cycle or one clock cycle in advance. The WAIT signal is forced deasserted when Output Enable is at VIH. 2.11 Bus Invert (BINV) Bus invert is an input/output signal used to reduce the amount of power required to switch the external address/data bus. Power is saved by inverting the data on ADQ0-ADQ15 each time the inversion results in a reduced number of pin transitions. Data is inverted when BINV is at VIH (i.e. if the data is AAAAh and BINV is at VIH, AAAAh becomes 5555h). BINV is high impedance when Chip Enable or Output Enable is at VIH or when Reset/Power Down is at VIL. 2.12 VDD supply voltage VDD provides the power supply to the internal core of the memory device. It is the main power supply for all operations (Read, Program and Erase). 18/123 M58WRxxxKU, M58WRxxxKL 2.13 Signal descriptions VDDQ supply voltage VDDQ provides the power supply to the I/O pins and enables all Outputs to be powered independently from VDD. VDDQ can be tied to VDD or can use a separate supply. 2.14 VPP Program supply voltage VPP is both a control input and a power supply pin. The two functions are selected by the voltage range applied to the pin. If VPP is kept in a low voltage range (0 V to VDDQ) VPP is seen as a control input. In this case a voltage lower than VPPLK gives an absolute protection against program or erase, while VPP in the VPP1 range enables these functions (see Tables 22 and 23, DC Characteristics for the relevant values). VPP is only sampled at the beginning of a program or erase; a change in its value after the operation has started does not have any effect and program or erase operations continue. If VPP is in the range of VPPH it acts as a power supply pin. In this condition VPP must be stable until the Program/Erase algorithm is completed. 2.15 VSS ground VSS ground is the reference for the core supply. It must be connected to the system ground. 2.16 VSSQ ground VSSQ ground is the reference for the input/output circuitry driven by VDDQ. VSSQ must be connected to VSS. Note: Each device in a system should have VDD, VDDQ and VPP decoupled with a 0.1 µF ceramic capacitor close to the pin (high frequency, inherently low inductance capacitors should be as close as possible to the package). See Figure 10: AC measurement load circuit. The PCB track widths should be sufficient to carry the required VPP program and erase currents. 19/123 Bus operations 3 M58WRxxxKU, M58WRxxxKL Bus operations There are six standard bus operations that control the device. These are Bus Read, Bus Write, Address Latch, Output Disable, Standby and Reset. See Table 5: Bus operations, for a summary. Typically glitches of less than 5ns on Chip Enable or Write Enable are ignored by the memory and do not affect Bus Write operations. 3.1 Bus Read Bus Read operations are used to output the contents of the Memory Array, the Electronic Signature, the Status Register and the Common Flash Interface. Both Chip Enable and Output Enable must be at VIL in order to perform a read operation. The Chip Enable input should be used to enable the device. Output Enable should be used to gate data onto the output. The data read depends on the previous command written to the memory (see Command Interface section). See Figures 11, 12 and 13 Read AC Waveforms, and Tables 24 and 25 Read AC Characteristics, for details of when the output becomes valid. 3.2 Bus Write Bus Write operations write Commands to the memory or latch Input Data to be programmed. A bus write operation is initiated when Chip Enable and Write Enable are at VIL with Output Enable at VIH. Commands and Input Data are latched on the rising edge of Write Enable or Chip Enable, whichever occurs first. The addresses must also be latched prior to the write operation by toggling Latch Enable (when Chip Enable is at VIL). The Latch Enable must be tied to VIH during the bus write operation. See Figures 16 and 17, Write AC Waveforms, and Tables 26 and 27, Write AC Characteristics, for details of the timing requirements. 3.3 Address Latch Address latch operations input valid addresses. Both Chip enable and Latch Enable must be at VIL during address latch operations. The addresses are latched on the rising edge of Latch Enable. 3.4 Output Disable The outputs are high impedance when the Output Enable is at VIH. 20/123 M58WRxxxKU, M58WRxxxKL 3.5 Bus operations Standby Standby disables most of the internal circuitry allowing a substantial reduction of the current consumption. The memory is in standby when Chip Enable and Reset are at VIH. The power consumption is reduced to the standby level and the outputs are set to high impedance, independently from the Output Enable or Write Enable inputs. If Chip Enable switches to VIH during a program or erase operation, the device enters Standby mode when finished. 3.6 Reset/Power-Down During reset mode the memory is deselected and the outputs are high impedance. The memory is in reset mode when Reset/Power-Down is at VIL. The power consumption is reduced to the Standby level, or to the Reset/Power-Down level if the Power-Down function is enabled, independently of the Chip Enable, Output Enable or Write Enable inputs. If Reset/Power-Down is pulled to VSS during a Program or Erase, this operation is aborted and the memory content is no longer valid. Table 5. Bus operations Operation WAIT(1) E G W L RP Bus Read VIL VIL VIH VIH VIH Data Output Bus Write VIL VIH VIL VIH VIH Data Input Address Latch VIL VIH x VIL VIH Address Input Output Disable VIL VIH VIH VIH VIH Hi-Z VIH X(2) X X VIH Hi-Z Hi-Z X X X X VIL Hi-Z Hi-Z Standby Reset/PowerDown ADQ15-ADQ0 1. WAIT signal polarity is configured using the Set Configuration Register command. 2. X = Don't care. 21/123 Command interface 4 M58WRxxxKU, M58WRxxxKL Command interface All Bus Write operations to the memory are interpreted by the Command Interface. Commands consist of one or more sequential Bus Write operations. An internal Program/Erase Controller handles all timings and verifies the correct execution of the Program and Erase commands. The Program/Erase Controller provides a Status Register whose output may be read at any time to monitor the progress or the result of the operation. The Command Interface is reset to read mode when power is first applied, when exiting from Reset or whenever VDD is lower than VLKO. Command sequences must be followed exactly. Any invalid combination of commands will be ignored. Refer to Table 6: Command codes, and Appendix D, Tables 47, 48, 49 and 50, Command Interface States - Modify and Lock Tables, for a summary of the Command Interface. The Command Interface is split into two types of commands: Standard commands and Factory Program commands. The following sections explain in detail how to perform each command. Table 6. Command codes Hex Code 22/123 Command 01h Block Lock Confirm 03h Set Configuration Register Confirm 10h Alternative Program Setup 20h Block Erase Setup 2Fh Block Lock-Down Confirm 30h Enhanced Factory Program Setup 35h Double Word Program Setup 40h Program Setup 50h Clear Status Register 56h Quadruple Word Program Setup 60h Block Lock Setup, Block Unlock Setup, Block Lock Down Setup and Set Configuration Register Setup 70h Read Status Register 75h Quadruple Enhanced Factory Program Setup 90h Read Electronic Signature 98h Read CFI Query B0h Program/Erase Suspend C0h Protection Register Program D0h Program/Erase Resume, Block Erase Confirm, Block Unlock Confirm or Enhanced Factory Program Confirm FFh Read Array M58WRxxxKU, M58WRxxxKL 5 Command interface - Standard commands Command interface - Standard commands The following commands are the basic commands used to read, write to and configure the device. Refer to Table 7: Standard commands, in conjunction with the following text descriptions. 5.1 Read Array command The Read Array command returns the addressed bank to Read Array mode. One Bus Write cycle is required to issue the Read Array command and return the addressed bank to Read Array mode. Subsequent read operations will read the addressed location and output the data. A Read Array command can be issued in one bank while programming or erasing in another bank. However if a Read Array command is issued to a bank currently executing a Program or Erase operation the command will be executed but the output data is not guaranteed. 5.2 Read Status Register command The Status Register indicates when a Program or Erase operation is complete and the success or failure of operation itself. Issue a Read Status Register command to read the Status Register content. The Read Status Register command can be issued at any time, even during Program or Erase operations. The following read operations output the content of the Status Register of the addressed bank. The Status Register is latched on the falling edge of E or G signals, and can be read until E or G returns to VIH. Either E or G must be toggled to update the latched data. See Table 10 for the description of the Status Register Bits. This mode supports asynchronous or single synchronous reads only. 5.3 Read Electronic Signature command The Read Electronic Signature command reads the Manufacturer and Device Codes, the Block Locking Status, the Protection Register, and the Configuration Register. The Read Electronic Signature command consists of one write cycle to an address within one of the banks. A subsequent Read operation in the same bank will output the Manufacturer Code, the Device Code, the protection Status of the blocks in the targeted bank, the Protection Register, or the Configuration Register (see Table 8). The Read Electronic Signature command can be issued at any time, even during program or erase operations, except during Protection Register Program operations. Dual operations between the Parameter bank and the Electronic Signature location are not allowed (see Table 16: Dual operation limitations for details). If a Read Electronic Signature command is issued in a bank that is executing a Program or Erase operation the bank will go into Read Electronic Signature mode, subsequent Bus Read cycles will output the Electronic Signature data and the Program/Erase controller will continue to program or erase in the background. This mode supports asynchronous or single synchronous reads only, it does not support synchronous burst reads. 23/123 Command interface - Standard commands 5.4 M58WRxxxKU, M58WRxxxKL Read CFI Query command The Read CFI Query command is used to read data from the Common Flash Interface (CFI). The Read CFI Query Command consists of one Bus Write cycle, to an address within one of the banks. Once the command is issued subsequent Bus Read operations in the same bank read from the Common Flash Interface. If a Read CFI Query command is issued in a bank that is executing a Program or Erase operation the bank will go into Read CFI Query mode, subsequent Bus Read cycles will output the CFI data and the Program/Erase controller will continue to Program or Erase in the background. This mode supports asynchronous or single synchronous reads only, it does not support synchronous burst reads. The status of the other banks is not affected by the command (see Table 14). After issuing a Read CFI Query command, a Read Array command should be issued to the addressed bank to return the bank to Read Array mode. Dual operations between the Parameter Bank and the CFI memory space are not allowed (see Table 16: Dual operation limitations). See Appendix B: Common Flash Interface, Tables 37, 38, 39, 40, 41, 42, 43, 44, 45 and 46 for details on the information contained in the Common Flash Interface memory area. 5.5 Clear Status Register command The Clear Status Register command can be used to reset (set to ‘0’) error bits SR1, SR3, SR4 and SR5 in the Status Register. One bus write cycle is required to issue the Clear Status Register command. After the Clear Status Register command the bank returns to read mode. The error bits in the Status Register do not automatically return to ‘0’ when a new command is issued. The error bits in the Status Register should be cleared before attempting a new Program or Erase command. 24/123 M58WRxxxKU, M58WRxxxKL 5.6 Command interface - Standard commands Block Erase command The Block Erase command can be used to erase a block. It sets all the bits within the selected block to ’1’. All previous data in the block is lost. If the block is protected then the Erase operation will abort, the data in the block will not be changed and the Status Register will output the error. The Block Erase command can be issued at any moment, regardless of whether the block has been programmed or not. Two Bus Write cycles are required to issue the command. ● The first bus cycle sets up the Erase command. ● The second latches the block address in the Program/Erase Controller and starts it. If the second bus cycle is not Write Erase Confirm (D0h), Status Register bits SR4 and SR5 are set and the command aborts. Erase aborts if Reset turns to VIL. As data integrity cannot be guaranteed when the Erase operation is aborted, the block must be erased again. Once the command is issued the device outputs the Status Register data when any address within the bank is read. At the end of the operation the bank will remain in Read Status Register mode until a Read Array, Read CFI Query or Read Electronic Signature command is issued. During Erase operations the bank containing the block being erased will only accept the Read Array, Read Status Register, Read Electronic Signature, Read CFI Query and the Program/Erase Suspend command, all other commands will be ignored. Refer to Dual Operations section for detailed information about simultaneous operations allowed in banks not being erased. Typical Erase times are given in Table 18: Program, erase times and endurance cycles. See Appendix C, Figure 24: Block Erase flowchart and pseudocode, for a suggested flowchart for using the Block Erase command. 5.7 Program command The memory array can be programmed word-by-word. Only one Word in one bank can be programmed at any one time. If the block is protected then the Program operation will abort, the data in the block will not be changed and the Status Register will output the error. Two bus write cycles are required to issue the Program Command. ● The first bus cycle sets up the Program command. ● The second latches the Address and the Data to be written and starts the Program/Erase Controller. After programming has started, read operations in the bank being programmed output the Status Register content. During Program operations the bank being programmed will only accept the Read Array, Read Status Register, Read Electronic Signature, Read CFI Query and the Program/Erase Suspend command. Refer to Dual Operations section for detailed information about simultaneous operations allowed in banks not being programmed. Typical Program times are given in Table 18: Program, erase times and endurance cycles. Programming aborts if Reset goes to VIL. As data integrity cannot be guaranteed when the program operation is aborted, the memory location must be reprogrammed. See Appendix C, Figure 20: Program flowchart and pseudocode, for the flowchart for using the Program command. 25/123 Command interface - Standard commands 5.8 M58WRxxxKU, M58WRxxxKL Program/Erase Suspend command The Program/Erase Suspend command is used to pause a Program or Block Erase operation. One bus write cycle is required to issue the Program/Erase Suspend command. Once the Program/Erase Controller has paused bits SR7, SR6 and/ or SR2 of the Status Register will be set to ‘1’. The command can be addressed to any bank. During Program/Erase Suspend the Command Interface will accept the Program/Erase Resume, Read Array (cannot read the suspended block), Read Status Register, Read Electronic Signature and Read CFI Query commands. Additionally, if the suspend operation was Erase then the Clear Status Register, Set Configuration Register, Program, Block Lock, Block Lock-Down or Block Unlock command will also be accepted. The block being erased may be protected by issuing the Block Lock or Block Lock-Down commands. Only the blocks not being erased may be read or programmed correctly. When the Program/Erase Resume command is issued the operation will complete. Refer to the Dual Operations section for detailed information about simultaneous operations allowed during Program/Erase Suspend. During a Program/Erase Suspend, the device can be placed in standby mode by taking Chip Enable to VIH. Program/Erase is aborted if Reset turns to VIL. See Appendix C, Figure 23: Program Suspend & Resume flowchart and pseudocode, and Figure 25: Erase Suspend & Resume flowchart and pseudocode, for flowcharts for using the Program/Erase Suspend command. 5.9 Program/Erase Resume command The Program/Erase Resume command can be used to restart the Program/Erase Controller after a Program/Erase Suspend command has paused it. One Bus Write cycle is required to issue the command. The command can be written to any address. The Program/Erase Resume command does not change the read mode of the banks. If the suspended bank was in Read Status Register, Read Electronic signature or Read CFI Query mode the bank remains in that mode and outputs the corresponding data. If the bank was in Read Array mode subsequent read operations will output invalid data. If a Program command is issued during a Block Erase Suspend, then the erase cannot be resumed until the programming operation has completed. It is possible to accumulate suspend operations. For example: suspend an erase operation, start a programming operation, suspend the programming operation then read the array. See Appendix C, Figure 23: Program Suspend & Resume flowchart and pseudocode, and Figure 25: Erase Suspend & Resume flowchart and pseudocode, for flowcharts for using the Program/Erase Resume command. 26/123 M58WRxxxKU, M58WRxxxKL 5.10 Command interface - Standard commands Protection Register Program command The Protection Register Program command is used to Program the 128 bit user One-TimeProgrammable (OTP) segment of the Protection Register and the Protection Register Lock. The segment is programmed 16 bits at a time. When shipped all bits in the segment are set to ‘1’. The user can only program the bits to ‘0’. Two write cycles are required to issue the Protection Register Program command. ● The first bus cycle sets up the Protection Register Program command. ● The second latches the Address and the Data to be written to the Protection Register and starts the Program/Erase Controller. Read operations output the Status Register content after the programming has started. The segment can be protected by programming bit 1 of the Protection Lock Register (Figure 6: Protection Register memory map). Attempting to program a previously protected Protection Register will result in a Status Register error. The protection of the Protection Register is not reversible. The Protection Register Program cannot be suspended. Dual operations between the Parameter Bank and the Protection Register memory space are not allowed (see Table 16: Dual operation limitations for details). See Appendix C, Figure 27: Protection Register Program flowchart and pseudocode, for a flowchart for using the Protection Register Program command. 5.11 Set Configuration Register command The Set Configuration Register command is used to write a new value to the Configuration Register which defines the burst length, type, X latency, Synchronous/Asynchronous Read mode and the valid Clock edge configuration. Two Bus Write cycles are required to issue the Set Configuration Register command. ● The first cycle writes the setup command and the address corresponding to the Configuration Register content. ● The second cycle writes the Configuration Register data and the confirm command. Once the command is issued the memory returns to Read mode. The values of the Configuration Register must always be presented on ADQ15-ADQ0. CR0 is on ADQ0, CR1 on ADQ1, etc.; the other address bits are ignored. 27/123 Command interface - Standard commands 5.12 M58WRxxxKU, M58WRxxxKL Block Lock command The Block Lock command is used to lock a block and prevent Program or Erase operations from changing the data in it. All blocks are locked at power-up or reset. Two Bus Write cycles are required to issue the Block Lock command. ● The first bus cycle sets up the Block Lock command. ● The second Bus Write cycle latches the block address. The lock status can be monitored for each block using the Read Electronic Signature command. Table 17 shows the Lock Status after issuing a Block Lock command. The Block Lock bits are volatile, once set they remain set until a hardware reset or powerdown/power-up. They are cleared by a Block Unlock command. Refer to the section, Block Locking, for a detailed explanation. See Appendix C, Figure 26: Locking operations flowchart and pseudocode, for a flowchart for using the Lock command. 5.13 Block Unlock command The Block Unlock command is used to unlock a block, allowing the block to be programmed or erased. Two Bus Write cycles are required to issue the Block Unlock command. ● The first bus cycle sets up the Block Unlock command. ● The second Bus Write cycle latches the block address. The lock status can be monitored for each block using the Read Electronic Signature command. Table 17 shows the protection status after issuing a Block Unlock command. Refer to the section, Block Locking, for a detailed explanation and Appendix C, Figure 26: Locking operations flowchart and pseudocode, for a flowchart for using the Unlock command. 5.14 Block Lock-Down command A locked or unlocked block can be locked-down by issuing the Block Lock-Down command. A locked-down block cannot be programmed or erased, or have its protection status changed when WP is low, VIL. When WP is high, VIH, the Lock-Down function is disabled and the locked blocks can be individually unlocked by the Block Unlock command. Two Bus Write cycles are required to issue the Block Lock-Down command. ● The first bus cycle sets up the Block Lock command. ● The second Bus Write cycle latches the block address. The lock status can be monitored for each block using the Read Electronic Signature command. Locked-Down blocks revert to the locked (and not locked-down) state when the device is reset on power-down. Table 17 shows the Lock Status after issuing a Block LockDown command. Refer to the section, Block Locking, for a detailed explanation and Appendix C, Figure 26: Locking operations flowchart and pseudocode, for a flowchart for using the Lock-Down command. 28/123 M58WRxxxKU, M58WRxxxKL Table 7. Command interface - Standard commands Standard commands Commands Cycles Bus operations 1st Cycle 2nd Cycle Op. Add Data Op. Add Data Read Array 1+ Write BKA FFh Read WA RD Read Status Register 1+ Write BKA 70h Read BKA(1) SRD Read (1) BKA ESD Read BKA(1) QD Read Electronic Signature 1+ Write BKA 90h Read CFI Query 1+ Write BKA 98h Clear Status Register 1 Write X 50h Block Erase 2 Write BKA or BA(2) 20h Write BA D0h Program 2 Write BKA or WA(2) 40h or 10h Write WA PD Program/Erase Suspend 1 Write X(3) B0h Program/Erase Resume 1 Write X D0h Protection Register Program 2 Write PRA C0h Write PRA PRD Set Configuration Register 2 Write CRD 60h Write CRD 03h Block Lock 2 Write BKA or BA(2) 60h Write BA 01h Block Unlock 2 Write BKA or BA(2) 60h Write BA D0h Block Lock-Down 2 Write BKA or BA(2) 60h Write BA 2Fh 1. Must be same bank as in the first cycle. The signature addresses are listed in Table 8 2. Any address within the bank can be used. 3. X = Don't Care, WA = Word Address in targeted bank, RD = Read Data, SRD = Status Register Data, ESD = Electronic Signature Data, QD = Query Data, BA = Block Address, BKA = Bank Address, PD = Program Data, PRA = Protection Register Address, PRD = Protection Register Data, CRD = Configuration Register Data. 29/123 Command interface - Standard commands Table 8. M58WRxxxKU, M58WRxxxKL Electronic signature codes Code Address (h) Data (h) Bank Address + 00 0020 Top Bank Address + 01 8823 (M58WR016KU) 8828 (M58WR032KU) 88C0 (M58WR064KU) Bottom Bank Address + 01 8824 (M58WR016KL) 8829 (M58WR032KL) 88C1 (M58WR064KL) Manufacturer Code Device Code Block Protection Locked 0001 Unlocked 0000 Locked and Locked-Down Block Address + 02 0003 Unlocked and LockedDown 0002 Die Revision Code Bank Address + 03 DRC(1) Configuration Register Bank Address + 05 CR(2) Numonyx Factory Default Protection Register Lock OTP Area Permanently Locked 0002 Bank Address + 80 0000 Bank Address + 81 Bank Address + 84 Unique Device Number Bank Address + 85 Bank Address + 8C OTP Area Protection Register 1. DRC = Die Revision Code 2. CR = Configuration Register Figure 6. Protection Register memory map PROTECTION REGISTER 8Ch User Programmable OTP 85h 84h Unique device number 81h 80h Protection Register Lock 1 0 AI08614 30/123 M58WRxxxKU, M58WRxxxKL 6 Command interface - Factory program commands Command interface - Factory program commands The Factory Program commands are used to speed up programming. They require VPP to be at VPPH. Refer to Table 9: Factory Program commands, in conjunction with the following text descriptions. 6.1 Double Word Program command The Double Word Program command improves the programming throughput by writing a page of two adjacent words in parallel. The two words must differ only for the address ADQ0. If the block is protected then the Double Word Program operation will abort, the data in the block will not be changed and the Status Register will output the error. If programming is attempted with VPP ≠ VPPH, the command is ignored. Three bus write cycles are necessary to issue the Double Word Program command. ● The first bus cycle sets up the Double Word Program Command. ● The second bus cycle latches the Address and the Data of the first word to be written. ● The third bus cycle latches the Address and the Data of the second word to be written and starts the Program/Erase Controller. Read operations in the bank being programmed output the Status Register content after the programming has started. During Double Word Program operations the bank being programmed will only accept the Read Array, Read Status Register, Read Electronic Signature and Read CFI Query command, all other commands will be ignored. Dual operations are not supported during Double Word Program operations and the command cannot be suspended. Typical Program times are given in Table 18: Program, erase times and endurance cycles. Programming aborts if Reset goes to VIL. As data integrity cannot be guaranteed when the program operation is aborted, the memory locations must be reprogrammed. See Appendix C, Figure 21: Double Word Program flowchart and pseudocode, for the flowchart for using the Double Word Program command. 31/123 Command interface - Factory program commands 6.2 M58WRxxxKU, M58WRxxxKL Quadruple Word Program command The Quadruple Word Program command improves the programming throughput by writing a page of four adjacent words in parallel. The four words must differ only for the addresses ADQ0 and ADQ1. If the block is protected then the Quadruple Word Program operation will abort, the data in the block will not be changed and the Status Register will output the error. If programming is attempted with VPP ≠ VPPH, the command is ignored. Five bus write cycles are necessary to issue the Quadruple Word Program command. ● The first bus cycle sets up the Double Word Program Command. ● The second bus cycle latches the Address and the Data of the first word to be written. ● The third bus cycle latches the Address and the Data of the second word to be written. ● The fourth bus cycle latches the Address and the Data of the third word to be written. ● The fifth bus cycle latches the Address and the Data of the fourth word to be written and starts the Program/Erase Controller. Read operations to the bank being programmed output the Status Register content after the programming has started. Programming aborts if Reset goes to VIL. As data integrity cannot be guaranteed when the program operation is aborted, the memory locations must be reprogrammed. During Quadruple Word Program operations the bank being programmed will only accept the Read Array, Read Status Register, Read Electronic Signature and Read CFI Query command, all other commands will be ignored. Dual operations are not supported during Quadruple Word Program operations and the command cannot be suspended. Typical Program times are given in Table 18: Program, erase times and endurance cycles. See Appendix C, Figure 22: Quadruple Word Program flowchart and pseudocode, for the flowchart for using the Quadruple Word Program command. 32/123 M58WRxxxKU, M58WRxxxKL 6.3 Command interface - Factory program commands Enhanced Factory Program command The Enhanced Factory Program command can be used to program large streams of data within any one block. It greatly reduces the total programming time when a large number of words are written to a block at any one time. The use of the Enhanced Factory Program command requires certain operating conditions. ● VPP must be set to VPPH ● VDD must be within operating range ● Ambient temperature TA must be 30°C ± 10°C ● The targeted block must be unlocked Dual operations are not supported during the Enhanced Factory Program operation and the command cannot be suspended. For optimum performance the Enhanced Factory Program commands should be limited to a maximum of 100 program/erase cycles per block. If this limit is exceeded the internal algorithm will continue to work properly but some degradation in performance is possible. Typical Program times are given in Table 18. If the block is protected then the Enhanced Factory Program operation will abort, the data in the block will not be changed and the Status Register will output the error. The Enhanced Factory Program command has four phases: the Setup Phase, the Program Phase to program the data to the memory, the Verify Phase to check that the data has been correctly programmed and reprogram if necessary and the Exit Phase. Refer to Table 9: Factory Program commands, and Figure 28: Enhanced Factory Program flowchart. 6.3.1 Setup Phase The Enhanced Factory Program command requires two Bus Write operations to initiate the command. ● The first bus cycle sets up the Enhanced Factory Program command. ● The second bus cycle confirms the command. The Status Register P/E.C. SR7 should be read to check that the P/E.C. is ready. After the confirm command is issued, read operations output the Status Register data. The read Status Register command must not be issued as it will be interpreted as data to program. 33/123 Command interface - Factory program commands 6.3.2 M58WRxxxKU, M58WRxxxKL Program Phase The Program Phase requires n+1 cycles, where n is the number of words (refer to Table 9: Factory Program commands and Figure 28: Enhanced Factory Program flowchart). Three successive steps are required to issue and execute the Program Phase of the command. 1. Use one Bus Write operation to latch the Start Address and the first word to be programmed. The Status Register Bank Write Status bit SR0 should be read to check that the P/E.C. is ready for the next word. 2. Each subsequent word to be programmed is latched with a new Bus Write operation. The address can either remain the Start Address, in which case the P/E.C. increments the address location or the address can be incremented in which case the P/E.C. jumps to the new address. If any address that is not in the same block as the Start Address is given with data FFFFh, the Program Phase terminates and the Verify Phase begins. The Status Register bit SR0 should be read between each Bus Write cycle to check that the P/E.C. is ready for the next word. 3. Finally, after all words have been programmed, write one Bus Write operation with data FFFFh to any address outside the block containing the Start Address, to terminate the programming phase. The memory is now set to enter the Verify Phase. 6.3.3 Verify Phase The Verify Phase is similar to the Program Phase in that all words must be resent to the memory for them to be checked against the programmed data. The Program/Erase Controller checks the stream of data with the data that was programmed in the Program Phase and reprograms the memory location if necessary. Three successive steps are required to execute the Verify Phase of the command. 1. Use one Bus Write operation to latch the Start Address and the first word, to be verified. The Status Register bit SR0 should be read to check that the Program/Erase Controller is ready for the next word. 2. Each subsequent word to be verified is latched with a new Bus Write operation. The words must be written in the same order as in the Program Phase. The address can remain the Start Address or be incremented. If any address that is not in the same block as the Start Address is given with data FFFFh, the Verify Phase terminates. Status Register bit SR0 should be read to check that the P/E.C. is ready for the next word. 3. Finally, after all words have been verified, write one Bus Write operation with data FFFFh to any address outside the block containing the Start Address, to terminate the Verify Phase. If the Verify Phase is successfully completed the memory remains in Read Status Register mode. If the Program/Erase Controller fails to reprogram a given location, the error will be signaled in the Status Register. 6.3.4 Exit Phase Status Register P/E.C. bit SR7 set to ‘1’ indicates that the device has returned to Read mode. A full Status Register check should be done to ensure that the block has been successfully programmed. See the section on the Status Register for more details. 34/123 M58WRxxxKU, M58WRxxxKL 6.4 Command interface - Factory program commands Quadruple Enhanced Factory Program command The Quadruple Enhanced Factory Program command can be used to program one or more pages of four adjacent words in parallel. The four words must differ only for the addresses ADQ0 and ADQ1. VPP must be set to VPPH during Quadruple Enhanced Factory Program. If the block is protected then the Quadruple Enhanced Factory Program operation will abort, the data in the block will not be changed and the Status Register will output the error. It has four phases: the Setup Phase, the Load Phase where the data is loaded into the buffer, the combined Program and Verify Phase where the loaded data is programmed to the memory and then automatically checked and reprogrammed if necessary and the Exit Phase. Unlike the Enhanced Factory Program it is not necessary to resubmit the data for the Verify Phase. The Load Phase and the Program and Verify Phase can be repeated to program any number of pages within the block. 6.4.1 Setup Phase The Quadruple Enhanced Factory Program command requires one Bus Write operation to initiate the load phase. After the setup command is issued, read operations output the Status Register data. The Read Status Register command must not be issued as it will be interpreted as data to program. 6.4.2 Load Phase The Load Phase requires 4 cycles to load the data (refer to Table 9: Factory Program commands and Figure 29: Quadruple enhanced factory program flowchart). Once the first word of each Page is written it is impossible to exit the Load phase until all four words have been written. Two successive steps are required to issue and execute the Load Phase of the Quadruple Enhanced Factory Program command. 1. Use one Bus Write operation to latch the Start Address and the first word of the first Page to be programmed. For subsequent Pages the first word address can remain the Start Address (in which case the next Page is programmed) or can be any address in the same block. If any address with data FFFFh is given that is not in the same block as the Start Address, the device enters the Exit Phase. For the first Load Phase Status Register bit SR7 should be read after the first word has been issued to check that the command has been accepted (bit SR7 set to ‘0’). This check is not required for subsequent Load Phases. 2. Each subsequent word to be programmed is latched with a new Bus Write operation. The address is only checked for the first word of each Page as the order of the words to be programmed is fixed. The memory is now set to enter the Program and Verify Phase. 35/123 Command interface - Factory program commands 6.4.3 M58WRxxxKU, M58WRxxxKL Program and Verify Phase In the Program and Verify Phase the four words that were loaded in the Load Phase are programmed in the memory array and then verified by the Program/Erase Controller. If any errors are found the Program/Erase Controller reprograms the location. During this phase the Status Register shows that the Program/Erase Controller is busy, Status Register bit SR7 set to ‘0’, and that the device is not waiting for new data, Status Register bit SR0 set to ‘1’. When Status Register bit SR0 is set to ‘0’ the Program and Verify phase has terminated. Once the Verify Phase has successfully completed subsequent pages in the same block can be loaded and programmed. The device returns to the beginning of the Load Phase by issuing one Bus Write operation to latch the Address and the first of the four new words to be programmed. 6.4.4 Exit Phase Finally, after all the pages have been programmed, write one Bus Write operation with data FFFFh to any address outside the block containing the Start Address, to terminate the Load and Program and Verify Phases. Status Register bit SR7 set to ‘1’ and bit SR0 set to ‘0’ indicate that the Quadruple Enhanced Factory Program command has terminated. A full Status Register check should be done to ensure that the block has been successfully programmed. See the section on the Status Register for more details. If the Program and Verify Phase has successfully completed the memory returns to Read mode. If the P/E.C. fails to program and reprogram a given location, the error will be signaled in the Status Register. 36/123 M58WRxxxKU, M58WRxxxKL Table 9. Command interface - Factory program commands Factory Program commands (1) Command Phase Cycles Bus Write operations 1st 2nd 3rd Final -1 Add Data Add Data Add Data Final Add Data Add Data WA3 PD3 WA4 PD4 Double Word Program(2) 3 BKA or WA1(3) 35h WA1 PD1 WA2 PD2 Quadruple Word Program(4) 5 BKA or WA1(3) 56h WA1 PD1 WA2 PD2 2+n BKA or (3) +1 WA1 30h BA or D0h WA1(7) PD1 WA1(6) WAn(8) PAn NOT FFFF h WA1(7)) n+1 WA1(7) PD1 WA2(8) PD2 WA3(8) PD3 WAn(8) PAn NOT FFFF h WA1(7) BKA or WA1(3) 75h WA1(7) PD1 WA2(9) PD2 WA3(9) PD3 WA4(9) PD4 WA4i(9) PD4i Setup, Enhanced Program Factory Program (5) Verify, Exit Setup, first Load First Program & Quadruple Verify Enhanced Subsequent Factory Loads Program (4)(5) 5 Automatic 4 WA1i(7) PD1i WA2i (9) Subsequent Program & Verify Exit PD2i WA3i (9) PD3i Automatic 1 NOT WA1(7) FFFFh 1. WA = Word Address in targeted bank, BKA = Bank Address, PD = Program Data, BA = Block Address. 2. Word Addresses 1 and 2 must be consecutive Addresses differing only for A0. 3. Any address within the bank can be used. 4. Word Addresses 1,2,3 and 4 must be consecutive Addresses differing only for A0 and A1. 5. A Bus Read must be done between each Write cycle where the data is programmed or verified to read the Status Register and check that the memory is ready to accept the next data. n = number of words, i = number of Pages to be programmed. 6. Any address within the block can be used. 7. WA1 is the Start Address. NOT WA1 is any address that is not in the same block as WA1. 8. Address can remain Starting Address WA1 or be incremented. 9. Address is only checked for the first word of each Page as the order to program the words in each page is fixed so subsequent words in each Page can be written to any address. 37/123 Status Register 7 M58WRxxxKU, M58WRxxxKL Status Register The Status Register provides information on the current or previous Program or Erase operations. Issue a Read Status Register command to read the contents of the Status Register, refer to Read Status Register Command section for more details. To output the contents, the Status Register is latched and updated on the falling edge of the Chip Enable or Output Enable signals and can be read until Chip Enable or Output Enable returns to VIH. The Status Register can only be read using single asynchronous or single synchronous reads. Bus Read operations from any address within the bank, always read the Status Register during Program and Erase operations. The various bits convey information about the status and any errors of the operation. Bits SR7, SR6, SR2 and SR0 give information on the status of the device and are set and reset by the device. Bits SR5, SR4, SR3 and SR1 give information on errors, they are set by the device but must be reset by issuing a Clear Status Register command or a hardware reset. If an error bit is set to ‘1’ the Status Register should be reset before issuing another command. SR7 to SR1 refer to the status of the device while SR0 refers to the status of the addressed bank. The bits in the Status Register are summarized in Table 10: Status Register bits. Refer to Table 10 in conjunction with the following text descriptions. 7.1 Program/Erase Controller Status bit (SR7) The Program/Erase Controller Status bit indicates whether the Program/Erase Controller is active or inactive in any bank. When the Program/Erase Controller Status bit is Low (set to ‘0’), the Program/Erase Controller is active; when the bit is High (set to ‘1’), the Program/Erase Controller is inactive, and the device is ready to process a new command. The Program/Erase Controller Status is Low immediately after a Program/Erase Suspend command is issued until the Program/Erase Controller pauses. After the Program/Erase Controller pauses the bit is High. During Program, Erase, operations the Program/Erase Controller Status bit can be polled to find the end of the operation. Other bits in the Status Register should not be tested until the Program/Erase Controller completes the operation and the bit is High. After the Program/Erase Controller completes its operation the Erase Status, Program Status, VPP Status and Block Lock Status bits should be tested for errors. 7.2 Erase Suspend Status bit (SR6) The Erase Suspend Status bit indicates that an Erase operation has been suspended or is going to be suspended in the addressed block. When the Erase Suspend Status bit is High (set to ‘1’), a Program/Erase Suspend command has been issued and the memory is waiting for a Program/Erase Resume command. The Erase Suspend Status should only be considered valid when the Program/Erase Controller Status bit is High (Program/Erase Controller inactive). SR7 is set within the Erase Suspend Latency time of the Program/Erase Suspend command being issued therefore the memory may still complete the operation rather than entering the Suspend mode. When a Program/Erase Resume command is issued the Erase Suspend Status bit returns Low. 38/123 M58WRxxxKU, M58WRxxxKL 7.3 Status Register Erase Status bit (SR5) The Erase Status bit can be used to identify if the memory has failed to verify that the block has erased correctly. When the Erase Status bit is High (set to ‘1’), the Program/Erase Controller has applied the maximum number of pulses to the block and still failed to verify that it has erased correctly. The Erase Status bit should be read once the Program/Erase Controller Status bit is High (Program/Erase Controller inactive). Once set High, the Erase Status bit can only be reset Low by a Clear Status Register command or a hardware reset. If set High it should be reset before a new Program or Erase command is issued, otherwise the new command will appear to fail. 7.4 Program Status bit (SR4) The Program Status bit is used to identify either a Program failure, or an attempt to program a ‘1’ to an already programmed bit when VPP = VPPH. When the Program Status bit goes High (set to ‘1’) after a Program failure, the Program/Erase Controller has applied the maximum number of pulses to the byte and still failed to verify that it has programmed correctly. After an attempt to program a ‘1’ to an already programmed bit, the Program Status bit SR4 only goes High (set to ’1’) if VPP = VPPH (if VPP ≠ VPPH, SR4 remains Low (set to ‘0’) and the attempt is not shown). The Program Status bit should be read once the Program/Erase Controller Status bit is High (Program/Erase Controller inactive). Once set High, the Program Status bit can only be reset Low by a Clear Status Register command or a hardware reset. If set High it should be reset before a new command is issued, otherwise the new command will appear to fail. 7.5 VPP Status bit (SR3) The VPP Status bit can be used to identify an invalid voltage on the VPP pin during Program and Erase operations. The VPP pin is only sampled at the beginning of a Program or Erase operation. Indeterminate results can occur if VPP becomes invalid during an operation. When the VPP Status bit is Low (set to ‘0’), the voltage on the VPP pin was sampled at a valid voltage; when the VPP Status bit is High (set to ‘1’), the VPP pin has a voltage that is below the VPP Lockout Voltage, VPPLK, the memory is protected and Program and Erase operations cannot be performed. Once set High, the VPP Status bit can only be reset Low by a Clear Status Register command or a hardware reset. If set High it should be reset before a new Program or Erase command is issued, otherwise the new command will appear to fail. 39/123 Status Register 7.6 M58WRxxxKU, M58WRxxxKL Program Suspend Status bit (SR2) The Program Suspend Status bit indicates that a Program operation has been suspended in the addressed block. When the Program Suspend Status bit is High (set to ‘1’), a Program/Erase Suspend command has been issued and the memory is waiting for a Program/Erase Resume command. The Program Suspend Status should only be considered valid when the Program/Erase Controller Status bit is High (Program/Erase Controller inactive). SR2 is set within the Program Suspend Latency time of the Program/Erase Suspend command being issued therefore the memory may still complete the operation rather than entering the Suspend mode. When a Program/Erase Resume command is issued the Program Suspend Status bit returns Low. 7.7 Block Protection Status bit (SR1) The Block Protection Status bit can be used to identify if a Program or Block Erase operation has tried to modify the contents of a locked block. When the Block Protection Status bit is High (set to ‘1’), a Program or Erase operation has been attempted on a locked block. Once set High, the Block Protection Status bit can only be reset Low by a Clear Status Register command or a hardware reset. If set High it should be reset before a new command is issued, otherwise the new command will appear to fail. 7.8 Bank Write/Multiple Word Program Status bit (SR0) The Bank Write Status bit indicates whether the addressed bank is programming or erasing. In Enhanced Factory Program mode the Multiple Word Program bit shows if a word has finished programming or verifying depending on the phase. The Bank Write Status bit should only be considered valid when the Program/Erase Controller Status SR7 is Low (set to ‘0’). When both the Program/Erase Controller Status bit and the Bank Write Status bit are Low (set to ‘0’), the addressed bank is executing a Program or Erase operation. When the Program/Erase Controller Status bit is Low (set to ‘0’) and the Bank Write Status bit is High (set to ‘1’), a Program or Erase operation is being executed in a bank other than the one being addressed. In Enhanced Factory Program mode if Multiple Word Program Status bit is Low (set to ‘0’), the device is ready for the next word, if the Multiple Word Program Status bit is High (set to ‘1’) the device is not ready for the next word. Note: 40/123 Refer to Appendix C: Flowcharts and pseudocodes, for using the Status Register. M58WRxxxKU, M58WRxxxKL Table 10. Bit Status Register bits Name SR7 P/E.C. Status SR6 Erase Suspend Status SR5 Erase Status SR4 Program Status SR3 VPP Status Type Logic Level Definition (1) '1' Ready '0' Busy '1' Erase Suspended '0' Erase In progress or Completed '1' Erase Error '0' Erase Success '1' Program Error '0' Program Success '1' VPP Invalid, Abort '0' VPP OK '1' Program Suspended '0' Program In Progress or Completed '1' Program/Erase on protected Block, Abort '0' No operation to protected blocks Status Status Error Error Error Program Suspend Status Status SR1 Block Protection Status Error SR2 Status Register SR7 = ‘1’ Not Allowed '1' SR7 = ‘0’ Bank Write Status Status Program or erase operation in a bank other than the addressed bank SR7 = ‘1’ No Program or erase operation in the device '0' SR7 = ‘0’ Program or erase operation in addressed bank SR0 SR7 = ‘1’ Not Allowed Multiple Word Program Status (Enhanced Factory Program mode) '1' SR7 = ‘0’ the device is NOT ready for the next word Status SR7 = ‘1’ the device is exiting from EFP '0' SR7 = ‘0’ the device is ready for the next word 1. Logic level '1' is High, '0' is Low. 41/123 Configuration Register 8 M58WRxxxKU, M58WRxxxKL Configuration Register The Configuration Register is used to configure the type of bus access that the memory will perform. Refer to Read Modes section for details on read operations. The Configuration Register is set through the Command Interface. After a Reset or PowerUp the device is configured for asynchronous read (CR15 = 1). The Configuration Register bits are described in Table 12 They specify the selection of the burst length, burst type, burst X latency and the Read operation. Refer to Figures 7 and 8 for examples of synchronous burst configurations. 8.1 Read Select bit (CR15) The Read Select bit, CR15, is used to switch between asynchronous and synchronous Bus Read operations. When the Read Select bit is set to ’1’, read operations are asynchronous; when the Read Select bit is set to ’0’, read operations are synchronous. Synchronous Burst Read is supported in both parameter and main blocks and can be performed across banks. On reset or power-up the Read Select bit is set to’1’ for asynchronous access. 8.2 Bus Invert Configuration (CR14) The Bus Invert Configuration bit is used to enable the BINV functionality. When the functionality is enabled, if the BINV pin operates as an input pin (during write bus operations), the BINV signal must always be driven; if it operates as an output pin (during read bus operations), the functionality is valid only during synchronous read operations. 42/123 M58WRxxxKU, M58WRxxxKL 8.3 Configuration Register X-Latency bits (CR13-CR11) The X-Latency bits are used during Synchronous Read operations to set the number of clock cycles between the address being latched and the first data becoming available. Refer to Figure 7: X-latency and data output configuration example. For correct operation the X-Latency bits can only assume the values in Table 12: Configuration Register. Table 11 shows how to set the X-Latency parameter, taking into account the speed class of the device and the Frequency used to read the Flash memory in Synchronous mode. Table 11. 8.4 X-latency settings fmax tKmin X-Latency min 30 MHz 33 ns 2 40 MHz 25 ns 3 54 MHz 19 ns 4 66 MHz 15 ns 4 86 MHz 12 ns 5 Wait Polarity bit (CR10) In synchronous burst mode the Wait signal indicates whether the output data are valid or a WAIT state must be inserted. The Wait Polarity bit is used to set the polarity of the Wait signal. When the Wait Polarity bit is set to ‘0’ the Wait signal is active Low. When the Wait Polarity bit is set to ‘1’ the Wait signal is active High. 8.5 Data Output Configuration bit (CR9) The Data Output Configuration bit determines whether the output remains valid for one or two clock cycles. When the Data Output Configuration bit is ’0’ the output data is valid for one clock cycle, when the Data Output Configuration bit is ’1’ the output data is valid for two clock cycles. The Data Output Configuration depends on the condition: ● tK > tKQV + tQVK_CPU where tK is the clock period, tQVK_CPU is the data setup time required by the system CPU and tKQV is the clock to data valid time. If this condition is not satisfied, the Data Output Configuration bit should be set to ‘1’ (two clock cycles). Refer to Figure 7: X-latency and data output configuration example. 8.6 Wait Configuration bit (CR8) In burst mode the Wait bit controls the timing of the Wait output pin, WAIT. When WAIT is asserted, Data is Not Valid and when WAIT is deasserted, Data is Valid. When the Wait bit is ’0’ the Wait output pin is asserted during the wait state. When the Wait bit is ’1’ the Wait output pin is asserted one clock cycle before the wait state. 43/123 Configuration Register 8.7 M58WRxxxKU, M58WRxxxKL Burst Type bit (CR7) The Burst Type bit is used to configure the sequence of addresses read as sequential or interleaved. When the Burst Type bit is ’0’ the memory outputs from interleaved addresses; when the Burst Type bit is ’1’ the memory outputs from sequential addresses. See Table 13: Burst type definition, for the sequence of addresses output from a given starting address in each mode. 8.8 Valid Clock Edge bit (CR6) The Valid Clock Edge bit, CR6, is used to configure the active edge of the Clock, K, during Synchronous Burst Read operations. When the Valid Clock Edge bit is ’0’ the falling edge of the Clock is the active edge; when the Valid Clock Edge bit is ’1’ the rising edge of the Clock is active. 8.9 Power-Down bit (CR5) The Power-Down bit is used to enable or disable the Power-Down function. When it is set to ‘0’ the Power-Down function is disabled. If the Reset/Power-Down, RP, pin goes Low (VIL), the device is reset and the supply current IDD is reduced to the Standby value IDD3. When the Power-Down bit is set to ‘1’ the Power-Down function is enabled. If the Reset/PowerDown, RP, pin goes Low (VIL) the device switches to the Power-Down state and the supply current IDD is reduced to the Reset/Power-Down value, IDD2. The recovery time after a Reset/Power-Down, RP, pulse is significantly longer when PowerDown is enabled (see Table 28: Reset and Power-up ac characteristics). 8.10 Wrap Burst bit (CR3) The burst reads can be confined inside the 4, 8 or 16 word boundary (wrap) or overcome the boundary (no wrap). The Wrap Burst bit is used to select between wrap and no wrap. When the Wrap Burst bit is set to ‘0’ the burst read wraps; when it is set to ‘1’ the burst read does not wrap. 44/123 M58WRxxxKU, M58WRxxxKL 8.11 Configuration Register Burst length bits (CR2-CR0) The Burst Length bits set the number of words to be output during a Synchronous Burst Read operation as result of a single address latch cycle. They can be set for 4 words, 8 words, 16 words or continuous burst, where all the words are read sequentially. In continuous burst mode the burst sequence can cross bank boundaries. In continuous burst mode or in 4, 8, 16 words no-wrap, depending on the starting address, the device asserts the WAIT output to indicate that a delay is necessary before the data is output. If the starting address is aligned to a 4 word boundary no wait states are needed and the WAIT output is not asserted. If the starting address is shifted by 1, 2 or 3 positions from the four word boundary, WAIT will be asserted for 1, 2 or 3 clock cycles when the burst sequence crosses the first 16 word boundary, to indicate that the device needs an internal delay to read the successive words in the array. WAIT will be asserted only once during a continuous burst access. See also Table 13: Burst type definition. CR4 is reserved for future use. 45/123 Configuration Register Table 12. M58WRxxxKU, M58WRxxxKL Configuration Register Bit CR15 CR14 CR13-CR11 Description Value Description 0 Synchronous Read 1 Asynchronous Read (Default at power-on) 0 BINV (power save) disabled (default) 1 BINV (power save) enabled 010 2 clock latency 011 3 clock latency 100 4 clock latency 101 5 clock latency 111 Reserved (default) Read Select Bus invert configuration X-Latency Other configurations reserved CR10 CR9 CR8 CR7 CR6 CR5 46/123 Data Output Configuration WAIT is active Low (default) 1 WAIT is active High 0 Data held for one clock cycle 1 Data held for two clock cycles (default) 0 WAIT is active during wait state (default) 1 WAIT is active one data cycle before wait state 0 Interleaved 1 Sequential (default) 0 Falling Clock edge 1 Rising Clock edge (default) 0 Power-Down disabled (default) 1 Power-Down enabled 0 Wrap 1 No Wrap (default) 001 4 words 010 8 words 011 16 words 111 Continuous (CR7 must be set to ‘1’) (default) Wait Configuration Burst Type Valid Clock Edge Power-Down Configuration CR4 Reserved CR3 Wrap Burst CR2-CR0 0 Wait Polarity Burst Length M58WRxxxKU, M58WRxxxKL Mode Table 13. Burst type definition 4 words Start Add Configuration Register Sequential 8 words InterSequential Interleaved leaved 16 words Sequential Interleaved Continuous Burst 0 0-1-2-3 0-1-2-3 0-1-2-3-45-6-7 0-1-2-3-4-5-6-7-80-1-2-3-4-59-10-11-12-13-146-7 15 0-1-2-3-4-5-67-8-9-10-1112-13-14-15 0-1-2-3-4-5-6... 1 1-2-3-0 1-0-3-2 1-2-3-4-56-7-0 1-0-3-2-5-47-6 1-2-3-4-5-6-7-8-910-11-12-13-1415-0 1-0-3-2-5-4-76-9-8-11-1013-12-15-14 1-2-3-4-5-6-7...15-WAIT-1617-18... 2 2-3-0-1 2-3-0-1 2-3-4-5-67-0-1 2-3-0-1-6-74-5 2-3-4-5-6-7-8-910-11-12-13-1415-0-1 3-2-1-0 3-4-5-6-70-1-2 3-4-5-6-7-8-9-103-2-1-0-7-611-12-13-14-15-05-4 1-2 7-6-5-4 7-0-1-2-34-5-6 7-8-9-10-11-12-13- 7-6-5-4-3-2-17-6-5-4-3-214-15-0-1-2-3-4-5- 0-15-14-131-0 6 12-11-10-9-8 3 3-0-1-2 2-3-0-1-6-7-4- 2-3-4-5-6-7...155-10-11-8-9WAIT-WAIT-1614-15-12-13 17-18... 3-2-1-0-7-6-54-11-10-9-815-14-13-12 3-4-5-6-7...15WAIT-WAITWAIT-16-1718... Wrap ... 7 7-4-5-6 7-8-9-10-11-1213-14-15-WAITWAIT-WAIT-1617... ... 12 12-13-14-15-1617-18... 13 13-14-15-WAIT16-17-18... 14 14-15-WAITWAIT-16-1718.... 15 15-WAIT-WAITWAIT-16-1718... 47/123 Configuration Register Mode Table 13. Burst type definition (continued) 4 words Start Add M58WRxxxKU, M58WRxxxKL Sequential 8 words InterSequential Interleaved leaved 16 words Sequential 0 0-1-2-3 0-1-2-3-45-6-7 0-1-2-3-4-5-6-7-89-10-11-12-13-1415 1 1-2-3-4 1-2-3-4-56-7-8 1-2-3-4-5-6-7-8-910-11-12-13-1415-WAIT-16 2-3-4-5 2-3-4-5-67-8-9... 2-3-4-5-6-7-8-910-11-12-13-1415-WAIT-WAIT-1617 3-4-5-6 3-4-5-6-78-9-10 3-4-5-6-7-8-9-1011-12-13-14-15WAIT-WAIT-WAIT16-17-18 7-8-9-10 7-8-9-1011-12-1314 7-8-9-10-11-12-1314-15-WAIT-WAITWAIT-16-17-18-1920-21-22 12 12-13-1415 12-13-1415-16-1718-19 12-13-14-15-1617-18-19-20-2122-23-24-25-26-27 13 13-14-15WAIT-16 13-14-15WAIT-1617-18-1920 13-14-15-WAIT-1617-18-19-20-2122-23-24-25-2627-28 14 14-15WAITWAIT-1617 14-15WAITWAIT-1617-18-1920-21 14-15-WAIT-WAIT16-17-18-19-2021-22-23-24-2526-27-28-29 15 15-WAITWAITWAIT-1617-18 15-WAITWAITWAIT-1617-18-1920-21-22 15-WAIT-WAITWAIT-16-17-18-1920-21-22-23-2425-26-27-28-29-30 2 3 Interleaved Continuous Burst No-wrap ... 48/123 7 ... Same as for Wrap (Wrap /No Wrap has no effect on Continuous Burst) M58WRxxxKU, M58WRxxxKL Figure 7. Configuration Register X-latency and data output configuration example X-latency 1st cycle 2nd cycle 3rd cycle 4th cycle K E L A16-Amax(1) VALID ADDRESS tQVK_CPU tK tKQV ADQ15-ADQ0 VALID ADDRESS VALID DATA VALID DATA AI13522 1. Amax is equal to A19 in the M58WR016KU/L, to A20 in the M58WR032KU/L, and to A21 in the M58WR064KU/L. 2. Settings shown: X-latency = 4, Data Output held for one clock cycle. 49/123 Configuration Register Figure 8. M58WRxxxKU, M58WRxxxKL Wait configuration example E K L G A16-Amax(1) VALID ADDRESS ADQ15-ADQ0 VALID ADDRESS VALID DATA VALID DATA NOT VALID VALID DATA WAIT CR8 = '0' CR10 = '0' WAIT CR8 = '1' CR10 = '0' WAIT CR8 = '0' CR10 = '1' WAIT CR8 = '1' CR10 = '1' AI13523 1. Amax is equal to A19 in the M58WR016KU/L, to A20 in the M58WR032KU/L, and to A21 in the M58WR064KU/L. 50/123 M58WRxxxKU, M58WRxxxKL 9 Read modes Read modes Read operations can be performed in two different ways depending on the settings in the Configuration Register. If the clock signal is ‘don’t care’ for the data output, the read operation is Asynchronous; if the data output is synchronized with clock, the read operation is Synchronous. The Read mode and data output format are determined by the Configuration Register. (See Configuration Register section for details). All banks supports both asynchronous and synchronous read operations. The Multiple Bank architecture allows read operations in one bank, while write operations are being executed in another (see Tables 14 and 15). 9.1 Asynchronous Read mode In Asynchronous Read operations the clock signal is ‘don’t care’. The device outputs the data corresponding to the address latched, that is the memory array, Status Register, Common Flash Interface or Electronic Signature depending on the command issued. CR15 in the Configuration Register must be set to ‘1’ for Asynchronous operations. In Asynchronous Read mode, the WAIT signal is always deasserted. The device features an Automatic Standby mode. During asynchronous read operations, after a bus inactivity of 150 ns, the device automatically switches to the Automatic Standby mode. In this condition the power consumption is reduced to the standby value IDD4 and the outputs are still driven. See Table 24: Asynchronous Read ac characteristics, and Figure 11: Asynchronous random access read ac waveforms. 51/123 Read modes 9.2 M58WRxxxKU, M58WRxxxKL Synchronous Burst Read mode In Synchronous Burst Read mode the data is output in bursts synchronized with the clock. It is possible to perform burst reads across bank boundaries. Synchronous Burst Read mode can only be used to read the memory array. For other read operations, such as Read Status Register, Read CFI and Read Electronic Signature, Single Synchronous Read or Asynchronous Random Access Read must be used. In Synchronous Burst Read mode the flow of the data output depends on parameters that are configured in the Configuration Register. A burst sequence is started at the first clock edge (rising or falling depending on Valid Clock Edge bit CR6 in the Configuration Register) after the falling edge of Latch Enable. Addresses are internally incremented and after a delay of 2 to 5 clock cycles (X latency bits CR13-CR11) the corresponding data are output on each clock cycle. The number of words to be output during a Synchronous Burst Read operation can be configured as 4, 8 or 16 words or Continuous (Burst Length bits CR2-CR0). The data can be configured to remain valid for one or two clock cycles (Data Output Configuration bit CR9). The order of the data output can be modified through the Burst Type and the Wrap Burst bits in the Configuration Register. The burst sequence may be configured to be sequential or interleaved (CR7). The burst reads can be confined inside the 4, 8 or 16 word boundary (Wrap) or overcome the boundary (No Wrap). If the starting address is aligned to the Burst Length (4, 8 or 16 words), the wrapped configuration has no impact on the output sequence. Interleaved mode is not allowed in Continuous Burst Read mode or with No Wrap sequences. A WAIT signal may be asserted to indicate to the system that an output delay will occur. This delay will depend on the starting address of the burst sequence; the worst case delay will occur when the sequence is crossing a 16 word boundary and the starting address was at the end of a four word boundary. WAIT is asserted during X-latency, the Wait state and at the end of a 4, 8 and 16 word burst. It is only deasserted when output data are valid or when G is at VIH. In Continuous Burst Read mode a Wait state will occur when crossing the first 16 word boundary. If the burst starting address is aligned to a 4 word Page, the Wait state will not occur. The WAIT signal can be configured to be active Low or active High by setting CR10 in the Configuration Register. See Table 25: Synchronous Read ac characteristics, and Figure 12: Synchronous Burst Read ac waveforms, for details. 52/123 M58WRxxxKU, M58WRxxxKL 9.2.1 Read modes Synchronous Burst Read Suspend A Synchronous Burst Read operation can be suspended, freeing the data bus for other higher priority devices. It can be suspended during the initial access latency time (before data is output) or after the device has output data. When the Synchronous Burst Read operation is suspended, internal array sensing continues and any previously latched internal data is retained. A burst sequence can be suspended and resumed as often as required as long as the operating conditions of the device are met. A Synchronous Burst Read operation is suspended when E is low and the current address has been latched (on a Latch Enable rising edge or on a valid clock edge). The clock signal is then halted at VIH or at VIL, and G goes high. When G becomes low again and the clock signal restarts, the Synchronous Burst Read operation is resumed exactly where it stopped. WAIT being gated by E remains active and will not revert to high-impedance when G goes high. So if two or more devices are connected to the system’s READY signal, to prevent bus contention the WAIT signal of the Flash memory should not be directly connected to the system’s READY signal. See Table 25: Synchronous Read ac characteristics, and Figure 14: Synchronous Burst Read Suspend ac waveforms for details. 9.3 Single Synchronous Read mode Single Synchronous Read operations are similar to Synchronous Burst Read operations except that only the first data output after the X latency is valid. Synchronous Single Reads are used to read the Electronic Signature, Status Register, CFI, Block Protection Status, Configuration Register Status or Protection Register. When the addressed bank is in Read CFI, Read Status Register or Read Electronic Signature mode, the WAIT signal is deasserted when Output Enable, G, is at VIH or for the one clock cycle during which output data is valid. Otherwise, it is asserted. See Table 25: Synchronous Read ac characteristics and Figure 13: Single Synchronous Read ac waveforms, for details. 53/123 Dual operations and multiple bank architecture 10 M58WRxxxKU, M58WRxxxKL Dual operations and multiple bank architecture The Multiple Bank Architecture of the M58WRxxxKU/L provides flexibility for software developers by allowing code and data to be split with 4 Mbit granularity. The Dual Operations feature simplifies the software management of the device and allows code to be executed from one bank while another bank is being programmed or erased. The Dual operations feature means that while programming or erasing in one bank, Read operations are possible in another bank with zero latency (only one bank at a time is allowed to be in Program or Erase mode). If a Read operation is required in a bank which is programming or erasing, the Program or Erase operation can be suspended. Also if the suspended operation was Erase then a Program command can be issued to another block, so the device can have one block in Erase Suspend mode, one programming and other banks in Read mode. Bus Read operations are allowed in another bank between setup and confirm cycles of program or erase operations. The combination of these features means that read operations are possible at any moment. Dual operations between the Parameter Bank and either of the CFI, the OTP or the Electronic Signature memory space are not allowed. Table 16 shows which dual operations are allowed or not between the CFI, the OTP, the Electronic Signature locations and the memory array. Tables 14 and 15 show the dual operations possible in other banks and in the same bank. Note that only the commonly used commands are represented in these tables. For a complete list of possible commands refer to Appendix D: Command interface state tables. Table 14. Dual operations allowed in other banks Commands allowed in another bank Status of bank 54/123 Read Array Read Status Register Read CFI Query Read Program/ Program/ Electronic Program Erase Erase Erase Signature Suspend Resume Idle Yes Yes Yes Yes Yes Yes Yes Yes Programming Yes Yes Yes Yes – – Yes – Erasing Yes Yes Yes Yes – – Yes – Program Suspended Yes Yes Yes Yes – – – Yes Erase Suspended Yes Yes Yes Yes Yes – – Yes M58WRxxxKU, M58WRxxxKL Table 15. Dual operations and multiple bank architecture Dual operations allowed in same bank Commands allowed in same bank Status of bank Idle Programming Erasing Read Array Read Status Register Read CFI Query Yes Yes Yes Yes Yes Yes Yes Yes (1)) Yes Yes Yes – – Yes – (1) Yes Yes Yes – – Yes – – – Read Electronic Program Signature Erase Program/ Program/ Erase Erase Suspend Resume Program Suspended Yes(2) Yes Yes Yes – – – Yes Erase Suspended Yes(2) Yes Yes Yes Yes(2) – – Yes 1. The Read Array command is accepted but the data output is not guaranteed until the Program or Erase has completed. 2. Not allowed in the Block or word that is being erased or programmed. Table 16. Dual operation limitations Commands allowed Read Main Blocks Read CFI / OTP / Electronic Signature Read Parameter Blocks No Located in Parameter Bank Not Located in Parameter Bank Current Status Programming / Erasing Parameter Blocks Programming / Erasing Main Blocks Programming OTP Located in Parameter Bank Not Located in Parameter Bank No No Yes Yes No No Yes Yes Yes Yes In Different Bank Only No No No No 55/123 Block locking 11 M58WRxxxKU, M58WRxxxKL Block locking The M58WRxxxKU/L features an instant, individual block locking scheme that allows any block to be locked or unlocked with no latency. This locking scheme has three levels of protection. ● Lock/Unlock - this first level allows software-only control of block locking. ● Lock-Down - this second level requires hardware interaction before locking can be changed. ● VPP ≤VPPLK - the third level offers a complete hardware protection against program and erase on all blocks. The protection status of each block can be set to Locked, Unlocked, and Lock-Down. Table 17, defines all of the possible protection states (WP, DQ1, DQ0), and Appendix C: Flowcharts and pseudocodes, Figure 26, shows a flowchart for the locking operations. 11.1 Reading a block’s lock status The lock status of every block can be read in the Read Electronic Signature mode of the device. To enter this mode write 90h to the device. Subsequent reads at the address specified in Table 8, will output the protection status of that block. The lock status is represented by DQ0 and DQ1. DQ0 indicates the Block Lock/Unlock status and is set by the Lock command and cleared by the Unlock command. It is also automatically set when entering Lock-Down. DQ1 indicates the Lock-Down status and is set by the Lock-Down command. It cannot be cleared by software, only by a hardware reset or power-down. The following sections explain the operation of the locking system. 11.2 Locked state The default status of all blocks on power-up or after a hardware reset is Locked (states (0,0,1) or (1,0,1)). Locked blocks are fully protected from any program or erase. Any program or erase operations attempted on a locked block will return an error in the Status Register. The Status of a Locked block can be changed to Unlocked or Lock-Down using the appropriate software commands. An Unlocked block can be Locked by issuing the Lock command. 11.3 Unlocked state Unlocked blocks (states (0,0,0), (1,0,0) (1,1,0)), can be programmed or erased. All unlocked blocks return to the Locked state after a hardware reset or when the device is powereddown. The status of an unlocked block can be changed to Locked or Locked-Down using the appropriate software commands. A locked block can be unlocked by issuing the Unlock command. 56/123 M58WRxxxKU, M58WRxxxKL 11.4 Block locking Lock-Down state Blocks that are Locked-Down (state (0,1,x))are protected from program and erase operations (as for Locked blocks) but their protection status cannot be changed using software commands alone. A Locked or Unlocked block can be Locked-Down by issuing the Lock-Down command. Locked-Down blocks revert to the Locked state when the device is reset or powered-down. The Lock-Down function is dependent on the WP input pin. When WP=0 (VIL), the blocks in the Lock-Down state (0,1,x) are protected from program, erase and protection status changes. When WP=1 (VIH) the Lock-Down function is disabled (1,1,x) and Locked-Down blocks can be individually unlocked to the (1,1,0) state by issuing the software command, where they can be erased and programmed. These blocks can then be re-locked (1,1,1) and unlocked (1,1,0) as desired while WP remains high. When WP is Low, blocks that were previously Locked-Down return to the Lock-Down state (0,1,x) regardless of any changes made while WP was high. Device reset or power-down resets all blocks, including those in Lock-Down, to the Locked state. 11.5 Locking operations during Erase Suspend Changes to block lock status can be performed during an erase suspend by using the standard locking command sequences to unlock, lock or lock-down a block. This is useful in the case when another block needs to be updated while an erase operation is in progress. To change block locking during an erase operation, first write the Erase Suspend command, then check the status register until it indicates that the erase operation has been suspended. Next write the desired Lock command sequence to a block and the lock status will be changed. After completing any desired lock, read, or program operations, resume the erase operation with the Erase Resume command. If a block is locked or locked-down during an erase suspend of the same block, the locking status bits will be changed immediately, but when the erase is resumed, the erase operation will complete. Locking operations cannot be performed during a program suspend. Refer to Appendix D: Command interface state tables, for detailed information on which commands are valid during erase suspend. 57/123 Block locking M58WRxxxKU, M58WRxxxKL Table 17. Lock status Current Protection Status(1) (WP, ADQ1, ADQ0) Current State 1,0,0 Next Protection status(1) (WP, ADQ1, ADQ0) Program/Erase After Block Lock Allowed Command After Block Unlock Command After Block Lock-Down Command After WP transition yes 1,0,1 1,0,0 1,1,1 0,0,0 no 1,0,1 1,0,0 1,1,1 0,0,1 1,1,0 yes 1,1,1 1,1,0 1,1,1 0,1,1 1,1,1 no 1,1,1 1,1,0 1,1,1 0,1,1 0,0,0 yes 0,0,1 0,0,0 0,1,1 1,0,0 no 0,0,1 0,0,0 0,1,1 1,0,1 no 0,1,1 0,1,1 0,1,1 1,1,1 or 1,1,0(3) 1,0,1 0,0,1 (2) (2) 0,1,1 1. The lock status is defined by the write protect pin and by DQ1 (‘1’ for a locked-down block) and DQ0 (‘1’ for a locked block) as read in the Read Electronic Signature command with A1 = VIH and A0 = VIL. 2. All blocks are locked at power-up, so the default configuration is 001 or 101 according to WP status. 3. A WP transition to VIH on a locked block will restore the previous DQ0 value, giving a 111 or 110. 58/123 M58WRxxxKU, M58WRxxxKL 12 Program and erase times and endurance cycles Program and erase times and endurance cycles The Program and Erase times and the number of Program/ Erase cycles per block are shown in Table 18 In the M58WRxxxKU/L the maximum number of Program/ Erase cycles depends on the voltage supply used. Program, erase times and endurance cycles(1) Table 18. Parameter VPP = VDD Erase Program(3) Suspend Latency Condition Typical after 100k Max W/E Cycles Unit 0.3 1 2.5 s Main Block (32 Preprogrammed Kword) Not Preprogrammed 0.8 3 4 s 4 s Word 12 100 µs Parameter Block (4 Kword) 40 ms Main Block (32 Kword) 300 ms 1 12 Program 5 10 µs Erase 5 20 µs Parameter Block (4 Kword) Main Block (32 Kword) Word/ Double Word/ Quadruple Word(4) Quad-Enhanced Factory (3) Program cycles 100,000 cycles 0.25 2.5 s 0.8 4 s 10 100 µs ms 45 ms 10 ms Word 40 ms Quad-Enhanced Factory 94 ms 360 ms 80 ms 328 ms 0.75 s 0.65 s Main Block (32 Enhanced Factory Kword) Quadruple Word(4) Word Bank (4Mbit) 100,000 11 Enhanced Factory Parameter Block (4 Kword) Quadruple Word(4) VPP = VPPH Typ Parameter Block (4 Kword)(2) Main Blocks Program/Erase Cycles (per Block) Parameter Blocks Erase Min Quad-Enhanced Quadruple Factory(4) Word(4) Main Blocks Program/Erase Cycles (per Block) Parameter Blocks 1000 cycles 2500 cycles 1. TA = –40 to 85°C; VDD = VDDQ = 1.7 V to 2 V. 2. The difference between preprogrammed and not preprogrammed is not significant (‹30 ms). 3. Values are liable to change with the external system-level overhead (command sequence and Status Register polling execution). 4. Measurements performed at 25°C. TA = 30°C ±10°C for Quadruple Word, Double Word and Quadruple Enhanced Factory Program. 59/123 Maximum rating 13 M58WRxxxKU, M58WRxxxKL Maximum rating Stressing the device above the rating listed in the Absolute Maximum Ratings table may cause permanent damage to the device. These are stress ratings only and operation of the device at these or any other conditions above those indicated in the Operating sections of this specification is not implied. Exposure to Absolute Maximum Rating conditions for extended periods may affect device reliability. Refer also to the Numonyx SURE Program and other relevant quality documents. Table 19. Absolute maximum ratings Value Symbol Unit Min Max Ambient operating temperature –40 85 °C TBIAS Temperature under bias –40 125 °C TSTG Storage temperature –65 155 °C VIO Input or output voltage –0.5 VDDQ+0.6 V VDD Supply voltage –0.2 2.45 V Input/output supply voltage –0.2 2.45 V Program voltage –0.2 10.0 V Output short circuit current 100 mA Time for VPP at VPPH 100 hours TA VDDQ VPP IO tVPPH 60/123 Parameter M58WRxxxKU, M58WRxxxKL 14 DC and AC parameters DC and AC parameters This section summarizes the operating measurement conditions, and the DC and AC characteristics of the device. The parameters in the DC and AC characteristics Tables that follow, are derived from tests performed under the Measurement Conditions summarized in Table 20: Operating and ac measurement conditions. Designers should check that the operating conditions in their circuit match the operating conditions when relying on the quoted parameters. Table 20. Operating and ac measurement conditions M58WRxxxKU/L Parameter 60 ns 70 ns Unit Min Max Min Max VDD supply voltage 1.7 2 1.7 2 V VDDQ supply voltage 1.7 2 1.7 2 V VPP supply voltage (factory environment) 8.5 9.5 8.5 9.5 V VPP supply voltage (application environment) –0.4 VDDQ+0.4 –0.4 VDDQ+0.4 V Ambient operating temperature –40 85 –40 85 °C Load capacitance (CL) 30 Input rise and fall times 5 Input pulse voltages Input and output timing ref. voltages Figure 9. 30 pF 5 ns 0 to VDDQ 0 to VDDQ V VDDQ/2 VDDQ/2 V AC measurement I/O waveform VDDQ VDDQ/2 0V AI06161 61/123 DC and AC parameters M58WRxxxKU, M58WRxxxKL Figure 10. AC measurement load circuit VDDQ VDDQ VDD 16.7kΩ DEVICE UNDER TEST CL 0.1µF 16.7kΩ 0.1µF CL includes JIG capacitance Table 21. Symbol CIN COUT Capacitance(1) Parameter Input capacitance Output capacitance 1. Sampled only, not 100% tested. 62/123 AI06162 Test condition Min Max Unit VIN = 0 V 6 8 pF VOUT = 0 V 8 12 pF M58WRxxxKU, M58WRxxxKL Table 22. Symbol DC and AC parameters DC characteristics - currents Parameter Test condition ILI Input leakage current ILO Max Unit 0V ≤VIN ≤VDDQ ±1 µA Output leakage current 0V ≤VOUT ≤VDDQ ±1 µA Supply current Asynchronous Read (f=6 MHz) E = VIL, G = VIH 10 20 mA 4 word 18 20 mA 8 word 20 22 mA 16 word 22 24 mA Continuous 24 26 mA 4 word 22 25 mA 8 word 25 27 mA 16 word 30 32 mA Continuous 33 35 mA Supply current Synchronous Read (f=66 MHz) IDD1 Supply current Synchronous Read (f=86 MHz) Min Typ IDD2 Supply current (Reset/Power-Down) RP = VSS ± 0.2 V 2 10 µA IDD3 Supply current (Standby) E = VDDQ ± 0.2 V, K = VSS 15 50 µA IDD4 Supply current (Automatic Standby) E = VIL, G = VIH 15 50 µA VPP = VPPH 10 30 mA VPP = VDD 20 34 mA VPP = VPPH 10 30 mA VPP = VDD 20 34 mA Program/Erase in one Bank, Asynchronous Read in another Bank 30 54 mA Program/Erase in one Bank, Synchronous Read (continuous burst 66 MHz) in another Bank 44 60 mA E = VDDQ ± 0.2 V, K = VSS 15 50 µA VPP = VPPH 5 10 mA VPP = VDD 0.2 5 µA VPP = VPPH 5 10 mA VPP = VDD 0.2 5 µA VPP = VPPH 100 400 µA VPP ≤VDD 0.2 5 µA VPP ≤VDD 0.2 5 µA Supply current (Program) IDD5(1) Supply current (Erase) IDD6(1)(2) IDD7(1) Supply current (Dual operations) Supply current Program/ Erase Suspended (Standby) VPP supply current (Program) IPP1(1) VPP supply current (Erase) IPP2 IPP3(1) VPP supply current (Read) VPP supply current (Standby) 1. Sampled only, not 100% tested. 2. VDD Dual operation current is the sum of read and program or erase currents. 63/123 DC and AC parameters Table 23. Symbol DC characteristics - voltages Parameter Test condition Min Typ Max Unit VIL Input low voltage –0.5 0.4 V VIH Input high voltage VDDQ –0.4 VDDQ + 0.4 V VOL Output low voltage IOL = 100 µA 0.1 V VOH Output high voltage IOH = –100 µA VDDQ –0.1 VPP1 VPP program voltage-logic Program, Erase 1.3 Program, Erase 8.5 VPPH 64/123 M58WRxxxKU, M58WRxxxKL VPP program voltage factory VPPLK Program or Erase lockout VLKO VDD lock voltage V 9 2.4 V 9.5 V 0.4 V 1 V Hi-Z tELTV tELQV tLLQV Valid Address Latch tELLH tLLLH Outputs Enabled tGLQX tGLQV tLHGL tLHAX Data Valid tAVAV VALID DATA tEHTZ tGHQZ tGHQX tEHQX tEHQZ Standby Notes: 1- WAIT is active Low. 2- Amax is equal to A19 in the M58WR016KU/L, to A20 in the M58WR032KU/L, and to A21 in the M58WR064KU/L. WAIT(2) G E L VALID ADDRESS A16-Amax(1) tAVLH VALID ADDRESS ADQ0-ADQ15 tAVQV AI13524 VALID Hi-Z M58WRxxxKU, M58WRxxxKL DC and AC parameters Figure 11. Asynchronous random access read ac waveforms 65/123 DC and AC parameters Table 24. M58WRxxxKU, M58WRxxxKL Asynchronous Read ac characteristics M58WRxxxKU/L Symbol Alt 70 tRC Address Valid to Next Address Valid Min 60 70 ns tAVQV tACC Address Valid to Output Valid (Random) Max 60 70 ns Chip Enable Low to Wait Valid Max 9 11 ns Chip Enable Low to Output Valid Max 60 70 ns Chip Enable High to Wait Hi-Z Max 11 14 ns tELQV(1) Read Timings Unit 60 tAVAV tELTV Latch Timings Parameter tCE tEHTZ tEHQX(2) tOH Chip Enable High to Output Transition Min 0 0 ns (2) tHZ Chip Enable High to Output Hi-Z Max 11 14 ns tGLQV(1) tOE Output Enable Low to Output Valid Max 20 20 ns tGLQX(2) tOLZ Output Enable Low to Output Transition Min 0 0 ns tGHQX(2) tOH Output Enable High to Output Transition Min 0 0 ns tGHQZ(2) tDF Output Enable High to Output Hi-Z Max 11 14 ns tAVLH tAVADVH Address Valid to Latch Enable High Min 4 7 ns tELLH tELADVH Chip Enable Low to Latch Enable High Min 9 10 ns tLHAX tADVHAX Latch Enable High to Address Transition Min 4 7 ns Min 7 7 ns tEHQZ tLLLH tADVLADVH Latch Enable Pulse Width tLLQV tADVLQV Latch Enable Low to Output Valid (Random) Max 60 70 ns tLHGL tADVHGL Latch Enable High to Output Enable Low Min 4 5 ns 1. G may be delayed by up to tELQV - tGLQV after the falling edge of E without increasing tELQV. 2. Sampled only, not 100% tested. 66/123 Hi-Z tELKH tLLLH Address Latch tELTV tKHAX tAVKH tLLKH tAVLH VALID ADDRESS X Latency tGLTV tGLQX Note 2 tKHTV tGLQV Note 1 tKHQV Valid Data Flow Note 2 tKHTX tKHQX VALID VALID Boundary Crossing Note 2 NOT VALID NOT VALID Note 1. The number of clock cycles to be inserted depends on the X latency set in the Configuration Register. 2. The WAIT signal can be configured to be active during wait state or one cycle before. WAIT signal is active Low. 3. Address latched and data output on the rising clock edge. 4. The BINV signal has the waveform shown only if it has been enabled with the Configuration Register. If it is disabled, it remains low. 5. Amax is equal to A19 in the M58WR016KU/L, to A20 in the M58WR032KU/L, and to A21 in the M58WR064KU/L. WAIT G E K L A16-Amax(5) VALID VALID ADQ0-ADQ15 VALID ADDRESS VALID BINV(4) Data Valid tGHQZ tGHQX AI13525 Standby tEHTZ tEHQZ tEHQX tEHEL VALID VALID M58WRxxxKU, M58WRxxxKL DC and AC parameters Figure 12. Synchronous Burst Read ac waveforms 67/123 68/123 tELKH Hi-Z tELTV tKHAX tAVKH tLLKH tLLLH tGLTV tGLQV tGLQX Note 1 tKHTV tKHQV VALID NOT VALID NOT VALID NOT VALID NOT VALID NOT VALID NOT VALID Note 1. The number of clock cycles to be inserted depends on the X latency set in the Configuration Register. 2. The WAIT signal is configured to be active during wait state. WAIT signal is active Low. 3. Address latched and data output on the rising clock edge. 4. The BINV signal has the shown waveform only if it has been enabled with the Configuration Register. When disabled, it remains Low. 5. Amax is equal to A19 in the M58WR016KU/L, to A20 in the M58WR032KU/L, and to A21 in the M58WR064KU/L. WAIT(2) G E K(3) L VALID ADDRESS A16-Amax(5) tAVLH VALID ADDRESS ADQ0-ADQ15 BINV(4) tGHTV NOT VALID NOT VALID tGHQZ tGHQX tEHEL tEHQZ tEHQX NOT VALID NOT VALID AI13526 tEHTZ DC and AC parameters M58WRxxxKU, M58WRxxxKL Figure 13. Single Synchronous Read ac waveforms tELKH Hi-Z tELTV tKHAX tAVKH tLLKH tGLQV tGLTV tGLQX Note 1 tKHQV VALID VALID VALID tGHQZ Note 3 Note 1. The number of clock cycles to be inserted depends on the X latency set in the Configuration Register. 2. The WAIT signal is configured to be active during wait state. WAIT signal is active Low. 3. The CLOCK signal can be held high or low 4. Address latched and data output on the rising clock edge. 5. The BINV signal has the shown waveform only if it has been enabled with the Configuration Register. When disabled, it remains Low. 6. Amax is equal to A19 in the M58WR016KU/L, to A20 in the M58WR032KU/L, and to A21 in the M58WR064KU/L. WAIT(2) G E K(4) L tLLLH VALID ADDRESS A16-Amax(6) tAVLH VALID ADDRESS ADQ0-ADQ15 BINV(5) VALID VALID tEHEL tEHQZ tEHQX VALID VALID AI13527 tEHTZ tGHQX M58WRxxxKU, M58WRxxxKL DC and AC parameters Figure 14. Synchronous Burst Read Suspend ac waveforms 69/123 DC and AC parameters M58WRxxxKU, M58WRxxxKL Figure 15. Clock input ac waveform tKHKL tKHKH tr tf tKLKH AI06981 Table 25. Synchronous Read ac characteristics M58WRxxxKU/L Synchronous Read Timings Symbol Parameter Unit 60 70 tAVKH tAVCLKH Address Valid to Clock High Min 4 5 ns tELKH tELCLKH Chip Enable Low to Clock High Min 4 5 ns tELTV Chip Enable Low to Wait Valid Max 9 11 ns tEHEL Chip Enable Pulse Width (subsequent synchronous reads) Min 11 14 ns tEHTZ Chip Enable High to Wait Hi-Z Max 11 14 ns tGHTV Output Enable High to Wait Valid Min 11 11 ns tGLTV Output Enable Low to Wait Valid Max 11 11 ns tKHAX tCLKHAX Clock High to Address Transition Min 6 7 ns tKHQV tKHTV tCLKHQV Clock High to Output Valid Clock High to WAIT Valid Max 9 11 ns tKHQX tKHTX tCLKHQX Clock High to Output Transition Clock High to WAIT Transition Min 2 3 ns Min 4 5 ns 15 ns tLLKH Clock Specifications Alt tADVLCLKH Latch Enable Low to Clock High Clock Period (66 MHz) tKHKH tCLK Min Clock Period (f=86 MHz) 12 tKHKL tKLKH Clock High to Clock Low Clock Low to Clock High Min 3.5 3.5 ns tf tr Clock Fall or Rise Time Max 3 3 ns 1. Sampled only, not 100% tested. For other timings please refer to Table 24: Asynchronous Read ac characteristics. 70/123 tELLH tLLLH SET-UP COMMAND tGHLL tWLWH tWHLL tWHDX tWHWL tWHEH tDVWH COMMAND BANK ADDRESS tELWL tLHAX BANK ADDR. tAVAV VALID CONFIRM COMMAND tVPHWH tWPHWH tWHKV tWHEL CMD OR DATA VALID ADDRESS VALID ADDR. VALID AI13528 tQVVPL tQVWPL STATUS REGISTER READ 1ST POLLING tWHVPL tWHWPL tELQV STATUS REGISTER VALID tLHGL VALID ADDRESS VALID ADDR. Note 1: Amax is equal to A19 in the M58WR016KU/L, to A20 in the M58WR032KU/L, and to A21 in the M58WR064KU/L. K VPP WP W G E L tAVLH A16-Amax(1) ADQ0-ADQ15 BINV PROGRAM OR ERASE M58WRxxxKU, M58WRxxxKL DC and AC parameters Figure 16. Write ac waveforms, Write Enable controlled 71/123 DC and AC parameters Table 26. M58WRxxxKU, M58WRxxxKL Write ac characteristics, Write Enable controlled M58WRxxxKU/L Symbol tAVAV Alt tWC 70 Min 60 70 ns Address Valid to Latch Enable High Min 4 7 ns Data Valid to Write Enable High Min 40 40 ns Chip Enable Low to Latch Enable High Min 9 10 ns Chip Enable Low to Write Enable Low Min 0 0 ns tELQV Chip Enable Low to Output Valid Min 60 70 ns tGHLL Output Enable High to Latch Enable Low Min 14 20 ns tGHWL Output Enable High to Write Enable Low Min 14 20 ns tLHAX Latch Enable High to Address Transition Min 4 7 ns tLHGL Latch Enable High to Output Enable Low Min 4 5 ns tLLLH Latch Enable Pulse Width Min 7 7 ns tDVWH tDS tELLH tELWL Write Enable Controlled Timings Unit 60 Address Valid to Next Address Valid tAVLH tCS tWHDX tDH Write Enable High to Input Transition Min 0 0 ns tWHEH tCH Write Enable High to Chip Enable High Min 0 0 ns Write Enable High to Chip Enable Low Min 25 25 ns tWHGL Write Enable High to Output Enable Low Min 0 0 ns tWHLL(1) Write Enable High to Latch Enable Low Min 25 25 ns tWHEL(1) Protection Timings Parameter tWHWL tWPH Write Enable High to Write Enable Low Min 25 25 ns tWLWH tWP Write Enable Low to Write Enable High Min 40 45 ns tQVVPL Output (Status Register) Valid to VPP Low Min 0 0 ns tQVWPL Output (Status Register) Valid to Write Protect Low Min 0 0 ns VPP High to Write Enable High Min 200 200 ns tWHVPL Write Enable High to VPP Low Min 200 200 ns tWHWPL Write Enable High to Write Protect Low Min 200 200 ns tWPHWH Write Protect High to Write Enable High Min 200 200 ns tVPHWH tVPS 1. tWHEL and tWHLL have this value when reading from the targeted bank or when reading from any address after a Set Configuration Register command has been issued. System designers should take this into account and may insert a software No-Op instruction to delay the first read in the same bank after issuing any command, or to delay the first read to any address after issuing a Set Configuration Register command. If the first read after the command is a Read Array operation in a different bank and no changes to the Configuration Register have been issued, tWHEL and tWHLL are 0 ns. 2. Sampled only, not 100% tested. 72/123 tDVEH COMMAND SET-UP COMMAND tELEH tELLH tLLLH tAVLH BANK ADDRESS tGHLL tWLEL tLHAX BANK ADDR. tAVAV VALID tEHWH tEHEL tEHLL tEHDX CMD OR DATA CONFIRM COMMAND tVPHEH tWPHEH VALID ADDRESS VALID ADDR. VALID tWHKV tEHVPL tEHWPL tWHEL tELQV AI13529 tQVVPL tQVWPL STATUS REGISTER tLHGL VALID ADDRESS VALID ADDR. VALID PROGRAM OR ERASE STATUS REGISTER READ 1ST POLLING Note 1: Amax is equal to A19 in the M58WR016KU/L, to A20 in the M58WR032KU/L, and to A21 in the M58WR064KU/L. K VPP WP W G E L A16-Amax(1) ADQ0-ADQ15 BINV M58WRxxxKU, M58WRxxxKL DC and AC parameters Figure 17. Write ac waveforms, Chip Enable controlled 73/123 DC and AC parameters Table 27. M58WRxxxKU, M58WRxxxKL Write ac characteristics, Chip Enable controlled M58WRxxxKU/L Chip Enable Controlled Timings Symbol Alt Unit 60 70 tAVAV tWC Address Valid to Next Address Valid Min 60 70 ns tAVLH Address Valid to Latch Enable High Min 4 7 ns tDVEH tDS Data Valid to Chip Enable High Min 40 40 ns tEHDX tDH Chip Enable High to Input Transition Min 0 0 ns Min 25 25 ns Chip Enable High to Latch Enable Low Min 0 0 ns tEHEL tWPH Chip Enable High to Chip Enable Low tEHLL tEHWH tCH Chip Enable High to Write Enable High Min 0 0 ns tELEH tWP Chip Enable Low to Chip Enable High Min 40 45 ns tELLH Chip Enable Low to Latch Enable High Min 9 10 ns tELQV Chip Enable Low to Output Valid Min 60 70 ns tGHEL Output Enable High to Chip Enable Low Min 14 20 ns tGHLL Output Enable High to Latch Enable Low Min 14 20 ns tLHAX Latch Enable High to Address Transition Min 4 7 ns tLHGL Latch Enable High to Output Enable Low Min 4 5 ns tLLLH Latch Enable Pulse Width Min 7 7 ns Write Enable High to Chip Enable Low Min 25 25 ns Write Enable Low to Chip Enable Low Min 0 0 ns tEHVPL Chip Enable High to VPP Low Min 200 200 ns tEHWPL Chip Enable High to Write Protect Low Min 200 200 ns tQVVPL Output (Status Register) Valid to VPP Low Min 0 0 ns tQVWPL Output (Status Register) Valid to Write Protect Low Min 0 0 ns Min 200 200 ns Min 200 200 ns tWHEL(2) tWLEL Protection Timings Parameter tVPHEH tWPHEH tCS tVPS VPP High to Chip Enable High Write Protect High to Chip Enable High 1. Sampled only, not 100% tested. 2. tWHEL has this value when reading from the targeted bank or when reading from any address after a Set Configuration Register command has been issued. System designers should take this into account and may insert a software No-Op instruction to delay the first read in the same bank after issuing any command, or to delay the first read to any address after issuing a Set Configuration Register command. If the first read after the command is a Read Array operation in a different bank and no changes to the Configuration Register have been issued, tWHEL is 0 ns. 74/123 M58WRxxxKU, M58WRxxxKL DC and AC parameters Figure 18. Reset and Power-up ac waveforms tPHWL tPHEL tPHGL tPHLL W, E, G, L tPLWL tPLEL tPLGL tPLLL RP tVDHPH tPLPH VDD, VDDQ Power-Up Reset AI06976 Table 28. Symbol Reset and Power-up ac characteristics Parameter tPLWL tPLEL tPLGL tPLLL Reset Low to Write Enable Low, Chip Enable Low, Output Enable Low, Latch Enable Low tPHWL tPHEL tPHGL tPHLL Test Condition 60 70 Unit During Program Min 10 10 µs During Erase Min 20 20 µs After Power-Down Min 50 50 µs Other Conditions Min 80 80 ns Reset High to Write Enable Low Chip Enable Low Output Enable Low Latch Enable Low Min 30 30 ns tPLPH(1)(2) RP Pulse Width Min 50 50 ns tVDHPH(3) Supply Voltages High to Reset High Min 200 200 µs 1. The device Reset is possible but not guaranteed if tPLPH < 50 ns. 2. Sampled only, not 100% tested. 3. It is important to assert RP in order to allow proper CPU initialization during Power-Up or Reset. 75/123 Package mechanical 15 M58WRxxxKU, M58WRxxxKL Package mechanical In order to meet environmental requirements, Numonyx offers these devices in ECOPACK® packages. These packages have a Lead-free second-level interconnect. The category of Second-Level Interconnect is marked on the package and on the inner box label, in compliance with JEDEC Standard JESD97. The maximum ratings related to soldering conditions are also marked on the inner box label. Figure 19. VFBGA44 7.5 × 5 mm, 10 × 4 ball array, 0.50 mm pitch, bottom view package outline D D2 D1 FE FE1 SD E1 E2 E SE BALL "A1" FD1 e b FD A A1 A2 ddd BGA-Z52 1. Drawing is not to scale. 76/123 M58WRxxxKU, M58WRxxxKL Table 29. Package mechanical VFBGA44 7.5 × 5 mm, 10 × 4 ball array, 0.50 mm pitch, package mechanical data millimeters inches Symbol Typ Min A Max Typ Min 1.000 A1 Max 0.0394 0.150 0.0059 A2 0.660 0.0260 b 0.300 0.250 0.350 0.0118 0.0098 0.0138 D 7.500 7.400 7.600 0.2953 0.2913 0.2992 D1 4.500 0.1772 D2 6.500 0.2559 ddd 0.080 4.900 E 5.000 E1 1.500 0.0591 E2 3.500 0.1378 e 0.500 FD 1.500 0.0591 FD1 0.500 0.0197 FE 1.750 0.0689 FE1 0.750 0.0295 SD 0.250 0.0098 SE 0.250 0.0098 – 5.100 0.0031 – 0.1969 0.0197 0.1929 0.2008 – – 77/123 Part numbering 16 M58WRxxxKU, M58WRxxxKL Part numbering Table 30. Ordering information scheme Example: M58 W R 032 K U 70 ZA 6 E Device Type M58 Architecture W = Multiple Bank, Burst Mode Operating Voltage R = VDD = VDDQ = 1.7 V to 2 V Density 016 = 16 Mbit (× 16) 032 = 32 Mbit (× 16) 064 = 64 Mbit (× 16) Technology K = 65 nm technology Parameter Location U = Top Boot, Mux I/O L = Bottom Boot, Mux I/O Speed 60 = 60 ns 70 = 70 ns Package ZA = VFBGA44 7.5 x 5 mm, 0.50 mm pitch Temperature Range 6 = –40 to 85 °C Option E = ECOPACK® Package, Standard Packing U = ECOPACK® Package, Tape & Reel Packing, 16mm Devices are shipped from the factory with the memory content bits erased to ’1’. For a list of available options (Speed, Package, etc.), Daisy chain ordering information, or for further information on any aspect of this device, please contact the Numonyx Sales Office nearest to you. 78/123 M58WRxxxKU, M58WRxxxKL Appendix A Block address tables Table 31. (1) Bank 1 Parameter bank Bank Bank 2 Block address tables Top boot block addresses, M58WR016KU # Size (Kword) Address range 0 4 FF000-FFFFF 1 4 FE000-FEFFF 2 4 FD000-FDFFF 3 4 FC000-FCFFF 4 4 FB000-FBFFF 5 4 FA000-FAFFF 6 4 F9000-F9FFF 7 4 F8000-F8FFF 8 32 F0000-F7FFF 9 32 E8000-EFFFF 10 32 E0000-E7FFF 11 32 D8000-DFFFF 12 32 D0000-D7FFF 13 32 C8000-CFFFF 14 32 C0000-C7FFF 15 32 B8000-BFFFF 16 32 B0000-B7FFF 17 32 A8000-AFFFF 18 32 A0000-A7FFF 19 32 98000-9FFFF 20 32 90000-97FFF 21 32 88000-8FFFF 22 32 80000-87FFF 23 32 78000-7FFFF 24 32 70000-77FFF 25 32 68000-6FFFF 26 32 60000-67FFF 27 32 58000-5FFFF 28 32 50000-57FFF 29 32 48000-4FFFF 30 32 40000-47FFF 79/123 Block address tables Table 31. Bank 3 Bank(1) M58WRxxxKU, M58WRxxxKL Top boot block addresses, M58WR016KU (continued) # Size (Kword) Address range 31 32 38000-3FFFF 32 32 30000-37FFF 33 32 28000-2FFFF 34 32 20000-27FFF 35 32 18000-1FFFF 36 32 10000-17FFF 37 32 08000-0FFFF 38 32 00000-07FFF 1. There are two Bank Regions: Bank Region 1 contains all the banks that are made up of main blocks only; Bank Region 2 contains the banks that are made up of the parameter and main blocks (Parameter Bank). Table 32. Bank 2 Bank 3 Bank(1) 80/123 Bottom boot block addresses, M58WR016KL # Size (Kword) Address range 38 32 F8000-FFFFF 37 32 F0000-F7FFF 36 32 E8000-EFFFF 35 32 E0000-E7FFF 34 32 D8000-DFFFF 33 32 D0000-D7FFF 32 32 C8000-CFFFF 31 32 C0000-C7FFF 30 32 B8000-BFFFF 29 32 B0000-B7FFF 28 32 A8000-AFFFF 27 32 A0000-A7FFF 26 32 98000-9FFFF 25 32 90000-97FFF 24 32 88000-8FFFF 23 32 80000-87FFF M58WRxxxKU, M58WRxxxKL Table 32. Parameter Bank Bank 1 Bank(1) Block address tables Bottom boot block addresses, M58WR016KL (continued) # Size (Kword) Address range 22 32 78000-7FFFF 21 32 70000-77FFF 20 32 68000-6FFFF 19 32 60000-67FFF 18 32 58000-5FFFF 17 32 50000-57FFF 16 32 48000-4FFFF 15 32 40000-47FFF 14 32 38000-3FFFF 13 32 30000-37FFF 12 32 28000-2FFFF 11 32 20000-27FFF 10 32 18000-1FFFF 9 32 10000-17FFF 8 32 08000-0FFFF 7 4 07000-07FFF 6 4 06000-06FFF 5 4 05000-05FFF 4 4 04000-04FFF 3 4 03000-03FFF 2 4 02000-02FFF 1 4 01000-01FFF 0 4 00000-00FFF 1. There are two Bank Regions: Bank Region 2 contains all the banks that are made up of main blocks only; Bank Region 1 contains the banks that are made up of the parameter and main blocks (Parameter Bank). 81/123 Block address tables M58WRxxxKU, M58WRxxxKL Table 33. Top boot block addresses, M58WR032KU Bank 3 Bank 2 Bank 1 Parameter Bank Bank(1) 82/123 # Size (Kword) Address range 0 4 1FF000-1FFFFF 1 4 1FE000-1FEFFF 2 4 1FD000-1FDFFF 3 4 1FC000-1FCFFF 4 4 1FB000-1FBFFF 5 4 1FA000-1FAFFF 6 4 1F9000-1F9FFF 7 4 1F8000-1F8FFF 8 32 1F0000-1F7FFF 9 32 1E8000-1EFFFF 10 32 1E0000-1E7FFF 11 32 1D8000-1DFFFF 12 32 1D0000-1D7FFF 13 32 1C8000-1CFFFF 14 32 1C0000-1C7FFF 15 32 1B8000-1BFFFF 16 32 1B0000-1B7FFF 17 32 1A8000-1AFFFF 18 32 1A0000-1A7FFF 19 32 198000-19FFFF 20 32 190000-197FFF 21 32 188000-18FFFF 22 32 180000-187FFF 23 32 178000-17FFFF 24 32 170000-177FFF 25 32 168000-16FFFF 26 32 160000-167FFF 27 32 158000-15FFFF 28 32 150000-157FFF 29 32 148000-14FFFF 30 32 140000-147FFF 31 32 138000-13FFFF 32 32 130000-137FFF 33 32 128000-12FFFF 34 32 120000-127FFF 35 32 118000-11FFFF 36 32 110000-117FFF 37 32 108000-10FFFF 38 32 100000-107FFF M58WRxxxKU, M58WRxxxKL Table 33. Block address tables Top boot block addresses, M58WR032KU (continued) Bank 7 Bank 6 Bank 5 Bank 4 Bank(1) # Size (Kword) Address range 39 32 0F8000-0FFFFF 40 32 0F0000-0F7FFF 41 32 0E8000-0EFFFF 42 32 0E0000-0E7FFF 43 32 0D8000-0DFFFF 44 32 0D0000-0D7FFF 45 32 0C8000-0CFFFF 46 32 0C0000-0C7FFF 47 32 0B8000-0BFFFF 48 32 0B0000-0B7FFF 49 32 0A8000-0AFFFF 50 32 0A0000-0A7FFF 51 32 098000-09FFFF 52 32 090000-097FFF 53 32 088000-08FFFF 54 32 080000-087FFF 55 32 078000-07FFFF 56 32 070000-077FFF 57 32 068000-06FFFF 58 32 060000-067FFF 59 32 058000-05FFFF 60 32 050000-057FFF 61 32 048000-04FFFF 62 32 040000-047FFF 63 32 038000-03FFFF 64 32 030000-037FFF 65 32 028000-02FFFF 66 32 020000-027FFF 67 32 018000-01FFFF 68 32 010000-017FFF 69 32 008000-00FFFF 70 32 000000-007FFF 1. There are two Bank Regions: Bank Region 1 contains all the banks that are made up of main blocks only; Bank Region 2 contains the banks that are made up of the parameter and main blocks (Parameter Bank). 83/123 Block address tables M58WRxxxKU, M58WRxxxKL Table 34. Bottom boot block addresses, M58WR032KL Bank 4 Bank 5 Bank 6 Bank 7 Bank(1) 84/123 # Size (Kword) Address range 70 32 1F8000-1FFFFF 69 32 1F0000-1F7FFF 68 32 1E8000-1EFFFF 67 32 1E0000-1E7FFF 66 32 1D8000-1DFFFF 65 32 1D0000-1D7FFF 64 32 1C8000-1CFFFF 63 32 1C0000-1C7FFF 62 32 1B8000-1BFFFF 61 32 1B0000-1B7FFF 60 32 1A8000-1AFFFF 59 32 1A0000-1A7FFF 58 32 198000-19FFFF 57 32 190000-197FFF 56 32 188000-18FFFF 55 32 180000-187FFF 54 32 178000-17FFFF 53 32 170000-177FFF 52 32 168000-16FFFF 51 32 160000-167FFF 50 32 158000-15FFFF 49 32 150000-157FFF 48 32 148000-14FFFF 47 32 140000-147FFF 46 32 138000-13FFFF 45 32 130000-137FFF 44 32 128000-12FFFF 43 32 120000-127FFF 42 32 118000-11FFFF 41 32 110000-117FFF 40 32 108000-10FFFF 39 32 100000-107FFF M58WRxxxKU, M58WRxxxKL Table 34. Block address tables Bottom boot block addresses, M58WR032KL (continued) Bank 1 Bank 2 Bank 3 Bank(1) # Size (Kword) Address range 38 32 0F8000-0FFFFF 37 32 0F0000-0F7FFF 36 32 0E8000-0EFFFF 35 32 0E0000-0E7FFF 34 32 0D8000-0DFFFF 33 32 0D0000-0D7FFF 32 32 0C8000-0CFFFF 31 32 0C0000-0C7FFF 30 32 0B8000-0BFFFF 29 32 0B0000-0B7FFF 28 32 0A8000-0AFFFF 27 32 0A0000-0A7FFF 26 32 098000-09FFFF 25 32 090000-097FFF 24 32 088000-08FFFF 23 32 080000-087FFF 22 32 078000-07FFFF 21 32 070000-077FFF 20 32 068000-06FFFF 19 32 060000-067FFF 18 32 058000-05FFFF 17 32 050000-057FFF 16 32 048000-04FFFF 15 32 040000-047FFF 85/123 Block address tables M58WRxxxKU, M58WRxxxKL Table 34. Bottom boot block addresses, M58WR032KL (continued) Parameter Bank Bank(1) # Size (Kword) Address range 14 32 038000-03FFFF 13 32 030000-037FFF 12 32 028000-02FFFF 11 32 020000-027FFF 10 32 018000-01FFFF 9 32 010000-017FFF 8 32 008000-00FFFF 7 4 007000-007FFF 6 4 006000-006FFF 5 4 005000-005FFF 4 4 004000-004FFF 3 4 003000-003FFF 2 4 002000-002FFF 1 4 001000-001FFF 0 4 000000-000FFF 1. There are two Bank Regions: Bank Region 2 contains all the banks that are made up of main blocks only; Bank Region 1 contains the banks that are made up of the parameter and main blocks (Parameter Bank). 86/123 M58WRxxxKU, M58WRxxxKL Table 35. Block address tables Top boot block addresses, M58WR064KU Bank 3 Bank 2 Bank 1 Parameter bank Bank(1) # Size (Kword) Address range 0 4 3FF000-3FFFFF 1 4 3FE000-3FEFFF 2 4 3FD000-3FDFFF 3 4 3FC000-3FCFFF 4 4 3FB000-3FBFFF 5 4 3FA000-3FAFFF 6 4 3F9000-3F9FFF 7 4 3F8000-3F8FFF 8 32 3F0000-3F7FFF 9 32 3E8000-3EFFFF 10 32 3E0000-3E7FFF 11 32 3D8000-3DFFFF 12 32 3D0000-3D7FFF 13 32 3C8000-3CFFFF 14 32 3C0000-3C7FFF 15 32 3B8000-3BFFFF 16 32 3B0000-3B7FFF 17 32 3A8000-3AFFFF 18 32 3A0000-3A7FFF 19 32 398000-39FFFF 20 32 390000-397FFF 21 32 388000-38FFFF 22 32 380000-387FFF 23 32 378000-37FFFF 24 32 370000-377FFF 25 32 368000-36FFFF 26 32 360000-367FFF 27 32 358000-35FFFF 28 32 350000-357FFF 29 32 348000-34FFFF 30 32 340000-347FFF 31 32 338000-33FFFF 32 32 330000-337FFF 33 32 328000-32FFFF 34 32 320000-327FFF 35 32 318000-31FFFF 36 32 310000-317FFF 37 32 308000-30FFFF 38 32 300000-307FFF 87/123 Block address tables M58WRxxxKU, M58WRxxxKL Table 35. Top boot block addresses, M58WR064KU (continued) Bank 8 Bank 7 Bank 6 Bank 5 Bank 4 Bank(1) 88/123 # Size (Kword) Address range 39 32 2F8000-2FFFFF 40 32 2F0000-2F7FFF 41 32 2E8000-2EFFFF 42 32 2E0000-2E7FFF 43 32 2D8000-2DFFFF 44 32 2D0000-2D7FFF 45 32 2C8000-2CFFFF 46 32 2C0000-2C7FFF 47 32 2B8000-2BFFFF 48 32 2B0000-2B7FFF 49 32 2A8000-2AFFFF 50 32 2A0000-2A7FFF 51 32 298000-29FFFF 52 32 290000-297FFF 53 32 288000-28FFFF 54 32 280000-287FFF 55 32 278000-27FFFF 56 32 270000-277FFF 57 32 268000-26FFFF 58 32 260000-267FFF 59 32 258000-25FFFF 60 32 250000-257FFF 61 32 248000-24FFFF 62 32 240000-247FFF 63 32 238000-23FFFF 64 32 230000-237FFF 65 32 228000-22FFFF 66 32 220000-227FFF 67 32 218000-21FFFF 68 32 210000-217FFF 69 32 208000-20FFFF 70 32 200000-207FFF 71 32 1F8000-1FFFFF 72 32 1F0000-1F7FFF 73 32 1E8000-1EFFFF 74 32 1E0000-1E7FFF 75 32 1D8000-1DFFFF 76 32 1D0000-1D7FFF 77 32 1C8000-1CFFFF 78 32 1C0000-1C7FFF M58WRxxxKU, M58WRxxxKL Table 35. Block address tables Top boot block addresses, M58WR064KU (continued) Bank 13 Bank 12 Bank 11 Bank 10 Bank 9 Bank(1) # Size (Kword) Address range 79 32 1B8000-1BFFFF 80 32 1B0000-1B7FFF 81 32 1A8000-1AFFFF 82 32 1A0000-1A7FFF 83 32 198000-19FFFF 84 32 190000-197FFF 85 32 188000-18FFFF 86 32 180000-187FFF 87 32 178000-17FFFF 88 32 170000-177FFF 89 32 168000-16FFFF 90 32 160000-167FFF 91 32 158000-15FFFF 92 32 150000-157FFF 93 32 148000-14FFFF 94 32 140000-147FFF 95 32 138000-13FFFF 96 32 130000-137FFF 97 32 128000-12FFFF 98 32 120000-127FFF 99 32 118000-11FFFF 100 32 110000-117FFF 101 32 108000-10FFFF 102 32 100000-107FFF 103 32 0F8000-0FFFFF 104 32 0F0000-0F7FFF 105 32 0E8000-0EFFFF 106 32 0E0000-0E7FFF 107 32 0D8000-0DFFFF 108 32 0D0000-0D7FFF 109 32 0C8000-0CFFFF 110 32 0C0000-0C7FFF 111 32 0B8000-0BFFFF 112 32 0B0000-0B7FFF 113 32 0A8000-0AFFFF 114 32 0A0000-0A7FFF 115 32 098000-09FFFF 116 32 090000-097FFF 117 32 088000-08FFFF 118 32 080000-087FFF 89/123 Block address tables M58WRxxxKU, M58WRxxxKL Table 35. Top boot block addresses, M58WR064KU (continued) Bank 15 Bank 14 Bank(1) # Size (Kword) Address range 119 32 078000-07FFFF 120 32 070000-077FFF 121 32 068000-06FFFF 122 32 060000-067FFF 123 32 058000-05FFFF 124 32 050000-057FFF 125 32 048000-04FFFF 126 32 040000-047FFF 127 32 038000-03FFFF 128 32 030000-037FFF 129 32 028000-02FFFF 130 32 020000-027FFF 131 32 018000-01FFFF 132 32 010000-017FFF 133 32 008000-00FFFF 134 32 000000-007FFF 1. There are two Bank Regions: Bank Region 1 contains all the banks that are made up of main blocks only; Bank Region 2 contains the banks that are made up of the parameter and main blocks (Parameter Bank). Table 36. Bottom boot block addresses, M58WR064KL Bank 14 Bank 15 Bank(1) 90/123 # Size (Kword) Address range 134 32 3F8000-3FFFFF 133 32 3F0000-3F7FFF 132 32 3E8000-3EFFFF 131 32 3E0000-3E7FFF 130 32 3D8000-3DFFFF 129 32 3D0000-3D7FFF 128 32 3C8000-3CFFFF 127 32 3C0000-3C7FFF 126 32 3B8000-3BFFFF 125 32 3B0000-3B7FFF 124 32 3A8000-3AFFFF 123 32 3A0000-3A7FFF 122 32 398000-39FFFF 121 32 390000-397FFF 120 32 388000-38FFFF 119 32 380000-387FFF M58WRxxxKU, M58WRxxxKL Table 36. Block address tables Bottom boot block addresses, M58WR064KL (continued) Bank 10 Bank 11 Bank 12 Bank 13 Bank(1) # Size (Kword) Address range 118 32 378000-37FFFF 117 32 370000-377FFF 116 32 368000-36FFFF 115 32 360000-367FFF 114 32 358000-35FFFF 113 32 350000-357FFF 112 32 348000-34FFFF 111 32 340000-347FFF 110 32 338000-33FFFF 109 32 330000-337FFF 108 32 328000-32FFFF 107 32 320000-327FFF 106 32 318000-31FFFF 105 32 310000-317FFF 104 32 308000-30FFFF 103 32 300000-307FFF 102 32 2F8000-2FFFFF 101 32 2F0000-2F7FFF 100 32 2E8000-2EFFFF 99 32 2E0000-2E7FFF 98 32 2D8000-2DFFFF 97 32 2D0000-2D7FFF 96 32 2C8000-2CFFFF 95 32 2C0000-2C7FFF 94 32 2B8000-2BFFFF 93 32 2B0000-2B7FFF 92 32 2A8000-2AFFFF 91 32 2A0000-2A7FFF 90 32 298000-29FFFF 89 32 290000-297FFF 88 32 288000-28FFFF 87 32 280000-287FFF 91/123 Block address tables M58WRxxxKU, M58WRxxxKL Table 36. Bottom boot block addresses, M58WR064KL (continued) Bank 6 Bank 7 Bank 8 Bank 9 Bank(1) 92/123 # Size (Kword) Address range 86 32 278000-27FFFF 85 32 270000-277FFF 84 32 268000-26FFFF 83 32 260000-267FFF 82 32 258000-25FFFF 81 32 250000-257FFF 80 32 248000-24FFFF 79 32 240000-247FFF 78 32 238000-23FFFF 77 32 230000-237FFF 76 32 228000-22FFFF 75 32 220000-227FFF 74 32 218000-21FFFF 73 32 210000-217FFF 72 32 208000-20FFFF 71 32 200000-207FFF 70 32 1F8000-1FFFFF 69 32 1F0000-1F7FFF 68 32 1E8000-1EFFFF 67 32 1E0000-1E7FFF 66 32 1D8000-1DFFFF 65 32 1D0000-1D7FFF 64 32 1C8000-1CFFFF 63 32 1C0000-1C7FFF 62 32 1B8000-1BFFFF 61 32 1B0000-1B7FFF 60 32 1A8000-1AFFFF 59 32 1A0000-1A7FFF 58 32 198000-19FFFF 57 32 190000-197FFF 56 32 188000-18FFFF 55 32 180000-187FFF M58WRxxxKU, M58WRxxxKL Table 36. Block address tables Bottom boot block addresses, M58WR064KL (continued) Bank 2 Bank 3 Bank 4 Bank 5 Bank(1) # Size (Kword) Address range 54 32 178000-17FFFF 53 32 170000-177FFF 52 32 168000-16FFFF 51 32 160000-167FFF 50 32 158000-15FFFF 49 32 150000-157FFF 48 32 148000-14FFFF 47 32 140000-147FFF 46 32 138000-13FFFF 45 32 130000-137FFF 44 32 128000-12FFFF 43 32 120000-127FFF 42 32 118000-11FFFF 41 32 110000-117FFF 40 32 108000-10FFFF 39 32 100000-107FFF 38 32 0F8000-0FFFFF 37 32 0F0000-0F7FFF 36 32 0E8000-0EFFFF 35 32 0E0000-0E7FFF 34 32 0D8000-0DFFFF 33 32 0D0000-0D7FFF 32 32 0C8000-0CFFFF 31 32 0C0000-0C7FFF 30 32 0B8000-0BFFFF 29 32 0B0000-0B7FFF 28 32 0A8000-0AFFFF 27 32 0A0000-0A7FFF 26 32 098000-09FFFF 25 32 090000-097FFF 24 32 088000-08FFFF 23 32 080000-087FFF 93/123 Block address tables M58WRxxxKU, M58WRxxxKL Table 36. Bottom boot block addresses, M58WR064KL (continued) Parameter Bank Bank 1 Bank(1) # Size (Kword) Address range 22 32 078000-07FFFF 21 32 070000-077FFF 20 32 068000-06FFFF 19 32 060000-067FFF 18 32 058000-05FFFF 17 32 050000-057FFF 16 32 048000-04FFFF 15 32 040000-047FFF 14 32 038000-03FFFF 13 32 030000-037FFF 12 32 028000-02FFFF 11 32 020000-027FFF 10 32 018000-01FFFF 9 32 010000-017FFF 8 32 008000-00FFFF 7 4 007000-007FFF 6 4 006000-006FFF 5 4 005000-005FFF 4 4 004000-004FFF 3 4 003000-003FFF 2 4 002000-002FFF 1 4 001000-001FFF 0 4 000000-000FFF 1. There are two Bank Regions: Bank Region 2 contains all the banks that are made up of main blocks only; Bank Region 1 contains the banks that are made up of the parameter and main blocks (Parameter Bank). 94/123 M58WRxxxKU, M58WRxxxKL Appendix B Common Flash Interface Common Flash Interface The Common Flash Interface is a JEDEC approved, standardized data structure that can be read from the Flash memory device. It allows a system software to query the device to determine various electrical and timing parameters, density information and functions supported by the memory. The system can interface easily with the device, enabling the software to upgrade itself when necessary. When the Read CFI Query Command is issued the device enters CFI Query mode and the data structure is read from the memory. Tables 37, 38, 39, 40, 41, 42, 43, 44, 45 and 46 show the addresses used to retrieve the data. The Query data is always presented on the lowest order data outputs (DQ0-DQ7), the other outputs (DQ8-DQ15) are set to 0. The CFI data structure also contains a security area where a 64 bit unique security number is written (see Figure 6: Protection Register memory map). This area can be accessed only in Read mode by the final user. It is impossible to change the security number after it has been written by Numonyx. Issue a Read Array command to return to Read mode. Table 37. Query structure overview(1) Offset Sub-section name Description 00h Reserved Reserved for algorithm-specific information 10h CFI query identification string Command set ID and algorithm data offset 1Bh System interface information Device timing & voltage information 27h Device geometry definition Flash device layout P Primary algorithm-specific extended query Additional information specific to the primary table algorithm (optional) A Alternate algorithm-specific extended query table Additional information specific to the alternate algorithm (optional) Security code area Lock Protection Register Unique device Number and User Programmable OTP 80h 1. The Flash memory display the CFI data structure when CFI Query command is issued. In this table are listed the main sub-sections detailed in Tables 38, 39, 40 and 41. Query data is always presented on the lowest order data outputs. 95/123 Common Flash Interface Table 38. CFI query identification string Offset Sub-section name 00h 0020h 01h 8823h 8828h 88C0h 8824h 8829h 88C1h 02h reserved 03h DRC 04h-0Fh reserved 10h 0051h 11h 0052h 12h 0059h 13h 0003h 14h 0000h 15h 16h 96/123 M58WRxxxKU, M58WRxxxKL Description Value Manufacturer code Device code Numonyx M58WR016KU M58WR032KU M58WR064KU M58WR016KL M58WR032KL M58WR064KL Reserved Die revision code Reserved "Q" Query unique ASCII string "QRY" 0000h 18h 0000h 19h value = A = 0000h 1Ah 0000h "R" "Y" Primary algorithm command set and control interface ID code 16 bit ID code defining a specific algorithm offset = P = 0039h Address for primary algorithm extended query table (see Table 41) 0000h 17h Top Top Top Bottom Bottom Bottom p = 39h Alternate vendor command set and control interface ID code second vendor - specified algorithm supported NA Address for alternate algorithm extended query table NA M58WRxxxKU, M58WRxxxKL Table 39. Common Flash Interface CFI query system interface information Offset Data Description Value 1Bh 0017h VDD logic supply minimum Program/Erase or Write voltage bit 7 to 4 BCD value in volts bit 3 to 0 BCD value in 100 millivolts 1.7 V 1Ch 0020h VDD logic supply maximum Program/Erase or Write voltage bit 7 to 4 BCD value in volts bit 3 to 0 BCD value in 100 millivolts 2V 1Dh 0085h VPP [programming] supply minimum Program/Erase voltage bit 7 to 4 HEX value in volts bit 3 to 0 BCD value in 100 millivolts 8.5 V 1Eh 0095h VPP [programming] supply maximum Program/Erase voltage bit 7 to 4 HEX value in volts bit 3 to 0 BCD value in 100 millivolts 9.5 V 1Fh 0004h Typical time-out per single byte/word program = 2n µs 16 µs n 0000h Typical time-out for multi-byte program = 2 µs NA 21h 000Ah n Typical time-out per individual block erase = 2 ms 1s 22h 0000h Typical time-out for full chip erase = 2n ms NA 20h 23h 24h 0003h 0000h n Maximum time-out for word program = 2 times typical n Maximum time-out for multi-byte program = 2 times typical 2n 25h 0002h Maximum time-out per individual block erase = 26h 0000h Maximum time-out for chip erase = 2n times typical times typical 128 µs NA 4s NA 97/123 Common Flash Interface Table 40. Offset Word Mode 27h Top devices Data Description Value 0015h M58WR016KU/L Device size = 2n in number of bytes 2 Mbytes 0016h M58WR032KU/L Device size = 2n in number of bytes 4 Mbytes n M58WR064KU/L Device size = 2 in number of bytes 28h 29h 0001h 0000h Flash device interface code description 2Ah 2Bh 0000h 0000h Maximum number of bytes in multi-byte program or page = 2n 2Ch 0002h Number of identical sized Erase block regions within the device bit 7 to 0 = x = number of Erase block regions 2 001Eh 0000h M58WR016KU region 1 information Number of identical-size Erase blocks = 001Eh+1 31 003Eh 0000h M58WR032KU region 1 information Number of identical-size Erase blocks = 003Eh+1 63 007Eh 0000h M58WR064KU region 1 information Number of identical-size Erase blocks = 007Eh+1 127 2Fh 30h 0000h 0001h Region 1 information Block size in region 1 = 0100h * 256 byte 31h 32h 0007h 0000h Region 2 information Number of identical-size Erase blocks = 0007h+1 33h 34h 0020h 0000h Region 2 information Block size in region 2 = 0020h * 256 byte 35h 38h Bottom devices Device geometry definition 0017h 2Dh 2Eh Reserved for future Erase block region information 8 Mbytes x 16 Async. NA 64 Kbyte 8 8 Kbyte NA 2Dh 2Eh 0007h 0000h Region 1 information Number of identical-size Erase block = 0007h+1 2Fh 30h 0020h 0000h Region 1 information Block size in region 1 = 0020h * 256 byte 001Eh 0000h M58WR016KL region 1 information Number of identical-size Erase blocks = 001Eh+1 31 003Eh 0000h M58WR032KL region 1 information Number of identical-size Erase blocks = 003Eh+1 63 007Eh 0000h M58WR064KL region 1 information Number of identical-size Erase blocks = 007Eh+1 127 0000h 0001h Region 2 information Block size in region 2 = 0100h * 256 byte 31h 32h 33h 34h 35h 38h 98/123 M58WRxxxKU, M58WRxxxKL Reserved for future Erase block region information 8 8 Kbyte 64 Kbyte NA M58WRxxxKU, M58WRxxxKL Table 41. Common Flash Interface Primary algorithm-specific extended query table(1) Offset Data (P)h = 39h 0050h 0052h Description Value "P" Primary algorithm extended query table unique ASCII string “PRI” 0049h "R" "I" (P+3)h = 3Ch 0031h Major version number, ASCII "1" (P+4)h = 3Dh 0033h Minor version number, ASCII "3" (P+5)h = 3Eh 00E6h Extended query table contents for primary algorithm. Address (P+5)h contains less significant byte. 0003h (P+7)h = 40h (P+8)h = 41h 0000h 0000h bit 0Chip Erase supported(1 = Yes, 0 = No) bit 1Erase Suspend supported(1 = Yes, 0 = No) bit 2Program Suspend supported(1 = Yes, 0 = No) bit 3Legacy Lock/Unlock supported(1 = Yes, 0 = No) bit 4Queued Erase supported(1 = Yes, 0 = No) bit 5Instant individual block locking supported(1 = Yes, 0 = No) bit 6Protection bits supported(1 = Yes, 0 = No) bit 7Page mode read supported(1 = Yes, 0 = No) bit 8Synchronous read supported(1 = Yes, 0 = No) bit 9Simultaneous operation supported(1 = Yes, 0 = No) bit 10 to 31Reserved; undefined bits are ‘0’. If bit 31 is ’1’ then another 31 bit field of optional features follows at the end of the bit-30 field. No Yes Yes No No Yes Yes Yes Yes Yes Supported Functions after Suspend Read Array, Read Status Register and CFI Query (P+9)h = 42h Yes 0001h bit 0Program supported after Erase Suspend (1 = Yes, 0 = No) bit 7 to 1Reserved; undefined bits are ‘0’ (P+A)h = 43h 0003h Block Protect Status Defines which bits in the Block Status Register section of the Query are implemented. (P+B)h = 44h 0000h bit 0Block protect Status Register Lock/Unlock bit active(1 = Yes, 0 = No) bit 1Block Lock Status Register Lock-Down bit active (1 = Yes, 0 = No) bit 15 to 2Reserved for future use; undefined bits are ‘0’ Yes Yes VDD Logic Supply Optimum Program/Erase voltage (highest performance) (P+C)h = 45h 0018h bit 7 to 4HEX value in volts bit 3 to 0BCD value in 100 mV 1.8 V VPP Supply Optimum Program/Erase voltage (P+D)h = 46h 0090h bit 7 to 4HEX value in volts bit 3 to 0BCD value in 100 mV 9V 1. The variable P is a pointer that is defined at CFI offset 15h. 99/123 Common Flash Interface Table 42. M58WRxxxKU, M58WRxxxKL Protection Register information(1) Offset Data (P+E)h = 47h 0001h (P+F)h = 48h 0080h (P+10)h = 49h 0000h (P+11)h = 4Ah 0003h (P+12)h= 4Bh 0004h Description Value Number of protection register fields in JEDEC ID space. 0000h indicates that 256 fields are available. Protection Field 1: protection description Bits 0-7 Lower byte of protection register address Bits 8-15 Upper byte of protection register address Bits 16-23 2n bytes in factory pre-programmed region Bits 24-31 2n bytes in user programmable region 1 0080h 8 Bytes 16 Bytes 1. The variable P is a pointer that is defined at CFI offset 15h. Table 43. Burst Read Information(1) Offset Data Description Value (P+13)h = 4Ch 0003h Page-mode read capability bits 0-7’n’ such that 2n HEX value represents the number of read-page bytes. See offset 28h for device word width to determine page-mode data output width. (P+14)h = 4Dh 0004h Number of synchronous mode read configuration fields that follow. 4 (P+15)h = 4Eh 0001h Synchronous mode read capability configuration 1 bit 3-7Reserved bit 0-2’n’ such that 2n+1 HEX value represents the maximum number of continuous synchronous reads when the device is configured for its maximum word width. A value of 07h indicates that the device is capable of continuous linear bursts that will output data until the internal burst counter reaches the end of the device’s burstable address space. This field’s 3-bit value can be written directly to the read configuration register bit 0-2 if the device is configured for its maximum word width. See offset 28h for word width to determine the burst data output width. 4 (P+16)h = 4Fh 0002h Synchronous mode read capability configuration 2 8 (P+17)h = 50h 0003h Synchronous mode read capability configuration 3 16 (P+18)h = 51h 0007h Synchronous mode read capability configuration 4 Cont. 1. The variable P is a pointer that is defined at CFI offset 15h. Table 44. Bank and Erase block region information M58WR032KU M58WR032KL Description Offset Data Offset Data (P+19)h = 52h 02h (P+19)h = 52h 02h Number of Bank Regions within the device 1. The variable P is a pointer that is defined at CFI offset 15h. 2. Bank Regions. There are two Bank Regions, see Tables 31, 32, 33, 34, 35 and 36. 100/123 8 Bytes M58WRxxxKU, M58WRxxxKL Table 45. Common Flash Interface Bank and Erase block region 1 information(1) M58WR016KU, M58WR032KU, M58WR064KU M58WR016KL, M58WR032KL, M58WR064KL Offset Data Offset Data (P+1A)h = 53h 03h(2) 07h(3) 0Fh(4) (P+1A)h = 53h 01h 00h (P+1B)h = 54h (P+1B)h = 54h (P+1C)h = 55h (P+1D)h = 56h (P+1E)h = 57h 11h 00h 00h Number of identical banks within Bank Region 1 (P+1C)h = 55h (P+1D)h = 56h (P+1E)h = 57h 00h 11h Number of program or erase operations allowed in Bank Region 1: Bits 0-3: Number of simultaneous program operations Bits 4-7: Number of simultaneous erase operations 00h Number of program or erase operations allowed in other banks while a bank in same region is programming Bits 0-3: Number of simultaneous program operations Bits 4-7: Number of simultaneous erase operations 00h Number of program or erase operations allowed in other banks while a bank in this region is erasing Bits 0-3: Number of simultaneous program operations Bits 4-7: Number of simultaneous erase operations Types of erase block regions in Bank Region 1 n = number of erase block regions with contiguous samesize erase blocks. Symmetrically blocked banks have one blocking region.(5) (P+1F)h = 58h 01h (P+1F)h = 58h 02h (P+20)h = 59h 07h (P+20)h = 59h 07h (P+21)h = 5Ah 00h (P+21)h = 5Ah 00h (P+22)h = 5Bh 00h (P+22)h = 5Bh 20h (P+23)h = 5Ch 01h (P+23)h = 5Ch 00h (P+24)h = 5Dh 64h (P+24)h = 5Dh 64h (P+25)h = 5Eh 00h (P+25)h = 5Eh 00h (P+26)h = 5Fh (P+27)h = 60h 01h 03h Description (P+26)h = 5Fh (P+27)h = 60h Bank Region 1 Erase Block Type 1 Information Bits 0-15: n+1 = number of identical-sized erase blocks Bits 16-31: n×256 = number of bytes in erase block region Bank Region 1 (Erase Block Type 1) Minimum block erase cycles × 1000 01h Bank Region 1 (Erase Block Type 1): bits per cell, internal ECC Bits 0-3: bits per cell in erase region Bit 4: reserved for “internal ECC used” BIts 5-7: reserved 5Eh 01 5Eh 01 03h Bank Region 1 (Erase Block Type 1): Page mode and synchronous mode capabilities Bit 0: Page-mode reads permitted Bit 1: Synchronous reads permitted Bit 2: Synchronous writes permitted Bits 3-7: reserved 101/123 Common Flash Interface Table 45. Bank and Erase block region 1 information(1) (continued) M58WR016KU, M58WR032KU, M58WR064KU Offset M58WRxxxKU, M58WRxxxKL Data M58WR016KL, M58WR032KL, M58WR064KL Description Offset Data (P+28)h = 61h 06h Bank Region 1 Erase Block Type 2 Information (P+29)h = 62h 00h (P+2A)h = 63h 00h Bits 0-15: n+1 = number of identical-sized erase blocks (P+2B)h = 64h 01h Bits 16-31: n×256 = number of bytes in erase block region (P+2C)h = 65h 64h (P+2D)h = 66h 00h Bank Region 1 (Erase Block Type 2) Minimum block erase cycles × 1000 (P+2E)h = 67h (P+2F)h = 68h 01h Bank Regions 1 (Erase Block Type 2): bits per cell, internal ECC Bits 0-3: bits per cell in erase region Bit 4: reserved for “internal ECC used” BIts 5-7: reserved 03h Bank Region 1 (Erase Block Type 2): Page mode and synchronous mode capabilities Bit 0: Page-mode reads permitted Bit 1: Synchronous reads permitted Bit 2: Synchronous writes permitted Bits 3-7: reserved 1. The variable P is a pointer that is defined at CFI offset 15h. 2. Applies to M58WR016KU. 3. Applies to M58WR032KU. 4. Applies to M58WR064KU. 5. Bank Regions. There are two Bank Regions, see Tables 31, 32, 33, 34, 35 and 36. 102/123 M58WRxxxKU, M58WRxxxKL Table 46. Common Flash Interface Bank and Erase block region 2 information(1) M58WR016KU, M58WR032KU, M58WR064KU M58WR016KL, M58WR032KL, M58WR064KL Offset Offset Data (P+30)h = 69h 03h(2) 07h(3) 0Fh(4) (P+28)h = 61h (P+29)h = 62h (P+2A)h = 63h (P+2B)h = 64h (P+2C)h = 65h Data 01h 00h 11h 00h 00h (P+31)h = 6Ah (P+32)h = 6Bh (P+33)h = 6Ch (P+34)h = 6Dh 11h Number of program or erase operations allowed in Bank Region 2: Bits 0-3: number of simultaneous program operations Bits 4-7: number of simultaneous erase operations 00h Number of program or erase operations allowed in other banks while a bank in this region is programming Bits 0-3: number of simultaneous program operations Bits 4-7: number of simultaneous erase operations 00h Number of program or erase operations allowed in other banks while a bank in this region is erasing Bits 0-3: number of simultaneous program operations Bits 4-7: number of simultaneous erase operations Types of erase block regions in Bank Region 2 n = number of erase block regions with contiguous same-size erase blocks. Symmetrically blocked banks have one blocking region.(5) 02h (P+35)h = 6Eh 01h (P+2E)h = 67h 06h (P+36)h = 6Fh 07h (P+2F)h = 68h 00h (P+37)h = 70h 00h (P+30)h = 69h 00h (P+38)h = 71h 00h (P+31)h = 6Ah 01h (P+39)h = 72h 01h (P+32)h = 6Bh 64h (P+3A)h = 73h 64h (P+33)h = 6Ch 00h (P+3B)h = 74h 00h (P+35)h = 6Eh 01h 03h (P+3C)h = 75h (P+3D)h = 76h Number of identical banks within Bank Region 2 00h (P+2D)h = 66h (P+34)h = 6Dh Description Bank Region 2 Erase Block Type 1 Information Bits 0-15: n+1 = number of identical-sized erase blocks Bits 16-31: n×256 = number of bytes in erase block region Bank Region 2 (Erase Block Type 1) Minimum block erase cycles × 1000 01h Bank Region 2 (Erase Block Type 1): bits per cell, internal ECC Bits 0-3: bits per cell in erase region Bit 4: reserved for “internal ECC used” Bits 5-7: reserved 03h Bank Region 2 (Erase Block Type 1): Page mode and synchronous mode capabilities (defined in Table 43) Bit 0: page-mode reads permitted Bit 1: synchronous reads permitted Bit 2: synchronous writes permitted Bits 3-7: reserved 103/123 Common Flash Interface Table 46. M58WRxxxKU, M58WRxxxKL Bank and Erase block region 2 information(1) (continued) M58WR016KU, M58WR032KU, M58WR064KU M58WR016KL, M58WR032KL, M58WR064KL Offset Data Offset (P+36)h = 6Fh 07h (P+37)h = 70h 00h (P+38)h = 71h 20h (P+39)h = 72h 00h (P+3A)h = 73h 64h (P+3B)h = 74h 00h (P+3C)h = 75h (P+3D)h = 76h Description Data Bank Region 2 Erase Block Type 2 Information Bits 0-15: n+1 = number of identical-sized erase blocks Bits 16-31: n×256 = number of bytes in erase block region Bank Region 2 (Erase Block Type 2) Minimum block erase cycles × 1000 01h Bank Region 2 (Erase Block Type 2): bits per cell, internal ECC Bits 0-3: bits per cell in erase region Bit 4: reserved for “internal ECC used” Bits 5-7: reserved 03h Bank Region 2 (Erase Block Type 2): Page mode and synchronous mode capabilities (defined in Table 43) Bit 0: Page-mode reads permitted Bit 1: Synchronous reads permitted Bit 2: Synchronous writes permitted Bits 3-7: reserved (P+3E)h = 77h (P+3E)h = 77h Feature space definitions (P+3F)h = 78h (P+3F)h = 78h Reserved 1. The variable P is a pointer that is defined at CFI offset 15h. 2. Applies to M58WR016KL. 3. Applies to M58WR032KL. 4. Applies to M58WR064KL. 5. Bank Regions. There are two Bank Regions, see Tables 31, 32, 33, 34, 35 and 36. 104/123 M58WRxxxKU, M58WRxxxKL Appendix C Flowcharts and pseudocodes Flowcharts and pseudocodes Figure 20. Program flowchart and pseudocode Start program_command (addressToProgram, dataToProgram) {: writeToFlash (addressToProgram, 0x40); /*writeToFlash (addressToProgram, 0x10);*/ /*see note (3)*/ Write 40h or 10h (3) writeToFlash (addressToProgram, dataToProgram) ; /*Memory enters read status state after the Program Command*/ Write Address & Data do { status_register=readFlash (addressToProgram); "see note (3)"; /* E or G must be toggled*/ Read Status Register (3) SR7 = 1 NO } while (status_register.SR7== 0) ; YES SR3 = 0 NO VPP Invalid Error (1, 2) if (status_register.SR3==1) /*VPP invalid error */ error_handler ( ) ; NO Program Error (1, 2) if (status_register.SR4==1) /*program error */ error_handler ( ) ; NO Program to Protected Block Error (1, 2) YES SR4 = 0 YES SR1 = 0 if (status_register.SR1==1) /*program to protect block error */ error_handler ( ) ; YES End } AI06170c 1. Status check of SR1 (Protected Block), SR3 (VPP Invalid) and SR4 (Program Error) can be made after each program operation or after a sequence. 2. If an error is found, the Status Register must be cleared before further Program/Erase Controller operations. 3. Any address within the bank can equally be used. 105/123 Flowcharts and pseudocodes M58WRxxxKU, M58WRxxxKL Figure 21. Double Word Program flowchart and pseudocode Start Write 35h double_word_program_command (addressToProgram1, dataToProgram1, addressToProgram2, dataToProgram2) { writeToFlash (addressToProgram1, 0x35); /*see note (4)*/ writeToFlash (addressToProgram1, dataToProgram1) ; /*see note (3) */ writeToFlash (addressToProgram2, dataToProgram2) ; /*see note (3) */ /*Memory enters read status state after the Program command*/ Write Address 1 & Data 1 (3, 4) Write Address 2 & Data 2 (3) do { status_register=readFlash (addressToProgram) ; "see note (4)" /* E or G must be toggled*/ Read Status Register (4) SR7 = 1 NO } while (status_register.SR7== 0) ; YES SR3 = 0 NO VPP Invalid Error (1, 2) if (status_register.SR3==1) /*VPP invalid error */ error_handler ( ) ; NO Program Error (1, 2) if (status_register.SR4==1) /*program error */ error_handler ( ) ; NO Program to Protected Block Error (1, 2) YES SR4 = 0 YES SR1 = 0 if (status_register.SR1==1) /*program to protect block error */ error_handler ( ) ; YES End } AI06171b 1. Status check of b1 (Protected Block), b3 (VPP Invalid) and b4 (Program Error) can be made after each program operation or after a sequence. 2. If an error is found, the Status Register must be cleared before further Program/Erase operations. 3. Address 1 and Address 2 must be consecutive addresses differing only for bit A0. 4. Any address within the bank can equally be used. 106/123 M58WRxxxKU, M58WRxxxKL Flowcharts and pseudocodes Figure 22. Quadruple Word Program flowchart and pseudocode Start quadruple_word_program_command (addressToProgram1, dataToProgram1, addressToProgram2, dataToProgram2, addressToProgram3, dataToProgram3, addressToProgram4, dataToProgram4) { writeToFlash (addressToProgram1, 0x56); /*see note (4) */ Write 56h Write Address 1 & Data 1 (3, 4) writeToFlash (addressToProgram1, dataToProgram1) ; /*see note (3) */ Write Address 2 & Data 2 (3) writeToFlash (addressToProgram2, dataToProgram2) ; /*see note (3) */ writeToFlash (addressToProgram3, dataToProgram3) ; /*see note (3) */ Write Address 3 & Data 3 (3) writeToFlash (addressToProgram4, dataToProgram4) ; /*see note (3) */ Write Address 4 & Data 4 (3) /*Memory enters read status state after the Program command*/ do { status_register=readFlash (addressToProgram) ; /"see note (4) "/ /* E or G must be toggled*/ Read Status Register (4) SR7 = 1 NO } while (status_register.SR7== 0) ; YES SR3 = 0 NO VPP Invalid Error (1, 2) if (status_register.SR3==1) /*VPP invalid error */ error_handler ( ) ; NO Program Error (1, 2) if (status_register.SR4==1) /*program error */ error_handler ( ) ; NO Program to Protected Block Error (1, 2) YES SR4 = 0 YES SR1 = 0 if (status_register.SR==1) /*program to protect block error */ error_handler ( ) ; YES End } AI06977b 1. Status check of SR1 (Protected Block), SR3 (VPP Invalid) and SR4 (Program Error) can be made after each program operation or after a sequence. 2. If an error is found, the Status Register must be cleared before further Program/Erase operations. 3. Address 1 to Address 4 must be consecutive addresses differing only for bits A0 and A1. 4. Any address within the bank can equally be used. 107/123 Flowcharts and pseudocodes M58WRxxxKU, M58WRxxxKL Figure 23. Program Suspend & Resume flowchart and pseudocode Start program_suspend_command ( ) { writeToFlash (any_address, 0xB0) ; Write B0h writeToFlash (bank_address, 0x70) ; /* read status register to check if program has already completed */ Write 70h do { status_register=readFlash (bank_address) ; /* E or G must be toggled*/ Read Status Register SR7 = 1 NO } while (status_register.SR7== 0) ; YES SR2 = 1 NO Program Complete if (status_register.SR2==0) /*program completed */ { writeToFlash (bank_address, 0xFF) ; read_data ( ) ; /*The device returns to Read Array (as if program/erase suspend was not issued).*/ Write FFh YES Read Data } else Write FFh { writeToFlash (bank_address, 0xFF) ; Read data from another address read_data ( ); /*read data from another address*/ writeToFlash (any_address, 0xD0) ; /*write 0xD0 to resume program*/ Write D0h writeToFlash (bank_address, 0x70) ; /*read status register to check if program has completed */ Write 70h(1) } Program Continues with Bank in Read Status Register Mode } AI10117b 1. The Read Status Register command (Write 70h) can be issued just before or just after the Program Resume command. 108/123 M58WRxxxKU, M58WRxxxKL Flowcharts and pseudocodes Figure 24. Block Erase flowchart and pseudocode Start erase_command ( blockToErase ) { writeToFlash (blockToErase, 0x20) ; /*see note (2) */ Write 20h (2) writeToFlash (blockToErase, 0xD0) ; /* only ADQ12-ADQ15 and A16-Amax(3) are significant */ /* Memory enters read status state after the Erase Command */ Write Block Address & D0h do { status_register=readFlash (blockToErase) ; /* see note (2) */ /* E or G must be toggled*/ Read Status Register (2) SR7 = 1 NO } while (status_register.SR7== 0) ; YES SR3 = 0 NO VPP Invalid Error (1) YES Command Sequence Error (1) if (status_register.SR3==1) /*VPP invalid error */ error_handler ( ) ; YES SR4, SR5 = 1 if ( (status_register.SR4==1) && (status_register.SR5==1) ) /* command sequence error */ error_handler ( ) ; NO SR5 = 0 NO Erase Error (1) if ( (status_register.SR5==1) ) /* erase error */ error_handler ( ) ; YES SR1 = 0 NO Erase to Protected Block Error (1) if (status_register.SR1==1) /*program to protect block error */ error_handler ( ) ; YES End } AI13531 1. If an error is found, the Status Register must be cleared before further Program/Erase operations. 2. Any address within the bank can equally be used. 3. Amax is equal to A19 in the M58WR016KU/L, to A20 in the M58WR032KU/L, and to A21 in the M58WR064KU/L. 109/123 Flowcharts and pseudocodes M58WRxxxKU, M58WRxxxKL Figure 25. Erase Suspend & Resume flowchart and pseudocode Start erase_suspend_command ( ) { writeToFlash (bank_address, 0xB0) ; Write B0h writeToFlash (bank_address, 0x70) ; /* read status register to check if erase has already completed */ Write 70h do { status_register=readFlash (bank_address) ; /* E or G must be toggled*/ Read Status Register SR7 = 1 NO } while (status_register.SR7== 0) ; YES SR6 = 1 NO Erase Complete if (status_register.SR6==0) /*erase completed */ { writeToFlash (bank_address, 0xFF) ; Write FFh read_data ( ) ; /*The device returns to Read Array (as if program/erase suspend was not issued).*/ Read Data YES Write FFh } else { writeToFlash (bank_address, 0xFF) ; read_program_data ( ); Read data from another block, Program, /*read or program data from another block*/ Set Configuration Register or Block Lock/Unlock/Lock-Down writeToFlash (bank_address, 0xD0) ; /*write 0xD0 to resume erase*/ Write D0h writeToFlash (bank_address, 0x70) ; /*read status register to check if erase has completed */ Write 70h(1) Erase Continues with Bank in Read Status Register Mode } } AI13530b 1. The Read Status Register command (Write 70h) can be issued just before or just after the Erase Resume command. 110/123 M58WRxxxKU, M58WRxxxKL Flowcharts and pseudocodes Figure 26. Locking operations flowchart and pseudocode Start locking_operation_command (address, lock_operation) { writeToFlash (address, 0x60) ; /*configuration setup*/ /* see note (1) */ Write 60h (1) if (lock_operation==LOCK) /*to protect the block*/ writeToFlash (address, 0x01) ; else if (lock_operation==UNLOCK) /*to unprotect the block*/ writeToFlash (address, 0xD0) ; else if (lock_operation==LOCK-DOWN) /*to lock the block*/ writeToFlash (address, 0x2F) ; Write 01h, D0h or 2Fh writeToFlash (address, 0x90) ; /*see note (1) */ Write 90h (1) Read Block Lock States Locking change confirmed? if (readFlash (address) ! = locking_state_expected) error_handler () ; /*Check the locking state (see Read Block Signature table )*/ NO YES writeToFlash (address, 0xFF) ; /*Reset to Read Array mode*/ /*see note (1) */ Write FFh (1) } End AI06176b 1. Any address within the bank can equally be used. 111/123 Flowcharts and pseudocodes M58WRxxxKU, M58WRxxxKL Figure 27. Protection Register Program flowchart and pseudocode Start protection_register_program_command (addressToProgram, dataToProgram) {: writeToFlash (addressToProgram, 0xC0) ; /*see note (3) */ Write C0h (3) writeToFlash (addressToProgram, dataToProgram) ; /*Memory enters read status state after the Program Command*/ Write Address & Data do { status_register=readFlash (addressToProgram) ; /* see note (3) */ /* E or G must be toggled*/ Read Status Register (3) SR7 = 1 NO } while (status_register.SR7== 0) ; YES SR3 = 0 NO VPP Invalid Error (1, 2) if (status_register.SR3==1) /*VPP invalid error */ error_handler ( ) ; NO Program Error (1, 2) if (status_register.SR4==1) /*program error */ error_handler ( ) ; NO Program to Protected Block Error (1, 2) YES SR4 = 0 YES SR1 = 0 if (status_register.SR1==1) /*program to protect block error */ error_handler ( ) ; YES End } AI06177b 1. Status check of SR1 (Protected Block), SR3 (VPP Invalid) and SR4 (Program Error) can be made after each program operation or after a sequence. 2. If an error is found, the Status Register must be cleared before further Program/Erase Controller operations. 3. Any address within the bank can equally be used. 112/123 M58WRxxxKU, M58WRxxxKL Flowcharts and pseudocodes Figure 28. Enhanced Factory Program flowchart SETUP PHASE VERIFY PHASE Start Write PD1 Address WA1(1) Write 30h Address WA1 Write D0h Address WA1 Read Status Register Read Status Register SR0 = 0? NO Check SR4, SR3 and SR1 for program, VPP and Lock Errors SR7 = 0? Exit PROGRAM PHASE YES Write PD2 Address WA2(1) YES SR0 = 0? NO NO YES Read Status Register Write PD1 Address WA1 SR0 = 0? Read Status Register NO YES NO SR0 = 0? Write PDn Address WAn(1) YES Write PD2 Address WA2(1) Read Status Register Read Status Register SR0 = 0? NO YES SR0 = 0? NO Write FFFFh Address =/ Block WA1 YES EXIT PHASE Write PDn Address WAn(1) Read Status Register Read Status Register SR7 = 1? NO YES SR0 = 0? NO Check Status Register for Errors YES Write FFFFh Address =/ Block WA1 End AI06160 1. Address can remain Starting Address WA1 or be incremented. 113/123 Flowcharts and pseudocodes 16.1 M58WRxxxKU, M58WRxxxKL Enhanced Factory Program pseudocode efp_command(addressFlow,dataFlow,n) /* n is the number of data to be programmed */ { /* setup phase */ writeToFlash(addressFlow[0],0x30); writeToFlash(addressFlow[0],0xD0); status_register=readFlash(any_address); if (status_register.SR7==1){ /*EFP aborted for an error*/ if (status_register.SR4==1) /*program error*/ error_handler(); if (status_register.SR3==1) /*VPP invalid error*/ error_handler(); if (status_register.SR1==1) /*program to protect block error*/ error_handler(); } else{ /*Program Phase*/ do{ status_register=readFlash(any_address); /* E or G must be toggled*/ } while (status_register.SR0==1) /*Ready for first data*/ for (i=0; i++; i< n){ writeToFlash(addressFlow[i],dataFlow[i]); /* status register polling*/ do{ status_register=readFlash(any_address); /* E or G must be toggled*/ } while (status_register.SR0==1); /* Ready for a new data */ } writeToFlash(another_block_address,FFFFh); /* Verify Phase */ for (i=0; i++; i< n){ writeToFlash(addressFlow[i],dataFlow[i]); /* status register polling*/ do{ status_register=readFlash(any_address); /* E or G must be toggled*/ } while (status_register.SR0==1); /* Ready for a new data */ } writeToFlash(another_block_address,FFFFh); /* exit program phase */ /* Exit Phase */ /* status register polling */ do{ status_register=readFlash(any_address); /* E or G must be toggled */ } while (status_register.SR7==0); if (status_register.SR4==1) /*program failure error*/ error_handler(); if (status_register.SR3==1) /*VPP invalid error*/ error_handler(); if (status_register.SR1==1) /*program to protect block error*/ error_handler(); } } 114/123 M58WRxxxKU, M58WRxxxKL Flowcharts and pseudocodes Figure 29. Quadruple enhanced factory program flowchart SETUP PHASE LOAD PHASE Start Write 75h Address WA1 FIRST LOAD PHASE Write PD1 Address WA1 Read Status Register Write PD1 Address WA1(1) Write PD2 Address WA2(2) Write PD3 Address WA3(2) NO SR7 = 0? YES Write PD4 Address WA4(2) EXIT PHASE Check SR4, SR3 and SR1 for program, VPP and Lock Errors PROGRAM AND VERIFY PHASE Read Status Register Write FFFFh Address = / Block WA1 Exit NO SR0 = 0? YES Check SR4 for Programming Errors End Last Page? NO YES AI06178b 1. Address can remain Starting Address WA1 (in which case the next Page is programmed) or can be any address in the same block. 2. The address is only checked for the first word of each Page as the order to program the words is fixed, so subsequent words in each Page can be written to any address. 115/123 Flowcharts and pseudocodes 16.2 M58WRxxxKU, M58WRxxxKL Quadruple enhanced factory program pseudocode quad_efp_command(addressFlow,dataFlow,n) /* n is the number of pages to be programmed.*/ { /* Setup phase */ writeToFlash(addressFlow[0],0x75); for (i=0; i++; i< n){ /*Data Load Phase*/ /*First Data*/ writeToFlash(addressFlow[i],dataFlow[i,0]); /*at the first data of the first page, Quad-EFP may be aborted*/ if (First_Page) { status_register=readFlash(any_address); if (status_register.SR7==1){ /*EFP aborted for an error*/ if (status_register.SR4==1) /*program error*/ error_handler(); if (status_register.SR3==1) /*VPP invalid error*/ error_handler(); if (status_register.SR1==1) /*program to protect block error*/ error_handler(); } } /*2nd data*/ writeToFlash(addressFlow[i],dataFlow[i,1]); /*3rd data*/ writeToFlash(addressFlow[i],dataFlow[i,2]); /*4th data*/ writeToFlash(addressFlow[i],dataFlow[i,3]); /* Program&Verify Phase */ do{ status_register=readFlash(any_address); /* E or G must be toggled*/ }while (status_register.SR0==1) } /* Exit Phase */ writeToFlash(another_block_address,FFFFh); /* status register polling */ do{ status_register=readFlash(any_address); /* E or G must be toggled */ } while (status_register.SR7==0); if (status_register.SR1==1) /*program to protected block error*/ error_handler(); if (status_register.SR3==1) /*VPP invalid error*/ error_handler(); if (status_register.SR4==1) /*program failure error*/ error_handler(); } } 116/123 M58WRxxxKU, M58WRxxxKL Appendix D Table 47. Command interface state tables Command interface state tables Command interface states - modify table, next state(1) Command Input Current CI State Read Array(2) (FFh) Ready Ready Erase Read Clear Confirm, P/E Block DWP, Program/ Read Status Electronic WP EFP Quad-EFP Resume, Erase QWP Erase Status Register signature, setup(3)(4) Setup(3)(4) Setup(3)(4) Setup Setup Block Unlock Read CFI Suspend Register (5) (10/40h) (30h) (75h) confirm, EFP Query (B0h) (70h) (35h, 56h) (20h) Confirm (50h) (90h, 98h) (D0h) Program Setup Lock/CR Setup Program Setup Erase Setup EFP Quad-EFP Setup Setup Ready (Lock Error) Ready Setup OTP Busy OTP Busy IS in OTP busy OTP Busy OTP busy Setup Program Busy Program busy IS in Program busy Program busy Program IS in Program busy Suspend PS IS in Program Suspend Program Busy Ready (error) Erase Busy IS in Erase busy Erase Busy ES Lock/CR Setup in ES Erase Busy Program in ES IS in Erase Suspend Erase Busy Erase Suspend Program Busy in Erase Suspend Program Busy in ES Program IS in Program in ES busy in ES IS in PS in ES ES Erase Suspend Setup Suspend Ready (error) Erase busy IS in ES Busy Program Suspend Erase Busy IS in Erase busy Suspend Program busy Program suspend Setup Erase PS Program Busy IS in PS Busy Ready (Lock Error) OTP Busy IS in OTP busy Busy Ready IS in Program Busy in Erase Suspend Program Busy PS in ES in ES Program Busy in Erase Suspend Program Busy in Erase Suspend PS in ES IS in Program suspend in ES Program Busy in ES Program Suspend in Erase Suspend Program Suspend in Erase Suspend Erase Suspend (Lock Error) ES Erase Suspend (Lock Error) 117/123 Command interface state tables Table 47. M58WRxxxKU, M58WRxxxKL Command interface states - modify table, next state(1) (continued) Command Input Current CI State Setup EFP Quad EFP Read Array(2) (FFh) Erase Read Clear Confirm, P/E Block DWP, Program/ Read Status Electronic WP EFP Quad-EFP Resume, Erase QWP Erase Status Register signature, setup(3)(4) Setup(3)(4) Setup(3)(4) Setup Setup Block Unlock Read CFI Suspend Register (5) (10/40h) (30h) (75h) confirm, EFP Query (B0h) (70h) (35h, 56h) (20h) Confirm (50h) (90h, 98h) (D0h) Ready (error) EFP Busy Busy EFP Busy(6) Verify EFP Verify(6) Setup Quad EFP Busy(6) Busy Quad EFP Busy(6) Ready (error) 1. CI = Command Interface, CR = Configuration Register, EFP = Enhanced Factory Program, Quad EFP = Quadruple Enhanced Factory Program, DWP = Double Word Program, QWP = Quadruple Word Program, P/E. C. = Program/Erase Controller, PS = program suspend, ES = erase suspend, IS = Illegal state. 2. At Power-Up, all banks are in Read Array mode. A Read Array command issued to a busy bank, results in undetermined data output. 3. The two cycle command should be issued to the same bank address. 4. If the P/E.C. is active, both cycles are ignored. 5. The Clear Status Register command clears the Status Register error bits except when the P/E.C. is busy or suspended. 6. EFP and Quad EFP are allowed only when Status Register bit SR0 is set to ‘0’.EFP and Quad EFP are busy if Block Address is first EFP Address. Any other commands are treated as data. 118/123 M58WRxxxKU, M58WRxxxKL Table 48. Command interface state tables Command interface states - Modify table, next output(1) Command Input(2) Current CI State Block Read DWP, QWP Erase Array(3) Setup(4)(5) Setup(4)(5) (FFh) (35h, 56h) (20h) EFP Setup (30h) QuadEFP Setup (75h) Erase Confirm Program/ Read Clear Status Read Electronic P/E Resume, Erase Status Register(6) signature, Read Block Unlock CFI Query (90h, Suspend Register confirm, EFP (50h) 98h) (B0h) (70h) Confirm (D0h) Program Setup Erase Setup OTP Setup Program Setup in Erase Suspend EFP Setup EFP Busy Status Register EFP Verify Quad EFP Setup Quad EFP Busy Lock/CR Setup Lock/CR Setup in Erase Suspend Status Register OTP Busy Ready Program Busy Erase Busy Array Status Register Output Unchanged Program/Erase Suspend Status Register Output Unchanged Electronic Signature/CFI Program Busy in Erase Suspend Program Suspend in Erase Suspend Illegal State Output Unchanged 1. CI = Command Interface, CR = Configuration Register, EFP = Enhanced Factory Program, Quad EFP = Quadruple Enhanced Factory Program, DWP = Double Word Program, QWP = Quadruple Word Program, P/E. C. = Program/Erase Controller, IS = Illegal State, ES = Erase suspend, PS = Program suspend. 2. The output state shows the type of data that appears at the outputs if the bank address is the same as the command address. A bank can be placed in Read Array, Read Status Register, Read Electronic Signature or Read CFI Query mode, depending on the command issued. Each bank remains in its last output state until a new command is issued. The next state does not depend on the bank’s output state. 3. At Power-Up, all banks are in Read Array mode. A Read Array command issued to a busy bank, results in undetermined data output. 4. The two cycle command should be issued to the same bank address. 5. If the P/E.C. is active, both cycles are ignored. 6. The Clear Status Register command clears the Status Register error bits except when the P/E.C. is busy or suspended. 119/123 Command interface state tables Table 49. M58WRxxxKU, M58WRxxxKL Command interface states - Lock table, next state(1) Command Input Current CI State Lock/CR Setup(2) (60h) OTP Setup(2) (C0h) Ready Lock/CR Setup OTP Setup Lock/CR Setup Block Lock Confirm (01h) Busy Ready (Lock error) Ready Ready (Lock error) N/A OTP Busy IS in OTP busy OTP Busy Ready IS Ready Setup Program Busy N/A IS in Program busy Program Busy IS in Program busy Ready Program busy IS in PS IS Ready Program Suspend N/A IS in PS Program Suspend N/A Setup Ready (error) N/A Busy IS in Erase Busy Erase Busy IS in Erase Busy Suspend Lock/CR Setup in ES IS in Erase Suspend N/A Erase Suspend N/A Program Busy in Erase Suspend IS in Program busy in ES Program Busy in Erase Suspend IS in Program busy in ES Suspend IS Ready Erase Suspend Setup Busy Ready Erase Busy IS in ES Program in Erase Suspend N/A OTP Busy Suspend Erase P/E. C. Operation Completed IS in OTP busy Busy Program Illegal Command(4) Ready Setup OTP Block Lock- Set CR EFP Exit, Down Confirm Quad EFP Confirm (2Fh) (03h) Exit(3) ES Program busy in ES IS in PS in ES IS in ES Program Suspend in Erase Suspend N/A IS in PS in ES Lock/CR Setup in ES Program Suspend in Erase Suspend Erase Suspend (Lock error) Erase Suspend Setup EFP Erase Suspend (Lock error) Ready (error) (5) Busy EFP Busy Verify EFP Verify(5) N/A EFP Verify EFP Busy Ready EFP Verify(5) Ready Quad EFP Busy(4) Quad EFP Busy(5) N/A Ready N/A QuadEFP Busy (5) Quad EFP Busy(5) Setup N/A Ready 1. CI = Command Interface, CR = Configuration Register, EFP = Enhanced Factory Program, Quad EFP = Quadruple Enhanced Factory Program, P/E. C. = Program/Erase Controller, IS = Illegal state, ES = Erase suspend, PS = Program suspend. 2. If the P/E.C. is active, both cycles are ignored. 3. EFP and Quad EFP exit when Block Address is different from first Block Address and data is FFFFh. 4. Illegal commands are those not defined in the command set. 5. EFP and Quad EFP are allowed only when Status Register bit SR0 is set to ‘0’. EFP and Quad EFP are busy if Block Address is first EFP Address. Any other commands are treated as data. 120/123 M58WRxxxKU, M58WRxxxKL Table 50. Command interface state tables Command interface states - Lock table, next output(1) Command Input Current CI State Lock/CR Setup(2) (60h) OTP Setup(2) (C0h) Block Lock Confirm (01h) Block LockDown Confirm (2Fh) Set CR Confirm (03h) EFP Exit, Quad EFP Exit(3) Illegal Command(4) P/E. C. Operation Completed Program Setup Erase Setup OTP Setup Program Setup in Erase Suspend Status Register EFP Setup EFP Busy EFP Verify Quad EFP Setup Quad EFP Busy Output Unchanged Lock/CR Setup Status Register Lock/CR Setup in Erase Suspend Array Status Register OTP Busy Ready Program Busy Erase Busy Status Register Output Unchanged Array Program/Erase Suspend Output Unchanged Program Busy in Erase Suspend Program Suspend in Erase Suspend Illegal State Output Unchanged 1. CI = Command Interface, CR = Configuration Register, EFP = Enhanced Factory Program, Quad EFP = Quadruple Enhanced Factory Program, P/E. C. = Program/Erase Controller. 2. If the P/E.C. is active, both cycles are ignored. 3. EFP and Quad EFP exit when Block Address is different from first Block Address and data is FFFFh. 4. Illegal commands are those not defined in the command set. 121/123 Revision history M58WRxxxKU, M58WRxxxKL Revision history Table 51. Document revision history Date Version Changes 0.1 Initial release. M58WR032KU/L (revision 0.2 of 21-Jul-2006) and M58WR064KU/L (revision 0.1 of 21-Sep-2006) datasheets merged. M58WR016KU and M58WR016KL part numbers added. Changes made: Document status promoted from Target Specification to Preliminary Data. 60 ns speed class and 86 MHz frequency added. During Erase Suspend, the Set Configuration Register command is also accepted (see Program/Erase Suspend command and Figure 23: Program Suspend & Resume flowchart and pseudocode). VDDQ max modified in Table 19: Absolute maximum ratings. VPPLK max modified in Table 23: DC characteristics - voltages. Data and Values modified at address offsets 1Dh and 1Eh in Table 39: CFI query system interface information. Value modified at address offset (P+D)h = 46h in Table 41: Primary algorithm-specific extended query table. Data modified at address offsets (P+2E)h = 67h, (P+30)h = 69h and (P+31)h = 6Ah in Table 46: Bank and Erase block region 2 information. Appendix D: Command interface state tables updated. 0.2 Parameter Block, Main Block and Bank Program values modified for VPP = VPPH in Table 18: Program, erase times and endurance cycles. VRPH removed from Table 23: DC characteristics - voltages. tELTV, tEHTZ, tEHQZ, tGHQZ, tAVLH, tELLH, tLHAX, tLHGL modified for 60 ns speed class in Table 24: Asynchronous Read ac characteristics. tAVKH, tELKH, tELTV, tEHEL, tGHTV, tGHTL, tKHAX, tKHQX, tKHTX, tLLKH modified for 60 ns speed class in Table 25: Synchronous Read ac characteristics. tVDHPH modified in Table 28: Reset and Power-up ac characteristics. Data modified at address offset (P+D)h = 46h in Table 41: Primary algorithm-specific extended query table. Small text changes. 16-Jan-2007 0.3 Small text changes. Section 5.8: Program/Erase Suspend command and Figure 25: Erase Suspend & Resume flowchart and pseudocode) updated. IDD5 values when VPP = VDD and IDD6 values modified in Table 22: DC characteristics - currents. Note 1 added below Table 41, Note 1 added below Table 42 and Note 1 added below Table 43. tAVLH min, tELLH min, tLHAX min, tLHGL min and max values modified in Table 26: Write ac characteristics, Write Enable controlled and Table 27: Write ac characteristics, Chip Enable controlled. 25-May-2007 1 Document status promoted from Preliminary Data to full Datasheet. IDD1, IDD5 and IDD6 changed in Table 22.: DC characteristics - currents. Data modified in Table 46.: Bank and Erase block region 2 information. 3-Dec-2007 2 Applied Numonyx branding. 06-Nov-2006 05-Jan-2007 122/123 M58WRxxxKU, M58WRxxxKL Please Read Carefully: INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH NUMONYX™ PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN NUMONYX'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, NUMONYX ASSUMES NO LIABILITY WHATSOEVER, AND NUMONYX DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF NUMONYX PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. Numonyx products are not intended for use in medical, life saving, life sustaining, critical control or safety systems, or in nuclear facility applications. Numonyx may make changes to specifications and product descriptions at any time, without notice. Numonyx, B.V. may have patents or pending patent applications, trademarks, copyrights, or other intellectual property rights that relate to the presented subject matter. The furnishing of documents and other materials and information does not provide any license, express or implied, by estoppel or otherwise, to any such patents, trademarks, copyrights, or other intellectual property rights. Designers must not rely on the absence or characteristics of any features or instructions marked “reserved” or “undefined.” Numonyx reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. Contact your local Numonyx sales office or your distributor to obtain the latest specifications and before placing your product order. Copies of documents which have an order number and are referenced in this document, or other Numonyx literature may be obtained by visiting Numonyx's website at http://www.numonyx.com. Numonyx StrataFlash is a trademark or registered trademark of Numonyx or its subsidiaries in the United States and other countries. *Other names and brands may be claimed as the property of others. Copyright © 11/5/7, Numonyx, B.V., All Rights Reserved. 123/123