Teledyne DRL48A35 Single output to 35a 510 vac din-rail solid-state relay Datasheet

NEW Series DRL
Single Output to 35A 510 Vac
DIN-Rail Solid-State Relay
Part Number
Description
DRL48R35
35A 510 Vac Output
DRL48D35-21
35A 480 Vac Output
DRL48D35
35A 510 Vac Output
DRL48A35-22
35A 510 Vac Output
DRL48A35
35A 510 Vac Output
Part Number Explanation
DRL
48
D
35
-21
NOTES
1) Line Voltage (nominal): 48 = 480 Vac
2) Switch Type: D = Zero-cross turn-on; A = Zero-cross, AC control;
R = Random turn-on
3) Features: -21 = Self turn-on suppression; -22 = 24 Vac control
MECHANICAL SPECIFICATION
FEATURES/BENEFITS
• Mounting and dismounting on DIN rail without
any tool or directly mountable on panel
• Zero-cross and random models; thyristors output
• Large control range
• Green control LED
• Very high immunity
• Low leakage current
• Internal transient suppression
DESCRIPTION
The Series DRL single-phase DIN-rail relays are
designed for all types of loads. The relays utilize
optical isolation to protect the control from load
transients. DRL relays have an integral heat sink, and
can be mounted and dismounted onto a DIN rail
without any tools. The relays may also be panel
mounted. All relays offer a green control LED and
transient suppression.
APPLICATIONS
• Heating control
• Motor control
• Industrial and process control
APPROVALS
Series DRL relays are pending UL recognition.
Figure 1 — DRL relay; dimensions in inches (mm)
© 2003 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
DRL 1
DRL\032003\Q1
Series DRL
INPUT (CONTROL) SPECIFICATION
CONTROL CHARACTERISTIC
12
Min
Max
Units
3.5
32
Vdc
Control Current (mA)
Control Range
10
DRL48R35
8
DRL48D35-21
6
DRL48D35
4
3
32
Vdc
3.5
32
Vdc
DRL48A35-22
17
60
Vac/Vdc
DRL48A35
150
240
Vac/Vdc
DRL48R35
10
mAdc
DRL48D
10
mAdc
2
Control Current Range
0
0
2
4
6
8 10 12 14 16 18 20 22 24 26 28 30 32
Control Voltage (V)
Figure 2a — DR38R and DR48D relays
DRL48A35-22
3
20
mA
DRL48A35
3
7
mA
Control Current (mA)
20
Must Turn-off Voltage
15
10
5
DRL48R35
2
V
DRL48D35-21
1
V
DRL48D35
2
V
DRL48A35-22
4
V
DRL48A35
15
V
0
0
10
20
30
40
50
60
Control Voltage (V)
Figure 2b — DRL48A35-22 relay
Reverse Voltage (DC Control)
32
V
Clamping Voltage (DC Control)
42
V
Input LED
Green
Control Current (mA)
8
TYPICAL APPLICATION
6
400 Vac 60Hz
400 Vac 60Hz
4
Protection
Protection
2
L1
L1
SSR
SSR
0
0
50
100
150
200
250
Control Voltage (V)
T1
T1
A2 A1
Figure 2c — DRL48A35 relay
A2 A1
Control
– +
Control
Load
Load
Figure 3 — DRL relay DC control (left) and DRL relay
AC control (right)
DRL 2
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2003 TELEDYNE RELAYS
DRL\032003\Q1
Series DRL
OUTPUT (LOAD) SPECIFICATION
Min
Operating Range
Max
24
Peak Voltage
ENVIRONMENTAL SPECIFICATION
Unit
Min
Max
Unit
510
Vrms
Storage Temperature
–30
100
°C
1200
Vpeak
Operating Temperature
–30
80
°C
Clamping Voltage
Input-Output Isolation
4000
Vrms
Output-Case Isolation
4000
Vrms
-21 feature (On voltage, typical)
950
V
Insulation Resistance
100
MΩ
All others (@1mA)
820
V
Rated Impulse Voltage
4000
V
Zero-Cross Window (Typical)
THERMAL CHARACTERISTICS
Random
DRL48D35-21
±10
V
DRL48D35
±20
V
DRL48A
±20
V
Non-Repetitive Surge Current
(See Figure 5)
550
On-State Voltage Drop (Typical)
A
0.9 V
45
40
Load Current (Arms)
DRL48R35
Output Power Dissipation
(Typical)
35
30
25
20
15
10
5
0.81xIe+0.08xIe2
0
0
Thermal Resistance
(Junction to Air)
5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (°C)
2.6
°C/W
1
mA
Figure 4 — DRL relays
0.1
ms
SURGE CURRENTS
DRL48D
8.3
ms
DRL48A
24.9
ms
Off-State Leakage Current (60Hz)
Turn-On Time (60Hz)
DRL48R35
600
Non-Repetitive
Apeak
400
Turn-Off Time (60Hz)
DRL48R35
8.3
ms
DRL48D
8.3
ms
DRL48A
24.9
ms
Operating Frequency Range 0.1
440
Hz
Off-State dv/dt
500
V/µs
1500
A2S
200
Repetitive with initial Tj = 70˚C
0
0.01
0.1
1
10
t (s)
Figure 5 — DRL relays
2
I t for match fusing (<8.3ms)
© 2003 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
DRL 3
DRL\032003\Q1
Series DRL
DIN-RAIL MOUNTING
Mounting
Recommended to connect
DIN rail to ground.
Dismounting
Figure 6 — DRL relays
PANEL MOUNTING
M4
Drill for vertical can be adjusted
M5
3.47±.08
(88±2)
.5 (12.7)
Figure 7 — DRL relays
CONNECTIONS
L
wires
L
torques
screwdriver
(mm2)
control
NOTES:
1. Connections: For output terminals, the wire cross-sections must be
adapted to the load current and to the overcurrent protection device
characteristics. The relay rated voltage must be adapted to the mains
rated voltage. These relays use screw clamp connections.
2. Mounting: Only in vertical position.
Protect heat-sensitive materials as well
as people from contact with the heat
sink. For non-vertical mounting, the load
current must be derated by 50%. The
SSR requires air convection. Lack of air
convection produces an abnormal
heating. Keep a distance between the
upper SSR and the lower SSR (see
vertical
3.15 inches
position
(80mm)
figure on the right). In case of zero space
between two SSRs, reduce the load
current. It’s suggested to maintain the
heat sink temperature under 90°C.
Forced cooling significantly improves the
thermal performances.
3. Typical application loads: The DRL relay
may handle motor and resistive loads.
For different loads, check the inrush current at turn-ON and possible
overvoltages at turn-OFF or contact the factory.
• Incandescent lamps — Inrush current is generally 10 times the
nominal current for 10ms.
• Electric discharge lamp — These loads often have overcurrent at
turn-ON and overvoltage at turn-OFF. Use 480Vac SSR on 240Vac
mains.
• Transformer loads — Very high inrush current, up to 100 times the
nominal current.
• Capacitive loads — Very high current at turn-ON and overvoltage
at turn-OFF. Use only zero-cross models.
4. Protection: To protect the SSR against a
1~
short-circuit of the load, use a fuse with a I2t
Fuse
2
value = 1/2 I t value.
5. EMC:
Immunity: lmmunity levels of the DRL comply
L1
with EN61000-4-4 &5.
Emission: The system integrator must ensure
that systems containing SSRs comply with the
requirements of any rules and regulations
applicable at the system level. The very low
T1
zero-cross voltage (<20V) improves the
conducted emission level in comparison with
A1 +
control
most SSRs with zero-cross voltage higher
A2
Load
–
than 50V.
6. All electrical parameters specified at 25°C
unless otherwise noted.
N
1 x (0.75-->2.5)
L = 6mm
0.4N.m
(0.6N.m max)
3.5 x 0.5mm
1.2N.m
(1.8N.m max)
Pozidriv2/
0.8 x 5.5 (1 x 6)
Power
1 x (1.5-->16) 1 x (1.5-->10)
L = 10mm
Figure 8 — DRL relays
DRL 4
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2003 TELEDYNE RELAYS
DRL\032003\Q1