Specification for Approval ( Ver 1.0 ) Part No. : LWM1037N comments LUXPIA Co., Ltd. Designed by Checked by Approved by / / / / . Date : Date : . . 948-1, Dunsan-Li Bongdong-Eup, Wanju-Gun, JeonBuk, Korea Approved by Approved by Approved by / . Tel 82-70-8671-2500 / . . LUXPIA CO.,LTD. Fax 82-70-8620-8081 - CONTENTS - 1. Features 2. Package Outline Dimensions and Materials 3. Absolute Maximum Ratings 4. Electro-Optical Characteristics 5. CIE Chromaticity Diagram 6. Materials 7. Taping 8. Packing 9. Reliability 10. Cautions 11. Warranty 12. Characteristic Diagrams (Ver 1.0) 1/20 1. Features • Package : SMD Top View Type (1chip, 1Zener in 1PKG) • Dimension : 3.5 × 2.8 × 0.8 mm (L×W×H) • Small size surface mount type • Viewing angle : extremely wide(120˚) • Soldering methods : IR reflow soldering 2. Package Outline Dimensions and Recommended Solder Patterns (units : mm) (Ver 1.0) 2/20 3. Absolute Maximum Ratings (Ta=25℃) Iem Smbol Vlue Unit Forward Current IF 60 mA IFP 150 mA Reverse Voltage VR 5 V Power Dissipation PD 200 mW Operating Temperature Topr -30 to+85 ℃ Storage Temperature Tstg -40 to +100 ℃ Pulse Forward Current 1) 1) IFP conditions : pulse width ≤ 10msec & duty ratio ≤ 1/10 4. Electro-Optical Characteristics (Ta=25℃) Item Rank Forward voltage 3) Luminous intensity 4) Min Typ Max V28 2.8 - 2.9 V29 2.9 - 3.0 3.0 - 3.1 V31 3.1 - 3.2 V32 3.2 - 3.3 3E60 6.0 - 6.5 6.5 - 7.0 7.0 - 7.5 7.5 - 8.0 - - 150 V30 3E65 3E70 Symbol VF IV Condition IF= 60mA IF= 60mA 3E75 Reverse current - IR VR= 5V Unit 2) Forward voltages are tested at a current pulse duration of 10 ms and an accuracy within ±0.1V. 3) Dominant wavelength are tested at a current pulse duration of 10 ms and an accuracy within ±1nm. 4) The allowance of luminous intensity measurement is within ±10%. * To avoid optical difference, please do not mix differently ranked product. * All measurements were made under the standardized environment of LUXPIA. (Ver 1.0) 3/20 V cd uA 5. CIE Chromaticity Diagram 5) ( Ta=25℃, IF=20mA) (Ver 1.0) 4/20 ( Ta=25℃, IF=20mA) (Ver 1.0) 5/20 ( Ta=25℃, IF=20mA) (Ver 1.0) 6/20 ( Ta=25℃, IF=20mA) (Ver 1.0) 7/20 ( Ta=25℃, IF=20mA) 5) The allowance of color coordinates measurement is within ±0.01. (CIE1931 standard colorimetric system) (Ver 1.0) 8/20 6. Materials Item Material LED chip InGaN Wire Gold Lead Frame Copper Alloy/Ni/Ag Plating Encapsulation Silicone Heat-Resistant Polymer PPA 7. Taping 7.1. Tape (Material : PS conductive, 104~105Ω) (units : mm) Cathode Anode (Ver 1.0) 9/20 7.2. Wheel (Color : Black, Material : PS conductive, 109~1012Ω) (units : mm) - Quantity Per Reel LWM1035N : 3,000pcs 7.3. Label part no. size (L X W) : 85mm × 50mm LWM1037N C4 – 3E70 – V30 2,000ea Color rank (Ver 1.0) IV rank VF rank 10/20 8. Packing • The LEDs are packed in cardboard boxes after taping. The label shows part number, lot number, rank, and quantity. • In order to protect the LEDs from mechanical shock, they are packed with cardboard boxes for transportation. • The LEDs may be damaged if the boxes are dropped or receive a strong impact against them, so cautions must be taken to prevent any possible damage. • The boxes are not water-resistant and, therefore, must be kept away from water and moisture. • When the LEDs are transported, it is recommended that the same packing method as Luxpia's is used. • If noticeable damage on a box appears upon arrival at the user’s warehouse, the user should submit a claim to Luxpia within one week after arrival of the products. (Ver 1.0) 11/20 9. Reliability 8.1. Test Items And Results Standard No. Test Item Number Of Test Conditions Test Note Damaged Method Sample o Tsld=260 C, 10sec Resistance to Soldering 1 Heat (pre treatment JESD22-B106 3 Solderability EIAJED4701-200 (reflow) JESD22-B102 Temperature Cycle 4 5 6 7 8 EIAJED4701-100 JESD22-A104 EIAJED4701-200 Storage JESD22-A103 High Humidity and EIAJED4701-200 Temperature Storage JESD22-A101 Low Temperature EIAJED4701-200 Storage JESD22-A103 Steady-state Operating MIL-STD-883E Lifetime Test JESD22-A108 Lifetime of High Temperature MIL-STD-883E JESD22-A108 1 time Tsld=215±5oC, 3sec 0/45 over 95% -40oC through +25oC to +100℃ 100 cycles 0/45 Ta=100℃ 1000 hrs 0/45 Ta=60℃, RH=90% 1000 hrs 0/45 Ta=-40℃ 1000 hrs 0/45 Ta=25℃, IF=60mA 500 hrs 0/45 Ta=85℃, IF=7.5mA 1000 hrs 0/45 500 hrs 0/45 1000 hrs 0/45 (30min/5min/30min) High Temperature Steady-state Operating 0/45 60 C,90%,24hrs) (Reflow) 2 2 times o Steady-state Operating Lifetime of High 9 Ta=60℃, RH=90%, - Humidity and IF=20mA Temperature Steady-state Operating 10 Lifetime of Low Temperature MIL-STD-810F JESD22-A108 Ta=-30℃, IF=20mA * LED with Luxpia standard circuit board 8.2. Criteria for Judging the Damage Item Symbol Test Condition Forward Voltage VF Luminous Intensity IV 5) U.S.L. : Upper Standard Level 6) L.S.L. : lower standard level (Ver 1.0) Criteria for Judgment Min Max IF = 60mA - U.S.L.5) × 1.1 IF = 60mA L.S.L.6) × 0.7 - 12/20 10. Cautions The LEDs are device which are materialized by combining Blue LEDs and special phosphors. Consequently, the color of White LEDs is subject to change a little by an operating current. Care should be taken after due consideration when using LEDs. (1) Moisture-Proof Package • When moisture is absorbed into the SMT package it may vaporize and expand products during soldering. There is a possibility that this may cause exfoliation of the contacts and damage to the optical characteristics of the LEDs. For this reason, the moisture-proof package is used to keep moisture to a minimum in the package. • A package of a moisture-absorbent material (silica gel) is inserted into the shielding bag. The silica gel changes its color from blue to pink as it absorbs moisture. (2) Storage • Storage Conditions - Before opening the package : The LEDs should be kept at 5℃~30℃ or less and 65%RH or less. The LEDs should be used within a year. When storing the LEDs, moisture-proof packaging with moisture-absorbent material (silica gel) is recommended. - After opening the package : The LEDs should be kept at 5℃~40℃ or less and 30%RH or less. The LEDs should be soldered within 168 hours (7 days) after opening the package. If unused LEDs remain, they should be stored in moisture-proof packages, such as sealed containers with packages of moisture-absorbent material (silica gel). It is also recommended to return the LEDs to the original moisture-proof bag and to reseal the moisture-proof bag again. • If the moisture-absorbent material (silica gel) has faded away or the LEDs have exceeded the recommended storage time, baking treatment should be performed using the following conditions. - Baking treatment : more than 24 hours at 65±5℃ • After assembly and during use, silver plating can be affected by the corrosive gases emitted by components and materials in close proximity of the LEDs within an end product, and the gases entering into the product from the external atmosphere. The above should be taken into consideration when designing. • Please avoid rapid transitions in ambient temperature, especially in high humidity environments where condensation can occur. (3) Heat Generation • Thermal design of the end product is of paramount importance. Please consider the heat generation of the LED when the system is designed. The coefficient of temperature increase per input electric power is affected by the thermal resistance of the circuit board and density of LED placement on the board, as well as other components. It is necessary to avoid intense heat generation and operate within the maximum ratings given in the specification. • The operating current should be decided after considering the ambient maximum temperature of LEDs. (Ver 1.0) 13/20 (4) Recommended circuit • In designing a circuit, the current though each LED must not exceed its absolute maximum rating. It is recommended to use Circuit B which regulates the current flowing through each LED. In the meanwhile, when driving LEDs with a constant voltage in Circuit A, the current through the LEDs may vary due to the variation in forward (VF) of the LEDs. In worst case, some LED may be subjected to stresses in excess of the absolute maximum rating. • This product should be operated in forward bias. Driving circuit must be designed so that the product is not subjected to either forward or reverse voltage while it is off. In particular, if a reverse voltage is continuously applied to the product, such operation can cause migration resulting in LED damage. • Please determine the operating current with consideration of the ambient temperature local to the LED and refer to the plot of Ambient temperature vs. Allowable Forward Current on CHARACTERISTICS in this specifications. Please also take measures to remove heat from the area near the LED to improve the operational characteristics of the LED. (5) Handling Precautions • Bare Hand When handling the product, touching encapsulant with bare hands will contaminate its surface that could affects optical characteristics. In the worst cases, excessive force the encapsulant by hands might result in catastrophic failure of the LEDs due to wire deformation and/or breakage. • Tweezers Since silicone used as encapsulating resin in this product is a soft material, the upper surface of the product is soft. Pressuring onto the product might cause catastrophic failure of the LEDs due to damage to encapsulant (such as scratch, chip-out and delamination) and wire (such as deformation and breakage) and LED detachment. (Ver 1.0) 14/20 • Pick and Place Recommended conditions: Outer nozzle≥Φ2.4mm ※ Avoid direct contact to the encapsulant with the picking nozzle. Failure to comply might result in damage to encapsulant and in the worst cases, catastrophic failure of the LEDs due to wire deformation and/or breakage. • Drop Please note that a package damage such as crack might occur when having dropped the product. (Ver 1.0) 15/20 • Printed Circuit Board Assembled (PCB with LEDs soldered) Do not stack assembled PCBs together. Since silicone is a soft material abrasion between two PCB assembled with encapsulate LED might cause catastrophic failure of the LEDs due to damage to encapsulant (such as scratch, chip-out and delamination) and wire (such as deformation and breakage) and LED detachment. (6) Soldering Conditions • The LEDs can be soldered in place using the reflow soldering method. Luxpia does not make any guarantee on the LEDs after they have been assembled using the dip soldering method. • Recommended soldering conditions Reflow Soldering Hand Soldering Lead Solder Lead-free Solder Pre-Heat 120~150℃ 180~200℃ Pre-Heat Time 120sec Max. 120sec Max. Temperature Peak Temperature 240℃ Max. 260℃ Max. Soldering Time Soldering Time Condition 10sec Max. 10sec Max. refer to profile ① refer to profile ② 350℃ Max. 3sec Max. (one time only) * Although the recommended soldering conditions are specified in the above table, reflow soldering at the lowest possible temperature is desirable for the LEDs. * A rapid-rate process is not recommended for cooling the LEDs down from the peak temperature. [Temperature-Profile (surface of circuit board)] Use the conditions shown to the following figures. <① : Lead Solder> <② : Lead-free Solder> • Occasionally there is a brightness decrease caused by the influence of heat or ambient atmosphere during (Ver 1.0) 16/20 air reflow. It is recommended that the User use the nitrogen reflow method. • Repairing should not be done after the LEDs have been soldered. When repairing is unavoidable, a doublehead soldering iron should be used. It should be confirmed beforehand whether the characteristics of the LEDs will or will not be damaged by repairing. • Reflow soldering should not be done more than two times. • When soldering, do not put stress on the LEDs during heating. • After soldering, do not warp the circuit board. (7) Cleaning • It is recommended that isopropyl alcohol be used as a solvent for cleaning the LEDs. When using other solvents, it should be confirmed beforehand whether the solvents will dissolve the package and the resin or not. Freon solvents should not be used to clean the LEDs because of worldwide regulations. Do not clean the LEDs by the ultrasonic. When it is absolutely necessary, the influence of ultrasonic cleaning on the LEDs depends on factors such as ultrasonic power and the assembled condition. Before cleaning, a pre-test should be done to confirm whether any damage to the LEDs will occur. (8) Static Electricity • Static electricity or surge voltage damages the LEDs. It is recommended that a wrist band or an antielectrostatic glove be used when handling the LEDs. • All devices, equipment and machinery must be properly grounded. It is recommended that measurements be taken against surge voltage to the equipment that mounts the LEDs. • When inspecting the final products in which LEDs were assembled, it is recommended to check whether the assembled LEDs are damaged by static electricity or not. It is easy to find static-damaged LEDs by a light-on test or a VF test at a lower current (below 1mA is recommended). • Damaged LEDs will show some unusual characteristics such as the leak current remarkably increases, the forward voltage becomes lower, or the LEDs do not light at the low current. - criteria : VF > 2.0V at IF=0.5㎃ (9) Others • This LED complies with RoHS Directive. • The LED light output is strong enough to injure human eyes. Precautions must be taken to prevent looking directly at the LEDs with unaided eyes for more than a few seconds. • Flashing lights have been known to cause discomfort in people; you can prevent this by taking precautions during use. Also, people should be cautious when using equipment that has had LEDs incorporated into it. • The customer not reverse engineer by disassembling or analysis of the LEDs without having prior written consent from Luxpia. When defective LEDs are found, the User shall inform Luxpia directly before disassembling or analysis. • The warranties of quality set forth herein are exclusive. All previous negotiations and agreements not specifically incorporated herein are superseded and rendered null and void. • Both parties shall sincerely try to find a solution when any disagreement occurs regarding these specifications. • These specifications can be revised upon mutual agreement. • Luxpia understands that the User accepts the content of these specifications, if the User does not return these specifications with signatures within 3 weeks after receipt. • The LEDs described in the specification are intended to be used for ordinary electronic equipment (such as office equipment, communications equipment, on the applications in which exceptional quality and reliability are required, particularly when the failure or malfunction of the LEDs may directly jeopardize life or health (such as for airplanes, aerospace, submersible repeaters, nuclear reactor control systems, automobiles, traffic control equipment, life support systems and safety devices) (Ver 1.0) 17/20 11. Warranty (1) Luxpia warrants that its LEDs conform to the foregoing specifications and that Luxpia will convey good title to all LEDs sold. (2) LUXPIA disclaims all other warranties including the implied warranties of merchantability and fitness for a particular purpose. (3) In the event any LED supplied by Luxpia is found not to conform to the foregoing specifications within ninety days of receipt, Luxpia will repair or replace the LED, at Luxpia’s discretion, provided that the User (a) promptly notifies Luxpia in writing of the details of the defect (b) ships the LEDs at the User’s expense to Luxpia for examination, and (c) the defect is due to the negligence of Luxpia and not mishandling or misuse by the User. (4) Luxpia will not take responsibility for any trouble that is caused by using the LEDs at conditions exceeding our specifications. (5) These specifications are applied only when a LED stands alone and it is strongly recommended that the User of the LEDs confirms the properties upon assembly. Luxpia is not responsible for failures caused during and after assembling. It will be excepted from the rule if the failure would caused undoubtedly by Luxpia. (6) A claim report stating details about the defect shall be made when returning defective LEDs. Luxpia will investigate the report immediately and inform the user of the results. (7) LUXPIA’s liability for defective lamps shall be limited to replacement and in no event shall LUXPIA be liable for consequential damage or lost profits. (Ver 1.0) 18/20 12. Characteristic Diagrams (1) Forward Voltage vs. Forward Current (2) Forward Current vs. Relative Luminosity (Ta=25℃) (Ta=25℃) 3.0 2.5 Relative Luminosity [a.u.] Forward Current IF [mA] 180 150 120 90 60 30 2.0 1.5 1.0 0.5 0 1 1.5 2.0 2.5 3.0 4.0 3.5 30 0 Forward Voltage VF[V] 90 120 150 Forward Current IF[mA] (4) Ambient Temperature vs. Relative Luminosity (3) Ambient Temperature vs. Allowable Forward Current (IF=60mA) 120 10 100 Relative Luminosity[a.u.] Allowable Forward Current IA[mA] 60 80 60 40 1 20 -20 0 20 40 60 80 0.1 -40 100 0 20 40 60 Ambient Temperature Ta[℃] Ambient Temperature Ta[℃] (Ver 1.0) -20 19/20 80 100 (7) Relative Spectral Emission V(λ) = Standard Eye Response Curve (Ta=25℃, IF=60mA) (8) Radiation Characteristics (Ta=25℃, IF=60mA) Relative Luminous Intensity Iv[%] (Ver 1.0) 20/20