Vitec ILPA40JUD-S105DS 40w dimmable water-proof constant current led driver Datasheet

ILPA40JUD SERIES
40W Dimmable Water-Proof Constant Current LED Driver
–
–
–
–
–
–
–
2 Year Warranty
Wide Input Voltage 90 to 305VAC, 47 to 63Hz
Constant Output Current Available From 350mA To 3330mA
Over Voltage, Short Circuit, Over Load Protection
High Efficiency (up to 88%)
Active Power Factor Correction (PFC) (92% typical)
IP66 Waterproof Rating
Comply with UL8750 & EN61347 Safety Regulation (Pending)
Approvals: (Pending)
Single Output
Part Number
ILPA40JUD-S333DS
ILPA40JUD-S222DS
ILPA40JUD-S166DS
ILPA40JUD-S140DS
ILPA40JUD-S128DS
ILPA40JUD-S105DS
ILPA40JUD-S070DS
ILPA40JUD-S045DS
ILPA40JUD-S035DS
Output Current Range
(Min. / Typ. / Max.)
3164 / 3330 / 3497 mA
2109 / 2220 / 2331 mA
1577 / 1660 / 1743 mA
1330 / 1400 / 1470 mA
1216 / 1280 / 1344 mA
998 / 1050 / 1103 mA
665 / 700 / 735 mA
428 / 450 / 473 mA
333 / 350 / 368 mA
Output Voltage
(Min. / Max.)
4 / 12 VDC
6 / 18 VDC
8 / 24 VDC
10 / 29 VDC
11 / 31 VDC
12 / 36 VDC
18 / 54 VDC
30 / 89 VDC
38 / 114 VDC
Efficiency
(220VAC, Full Load)
84%
85%
86%
87%
87%
87%
87%
88%
88%
Over Voltage Protection
(Min. / Typ. / Max.)
13 / 15 / 17 VDC
22 / 24 / 26 VDC
30 / 32 / 34 VDC
36 / 38 / 40 VDC
41 / 43 / 45 VDC
46 / 48 / 50 VDC
68 / 70 / 72 VDC
114 / 116 / 118 VDC
146 / 148 / 150 VDC
Max.
Output Power
35W
36W
38W
36W
38W
38W
38W
40W
40W
Electrical Characteristics
Parameter
Input Voltage
Input Frequency
Output Power Range
Input Current (Low Line)
Input Current (High Line)
High Line Inrush Current
Power Factor Correction
Efficiency
No Load Power Dissipation
Line Regulation
Load Regulation
Over Voltage Protection
Over Load Protection
Short Circuit Protection
Output Overshoot / Undershoot
Start Up Time
Ripple & Noise (Peak to Peak)
Test Conditions
Operating Voltage
Vin=90 to 305VAC
Io=Full load, Vin=115VAC
Io=Full load, Vin=230VAC
Io=Full load, 25°C, Cool start, Vin=230VAC
Vin=110VAC
Min.
90
47
0
Typ.
Max.
305
63
40
0.48
0.23
20
99
Unit
VAC
Hz
W
A
A
A
%
Io=Full Load, Vin=220VAC
88
%
3
W
Io=Full Load
2
%
Vin=230VAC
5
%
Latch mode. The power unit shall return to normal operation only after the power is turn-on again.
(Please refer to output table.)
Hiccup mode. The power supply shall be self-recovery
1.25
Po
when the fault condition is removed.
No damage shall occur when any output operating in a short circuit condition. The power supply shall be
self-recovery when the fault condition is removed.
When power on or off
10
%
Io=Full Load, Vin=100VAC
1.7
2
S
Measured by 20 MHz bandwidth oscilloscope and the
output paralleled a 0.1 uF ceramic capacitor and a 10
uF electrolytic capacitor.
5
% Vo
Conditions
Parameter
Test Conditions
Min.
Operating Temperature
Humidity: 10% RH to 100% RH
Storage Temperature
Humidity: 5% RH to 100% RH
MTBF: Operation temperature at 25°C, calculated per MIL-HDBK-217F
Life Time at 25°C ambient temperature
Typ.
-20
-40
0.487M
0.077M
Max.
Unit
70
85
°C
°C
Hours
Hours
Approvals and Compliance
Parameter
EMI
EMS
Safety UL/c-UL, CE
Waterproof
Standards
EN55015
EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, , EN61000-4-4, , EN61000-4-5, EN61000-4-6,
EN61000-4-8, EN61000-4-11, EN61547
(Pending) UL8750 Compliant to UL1310 ClaST 2, UL1012, UL935, CSA-C22.2 No. 0, CSA-C22.2 No. 107.1,
CSA-C22.2 No.250.0, EN61347-1,EN61347-2-13
IP66 Rating
Mechanical
Parameter
Specification
Dimension,
78x80x25mm (3.07x3.15x0.98 inches)
Net Weight
200g approx.
Dimming Control
Parameter
Min.
Typ.
Max.
Unit
10V Output Voltage
9.8
10V
10.2
VDC
10V Output Source Current
-10
2
mA
Absolute Max. Voltage on the 1~10V Input Pin
-2
15
VDC
Source Current on 0-10V Input Pin
0
1
mA
The dimmer control may be operated from either a potentiometer or from an input signal of 0 ~ 10 Vdc. Two recommended implementations are provided
above
Notes:
1. For the driver to operate properly, the load voltage must be maintained above the minimum voltage threshold (approx. 33% of t he max. output
voltage for any given model).
2. If the output voltage is maintained above 50% of the maximum output voltage, the dimmer control may be operated over the entire 0-10V
range with output current varying from 100% down to practically 0%.
3. If the output voltage is maintained between 33-50% of the maximum output voltage, the dimmer control may be operated over 5-10V range
with output current
Similar pages