RECOM REC10

Features
Regulated
Converters
●
●
●
●
●
●
●
●
ECONOLINE
10W 1”x 2” Package (50.8x25.4x11.27mm)
1kVDC Isolation
Wide Input 2:1 & 4:1
Regulated Output
UL94V-0 Package Material
Continuous Short Circuit Protection
Remote ON/OFF-Control for Single Types
Efficiency to 82%
DC/DC-Converter
REC10S_DRWL(Z)
Series
Selection Guide
Part
Number
1” x 2”
Input
Output
Output
Voltage
Voltage
Current
Efficiency
(VDC)
(VDC)
(mA)
(%)
REC10-xx05SRWL
9-18, 18-36, 36-72
5
2.000
78
REC10-xx12SRWL
9-18, 18-36, 36-72
12
830
81
REC10-xx15SRWL
9-18, 18-36, 36-72
15
670
81
REC10-xx24SRWL
9-18, 18-36, 36-72
24
416
82
REC10-xx05DRWL
9-18, 18-36, 36-72
±5
±1.000
78
REC10-xx12DRWL
9-18, 18-36, 36-72
±12
±416
81
REC10-xx15DRWL
9-18, 18-36, 36-72
±15
±333
82
REC10-xx05SRWLZ
9-36, 18-72
5
2.000
79
REC10-xx12SRWLZ
9-36, 18-72
12
830
80
REC10-xx15SRWLZ
9-36, 18-72
15
670
81
REC10-xx24SRWLZ
9-36, 18-72
24
416
79
REC10-xx05DRWLZ
9-36, 18-72
±5
±1.000
78
REC10-xx12DRWLZ
9-36, 18-72
±12
±416
81
REC10-xx15DRWLZ
9-36, 18-72
±15
±333
81
2:1
xx = 9-18Vin = 12
xx = 18-36Vin = 24
xx = 36-72Vin = 48
10 Watt
1” x 2”
Single &
Dual Output
* add suffix "CTRL" for optional Remote ON/OFF-Control
4:1
xx = 9-36Vin = 24
xx = 18-72Vin = 48
Specifications (Core Operating Area)
Input Voltage Range
2:1 & 4:1
Output Voltage Accuracy
±2% max.
Line Voltage Regulation
±0.2% max.
Load Voltage Regulation (10% to 100% full load )
±0.2% max.
Output Ripple and Noise (at 20MHz BW)
200kHz typ.
(tested for 1 second)
(long term isolation)
1.000VDC min.
see Application Notes
Isolation Capacitance
500pF max
Isolation Resistance
1 GΩ min.
Short Circuit Protection
Continuous
Operating Temperature Range (free air convection)
-25°C to +70°C (see Graph)
Storage Temperature Range
-55°C to +100°C
MSL Level 1
95% RH
Case Material
80
60
Safe Operating Area
40
20
0
-25
0
25
50
Operating Temperature (°C)
75 100
70 90
Metal Case
Package Weight
MTBF (+25°C) Detailed Information see
using MIL-HDBK 217F
(+70°C) Application Notes chapter "MTBF" using MIL-HDBK 217F
}
112
120
100
75% max.
Output Power (%)
Efficiency at Full Load
Relative Humidity
(Ambient Temperature)
100mVp-p max.
Operating Frequency
Isolation Voltage
Rated Working Voltage
Derating-Graph
April-2005
31.2 g
700 x 103 hours
560 x 103 hours
www.recom-international.com
ECONOLINE
REC10-S_DRWL(Z)
Series
DC/DC-Converter
Typical Characteristics
REC10 - types
Efficiency / Load
100
80
60
Efficiency %
40
20
0
40%
20%
60%
Total Output current (%)
100%
80%
Package Style and Pinning (mm) 1” x 2” , Wide Input 2:1 & 4:1
3rd angle
projection
1“ x 2“ PIN Package
50.80
25.40
25.40
20.40
20.40
11.27
8.30
20.32
15.24
Recommended Footprint Details
Pin Connections
5.08
1
2
Pin #
1
2
3
4
5
5
3
10.20
Bottom View 4
2
2.54
1
4
7.66
Top View
2.54
Dual
+ Vin
– Vin
+ Vout
Com
– Vout
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
3
5
Single
+ Vin
– Vin
+ Vout
No Pin
– Vout
1.2ø+0.2/–0.1
REC10-Series also available with Remote ON/OFF - Control
For detailed information please contact your RECOM representative.
Recommended Footprint Details
Pin Connections
3
5.08
5.08
1
2
6
6
10.20
Bottom View 4
2
2.54
1
5
Pin #
1
2
3
4
5
6
4
7.66
3
5
2.54
www.recom-international.com
April-2005
Top View
1.2ø+0.2/–0.1
Single
+ Vin
– Vin
+ Vout
No Pin
– Vout
Remote ON/OFF
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
113