RECOM REC15

Features
Regulated
Converters
●
●
●
●
●
●
●
●
ECONOLINE
15W 2”x 2” Package (50.8x50.8x11.0mm)
1kVDC Isolation
Wide Input 2:1 & 4:1
Regulated Output
UL94V-0 Package Material
Continuous Short Circuit Protection
Remote ON/OFF-Control for Single Types
Efficiency to 81%
DC/DC-Converter
REC15S_DRWB(Z)
Series
Selection Guide
Part
Number
2” x 2”
Input
Voltage
(VDC)
Output
Voltage
(VDC)
Output
Current
(mA)
Efficiency
REC15-xx05SRWB
9-18, 18-36, 36-72
5
3.000
77
REC15-xx12SRWB
9-18, 18-36, 36-72
12
1.250
80
REC15-xx15SRWB
9-18, 18-36, 36-72
15
1.000
80
REC15-xx24SRWB
9-18, 18-36, 36-72
24
625
81
REC15-xx05DRWB
9-18, 18-36, 36-72
±5
±1.500
77
REC15-xx12DRWB
9-18, 18-36, 36-72
±12
±625
80
REC15-xx15DRWB
9-18, 18-36, 36-72
±15
±500
80
REC15-xx05SRWBZ
9-36, 18-72
5
3.000
77
REC15-xx12SRWBZ
9-36, 18-72
12
1.250
80
REC15-xx15SRWBZ
9-36, 18-72
15
1.000
80
REC15-xx24SRWBZ
9-36, 18-72
24
625
77
REC15-xx05DRWBZ
9-36, 18-72
±5
±1.500
80
REC15-xx12DRWBZ
9-36, 18-72
±12
±625
80
REC15-xx15DRWBZ
9-36, 18-72
±15
±500
79
2:1
xx = 9-18Vin = 12
xx = 18-36Vin = 24
xx = 36-72Vin = 48
(%)
15 Watt
2” x 2”
Single &
Dual Output
4:1
xx = 9-36Vin = 24
xx = 18-72Vin = 48
Specifications (Core Operating Area)
Input Voltage Range
2:1 & 4:1
Output Voltage Accuracy
±2% max.
Line Voltage Regulation
±0.2% max.
Load Voltage Regulation (10% to 100% full load )
±0.2% max.
Output Ripple and Noise (at 20MHz BW)
200kHz typ.
(tested for 1 second)
(long term isolation)
1.000VDC min.
see Application Notes
Isolation Capacitance
550pF max
Isolation Resistance
1 GΩ min.
Short Circuit Protection
Continuous
Operating Temperature Range (free air convection)
-25°C to +70°C (see Graph)
Storage Temperature Range
-55°C to +100°C
MSL Level 1
95% RH
Case Material
80
60
Safe Operating Area
40
20
0
-25
0
25
50
Operating Temperature (°C)
75 100
70 90
Metal Case
Package Weight
MTBF (+25°C) Detailed Information see
using MIL-HDBK 217F
(+70°C) Application Notes chapter "MTBF" using MIL-HDBK 217F
}
114
120
100
75% max.
Output Power (%)
Efficiency at Full Load
Relative Humidity
(Ambient Temperature)
100mVp-p max.
Operating Frequency
Isolation Voltage
Rated Working Voltage
Derating-Graph
April-2005
60 g
700 x 103 hours
560 x 103 hours
www.recom-international.com
ECONOLINE
REC15-S_DRWB(Z)
Series
DC/DC-Converter
Typical Characteristics
REC15 - types
Efficiency / Load
100
80
60
Efficiency %
40
20
0
40%
20%
60%
Total Output current (%)
100%
80%
Package Style and Pinning (mm) 2” x 2” , Wide Input 2:1 & 4:1
3rd angle
projection
2“ x 2“ PIN Package
50.80
50.80
Side View
11.00
8.30
10.20
20.32
10.20
Recommended Footprint Details
Pin Connections
Pin #
22.82
5.12
Bottom View
5
3
1
2
2
1
4
5
15.20
Dual
+Vin
+Vin
2
–Vin
–Vin
3
+Vout
+Vout
4
No Pin
Com
5
–Vout
–Vout
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
4
3
2.54
2.54
www.recom-international.com
Single
1
April-2005
Top View
1.2ø+0.2/–0.1
115