Intersil HC5518XEVAL1 Voip ringing slic family Datasheet

HC55185
TM
Data Sheet
April 2000
File Number
VoIP Ringing SLIC Family
Features
The RSLIC-VoIP family of
ringing subscriber line
interface circuits (RSLIC)
supports analog Plain Old
Telephone Service (POTS) in
short and medium loop length, wireless and wireline
applications. Ideally suited for remote subscriber units, this
family of products offers flexibility to designers with high
ringing voltage and low power consumption system
requirements.
• Onboard Ringing Generation
The RSLIC-VoIP family operates to 100V which translates
directly to the amount of ringing voltage supplied to the end
subscriber. With the high operating voltage, subscriber loop
lengths can be extended to 500Ω (i.e., 5,000 feet) and
beyond.
• Pulse Metering and On Hook Transmission
4831.2
• Compatible with Existing HC5518x Devices
• Low Standby Power Consumption (75V, 65mW)
• Reduced Idle Channel Noise
• Programmable Transient Current Limit
• Improved Off Hook Software Interface
• Integrated MTU DC Characteristics
• Low External Component Count
• Silent Polarity Reversal
• Tip Open Ground Start Operation
• Thermal Shutdown with Alarm Indicator
• 28 Lead Surface Mount Packaging
• Dielectric Isolated (DI) High Voltage Design
Other key features across the product family include: low
power consumption, ringing using sinusoidal or trapezoidal
waveforms, robust auto-detection mechanisms for when
subscribers go on or off hook, and minimal external discrete
application components. Integrated test access features are
also offered on selected products to support loopback
testing as well as line measurement tests.
Applications
• Voice Over Internet Protocol (VoIP)
• Cable Modems
• Voice Over DSL (VoDSL)
• Short Loop Access Platforms
There are five product offerings of the HC55185 with each
version providing voltage grades of high battery voltage and
longitudinal balance. The voltage feed amplifier design uses
low fixed loop gains to achieve high analog performance with
low susceptibility to system induced noise.
• Remote Subscriber Units
• Terminal Adapters
Related Literature
• AN9814, User’s Guide for Development Board
• AN9824, Modeling of the AC Loop
• Interfacing to DSP CODECs (Contact Factory)
Block Diagram
POL
ILIM
TIP
CDC
DC
CONTROL
SW+
SW-
VBH
BATTERY
SWITCH
RINGING
PORT
VRS
TRANSMIT
SENSING
4-WIRE
PORT
VRX
VTX
-IN
VFB
DETECTOR
LOGIC
CONTROL
LOGIC
2-WIRE
PORT
RING
TL
VBL
TRANSIENT
CURRENT
LIMIT
TEST
ACCESS
RTD RD E0 DET ALM
4-1
BSEL
F2
F1
F0
SWC
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
1-888-INTERSIL or 321-724-7143 | Intersil and Design is a trademark of Intersil Corporation. | Copyright © Intersil Corporation 2000
RSLIC18™ is a trademark of Intersil Corporation.
HC55185
Ordering Information (PLCC Package Only)
PART NUMBER
LONGITUDINAL
BALANCE
HIGH BATTERY (VBH)
100V
85V
75V
•
HC55185BIM
TEMP.
RANGE oC
PACKAGE
PACKAGE
NO.
•
•
-40 to 85
28 Ld PLCC
N28.45
•
•
-40 to 85
28 Ld PLCC
N28.45
•
•
-40 to 85
28 Ld PLCC
N28.45
•
•
-40 to 85
28 Ld PLCC
N28.45
0 to 75
28 Ld PLCC
N28.45
0 to 85
28 Ld PLCC
N28.45
58dB
•
HC55185AIM
FULL
TEST
53dB
•
HC55185CIM
•
HC55185DIM
HC55185ECM
•
•
HC55185FCM
•
•
HC5518XEVAL1
•
Evaluation board platform, including CODEC.
Also available in Tape and Reel
Device Operating Modes
MODE
F2
F1
F0
E0 = 1
E0 = 0
HC55185A
HC55185B
HC55185C
HC55185D
HC55185E
HC55185F
Low Power Standby
0
0
0
SHD
GKD
•
•
•
•
•
•
Forward Active
0
0
1
SHD
GKD
•
•
•
•
•
•
Unused
0
1
0
n/a
n/a
Reverse Active
0
1
1
SHD
GKD
•
•
•
•
•
•
Ringing
1
0
0
RTD
RTD
•
•
•
•
•
•
Forward Loop Back
1
0
1
SHD
GKD
•
•
•
•
Tip Open
1
1
0
SHD
GKD
•
•
•
•
Power Denial
1
1
1
n/a
n/a
•
•
•
Device Pinout
4-2
TIP
2
1
ILIM
BGND
3
RD
VBL
4
RING
VBH
HC55185
(PLCC)
TOP VIEW
28 27 26
SW+
5
25 RTD
SW-
6
24 CDC
SWC
7
23 VCC
F2
8
22 -IN
F1
9
21 VFB
F0
10
20 VTX
E0
11
13
14 15
16
17
18
DET
ALM
AGND
BSEL
TL
POL
VRS
19 VRX
12
•
•
•
HC55185
Absolute Maximum Ratings
TA = 25oC
Thermal Information
Maximum Supply Voltages
VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.5V to +7V
VCC - VBH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110V
Uncommitted Switch Voltage . . . . . . . . . . . . . . . . . . . . . . . -110V
ESD (Human Body Model). . . . . . . . . . . . . . . . . . . . . . . . . . . . 500V
Thermal Resistance (Typical, Note 1)
θJA
PLCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53oC/W
Maximum Junction Temperature Plastic . . . . . . . . . . . . . . . . 150oC
Maximum Storage Temperature Range . . . . . . . . . . -65oC to 150oC
Maximum Lead Temperature (Soldering 10s) . . . . . . . . . . . . 300oC
(PLCC - Lead Tips Only)
Operating Conditions
Temperature Range
Commercial (C suffix) . . . . . . . . . . . . . . . . . . . . . . . . . . 0oC to 85oC
Industrial (I suffix) . . . . . . . . . . . . . . . . . . . . . . . . . . . -40oC to 85oC
Positive Power Supply (VCC) . . . . . . . . . . . . . . . . . . . . . . . +5V, ±5%
Low Battery Power Supply (VBL) . . . . . . . . . . . . . -16V to -52V, ±5%
High Battery Power Supply (VBH)
AIM, CIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .VBL to 100V, ±5%
BIM, DIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VBL to -85V, ±10%
EIM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VBL to -75V, ±10%
Uncommitted Switch (loop back or relay driver). . . . . . +5V to -100V
Die Characteristics
Substrate Potential. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VBH
Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bipolar-DI
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of the
device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
NOTE:
1. θJA is measured with the component mounted on an evaluation PC board in free air.
Electrical Specifications
Unless Otherwise Specified, TA = -40oC to 85oC for industrial (I) grade and TA = 0oC to 85oC for commercial
(C) grade, VBL = -24V, VBH = -100V, -85V or -75V, VCC = +5V, AGND = BGND = 0V, loop current limit = 25mA.
All AC parameters are specified at 600Ω 2-wire terminating impedance over the frequency band of 300Hz to
3.4kHz. Protection resistors = 0Ω.
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNITS
450
-
-
kΩ
78
80
82
V/V
RINGING PARAMETERS
VRS Input Impedance (Note 2)
Differential Ringing Gain (Note 3)
VRS to 2-wire, RLOAD = ∞
Ringing Voltage Total Distortion
RL = 1.3 kΩ, VT-R = |VBH| -5
-
-
3.0
%
4-Wire to 2-Wire Ringing Off Isolation
Active mode, referenced to VRS input
-
90
-
dB
2-Wire to 4-Wire Transmit Isolation
Ringing mode referenced to the differential ringing
amplitude
-
80
-
dB
Centering Voltage Accuracy
Tip, Referenced to VBH/2 + 0.5
-
2.5
-
V
Ring, Referenced to VBH/2 + 0.5
-
2.5
-
V
160
-
-
kΩ
-
-
1
Ω
AC TRANSMISSION PARAMETERS
Receive Input Impedance (Note 2)
Transmit Output Impedance (Note 2)
4-Wire Port Overload Level
THD = 1%
3.1
3.5
-
VPK
2-Wire Port Overload Level
THD = 1%
3.1
3.5
-
VPK
2-Wire Return Loss
300Hz
-
24
-
dB
1kHz
-
40
-
dB
3.4kHz
-
21
-
dB
Forward Active, Grade A and B
58
62
-
dB
Forward Active, Grade C, D and E
53
59
-
dB
Forward Active, Grade A and B
58
67
-
dB
Forward Active, Grade C, D and E
53
64
-
dB
2-Wire Longitudinal Balance (Notes 4, 5)
4-Wire Longitudinal Balance
4-3
HC55185
Electrical Specifications
Unless Otherwise Specified, TA = -40oC to 85oC for industrial (I) grade and TA = 0oC to 85oC for commercial
(C) grade, VBL = -24V, VBH = -100V, -85V or -75V, VCC = +5V, AGND = BGND = 0V, loop current limit = 25mA.
All AC parameters are specified at 600Ω 2-wire terminating impedance over the frequency band of 300Hz to
3.4kHz. Protection resistors = 0Ω.
PARAMETER
MIN
TYP
MAX
UNITS
+3 to -40dBm, 1kHz
-
0.025
-
dB
-40 to -50dBm, 1kHz
-
0.050
-
dB
-50 to -55dBm, 1kHz
-
0.100
-
dB
Test for False Detect
20
-
-
mARMS
Test for False Detect, Low Power Standby
10
-
-
mARMS
4-Wire to 2-Wire Insertion Loss
-0.20
0.00
+0.20
dB
2-Wire to 4-Wire Insertion Loss
-6.22
-6.02
-5.82
dB
2-Wire to 4-Wire Level Linearity
4-Wire to 2-Wire Level Linearity
Referenced to -10dBm
Longitudinal Current Capability (Per Wire) (Note 2)
TEST CONDITIONS
4-Wire to 4-Wire Insertion Loss
-6.22
-6.02
-5.82
dB
2-Wire C-Message, T = 25oC
-
10
13
dBrnC
4-Wire C-Message, T = 25oC
-
4
7
dBrnC
2-Wire C-Message, T = 25oC
-
11
14
dBrnC
4-Wire C-Message, T = 25oC
-
5
8
dBrnC
-8.5
-
+8.5
%
Programming Range
15
-
45
mA
Programming Accuracy
-10
-
+10
%
Programming Range
40
-
100
mA
Loop Current During Low Power Standby
Forward Polarity Only
18
-
26
mA
Open Circuit Voltage
(|Tip - Ring|)
VBL = -16V
-
8.0
-
VDC
VBL = -24V
14
15.5
17
VDC
VBH > -60V
43
49
-
VDC
VBL = -48V
-
44.5
-
VDC
VBH > -60V
43
51.5
-
VDC
VRG in LPS and FA
VTG in RA
VBH > -60V
-
-53
-56
VDC
IOL = 45mA
-
0.30
0.60
V
-
-
52
V
5
-
15
mA
-10
-
+10
%
-
-
1
%
Ring Trip Comparator Threshold
2.3
2.45
2.9
V
Ring Trip Programming Current Accuracy
-10
-
+10
%
-
12
-
mA
-
175
-
oC
Forward Active Idle Channel Noise (Note 5)
Reverse Active Idle Channel Noise (Note 5)
DC PARAMETERS
Off Hook Loop Current Limit
Programming Accuracy
Off Hook Transient Current Limit
Low Power Standby
Open Circuit Voltage
(Tip - Ring)
Absolute Open Circuit Voltage
TEST ACCESS FUNCTIONS
Switch On Voltage
Loopback Max Battery
LOOP DETECTORS AND SUPERVISORY FUNCTIONS
Switch Hook Programming Range
Switch Hook Programming Accuracy
Assumes 1% External Programming Resistor
Dial Pulse Distortion
Ground Key Threshold
Thermal Alarm Output
IC Junction Temperature
4-4
HC55185
Electrical Specifications
Unless Otherwise Specified, TA = -40oC to 85oC for industrial (I) grade and TA = 0oC to 85oC for commercial
(C) grade, VBL = -24V, VBH = -100V, -85V or -75V, VCC = +5V, AGND = BGND = 0V, loop current limit = 25mA.
All AC parameters are specified at 600Ω 2-wire terminating impedance over the frequency band of 300Hz to
3.4kHz. Protection resistors = 0Ω.
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNITS
Input Low Voltage
-
-
0.8
V
Input High Voltage
2.0
-
-
V
LOGIC INPUTS (F0, F1, F2, E0, SWC)
Input Low Current
VIL = 0.4V
-20
-
-
µA
Input High Current
VIH = 2.4V
-
-
1
µA
Output Low Voltage
IOL = 5mA
-
.15
0.4
V
Output High Voltage
IOH = 100µA
2.4
3.5
-
V
ICC
-
3.9
6.0
mA
IBH
-
0.66
0.90
mA
ICC
-
4.9
6.5
mA
IBL
-
1.2
2.5
mA
ICC
-
7.0
9.5
mA
IBL
-
0.9
2.0
mA
IBH
-
2.2
3.0
mA
ICC
-
6.4
9.0
mA
IBL
-
0.3
1.0
mA
IBH
-
2.0
3.0
mA
ICC
-
10.3
13.5
mA
IBL
-
23.5
32
mA
ICC
-
3.8
5.5
mA
IBL
-
.3
1.0
mA
ICC
-
4.0
6.0
mA
IBL
-
0.22
0.5
mA
Forward or Reverse
VBL = -24V
-
55
-
mW
Low Power Standby
VBH = -100V
-
85
-
mW
VBH = -85V
-
75
-
mW
VBH = -75V
-
65
-
mW
VBH = -100V
-
250
-
mW
VBH = -85V
-
230
-
mW
VBH = -75V
-
225
-
mW
VBL = -24V
-
305
-
mW
LOGIC OUTPUTS (DET, ALM)
SUPPLY CURRENTS
Low Power Standby, BSEL = 1
Forward or Reverse, BSEL = 0
Forward, BSEL = 1
Ringing, BSEL = 1
Forward Loopback, BSEL = 0
Tip Open, BSEL = 0
Power Denial, BSEL = 0 or 1
ON HOOK POWER DISSIPATION (Note 6)
Ringing
OFF HOOK POWER DISSIPATION (Note 6)
Forward or Reverse
POWER SUPPLY REJECTION RATIO
4-5
HC55185
Electrical Specifications
Unless Otherwise Specified, TA = -40oC to 85oC for industrial (I) grade and TA = 0oC to 85oC for commercial
(C) grade, VBL = -24V, VBH = -100V, -85V or -75V, VCC = +5V, AGND = BGND = 0V, loop current limit = 25mA.
All AC parameters are specified at 600Ω 2-wire terminating impedance over the frequency band of 300Hz to
3.4kHz. Protection resistors = 0Ω.
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNITS
f = 300Hz
-
40
-
dB
f = 1kHz
-
35
-
dB
f = 3.4kHz
-
28
-
dB
f = 300Hz
-
45
-
dB
f = 1kHz
-
43
-
dB
f = 3.4kHz
-
33
-
dB
VBL to 2-Wire
300Hz ≤ f ≤ 3.4kHz
-
30
-
dB
VBL to 4-Wire
300Hz ≤ f ≤ 3.4kHz
-
35
-
dB
VBH to 2-Wire
300Hz ≤ f ≤ 3.4kHz
-
33
-
dB
VBH to 4-Wire
300Hz ≤ f ≤ 1kHz
-
40
-
dB
1kHz < f ≤ 3.4kHz
-
45
-
dB
VCC to 2-Wire
VCC to 4-Wire
NOTES:
2. These parameters are controlled via design or process parameters and are not directly tested. These parameters are characterized upon initial
design release and upon design changes which would affect these characteristics.
3. Differential Ringing Gain is measured with VRS = 0.795VRMS for -100V devices, VRS = 0.663 VRMS for -85V devices and VRS = 0.575VRMS
for -75V devices.
4. Longitudinal Balance is tested per IEEE455-1985, with 368Ω per Tip and Ring terminal.
5. These parameters are tested 100% at room temperature. These parameters are guaranteed not tested across temperature via statistical
characterization and design.
6. The power dissipation is based on actual device measurements and will be less than worst case calculations based on data sheet supply current
limits.
Product Family Cross Reference
The following table provides an ordering and functional cross
reference for the existing HC55180 thru HC55184 products
and the new and improved HC55185 product.
feature. This programming resistor is connected from pin 16
(TL) to ground. In addition some component values have
been changed to improve overall device performance. The
table below lists the component value changes required for
the HC55185 application circuit.
TABLE 1. PRODUCT CROSS REFERENCE
EXISTING DEVICES
TABLE 2. COMPONENT VALUE CHANGES
FUNCTIONAL EQUIVALENT
HC55180CIM, HC55180DIM
None Offered
HC55181AIM, HC55182AIM
HC55185AIM
HC55181BIM, HC55182BIM
HC55185BIM
HC55181CIM, HC55182CIM
HC55185CIM
HC55181DIM, HC55182DIM
HC55185DIM
HC55183ECM, HC55184ECM
HC55185ECM
Any of the HC55185 products may be used without the
battery switch function by shorting the supply pins VBL and
VBH together. This provides compatibility with HC55180
type applications which do not require the battery switch.
Application Circuit Modifications
The HC55185 basic application circuit is nearly identical to
that of the HC55180 thru HC55184.The HC55185 requires
an additional resistor to program the transient current limit
4-6
REFERENCE
HC55180 - 184
HC55185
RS
210kΩ
66.5kΩ
RP1
≥ 35Ω
≥ 49Ω
RP2
≥ 35Ω
≥ 49Ω
CFB
0.47µ
4.7µ
The value of RS is based on a 600Ω termination impedance
and RP1 = RP2 = 49.9Ω. Design equations are provided to
calculate RS for other combinations of termination and
protection resistance.
The CFB capacitor must be non-polarized for proper device
operation in Reverse Active. Ceramic surface mount
capacitors (1206 body style) are available from Panasonic
with a 6.3V voltage rating. These can be used for CFB since
it is internally limited to approximately 3V. The CDC
capacitor may be either polarized or non polarized.
HC55185
Parametric Improvements
FUNCTIONAL DESCRIPTION
The most significant parametric improvement of the
HC55185 is reduction in Idle Channel Noise. This
improvement was accomplished by redistributing gains in
the impedance matching loop. The impact to the application
circuit is the change in the impedance programming resistor
RS. The redistribution of gains also improves AC
performance at the upper end of the voice band.
Each amplifier is designed to limit source current and sink
current. The diagram below shows the functionality of the
circuit for the case of limiting the source current. A similar
diagram applies to the sink current limit with current polarity
changed accordingly.
IO/K
IREF = 1.21/TL
IERR
Functional Improvements
200k
In addition to parametric improvements, internal circuit
changes and application circuit changes have been made to
improve the overall device functionality.
+
ISIG VB/2
Off Hook Interface
The transient behavior of the device in response to mode
changes has been significantly improved. The benefit to the
application is reduction or more likely elimination of DET
glitches when off hook events occur. In addition to internal
circuit modifications, the change of CFB value contributes to
this functional improvement.
Transient Current Limit
The drive current capability of the output amplifiers is
determined by an externally programmable output current
limit circuit which is separate from the DC loop current limit
function and programmed at the pin TL. The current limit
circuit works in both the source and sink direction, with an
internally fixed offset to prevent the current limit functions
from turning on simultaneously. The current limit function is
provided by sensing line current and reducing the voltage
drive to the load when the externally set threshold is
exceeded, hence forcing a constant source or sink current.
SOURCE CURRENT PROGRAMMING
(EQ. 1)
For example a source current limit setting of 50mA is
programmed with a 35.6kΩ resistor connected from pin 16 of
the device to ground. This setting determines the maximum
amount of current which flows from Tip to Ring during an off
hook event until the DC loop current limit responds. In
addition this setting also determines the amount of current
which will flow from Tip or Ring when external battery faults
occur.
SINK CURRENT PROGRAMMING
The sink current limit is internally offset 20% higher than the
externally programmed source current limit setting.
(EQ. 2)
I SNK = 1.20 × I SRC
If the source current limit is set to 50mA, the sink current
limit will be 60mA. This setting will determine the amount of
which flows into Tip or Ring when external ground faults
occur.
4-7
20
IO
FIGURE 1. CURRENT LIMIT FUNCTIONAL DIAGRAM
During normal operation, the error current (IERR) is zero and
the output voltage is determined by the signal current (ISIG)
multiplied by the 200k feedback resistor. With the current
polarity as shown for ISIG, the output voltage moves positive
with respect to half battery. Assuming the amplifier output is
driving a load at a more negative potential, the amplifier
output will source current.
During excessive output source current flow, the scaled
output current (IO/K) exceeds the reference current (IREF)
forcing an error current (IERR). With the polarity as shown
the error current subtracts from the signal current, which
reduces the amplifier output voltage. By reducing the output
voltage the source current to the load is decreased and the
output current is limited.
DETERMINING THE PROPER SETTING
The source current is externally programmed as shown in
Equation 1.
1780
R TL = ------------I SRC
TIP or RING
Since this feature programs the maximum output current of
the device, the setting must be high enough to allow for
detection of ring trip or programmed off hook loop current,
whichever is greater.
To allow for proper ring trip operation, the transient current
limit setting should be set at least 25% higher than the peak
ring trip current setting. Setting the transient current 25%
higher should account for programming tolerances of both
the ring trip threshold and the transient current limit.
If loop current is larger than ring trip current (low REN
applications) then the transient current limit should be set at
least 35% higher than the loop current setting. The slightly
higher offset accounts for the slope of the loop current limit
function.
Attention to detail should be exercised when programming
the transient current limit setting. If ring trip detect does not
occur while ringing, then re-examine the transient current
limit and ring trip threshold settings.
HC55185
Design Equations
4-WIRE TO 2-WIRE GAIN
Loop Supervision Thresholds
SWITCH HOOK DETECT
The switch hook detect threshold is set by a single external
resistor, RSH . Equation 3 is used to calculate the value of RSH.
(EQ. 3)
R SH = 600 ⁄ I SH
The 4-wire to 2-wire gain is defined as the receive gain. It is
a function of the terminating impedance, synthesized
impedance and protection resistors. Equation 8 calculates
the receive gain, G42.
ZL


G 42 = – 2  ------------------------------------------
 Z O + 2R P + Z L
(EQ. 8)
The term ISH is the desired DC loop current threshold. The
loop current threshold programming range is from 5mA to
15mA.
When the device source impedance and protection resistors
equals the terminating impedance, the receive gain equals
unity.
GROUND KEY DETECT
2-WIRE TO 4-WIRE GAIN
The ground key detector senses a DC current imbalance
between the Tip and Ring terminals when the ring terminal is
connected to ground. The ground key detect threshold is not
externally programmable and is internally fixed to 12mA
regardless of the switch hook threshold.
The 2-wire to 4-wire gain (G24) is the gain from tip and ring to
the VTX output. The transmit gain is calculated in Equation 9.
RING TRIP DETECT
When the protection resistors are set to zero, the transmit
gain is -6dB.
The ring trip detect threshold is set by a single external
resistor, RRT. IRT should be set between the peak ringing
current and the peak off hook current while still ringing. In
(EQ. 4)
R RT = 1800 ⁄ I RT
ZO


G 24 = –  ------------------------------------------
 Z O + 2R P + Z L
(EQ. 9)
TRANSHYBRID GAIN
The transhybrid gain is defined as the 4-wire to 4-wire gain
(G44).
addition, the ring trip current must be set below the transient
current limit, including tolerances. The capacitor CRT, in
parallel with RRT, will set the ring trip response time.
ZO


G 44 = –  ---------------------------------------
Z
+
2R
+
Z
 O
P
L
Loop Current Limit
When the protection resistors are set to zero, the transhybrid
gain is -6dB.
The loop current limit of the device is programmed by the
external resistor RIL. The value of RIL can be calculated
using Equation 5.
1760
R IL = ------------I LIM
(EQ. 5)
COMPLEX IMPEDANCE SYNTHESIS
Substituting the impedance programming resistor, RS, with a
complex programming network provides complex
impedance synthesis.
The term ILIM is the desired loop current limit. The loop
current limit programming range is from 15mA to 45mA.
Impedance Matching
2-WIRE
NETWORK
C2
R1
The impedance of the device is programmed with the
external component RS . RS is the gain setting resistor for
the feedback amplifier that provides impedance matching. If
complex impedance matching is required, then a complex
network can be substituted for RS .
RESISTIVE IMPEDANCE SYNTHESIS
The source impedance of the device, ZO , can be calculated
in Equation 6.
(EQ. 6)
R S = 133.3 ( Z O )
The required impedance is defined by the terminating
impedance and protection resistors as shown in Equation 7.
(EQ. 7)
Z O = Z L – 2R P
4-8
(EQ. 10)
PROGRAMMING
NETWORK
CP
RS
R2
RP
FIGURE 2. COMPLEX PROGRAMMING NETWORK
The reference designators in the programming network
match the evaluation board. The component RS has a
different design equation than the RS used for resistive
impedance synthesis. The design equations for each
component are provided below.
R S = 133.3 × ( R 1 – 2 ( R P ) )
(EQ. 11)
R P = 133.3 × R 2
(EQ. 12)
˙
C P = C 2 ⁄ 133.3
(EQ. 13)
HC55185
Low Power Standby
Overview
The low power standby mode (LPS, 000) should be used
during idle line conditions. The device is designed to operate
from the high battery during this mode. Most of the internal
circuitry is powered down, resulting in low power dissipation.
If the 2-wire (tip/ring) DC voltage requirements are not
critical during idle line conditions, the device may be
operated from the low battery. Operation from the low
battery will decrease the standby power dissipation.
TABLE 3. DEVICE INTERFACES DURING LPS
INTERFACE
ON
OFF
NOTES
Receive
x
Ringing
x
AC transmission, impedance
matching and ringing are
disabled during this mode.
Transmit
x
2-Wire
x
Amplifiers disabled.
Loop Detect
x
Switch hook or ground key.
2-Wire Interface
During LPS, the 2-wire interface is maintained with internal
switches and voltage references. The Tip and Ring
amplifiers are turned off to conserve power. The device will
provide MTU compliance, loop current and loop supervision.
Figure 3 represents the internal circuitry providing the 2-wire
interface during low power standby.
GND
Ring terminal will be clamped by the internal reference. The
same Ring relationships apply when operating from the low
battery voltage. For high battery voltages (VBH) less than or
equal to the internal MTU reference threshold:
V RING = V BH + 4
(EQ. 14)
Loop Current
During LPS, the device will provide current to a load. The
current path is through resistors and switches, and will be
function of the off hook loop resistance (RLOOP). This
includes the off hook phone resistance and copper loop
resistance. The current available during LPS is determined
by Equation 15.
I LOOP = ( – 1 – ( – 49 ) ) ⁄ ( 600 + 600 + R LOOP )
(EQ. 15)
Internal current limiting of the standby switches will limit the
maximum current to 20mA.
Another loop current related parameter is longitudinal
current capability. The longitudinal current capability is
reduced to 10mARMS per pin. The reduction in longitudinal
current capability is a result of turning off the Tip and Ring
amplifiers.
On Hook Power Dissipation
The on hook power dissipation of the device during LPS is
determined by the operating voltages and quiescent currents
and is calculated using Equation 16.
P LPS = V BH × I BHQ + V BL × I BLQ + V CC × I CCQ
(EQ. 16)
600Ω
TIP AMP
TIP
RING
The quiescent current terms are specified in the electrical
tables for each operating mode. Load power dissipation is
not a factor since this is an on hook mode. Some
applications may specify a standby current. The standby
current may be a charging current required for modern
telephone electronics.
RING AMP
600Ω
MTU REF
FIGURE 3. LPS 2-WIRE INTERFACE CIRCUIT DIAGRAM
MTU Compliance
Maintenance Termination Unit or MTU compliance places
DC voltage requirements on the 2-wire terminals during idle
line conditions. The minimum idle voltage is 42.75V. The
high side of the MTU range is 56V. The voltage is expressed
as the difference between Tip and Ring.
The Tip voltage is held near ground through a 600Ω resistor
and switch. The Ring voltage is limited to a maximum of
-49V (by MTU REF) when operating from either the high or
low battery. A switch and 600Ω resistor connect the MTU
reference to the Ring terminal. When the high battery
voltage exceeds the MTU reference of -49V (typically), the
4-9
Standby Current Power Dissipation
Any standby line current, ISLC , introduces an additional
power dissipation term PSLC . Equation 17 illustrates the
power contribution is zero when the standby line current is
zero.
P SLC = I SLC × ( V BH – 49 + 1 + I SLC x1200 )
(EQ. 17)
If the battery voltage is less than -49V (the MTU clamp is
off), the standby line current power contribution reduces to
Equation 18.
P SLC = I SLC × ( V BH + 1 + I SLC x1200 )
(EQ. 18)
Most applications do not specify charging current
requirements during standby. When specified, the typical
charging current may be as high as 5mA.
HC55185
Forward Active
filter is set by the external capacitor CDC . The value of the
external capacitor should be 4.7µF.
On-Hook Transmission
The primary purpose of on hook transmission will be to
support caller ID and other advanced signalling features.
The transmission over load level while on hook is 3.5VPEAK .
When operating from the high battery, the DC voltages at Tip
and Ring are MTU compliant. The typical Tip voltage is -4V
and the Ring voltage is a function of the battery voltage for
battery voltages less than -60V as shown in Equation 19.
(EQ. 19)
V RING = V BH + 4
Loop supervision is provided by the switch hook detector at
the DET output. When DET goes low, the low battery should
be selected for DC loop feed and voice transmission.
Feed Architecture
The design implements a voltage feed current sense
architecture. The device controls the voltage across Tip and
Ring based on the sensing of load current. Resistors are
placed in series with Tip and Ring outputs to provide the
current sensing. The diagram below illustrates the concept.
RB
RA
VIN
RCS
-
VOUT
+
RL
Most applications will operate the device from low battery
while off hook. The DC feed characteristic of the device will
drive Tip and Ring towards half battery to regulate the DC
loop current. For light loads, Tip will be near -4V and Ring
will be near VVBL + 4V. The following diagram shows the DC
feed characteristic.
VTR(OC)
m = (∆VTR/∆IL) = 11.1kΩ
ILOOP (mA)
ILIM
FIGURE 5. DC FEED CHARACTERISTIC
The point on the y-axis labeled VTR(OC) is the open circuit
Tip to Ring voltage and is defined by the feed battery
voltage.
(EQ. 20)
V TR ( OC ) = V BL – 8
The curve of Figure 5 determines the actual loop current for
a given set of loop conditions. The loop conditions are
determined by the low battery voltage and the DC loop
impedance. The DC loop impedance is the sum of the
protection resistance, copper resistance (ohms/foot) and the
telephone off hook DC resistance.
IA
ISC
IB
ILIM
ILOOP (mA)
The forward active mode (FA, 001) is the primary AC
transmission mode of the device. On hook transmission, DC
loop feed and voice transmission are supported during forward
active. Loop supervision is provided by either the switch hook
detector (E0 = 1) or the ground key detector (E0 = 0). The
device may be operated from either high or low battery for onhook transmission and low battery for loop feed.
VTR , DC (V)
Overview
2RP
RC
RLOOP (Ω)
RKNEE
FIGURE 6. ILOOP VERSUS RLOOP LOAD CHARACTERISTIC
-
+
KS
FIGURE 4. VOLTAGE FEED CURRENT SENSE DIAGRAM
The slope of the feed characteristic and the battery voltage
define the maximum loop current on the shortest possible
loop as the short circuit current ISC.
V TR ( OC ) – 2R P I LIM
I SC = I LIM + -----------------------------------------------------1.1e4
By monitoring the current at the amplifier output, a negative
feedback mechanism sets the output voltage for a defined
load. The amplifier gains are set by resistor ratios (RA , RB ,
RC) providing all the performance benefits of matched
resistors. The internal sense resistor, RCS , is much smaller
than the gain resistors and is typically 20Ω for this device.
The feedback mechanism, KS , represents the amplifier
configuration providing the negative feedback.
The term ILIM is the programmed current limit, 1760/RIL.
The line segment IA represents the constant current region
of the loop current limit function.
DC Loop Feed
The maximum loop impedance for a programmed loop
current is defined as RKNEE .
The feedback mechanism for monitoring the DC portion of
the loop current is the loop detector. A low pass filter is used
in the feedback to block voice band signals from interfering
with the loop current limit function. The pole of the low pass
4-10
V TR ( OC ) – R LOOP I LIM
I A = I LIM + -------------------------------------------------------------1.1e4
V TR ( OC )
R KNEE = -----------------------I LIM
(EQ. 21)
(EQ. 22)
(EQ. 23)
HC55185
When RKNEE is exceeded, the device will transition from
constant current feed to constant voltage, resistive feed. The
line segment IB represents the resistive feed portion of the
load characteristic.
V TR ( OC )
I B = -----------------------R LOOP
maintain voice quality. Most applications will use a summing
amplifier in the CODEC front end as shown below to cancel
the echo signal.
R
(EQ. 24)
VRX
RA
VTX
RB
R
Voice Transmission
1:1
The feedback mechanism for monitoring the AC portion of
the loop current consists of two amplifiers, the sense
amplifier (SA) and the transmit amplifier (TA). The AC
feedback signal is used for impedance synthesis. A detailed
model of the AC feed back loop is provided below.
R
VRX
20
TIP
-
R
+
1:1
20
RING
VTX
+
-
TA
-
+
RS
R
4R
3R
4R
CFB
8K
-
+
VFB
VSA
3R
FIGURE 7. AC SIGNAL TRANSMISSION MODEL
The gain of the transmit amplifier, set by RS , determines the
programmed impedance of the device. The capacitor CFB
blocks the DC component of the loop current. The ground
symbols in the model represent AC grounds, not actual DC
potentials.
The sense amp output voltage, VSA , as a function of Tip and
Ring voltage and load is calculated using Equation 25.
30
V SA = – ( V T – V R ) -----ZL
(EQ. 25)
The transmit amplifier provides the programmable gain
required for impedance synthesis. In addition, the output of
this amplifier interfaces to the CODEC transmit input. The
output voltage is calculated using Equation 26.
RS
V VTX = – V SA  ----------
 8e3
+
TX IN
+2.4V
-IN
HC5518x
CODEC
FIGURE 8. TRANSHYBRID BALANCE INTERFACE
The resistor ratio, RF /RB , provides the final adjustment for
the transmit gain, GTX . The transmit gain is calculated using
Equation 27.
 R F
-
TX = – G 24  ------ R B
(EQ. 27)
-IN
4R
4R
RF
RS
+
R
TA
RX OUT
(EQ. 26)
Once the impedance matching components have been
selected using the design equations, the above equations
provide additional insight as to the expected AC node
voltages for a specific Tip and Ring load.
Most applications set RF = RB , hence the device 2-wire to
4-wire equals the transmit gain. Typically RB is greater than
20kΩ to prevent loading of the device transmit output.
The resistor ratio, RF /RA , is determined by the transhybrid
gain of the device, G44 . RF is previously defined by the
transmit gain requirement and RA is calculated using
Equation 28.
RB
R A = ---------G 44
(EQ. 28)
Power Dissipation
The power dissipated by the device during on hook
transmission is strictly a function of the quiescent currents
for each supply voltage during Forward Active operation.
+ V BL × I BLQ + V CC × I CCQ
P FAQ = V BH × I
BHQ
(EQ. 29)
Off hook power dissipation is increased above the quiescent
power dissipation by the DC load. If the loop length is less
than or equal to RKNEE , the device is providing constant
current, IA , and the power dissipation is calculated using
Equation 30.
P FA ( IA ) = P FA ( Q ) + ( V BL xI A ) – ( R LOOP xI 2 A )
(EQ. 30)
If the loop length is greater than RKNEE , the device is
operating in the constant voltage, resistive feed region. The
power dissipated in this region is calculated using Equation 31.
P FA ( IB ) = P FA ( Q ) + ( V BL xI B ) – ( R LOOP xI 2 B )
(EQ. 31)
Transhybrid Balance
The final step in completing the impedance synthesis design
is calculating the necessary gains for transhybrid balance.
The AC feed back loop produces an echo at the VTX output
of the signal injected at VRX . The echo must be cancelled to
4-11
Since the current relationships are different for constant
current versus constant voltage, the region of device
operation is critical to valid power dissipation calculations.
HC55185
Reverse Active
Ringing
Overview
Overview
The reverse active mode (RA, 011) provides the same
functionality as the forward active mode. On hook
transmission, DC loop feed and voice transmission are
supported. Loop supervision is provided by either the switch
hook detector (E0 = 1) or the ground key detector (E0 = 0).
The device may be operated from either high or low battery.
The ringing mode (RNG, 100) provides linear amplification
to support a variety of ringing waveforms. A programmable
ring trip function provides loop supervision and auto
disconnect upon ring trip. The device is designed to operate
from the high battery during this mode.
During reverse active the Tip and Ring DC voltage
characteristics exchange roles. That is, Ring is typically 4V
below ground and Tip is typically 4V more positive than
battery. Otherwise, all feed and voice transmission
characteristics are identical to forward active.
The device provides linear amplification to the signal applied
to the ringing input, VRS . The differential ringing gain of the
device is 80V/V. The circuit model for the ringing path is
shown in the following figure.
Architecture
R
R/8
Silent Polarity Reversal
Changing from forward active to reverse active or vice versa
is referred to as polarity reversal. Many applications require
slew rate control of the polarity reversal event. Requirements
range from minimizing cross talk to protocol signalling.
The device uses an external low voltage capacitor, CPOL , to
set the reversal time. Once programmed, the reversal time
will remain nearly constant over various load conditions. In
addition, the reversal timing capacitor is isolated from the AC
loop, therefore loop stability is not impacted.
The internal circuitry used to set the polarity reversal time is
shown below.
I1
POL
75kΩ
CPOL
I2
FIGURE 9. REVERSAL TIMING CONTROL
During forward active, the current from source I1 charges the
external timing capacitor CPOL and the switch is open. The
internal resistor provides a clamping function for voltages on
the POL node. During reverse active, the switch closes and
I2 (roughly twice I1) pulls current from I1 and the timing
capacitor. The current at the POL node provides the drive to
a differential pair which controls the reversal time of the Tip
and Ring DC voltages.
∆time
C POL = ---------------75000
(EQ. 32)
Where ∆time is the required reversal time. Polarized
capacitors may be used for CPOL . The low voltage at the
POL pin and minimal voltage excursion ±0.75V, are well
suited to polarized capacitors.
Power Dissipation
The power dissipation equations for forward active operation
also apply to the reverse active mode.
4-12
20
TIP
-
+
-
+
5:1
20
+
RING
-
VRS
600K
+ VBH
2
R
FIGURE 10. LINEAR RINGING MODEL
The voltage gain from the VRS input to the Tip output is
40V/V. The resistor ratio provides a gain of 8 and the current
mirror provides a gain of 5. The voltage gain from the VRS
input to the Ring output is -40V/V. The equations for the Tip
and Ring outputs during ringing are provided below.
V BH
V T = ----------- + ( 40 × VRS )
2
(EQ. 33)
V BH
V R = ----------- – ( 40 × VRS )
2
(EQ. 34)
When the input signal at VRS is zero, the Tip and Ring
amplifier outputs are centered at half battery. The device
provides auto centering for easy implementation of
sinusoidal ringing waveforms. Both AC and DC control of the
Tip and Ring outputs is available during ringing. This feature
allows for DC offsets as part of the ringing waveform.
Ringing Input
The ringing input, VRS , is a high impedance input. The high
impedance allows the use of low value capacitors for AC
coupling the ring signal. The VRS input is enabled only
during the ringing mode, therefore a free running oscillator
may be connected to VRS at all times.
When operating from a battery of -100V, each amplifier, Tip
and Ring, will swing a maximum of 95VP-P. Hence, the
maximum signal swing at VRS to achieve full scale ringing is
approximately 2.4VP-P. The low signal levels are compatible
with the output voltage range of the CODEC. The digital
nature of the CODEC ideally suits it for the function of
programmable ringing generator. See Applications Section.
HC55185
Forward Loop Back
Logic Control
Ringing patterns consist of silent intervals. The ringing to
silent pattern is called the ringing cadence. During the silent
portion of ringing, the device can be programmed to any
other operating mode. The most likely candidates are low
power standby or forward active. Depending on system
requirements, the low or high battery may be selected.
Loop supervision is provided with the ring trip detector. The ring
trip detector senses the change in loop current when the phone
is taken off hook. The loop detector full wave rectifies the
ringing current, which is then filtered with external components
RRT and CRT. The resistor RRT sets the trip threshold and the
capacitor CRT sets the trip response time. Most applications will
require a trip response time less than 150ms.
Overview
The Forward Loop Back mode (FLB, 101) provides test
capability for the device. An internal signal path is enabled
allowing for both DC and AC verification. The internal 600Ω
terminating resistor has a tolerance of ±20%. The device is
intended to operate from only the low battery during this
mode.
Architecture
When the forward loop back mode is initiated internal
switches connect a 600Ω load across the outputs of the Tip
and Ring amplifiers.
TIP
Three very distinct actions occur when the devices detects a
ring trip. First, the DET output is latched low. The latching
mechanism eliminates the need for software filtering of the
detector output. The latch is cleared when the operating
mode is changed externally. Second, the VRS input is
disabled, removing the ring signal from the line. Third, the
device is internally forced to the forward active mode.
FIGURE 11. FORWARD LOOP BACK INTERNAL TERMINATION
Power Dissipation
DC Verification
The power dissipation during ringing is dictated by the load
driving requirements and the ringing waveform. The key to valid
power calculations is the correct definition of average and RMS
currents. The average current defines the high battery supply
current. The RMS current defines the load current.
When the internal signal path is provided, DC current will
flow from Tip to Ring. The DC current will force DET low,
indicating the presence of loop current. In addition, the ALM
output will also go low. This does not indicate a thermal
alarm condition. Rather, proper logic operation is verified in
the event of a thermal shutdown. In addition to verifying
device functionality, toggling the logic outputs verifies the
interface to the system controller.
The cadence provides a time averaging reduction in the
peak power. The total power dissipation consists of ringing
power, Pr , and the silent interval power, Ps .
tr
ts
P RNG = P r × -------------- + P s × -------------t +t
t +t
r
s
r
(EQ. 35)
s
The terms tR and tS represent the cadence. The ringing
interval is tR and the silent interval is tS . The typical cadence
ratio tR :tS is 1:2.
The quiescent power of the device in the ringing mode is
defined in Equation 36.
P r ( Q ) = V BH × I BHQ + V BL × I BLQ + V CC × I CCQ
(EQ. 36)
The total power during the ringing interval is the sum of the
quiescent power and loading power:
2
V RMS
P r = P r ( Q ) + V BH × I AVG – -----------------------------------------Z
+R
REN
(EQ. 37)
LOOP
For sinusoidal waveforms, the average current, IAVG , is
defined in Equation 38.
V RMS × 2
2
I AVG =  --- ----------------------------------------- π Z
+R
REN
(EQ. 38)
LOOP
The silent interval power dissipation will be determined by
the quiescent power of the selected operating mode.
4-13
TIP AMP
600Ω
RING AMP
RING
AC Verification
The entire AC loop of the device is active during the forward
loop back mode. Therefore a 4-wire to 4-wire level test
capability is provided. Depending on the transhybrid balance
implementation, test coverage is provided by a one or two
step process.
System architectures which cannot disable the transhybrid
function would require a two step process. The first step
would be to send a test tone to the device while on hook and
not in forward loop back mode. The return signal would be
the test level times the gain RF /RA of the transhybrid
amplifier. Since the device would not be terminated,
cancellation would not occur. The second step would be to
program the device to FLB and resend the test tone. The
return signal would be much lower in amplitude than the first
step, indicating the device was active and the internal
termination attenuated the return signal.
System architectures which disable the transhybrid function
would achieve test coverage with a signal step. Once the
transhybrid function is disable, program the device for FLB
and send the test tone. The return signal level is determined
by the 4-wire to 4-wire gain of the device.
HC55185
Tip Open
Functionality
Overview
The tip open mode (110) is intended for compatibility for
PBX type interfaces. Used during idle line conditions, the
device does not provide transmission. Loop supervision is
provided by either the switch hook detector (E0 = 1) or the
ground key detector (E0 = 0). The ground key detector will
be used in most applications. The device may be operated
from either high or low battery.
Functionality
During tip open operation, the Tip switch is disabled and the
Ring switch is enabled. The minimum Tip impedance is
30kΩ. The only active path through the device will be the
Ring switch.
The logic control is independent of the operating mode
decode. Independent logic control provides the most
flexibility and will support all application configurations.
When changing device operating states, battery switching
should occur simultaneously with or prior to changing the
operating mode. In most cases, this will minimize overall
power dissipation and prevent glitches on the DET output.
The only external component required to support the battery
switch is a diode in series with the VBH supply lead. In the
event that high battery is removed, the diode allows the
device to transition to low battery operation.
Low Battery Operation
Power Denial
All off hook operating conditions should use the low battery.
The prime benefit will be reduced power dissipation. The
typical low battery for the device is -24V. However this may
be increased to support longer loop lengths or high loop
current requirements. Standby conditions may also operate
from the low battery if MTU compliance is not required,
further reducing standby power dissipation.
Overview
High Battery Operation
The power denial mode (111) will shutdown the entire device
except for the logic interface. Loop supervision is not
provided. This mode may be used as a sleep mode or to
shut down in the presence of a persistent thermal alarm.
Switching between high and low battery will have no effect
during power denial.
Other than ringing, the high battery should be used for
standby conditions which must provide MTU compliance.
During standby operation the power consumption is typically
85mW with -100V battery. If ringing requirements do not
require full 100V operation, then a lower battery will result in
lower standby power.
Functionality
High Voltage Decoupling
During power denial, both the Tip and Ring amplifiers are
disabled, representing high impedances. The voltages at
both outputs are near ground.
The 100V rating of the device will require a capacitor of
higher voltage rating for decoupling. Suggested decoupling
values for all device pins are 0.1µF. Standard surface mount
ceramic capacitors are rated at 100V. For applications driven
at low cost and small size, the decoupling scheme shown
below could be implemented.
In keeping with the MTU characteristics of the device, Ring
will not exceed -56V when operating from the high battery.
Though MTU does not apply to tip open, safety requirements
are satisfied.
Thermal Shutdown
In the event the safe die temperature is exceeded, the ALM
output will go low and DET will go high and the part will
automatically shut down. When the device cools, ALM will
go high and DET will reflect the loop status. If the thermal
fault persists, ALM will go low again and the part will shut
down. Programming power denial will permanently
shutdown the device and stop the self cooling cycling.
0.22µ
0.22µ
VBL
VBH
HC5518X
Battery Switching
FIGURE 12. ALTERNATE DECOUPLING SCHEME
Overview
The integrated battery switch selects between the high
battery and low battery. The battery switch is controlled
with the logic input BSEL. When BSEL is a logic high, the
high battery is selected and when a logic low, the low
battery is selected. All operating modes of the device will
operate from high or low battery except forward loop back.
4-14
It is important to place the external diode between the VBH
pin and the decoupling capacitor. Attaching the decoupling
capacitor directly to the VBH pin will degrade the reliability of
the device. Refer to Figure 12 for the proper arrangement.
This applies to both single and stacked and decoupling
arrangements.
If VBL and VBH are tied together to override the battery
switch function, then the external diode is not needed and
the decoupling may be attached directly to VBH.
HC55185
Uncommitted Switch
Basic Application Circuit
CPS1
Overview
CPS2
The uncommitted switch is a three terminal device designed
for flexibility. The independent logic control input, SWC,
allows switch operation regardless of device operating
mode. The switch is activated by a logic low. The positive
and negative terminals of the device are labeled SW+ and
SW- respectively.
D1
CPS3
VCC
RP1
VBL
VBH
U1
TIP
HC55185
Relay Driver
RP2
RING
The uncommitted switch may be used as a relay driver by
connecting SW+ to the relay coil and SW- to ground. The
switch is designed to have a maximum on voltage of 0.6V
with a load current of 45mA.
SW+
+5V
CRT
SW-
RRT
RTD
RIL
RD
ILIM
SW+
SWC
SW-
CDC
CPOL
POL
TL
AGND
Since the device provides the ringing waveform, the relay
functions which may be supported include subscriber
disconnect, test access or line interface bypass. An external
snubber diode is not required when using the uncommitted
switch as a relay driver.
RING
TEST
LOAD
SW+
SW-
SWC
FIGURE 14. TEST LOAD SWITCHING
The diode in series with the test load blocks current from
flowing through the uncommitted switch when the polarity of
the Tip and Ring terminals are reversed. In addition to the
reverse active state, the polarity of Tip and Ring are reversed
for half of the ringing cycle. With independent logic control
and the blocking diode, the uncommitted switch may be
continuously connected to the Tip and Ring terminals.
4-15
CTX
CFB
VFB
BSEL
E0
F1
F2
ALM
BGND
TABLE 4. BASIC APPLICATION CIRCUIT COMPONENT LIST
COMPONENT
TIP
RS
-IN
FIGURE 15. HC55185 BASIC APPLICATION CIRCUIT
Test Load
The switch may be used to connect test loads across Tip
and Ring. The test loads can provide external test
termination for the device. Proper connection of the
uncommitted switch to Tip and Ring is shown below.
VTX
DET
RTL
FIGURE 13. EXTERNAL RELAY SWITCHING
CRS
F0
CDC
VCC
VRS
SWC
RSH
RELAY
CRX
VRX
U1 - Ringing SLIC
VALUE
TOL
RATING
HC55185
N/A
N/A
RTL
18.7kΩ
1%
0.1W
RRT
23.7kΩ
1%
0.1W
RSH
49.9kΩ
1%
0.1W
RIL
71.5kΩ
1%
0.1W
RS
66.5kΩ
1%
0.1W
CRX , CRS , CTX , CRT , CPOL
0.47µF
20%
10V
CDC, CFB
4.7µF
20%
10V
CPS1
0.1µF
20%
>100V
CPS2 , CPS3
0.1µF
20%
100V
D1
1N400X type with breakdown > 100V.
RP1 , RP2
Standard applications will use ≥ 49Ω per side. Protection resistor
values are application dependent and will be determined by
protection requirements.
Design Parameters: Ring Trip Threshold = 76mAPEAK , Switch
Hook Threshold = 12mA, Loop Current Limit = 24.6mA, Synthesize
Device Impedance = (3*66.5kΩ)/400 = 498.8Ω, with 49.9Ω
protection resistors, impedance across Tip and Ring
terminals = 599Ω. Transient current limit = 95mA.
HC55185
Pin Descriptions
PLCC
SYMBOL
DESCRIPTION
1
TIP
2
BGND
3
VBL
Low battery supply connection.
4
VBH
High battery supply connection for the most negative battery.
5
SW+
Uncommitted switch positive terminal.
6
SW-
Uncommitted switch negative terminal.
7
SWC
Switch control input. This TTL compatible input controls the uncommitted switch, with a logic “0” enabling the switch and
logic “1” disabling the switch.
8
F2
Mode Control Input - MSB. F2-F0 for the TTL compatible parallel control interface for controlling the various modes of
operation of the device.
9
F1
Mode control input.
10
F0
Mode control input.
11
E0
Detector Output Selection Input. This TTL input controls the multiplexing of the SHD (E0 = 1) and GKD (E0 = 0)
comparator outputs to the DET output based upon the state at the F2-F0 pins (see the Device Operating Modes table
shown on page 2).
12
DET
Detector Output - This TTL output provides on-hook/off-hook status of the loop based upon the selected operating mode.
The detected output will either be switch hook, ground key or ring trip (see the Device Operating Modes table shown on
page 2).
13
ALM
Thermal Shutdown Alarm. This pin signals the internal die temperature has exceeded safe operating temperature
(approximately 175oC) and the device has been powered down automatically.
14
AGND
Analog ground reference. This pin should be externally connected to BGND.
15
BSEL
Selects between high and low battery, with a logic “1” selecting the high battery and logic “0” the low battery.
16
TL
17
POL
External capacitor on this pin sets the polarity reversal time.
18
VRS
Ringing Signal Input - Analog input for driving 2-wire interface while in Ring Mode.
19
VRX
Analog Receive Voltage - 4-wire analog audio input voltage. AC couples to CODEC.
20
VTX
Transmit Output Voltage - Output of impedance matching amplifier, AC couples to CODEC.
21
VFB
Feedback voltage for impedance matching. This voltage is scaled to accomplish impedance matching.
22
-IN
23
VCC
Positive voltage power supply, usually +5V.
24
CDC
DC Biasing Filter Capacitor - Connects between this pin and VCC.
25
RTD
Ring trip filter network.
26
ILIM
Loop Current Limit programming resistor.
27
RD
Switch hook detection threshold programming resistor.
28
RING
TIP power amplifier output.
Battery Ground - To be connected to zero potential. All loop current and longitudinal current flow from this ground.
Internally separate from AGND but it is recommended that it is connected to the same potential as AGND.
Programming pin for the transient current limit feature, set by an external resistor to ground.
Impedance matching amplifier summing node.
RING power amplifier output.
4-16
HC55185
Plastic Leaded Chip Carrier Packages (PLCC)
0.042 (1.07)
0.048 (1.22)
PIN (1) IDENTIFIER
N28.45 (JEDEC MS-018AB ISSUE A)
0.042 (1.07)
0.056 (1.42)
0.004 (0.10)
C
0.025 (0.64)
R
0.045 (1.14)
0.050 (1.27) TP
C
L
D2/E2
C
L
E1 E
D2/E2
VIEW “A”
A1
A
D1
D
0.020 (0.51) MAX
3 PLCS
0.020 (0.51)
MIN
28 LEAD PLASTIC LEADED CHIP CARRIER PACKAGE
INCHES
MILLIMETERS
SYMBOL
MIN
MAX
MIN
MAX
NOTES
A
0.165
0.180
4.20
4.57
-
A1
0.090
0.120
2.29
3.04
-
D
0.485
0.495
12.32
12.57
-
D1
0.450
0.456
11.43
11.58
3
D2
0.191
0.219
4.86
5.56
4, 5
E
0.485
0.495
12.32
12.57
-
E1
0.450
0.456
11.43
11.58
3
E2
0.191
0.219
4.86
5.56
4, 5
N
28
28
6
Rev. 2 11/97
SEATING
-C- PLANE
0.026 (0.66)
0.032 (0.81)
0.045 (1.14)
MIN
0.013 (0.33)
0.021 (0.53)
0.025 (0.64)
MIN
VIEW “A” TYP.
NOTES:
1. Controlling dimension: INCH. Converted millimeter dimensions are
not necessarily exact.
2. Dimensions and tolerancing per ANSI Y14.5M-1982.
3. Dimensions D1 and E1 do not include mold protrusions. Allowable
mold protrusion is 0.010 inch (0.25mm) per side. Dimensions D1
and E1 include mold mismatch and are measured at the extreme
material condition at the body parting line.
4. To be measured at seating plane -C- contact point.
5. Centerline to be determined where center leads exit plastic body.
6. “N” is the number of terminal positions.
All Intersil semiconductor products are manufactured, assembled and tested under ISO9000 quality systems certification.
Intersil semiconductor products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design and/or specifications at any time without notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and
reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result
from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries.
For information regarding Intersil Corporation and its products, see web site www.intersil.com
Sales Office Headquarters
NORTH AMERICA
Intersil Corporation
P. O. Box 883, Mail Stop 53-204
Melbourne, FL 32902
TEL: (321) 724-7000
FAX: (321) 724-7240
4-17
EUROPE
Intersil SA
Mercure Center
100, Rue de la Fusee
1130 Brussels, Belgium
TEL: (32) 2.724.2111
FAX: (32) 2.724.22.05
ASIA
Intersil (Taiwan) Ltd.
7F-6, No. 101 Fu Hsing North Road
Taipei, Taiwan
Republic of China
TEL: (886) 2 2716 9310
FAX: (886) 2 2715 3029
Similar pages