Melexis MLX91206LDCCAL-003RE Imc-hallcurrent sensor (triaxistechnology) Datasheet

MLX91206
®
®
IMC-Hall Current Sensor (Triaxis Technology)
Features and Benefits
Application Examples
 Triaxis® Technology
 Very high sensitivity due to Integrated
Magnetic Concentrator (IMC-Hall®)
 Programmable high speed current sensor IC
 Wideband: DC to 90kHz
 Short response time
 Programmable linear transfer characteristic
 Selectable
 analog ratiometric output
 PWM output with 12 bit resolution
 Thermometer output
 17 bit ID Number
 SOIC8 package RoHS compliant
 Lead free component, suitable for lead free
soldering profile 260°C (target), MSL3






DC/AC (inverter) converter
DC/DC switched mode power supply
Battery Management
Smart fuse (over-current detection)
BLDC motor (phase current)
AC/DC Converters
Ordering Information
Product
Code
MLX91206
MLX91206
MLX91206
MLX91206
MLX91206
MLX91206
MLX91206
MLX91206
MLX91206
Temperature
Code
L (-40°C to 150°C)
L (-40°C to 150°C)
L (-40°C to 150°C)
L (-40°C to 150°C)
L (-40°C to 150°C)
L (-40°C to 150°C)
L (-40°C to 150°C)
L (-40°C to 150°C)
L (-40°C to 150°C)
Package
Code
DC (SOIC)
DC (SOIC)
DC (SOIC)
DC (SOIC)
DC (SOIC)
DC (SOIC)
DC (SOIC)
DC (SOIC)
DC (SOIC)
Ordering
Option Code
CAL-001
CAL-002
CAL-003
CAH-001
CAH-002
CAH-003
CAH-004
(1)
CAH-021
(2)
CAH-104
Packing
form Code
TU (Tube) / RE (Reel)
Sensitivity Range
(Typ.)
460-700mV/mT (580mV/mT)
300-470mV/mT (380mV/mT)
200-310mV/mT (250mV/mT)
210-330mV/mT (270mV/mT)
130-220mV/mT (170mV/mT)
80-140mV/mT (110mV/mT)
60-110mV/mT (77.5mV/mT)
210-330mV/mT (270mV/mT)
0.5-5%DC/mT
(1) The MLX91206 sensor is in disabledratiometry mode by default for this version
(2) The MLX91206 sensor is in PWM mode by default for this version
Ordering example: MLX91206LDC-CAL-001-RE
1 Functional Diagram
3.3V core
TEMPOUT
Thermometer
3.3V
ana
Voltage
Regulator
&
Rev.Pol.
protection
3.3V
dig
VDIG
VDD
VSS
Oscillator
Clock
1 MHz
Generator
fs = 1MHz
Input data rate
fs = 1MHz
4Phase
Switch
Box
fo = 250 kHz or 25 kHz
Output data rate
Integrating
P2P
DIDO
G = 15 … 239
fi = 250kHz or 25kHz
Intermediate data rate
G = 0.4 … 1
Clamping
LPF
S&H
G=4
5V ratiometric
output
Output
Buffer
OUT
ADC
DAC
Hall
Bias
PWM Logic
3 bits
TC1ST[6:0]
HallSensors
selection
RG[2:0]
10 bits
2 bits
PLATEPOL
FG[9:0]
TC2ND_COLD[4:0]
OFFSETDRIFT_HOT[5:0]
TC2ND_HOT[4:0]
OFFSETDRIFT_COLD[5:0]
Sensitivity
trimming
12 bits
6 bits
FILTCODE[1:0] XA[11:0] CLAMPLOW[2:0]
Digital
Ratiometry
MUST0
CLAMPHIGH[2:0]
MUST1
DIGITAL + EEPROM
Rough Gain
Fine Gain
Offset
Compensation
Polarity
selection
Bandwidth
Voq adjust
TESTOUT
Figure 1: Block diagram
3901091206
Rev 043
Page 1
Datasheet MLX91206
April 2016
®
MLX91206
®
IMC-Hall Current Sensor (Triaxis Technology)
2 General Description
The MLX91206 is a monolithic sensor IC featuring the Triais® Hall technology. Conventional planar Hall
technology is only sensitive to the flux density applied orthogonally to the IC surface. The IMC-Hall® current
sensor is sensitive to the flux density applied parallel to the IC surface. This is obtained through an Integrated
Magneto-Concentrator (IMC-Hall®) which is deposited on the CMOS die (as an additional back-end step).
The IMC-Hall® current sensor is automotive qualified.
The product is a single chip Hall sensor which provides an output signal which is proportional to the flux
density applied horizontally and is therefore suitable for current measurement. It is ideally used as an open
loop current sensor for PCB mounting. (see figure 2). It features small size application design and a simple
construction for various current ranges.
The transfer characteristic of the MLX91206 is programmable (offset, gain, clamping levels, diagnostic
functions…). The output is selectable between analog and PWM. The linear analog output is used for
application where a very fast response (<10 sec) is required, whereas the PWM output is used for
application where low speed but high output signal robustness is required.
Figure 2: Typical application of MLX91206
3901091206
Rev 043
Page 2
Datasheet MLX91206
April 2016
®
MLX91206
®
IMC-Hall Current Sensor (Triaxis Technology)
Table of Contents
1 Functional Diagram................................................................................................................................................................................ 1
2 General Description ............................................................................................................................................................................... 2
3 Glossary of Terms ................................................................................................................................................................................. 4
4 Absolute Maximum Ratings ................................................................................................................................................................... 4
5 Pin Definitions and Descriptions ............................................................................................................................................................ 4
6 General Electrical Specifications ............................................................................................................................................................ 5
7 Magnetic specification ........................................................................................................................................................................... 6
7.1 25 mT version (marking xxH) .......................................................................................................................................................... 6
7.2 10 mT version (marking xxL) ......................................................................................................................................................... 6
8 Analog output specification .................................................................................................................................................................... 7
8.1 Timing specification ........................................................................................................................................................................ 7
8.2 Accuracy specification .................................................................................................................................................................... 7
8.3 Remarks to the achievable accuracy .............................................................................................................................................. 7
9 PWM output specification ...................................................................................................................................................................... 8
9.1 Timing specification for the PWM output ......................................................................................................................................... 8
9.2 Magnetic specification for the PWM output ..................................................................................................................................... 9
9.3 Accuracy specification transfer characteristic PWM ........................................................................................................................ 9
10 Thermometer output specification ........................................................................................................................................................ 9
11 Programmable items .......................................................................................................................................................................... 10
11.1 Parameter table .......................................................................................................................................................................... 10
11.2 Output mode configuration (DSPMODE, OUTMODE) ................................................................................................................ 11
11.3 Output impedance mode (DIAGINFAULT) .................................................................................................................................. 11
11.4 Reference edge (REFEDGE) – only in PWM mode .................................................................................................................... 11
11.5 PWM/switch mode (SWITCH)..................................................................................................................................................... 11
11.6 Platepol (PLATEPOL)................................................................................................................................................................. 12
11.7 Sensitivity programming (ROUGHGAIN, FINEGAIN) .................................................................................................................. 12
11.8 Offset / output quiescent voltage programming (XA, YA) ............................................................................................................ 13
11.9 Clamping level programming (CLAMPLOW, CLAMPHIGH) ........................................................................................................ 13
11.10 Bandwidth and filter programming (FILTCODE) ........................................................................................................................ 14
11.11 Power limitation / PWM rise and fall time (OUTSLOPE)............................................................................................................ 15
11.12 PWM Mode duty cycle definition (DCDEF) ............................................................................................................................... 16
11.13 Output ratiometry (RATIODIS) .................................................................................................................................................. 16
11.14 Sensitivity and temperature drift programming (TC1ST, TC2ND_COLD, TC2ND_HOT) ........................................................... 16
11.15 Offset temperature drift programming (OFFDRIFT_COLD, OFFDRIFT_HOT) .......................................................................... 16
11.16 Product Identification (MLXID, CSTID)...................................................................................................................................... 17
12 Application information....................................................................................................................................................................... 18
12.1 Low current measurement up to ±2 A ......................................................................................................................................... 18
12.2 Medium current up to ±30 A ....................................................................................................................................................... 18
12.3 High current measurement up to ±600 A .................................................................................................................................... 18
13 Recommended Application Diagrams ................................................................................................................................................ 19
13.1 Resistor and capacitor values ..................................................................................................................................................... 19
13.2 Fast analog application, pull-down resistor for diagnostic low ..................................................................................................... 19
13.3 Fast analog application, pull-up resistor for diagnostic high ........................................................................................................ 20
13.4 Robust PWM application, (pull-up load only) .............................................................................................................................. 20
14 Standard information regarding manufacturability of Melexis products with different soldering processes .......................................... 21
15 ESD Precautions ............................................................................................................................................................................... 21
16 Package Information .......................................................................................................................................................................... 22
16.1 SOIC8 Package dimensions ....................................................................................................................................................... 22
16.2 SOIC8 Pinout and Marking ......................................................................................................................................................... 22
16.3 SOIC8 Hall plate position............................................................................................................................................................ 23
16.4 IMC Position and sensors active measurement direction ............................................................................................................ 23
17 Related documents and tools............................................................................................................................................................. 24
17.1 Related documents .................................................................................................................................................................... 24
17.2 Related software ........................................................................................................................................................................ 24
17.3 Related hardware ....................................................................................................................................................................... 24
18 Disclaimer.......................................................................................................................................................................................... 25
3901091206
Rev 043
Page 3
Datasheet MLX91206
April 2016
MLX91206
®
®
IMC-Hall Current Sensor (Triaxis Technology)
3 Glossary of Terms
Tesla
TC
NC
PWM
%DC
ADC
DAC
LSB
MSB
DNL
INL
IMC
PTC
Units for the magnetic flux density, 1 mT = 10 Gauss
Temperature Coefficient in ppm/deg C
Not Connected
Pulse Width Modulation
Duty Cycle of the output signal i.e. T ON /(TON + TOFF)
Analog to Digital Converter
Digital to Analog Converter
Least Significant Bit
Most Significant Bit
Differential Non Linearity
Integral Non Linearity
Integrated Magneto Concentrator (IMC)
Programming Through Connector
4 Absolute Maximum Ratings
Parameter
Positive Supply Voltage (overvoltage)
Reverse Supply Voltage Protection
Positive Output Voltage
Symbol
Vdd
Output Current
Reverse Output Voltage
Reverse Output Current
Operating Ambient Temperature Range
Storage Temperature Range
Magnetic Flux Density
Iout
Value
+20
-10
+10
+14 (200 s max, TA = +25°C)
±300
-0.3
-50
-40 to +150
-55 to +165
±0.2
TA
TS
Units
V
V
V
mA
V
mA
°C
°C
T
Table 1: Absolute maximum ratings
Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute maximum
rated conditions for extended periods may affect device reliability.
5 Pin Definitions and Descriptions
Pin №
1
2
3
4
5
6
7
8
Name
VDD
VSS
VDIG
MUST1
OUT / PWM
TESTOUT
MUST0
TEMPOUT
Type
Supply
Ground
Supply
Digital
Analog/Digital
Digital
Digital
Analog
Function
Supply Voltage
Supply Voltage
Digital supply voltage, 3.3 V, internal regulated
Test and Factory calibration
Current sensor output
Test and Factory calibration
Test and Factory calibration
Temperature Sensor Output
Table 2: Pin definition and description
It is recommended to connect the unused pins to the Ground (see section 16) for optimal EMC results.
3901091206
Rev 043
Page 4
Datasheet MLX91206
April 2016
MLX91206
®
®
IMC-Hall Current Sensor (Triaxis Technology)
6 General Electrical Specifications
Operating Parameters : TA = -40 to 125degC, Vdd = 4.5 V to 5.5 V, Iout = -2 mA to +2 mA, recommended
application diagram in section 16, unless otherwise specified. All mentioned component values can have a
±20% tolerance
Parameter
Nominal Supply Voltage
Supply Current
Symbol
Vdd
Idd
Test Conditions
Min
4.5
W/o output load & TA = -40 to 150oC
- ROUGHGAIN ≤ 3
- ROUGHGAIN > 3
Output Current
Output Resistance
Output Capacitive Load
Iout
Output Short Circuit Current
Ishort
Leakage current
Ileak
Output Voltage Swing (Linear
Range)
Vout_pd
pull down ≥ 10 kΩ
Vout_pu
pull up ≥ 10 kΩ
Vout_HiZ_pu
pull-up RL ≤ 30 kΩ
Vout_HiZ_pd
pull-down RL ≤ 30 kΩ
OUT with pull-down RL ≤ 10 kΩ (3)
5
5
97
OUT with pull-up RL ≤ 30 kΩ (3)
OUT with pull-down RL ≤ 30 kΩ (3)
OUT with pull-up RL ≤ 30 kΩ (3)
Vdd_uvd
Detected Voltage (Low to High)
Vdd_uvh
Hysteresis
Vdd_ovd1
Detected Voltage (Low to High)
Vdd_ovh1
Hysteresis
Vdd_ovd2
Detected Voltage (Low to High)
Vdd_ovh2
Hysteresis
Clamp_lo
Trimming Range
Clamp_hi
Trimming Range
97
Vout = 50% Vdd, RL = 5kΩ
Analog Mode
PWM Mode
Output shorted to Vdd- Permanent
Output shorted to Vss - Permanent
High impedance mode (2)
Cload
High-impedance mode levels(2)
BrokenVss Output
-2
Levels(2)
BrokenVdd Output Levels(2)
Under-voltage detection (2) (4)
Over-voltage detection mode 1
(2) (4)
Over-voltage detection mode 2
(2) (4)
Clamped Output Level
5
0
Typ
5
Max
5.5
Units
V
7
9
10
12
mA
mA
2
1
5
10
50
10
50
Not Destroyed
Not Destroyed
5
mA

nF
nF
95
95
3
3
3
97
3.15
0.25
7.8
0.8
6.7
0.05
5 (1)
90
3.3
0.3
3.45
0.4
9.5
1.6
7.6
0.5
10
95 (1)
uA
%Vdd
%Vdd
%Vdd
%Vdd
%Vdd
%Vdd
%Vdd
%Vdd
V
V
V
V
V
V
%Vdd
%Vdd
Table 3: General electrical parameter
(1)
(2)
(3)
(4)
Factory programmed clamping level
Refer to chapter Self-diagnostic, table 21.
Valid for TEMPOUT with pull-up (min. 30kΩ), pull-down (min. 30kΩ) or not connected
According to the figure below
Vout
Hysteresis
Detected
Voltage
Vdd
Figure “Detected voltage and hysteresis definitions”
3901091206
Rev 043
Page 5
Datasheet MLX91206
April 2016
MLX91206
®
®
IMC-Hall Current Sensor (Triaxis Technology)
7 Magnetic specification
7.1 25 mT version (marking xxH)
Operating Parameters TA = -40 to 125degC, Vdd = 4.5 V to 5.5 V, unless otherwise specified.
Parameter
Nominal Field Range
Operational Field Range
Symbol
Bnom
(1)
Linearity Error
Max
+20
Units
mT
Programmable Sensitivity
(2)
Sensitivity programming Resolution
Min
-20
-25
+25
mT
Nominal Field Range (25°C)
-0.5
+0.5
%FS
Operational Field Range (25°C)
-0.75
+0.75
%FS
Br
B = Bop
-25
+25
uT
S
B = Bop , Analog Mode
80
330
mV/mT
Sres
B = Bop
Bop
NL
Hysteresis, remanent Field
Test Conditions
Typ
0.1
%
Table 4: Magnetic specification 25mT version (high-field version)
(1) Above 25 mT, the IMC starts saturating yielding to an increase of the linearity error.
(2) The specified programmable sensitivity range is covered by 5 different versions (option codes)
Option code (25mT)
CAH-001
CAH-002
CAH-003
CAH-004
CAH-021
Programmed Sensitivity
270mV/mT
170mV/mT
110mV/mT
77.5mV/mT
270mV/mT
Sensitivity Range
210 - 330mV/mT
130 - 220mV/mT
80 - 140mV/mT
60 - 110mV/mT
210 - 330mV/mT
7.2 10 mT version (marking xxL)
Operating Parameters TA = -40 to 125degC, Vdd = 4.5 V to 5.5 V (unless otherwise specified)
Parameter
Nominal Field Range
Symbol
Bnom
Operational Field Range (3)
Bop
Linearity Error
NL
Test Conditions
Min
-7.5
Max
+7.5
Units
mT
-10
+10
mT (2)
-0.5
+0.5
%FS
Operational Field Range (25°C) -0.75
+0.75
%FS
Nominal Field Range (25°C)
Typ
Hysteresis, remanent Field
Br
B = Bop
-10
+10
uT
Programmable Sensitivity
S
B = Bop , Analog Mode
200
700
mV/mT
Sres
B = Bop
(4)
Sensitivity programming Resolution
0.1
%
Table 5: Magnetic specification 10mT version (low-field version)
(3) Above 10 mT, the IMC starts saturating yielding to an increase of the linearity error.
(4) The specified programmable sensitivity range is covered by 3 different versions (option codes)
Option code (10mT)
CAL-001
CAL-002
CAL-003
3901091206
Rev 043
Programmed Sensitivity
580mV/mT
380mV/mT
250mV/mT
Page 6
Sensitivity Range
460-700mV/mT
300-470mV/mT
200-310mV/mT
Datasheet MLX91206
April 2016
MLX91206
®
®
IMC-Hall Current Sensor (Triaxis Technology)
8 Analog output specification
8.1 Timing specification
Operating Parameters TA = -40 to 125degC, Vdd = 4.5 V to 5.5 V (unless otherwise specified)
Parameter
Step Response Time
Bandwidth
Power on Delay
Ratiometry Cut-off Frequency
Symbol
Tresp
BW
TPOD
Test Conditions
Voq ± 2 V
BW =Range
100 kHz – No filter
Full
Vout =100% of FS
(BW = 100 Hz)
(BW = 1000 Hz)
(BW = 10 kHz)
(BW = 100 kHz – No filter)
Min
50
Fratio
Typ
8
70
Max
10
90
Units
μs
kHz
100
10
5
5
ms
ms
ms
ms
250
Hz
Table 6: Timing specification high speed analog output
8.2 Accuracy specification
Operating Parameters TA = -40 to 125degC, Vdd = 4.5 V to 5.5 V (unless otherwise specified)
Parameter
Thermal Offset Drift
Thermal Offset Drift(1)
Symbol
ΔTVoq
ΔTVoq
Test Conditions
Thermal Sensitivity Drift
TC
RMS Output noise
Nrms
S = 6 %Vdd/mT (= 300 mV/mT @
Vdd=5V)
Voq Ratiometry
ΔVoq
Voq = 50%Vdd
ΔVdd = 10%Vdd
Voq Drift – Supply Related(1)
ΔVoq
Sensitivity Ratiometry
Clamped output accuracy
Min
-0.4
-20
Max
+0.4
20
Units
%Vdd
mV
+1.5
%S
0.1
%Vdd
10.2
%
Voq = 50%Vdd (Vdd Nominal = 5V) -5
ΔVdd = 10%Vdd
5
mV
ΔS
ΔVdd = 10%Vdd
B = Bop
9.8
10.2
%
Clamp_lo
Clamp_hi
Trimming range: 5-10%Vdd
Trimming range: 90-95%Vdd
-1
1
%Vdd
-1.5
9.8
Typ
Table 7: Accuracy specific parameter analog output
(1) Applies to CAH-021 version
8.3 Remarks to the achievable accuracy
The achievable target accuracy is dependent on user’s end-of-line calibration. The resolution for the offset
and offset drift calibration is better than 0.1%Vdd. Trimming capability is higher than the measurement
accuracy. End-user calibration can increase the accuracy of the system.
3901091206
Rev 043
Page 7
Datasheet MLX91206
April 2016
MLX91206
®
®
IMC-Hall Current Sensor (Triaxis Technology)
9 PWM output specification
9.1 Timing specification for the PWM output
Operating Parameters TA = -40 to 125degC, Vdd = 4.5 V to 5.5 V (unless otherwise specified)
Parameter
Main Oscillator Frequency
Symbol
FOSC
PWM Output Frequency
FPWM
Tick Time (resolution in time
domain)
tTICK
PWM Output Resolution
R(PWM)
PWM Jitter (1 Sigma)
Output Rise Time
(10%-90%)
Output Fall Time
(90%-10%)
Clamped Output Level
Power-on delay
Test Conditions
Tolerance  10%
Min
900
Typ
1024
Max
1100
Units
kHz
110
125
140
Hz
1
µs
12 Bit, Theoretical Jitter free
0.025
%DC
J (PWM)
FILTCODE = 5
(70 Hz Digital LowPass Filter)
0.01
%DC
(1 Sigma)
tRISEOD
Push-pull mode
RL = 4.7 k to 5 V, CL = 10 nF
OUTSLOPE = 0
11
µs
OUTSLOPE = 1
7
μs
OUTSLOPE = 2
4
μs
OUTSLOPE = 3
2.5
μs
Push-pull or open-drain mode
RL = 4.7 k to 5 V, CL = 10 nF
OUTSLOPE = 0
14
µs
OUTSLOPE = 1
8
μs
OUTSLOPE = 2
4.5
μs
OUTSLOPE = 3
2.5
μs
TFALLOD
Clamp_lo
Programmable
1
10
%DC
Clamp_hi
Programmable
90
99
%DC
11
ms
TPOD
Table 8: Timing specification for the PWM output
3901091206
Rev 043
Page 8
Datasheet MLX91206
April 2016
MLX91206
®
®
IMC-Hall Current Sensor (Triaxis Technology)
9.2 Magnetic specification for the PWM output
Operating Parameters TA = -40 to 125degC, Vdd = 4.5 V to 5.5 V, unless otherwise specified.
Parameter
Nominal Field Range
Operational Field Range
Symbol
Bnom
Test Conditions
Max
+20
Units
mT
-25
+25
mT
Nominal Field Range (25°C)
-0.5
+0.5
%FS
Operational Field Range (25°C)
-0.75
+0.75
%FS
Bop
(1)
Linearity Error
NL
Min
-20
Typ
Hysteresis, remanent Field
Br
B = Bop
-25
+25
uT
Programmable Sensitivity
S
B = Bop
0.5
5
%DC/mT
Sensitivity programming Resolution
Sres
B = Bop
0.1
%
Table 9: Magnetic specification 25mT version (high-field version)
(1) Above 25 mT, the IMC starts saturating yielding to an increase of the linearity error.
9.3 Accuracy specification transfer characteristic PWM
Operating Parameters TA = -40 to 125degC, Vdd = 5.0 V (unless otherwise specified), S = 4%DC/mT
Parameter
Thermal Offset Drift
Thermal Sensitivity Drift
Symbol
ΔTVoq
TC
Test Conditions
Min
-0.4
-150
Typ
Max
+0.4
+150
Units
%DC
ppm/°C
Table 10: Accuracy specific parameter PWM output
10 Thermometer output specification
The thermometer output voltage is in the range from 367mV to 2930mV for temperatures ranging from -40 to
150degC. The accuracy is better than 5degC. The pin shall be able to sustain a low impedance connection to
maximum 14V. This output is not ratiometric.
Parameter
Offset
Slope
Accuracy
Load capacitor
Output current
Symbol
T35
Tslope
Tacc
CloadTherm
Iouttherm
Test Conditions
Output voltage with T = 35degC
3-bit adjustment
Min
Typ
1.38
13.5
-5
External through bonding wire
1
-0.1
Max
5
50
+0.1
Units
V
mV/degC
degC
nF
mA
Table 11: Thermometer output specification
3901091206
Rev 043
Page 9
Datasheet MLX91206
April 2016
®
MLX91206
®
IMC-Hall Current Sensor (Triaxis Technology)
11 Programmable items
11.1 Parameter table
Customers can re-program the parameters described in the table below by using the Melexis PTC-04
hardware and the Product Specific Functions (PSF) libraries provided by Melexis. We recommend using the
latest version of the PSF and the latest version of the firmware with a communication speed of 10kbps
(limited by a maximum output capacitor of 50nF). Software and firmware are available on the softdist platform
(see contact details on page 25 to request an account).
Parameter
Bits
Factory Setting Comment
DSPMODE
1
0
Selection analog or PWM output
OUTMODE
1
1
Capacitive load selection in analog mode
Push pull or open drain output drive in PWM mode
N/A
Output impedance setting
DIAGINFAULT
1
0
Not used in analog mode
REFEDGE
1
0
Diagnostic level & reference edge
Not used in analog mode
SWITCH
1
N/A
PWM or SWITCH output selection
0
(1)
Change of sensitivity sign
PLATEPOL
1
0
ROUGHGAIN
FINEGAIN
YA
3
10
13
12
14
9
CLAMPLOW
3
XA
CLAMPHIGH
3
FILTCODE
OUTSLOPE
3
4
2
DCDEF
1
RATIODIS(1)
1
TC1ST
TC2ND_COLD
TC2ND_HOT
OFFDRIFT_COLD
OFFDRIFT_HOT
MLXID
CSTID
7
5
5
6
6
48
17
Trimmed
Trimmed
Trimmed
Trimmed
Trimmed
N/A
32
Trimmed
Rough gain preamplifier
Fine gain from 0.4 to 1.0 in analog mode
Fine gain from -3.999 to +3.999 in PWM mode
Offset compensation VOQ in analog mode
Digital offset in PWM mode
Not used in analog mode
Rough offset compensation in PWM mode
Clamping low level in analog mode
N/A
Trimmed
2
0
2
3
Not used in PWM mode
Clamping high level in analog mode
Clamping high and low level for PWM output
Analog filter in analog mode
Digital filter in PWM mode
Power limitation of the output driver on high frequencies in analog
mode
Output slope control for PWM mode
0
1
0/1(2)
N/A
Trimmed
Trimmed
Trimmed
Trimmed
Trimmed
Programmed
N/A
Not used in analog mode
PWM duty cycle definition
Enable/Disable ratiometry between output signal and supply
Not used in PWM mode
Sensitivity temperature drift correction first order
Sensitivity temperature drift correction second order for cold
temperatures
Sensitivity
temperature drift correction second order for hot
temperatures
Offset temperature drift correction for cold temperatures
Offset temperature drift correction for hot temperatures
MLX ID
Customer ID
Table 92: Customer programmable items
(1): Changing these parameters has an impact on temperature calibration. (2): Default value is 1 only for CAH-021 version.
3901091206
Rev 043
Page 10
Datasheet MLX91206
April 2016
®
MLX91206
®
IMC-Hall Current Sensor (Triaxis Technology)
11.2 Output mode configuration (DSPMODE, OUTMODE)
DSPMODE activates the PWM or the analog mode for the output signal. OUTMODE configures the output
driver.
DSPMODE
0
0
1
1
OUTMODE
0
1
0
1
Output Driver
(1) (2)(3)
Fast analog mode, CL = 1nF..10nF
(1) (2)(4)
Normal analog mode, CL = 5nF..50nF
PWM mode – Open drain
PWM mode – Push pull
Table 13: Output configuration
(1) See section 16, CL = C4.
(2) Factory setting: DSPMODE = 0, OUTMODE = 1.
(3) For applications directly integrated on a PCB, smaller capacitors are allowed at the output pins.
(4) For a standalone application where a cable is connected at the output of the sensor.
11.3 Output impedance mode (DIAGINFAULT)
DIAGINFAULT sets the output impedance mode.
DIAGINFAULT
0
1
Output impedance
Low impedance mode (normal mode)
High impedance mode (diagnostic level)
11.4 Reference edge (REFEDGE) – only in PWM mode
REFEDGE defines the diagnostic level and sets the reference edge.
REFEDGE
0
1
Reference edge
(PWM)
Falling edge
Rising edge
11.5 PWM/switch mode (SWITCH)
In PWM mode, the output can be configured to switch mode.
SWITCH
0
1
3901091206
Rev 043
Operating mode
Disable switch mode
Enable switch mode
Page 11
Datasheet MLX91206
April 2016
MLX91206
®
®
IMC-Hall Current Sensor (Triaxis Technology)
11.6 Platepol (PLATEPOL)
The polarity of the Hall plate versus the output signal is programmable by the PLATEPOL parameter.
PLATEPOL
0
1
Polarity
Positive
Negative
Please note that the factory calibration is done with PLATEPOL=0 . Melexis cannot guarantee the magnetic
specifications if this parameter is changed during customer calibration.
11.7 Sensitivity programming (ROUGHGAIN, FINEGAIN)
The sensitivity is programmable with 3 bits for ROUGHGAIN and 10 bits for FINEGAIN in analog output
application from 60 to 330 V/T (91206-High-Field version) and from 200 to 700 V/T (Low-Field version).
The FINEGAIN resolution depends on the programmed ROUGHGAIN setting. It typically ranges from
0.25V/T (ROUGHGAIN=7) up to 0.01V/T (ROUGHGAIN=0).
Different option codes correspond to different sensitivity ranges:
Ordering
IMC
Typical
Option Code
Version
Sensitivity
580 mV/mT
CAL-001
380 mV/mT
Low field
CAL-002
250 mV/mT
CAL-003
270 mV/mT
CAH-001
170 mV/mT
CAH-002
110 mV/mT
CAH-003
High field
77.5 mV/mT
CAH-004
270mV/mT
CAH-021
3 %DC/mT
CAH-104
Minimum
Sensitivity
460 mV/mT
300 mV/mT
200 mV/mT
210 mV/mT
130 mV/mT
80 mV/mT
60 mV/mT
210 mV/mT
0.5 %DC/mT
Maximum
Sensitivity
700 mV/mT
470 mV/mT
310 mV/mT
330 mV/mT
220 mV/mT
140 mV/mT
110 mV/mT
330mV/mT
5 %DC/mT
In order to have a safety margin regarding mechanical tolerances Melexis recommends designing the
application in such a way that the typical sensitivity can be used with. If the target sensitivity of the module is
out of the defined range (see table above), the hardware and software tools provided by Melexis will not be
able to properly calibrate the sensor.
Different option codes correspond to different electric gains:rderi
Ordering
IMC
Typical
Electrical
Option Code
Version
Rough Gain
Gain
7
240
CAL-001
6
155
Low field
CAL-002
5
100
CAL-003
7
240
CAH-001
7
240
CAH-021
High field
6
155
CAH-002
5
100
CAH-003
Typical
Voq drift [mV]
18
14
9
18
18
14
9
Typical
Noise [mV RMS]
5
3.5
2.5
5
5
3.5
2.5
Since noise and offset drift of the sensor are proportional to the electric gain of the sensor, Melexis
recommends using the version with the smallest gain to optimize the performances.
Note: Power consumption is 2mA less if ROUGHGAIN ≤ 3
3901091206
Rev 043
Page 12
Datasheet MLX91206
April 2016
®
MLX91206
®
IMC-Hall Current Sensor (Triaxis Technology)
11.8 Offset / output quiescent voltage programming (XA, YA)
XA
In analog mode
 12-bit register
 Offset compensation before gain
 @ 0 Gauss w/o offset & @Vdd=5V  Vout = 6.25 * (VOQ Code) / 4096 (clipping can occur!)
 Programming resolution:1.5mV per LSB over the full output range. This corresponds to a calibration
resolution of 0.03%Vdd
In PWM mode
 14-bit register – digital offset VOQ
 Offset compensation before gain
YA
Not used in analog mode
In PWM mode
 9-bit register
 Rough offset compensation (after gain)
11.9 Clamping level programming (CLAMPLOW, CLAMPHIGH)
The clamping levels limit the maximum output levels. CLAMPLOW is not used in PWM application.
The clamping levels are ratiometric (if RATIODIS = 0)
CLAMPLOW
0
1
2
3
4
5
6
7
Minimal output
[%Vdd]
4.8
5.7
6.6
7.5
8.4
9.3
10.2
11.2
Table 14: Clamping low level table analog (typical values)
3901091206
Rev 043
Page 13
Datasheet MLX91206
April 2016
®
MLX91206
®
IMC-Hall Current Sensor (Triaxis Technology)
CLAMPHIGH
0
1
2
3
4
5
6
7
Maximal output
[%Vdd]
90.6
91.4
92.4
93.3
94.3
95.2
96.1
97
Table 15: Clamping high level analog mode (typical values).
The clamping functionality can be disabled by programming CLAMPLOW=CLAMPHIGH=7
CLAMPHIGH
0
1
2
3
4
5
6
7
Minimal output
[%DC]
1
4
5
6
7
8
9
10
Maximal output
[%DC]
99
96
95
94
93
92
91
90
Table 16: Clamping low and high duty-cycle in PWM mode.
The clamping functionality can be disabled by programming CLAMPLOW=CLAMPHIGH=7.
The clamping levels calibrated during final test are:
- 6%Vdd (+/- 0.5%Vdd) for CLAMPING LOW
- 94%Vdd (+/- 0.5%Vdd) for CLAMPING HIGH
11.10 Bandwidth and filter programming (FILTCODE)
FILTCODE allows adjusting the internal bandwidth of the sensor in order to optimize for speed or resolution.
FILTCODE
0
1
2
3
4
5
6
7
Typical Bandwidth [kHz]
(1)
90
9
40
2
9
0.9
4
0.2
Table 17: FILTCODE settings analog mode
(1) Factory settings: FILTCODE = 0.
3901091206
Rev 043
Page 14
Datasheet MLX91206
April 2016
MLX91206
®
®
IMC-Hall Current Sensor (Triaxis Technology)
FILTCODE
2
3
4
5
6
7
8
9
Cut-off frequency [Hz]
557
279
139
70
35
17
9
4
Attenuation [dB]
-8.0
-11.2
-14.4
-18.1
-22.4
-27.1
-32.3
-38.1
Tau [ms]
0.29
0.57
1.14
2.29
4.57
9.14
18.29
36.57
Table 18: FILTCODE settings PWM mode
Note:
-
In analog mode values above 7 are not used
In PWM mode values below 2 and above 9 are not used
11.11 Power limitation / PWM rise and fall time (OUTSLOPE)
OUTSLOPE, in the analog mode case, defines the power limit above which the output driver turns off to
prevent damages to the IC.
The power dissipated in the IC output driver is measured by the IC itself. The power is obtained by multiplying
continuously the voltage across the conducting MOS driver by the output current I out. When the power
reaches the power limit, the output driver is switched off and on such that, on average, the measured power
is maintained equal to the power limit. The power limitation is disabled when OUTSLOPE=3.
Value
0
1
2
3
Power limitation [mW]
50
100
200
(1)
DISABLED
Table 19: Output power limitation in analog mode
(1) Factory settings: OUTSLOPE = 3.
OUTSLOPE, in the PWM mode case, defines the rise and fall times of the PWM transients.
Value
0
1
2
3
Typical Rise Time
11
7
4
2.5
Typical Fall Time
14
8.5
4.5
2.5
Current Limitation [mA]
5
7
13
22
Table 20: PWM rise and fall time, Cout = 10nF, Rpullup = 4.7kOhms
3901091206
Rev 043
Page 15
Datasheet MLX91206
April 2016
®
MLX91206
®
IMC-Hall Current Sensor (Triaxis Technology)
11.12 PWM Mode duty cycle definition (DCDEF)
The PWM duty cycle definition is as follows.
DCDEF
0
1
PWM duty cycle definition
tLow / (tLow + tHigh)
tHigh / (tLow + tHigh)
Table 21: PWM duty cycle definition
11.13 Output ratiometry (RATIODIS)
In case of analog mode (DSPMODE=0) RATIODIS allows enabling and disabling the ratiometry of the output
in reference to the supply voltage by setting respectively 0 and 1 in the EEPROM.
RATIODIS
0
1
Ratiometry
Enabled
Disabled
Please note that the factory calibration is done with RATIODIS=0 excepted for the CAH-021 version where
RATIODIS=1. Melexis cannot guarantee the magnetic specifications if this parameter is changed during
customer calibration.
11.14 Sensitivity and temperature drift programming (TC1ST, TC2ND_COLD,
TC2ND_HOT)
First order sensitivity temperature drift can be trimmed from -2000 to 2000 ppm/degC with TC1ST. The
programming resolution is 40 ppm/degC.
2
Second order sensitivity temperature drift can be trimmed from -6 to 6 ppm/degC with TC2ND. The
2
programming resolution is 0.4/ppm/degC .The second order can also be seen as third order correction since
cold and hot sides are independently adjusted.
11.15 Offset temperature drift programming (OFFDRIFT_COLD, OFFDRIFT_HOT)
Offset temperature drift can be trimmed from -2.25 to +2.25 mV/degC. The programming resolution is 0.075
mV/degC. This first order correction is done independently for temperatures over 25degC and below 25degC.
3901091206
Rev 043
Page 16
Datasheet MLX91206
April 2016
MLX91206
®
®
IMC-Hall Current Sensor (Triaxis Technology)
11.16 Product Identification (MLXID, CSTID)
MLXID
A 48-bit MLX ID is used to guarantee MLX traceability (lotnumber, wafernumber, wafer position & option
code) and is split up in 3x a 16 bit register (MLXID1, MLXID2 & MLXID3)
The programmed option code is stored in MLXID3[2..0]:
(1)
(2)
PSF Option Code
Ordering Option Code
MLXID3[2..0]
7
CAL-001 / CAH-001 / CAH-021
6
CAL-002 / CAH-002
5
CAL-003 / CAH-003
4
CAH-004 / CAH-104
(1) The option code mentioned in all 91206 related documentation (application notes, PSF and User
Interface) refers to the PSF Option Code.
(2) The Ordering Option Code mentioned on the page 1 of this datasheet refers to the Ordering Code,
which defines the Chip version and the sensitivity range of the sensor
CSTID
A 17-bit customer ID is available to create a dedicated traceability system
Self-diagnostic
The MLX91206 provides numerous self-diagnostic features. Those features increase the robustness of the IC
functionality as it prevents the IC to provide erroneous output signal in case of internal or external failure
modes.
Error
Calibration Data CRC Error (at power up
and in normal working mode)
Action
Effect on Outputs
Fault mode
High Impedance mode (1)
Power On delay
High Impedance mode (1)
Remarks
Pull down resistive load => Diag Low
Pull up resistive load => Diag High
1 ms max in high impedance followed
by settling
300mV Hysteresis
Idd < 1mA
500 to 1500mV Hysteresis
Undervoltage Mode (4)
Overvoltage detection Mode 1 (5)
(Threshold : min 7.9 V – max 9.5 V)
Overvoltage detection Mode 2 (6)
(Threshold : min 6.8V – max 7.5V)
IC is reset (7)
IC is switched off
(internal supply)
High Impedance mode (1)
IC is reset (7)
High Impedance mode (1) 100mV Hysteresis
Broken Vss
IC is switched off
High Impedance (2)
Broken Vdd
IC is switched off
High Impedance (3)
High Impedance mode (1)
With some restrictions on pull-up/pulldown resistors on OUT and TEMPOUT,
see Chap. 6 ,Table 3
With some restrictions on pull-up/pulldown resistors on OUT, see Chap. 6 ,
Table 3
Table 22: Self diagnostic
(1)
(2)
(3)
(4)
(5)
(6)
(7)
Refer to Table 3: General electrical parameter, parameter High-impedance modes levels
Refer to Table 3: General electrical parameter, parameter BrokenVss Output Level
Refer to Table 3: General electrical parameter, parameter BrokenVdd Output Level
Refer to Table 3: General electrical parameter, parameter Under-voltage detection
Refer to Table 3: General electrical parameter, parameter Over-voltage detection mode 1
Refer to Table 3: General electrical parameter, parameter Over-voltage detection mode 2
The internal supply is regulated but the digital sequencer (hall element spinning) is stopped
3901091206
Rev 043
Page 17
Datasheet MLX91206
April 2016
®
MLX91206
®
IMC-Hall Current Sensor (Triaxis Technology)
12 Application information
12.1 Low current measurement up to ±2 A
Low currents can be measured with the MLX91206 by
increasing the magnetic field via a coil around the sensor.
The sensitivity (output voltage vs. current in coil) of the
measurement will depend on the size of coil and number
of turns. Additional sensitivity and increased immunity to
external fields can be gained by adding a shield around
the coil. The bobbin provides very high dielectric isolation
making this a suitable solution for high voltage power
supplies with relative low currents. The output should be
scaled to obtain the maximum voltage for the highest
current to be measured in order to obtain the best
accuracy and resolution.
Figure 3: Low current application
12.2 Medium current up to ±30 A
With a single conductor located on the PCB, currents in the
range of up to 30 amps can be measured. The sizing of the
PCB trace needs to take into account the current handling
capability and the total power dissipation. The PCB trace
needs to be thick enough and wide enough to handle the
RMS current continuously.
The differential output voltage for this configuration can be
approximated by the following equation:
Vout = 35 mV/A * I
For a current level of 30 A, the output will be approximately
1050 mV.
Figure 4: Medium current application
12.3 High current measurement up to ±600 A
Another method of measuring high currents on PCB’s is to use
a large thick gauge copper trace capable of carrying the
current on the opposite side of the PCB. The MLX91206
should be located near the centre of the trace, however
because the trace is wide, the output is less sensitive to
location on the PCB. This configuration also has less
sensitivity due to the distance and width of the conductor.
Figure 5: High current application
3901091206
Rev 043
Page 18
Datasheet MLX91206
April 2016
MLX91206
®
®
IMC-Hall Current Sensor (Triaxis Technology)
13 Recommended Application Diagrams
13.1 Resistor and capacitor values
All mentioned component values can have a ±20% tolerance
Part
C1
C2
C3
Description
Supply capacitor, EMI, ESD
Regulator buffer capacitor, decoupling, EMI, ESD
Decoupling, EMI, ESD
Value
10 - 220
10 - 220
5 - 50
Unit
nF
nF
nF
C4
R1
Decoupling, EMI, ESD
Pull up or pull down load resistor
5 – 50 (1)
10 - 30
nF
kΩ
Table 23: Resistor and capacitor value
(1) When OUTMODE=0, which we do not advice in application, capacitor C4 should be 1nF or less.
13.2 Fast analog application, pull-down resistor for diagnostic low
MODULE
ECU
Supply voltage
1
VDD
TEMPOUT
8
MLX91206
C1
2
VSS
3
4
Temperature Output
C3
MUST0
7
VDIG
TESTOUT
6
MUST1
OUT/PWM
5
C2
Analog Output
C4
R1
GND
Figure 6: Fast analog application, Pull-down resistor
3901091206
Rev 043
Page 19
Datasheet MLX91206
April 2016
MLX91206
®
®
IMC-Hall Current Sensor (Triaxis Technology)
13.3 Fast analog application, pull-up resistor for diagnostic high
MODULE
ECU
Supply voltage
1
VDD
TEMPOUT
8
MLX91206
C1
2
VSS
3
4
Temperature Output
C3
MUST0
7
VDIG
TESTOUT
6
MUST1
OUT/PWM
5
C2
R1
Analog Output
C4
GND
Figure 7: Fast analog application, Pull-up resistor
13.4 Robust PWM application, (pull-up load only)
MODULE
ECU
Supply voltage
1
VDD
TEMPOUT
8
MLX91206
C1
2
VSS
3
4
Temperature Output
C3
MUST0
7
VDIG
TESTOUT
6
MUST1
OUT/PWM
5
C2
R1
Analog Output
C4
GND
Figure 8: Robust PWM application with pull-up resistor
3901091206
Rev 043
Page 20
Datasheet MLX91206
April 2016
®
MLX91206
®
IMC-Hall Current Sensor (Triaxis Technology)
14 Standard information regarding manufacturability of Melexis
products with different soldering processes
Our products are classified and qualified regarding soldering technology, solderability and moisture sensitivity
level according to following test methods:
Reflow Soldering SMD’s (Surface Mount Devices)


IPC/JEDEC J-STD-020
Moisture/Reflow Sensitivity Classification for Nonhermetic Solid State Surface Mount Devices
(classification reflow profiles according to table 5-2)
EIA/JEDEC JESD22-A113
Preconditioning of Nonhermetic Surface Mount Devices Prior to Reliability Testing
(reflow profiles according to table 2)
Wave Soldering SMD’s (Surface Mount Devices) and THD’s (Through Hole Devices)


EN60749-20
Resistance of plastic- encapsulated SMD’s to combined effect of moisture and soldering heat
EIA/JEDEC JESD22-B106 and EN60749-15
Resistance to soldering temperature for through-hole mounted devices
Iron Soldering THD’s (Through Hole Devices)

EN60749-15
Resistance to soldering temperature for through-hole mounted devices
Solderability SMD’s (Surface Mount Devices) and THD’s (Through Hole Devices)

EIA/JEDEC JESD22-B102 and EN60749-21
Solderability
For all soldering technologies deviating from above mentioned standard conditions (regarding peak
temperature, temperature gradient, temperature profile etc) additional classification and qualification tests
have to be agreed upon with Melexis.
The application of Wave Soldering for SMD’s is allowed only after consulting Melexis regarding assurance of
adhesive strength between device and board.
Melexis is contributing to global environmental conservation by promoting lead free solutions. For more
information on qualifications of RoHS compliant products (RoHS = European directive on the Restriction Of
the use of certain Hazardous Substances) please visit the quality page on our website:
http://www.melexis.com/quality.aspx
15 ESD Precautions
Electronic semiconductor products are sensitive to Electro Static Discharge (ESD).
Always observe Electro Static Discharge control procedures whenever handling semiconductor products.
3901091206
Rev 043
Page 21
Datasheet MLX91206
April 2016
MLX91206
®
®
IMC-Hall Current Sensor (Triaxis Technology)
16 Package Information
16.1 SOIC8 Package dimensions
1.27 TYP
NOTES:
3.81
3.99**
4.80
4.98*
All dimensions are in millimeters (anlges in degrees).
* Dimension does not include mold flash, protrusions or
gate burrs (shall not exceed 0.15 per side).
** Dimension does not include interleads flash or protrusion
(shall not exceed 0.25 per side).
*** Dimension does not include dambar protrusion.
Allowable dambar protrusion shall be 0.08 mm total in
excess of the dimension at maximum material condition.
Dambar cannot be located on the lower radius of the foot.
5.84
6.20**
1.40
1.55
0.19
0.25
1.55
1.73
0°
8°
0.127
0.250
0.35
0.49***
0.41
0.89
Figure 9: Package dimensions
OUT/PWM
TESTOUT
MUST0
TEMP OUT
16.2 SOIC8 Pinout and Marking
8
Marking :
5
206
206CAL
123456
YYWW
CA
123456
YY
L
Part Number MLX91206 (3 digits)
Die Version (2 digits)
L: Low field (10 mT)
H: High field (25 mT)
Lot number (6 digits)
WW
Week Date code (2 digits)
Year Date code (2 digits)
MUST1
VDIG
VSS
4
VDD
1
Figure 10: Pinout and marking
Note: the option code is not marked on the package. It can be found back in the EEPROM (see chapter
11.12) and on the tape-on-reel label information.
3901091206
Rev 043
Page 22
Datasheet MLX91206
April 2016
MLX91206
®
®
IMC-Hall Current Sensor (Triaxis Technology)
16.3 SOIC8 Hall plate position
0.46 +/- 0.06
1.85
2.15
2.35
2.55
Figure 11: Hall Plate positioning
16.4 IMC Position and sensors active measurement direction
B extern
B extern
Figure 12: IMC position and geometry Low-Field version
B extern
B extern
Figure 13: IMC position and geometry High-Field version
3901091206
Rev 043
Page 23
Datasheet MLX91206
April 2016
®
MLX91206
®
IMC-Hall Current Sensor (Triaxis Technology)
17 Related documents and tools
17.1 Related documents

User Interface UI MLX91206 Description

Product Specific Functions PSF MLX91206 Description

PTC-04 Daughter Board DB-HALL-03 Data Sheet
The latest version of these documents is available on the Melexis Softdist platform. Please contact your local
sales office to request an account (see contact details on page 25).

Non intrusive current sensing with MLX91206 application note

MLX91206 for PDU solutions application note

Calibrating the MLX91206/MLX91207 application note

Shielding for Triaxis current sensors application note
The latest version of these documents is available on the MLX91206 page on the Melexis website:
http://www.melexis.com/Hall-Effect-Sensor-ICs/Special-Purpose-Hall-ICs/MLX91206-755.aspx
17.2 Related software

MLX91206 Firmware

MLX91206 Product Specific Functions (PSF)

MLX91206 User Interface

MLX PTC-04 Product Specific Functions

MLX PTC-04 User Interface
The latest version of these pieces of software is available on the Melexis Softdist platform. Please contact
your local sales office to request an account (see contact details on page 25).
17.3 Related hardware

PTC-04 Programmer for Melexis PTC devices

PTC-04 Daughter Board DB-HALL-03 for MLX91206
3901091206
Rev 043
Page 24
Datasheet MLX91206
April 2016
MLX91206
®
®
IMC-Hall Current Sensor (Triaxis Technology)
18 Disclaimer
Devices sold by Melexis are covered by the warranty and patent indemnification provisions appearing in its
Term of Sale. Melexis makes no warranty, express, statutory, implied, or by description regarding the
information set forth herein or regarding the freedom of the described devices from patent infringement.
Melexis reserves the right to change specifications and prices at any time and without notice. Therefore, prior
to designing this product into a system, it is necessary to check with Melexis for current information. This
product is intended for use in normal commercial applications. Applications requiring extended temperature
range, unusual environmental requirements, or high reliability applications, such as military, medical lifesupport or life-sustaining equipment are specifically not recommended without additional processing by
Melexis for each application.
The information furnished by Melexis is believed to be correct and accurate. However, Melexis shall not be
liable to recipient or any third party for any damages, including but not limited to personal injury, property
damage, loss of profits, loss of use, interrupt of business or indirect, special incidental or consequential
damages, of any kind, in connection with or arising out of the furnishing, performance or use of the technical
data herein. No obligation or liability to recipient or any third party shall arise or flow out of Melexis’ rendering
of technical or other services.
© 2012 Melexis NV. All rights reserved.
For the latest version of this document, go to our website at
www.melexis.com
Or for additional information contact Melexis Direct:
Europe, Africa, Asia:
Phone: +32 1367 0495
E-mail: [email protected]
America:
Phone: +1 248 306 5400
E-mail: [email protected]
ISO/TS 16949 and ISO14001 Certified
3901091206
Rev 043
Page 25
Datasheet MLX91206
April 2016