XP Power F20 Isolated, proportional dc to hv dc converter Datasheet

Proven
Reliabilit y
F SERIES
ISOLATED, PROPORTIONAL DC TO HV DC CONVERTERS
200V to 8kV at 10W
PRODUCT SELECTION TABLE
PRODUCT
PRODUCTDESCRIPTION
DESCRIPTION
The F Series is a broad line of robust, field-proven DC to HV
DC converters which deliver 10 Watts continuous output power.
Outputs range from 200V to 8kV. The input and output are
galvanically isolated so a unit can be used to deliver a positive
or negative high-voltage. The output voltage is proportional to
input voltage with a low 0.7V typical turn-on voltage. The F Series
employs EMCO’s quasi-sinewave oscillator, a fully enclosed
transformer, input and output filtering, and a 5-sided metal
enclosure. As a result, these modules exhibit very low EMI/RFI,
noise and ripple. A dual output option with center-tap pin which,
when grounded provides both positive and negative outputs from
one compact module.
Output Voltage vs. Input Voltage
140 t
120
Output Voltage (%)
100
MODEL
OUTPUT
VOLTAGE*2
OUTPUT
CURRENT*1
F02
0 to 200V
50 mA
F03
0 to 300V
33.3 mA
F04
0 to 400V
25 mA
F05
0 to 500V
20 mA
F06
0 to 600V
16 mA
F08
0 to 800V
12.5 mA
F10
0 to 1kV
10 mA
F12
0 to 1.2kV
8.3 mA
F15
0 to 1.5kV
6.6 mA
F20
0 to 2kV
5 mA
F30
0 to 3kV
3.3 mA
F40
0 to 4kV
2.5 mA
F50
0 to 5kV
2 mA
F60
0 to 6kV
1.66 mA
F70
0 to 7kV
1.5 mA
F80
0 to 8kV
1.25 mA
80
Full-load
60
No-load
40
20
0
0
10
20
30
40
50
60
70
80
90
100
Input Voltage (%)
APPLICATIONS
• Electrophoresis
• Capacitor Charging
• Piezo Devices
• Field Generation
• Grid Bias
• Mass Spectrometry
• Electrostatic Chuck
• Igniter / Spark Module
• Sustaining Ion Pumps
FEATURES
• Proportional Input/Output
• Compact, PCB Mount Package
• Metal Case / Shielded Transformer
• Short Circuit Protection
• Low Ripple, Low EMI / RFI
• Proven Reliability
• Input/Output Isolation
• Low Leakage Current
• Low Input/Output Coupling Capacitance
• No External Components Required
• No Minimum Load Required
• MTBF: >810K hrs per Bellcore TR-332
• RoHS Compliant
OPTIONS
• Dual output (Center Tap) Models Available (CT Suffix)
• Mounting Holes (F02 thru F60 only)(H Suffix)
WWW.XPPOWER.COM
4722AV03
PAGE 1
F SERIES
*2
ELECTRICAL SPECIFICATIONS
MODELS
INPUT
VOLTAGE
OUTPUT
CURRENT
RIPPLE*4
REVERSIBLE
MODEL
OUTPUT
VOLTAGE
DUAL OUTPUT
(CENTER TAP)
MODEL
OUTPUT
VOLTAGE
F02/F02CT
0 to 12V
50mA
<1.0%
F02
0 to 200V
F02CT
0 to +/- 100V
F03/F03CT
0 to 12V
33.3mA
<1.0%
F03
0 to 300V
F03CT
0 to +/- 150V
F04/F04CT
0 to 12V
25mA
<1.0%
F04
0 to 400V
F04CT
0 to +/- 200V
F05/F05CT
0 to 12V
20mA
<0.1%
F05
0 to 500V
F05CT
0 to +/- 250V
F06/F06CT
0 to 12V
16mA
<0.1%
F06
0 to 600V
F06CT
0 to +/- 300V
F08/F08CT
0 to 12V
12.5mA
<0.1%
F08
0 to 800V
F08CT
0 to +/- 400V
F10/F10CT
0 to 12V
10mA
<0.1%
F10
0 to 1kV
F10CT
0 to +/- 500V
F12/F12CT
0 to 12V
8.3mA
<0.1%
F12
0 to 1.2kV
F12CT
0 to +/- 600V
F15/F15CT
0 to 12V
6.6mA
<0.1%
F15
0 to 1.5kV
F15CT
0 to +/- 750V
F20/F20CT
0 to 12V
5mA
<1.0%
F20
0 to 2kV
F20CT
0 to +/- 1kV
F30/F30CT
0 to 15V
3.3mA
<1.0%
F30
0 to 3kV
F30CT
0 to +/- 1.5kV
F40/F40CT
0 to 15V
2.5mA
<1.0%
F40
0 to 4kV
F40CT
0 to +/- 2kV
F50/F50CT
0 to 15V
2mA
<1.0%
F50
0 to 5kV
F50CT
0 to +/- 2.5kV
F60/F60CT
0 to 15V
1.66mA
<1.0%
F60
0 to 6kV
F60CT
0 to +/- 3kV
F70/F70CT
0 to 15V
1.5mA
<2.5%
F70
0 to 7kV
F70CT
0 to +/- 3.5kV
F80/F80CT
0 to 15V
1.25mA
<2.5%
F80
0 to 8kV
F80CT
0 to +/- 4kV
WWW.XPPOWER.COM
4722AV03
PAGE 2
F SERIES
F-SERIES ELECTRICAL SPECIFICATIONS*3
PARAMETER
VALUE
0 TO 12V (F02 TO F20)
INPUT VOLTAGE
0 TO 15V (F30 TO F80)
TURN-ON VOLTAGE
<0.7V
<500MA, NO LOAD
INPUT CURRENT
<1.5A, FULL LOAD
< +/-3.5kV BIAS (F02 TO F60)
ISOLATION
< +/-500V BIAS (F70 TO F80)
INPUT CAPACITANCE
~240uF
RESPONSE TIME
260 ms (typical)
OUTPUT VOLTAGE TOLERANCE
+/-5% (Full Load, 100% output voltage)
FREQUENCY
25 kHz TO 125 kHz
OPERATING TEMPERATURE*5
-10C to +70C (Case)
STORAGE TEMPERATURE
-25C to +90C
BLOCK DIAGRAM
(+) In
1
3
Rectifier &
Multiplier
Oscillator
(+) Output
5
Center tap (for Dual output option)
(-) In
2
4
Transformer
(-) Output
HOT SPOT CASE TEMPERATURE POINT
DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS)
DIMENSIONAL TOLERANCES: .XX = +- 0.03 (0.76), .XXX = +- 0.005 ( 0.127)
WWW.XPPOWER.COM
4722AV03
PAGE 3
F SERIES
MECHANICAL SPECIFICATIONS F02-F60
TOP VIEW
2.80
(71.1)
PCB LAYOUT
COMPONENT SIDE
0.20
(5.1)
0.85 (21.6)
PC PINS
0.031
(0.79)
0.800
(20.32)
0.45
(11.4)
(0.85)
(21.6)
RECOMMENDED
HOLE & PAD O.D. SIZE:
Ø 0.052 (1.32) & Ø 0.082 (2.08)
*5 PLACES
0.900 (22.86)
*
0.400 (10.16)
5
1
0.100 (2.54)
3
0.250 (6.35)
4
1.200
(30.48)
0.35
(8.9)
NOTE: CASE IS INTERNALLY CONNECTED TO (-) INPUT.
DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS)
DIMENSIONAL TOLERANCES: .XX = +- 0.02 (0.51), .XXX = +- 0.005 ( 0.127)
BOTTOM VIEW
PARAMETER
4
2
1.000
(25.40)
5*
2
0
0.500
(12.70)
3
1
1.050 (26.67)
0.800 (20.32)
OPTIONAL
DUAL OUTPUT
(CENTER TAP)
1.750 (44.45)
MTG HOLE (OPTIONAL)
#4/M3 CLEARANCE
2 HOLES.
LOCATION OF
MTG. HOLES (OPTIONAL)
Ø 0.140 (3.56) 2PL
1.200 (30.48)
2.400
(60.96)
0
0.20
(5.1)
TOP VIEW
HIGH
VOLTAGE
1.70
(43.2)
1.300
(33.02)
0.650
(16.51)
0.20
(5.1)
VALUE
PIN #
FUNCTION
WEIGHT
<5 OZ (142 GRAMS)
1
(+) Input
VOLUME
4.0 cu. In. (66.3 cc)
2
(-) Input
DIMENSIONS
2.80L (71.1L) x 1.70W (43.2W) x 0.85H (21.6H)
3
(+) Output
CASE MATERIAL
Black Anodized Aluminum
4
(-) Output
5
Dual Output/Center Tap (optional)
WWW.XPPOWER.COM
4722AV03
PAGE 4
F SERIES
MECHANICAL SPECIFICATIONS F70-F80
TOP VIEW
2.80
(71.1)
HIGH
VOLTAGE
1.70
(43.2)
1.30
(33.0)
Ø .140
(3.56)
MTG HOLES, 2X
#4/M3 CLEARANCE
0.800
(20.32)
5
*
*
0.400 (10.16)
3
1
0.45 (11.4)
OPTIONAL
DUAL OUTPUT
(CENTER TAP)
4
2
RECOMMENDED
HOLE & PAD SIZE:
Ø 0.052 (1.32) & Ø 0.090 (2.29)
3 PLACES
PC PINS
Ø 0.040
(1.02)
TOP VIEW
0.85
(21.6)
1.200
(30.48)
0.95
(24.1)
MIN 0.25
(6.4)
RECOMMENDED
PCB LAYOUT
.25
(6.4)
1.400
(35.56)
Ø 0.250 (6.35) CLEARANCE
FOR 0.215" (5.46mm) O.D.
OUTPUT LEADS
2 PLACES
OUTPUT LEADS:
#22 AWG, 30KV SILICONE
6.00" (152.4mm)
MINIMUM LENGTH.
0.215" (5.46mm) O.D.
2 PLACES.
NOTE: CASE IS INTERNALLY CONNECTED TO (-) INPUT.
DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS)
DIMENSIONAL TOLERANCES: .XX = +- 0.02 (0.51), .XXX = +- 0.005 ( 0.127)
PARAMETER
VALUE
PIN #
FUNCTION
WEIGHT
<5 OZ (142 GRAMS)
1
(+) Input
VOLUME
4.5 cu. In. (74.1cc)
2
(-) Input
DIMENSIONS
2.80L (71.12L) x 1.70W (43.18W) x 0.95H (24.13H)
3
(+) Output
CASE MATERIAL
Black Anodized Aluminum
4
(-) Output
5
Dual Output/Center Tap (optional)
WWW.XPPOWER.COM
4722AV03
PAGE 5
F SERIES
OPTION CODE TABLE
OPTION
POLARITY
OPTIONS
ORDER CODE
MODELS
Positive / Negative reversible
Blank
ALL
Dual Output (center tap) option
CT
ALL
ROHS
R
ALL
Mounting Holes
H
UP TO 6KV
HOW TO ORDER
PART NUMBER SELECTOR:
Model Number:
F30CTH
Model
Output Voltage (See table)
Mounting Holes (optional)
Center Tap (for dual output option)
EXAMPLE: F30CTH (F-Model, 30-Output Voltage, CT-Center Tap, H-Holes)
* Notes:
1. At maximum rated output voltage.
2. Output voltage is load dependent. Under light or no load conditions, reduce input voltage so maximum rated output voltage is not exceeded.
3. Specifications after 1 hour warm up, full load, at 25C unless otherwise indicated.
4. Ripple specification for dual output units applies to the voltage between the positive and negative output terminals.
5. Proper thermal management techniques are required to maintain safe case temperature at maximum power output
XP EMCO reserves the right to make changes on products and literature, including specifications, without notice. XP EMCO standard product models are not recommended for “copy-exact” applications or any other application restricting product
changes. “Copy-exact” options are available. Please contact an XP EMCO sales representative for more details.
WWW.XPPOWER.COM
4722AV03
PAGE 6