Bourns H-550 Turns-counting dial Datasheet

Model H-550 is currently available,
although not recommended for new
designs. Model H-46 is preferred.
PL
IA
NT
Features
S
CO
M
■
*R
oH
■
■
■
■
■
Large package size - 46 mm diameter
“Metalized” plastic dial body
Strong locking brake
Economical
Ideal for use with 10-turn potentiometers
RoHS compliant*
H-550 Turns-Counting Dial
Mechanical and Physical Characteristics
Number of Turns ..................................................................................................................................................................................0 to 11
Dial Divisions ...............................................................................................................................................................................100 per turn
Readability – Over 10 Turns .........................................................................................................................................Within 1/100 of a turn
Torque With Brake Engaged.....................................................................................................................8.47 N-cm (12.0 oz.-in.) maximum
Markings...........................................................................................................................................................................Black on clear gray
Locking Brake............................................................................................................................................................................................Yes
Weight...............................................................................................................................................................................13 grams (0.46 oz.)
Set Screw .................................................................................................................................................................UNC 4/40, one included
Set Screw Tightening Torque ......................................................................................................................12.00 N-cm (17 oz-in.) minimum
17.65 N-cm (25 oz-in.) maximum
Hex Key Size ................................................................................................................................................................................0.05 in. hex
Shaft and Bushing Requirements
Shaft Diameter Requirements .......................................................................................................................0.635 mm (0.0250 in.) diameter
Shaft Extension Beyond Panel .........................................................................................................................17.5 mm (0.689 in.) minimum
22.5 mm (0.886 in.) maximum
Bushing Extension Beyond Panel .....................................................................................................................7.0 mm (0.276 in.) maximum
E
T
E
L
O
S
B
O
H-550 MOUNTING INSTRUCTIONS
Using the existing Antirotation Lug
1. Drill 3.2 mm (0.125) diameter antirotation pin hole on vertical
centerline 14.3 mm (0.562) below center of potentiometer
mounting hole.
2. Mount potentiometer shaft counterclockwise to obtain minimum
resistance or voltage ratio. This is not necessarily identical with the
mechanical stop.
4. Loosen set screws in knob of dial. Set dial to “0.0” reading.
5. While holding outer ring of dial, position unit lightly against panel.
Tighten knob set screws to potentiometer shaft.
Dimensional Drawing
DIMENSIONS:
MM
(IN.)
24.6
(.96)
15.9
(.625)
10.31
DIA.
(.405)
46.0
(1.811)
14.30
(.562)
3.17
(.124) DIA.
PANEL LAYOUT
How to Order
Part
Number
REV. 10/08
*RoHS Directive 2002/95/EC Jan 27 2003 including Annex.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
Accepts Shaft
Diameter
Finish
H-550-6A (10 per box)
6.35 mm (.250 in.)
Grey Metalized Plastic
H-550-6A-1 (1 per box)
6.35 mm (.250 in.)
Grey Metalized Plastic