Parameter
Input Voltage Range
Input Filter
Input Reflected Ripple Current
Conditions
Min.
24 VDC Input
9.0
48 VDC Input 18.0
␲ (Pi) Filter
Typ.
24.0
48.0
Max.
36.0
75.0
20.0
Units
VDC
mA P - P
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation, Single Output
Load Regulation, Dual Output
Ripple & Noise (20 MHz) (Note 1)
Output Power Protection
Transient Recovery Time (Note 2)
Transient Response Deviation
Temperature Coefficient
Output Short Circuit Protection
Conditions
Min.
Dual Output , Balanced Loads
Vin = Min to Max
Iout = 0% to 100%
Iout = 0% to 100%
Typ.
±1.0
±0.5
Max.
±0.5
±0.5
±1.0
75
120
250
25% Load Step Change
±3.0
±0.02
Continuous (Autorecovery)
Units
%
%
%
%
%
mV P - P
% IOUT
µSec
%
%/°C
General
Parameter
Isolation Voltage (Input/Output)
Isolation Voltage (Case/Input(output)
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
3 Seconds
3 Seconds
500 VDC
100 kHz, 1V
Min.
1,600
1,600
1,000
Typ.
Max.
Units
VDC
M⍀
pF
kHz
1,200
330
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions (Note 3)
ESD
RS
EFT (Note 4)
Surge (Note 4)
CS (Note 4)
PFMF
Standard
Level
Class A
Class A
Criteria B
Criteria A
Criteria B
Criteria B
Criteria A
Criteria A
EN55022
EN55022
EN6100-4-2
EN6100-4-3
EN6100-4-4
EN6100-4-5
EN6100-4-6
EN6100-4-8
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
RFI
Physical
Case Size
Case Material
Weight
Conditions
Ambient
Case
Min.
-40
Typ.
+25
-40
Free Air Convection
RH, Non-condensing
Six-Side Shielded Metal Case
Max.
+66
+105
+125
Units
°C
°C
°C
95
%
2.0 x 1.0 x 0.40 Inches (50.8 x 25.4 x 10.2 mm)
Metal with Non-Conductive Base (UL94-V0)
1.06 Oz (30g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
560
Typ.
Max.
Units
kHours
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
Min.
-0.7
-0.7
Typ.
Max.
50.0
100.0
260.0
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Output
Over
Max
Voltage Efficiency Fuse Rating Capacitive
Voltage Current
Current Protection (%, Typ) Slow-Blow
Load
(mA)
(VDC)
(µF Max)
Full-Load No-Load (VDC) (mA, Max) (mA, Min)
Voltage (VDC)
Current (mA)
Nominal
Range
B2001RU
24
9.0 - 36.0
879
50
3.3
5,500.0
0.0
3.9
89
2,000
10,000
B2002RU
24
9.0 - 36.0
957
50
5.0
4,000.0
0.0
6.2
90
2,000
6,800
B2003RU
24
9.0 - 36.0
980
22
12.0
1,670.0
0.0
15.0
88
2,000
1,000
B2004RU
24
9.0 - 36.0
968
22
15.0
1,330.0
0.0
18.0
89
2,000
680
B2005RU
24
9.0 - 36.0
968
65
±5.0
±2000.0
0.0
±6.2
89
2,000
±2,200
B2006RU
24
9.0 - 36.0
980
25
±12.0
±835.0
0.0
±15.0
88
2,000
±470
B2007RU
24
9.0 - 36.0
980
25
±15.0
±665.0
0.0
±18.0
88
2,000
±330
B2011RU
48
18.0 - 75.0
440
30
3.3
5,500.0
0.0
3.9
89
1,500
10,000
B2012RU
48
18.0 - 75.0
413
30
5.0
4,000.0
0.0
6.2
91
1,500
6,800
B2013RU
48
18.0 - 75.0
484
15
12.0
1,670.0
0.0
15.0
89
1,500
1,000
B2014RU
48
18.0 - 75.0
484
15
15.0
1,330.0
0.0
18.0
89
1,500
680
B2015RU
48
18.0 - 75.0
484
40
±5.0
±2000.0
0.0
±6.2
89
1,500
±2,200
B2016RU
48
18.0 - 75.0
490
15
±12.0
±835.0
0.0
±15.0
88
1,500
±470
B2017RU
48
18.0 - 75.0
490
15
±15.0
±665.0
0.0
±18.0
88
1,500
±330
Notes:
1. Transient recovery is measured to within a 1% error band for a load step change of
75% to 50% to 25%.
2. Operation at no-load will not damage these units. However, they may not meet all
specifications.
3. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC output.
To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs
and float the output common.
4. It is recommended that a fuse be used on the input of a power supply for protection.
See the table above for the correct rating.
Recommended Input/Output Components
Remote ON/OFF
Parameter
Min
Max
Units
Supply On
3.0
12 or Open
VDC
Supply Off
0.0
1.2
VDC
Standby Input Current
5 mA Typical
Control Common
Referenced to Neg. Input (pin 2)
To help meet EN55022 conducted emissions requirements, a simple Pi filter
should be added externally to the input of the converter. Recommended
components (C1, C2 & L1) are shown in the diagram above.These components should be mounted as close to the module as possible.
To meet the requiremets of EN61000-4-4, EN61000-4-5 and EN61000-4-6,
an external capacitor is required. It is recommended that the value shown in
the figure above (C3) be used.
A positive logic Remote On/Off input (Pin 6) can be used
to control the converter. An open collector (or open
drain) switch (Q1) is placed between the control input
(Pin 6) and the -V Input (Pin 2).
When measuring output ripple, it is recommended that an external 1.0 µF
ceramic capacitor be placed from the +Vout pin to the -Vout pin for single
output units and from each output to common for dual output units. For
noise sensitive applications, the use of 3.3 µF capacitors (as shown in the
diagram above) will reduce the output ripple.
If not being used, the control input should be left open.
Page 2
Web: www.micropowerdirect.com • Email: [email protected] • Tel: (781) 344 - 8226 • Fax: (781) 344 - 8481
B2000RU
MicroPower
Direct
Series
Output Trim (Single Output Models)
A simple external circuit may be used to adjust Vout on
single output models. To adjust the output DOWN, connect a 5%, 3W resistor between the plus output pin and
the Vout trim pin. To adjust the output UP, connect a 5%,
3W resistor between the minus output pin and the Vout
trim pin. Resistor values are given in the chart below.
For UP/Down trimming capability, connect a 10 kW potentiometer between the plus and minus outputs with the
wiper arm connected to the Vout trim pin.
Care should be taken that the maximum output power of
the unit does not exceed the maximum rating.
B2001RU, B2011RU
Trim Down
Vout =
RTRIM Down =
2
3
4
5
6
7
8
9
10
%
3.234
3.201
3.168
3.135
3.102
3.069
3.036
3.003
2.970
VDC
79.806
59.153
44.930
34.539
26.616
20.374
15.330
k⍀
4
5
6
7
8
9
10
%
315.932 172.257 112.528
Trim UP
Vout =
RTRIM Up =
1
3.267
1
2
3
3.333
3.366
3.399
544.612 184.034 103.305
3.432
3.465
3.498
3.531
3.564
3.597
3.630
VDC
67.715
47.676
34.824
25.880
19.297
14.249
10.255
k⍀
B2002RU, B2012RU
Trim Down
Vout =
RTRIM Down =
2
3
4
5
6
7
8
9
10
%
4.900
4.850
4.800
4.750
4.700
4.650
4.600
4.550
4.500
VDC
64.301
43.281
30.643
22.207
16.177
11.651
8.129
5.310
k⍀
230.566 106.182
Trim UP
Vout =
RTRIM Up =
1
4.950
1
2
3
4
5
6
7
8
9
10
%
5.050
5.100
5.150
5.200
5.250
5.300
5.350
5.400
5.450
5.500
VDC
70.631
49.142
36.274
27.707
21.592
17.010
13.447
10.598
k⍀
244.547 113.776
B2003RU, B2013RU
Trim Down
1
2
3
4
5
6
7
8
9
10
%
Vout =
11.880
11.760
11.640
11.520
11.400
11.280
11.160
11.040
10.920
10.800
VDC
RTRIM Down =
327.351 142,100
83.928
55.470
38.591
27.418
19.477
13.542
8.939
5.264
k⍀
Trim UP
1
2
3
4
5
6
7
8
9
10
%
Vout =
12.120
12.240
12.360
12.480
12.600
12.720
12.840
12.960
13.080
13.200
VDC
RTRIM Up =
371.425 183.645 117.623
83.929
63.489
49.767
39.919
32.508
26.728
22.094
k⍀
B2004RU, B2014RU
Trim Down
1
2
3
4
5
6
7
8
9
10
%
Vout =
14.850
14.700
14.550
14.400
14.250
14.100
13.950
13.800
13.650
13.500
VDC
RTRIM Down =
433.811 174.916 100.946
65,907
45.468
32.077
22.625
15.596
10.165
5.842
k⍀
Trim UP
1
2
3
4
5
6
7
8
9
10
%
Vout =
15.150
15.300
15.450
15.600
15.750
15.900
16.050
16.200
16.350
16.500
VDC
RTRIM Up =
347.293 178.523 115.235
82.084
61.683
47.863
37.882
30.336
24.430
19.682
k⍀
Web: www.micropowerdirect.com • Email: [email protected] • Tel: (781) 344 - 8226 • Fax: (781) 344 - 8481
Page 3
Derating Curve
www.micropowerdirect.com
Pin Connections
Pin
Single
Dual
1
+Vin
+Vin
2
-Vin
-Vin
3
+Vout
+Vout
4
Trim
Common
5
-Vout
-Vout
6
Remote On/Off
Remote On/Off
Mechanical Dimensions
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages