90W AC-DC High Reliability Industrial Adaptor ■ Features Universal AC input / Full range 3 pole AC inlet IEC320-C14 Built-in active PFC function No load power consumption<0.15W Energy efficiency Level VI Comply with EISA 2007/DoE,NRCan, GST90A series ■ Applications Consumer electronic devices Telecommunication devices Office facilities Industrial equipments AU/NZ MEPS,EU ErP and CoC Version 5 ClassⅠpower (with earth pin) Protections: Short circuit / Overload / Over voltage / Over temperature Fully enclosed plastic case Fanless design with -30~+70℃ working temperature LED indicator for power on 3 years warranty ■ Description GST90A is a highly reliable, 90W desktop style single-output green adaptor series. This product is a classⅠ power unit (with FG), equipped with a standard IEC320-C14 AC inlet and adopting the input range from 90VAC to 264VAC. The entire series supplies different models with output voltages ranging between 12VDC and 48VDC that can satisfy the demands for various types of consumer electronic devices. With the efficiency up to 91% and the extremely low no-load power consumption below 0.15W,GST90A is compliant with USA EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, EU ErP,and Code of Conduct (CoC) Version 5. The supreme feature allows the adaptor to save the energy when it is either under the operating mode or the standby mode. The entire series utilizes the 94V-0 flame retardant plastic case.GST90A is certified for the international safety regulations. ■ Model Encoding GST 90 A 12 - P1M DC plug type { P1M: Plug for standard model,2.5ψ x5.5ψ x11mm,c+,tuning fork type Optional plug type available by customer requested Output voltage IEC320-C14 AC inlet Output wattage Series name File Name:GST90A-SPEC 2015-06-12 90W AC-DC High Reliability Industrial Adaptor GST90A series SPECIFICATION ORDER NO. SAFETY MODEL NO. DC VOLTAGE OUTPUT NOTE GST90A48-P1M GST90A12 GST90A15 GST90A19 GST90A24 GST90A48 15V 19V 24V 48V 1.87A 6A 4.74A 3.75A CURRENT RANGE 0 ~ 6.67A 0 ~ 6A 0 ~ 4.74A 0 ~ 3.75A 0 ~ 1.87A RATED POWER (max.) 80W 90W 90W 90W 90W 240mVp-p RIPPLE & NOISE (max.) Note.3 120mVp-p 150mVp-p 180mVp-p 200mVp-p VOLTAGE TOLERANCE Note.4 ±5.0% ±5.0% ±4.0% ±3.0% ±2.5% Note.5 ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±5.0% ±5.0% ±4.0% ±3.0% ±2.5% 90% 91% SETUP, RISE TIME Note.6 1000ms, 50ms / 230VAC HOLD UP TIME (Typ.) VOLTAGE RANGE Note.7 90 ~ 264VAC 20ms / 230VAC 1000ms, 50ms / 115VAC at full load 20ms / 115VAC at full load 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.91 / 230VAC EFFICIENCY (Typ.) 89% AC CURRENT (Typ.) INRUSH CURRENT (max.) 1.3A / 115VAC PF>0.95 / 115VAC at full load 89.5% 90% 0.6A / 230VAC 70A / 230VAC LEAKAGE CURRENT(max.) 1mA / 240VAC OVERLOAD 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 105 ~ 135% rated output voltage Protection type : Shut down o/p voltage, re-power on to recover OVER VOLTAGE OVER TEMPERATURE Shut down o/p voltage, re-power on to recover WORKING TEMP. WORKING HUMIDITY -30 ~ +70℃ (Refer to "Derating Curve") 20% ~ 90% RH non-condensing SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC (Note. 8) EMC EMISSION CONNECTOR GST90A24-P1M 6.67A ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION OTHERS GST90A19-P1M Note.2 12V LOAD REGULATION PROTECTION GST90A15-P1M RATED CURRENT LINE REGULATION INPUT GST90A12-P1M -40 ~ +85℃, 10 ~ 95% RH ±0.03% / ℃ (0~40℃) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1,CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1 approved I/P-O/P: 3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254, GB17625.1 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A MTBF DIMENSION PACKING PLUG 348.7K hrs min. MIL-HDBK-217F(25℃) 145*60*32mm (L*W*H) 0.45Kg; 30pcs/14.05Kg/1CUFT See page 3 ; Other type available by customer requested CABLE See page 3 ; Other type available by customer requested 1. All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient. 2. DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4. Tolerance: includes set up tolerance, line regulation, load regulation. 5. Line regulation is measured from low line to high line at rated load. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. Derating may be needed under low input voltages. Pleas check the derating curve for more details. 8. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) File Name:GST90A-SPEC 2015-06-12 GST90A 90W AC-DC High Reliability Industrial Adaptor Derating Curve series Static Characteristics 100 100 90 80 80 60 70 LOAD (%) LOAD (%) 50 40 20 -30 0 10 20 30 40 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE (℃) 50 40 90 95 100 110 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz Mechanical Specification Case No. GS90A Unit:mm Ul1185 14AWG 1000±50mm for 12 ~ 15V UL1185 16AWG 1200±50mm for 19 ~ 48V 145 32 60 60 70±10mm C"+" 11±0.5mm POWER LED ID 2.5 x OD 5.5 Outside Inside -V not connected to AC FG Plug Assignment Standard plug: P1M P1M P/N OUTPUT CENTER + Installation Manual Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html File Name:GST90A-SPEC 2015-06-12