VMI M100FF3 High voltage diodes - axial lead 20ma - 40ma â ¢ 30ns - 50ns â ¢ hermetic Datasheet

High Voltage Diodes - Axial Lead
20mA - 40mA • 30ns - 50ns • Hermetic
ELECTRICAL CHARACTERISTICS AND MAXIMUM RATINGS
Part
Number
Working
Reverse
Voltage
Average
Rectified
Current
Reverse
Current
@ Vrwm
Forward
Voltage
(Vrwm)
(Io)
(Ir)
(Vf)
55°C(1) 100°C(2) 25°C 100°C
1 Cycle Repetitive Reverse
Surge
Surge Recovery
Current
Current
Time
tp=8.3ms
(3)
(Ifsm)
(Ifrm)
(Trr)
25°C
25°C
25°C
25°C
Junction
C ap.
@50VDC
@ 1kHZ
(Cj)
Thermal
Impedance
θJ-L
L=.000 L=.125 L=.250
25°C
Volts
mA
mA
µA
µA
Volts
mA
Amps
Amps
ns
°C/W
°C/W
°C/W
pF
M50FF3
M100FF3
5000
10000
40
20
20
10
0.1
0.1
10
10
12.5
25.0
40
20
2.0
1.0
0.4
0.2
30
30
18
18
30
30
50
50
1.0
0.5
M50FF5
M100FF5
5000
10000
40
20
20
10
0.1
0.1
10
10
12.5
25.0
40
20
2.0
1.0
0.4
0.2
50
50
18
18
30
30
50
50
1.0
0.5
(1)TL=55°C L=0.375" (2)TL=100°C L=0.375" (3)If=12.5mA, Ir=25mA, Irr=6.3mA *Op.Temp.= -65°C to +175°C Stg.Temp.= -65°C to +200°C
Part
A
M50FF3
.225(5.72) MAX.
M100FF3
.300(7.62) MAX.
M50FF5
.225(5.72) MAX.
M100FF5
.300(7.62) MAX.
Dimensions: In. (mm)
All temperatures are ambient unless otherwise noted.
Voltage Multipliers Inc.
8711 W. Roosevelt Ave.
Visalia, CA 93291 USA
VOLTAGE MULTIPLIERS INC.
20
Data subject to change without notice.
Tel:
559.651.1402
Fax:
559.651.0740
www.voltagemultipliers.com
www.highvoltagepowersupplies.com
M50FF3/5 M100FF3/5
TYPICAL FORWARD VOLTAGE
VS. FORWARD CURRENT AT 25°C
POWER DERATING
4.5
60
L=0.200"
L=0.100"
50
L=0.000"
3.5
Forward Voltage (V)
Maximum Power Dissipation (W)
4.0
3.0
2.5
2.0
1.5
L=0.300"
L=0.400"
L=0.500"
1.0
0.5
40
M100FF5
30
M50FF5
3
20
10
0.0
0
0
25
50
75
100
125
Lead Temperature (°C)
150
175
0
REVERSE CURRENT
VS. TEMPERATURE AT Vrwm
1000
0.1
0.2
0.3
Forward Current (A)
0.4
0.5
TYPICAL FORWARD VOLTAGE
VS. FORWARD CURRENT AT 25°C
60
100
Forward Voltage (V)
Reverse Current (µA)
50
10
40
M100FF3
30
M50FF3
20
1
10
0.1
0
25
50
75
100
Temperature (°C)
125
0
150
TYPICAL REVERSE RECOVERY TIME
VS. TEMPERATURE
140
0.4
0.5
1.2
Junction Capacitance (pF)
Reverse Recovery Time (ns)
0.2
0.3
Forward Current (A)
TYPICAL JUNCTION CAPACITANCE
VS. REVERSE VOLTAGE AT 25°C
1.4
120
0.1
100
80
60
40
20
1.0
M50FF3/5
M100FF3/5
0.8
0.6
0.4
0.2
0
0.0
25
50
75
100
Temperature (°C)
125
150
21