MPD D100EI Low cost, 1w sip high isolation dc/dc converter Datasheet

D100EI Series
Low Cost, 1W SIP
High Isolation
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
Parameter
Conditions
Min.
Typ.
Max.
5 VDC Input
4.5
5.0
5.5
12 VDC Input
10.8
12.0
13.2
24 VDC Input
21.6
24.0
26.4
• 1W Output Power
• Miniature SIP Case
• 3,000 VDC Isolation
• UL Approved (File E245422)
• Single & Dual Outputs
Input Voltage Range
Input Filter
VDC
Internal Capacitor
Reverse Polarity Input Current
0.3
A
Units
Output
• >3.5 MHour MTBF
Parameter
• 24 Standard Models
Output Voltage Accuracy
• LOWEST COST!!
Output Voltage Balance
Line Regulation
Load Regulation (Note 1)
Conditions
Min.
Typ.
Max.
±1.0
±3.0
%
Dual Output , Balanced Loads
±0.1
±1.0
%
For Vin Change of 1%
±1.2
%
See Model Selection Guide
Ripple & Noise (20 MHz) (Note 2)
50
Output Power Protection
75
mV P - P
120
Temperature Coefficient
%
±0.02
Output Short Circuit
RoHS Compliant
Units
±0.03
%/ºC
Max.
Units
Momentary (1.0 Sec.)
General
Parameter
Conditions
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Min.
60 Seconds
3,000
500 VDC
1,000
100 kHz, 1V
Switching Frequency
Typ.
VDC
MΩ
60
pF
150
kHz
Environmental
Parameter
Conditions
Operating Temperature Range
Ambient
Storage Temperature Range
Typ.
Max.
-40
+25
+85
ºC
+125
ºC
95
%
-55
Cooling
Humidity
Min.
Units
Free Air Convection
RH, Non-condensing
Physical
MicroPower Direct
Case Size
292 Page Street
Suite D
Stoughton, MA 02072
USA
Case Material
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
MTBF
0.77 x 0.24 x 0.40 Inches (19.6 x 6.0 x 10.2 mm)
Non-Conductive Black Plastic (UL94-V0)
Weight
0.07 Oz (2.1g)
Reliability Specifications
Parameter
Conditions
Min.
MIL HDBK 217F, 25ºC, Gnd Benign
Typ.
Max.
3.5
Units
MHours
Safety Standards
UL 1950, EN 60950, IEC 60950
Safety Approvals
UL, cUL; File No. E245422
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
Conditions
Min.
Typ.
Max.
5 VDC Input
-0.7
9.0
12 VDC Input
-0.7
18.0
24 VDC Input
-0.7
30.0
Units
VDC
1.5 mm From Case For 10 Sec
300
ºC
All Models
450
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model
Number
D101EI
D102EI
D103EI
D104EI
D105EI
D106EI
D107EI
D108EI
D111EI
D112EI
D113EI
D114EI
D115EI
D116EI
D117EI
D118EI
D121EI
D122EI
D123EI
D124EI
D125EI
D126EI
D127EI
D128EI
Input
Output
Load
Voltage (VDC)
Current (mA)
Regulation
Voltage Current
Current
Nominal
Range
Full-Load No-Load (VDC) (mA, Max) (mA, Min) (%, Max)
5
4.5 - 5.5
286
30
5.0
200.0
20.0
15
5
4.5 - 5.5
267
30
9.0
111.0
12.0
15
5
4.5 - 5.5
256
30
12.0
83.0
9.0
15
5
4.5 - 5.5
250
30
15.0
67.0
7.0
15
5
4.5 - 5.5
278
30
±5.0
±100.0
±10.0
15
5
4.5 - 5.5
267
30
±9.0
±56.0
±6.0
15
5
4.5 - 5.5
256
30
±12.0
±42.0
±5.0
15
5
4.5 - 5.5
253
30
±15.0
±33.0
±4.0
15
12
10.8 - 13.2
115
15
5.0
200.0
20.0
15
12
10.8 - 13.2
110
15
9.0
111.0
12.0
15
12
10.8 - 13.2
105
15
12.0
83.0
9.0
15
12
10.8 - 13.2
103
15
15.0
67.0
7.0
15
12
10.8 - 13.2
113
15
±5.0
±100.0
±10.0
15
12
10.8 - 13.2
110
15
±9.0
±56.0
±6.0
15
12
10.8 - 13.2
105
15
±12.0
±42.0
±5.0
15
12
10.8 - 13.2
104
15
±15.0
±33.0
±4.0
15
24
21.6 - 26.4
57
8
5.0
200.0
20.0
15
24
21.6 - 26.4
54
8
9.0
111.0
12.0
15
24
21.6 - 26.4
52
8
12.0
83.0
9.0
15
24
21.6 - 26.4
51
8
15.0
67.0
7.0
15
24
21.6 - 26.4
56
8
±5.0
±100.0
±10.0
15
24
21.6 - 26.4
55
8
±9.0
±56.0
±6.0
15
24
21.6 - 26.4
52
8
±12.0
±42.0
±5.0
15
24
21.6 - 26.4
51
8
±15.0
±33.0
±4.0
15
Efficiency
(%, Typ)
70
75
78
80
72
75
78
79
72
76
79
81
74
76
79
80
73
77
80
82
74
76
80
81
Fuse Rating
Slow-Blow
(mA)
500
500
500
500
500
500
500
500
200
200
200
200
200
200
200
200
100
100
100
100
100
100
100
100
Derating Curve
Other input/output combinations are available
(i.e. 3.3 VDC). Contact the factory for details at:
[email protected]
Notes:
1. Output load regulation is specified for a load change of 10% to 100%.
2. These units should not be operated with a load under 10% of full load.
Operation at no-load may cause damage to the unit.
3. These converters will operate without external components. However,
when measuring output ripple, it is recommended that an external ceramic
capacitor be placed
Output Capacitor
Input
from the +Vout pin to
Vin
Vout
Capacitor
Single
Dual
the -Vout pin for single
output units and from
5 VDC
4.7 μF
5 VDC 10.0 μF 4.7 μF
each output to common 12 VDC
2.2 μF
9 VDC
4.7 μF
2.2 μF
for dual output units.
24 VDC
1.0 μF
12 VDC 2.2 μF
1.0 μF
An input capacitor will
15 VDC 1.0 μF 0.47 μF
enhance stability over
Mechanical Dimensions
temperature and input line variations. Recommended capacitor values are
given in the table above. For applications requiring very low output noise
levels, a simple LC filter should be effective.
4. Dual output units may be connected to provide a 10V, 18V, 24V or
30 VDC output. To do this, connect the load across the positive (+Vout) and
negative (-Vout) outputs and float the output common
5. It is recommended that a fuse be used on the input of a power supply for
protection. See the Model Selection table above for the correct rating.
Pin Connections
Pin
Single
Dual
Pin
Single
Dual
1
2
5
+Vin
-Vin
-Vout
+Vin
-Vin
-Vout
6
7
No Pin
+Vout
Common
+Vout
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” or indentation on the side of the unit
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]