MPD MD612D-12RWI 2:1 input, sip, high isolation, 6w dc/dc converter Datasheet

MD600xRWI Series
2:1 Input, SIP,
High Isolation, 6W
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
Parameter
Conditions
• 6W Output Power
• Miniature SIP Case
5 VDC Input
12 VDC Input
24 VDC Input
48 VDC Input
Input Voltage Range
• 2:1 Input Voltage Range
• 3,000 VDC Isolation
• 36 Standard Models
• Short Circuit Protected
• -40°C to +65°C Operation
• Single & Dual Outputs
• Industry Standard Pin-Out
Input Reflected Ripple Current
Start Up Time
Input Filter
Min.
4.5
9.0
18.0
36.0
See Note 1
Capacitor Filter
Typ.
5.0
12.0
24.0
48.0
30
30
Max.
9.0
18.0
36.0
75.0
Typ.
±1.0
Max.
Units
VDC
mA P - P
mS
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Cross Regulation
Ripple & Noise (20 MHz)
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
Conditions
Min.
VIN = Min to Max
IOUT = 0% to 100%
See Note 2
See Note 3
±0.2
±1.0
±5.0
75
0.5
See Note 4
±3.0
±0.02
Continuous (Autorecovery)
Units
%
%
%
%
mV P - P
mSec
%
%/°C
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
Conditions
60 Seconds
Min.
3,000
1.0
Typ.
Max.
50
100
Standard
Level
Class A
Class A
Criteria A; ±8 kV Air
Criteria A; ±6 kV Contact
Criteria A; 10V/m
Criteria A; ±2 kV
Criteria A; ±1 kV
Criteria A; 10 Vrms
Criteria A; 1A/m
EN 55022
EN 55022
See Note 4 Pg 3
ESD
EN 61000-4-2
RS
EFT
Surge
CS
PFMF
See Note 6 Pg 3
See Note 6 Pg 3
Units
VDC
G
pF
kHz
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Ambient
Case
Min.
-40
Typ.
+25
-55
Free Air Convection
RH, Non-condensing
Max.
+65
+105
+125
Units
°C
°C
°C
95
%
See Mechanical Drawing (Page 4)
Non-Conductive Black Plastic (UL94-V0)
0.166 Oz (4.8g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
770
Typ.
Max.
Units
kHours
Min.
Typ.
Max.
15.0
25.0
50.0
100.0
260
Units
Absolute Maximum Ratings
Parameter
Conditions
Input Voltage Surge (1 Sec)
Lead Temperature
5 VDC Input
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case for 10 Sec
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Voltage (VDC)
Output
Current (mA)
Voltage
Current
Current
Full-Load No-Load
(VDC)
(mA, Max)
(mA, Min)
Fuse
Efficiency Capacitive
Rating
Load
(%, Typ)
Slow-Blow
(µF, Max)
(mA)
Nominal
Range
MD605S-03RWI
5
4.5 - 9.0
1,144
105
3.3
1,300
0.0
75
6,600
3,000
MD605S-05RWI
5
4.5 - 9.0
1,519
105
5.0
1,200
0.0
79
3,300
3,000
MD605S-09RWi
5
4.5 - 9.0
1,445
105
9.0
666
0.0
83
2,000
3,000
MD605S-12RWI
5
4.5 - 9.0
1,428
105
12.0
500
0.0
84
1,600
3,000
MD605S-15RWI
5
4.5 - 9.0
1,428
105
15.0
400
0.0
84
1,400
3,000
MD605S-24RWI
5
4.5 - 9.0
1,428
105
24.0
250
0.0
84
680
3,000
MD605D-05RWI
5
4.5 - 9.0
1,481
105
±5.0
±600
0.0
81
±2,000
3,000
MD605D-12RWI
5
4.5 - 9.0
1,428
105
±12.0
±250
0.0
84
±900
3,000
MD605D-15RWI
5
4.5 - 9.0
1,428
105
±15.0
±200
0.0
84
±660
3,000
MD612S-03RWI
12
9.0 - 18.0
470
55
3.3
1,300
0.0
76
6,600
1,250
MD612S-05RWI
12
9.0 - 18.0
602
55
5.0
1,200
0.0
83
3,300
1,250
MD612S-09RWI
12
9.0 - 18.0
595
55
9.0
666
0.0
84
2,000
1,250
MD612S-12RWI
12
9.0 - 18.0
588
55
12.0
500
0.0
85
1,600
1,250
MD612S-15RWI
12
9.0 - 18.0
588
55
15.0
400
0.0
85
1,400
1,250
MD612S-24RWI
12
9.0 - 18.0
581
55
24.0
250
0.0
86
680
1,250
MD612D-05RWI
12
9.0 - 18.0
609
55
±5.0
±600
0.0
82
±2,000
1,250
MD612D-12RWI
12
9.0 - 18.0
595
55
±12.0
±250
0.0
84
±900
1,250
MD612D-15RWI
12
9.0 - 18.0
581
55
±15.0
±200
0.0
86
±660
1,250
MD624S-03RWI
24
18.0 - 36.0
229
30
3.3
1,300
0.0
78
6,600
750
MD624S-05RWI
24
18.0 - 36.0
301
30
5.0
1,200
0.0
83
3,300
750
MD624S-09RWI
24
18.0 - 36.0
294
30
9.0
666
0.0
85
2,000
750
MD624S-12RWI
24
18.0 - 36.0
294
30
12.0
500
0.0
85
1,600
750
MD624S-15RWI
24
18.0 - 36.0
287
30
15.0
400
0.0
87
1,400
750
MD624S-24RWI
24
18.0 - 36.0
287
30
24.0
250
0.0
87
680
750
MD624D-05RWI
24
18.0 - 36.0
304
30
±5.0
±600
0.0
82
±2,000
750
MD624D-12RWI
24
18.0 - 36.0
297
30
±12.0
±250
0.0
84
±900
750
MD624D-15RWI
24
18.0 - 36.0
297
30
±15.0
±200
0.0
84
±660
750
MD648S-03RWI
48
36.0 - 75.0
117
15
3.3
1,300
0.0
76
6,600
300
MD648S-05RWI
48
36.0 - 75.0
156
15
5.0
1,200
0.0
80
3,300
300
MD648S-09RWI
48
36.0 - 75.0
147
15
9.0
666
0.0
85
2,000
300
MD648S-12RWI
48
36.0 - 75.0
149
15
12.0
500
0.0
84
1,600
300
MD648S-15RWI
48
36.0 - 75.0
145
15
15.0
400
0.0
86
1,400
300
MD648S-24RWI
48
36.0 - 75.0
148
15
24.0
250
0.0
84
680
300
MD648D-05RWI
48
36.0 - 75.0
152
15
±5.0
±600
0.0
82
±2,000
300
MD648D-12RWI
48
36.0 - 75.0
147
15
±12.0
±250
0.0
85
±900
300
MD648D-15RWI
48
36.0 - 75.0
147
15
±15.0
±200
0.0
85
±660
300
For Remote Control option, add suffix “R” to
model number (i.e. MD624S-05RWI-R)
Derating Curve
Notes:
1. Start up time is specified at nominal input and with a constant resistive
load.
2. Cross regulation is measured by monitoring one output set at 100% load
while varying the second output from 25% to 100% load.
3. When measuring output ripple & noise, it is recommended that an external
ceramic capacitor (0.1 µF typ.) be placed from the +VOUT to the -VOUT pins for
single output units and from each output to common for dual output models.
4. Transient recovery is measured to within a 1% error band for a load step
change of 25%.
5. Free air convection is typically 30 - 65 LFM. THe units should not be operated
in still air (0 LFM).
6. Exceeding the absollute ratings could damage the unit.
7. It is recommended that a fuse be used on the input of a power supply for protection.
See the Model Selection table above for the correct rating.
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
Typical Connection
www.micropowerdirect.com
For applications that require meeting EMC standards, the diagram above 5. Recommended values for components are:
7. The output filtering capacitor (C6) is a high frequency, low
illustrates a typical connection of the MD600xRWI series. The units
resistance electrolytic capacitor. Care must be taken in
Component
12 VIN
24 VIN
48 VIN
5 VIN
do not require external components to operate as specified. Some notes
choosing this capacitor not to exceed the capacitive load
C1
220 µF/25V
on this diagram (starting with the input circuit) are:
specification for the unit. Voltage derating of capacitors
22 µF/25V
10 µF/50V
10 µF/50V 2.2 µF/100V
C2
1. An external fuse should be used in all power module applications.
should be 80% or above
The recommended fuse is shown in the model chart on page 2.
8. The drawings below show typical board layouts for the EMI
10 µH
10 µH
10 µH
15 µH
LDM1
2. To protect against a surge, an external MOV is recommended on the
circuit shown above (one for single output models and one
22 µF/25V
10 µF/50V
10 µF/50V 2.2 µF/100V
C3
input. For a suggested value, contact the factory.
for dual output units).
220 pF/3 kV 220 pF/3 kV 220 pF/3 kV 220 pF/3 kV
C4
3. To protect against voltage spikes, it is recommended that a TVS be
9. In many applications simply adding input/output
220 pF/3 kV 220 pF/3 kV 220 pF/3 kV 220 pF/3 kV
C5
used on the input. For a suggested value, contact the factory.
capacitors will enhance the input surge protection
10 µF - 22 µF
C6
4. The filtering components shown are needed to meet the conducted
and reduce output ripple sufficiently. The value of
emissions requirements for EN 55022 Class A.All components should
the input capacitor can range from 220 µF to 330 µF,
6. To meet the requirements of EN 61000-4-4 and EN 61000-4-5, an external input capacitor
be mounted as close to the converter as possible.
depending on the needs of the application. The output
is required for all models. The suggested value is 330 µF/100V. Contact the factory
capacitor would typically be 10 µF.
for more information
Typical Board Layout: With External Filter Components for Single Output Unit
Typical Board Layout: With External Filter Components for Dual Output Unit
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
Remote ON/OFF Control
www.micropowerdirect.com
The MD600x-xxRWI is available with an optional remote control input. This input (pin 3) is
current controlled. The unit operates when this input is open. When the input is “high” (current is flowing into the pin), the converter shuts down. The input current to this pin should be
kept between 2 mA to 4 mA.
The diagram at right shows a simple connection for the control pin.
To order units with the control input, add a “-R” to the model number (i.e. MD605D-12RWI-R).
Remote On/Off
Parameter
Supply On
Supply Off
Standby Input Current
Min.
2
Typ.
Max.
Units
Open or High Impedance
4
mA
2.5
mA
Mechanical Dimensions
Pin Connections
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.5)
• Pin 1 is marked by a “dot” or indentation on the top of the unit
Standard Model
Pin
Single Output
1
-VIN
2
+VIN
3
No Pin
5
No Pin
6
+VOUT
7
-VOUT
8
No Connection
Remote Control Model
Pin
Single Output
1
-VIN
2
+VIN
3
Remote On/Off
5
No Connection
6
+VOUT
7
-VOUT
8
No Connection
Pin
1
2
3
5
6
7
8
Pin
1
2
3
5
6
7
8
Dual Output
-VIN
+VIN
No Connection
No Connection
+VOUT
Common
-VOUT
Dual Output
-VIN
+VIN
Remote On/Off
No Connection
+VOUT
Common
-VOUT
For Remote Control option, add suffix “R” to
model number (i.e. MD624S-05RWI-R)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]