Sensortechnics HCEB001AGBQ8P3 Miniature amplified pressure sensor Datasheet

HCE Series
Miniature amplified pressure sensors
FEATURES
· 10 mbar to 5 bar,
absolute, gage or differential pressure
· Barometric pressure ranges
· Digital SPI bus and analog output
· Precision ASIC signal conditioning
· Calibrated and temperature
compensated
· Matched pressure port volumes
· Miniature SMD housings
· RoHS compliant
· Sensortechnics PRO services
ELECTRICAL CONNECTION
SPECIFICATIONS
Maximum ratings
Supply voltage VS
HCE...3
HCE...5
Output current
Sink
Source
2.7 ... 3.3 VDC
4.5 V ... 5.5 VDC
max. 6.50 VDC
1 mA
1 mA
Lead specifications
Average preheating temperature gradient 2.5 K/s
Soak time
ca. 3 min
Time above 217°C
50 s
Time above 230°C
40 s
Time above 250°C
15 s
Peak temperature
260°C
Cooling temperature gradient
-3.5 K/s
Temperature ranges6
Compensated
Operating
Storage
0 ... 85°C
-25 ... 85°C
-40 ... 125°C
Humidity limits (non-condensing)
0 ... 95 %RH
E / 11652 / A
+Vs
1
Vout
4
5
6
8
3
2
Note:
MISO
CLK
SS
MOSI
GND
Connections for digital SPI bus
(pins 4 to 6) are only available for SMD
package styles (E, H and Q housings).
1/11
www.sensortechnics.com
HCE Series
Miniature amplified pressure sensors
PRESSURE SENSOR CHARACTERISTICS
(TA = 25 °C)
Part no.
Operating pressure
Proof pressure3,5
Burst pressure4,5
HCEM010...B...
HCEM020...B...
HCEM050...B...
HCEM100...B...
HCEM200...B...
HCEM500...B...
HCEB001...B...
HCEM010...U...
HCEM020...U...
HCEM050...U...
HCEM100...U...
HCEM200...U...
HCEM500...U...
HCEB001...U...
HCEB002...U...
HCEB005...U...
HCE0611AR...
HCE0811AR...
0...±10 mbar
0...±20 mbar
0...±50 mbar
0...±100 mbar
0...±200 mbar
0...±500 mbar
0...±1 bar
0...10 mbar
0...20 mbar
0...50 mbar
0...100 mbar
0...200 mbar
0...500 mbar
0...1 bar
0...2 bar
0...5 bar
600...1100 mbar(a)
800...1100 mbar(a)
250 mbar
500 mbar
750 mbar
1.2 bar
2 bar
2 bar
3 bar
250 mbar
500 mbar
750 mbar
1.2 bar
2 bar
2 bar
3 bar
6 bar
7 bar
3 bar
3 bar
500 mbar
750 mbar
1.2 bar
2 bar
2 bar
2 bar
5 bar
500 mbar
750 mbar
1.2 bar
2 bar
2 bar
2 bar
5 bar
7 bar
7 bar
5 bar
5 bar
Other pressure ranges are available on request. Please contact Sensortechnics.
Specification notes:
1. Total accuracy is the combined error from offset and span calibration, linearity, pressure hysteresis, and temperature effects.
Linearity is the measured deviation based on a straight line. Hysteresis is the maximum output difference at any point within
the operating pressure range for increasing and decreasing pressure. Calibration errors include the deviation of offset and
full scale from nominal values.
2. Full Scale Span (FSS) is the algebraic difference between the output signal for the highest and lowest specified pressure.
3. Proof pressure is the maximum pressure which may be applied without causing durable shifts of the electrical parameters
of the sensing element.
4. Burst pressure is the maximum pressure which may be applied without causing damage to the sensing element or leaks to
the housing.
5. The HCE common mode pressure is 2 bar for all devices up to 500 mbar and 7 bar for all other devices. Common mode
pressure is the maximum pressure that can be applied to both ports of a differential pressure sensor simultaneously without
damaging the sensor housing.
6. Extended temperature ranges on request. Please contact Sensortechnics.
7. Max. delay time between pressure change at the pressure die and signal change at the output.
8. The response time depends on the adjusted internal A/D resolution of the sensor. For 14 bit it is typ. 1 ms. Other A/D resolutions
and reponse times are available on request. Please contact Sensortechnics for further information.
9. Sensors with lower current consumption are available on request. Please contact Sensortechnics for further information.
E / 11652 / A
2/11
www.sensortechnics.com
HCE Series
Miniature amplified pressure sensors
PERFORMANCE CHARACTERISTICS
(Vs = 5.0 V, TA = 25 °C, analog output signal is ratiometric to VS, digital output signal is not ratiometric to VS, pressure applied to high pressure port)
All HCE...5 devices (VS = 5.0)
Characteristics
Total accuracy (0...85 °C)1
Min.
Typ.
HCE0611..., HCE0811...
all other devices
Response delay7, 8
A/D resolution8
D/A resolution
Current consumption (no load)9
Max.
Units
±1.0
±0.5
%FSS
1
14
ms
11
5
bi t
mA
HCE...R...5 (barometric devices)
Characteristics
Min.
Typ.
Max.
Unit
D IG IT A L P E R F O R M A N C E C H A R A C T E R IS T IC S
Output at min. specified pressure
Full scale span (FSS)2
Full scale output
0560
6B C 6
0666
6666
6C C C
076C
Count Hex
6D D 2
A N A L O G U E P E R F O R M A N C E C H A R A C T E R IS T IC S
Output at min. specified pressure
Full scale span (FSS)2
Full scale output
0.21
4.21
0.25
4.00
4.25
0.29
4.29
Min.
Typ.
Max.
V
HCE...U...5 (unidirectional devices)
Characteristics
Unit
D IG IT A L P E R F O R M A N C E C H A R A C T E R IS T IC S
Zero pressure offset
Full scale span (FSS)2
Full scale output
05E 3
6C 49
0666
6666
6C C C
06E 9
Count Hex
6D 4F
A N A L O G U E P E R F O R M A N C E C H A R A C T E R IS T IC S
Zero pressure offset
Full scale span (FSS)2
Full scale output
0.23
4.23
0.25
4.00
4.25
0.27
4.27
Min.
Typ.
Max.
V
HCE...B...5 (bidirectional devices)
Characteristics
Unit
D IG IT A L P E R F O R M A N C E C H A R A C T E R IS T IC
Zero pressure offset
Full scale span (FSS)2
Output
3916
at max. specified pressure
at min. specified pressure
6C 49
05E 3
3999
6666
6C C C
0666
3A 1C
6D 4F
06E 9
Count Hex
A N A L O G U E P E R F O R M A N C E C H A R A C T E R IS T IC S
Zero pressure offset
Full scale span (FSS)2
Output
E / 11652 / A
2.23
at max. specified pressure
at min. specified pressure
4.23
0.23
2.25
4.00
4.25
0.25
2.27
4.27
0.27
V
3/11
www.sensortechnics.com
HCE Series
Miniature amplified pressure sensors
PERFORMANCE CHARACTERISTICS
(Vs = 3.0 V, TA = 25 °C, analog output signal is ratiometric to VS, digital output signal is not ratiometric to VS, pressure applied to high pressure port)
All HCE...3 devices (VS = 3.0)
Characteristics
Total accuracy (0...85 °C)1
Min.
Typ.
HCE0611..., HCE0811...
all other devices
Response delay7, 8
A/D resolution8
D/A resolution
Current consumption (no load)9
Max.
Units
±1.0
±0.5
%FSS
1
14
ms
11
3
bi t
mA
HCE...R...3 (barometric devices)
Characteristics
Min.
Typ.
Max.
Unit
D IG IT A L P E R F O R M A N C E C H A R A C T E R IS T IC S
Output at min. specified pressure
Full scale span (FSS)2
Full scale output
09D 0
5F 25
0A A A
5555
5F F F
0B 85
Count Hex
60D 9
A N A L O G U E P E R F O R M A N C E C H A R A C T E R IS T IC S
Output at min. specified pressure
Full scale span (FSS)2
Full scale output
0.23
0.27
2.23
0.25
2.00
2.25
Min.
Typ.
Max.
V
2.27
HCE...U...3 (unidirectional devices)
Characteristics
Unit
D IG IT A L P E R F O R M A N C E C H A R A C T E R IS T IC S
Zero pressure offset
Full scale span (FSS)2
Full scale output
0A 3D
5F 92
0A A A
5555
5F F F
0B 17
Count Hex
606C
A N A L O G U E P E R F O R M A N C E C H A R A C T E R IS T IC S
Zero pressure offset
Full scale span (FSS)2
Full scale output
0.24
0.26
2.24
0.25
2.00
2.25
Min.
Typ.
Max.
V
2.26
HCE...B...3 (bidirectional devices)
Characteristics
Unit
D IG IT A L P E R F O R M A N C E C H A R A C T E R IS T IC
Zero pressure offset
Full scale span (FSS)2
Output
34E 8
at max. specified pressure
at min. specified pressure
5F 92
0A 3D
3555
5555
5F F F
0A A A
35C 2
606C
0B 17
Count Hex
A N A L O G U E P E R F O R M A N C E C H A R A C T E R IS T IC S
Zero pressure offset
Full scale span (FSS)2
Output
E / 11652 / A
1.24
at max. specified pressure
at min. specified pressure
2.24
0.24
1.25
2.00
2.25
0.25
1.26
2.26
0.26
V
4/11
www.sensortechnics.com
HCE Series
Miniature amplified pressure sensors
SPI - SERIAL PERIPHERAL INTERFACE
In general the HCE series supports all combinations of
clock phase (CPHA) and polarity (CPOL). By default it is
programmed to CPHA = 0 and CPOL = 0, which means
that data transmission starts with the rising first clock edge
(see Fig 1).
Introduction
The HCE is capable to generate a digital output signal.
The device runs a cyclic program, which will store a corrected
sensor value with 14 bit resolution about every 500 µs within
the output registers of the internal ASIC. This cyclic program
runs independent from the bus communication. In order to
use the pressure sensor for digital signal readout, it should
be connected to a SPI Master device.
Slave select
The falling edge of the SS line indicates the beginning of
the transfer. Additionally the SS line must not be negated
and reasserted between the three bytes to be transmitted.
SPI specifies four signals: The clock (CLK) is generated by
the master and input to all slaves. MOSI carries data from
master to slave. MISO carries data from slave back to
master. A slave select line (SS) allows individual selection
of a slave device.
Data operation
The MOSI line should always be set to high level. So there
is no data transmission from master to slave. Because of
internal configuration the slave will answer the first byte
with an FFxh. The second and third byte contain the 15 bit
pressure information (see Fig. 2).
SPI Modes
A pair of parameters called clock polarity (CPOL) and clock
phase (CPHA) determine the edges of the clock signal on
which the data are driven and sampled. Each of the two
parameters has two possible states, which allows for four
possible combinations, all of which are incompatible with
one another.
SCK cycle
1
2
3
For further information please refer to
Sensortechnics SPI bus application note
4
5
6
7
8
SCK
(CPOL=0)
MOSI
MSB
MISO
LSB
MSB
LSB
SS
Sampling
Fig. 1:
Example of a standard 1 byte SPI data transfer for CPHA=0 and CPOL=0
Data Byte 1
Data Byte 2
1
1
1
1
1
Data Byte 3
MOSI
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
MISO
X
X
X
X
X
X
X
X
X P14 P13 P12 P11 P10 P9 P8 P7 P6 P5 P4 P3 P2 P1 P0
Relevant data
Fig. 2:
3 byte data stream between HCE sensor and master containing the pressure value as a 15 bit information
E / 11652 / A
5/11
www.sensortechnics.com
HCE Series
Miniature amplified pressure sensors
SPI - SERIAL PERIPHERAL INTERFACE (cont.)
Interface parameters
Parameter
Symbol
Min.
Typ.
Max.
Input high level
90
100
Input low level
0
10
Output low level
Unit
% of V s
10
Pull-up resistor
Ω
500
Load capacitance @ MISO
CMISO
400
Input capacitance @ each pin
CSPI_IN
10
fSCK
100*
MISO hold time after SCK sample slope
tSPI_HD_MISO
200
MOSI setup time before SCK sample slope
tSPI_SU_MOSI
2/fCLK
tSPI_SU_SS
10
Signal clock frequency
/SS setup time before SCK sample slope
640
pF
kHz
ns
ns
* recommended
Note: Sensortechnics recommends communication speeds of at least 100 kHz (max. 640 kHz).
Please contact your nearest Sensortechnics sales office for further information.
t
SPI_SU_SS
t
SPI_SU_MOSI
t
SCK
(CPOL=0)
SPI_HD_MISO
MOSI
MISO
SS
Fig. 3:
Timing characteristics
E / 11652 / A
6/11
www.sensortechnics.com
HCE Series
Miniature amplified pressure sensors
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTIONS
HCE...E8...
SMD dual port, same side
Straight ports
12.70
Bottom view
4.50
6.50
1.28
16
3
5 6 7 8
4 3 2 1
4.06
10.70
4.20
3
Connection
1
+Vs
2
GND
3
Vout
4
MISO
5
C LK
6
SS
7
I/C *
8
MOSI
* Internal connection.
Do not connect for any reason
6.70
3
1.90
2
HIGH PRESSURE PORT
Pin
0.46
LOW PRESSURE PORT
third angle projection
2.54
dimensions in mm
HCE...E9...
12.70
Pin
4.67
00
7.
5 6 7 8
4 3 2 1
2.50 ±0.2
5 ±0.2
10.70
3,12
HIGH PRESSURE PORT
4.0
Connection
1
+Vs
2
GND
3
Vout
4
MISO
5
C LK
6
SS
7
I/C *
8
MOSI
5.21
6.87
* Internal connection.
Do not connect for any reason
third angle projection
LOW PRESSURE PORT
2.54
E / 11652 / A
2.0
16
Ø 3.0 ±0.1
Ø 2.20 ±0.1
Bottom view
Ø 2.20 ±0.1
SMD dual port, same side
Barbed ports
0.46
dimensions in mm
7/11
www.sensortechnics.com
HCE Series
Miniature amplified pressure sensors
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTIONS (cont.)
HCE...H8...
SMD single port
Straight port
Top view
12.70
Pin
1
+Vs
8 7 6 5
2
GND
Vout
MISO
5
C LK
6
SS
1 2 3 4
7
I/C *
10.70
8
MOSI
2
3
4
9.50
16
1.28
4.06
Connection
2.54
HIGH PRESSURE PORT
3.70
3
1.90
0.46
* Internal connection.
Do not connect for any reason
third angle projection
3
4.2
dimensions in mm
HCE...H9...
SMD single port
Barbed port
Top view
Pin
Connection
12.7
1
+Vs
2
GND
3
Vout
4
MISO
5
C LK
6
SS
7
I/C *
8
MOSI
10.5
16.0
8 7 6 5
1 2 3 4
3.8
10.7
6.2
E / 11652 / A
Ø 3.0
third angle projection
6.0
Ø 2.2
2.8
9.0
HIGH PRESSURE PORT
* Internal connection.
Do not connect for any reason
dimensions in mm
8/11
www.sensortechnics.com
HCE Series
Miniature amplified pressure sensors
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTIONS (cont.)
HCE...Q8...
SMD dual port, opposite side
Straight ports
12.70
Bottom view
1.28
9.50
16
2
5 6 7 8
4 3 2 1
4.06
10.70
4.20
3
+Vs
2
GND
3
Vout
4
MISO
5
C LK
6
SS
7
I/C *
8
MOSI
6.70
3
Connection
1
* Internal connection.
Do not connect for any reason
LOW PRESSURE PORT
HIGH PRESSURE PORT
1.90
Pin
third angle projection
0.46
2.54
dimensions in mm
HCE...Q9...
SMD dual port, opposite side
Barbed ports
Top view
6.2
4.0
Pin
16
10.5
12.7
8 7 6 5
1 2 3 4
3.1
10.7
6.9
LOW PRESSURE PORT
1
+Vs
2
GND
3
Vout
4
MISO
5
C LK
6
SS
7
I/C *
8
MOSI
* Internal connection.
Do not connect for any reason
6.0
E / 11652 / A
Ø 2.2
Ø 3.0
2.2
5.0
HIGH PRESSURE PORT
Connection
third angle projection
dimensions in mm
9/11
www.sensortechnics.com
HCE Series
Miniature amplified pressure sensors
HOUSING OPTIONS
Different housing options are available on request. Please contact Sensortechnics.
Dual Inline Packages (DIP)
(Sample package shown: DIP dual port, same side)
12.70
4.50
6.50
16.0
16.25
3.0
5 6 7 8
4 3 2 1
9.0
10.70
3.0
4.20
HIGH PRESSURE PORT
LOW PRESSURE PORT
2.54
0.46
5.60
1.90
2.0
6.70
3.0
third angle projection
dimensions in mm
Single Inline Packages (SIL)
(Sample package shown: SIL same top side)
12.70
6.70
7.85
4.85
3
2
10.30
16
10.70
4.20
3
1.90
4 3 2 1
0.25
0.51
1.45
2.54
HIGH PRESSURE PORT
1.90
10.70
third angle projection
dimensions in mm
LOW PRESSURE PORT
E / 11652 / A
10/11
www.sensortechnics.com
HCE Series
Miniature amplified pressure sensors
ORDERING INFORMATION
Series
Options
HCE
Pressure range
Pressure mode
600...1100 mbar A* Absolute
B
Bidirectional
0811
800...1100 mbar D
Differential
U
Unidirectional
Gage
R* Barometric
M010
10 mbar G
M020
20 mbar
M050
50 mbar
M100
100 mbar
M200
200 mbar
M500
500 mbar
B 001
1 bar
(B001A)
1 bara
B 002
2 bar
B 005
5 bar
Note:
HCE
M050
Housing
E*
D
* for pressure ranges
0611, 0811
B
Porting
SMD, 2 ports,
same side
8* Straight
Grade
P Prime
9** Barbed
Voltage
3
3V
5
5V
H** SMD, 1 port
Q*
* only available for
pressure ranges
0611, 0811,
B 001, B 002
Example:
Calibration
0611
SMD, 2 ports,
opposite side
Housings Q only available * standard for
up to 1 bar. Please
devices up to
500 mbar and
contact Sensortechnics.
barometric ranges
* standard for differential ** standard for
devices, "D"
devices from
** standard for absolute
1 bar
and gage devices,
"A" and "G"
E
8
P
5
Devices highlighted in grey are preferred stock items
Custom specific pressure ranges and mechanical or electronic sensor modifications
are widely available:
· I2C, switching and custom specific outputs
· Dual inline packages (DIP)
· Single inline packages (SIL)
... etc.
Please contact your nearest Sensortechnics sales office for further information.
Sensortechnics PRO services:
· Extended guarantee period of 2 years
· Custom product modifications and adaptations even for small quantities
· Advanced logistics models for supply inventory and short delivery times
· Technical support through application engineers on the phone or at your site
· Traceability of each sensor through serial numbers on request
· No product specification changes without customer notification
· No product obsolescence without very early prior notice
· Fastest possible technical response for design and QA engineers
· Long term product availability for your spares and service needs
... plus other services on request
Sensortechnics reserve the right to make changes to any products herein. Sensortechnics do not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
E / 11652 / A
11/11
www.sensortechnics.com
Similar pages