STMicroelectronics M29W641DH10N1E 64 mbit 4mb x16, uniform block 3v supply flash memory Datasheet

M29W641DH, M29W641DL
M29W641DU
64 Mbit (4Mb x16, Uniform Block)
3V Supply Flash Memory
PRODUCT PREVIEW
FEATURES SUMMARY
■ SUPPLY VOLTAGE
Figure 1. Packages
– VCC = 2.7V to 3.6V Core Power Supply
– VCCQ = 1.8V to 3.6V for Input/Output
■
– VPP =12 V for Fast Program (optional)
ACCESS TIME: 70, 90, 100 and 120ns
■
PROGRAMMING TIME
– 10 µs typical
– Double Word Program option
■
128 UNIFORM, 32-KWord MEMORY BLOCKS
■
PROGRAM/ERASE CONTROLLER
TSOP48 (N)
12 x 20mm
– Embedded Program and Erase algorithms
■
ERASE SUSPEND and RESUME MODES
– Read and Program another Block during
Erase Suspend
■
UNLOCK BYPASS PROGRAM COMMAND
– Faster Production/Batch Programming
■
FBGA
WRITE PROTECT OPTIONS
– M29W641DH: WP Pin for Write Protection of
Highest Address Block
– M29W641DL: WP Pin for Write Protection of
Lowest Address Block
– M29W641DU: No Write Protection
■ TEMPORARY BLOCK UNPROTECTION
MODE
■
COMMON FLASH INTERFACE
■
EXTENDED MEMORY BLOCK
TFBGA63 (ZA)
7 x 11mm
– Extra block used as security block or to store
additional information
■
LOW POWER CONSUMPTION
– Standby and Automatic Standby
■
ELECTRONIC SIGNATURE
– Manufacturer Code: 0020h
– Device Code M29W641D: 22C7h
April 2003
This is preliminary information on a new product now in development. Details are subject to change without notice.
1/42
M29W641DH, M29W641DL, M29W641DU
TABLE OF CONTENTS
SUMMARY DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Figure 2. Logic Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Table 1. Signal Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Figure 3. TSOP Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Figure 4. TFGBA Connections (Top view through package) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
SIGNAL DESCRIPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Address Inputs (A0-A21). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Data Inputs/Outputs (DQ0-DQ7). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Data Inputs/Outputs (DQ8-DQ15). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Chip Enable (E). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Output Enable (G). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Write Enable (W). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Write Protect (WP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Reset/Block Temporary Unprotect (RP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
VPP (VPP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
VCC Supply Voltage (2.7V to 3.6V).. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
VCCQ Supply Voltage (1.8V to 3.6V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
VSS Ground. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Table 2. Bus Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
BUS OPERATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Bus Read. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Bus Write. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Output Disable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Standby. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Automatic Standby. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Special Bus Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Electronic Signature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Block Protect and Chip Unprotect. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Block Protect and Chip Unprotect. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
COMMAND INTERFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Read/Reset Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Auto Select Command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Program Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Unlock Bypass Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Unlock Bypass Program Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Unlock Bypass Reset Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Chip Erase Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Block Erase Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Erase Suspend Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Erase Resume Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2/42
M29W641DH, M29W641DL, M29W641DU
Enter Extended Block Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Exit Extended Block Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Table 3. Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Table 4. Program, Erase Times and Program, Erase Endurance Cycles . . . . . . . . . . . . . . . . . . . . 14
STATUS REGISTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Data Polling Bit (DQ7). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Toggle Bit (DQ6).. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Error Bit (DQ5). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Erase Timer Bit (DQ3). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Alternative Toggle Bit (DQ2).. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Table 5. Status Register Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Figure 5. Data Polling Flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Figure 6. Data Toggle Flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
MAXIMUM RATING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Table 6. Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
DC and AC PARAMETERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Table 7. Operating and AC Measurement Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Figure 7. AC Measurement I/O Waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Figure 8. AC Measurement Load Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Table 8. Device Capacitance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Table 9. DC Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Figure 9. Read Mode AC Waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Table 10. Read AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Figure 10. Write AC Waveforms, Write Enable Controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Table 11. Write AC Characteristics, Write Enable Controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Figure 11. Write AC Waveforms, Chip Enable Controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Table 12. Write AC Characteristics, Chip Enable Controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Figure 12. Reset/Block Temporary Unprotect AC Waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Table 13. Reset/Block Temporary Unprotect AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Figure 13. Accelerated Program Timing Waveforms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
PACKAGE MECHANICAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Figure 14. TSOP48 – 48 lead Plastic Thin Small Outline, 12 x 20mm, Package Outline . . . . . . . . 25
Table 14. TSOP48 – 48 lead Plastic Thin Small Outline, 12 x 20mm, Package Mechanical Data . 25
Figure 15. TFBGA63 - 7x11mm, 6x8 active ball array, 0.8mm pitch, Bottom view package outline 26
Table 15. TFBGA63 - 7x11mm, 6x8 active ball array, 0.8mm pitch, Package Mechanical Data . . 26
PART NUMBERING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Table 16. Ordering Information Scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
APPENDIX A. BLOCK ADDRESSES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Table 17. Block Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
3/42
M29W641DH, M29W641DL, M29W641DU
APPENDIX B. COMMON FLASH INTERFACE (CFI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Table 18. Query Structure Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Table 19. CFI Query Identification String . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Table 20. CFI Query System Interface Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Table 21. Device Geometry Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Table 22. Primary Algorithm-Specific Extended Query Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Table 23. Security Code Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
APPENDIX C. EXTENDED MEMORY BLOCK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Factory Locked Extended Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Customer Lockable Extended Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Table 24. Extended Block Address and Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
APPENDIX D. BLOCK PROTECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Programmer Technique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
In-System Technique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Table 25. Programmer Technique Bus Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Figure 16. Programmer Equipment Group Protect Flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Figure 17. Programmer Equipment Chip Unprotect Flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Figure 18. In-System Equipment Group Protect Flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Figure 19. In-System Equipment Chip Unprotect Flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
REVISION HISTORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Table 26. Document Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
4/42
M29W641DH, M29W641DL, M29W641DU
SUMMARY DESCRIPTION
The M29W641D is a 64 Mbit (4Mb x16) non-volatile memory that can be read, erased and reprogrammed. These operations can be performed
using a single, low voltage, 2.7V to 3.6V VCC supply for the circuitry and a 1.8V to 3.6V VCCQ supply
for the Input/Output pins. An optional 12 V VPP
power supply is provided to speed up customer
programming.
On power-up the memory defaults to its Read
mode where it can be read in the same way as a
ROM or EPROM.
The highest address block of the M29W641DH or
the lowest address block of the M29W641DL can
be protected from accidental programming or erasure using the WP pin (if WP = VIL). The
M29W641DU does not feature the WP pin.
Each block can be erased independently so it is
possible to preserve valid data while old data is
erased. The blocks can be protected to prevent
accidental Program or Erase commands from
modifying the memory. Program and Erase commands are written to the Command Interface of
the memory. An on-chip Program/Erase Controller
simplifies the process of programming or erasing
the memory by taking care of all of the special operations that are required to update the memory
contents. The end of a program or erase operation
can be detected and any error conditions identified. The command set required to control the
memory is consistent with JEDEC standards.
The M29W641D has an extra block, the Extended
Block, (of 32 KWords) that can be accessed using
a dedicated command. The Extended Block can
be protected and so is useful for storing security
information. However the protection is not reversible, once protected the protection cannot be undone.
Chip Enable, Output Enable and Write Enable signals control the bus operation of the memory.
They allow simple connection to most microprocessors, often without additional logic.
The memory is offered in a 48-pin TSOP package
(M29W641DL and M29W641DH) or in a 63-ball TFBGA package (M29W641DU). All devices are delivered with all the bits erased (set to 1).
Figure 2. Logic Diagram
VCC
VCCQ
VPP
22
16
A0-A21
DQ0-DQ15
W
E
M29W641D
G
RB
RP
WP
VSS
AI06697b
Table 1. Signal Names
A0-A21
Address Inputs
DQ0-DQ7
Data Inputs/Outputs
DQ8DQ15
Data Inputs/Outputs
E
Chip Enable
G
Output Enable
W
Write Enable
RP
Reset/Block Temporary Unprotect
(M29W641DH and M29W641DL only)
RB
Ready/Busy Output (M29W641DU
only)
WP
Write Protect
VCC
Supply Voltage
VCCQ
Supply Voltage for Input/Output
VPP
Supply Voltage for Fast Program
(optional)
VSS
Ground
5/42
M29W641DH, M29W641DL, M29W641DU
Figure 3. TSOP Connections
A15
A14
A13
A12
A11
A10
A9
A8
A21
A20
W
RP
VPP
WP
A19
A18
A17
A7
A6
A5
A4
A3
A2
A1
1
12
13
24
48
M29W641D
37
36
25
AI06698
6/42
A16
VCCQ
VSS
DQ15
DQ7
DQ14
DQ6
DQ13
DQ5
DQ12
DQ4
VCC
DQ11
DQ3
DQ10
DQ2
DQ9
DQ1
DQ8
DQ0
G
VSS
E
A0
M29W641DH, M29W641DL, M29W641DU
Figure 4. TFGBA Connections (Top view through package)
1
2
A
NC(1)
NC(1)
B
NC(1)
3
4
5
6
7
8
NC(1)
NC(1)
NC(1)
NC(1)
C
A3
A7
RB
W
A9
A13
D
A4
A17
VPP
RP
A8
A12
E
A2
A6
A18
A21
A10
A14
F
A1
A5
A20
A19
A11
A15
G
A0
DQ0
DQ2
DQ5
DQ7
A16
H
E
DQ8
DQ10
DQ12
DQ14
VCCQ
J
G
DQ9
DQ11
VCC
DQ13
DQ15
K
VSS
DQ1
DQ3
DQ4
DQ6
VSS
L
NC(1)
NC(1)
NC(1)
NC(1)
M
NC(1)
NC(1)
NC(1)
NC(1)
AI06879
Note: 1. Balls are shorted together via the substrate but not connected to the die.
7/42
M29W641DH, M29W641DL, M29W641DU
SIGNAL DESCRIPTIONS
See Figure 2, Logic Diagram, and Table 1, Signal
Names, for a brief overview of the signals connected to this device.
Address Inputs (A0-A21). The Address Inputs
select the cells in the memory array to access during Bus Read operations. During Bus Write operations they control the commands sent to the
Command Interface of the Program/Erase Controller.
Data Inputs/Outputs (DQ0-DQ7). The Data I/O
outputs the data stored at the selected address
during a Bus Read operation. During Bus Write
operations they represent the commands sent to
the Command Interface of the Program/Erase
Controller.
Data Inputs/Outputs (DQ8-DQ15). The Data I/O
outputs the data stored at the selected address
during a Bus Read operation. During Bus Write
operations the Command Register does not use
these bits. When reading the Status Register
these bits should be ignored.
Chip Enable (E). The Chip Enable, E, activates
the memory, allowing Bus Read and Bus Write operations to be performed. When Chip Enable is
High, V IH, all other pins are ignored.
Output Enable (G). The Output Enable, G, controls the Bus Read operation of the memory.
Write Enable (W). The Write Enable, W, controls
the Bus Write operation of the memory’s Command Interface.
Write Protect (WP). The Write Protect pin is
available in the M29W641DH and M29W641DL
only. It provides a hardware method of protecting
the highest address block for the M29W641DH
and the lowest address block for the
M29W641DL. The Write Protect pin must not be
left floating or unconnected.
When Write Protect is Low, VIL , the memory protects either the highest or lowest address block;
Program and Erase operations in this block are ignored while Write Protect is Low.
When Write Protect is High, VIH, the memory reverts to the previous protection status for this
block. Program and Erase operations can now
modify the data in this block unless the block is
protected using Block Protection.
Ready/Busy Output (RB). The Ready/Busy pin
is an open-drain output that can be used to identify
when the device is performing a Program or Erase
operation. During Program or Erase operations
Ready/Busy is Low, V OL. Ready/Busy is high-impedance during Read mode, Auto Select mode
and Erase Suspend mode.
After a Hardware Reset, Bus Read and Bus Write
operations cannot begin until Ready/Busy be-
8/42
comes high-impedance. See Table 13 and Figure
12, Reset/Block Temporary Unprotect AC Characteristics.
The use of an open-drain output allows the Ready/
Busy pins from several memories to be connected
to a single pull-up resistor. A Low will then indicate
that one, or more, of the memories is busy.
Reset/Block Temporary Unprotect (RP). The
Reset/Block Temporary Unprotect pin can be
used to apply a Hardware Reset to the memory or
to temporarily unprotect all Blocks that have been
protected.
Note that if Write Protect (WP) is at V IL, then one
of the two outermost blocks will remain protected
even if RP is at V ID.
A Hardware Reset is achieved by holding Reset/
Block Temporary Unprotect Low, V IL, for at least
tPLPX. After Reset/Block Temporary Unprotect
goes High, V IH, the memory will be ready for Bus
Read and Bus Write operations after tPHEL or
tRHEL, whichever occurs last. See Table 13 and
Figure 12, Reset/Block Temporary Unprotect AC
Characteristics, for more details.
Holding RP at V ID will temporarily unprotect the
protected Blocks in the memory. Program and
Erase operations on all blocks will be possible.
The transition from VIH to VID must be slower than
tPHPHH.
VPP (VPP). When the VPP pin is raised to VPPH
the memory automatically enters the Unlock Bypass mode. When the pin is returned to V IH or VIL
normal operation resumes. During Unlock Bypass
Program operations the memory draws IPP from
the pin to supply the programming circuits. See the
description of the Unlock Bypass command in the
Command Interface section. The transitions from
VIH to V PP and from V PP to VIH must be slower
than tVHVPP, see Figure 13.
Never raise the pin to VPP from any mode except
Read mode, otherwise the memory may be left in
an indeterminate state.
VCC Supply Voltage (2.7V to 3.6V). VCC
provides the power supply for all operations (Read,
Program and Erase).
The Command Interface is disabled when the V CC
Supply Voltage is less than the Lockout Voltage,
VLKO. This prevents Bus Write operations from accidentally damaging the data during power up,
power down and power surges. If the Program/
Erase Controller is programming or erasing during
this time then the operation aborts and the memory contents being altered will be invalid.
VCCQ Supply Voltage (1.8V to 3.6V). VCCQ provides the power supply to the I/O pins and enables
all Outputs to be powered independently of VCC.
M29W641DH, M29W641DL, M29W641DU
0.1µF ceramic capacitor close to the pin for
current surge protection (high frequency, inherently low inductance capacitors should be
as close as possible to the device). See Figure
8, AC Measurement Load Circuit. The PCB
trace widths should be sufficient to carry the
required V PP program and erase currents. See
Table 9, DC Characteristics.
VCCQ can be tied to VCC or can use a separate
supply.
VSS Ground. VSS is the reference for all voltage
measurements. The device features two V SS pins
which must be both connected to the system
ground.
Note: Each device in a system should have
VCC, VCCQ and VPP decoupled from VSS with a
Table 2. Bus Operations
Operation
Address Inputs
A0-A21
Data Inputs/Outputs
DQ15-DQ0
E
G
W
Bus Read
VIL
VIL
VIH
Cell Address
Bus Write
VIL
VIH
VIL
Command Address
X
VIH
VIH
X
Hi-Z
Standby
VIH
X
X
X
Hi-Z
Read Manufacturer
Code
VIL
VIL
VIH
A0 = VIL, A1 = VIL, A9 = VID,
Others VIL or VIH
0020h
Read Device Code
VIL
VIL
VIH
A0 = VIH, A1 = VIL, A9 = VID,
Others VIL or VIH
22C7h
Output Disable
Extended Memory
Block Verify Code
VIL
VIL
VIH
A0 = VIH, A1 = VIH, A6 = VIL,
A9 = VID, Others VIL or VIH
Data Output
Data Input
98h (factory locked, WP protects
highest address block)
18h (not factory locked, WP
protects highest address
block)
88h (factory locked, WP protects
lowest block)
08h (not factory locked, WP
protects lowest block)
Note: X = VIL or VIH.
9/42
M29W641DH, M29W641DL, M29W641DU
BUS OPERATIONS
There are five standard bus operations that control
the device. These are Bus Read, Bus Write, Output Disable, Standby and Automatic Standby. See
Table 2, Bus Operations, for a summary. Typically
glitches of less than 5ns on Chip Enable or Write
Enable are ignored by the memory and do not affect bus operations.
Bus Read. Bus Read operations read from the
memory cells, or specific registers in the Command Interface. A valid Bus Read operation involves setting the desired address on the Address
Inputs, applying a Low signal, V IL, to Chip Enable
and Output Enable and keeping Write Enable
High, VIH. The Data Inputs/Outputs will output the
value, see Figure 9, Read Mode AC Waveforms,
and Table 10, Read AC Characteristics, for details
of when the output becomes valid.
Bus Write. Bus Write operations write to the
Command Interface. A valid Bus Write operation
begins by setting the desired address on the Address Inputs. The Address Inputs are latched by
the Command Interface on the falling edge of Chip
Enable or Write Enable, whichever occurs last.
The Data Inputs/Outputs are latched by the Command Interface on the rising edge of Chip Enable
or Write Enable, whichever occurs first. Output Enable must remain High, VIH, during the whole Bus
Write operation. See Figure 10 and Figure 11,
Write AC Waveforms, and Table 11 and Table 12,
Write AC Characteristics, for details of the timing
requirements.
Output Disable. The Data Inputs/Outputs are in
the high impedance state when Output Enable is
High, V IH.
Standby. When Chip Enable is High, VIH, the
memory enters Standby mode and the Data Inputs/Outputs pins are placed in the high-impedance state. To reduce the Supply Current to the
Standby Supply Current, ICC2, Chip Enable should
10/42
be held within VCC ± 0.2V. For the Standby current
level see Table 9, DC Characteristics.
During program or erase operations the memory
will continue to use the Program/Erase Supply
Current, ICC3, for Program or Erase operations until the operation completes.
Automatic Standby. If CMOS levels (VCC ± 0.2V)
are used to drive the bus and the bus is inactive for
300ns or more the memory enters Automatic
Standby where the internal Supply Current is reduced to the Standby Supply Current, ICC2. The
Data Inputs/Outputs will still output data if a Bus
Read operation is in progress.
Special Bus Operations
Additional bus operations can be performed to
read the Electronic Signature and also to apply
and remove Block Protection. These bus operations are intended for use by programming equipment and are not usually used in applications.
They require VID to be applied to some pins.
Electronic Signature. The memory has two
codes, the manufacturer code and the device
code, that can be read to identify the memory.
These codes can be read by applying the signals
listed in Table 2, Bus Operations.
Block Protect and Chip Unprotect. Groups
of
blocks can be protected against accidental Program or Erase. The whole chip can be unprotected
to allow the data inside the blocks to be changed.
Write Protect (WP) can be used to protect one of
the outermost blocks. When Write Protect (WP) is
at V IL one of the two outermost blocks is protected and remains protected regardless of the Block
Protection Status or the Reset/Block Temporary
Unprotect pin status. For the M29W641DH, it is
the highest addressed block that can be protected. For the M29W641DL, it is the lowest.
Block Protect and Chip Unprotect operations are
described in Appendix D.
M29W641DH, M29W641DL, M29W641DU
COMMAND INTERFACE
All Bus Write operations to the memory are interpreted by the Command Interface. Commands
consist of one or more sequential Bus Write operations. Failure to observe a valid sequence of Bus
Write operations will result in the memory returning to Read mode. The long command sequences
are imposed to maximize data security.
See Table 3 for a summary of the commands.
Read/Reset Command
The Read/Reset command returns the memory to
its Read mode where it behaves like a ROM or
EPROM. It also resets the errors in the Status
Register. Either one or three Bus Write operations
can be used to issue the Read/Reset command.
The Read/Reset command can be issued, between Bus Write cycles before the start of a program or erase operation, to return the device to
read mode. If the Read/Reset command is issued
during the timeout of a Block erase operation then
the memory will take up to 10µs to abort. During
the abort period no valid data can be read from the
memory. The Read/Reset command will not abort
an Erase operation when issued while in Erase
Suspend.
Auto Select Command
The Auto Select command is used to read the
Manufacturer Code, the Device Code, the Block
Protection Status and the Extended Memory Block
Verify Code. Three consecutive Bus Write operations are required to issue the Auto Select command. Once the Auto Select command is issued
the memory remains in Auto Select mode until a
Read/Reset command is issued. Read CFI Query
and Read/Reset commands are accepted in Auto
Select mode, all other commands are ignored.
In Auto Select mode the Manufacturer Code can
be read using a Bus Read operation with A0 = V IL
and A1 = VIL. The other address bits may be set to
either VIL or VIH. The Manufacturer Code for STMicroelectronics is 0020h.
The Device Code can be read using a Bus Read
operation with A0 = VIH and A1 = VIL. The other
address bits may be set to either V IL or VIH. The
Device Code for the M29W641D is 22C7h.
The Block Protection Status of each block can be
read using a Bus Read operation with A0 = V IL ,
A1 = V IH, and A12-A21 specifying the address of
the block. The other address bits may be set to either V IL or VIH. If the addressed block is protected
then 01h is output on Data Inputs/Outputs DQ0DQ7, otherwise 00h is output.
Read CFI Query Command
The Read CFI Query Command is used to read
data from the Common Flash Interface (CFI)
Memory Area. This command is valid when the de-
vice is in the Read Array mode, or when the device
is in Autoselected mode.
One Bus Write cycle is required to issue the Read
CFI Query Command. Once the command is issued subsequent Bus Read operations read from
the Common Flash Interface Memory Area.
The Read/Reset command must be issued to return the device to the previous mode (the Read Array mode or Autoselected mode). A second Read/
Reset command would be needed if the device is
to be put in the Read Array mode from Autoselected mode.
See Appendix B, Table 18 to Table 23 for details
on the information contained in the Common Flash
Interface (CFI) memory area.
Program Command
The Program command can be used to program a
value to one address in the memory array at a
time. The command requires four Bus Write operations, the final write operation latches the address and data, and starts the Program/Erase
Controller.
If the address falls in a protected block then the
Program command is ignored, the data remains
unchanged. The Status Register is never read and
no error condition is given.
During the program operation the memory will ignore all commands. It is not possible to issue any
command to abort or pause the operation. Typical
program times are given in Table 4. Bus Read operations during the program operation will output
the Status Register on the Data Inputs/Outputs.
See the section on the Status Register for more
details.
After the program operation has completed the
memory will return to the Read mode, unless an
error has occurred. When an error occurs the
memory will continue to output the Status Register. A Read/Reset command must be issued to reset the error condition and return to Read mode.
Note that the Program command cannot change a
bit set at ’0’ back to ’1’. One of the Erase Commands must be used to set all the bits in a block or
in the whole memory from ’0’ to ’1’.
Fast Program Commands
There is a Fast Program command available to improve the programming throughput, by writing several adjacent words or bytes in parallel: the Double
Word Program command.
Double Word Program Command. The Double
Word Program command is used to write a page
of two adjacent words in parallel. The two words
must differ only for the address A0.
Three bus write cycles are necessary to issue the
Double Word Program command.
11/42
M29W641DH, M29W641DL, M29W641DU
■
■
■
The first bus cycle sets up the Double Word
Program Command.
The second bus cycle latches the Address and
the Data of the first word to be written.
The third bus cycle latches the Address and the
Data of the second word to be written and starts
the Program/Erase Controller.
Only one bank can be programmed at any one
time. The other bank must be in Read mode or
Erase Suspend.
Programming should not be attempted when VPP
is not at V PPH.
After programming has started, Bus Read operations in the Bank being programmed output the
Status Register content, while Bus Read operations to the other Bank output the contents of the
memory array.
After the program operation has completed the
memory will return to the Read mode, unless an
error has occurred. When an error occurs Bus
Read operations to the Bank where the command
was issued will continue to output the Status Register. A Read/Reset command must be issued to
reset the error condition and return to Read mode.
Note that the Fast Program commands cannot
change a bit set at ’0’ back to ’1’. One of the Erase
Commands must be used to set all the bits in a
block or in the whole memory from ’0’ to ’1’.
Typical Program times are given in Table 4, Program, Erase Times and Program, Erase Endurance Cycles.
Unlock Bypass Command
The Unlock Bypass command is used in conjunction with the Unlock Bypass Program command to
program the memory faster than with the standard
program commands. When the cycle time to the
device is long (as with some EPROM programmers) considerable time saving can be made by
using these commands. Three Bus Write operations are required to issue the Unlock Bypass
command.
Once the Unlock Bypass command has been issued the memory enters Unlock Bypass mode.
When in this mode the memory can be read as if
in Read mode.
When V PPH is applied to the VPP pin the memory
automatically enters the Unlock Bypass mode and
the Unlock Bypass Program command can be issued immediately.
Unlock Bypass Program Command
The Unlock Bypass Program command can be
used to program one address in the memory array
at a time. The command requires two Bus Write
operations, the final write operation latches the ad-
12/42
dress and data, and starts the Program/Erase
Controller.
A Program operation initiated by issuing the Unlock Bypass Program command is identical to a
Program operation initiated by issuing the Program command. It cannot be aborted and a Bus
Read operation will output the Status Register.
See the Program Command paragraph for further
details.
Unlock Bypass Reset Command
The Unlock Bypass Reset command can be used
to return to Read/Reset mode from Unlock Bypass
Mode. Two Bus Write operations are required to
issue the Unlock Bypass Reset command. Read/
Reset command does not exit from Unlock Bypass
Mode.
Chip Erase Command
The Chip Erase command can be used to erase
the entire chip. Six Bus Write operations are required to issue the Chip Erase Command and start
the Program/Erase Controller.
If any blocks are protected then these are ignored
and all the other blocks are erased. If all of the
blocks are protected the Chip Erase operation appears to start but will terminate within about 100µs,
leaving the data unchanged. No error condition is
given when protected blocks are ignored.
During the erase operation the memory will ignore
all commands, including the Erase Suspend command. It is not possible to issue any command to
abort the operation. Typical chip erase times are
given in Table 4. All Bus Read operations during
the Chip Erase operation will output the Status
Register on the Data Inputs/Outputs. See the section on the Status Register for more details.
After the Chip Erase operation has completed the
memory will return to the Read Mode, unless an
error has occurred. When an error occurs the
memory will continue to output the Status Register. A Read/Reset command must be issued to reset the error condition and return to Read Mode.
The Chip Erase Command sets all of the bits in unprotected blocks of the memory to ’1’. All previous
data is lost.
Block Erase Command
The Block Erase command can be used to erase
a list of one or more blocks. Six Bus Write operations are required to select the first block in the list.
Each additional block in the list can be selected by
repeating the sixth Bus Write operation using the
address of the additional block. The Block Erase
operation starts the Program/Erase Controller
about 50µs after the last Bus Write operation.
Once the Program/Erase Controller starts it is not
possible to select any more blocks. Each additional block must therefore be selected within 50µs of
M29W641DH, M29W641DL, M29W641DU
the lowest address block. The 50µs timer restarts
when an additional block is selected. The Status
Register can be read after the sixth Bus Write operation. See the Status Register section for details
on how to identify if the Program/Erase Controller
has started the Block Erase operation.
If any selected blocks are protected then these are
ignored and all the other selected blocks are
erased. If all of the selected blocks are protected
the Block Erase operation appears to start but will
terminate within about 100µs, leaving the data unchanged. No error condition is given when protected blocks are ignored.
During the Block Erase operation the memory will
ignore all commands except the Erase Suspend
command. Typical block erase times are given in
Table 4. All Bus Read operations during the Block
Erase operation will output the Status Register on
the Data Inputs/Outputs. See the section on the
Status Register for more details.
After the Block Erase operation has completed the
memory will return to the Read Mode, unless an
error has occurred. When an error occurs the
memory will continue to output the Status Register. A Read/Reset command must be issued to reset the error condition and return to Read mode.
The Block Erase Command sets all of the bits in
the unprotected selected blocks to ’1’. All previous
data in the selected blocks is lost.
Erase Suspend Command
The Erase Suspend Command may be used to
temporarily suspend a Block Erase operation and
return the memory to Read mode. The command
requires one Bus Write operation.
The Program/Erase Controller will suspend within
the Erase Suspend Latency time of the Erase Suspend Command being issued. Once the Program/
Erase Controller has stopped the memory will be
set to Read mode and the Erase will be suspended. If the Erase Suspend command is issued during the period when the memory is waiting for an
additional block (before the Program/Erase Controller starts) then the Erase is suspended immediately and will start immediately when the Erase
Resume Command is issued. It is not possible to
select any further blocks to erase after the Erase
Resume.
During Erase Suspend it is possible to Read and
Program cells in blocks that are not being erased;
both Read and Program operations behave as
normal on these blocks. If any attempt is made to
program in a protected block or in the suspended
block then the Program command is ignored and
the data remains unchanged. The Status Register
is not read and no error condition is given. Reading from blocks that are being erased will output
the Status Register.
It is also possible to issue the Auto Select, Read
CFI Query and Unlock Bypass commands during
an Erase Suspend. The Read/Reset command
must be issued to return the device to Read Array
mode before the Resume command will be accepted.
Erase Resume Command
The Erase Resume command must be used to restart the Program/Erase Controller after an Erase
Suspend. The device must be in Read Array mode
before the Resume command will be accepted. An
erase can be suspended and resumed more than
once.
Enter Extended Block Command
The device has an extra 32 KWord block (Extended Block) that can only be accessed using the Enter Extended Block command. Three Bus write
cycles are required to issue the Extended Block
command. Once the command has been issued
the device enters Extended Block mode where all
Bus Read or Write operations to the Boot Block
addresses access the Extended Block. The Extended Block (with the same address as the Boot
Blocks) cannot be erased, and can be treated as
one-time programmable (OTP) memory. In Extended Block mode the Boot Blocks are not accessible.
To exit from the Extended Block mode the Exit Extended Block command must be issued.
The Extended Block can be protected, however
once protected the protection cannot be undone.
Exit Extended Block Command
The Exit Extended Block command is used to exit
from the Extended Block mode and return the device to Read mode. Four Bus Write operations are
required to issue the command.
Block Protect and Chip Unprotect Commands
Groups of blocks can be protected against accidental Program or Erase. The whole chip can be
unprotected to allow the data inside the blocks to
be changed.
Block Protect and Chip Unprotect operations are
described in Appendix D.
13/42
M29W641DH, M29W641DL, M29W641DU
Command
Length
Table 3. Commands
Bus Write Operations
1st
2nd
Addr
Data
1
X
F0
3
555
Auto Select
3
Program
3rd
4th
Addr
Data
Addr
Data
AA
2AA
55
X
F0
555
AA
2AA
55
555
90
4
555
AA
2AA
55
555
A0
Double Word Program
3
555
50
PA0
PD0
PA1
PD1
Unlock Bypass
3
555
AA
2AA
55
555
20
Unlock Bypass
Program
2
X
A0
PA
PD
Unlock Bypass Reset
2
X
90
X
00
Chip Erase
6
555
AA
2AA
55
555
Block Erase
6+
555
AA
2AA
55
Erase Suspend
1
X
B0
Erase Resume
1
X
30
Read CFI Query
1
55
98
Enter Extended Block
3
555
AA
2AA
Exit Extended Block
4
555
AA
2AA
5th
Addr
Data
PA
PD
80
555
555
80
55
555
88
55
555
90
6th
Addr
Data
Addr
Data
AA
2AA
55
555
10
555
AA
2AA
55
BA
30
X
00
Read/Reset
Note: X Don’t Care, PA Program Address, PD Program Data, BA Any address in the Block. All values in the table are in hexadecimal.
Table 4. Program, Erase Times and Program, Erase Endurance Cycles
Typ (1, 2)
Max(2)
Unit
Chip Erase
80
400(3)
s
Block Erase (32 KWords)
0.8
6(4)
s
50(4)
µs
Parameter
Min
Erase Suspend Latency Time
Program (Word)
10
200(3)
µs
Double Word Program
10
200(3)
µs
Chip Program (Word by Word)
40
200(3)
s
Chip Program (Double Word)
20
100(3)
s
Program/Erase Cycles (per Block)
Data Retention
Note: 1.
2.
3.
4.
14/42
100,000
cycles
20
years
Typical values measured at room temperature and nominal voltages.
Sampled, but not 100% tested.
Maximum value measured at worst case conditions for both temperature and VCC after 100,00 program/erase cycles.
Maximum value measured at worst case conditions for both temperature and VCC.
M29W641DH, M29W641DL, M29W641DU
STATUS REGISTER
Bus Read operations from any address always
read the Status Register during Program and
Erase operations. It is also read during Erase Suspend when an address within a block being erased
is accessed.
The bits in the Status Register are summarized in
Table 5, Status Register Bits.
Data Polling Bit (DQ7). The Data Polling Bit can
be used to identify whether the Program/Erase
Controller has successfully completed its operation or if it has responded to an Erase Suspend.
The Data Polling Bit is output on DQ7 when the
Status Register is read.
During Program operations the Data Polling Bit
outputs the complement of the bit being programmed to DQ7. After successful completion of
the Program operation the memory returns to
Read mode and Bus Read operations from the address just programmed output DQ7, not its complement.
During Erase operations the Data Polling Bit outputs ’0’, the complement of the erased state of
DQ7. After successful completion of the Erase operation the memory returns to Read Mode.
In Erase Suspend mode the Data Polling Bit will
output a ’1’ during a Bus Read operation within a
block being erased. The Data Polling Bit will
change from a ’0’ to a ’1’ when the Program/Erase
Controller has suspended the Erase operation.
Figure 5, Data Polling Flowchart, gives an example of how to use the Data Polling Bit. A Valid Address is the address being programmed or an
address within the block being erased.
Toggle Bit (DQ6). The Toggle Bit can be used to
identify whether the Program/Erase Controller has
successfully completed its operation or if it has responded to an Erase Suspend. The Toggle Bit is
output on DQ6 when the Status Register is read.
During Program and Erase operations the Toggle
Bit changes from ’0’ to ’1’ to ’0’, etc., with successive Bus Read operations at any address. After
successful completion of the operation the memory returns to Read mode.
During Erase Suspend mode the Toggle Bit will
output when addressing a cell within a block being
erased. The Toggle Bit will stop toggling when the
Program/Erase Controller has suspended the
Erase operation.
Figure 6, Data Toggle Flowchart, gives an example of how to use the Data Toggle Bit.
Error Bit (DQ5). The Error Bit can be used to
identify errors detected by the Program/Erase
Controller. The Error Bit is set to ’1’ when a Program, Block Erase or Chip Erase operation fails to
write the correct data to the memory. If the Error
Bit is set a Read/Reset command must be issued
before other commands are issued. The Error bit
is output on DQ5 when the Status Register is read.
Note that the Program command cannot change a
bit set to ’0’ back to ’1’ and attempting to do so will
set DQ5 to ‘1’. A Bus Read operation to that address will show the bit is still ‘0’. One of the Erase
commands must be used to set all the bits in a
block or in the whole memory from ’0’ to ’1’.
Erase Timer Bit (DQ3). The Erase Timer Bit can
be used to identify the start of Program/Erase
Controller operation during a Block Erase command. Once the Program/Erase Controller starts
erasing the Erase Timer Bit is set to ’1’. Before the
Program/Erase Controller starts the Erase Timer
Bit is set to ’0’ and additional blocks to be erased
may be written to the Command Interface. The
Erase Timer Bit is output on DQ3 when the Status
Register is read.
Alternative Toggle Bit (DQ2). The Alternative
Toggle Bit can be used to monitor the Program/
Erase controller during Erase operations. The Alternative Toggle Bit is output on DQ2 when the
Status Register is read.
During Chip Erase and Block Erase operations the
Toggle Bit changes from ’0’ to ’1’ to ’0’, etc., with
successive Bus Read operations from addresses
within the blocks being erased. A protected block
is treated the same as a block not being erased.
Once the operation completes the memory returns
to Read mode.
During Erase Suspend the Alternative Toggle Bit
changes from ’0’ to ’1’ to ’0’, etc. with successive
Bus Read operations from addresses within the
blocks being erased. Bus Read operations to addresses within blocks not being erased will output
the memory cell data as if in Read mode.
After an Erase operation that causes the Error Bit
to be set the Alternative Toggle Bit can be used to
identify which block or blocks have caused the error. The Alternative Toggle Bit changes from ’0’ to
’1’ to ’0’, etc. with successive Bus Read Operations from addresses within blocks that have not
erased correctly. The Alternative Toggle Bit does
not change if the addressed block has erased correctly.
15/42
M29W641DH, M29W641DL, M29W641DU
Table 5. Status Register Bits
Address
DQ7
DQ6
DQ5
DQ3
DQ2
RB(1)
Program
Any Address
DQ7
Toggle
0
–
–
0
Program During Erase Suspend
Any Address
DQ7
Toggle
0
–
–
0
Program Error
Any Address
DQ7
Toggle
1
–
–
0
Chip Erase
Any Address
0
Toggle
0
1
Toggle
0
Erasing Block
0
Toggle
0
0
Toggle
0
Non-Erasing Block
0
Toggle
0
0
No
Toggle
0
Erasing Block
0
Toggle
0
1
Toggle
0
Non-Erasing Block
0
Toggle
0
1
No
Toggle
0
Erasing Block
1
No
Toggle
0
–
Toggle
1
Operation
Block Erase before timeout
Block Erase
Erase Suspend
Non-Erasing Block
Data read as normal
Good Block Address
0
Toggle
1
1
No
Toggle
0
Faulty Block Address
0
Toggle
1
1
Toggle
0
Erase Error
Note: 1. Only the M29W641DU device is concerned.
2. Unspecified data bits should be ignored.
16/42
1
M29W641DH, M29W641DL, M29W641DU
Figure 5. Data Polling Flowchart
Figure 6. Data Toggle Flowchart
START
START
READ DQ6
READ DQ5 & DQ7
at VALID ADDRESS
READ
DQ5 & DQ6
DQ7
=
DATA
YES
DQ6
=
TOGGLE
NO
NO
YES
NO
DQ5
=1
NO
YES
DQ5
=1
YES
READ DQ7
at VALID ADDRESS
READ DQ6
TWICE
DQ7
=
DATA
YES
DQ6
=
TOGGLE
NO
FAIL
PASS
NO
YES
FAIL
PASS
AI90194
AI90195B
17/42
M29W641DH, M29W641DL, M29W641DU
MAXIMUM RATING
Stressing the device above the rating listed in the
Absolute Maximum Ratings table may cause permanent damage to the device. Exposure to Absolute Maximum Rating conditions for extended
periods may affect device reliability. These are
stress ratings only and operation of the device at
these or any other conditions above those indicated in the Operating sections of this specification is
not implied. Refer also to the STMicroelectronics
SURE Program and other relevant quality documents.
Table 6. Absolute Maximum Ratings
Symbol
Parameter
Min
Max
Unit
TBIAS
Temperature Under Bias
–50
125
°C
TSTG
Storage Temperature
–65
150
°C
VCCQ
Input/Output Supply Voltage (1,2)
–0.6
4
V
VCC
Supply Voltage
–0.6
4
V
VID
Identification Voltage
–0.6
13.5
V
Program Voltage
–0.6
13.5
V
VPP(3)
Note: 1. Minimum voltage may undershoot to –2V during transition and for less than 20ns during transitions.
2. Maximum voltage may overshoot to V CC +2V during transition and for less than 20ns during transitions.
3. VPP must not remain at 12V for more than a total of 80hrs.
18/42
M29W641DH, M29W641DL, M29W641DU
DC AND AC PARAMETERS
This section summarizes the operating and measurement conditions, and the DC and AC characteristics of the device. The parameters in the DC
and AC Characteristic tables that follow are derived from tests performed under the Measure-
ment Conditions summarized in the relevant
tables. Designers should check that the operating
conditions in their circuit match the measurement
conditions when relying on the quoted parameters.
Table 7. Operating and AC Measurement Conditions
M29W641D
Parameter
70
90
100
120
Unit
Min
Max
Min
Max
Min
Max
Min
Max
VCC Supply Voltage
3.0
3.6
2.7
3.6
3.0
3.6
2.7
3.6
V
VCCQ Supply Voltage
3.0
3.6
2.7
3.6
1.65
1.95
1.65
1.95
V
Ambient Operating Temperature
–40
85
–40
85
–40
85
–40
85
°C
Load Capacitance (CL)
30
Input Rise and Fall Times
Input Pulse Voltages
Input and Output Timing Ref.
Voltages
30
30
30
pF
10
10
10
10
ns
0 to VCCQ
0 to VCCQ
0 to VCCQ
0 to VCCQ
V
VCCQ/2
VCCQ/2
VCCQ/2
VCCQ/2
V
Figure 7. AC Measurement I/O Waveform
Figure 8. AC Measurement Load Circuit
VPP
VCCQ
VCC
VCCQ
VCCQ
25kΩ
VCCQ/2
0V
DEVICE
UNDER
TEST
AI05557b
25kΩ
0.1µF
0.1µF
CL
0.1µF
CL includes JIG capacitance
AI05558b
Table 8. Device Capacitance
Symbol
CIN
COUT
Parameter
Input Capacitance
Output Capacitance
Test Condition
Min
Max
Unit
VIN = 0V
6
pF
VOUT = 0V
12
pF
Note: Sampled only, not 100% tested.
19/42
M29W641DH, M29W641DL, M29W641DU
Table 9. DC Characteristics
Symbol
Parameter
Test Condition
Min
Max
Unit
0V ≤ VIN ≤ VCCQ
±1
µA
0V ≤ VOUT ≤ VCCQ
±1
µA
ILI
Input Leakage Current
ILO
Output Leakage Current
ICC1
Supply Current (Read)
E = VIL, G = VIH,
f = 6 MHz
10
mA
ICC2
Supply Current (Standby)
E = VCC ±0.2V,
RP = VCC ±0.2V
100
µA
VPP pin =
VIL or VIH
20
mA
VPP pin =
VPPH
20
mA
ICC3
Supply Current (Program/
Erase)
Program/Erase
Controller active
VIL
Input Low Voltage
VCCQ ≤ VCC
–0.5
0.8
V
VIH
Input High Voltage
VCCQ ≤ VCC
0.7VCCQ
VCCQ + 0.3
V
11.5
12.5
V
VPPH
Voltage for VPP Program
Acceleration
VCC = 3.0V ±10%
IPP
Current for VPP Program
Acceleration
VCC = 3.0V ±10%
15
mA
VOL
Output Low Voltage
IOL = 4.0mA, VCC = VCCmin
0.45
V
VOH (1)
Output High Voltage
VID
Identification Voltage
11.5
12.5
V
Program/Erase Lockout Supply
Voltage
1.8
2.3
V
VLKO (1)
Note: 1. Sampled only, not 100% tested.
20/42
IOH = –2.0mA, VCC = VCCmin
0.85VCCQ
V
IOH = –100µA, VCC = VCCmin
VCCQ – 0.4
V
M29W641DH, M29W641DL, M29W641DU
Figure 9. Read Mode AC Waveforms
tAVAV
A0-A21
VALID
tAVQV
tAXQX
E
tELQV
tEHQX
tELQX
tEHQZ
G
tGLQX
tGHQX
tGLQV
tGHQZ
DQ0-DQ7/
DQ8-DQ15
VALID
AI06699
Table 10. Read AC Characteristics
M29W641D
Symbol
Alt
Parameter
Test Condition
Unit
70
90
100
120
tAVAV
tRC
Address Valid to Next Address Valid
E = VIL,
G = VIL
Min
70
90
100
120
ns
tAVQV
tACC
Address Valid to Output Valid
E = VIL,
G = VIL
Max
70
90
100
120
ns
tELQX (1)
tLZ
Chip Enable Low to Output Transition
G = VIL
Min
0
0
0
0
ns
tELQV
tCE
Chip Enable Low to Output Valid
G = VIL
Max
70
90
100
120
ns
tGLQX (1)
tOLZ
Output Enable Low to Output Transition
E = VIL
Min
0
0
0
0
ns
tGLQV
tOE
Output Enable Low to Output Valid
E = VIL
Max
30
35
35
50
ns
tEHQZ (1)
tHZ
Chip Enable High to Output Hi-Z
G = VIL
Max
25
30
30
30
ns
tGHQZ (1)
tDF
Output Enable High to Output Hi-Z
E = VIL
Max
25
30
30
30
ns
tEHQX
tGHQX
tAXQX
tOH
Chip Enable, Output Enable or Address
Transition to Output Transition
Min
0
0
0
0
ns
Note: 1. Sampled only, not 100% tested.
21/42
M29W641DH, M29W641DL, M29W641DU
Figure 10. Write AC Waveforms, Write Enable Controlled
tAVAV
A0-A21
VALID
tWLAX
tAVWL
tWHEH
E
tELWL
tWHGL
G
tGHWL
tWLWH
W
tWHWL
tDVWH
DQ0-DQ7/
DQ8-DQ15
tWHDX
VALID
VCC
tVCHEL
RB
tWHRL
AI06800b
Note: 1. RB concerns the M29W461DU only.
Table 11. Write AC Characteristics, Write Enable Controlled
M29W641D
Symbol
Alt
Parameter
Unit
70
90
100
120
tAVAV
tWC
Address Valid to Next Address Valid
Min
70
90
100
120
ns
tELWL
tCS
Chip Enable Low to Write Enable Low
Min
0
0
0
0
ns
tWLWH
tWP
Write Enable Low to Write Enable High
Min
35
35
35
50
ns
tDVWH
tDS
Input Valid to Write Enable High
Min
45
45
45
50
ns
tWHDX
tDH
Write Enable High to Input Transition
Min
0
0
0
0
ns
tWHEH
tCH
Write Enable High to Chip Enable High
Min
0
0
0
0
ns
tWHWL
tWPH
Write Enable High to Write Enable Low
Min
30
30
30
30
ns
tAVWL
tAS
Address Valid to Write Enable Low
Min
0
0
0
0
ns
tWLAX
tAH
Write Enable Low to Address Transition
Min
45
45
45
50
ns
Output Enable High to Write Enable Low
Min
0
0
0
0
ns
tGHWL
tWHGL
tOEH
Write Enable High to Output Enable Low
Min
0
0
0
0
ns
tWHRL(1)
tBUSY
Program/Erase Valid to RB Low
Max
90
90
90
90
ns
tVCHEL
tVCS
VCC High to Chip Enable Low
Min
50
50
50
50
µs
Note: 1. This timing concerns the M29W461DU only.
22/42
M29W641DH, M29W641DL, M29W641DU
Figure 11. Write AC Waveforms, Chip Enable Controlled
tAVAV
A0-A21
VALID
tELAX
tAVEL
tEHWH
W
tWLEL
tEHGL
G
tGHEL
tELEH
E
tEHEL
tDVEH
DQ0-DQ7/
DQ8-DQ15
tEHDX
VALID
VCC
tVCHWL
RB
tEHRL
AI06801b
Note: 1. RB concerns the M29W461DU only.
Table 12. Write AC Characteristics, Chip Enable Controlled
M29W641D
Symbol
Alt
Parameter
Unit
70
90
100
120
tAVAV
tWC
Address Valid to Next Address Valid
Min
70
90
100
120
ns
tWLEL
tWS
Write Enable Low to Chip Enable Low
Min
0
0
0
0
ns
tELEH
tCP
Chip Enable Low to Chip Enable High
Min
45
45
45
50
ns
tDVEH
tDS
Input Valid to Chip Enable High
Min
45
45
45
50
ns
tEHDX
tDH
Chip Enable High to Input Transition
Min
0
0
0
0
ns
tEHWH
tWH
Chip Enable High to Write Enable High
Min
0
0
0
0
ns
tEHEL
tCPH
Chip Enable High to Chip Enable Low
Min
30
30
30
30
ns
tAVEL
tAS
Address Valid to Chip Enable Low
Min
0
0
0
0
ns
tELAX
tAH
Chip Enable Low to Address Transition
Min
45
45
45
50
ns
Output Enable High Chip Enable Low
Min
0
0
0
0
ns
tGHEL
tEHGL
tOEH
Chip Enable High to Output Enable Low
Min
0
0
0
0
ns
tEHRL (1)
tBUSY
Program/Erase Valid to RB Low
Max
90
90
90
90
ns
tVCHWL
tVCS
VCC High to Write Enable Low
Min
50
50
50
50
µs
Note: 1. This timing concerns the M29W461DU only.
23/42
M29W641DH, M29W641DL, M29W641DU
Figure 12. Reset/Block Temporary Unprotect AC Waveforms
W, E, G
tPHWL, tPHEL, tPHGL
RB
tRHWL, tRHEL, tRHGL
tPLPX
RP
tPHPHH
tPLYH
AI06802b
Note: 1. RB concerns the M29W461DU only.
Table 13. Reset/Block Temporary Unprotect AC Characteristics
M29W641D
Symbol
Alt
tPHWL (1)
tPHEL
tPHGL
100
120
Min
50
50
50
50
ns
tRB
RB High to Write Enable Low, Chip Enable Low,
Output Enable Low
Min
0
0
0
0
ns
Max
50
50
50
50
µs
RP Pulse Width
Min
500
500
500
500
ns
RP Rise Time to VID
Min
500
500
500
500
ns
VPP Rise and Fall Time
Min
250
250
250
250
ns
tREADY RP Low to Read Mode
tPLPX
tRP
tPHPHH (1)
tVIDR
tVHVPP (1)
90
RP High to Write Enable Low, Chip Enable Low,
Output Enable Low
tRHGL (1, 2)
tPLYH
Unit
70
tRH
(1)
tRHWL (1, 2)
tRHEL (1, 2)
Parameter
Note: 1. Sampled only, not 100% tested.
2. These timings concern the M29W461DU only.
Figure 13. Accelerated Program Timing Waveforms
VPP
VPP Pin
VIL or VIH
tVHVPP
tVHVPP
AI06806
24/42
M29W641DH, M29W641DL, M29W641DU
PACKAGE MECHANICAL
Figure 14. TSOP48 – 48 lead Plastic Thin Small Outline, 12 x 20mm, Package Outline
A2
1
N
e
E
B
N/2
D1
A
CP
D
DIE
C
A1
TSOP-a
α
L
Note: Drawing is not to scale.
Table 14. TSOP48 – 48 lead Plastic Thin Small Outline, 12 x 20mm, Package Mechanical Data
millimeters
inches
Symbol
Typ
Min
A
Max
Typ
Min
1.200
Max
0.0472
A1
0.100
0.050
0.150
0.0039
0.0020
0.0059
A2
1.000
0.950
1.050
0.0394
0.0374
0.0413
B
0.170
0.270
0.0067
0.0106
C
0.100
0.210
0.0039
0.0083
CP
0.100
0.0039
D
19.800
20.200
0.7795
0.7953
D1
18.300
18.500
0.7205
0.7283
–
–
–
–
E
11.900
12.100
0.4685
0.4764
L
0.500
0.700
0.0197
0.0276
alfa
0
5
0
5
e
N
0.500
48
0.0197
48
25/42
M29W641DH, M29W641DL, M29W641DU
Figure 15. TFBGA63 - 7x11mm, 6x8 active ball array, 0.8mm pitch, Bottom view package outline
D
D1
SD
FD
e
E
ddd
SE
E1
BALL "A1"
FE
A
e
b
A2
A1
BGA-Z33
Note: Drawing is not to scale.
Table 15. TFBGA63 - 7x11mm, 6x8 active ball array, 0.8mm pitch, Package Mechanical Data
millimeters
inches
Symbol
Typ
Min
A
Max
Typ
Min
1.200
A1
0.0472
0.250
A2
0.0098
0.900
b
Max
0.350
0.450
0.0354
0.0138
0.0177
D
7.000
6.900
7.100
0.2756
0.2717
0.2795
D1
5.600
–
–
0.2205
–
–
ddd
–
–
0.100
–
–
0.0039
E
11.000
10.900
11.100
0.4331
0.4291
0.4370
E1
8.800
–
–
0.3465
–
–
e
0.800
–
–
0.0315
–
–
FD
0.700
–
–
0.0276
–
–
FE
1.100
–
–
0.0433
–
–
SD
0.400
–
–
0.0157
–
–
SE
0.400
–
–
0.0157
–
–
26/42
M29W641DH, M29W641DL, M29W641DU
PART NUMBERING
Table 16. Ordering Information Scheme
Example:
M29W641DL
70
N
1
T
Device Type
M29
Operating Voltage
W = VCC = 2.7 to 3.6V
Device Function
641DH = 64 Mbit (x16), Uniform Block, Write Protection on highest
address Block
641DL = 64 Mbit (x16), Uniform Block, Write Protection on Lowest
Address Block
641DU = 64 Mbit (x16), Uniform Block, No Write Protection
Speed
70 = 70ns
90 = 90ns
10 = 100ns
12 = 120ns
Package
N = TSOP48: 12 x 20 mm (M29W641DH and M29W641DL only)
ZA = TFBGA63: 7 x 11mm, 0.80mm pitch (M29W641DU only)
Temperature Range
1 = 0 to 70 °C
6 = –40 to 85 °C
Option
T = Tape & Reel Packing
E = Lead-free Package, Standard Packing
F = Lead-free Package, Tape & Reel Packing
Note: This product is also available with the Extended Block factory locked. For further details and ordering
information contact your nearest ST sales office.
Devices are shipped from the factory with the memory content bits erased to 1. For a list of available options (Speed, Package, etc.) or for further information on any aspect of this device, please contact your
nearest ST Sales Office.
27/42
M29W641DH, M29W641DL, M29W641DU
APPENDIX A. BLOCK ADDRESSES
Table 17. Block Addresses
Block
KWords
Protection Block Group
Address Range
0
32
1
32
2
32
010000h–017FFFh
3
32
018000h–01FFFFh
4
32
020000h–027FFFh
5
32
000000h–007FFFh (1)
Protection Group
008000h–00FFFFh
028000h–02FFFFh
Protection Group
6
32
030000h–037FFFh
7
32
038000h–03FFFFh
8
32
040000h–047FFFh
9
32
048000h–04FFFFh
Protection Group
10
32
050000h–057FFFh
11
32
058000h–05FFFFh
12
32
060000h–067FFFh
13
32
068000h–06FFFFh
Protection Group
14
32
070000h–077FFFh
15
32
078000h–07FFFFh
16
32
080000h–087FFFh
17
32
088000h–08FFFFh
Protection Group
18
32
090000h–097FFFh
19
32
098000h–09FFFFh
20
32
0A0000h–0A7FFFh
21
32
0A8000h–0AFFFFh
Protection Group
22
32
0B0000h–0B7FFFh
23
32
0B8000h–0BFFFFh
24
32
0C0000h–0C7FFFh
25
32
0C8000h–0CFFFFh
Protection Group
26
32
0D0000h–0D7FFFh
27
32
0D8000h–0DFFFFh
28
32
0E0000h–0E7FFFh
29
32
0E8000h–0EFFFFh
Protection Group
28/42
30
32
0F0000h–0F7FFFh
31
32
0F8000h–0FFFFFh
M29W641DH, M29W641DL, M29W641DU
Block
KWords
32
32
33
32
Protection Block Group
Address Range
100000h–107FFFh
108000h–10FFFFh
Protection Group
34
32
110000h–117FFFh
35
32
118000h–11FFFFh
36
32
120000h–127FFFh
37
32
128000h–12FFFFh
Protection Group
38
32
130000h–137FFFh
39
32
138000h–13FFFFh
40
32
140000h–147FFFh
41
32
148000h–14FFFFh
Protection Group
42
32
150000h–157FFFh
43
32
158000h–15FFFFh
44
32
160000h–167FFFh
45
32
168000h–16FFFFh
Protection Group
46
32
170000h–177FFFh
47
32
178000h–17FFFFh
48
32
180000h–187FFFh
49
32
188000h–18FFFFh
Protection Group
50
32
190000h–197FFFh
51
32
198000h–19FFFFh
52
32
1A0000h–1A7FFFh
53
32
1A8000h–1AFFFFh
Protection Group
54
32
1B0000h–1B7FFFh
55
32
1B8000h–1BFFFFh
56
32
1C0000h–1C7FFFh
57
32
1C8000h–1CFFFFh
Protection Group
58
32
1D0000h–1D7FFFh
59
32
1D8000h–1DFFFFh
60
32
1E0000h–1E7FFFh
61
32
1E8000h–1EFFFFh
Protection Group
62
32
1F0000h–1F7FFFh
63
32
1F8000h–1FFFFFh
64
32
200000h–207FFFh
65
32
208000h–20FFFFh
Protection Group
66
32
210000h–217FFFh
67
32
218000h–21FFFFh
29/42
M29W641DH, M29W641DL, M29W641DU
Block
KWords
68
32
69
32
Protection Block Group
Address Range
220000h–227FFFh
228000h–22FFFFh
Protection Group
70
32
230000h–237FFFh
71
32
238000h–23FFFFh
72
32
240000h–247FFFh
73
32
248000h–24FFFFh
Protection Group
74
32
250000h–257FFFh
75
32
258000h–25FFFFh
76
32
260000h–267FFFh
77
32
268000h–26FFFFh
Protection Group
78
32
270000h–277FFFh
79
32
278000h–27FFFFh
80
32
280000h–287FFFh
81
32
288000h–28FFFFh
Protection Group
82
32
290000h–297FFFh
83
32
298000h–29FFFFh
84
32
2A0000h–2A7FFFh
85
32
2A8000h–2AFFFFh
Protection Group
86
32
2B0000h–2B7FFFh
87
32
2B8000h–2BFFFFh
88
32
2C0000h–2C7FFFh
89
32
2C8000h–2CFFFFh
Protection Group
90
32
2D0000h–2D7FFFh
91
32
2D8000h–2DFFFFh
92
32
2E0000h–2E7FFFh
93
32
2E8000h–2EFFFFh
Protection Group
94
32
2F0000h–2F7FFFh
95
32
2F8000h–2FFFFFh
96
32
300000h–307FFFh
97
32
308000h–30FFFFh
Protection Group
98
32
310000h–317FFFh
99
32
318000h–31FFFFh
100
32
320000h–327FFFh
101
32
328000h–32FFFFh
Protection Group
30/42
102
32
330000h–337FFFh
103
32
338000h–33FFFFh
M29W641DH, M29W641DL, M29W641DU
Block
KWords
104
32
105
32
Protection Block Group
Address Range
340000h–347FFFh
348000h–34FFFFh
Protection Group
106
32
350000h–357FFFh
107
32
358000h–35FFFFh
108
32
360000h–367FFFh
109
32
368000h–36FFFFh
Protection Group
110
32
370000h–377FFFh
111
32
378000h–37FFFFh
112
32
380000h–387FFFh
113
32
388000h–38FFFFh
Protection Group
114
32
390000h–397FFFh
115
32
398000h–39FFFFh
116
32
3A0000h–3A7FFFh
117
32
3A8000h–3AFFFFh
Protection Group
118
32
3B0000h–3B7FFFh
119
32
3B8000h–3BFFFFh
120
32
3C0000h–3C7FFFh
121
32
3C8000h–3CFFFFh
Protection Group
122
32
3D0000h–3D7FFFh
123
32
3D8000h–3DFFFFh
124
32
3E0000h–3E7FFFh
125
32
126
32
127
32
3E8000h–3EFFFFh
Protection Group
3F0000h–3F7FFFh
3F8000h–3FFFFFh
Note: 1. Used as the Extended Block Addresses in Extended Block mode.
31/42
M29W641DH, M29W641DL, M29W641DU
APPENDIX B. COMMON FLASH INTERFACE (CFI)
The Common Flash Interface is a JEDEC approved, standardized data structure that can be
read from the Flash memory device. It allows a
system software to query the device to determine
various electrical and timing parameters, density
information and functions supported by the memory. The system can interface easily with the device, enabling the software to upgrade itself when
necessary.
When the CFI Query Command is issued the device enters CFI Query mode and the data structure
is read from the memory. Table 18 to Table 23
show the addresses used to retrieve the data.
The CFI data structure also contains a security
area where a 64 bit unique security number is written (see Table 23, Security Code Area). This area
can be accessed only in Read mode by the final
user. It is impossible to change the security number after it has been written by ST.
Table 18. Query Structure Overview
Address
Sub-section Name
Description
10h
CFI Query Identification String
Command set ID and algorithm data offset
1Bh
System Interface Information
Device timing & voltage information
27h
Device Geometry Definition
Flash device layout
40h
Primary Algorithm-specific Extended
Query table
Additional information specific to the Primary
Algorithm (optional)
61h
Security Code Area
64 bit unique device number
Note: Query data are always presented on the lowest order data outputs.
Table 19. CFI Query Identification String
Address
Data
Description
10h
0051h
11h
0052h
12h
0059h
13h
0002h
14h
0000h
15h
0040h
16h
0000h
17h
0000h
18h
0000h
Alternate Vendor Command Set and Control Interface ID Code second
vendor - specified algorithm supported
19h
0000h
Address for Alternate Algorithm extended Query table
1Ah
0000h
“Q”
Query Unique ASCII String "QRY"
"R"
"Y"
Primary Algorithm Command Set and Control Interface ID code 16 bit
ID code defining a specific algorithm
Address for Primary Algorithm extended Query table (see Table 22)
Note: Query data are always presented on the lowest order data outputs (DQ7-DQ0) only. DQ8-DQ15 are ‘0’.
32/42
Value
AMD
Compatible
P = 40h
NA
NA
M29W641DH, M29W641DL, M29W641DU
Table 20. CFI Query System Interface Information
Address
Data
Description
Value
1Bh
0027h
VCC Logic Supply Minimum Program/Erase voltage
bit 7 to 4
BCD value in volts
bit 3 to 0
BCD value in 100 mV
2.7V
1Ch
0036h
VCC Logic Supply Maximum Program/Erase voltage
bit 7 to 4
BCD value in volts
bit 3 to 0
BCD value in 100 mV
3.6V
1Dh
00B5h
VPP [Programming] Supply Minimum Program/Erase voltage
bit 7 to 4
HEX value in volts
bit 3 to 0
BCD value in 100 mV
11.5V
1Eh
00C5h
VPP [Programming] Supply Maximum Program/Erase voltage
bit 7 to 4
HEX value in volts
bit 3 to 0
BCD value in 100 mV
12.5V
1Fh
0004h
Typical timeout per single word program = 2n µs
16µs
20h
0000h
Typical timeout for minimum size write buffer program = 2n µs
NA
21h
000Ah
Typical timeout per individual block erase = 2n ms
1s
22h
0000h
Typical timeout for full chip erase = 2n ms
NA
23h
0004h
Maximum timeout for word program = 2n times typical
24h
0000h
Maximum timeout for write buffer program = 2n times typical
NA
25h
0003h
Maximum timeout per individual block erase = 2n times typical
8s
26h
0000h
Maximum timeout for chip erase = 2n times typical
NA
256 µs
Table 21. Device Geometry Definition
Address
Data
Description
Value
27h
0017h
Device Size = 2n in number of bytes
28h
29h
0001h
0000h
Flash Device Interface Code description
2Ah
2Bh
0000h
0000h
Maximum number of bytes in multi-byte program or page = 2n
NA
2Ch
0001h
Number of Erase Block Regions. It specifies the number of
regions containing contiguous Erase Blocks of the same size.
1
2Dh
2Eh
007Fh
0000h
Region 1 Information
Number of identical size erase block = 007Fh+1
2Fh
30h
0000h
0001h
Region 1 Information
Block size in Region 1 = 0100h * 256 byte
8 MByte
x16
Async.
128
64 KByte
33/42
M29W641DH, M29W641DL, M29W641DU
Table 22. Primary Algorithm-Specific Extended Query Table
Address
Data
Description
40h
0050h
41h
0052h
42h
0049h
43h
0031h
Major version number, ASCII
"1"
44h
0030h
Minor version number, ASCII
"0"
45h
0000h
Address Sensitive Unlock (bits 1 to 0)
00 = required, 01= not required
Silicon Revision Number (bits 7 to 2)
Yes
46h
0002h
Erase Suspend
00 = not supported, 01 = Read only, 02 = Read and Write
2
47h
0004h
Block Protection
00 = not supported, x = number of blocks per protection group
4
48h
0001h
Temporary Block Unprotect
00 = not supported, 01 = supported
49h
0004h
Block Protect /Unprotect
04 = M29W400B
4Ah
0000h
Simultaneous Operations, 00 = not supported
No
4Bh
0000h
Burst Mode, 00 = not supported, 01 = supported
No
4Ch
0000h
Page Mode, 00 = not supported, 01 = 4 page word, 02 = 8 page word
No
4Dh
00B5h
VPP Supply Minimum Program/Erase voltage
bit 7 to 4 HEX value in volts
bit 3 to 0 BCD value in 100 mV
11.5V
4Eh
00C5h
VPP Supply Maximum Program/Erase voltage
bit 7 to 4 HEX value in volts
bit 3 to 0 BCD value in 100 mV
12.5V
"P"
Primary Algorithm extended Query table unique ASCII string “PRI”
34/42
Data
61h
XXXX
62h
XXXX
63h
XXXX
64h
XXXX
"R"
"I"
Description
64 bit: unique device number
Yes
4
Table 23. Security Code Area
Address
Value
M29W641DH, M29W641DL, M29W641DU
APPENDIX C. EXTENDED MEMORY BLOCK
The M29W641D has an extra block, the Extended
Block, that can be accessed using a dedicated
command.
This Extended Block is 32 KWords. It is used as a
security block (to provide a permanent security
identification number) or to store additional information.
The Extended Block is either Factory Locked or
Customer Lockable, its status is indicated by bit
DQ7. This bit is permanently set to either ‘1’ or ‘0’
at the factory and cannot be changed. When set to
‘1’, it indicates that the device is factory locked and
the Extended Block is protected. When set to ‘0’, it
indicates that the device is customer lockable and
the Extended Block is unprotected. Bit DQ7 being
permanently locked to either ‘1’ or ‘0’ is another
security feature which ensures that a customer
lockable device cannot be used instead of a factory locked one.
Bit DQ7 is the most significant bit in the Extended
Block Verify Code and a specific procedure must
be followed to read it. See “Extended Memory
Block Verify Code” in Table 2, Bus Operations, for
details of how to read bit DQ7.
The Extended Block can only be accessed when
the device is in Extended Block mode. For details
of how the Extended Block mode is entered and
exited, refer to the Enter Extended Block Command and Exit Extended Block Command paragraphs, and to Table 3, “Commands”.
Factory Locked Extended Block
In devices where the Extended Block is factory
locked, the Security Identification Number is written to the Extended Block address space (see Table 24, Extended Block Address and Data) in the
factory. The DQ7 bit is set to ‘1’ and the Extended
Block cannot be unprotected.
Customer Lockable Extended Block
A device where the Extended Block is customer
lockable is delivered with the DQ7 bit set to ‘0’ and
the Extended Block unprotected. It is up to the
customer to program and protect the Extended
Block but care must be taken because the protection of the Extended Block is not reversible.
There are two ways of protecting the Extended
Block:
■ Issue the Enter Extended Block command to
place the device in Extended Block mode, then
use the In-System Technique (refer to Appendix
D, In-System Technique and to the
corresponding flowcharts, Figures 18 and 19,
for a detailed explanation of the technique).
■ Issue the Enter Extended Block command to
place the device in Extended Block mode, then
use the Programmer Technique (refer to
Appendix D, Programmer Technique and to the
corresponding flowcharts, Figures 16 and 17,
for a detailed explanation of the technique).
Once the Extended Block is programmed and protected, the Exit Extended Block command must be
issued to exit the Extended Block mode and return
the device to Read mode.
Table 24. Extended Block Address and Data
Device
Address(1)
Data
x16
Factory Locked
000000h-000007h
Security Identification Number
000008h-007FFFh
Unavailable
M29W641D
Customer Lockable
Determined by Customer
Note: 1. See Table 17, Block Addresses.
35/42
M29W641DH, M29W641DL, M29W641DU
APPENDIX D. BLOCK PROTECTION
Block protection can be used to prevent any operation from modifying the data stored in the memory. Once protected, Program and Erase
operations within the protected group fail to
change the data.
There are three techniques that can be used to
control Block Protection, these are the Programmer technique, the In-System technique and Temporary Unprotection. Temporary Unprotection is
controlled by the Reset/Block Temporary Unprotection pin, RP; this is described in the Signal Descriptions section.
Programmer Technique
The Programmer technique uses high (V ID) voltage levels on some of the bus pins. These cannot
be achieved using a standard microprocessor bus,
therefore the technique is recommended only for
use in Programming Equipment.
To protect a group of blocks follow the flowchart in
Figure 16, Programmer Equipment Group Protect
Flowchart. To unprotect the whole chip it is necessary to protect all of the groups first, then all
groups can be unprotected at the same time. To
unprotect the chip follow Figure 17, Programmer
Equipment Chip Unprotect Flowchart. Table 25,
Programmer Technique Bus Operations, gives a
summary of each operation.
The timing on these flowcharts is critical. Care
should be taken to ensure that, where a pause is
specified, it is followed as closely as possible. Do
not abort the procedure before reaching the end.
Chip Unprotect can take several seconds and a
user message should be provided to show that the
operation is progressing.
In-System Technique
The In-System technique requires a high voltage
level on the Reset/Blocks Temporary Unprotect
pin, RP. This can be achieved without violating the
maximum ratings of the components on the microprocessor bus, therefore this technique is suitable
for use after the memory has been fitted to the system.
To protect a group of blocks follow the flowchart in
Figure 18, In-System Equipment Group Protect
Flowchart. To unprotect the whole chip it is necessary to protect all of the groups first, then all the
groups can be unprotected at the same time. To
unprotect the chip follow Figure 19, In-System
Equipment Chip Unprotect Flowchart.
The timing on these flowcharts is critical. Care
should be taken to ensure that, where a pause is
specified, it is followed as closely as possible. Do
not allow the microprocessor to service interrupts
that will upset the timing and do not abort the procedure before reaching the end. Chip Unprotect
can take several seconds and a user message
should be provided to show that the operation is
progressing.
Table 25. Programmer Technique Bus Operations
E
G
W
Address Inputs
A0-A21
Data Inputs/Outputs
DQ15-DQ0
Block (Group)
Protect(1)
VIL
VID
VIL Pulse
A9 = VID, A12-A21 Block Address
Others = X
X
Chip Unprotect
VID
VID
VIL Pulse
A9 = VID, A12 = VIH, A15 = VIH
Others = X
X
Block (Group)
Protection Verify
VIL
VIL
VIH
A0 = VIL, A1 = VIH, A6 = VIL, A9 = VID,
A12-A21 Block Address
Others = X
Pass = XX01h
Retry = XX00h
Block (Group)
Unprotection Verify
VIL
VIL
VIH
A0 = VIL, A1 = VIH, A6 = VIH, A9 = VID,
A12-A21 Block Address
Others = X
Retry = XX01h
Pass = XX00h
Operation
Note: 1. Block Protection Groups are shown in Appendix A, Tables 17.
36/42
M29W641DH, M29W641DL, M29W641DU
Figure 16. Programmer Equipment Group Protect Flowchart
START
Set-up
ADDRESS = GROUP ADDRESS
W = VIH
n=0
G, A9 = VID,
E = VIL
Protect
Wait 4µs
W = VIL
Wait 100µs
W = VIH
E, G = VIH,
A0, A6 = VIL,
A1 = VIH
E = VIL
Verify
Wait 4µs
G = VIL
Wait 60ns
Read DATA
DATA
NO
=
01h
YES
A9 = VIH
E, G = VIH
++n
= 25
NO
End
YES
PASS
A9 = VIH
E, G = VIH
FAIL
AI05574
37/42
M29W641DH, M29W641DL, M29W641DU
Figure 17. Programmer Equipment Chip Unprotect Flowchart
START
Set-up
PROTECT ALL GROUPS
n=0
CURRENT GROUP = 0
A6, A12, A15 = VIH(1)
E, G, A9 = VID
Unprotect
Wait 4µs
W = VIL
Wait 10ms
W = VIH
E, G = VIH
ADDRESS = CURRENT GROUP ADDRESS
A0 = VIL, A1, A6 = VIH
E = VIL
Wait 4µs
G = VIL
INCREMENT
CURRENT GROUP
Verify
Wait 60ns
Read DATA
NO
End
NO
38/42
++n
= 1000
DATA
=
00h
YES
LAST
GROUP
YES
YES
A9 = VIH
E, G = VIH
A9 = VIH
E, G = VIH
FAIL
PASS
NO
AI05575
M29W641DH, M29W641DL, M29W641DU
Figure 18. In-System Equipment Group Protect Flowchart
Set-up
START
n=0
RP = VID
Protect
WRITE 60h
ADDRESS = GROUP ADDRESS
A0 = VIL, A1 = VIH, A6 = VIL
WRITE 60h
ADDRESS = GROUP ADDRESS
A0 = VIL, A1 = VIH, A6 = VIL
Wait 100µs
Verify
WRITE 40h
ADDRESS = GROUP ADDRESS
A0 = VIL, A1 = VIH, A6 = VIL
Wait 4µs
READ DATA
ADDRESS = GROUP ADDRESS
A0 = VIL, A1 = VIH, A6 = VIL
DATA
NO
=
01h
YES
End
RP = VIH
ISSUE READ/RESET
COMMAND
PASS
++n
= 25
NO
YES
RP = VIH
ISSUE READ/RESET
COMMAND
FAIL
AI05576
39/42
M29W641DH, M29W641DL, M29W641DU
Figure 19. In-System Equipment Chip Unprotect Flowchart
START
Set-up
PROTECT ALL GROUPS
n=0
CURRENT GROUP = 0
RP = VID
WRITE 60h
ANY ADDRESS WITH
A0 = VIL, A1 = VIH, A6 = VIH
Unprotect
WRITE 60h
ANY ADDRESS WITH
A0 = VIL, A1 = VIH, A6 = VIH
Wait 10ms
Verify
WRITE 40h
ADDRESS = CURRENT GROUP ADDRESS
A0 = VIL, A1 = VIH, A6 = VIH
Wait 4µs
READ DATA
ADDRESS = CURRENT GROUP ADDRESS
A0 = VIL, A1 = VIH, A6 = VIH
NO
End
NO
++n
= 1000
YES
DATA
=
00h
INCREMENT
CURRENT GROUP
YES
LAST
GROUP
NO
YES
RP = VIH
RP = VIH
ISSUE READ/RESET
COMMAND
ISSUE READ/RESET
COMMAND
FAIL
PASS
AI05577
40/42
M29W641DH, M29W641DL, M29W641DU
REVISION HISTORY
Table 26. Document Revision History
Date
Version
30-Apr-2002
-01
Document released
1.1
When in Extended Block mode, the block at the boot block address can be used as OTP.
Data Toggle Flow chart corrected. Double Word Program Time (typ) changed to 20s.
Revision numbering modified: a minor revision will be indicated by incrementing the digit
after the dot, and a major revision, by incrementing the digit before the dot (revision
version 01 equals 1.0).
2.0
New Part Numbers added. 100ns and 120ns Speed Classes added. TFBGA63 package
added. VIO removed from and VCCQ added to Table 6, Absolute Maximum Ratings. VCCQ
added to Table 7, Operating and AC Measurement Conditions. Ready/Busy pin
(TFBGA63 package) added to the signals (concerns M29W641DU only).
Figure 7, AC Measurement I/O Waveform, and Figure 8, AC Measurement Load Circuit,
modified. Unlock Bypass Commands clarified and VCCQ description specified in SIGNAL
DESCRIPTIONS section. Test Conditions modified for ILI, ILO, VIL, VIH, VOL and VOH
parameters in Table 9, DC Characteristics, and VIL, VIH, VOL and VOH parameters
corrected. tWLWH, tDVWH, tWLAX, tWHRL parameters modified for 90ns speed class in Table
11, Write AC Characteristics, Write Enable Controlled. tELEH, tDVEH, tELAX and tEHRL
parameters modified for 90ns speed class in Table 12, Write AC Characteristics, Chip
Enable Controlled. tPLYH parameter added to Table 13, Reset/Block Temporary Unprotect
AC Characteristics.
Data and Value modified for address 2Dh, and Data modified for address 30h in Table 21,
Device Geometry Definition. Description modified at address offset 4Eh in Table 22.
Data Retention and Erase Suspend Latency Time parameters added to Table 6, Program,
Erase Times and Program, Erase Endurance Cycles, and Typical after 100k W/E Cycles
column removed. IID (Identification) current removed from Table 9, DC Characteristics.
Lead-free package options E and F added to Table 16, Ordering Information Scheme.
Appendix C, EXTENDED MEMORY BLOCK, added. VSS pin connection to ground
clarified. Auto Select Command is used to read the Extended Memory Block. Note added
to Table 16, Ordering Information Scheme.
05-Sep-2002
8-Apr-2003
Revision Details
41/42
M29W641DH, M29W641DL, M29W641DU
Information furnished is believed to be accurate and reliable. However, STMicroelectronics assumes no responsibility for the consequences
of use of such information nor for any infringement of patents or other rights of third parties which may result from its use. No license is granted
by implication or otherwise under any patent or patent rights of STMicroelectronics. Specifications mentioned in this publication are subject
to change without notice. This publication supersedes and replaces all information previously supplied. STMicroelectronics products are not
authorized for use as critical components in life support devices or systems without express written approval of STMicroelectronics.
The ST logo is registered trademark of STMicroelectronics
All other names are the property of their respective owners
© 2003 STMicroelectronics - All Rights Reserved
STMicroelectronics group of companies
Australia - Brazil - Canada - China - Finland - France - Germany - Hong Kong India - Israel - Italy - Japan - Malaysia - Malta - Morocco - Singapore - Spain - Sweden - Switzerland - United Kingdom - United States.
www.st.com
42/42
Similar pages