Astrodyne LPP150-24 150w single output with pfc function Datasheet

LPP150
150W S i n g l e Ou t put w it h P FC Func t i on
series
Universal AC input
Protections:Short circuit/Over load/Over voltage
Protections: Over temperature (option)
Built-in active PFC function, PF> 0.96
Cooling by free air convection
Fixed switching frequency at PFC:67KHz PWM:134KHz
Model Number
Output Volts
Output Amps
3.3 Volts(DC)
5 Volts(DC)
7.5 Volts(DC)
12 Volts(DC)
13.5 Volts(DC)
15 Volts(DC)
24 Volts(DC)
27 Volts(DC)
48 Volts(DC)
30 Amps
30 Amps
20 Amps
12.5 Amps
11.2 Amps
10 Amps
6.3 Amps
5.6 Amps
3.2 Amps
Ripple & Noise
Min Load
DC Volt Adjust Load Reg Efficiency
SINGLE OUTPUT
LPP150-3.3
LPP150-5
LPP150-7.5
LPP150-12
LPP150-13.5
LPP150-15
LPP150-24
LPP150-27
LPP150-48
WWW.ASTRODYNETDI.COM
100mV pk-pk
100mV pk-pk
100mV pk-pk
100mV pk-pk
100mV pk-pk
100mV pk-pk
150mV pk-pk
150mV pk-pk
250mV pk-pk
0~30Amps
0~30Amps
0~20Amps
0~12.5Amps
0~11.2Amps
0~10Amps
0~6.3Amps
0~5..6Amps
0~3.2Amps
3.14~3.63Volt(DC)
4.75~5.5Volt(DC)
7.13~8.25Volt(DC)
11.4~13.2Volt(DC
12.8~14.9Volt(DC)
14.3~16.5Volt(DC)
22.8~26.4Volt(DC)
25.7~29.7Volt(DC)
45.6~52.8Volt(DC)
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±0.5%
±0.5%
±0.5%
66%
72%
76%
79%
80%
80%
83%
83%
83%
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
LPP150
150W S i n g l e Ou t put w it h P FC Func t i on
INPUT SPECIFICATIONS
Input Voltage Range (Note 3)
Frequency Range
Inrush Current, typ: (cold start)
Input Current
Leakage current
Min Load
Power Factor @ FL
90 ~ 264VAC 120~370 Volts(DC)
47-63 Hz
40Amps / 230VAC
2.5 Amps. @ 115VAC
1.2 Amps. @ 230VAC
< 3.5mAmps / 240VAC
See Selection Chart
PF> 0.96 / 230VAC
0.98 / 115VAC
OUTPUT SPECIFICATIONS
Voltage and Current
Line Regulation
Load Regulation
Voltage Tolerance (Note 2)
Ripple/Noise (Note 1)
Hold Up Time @ FL
Setup, Rise Time @ FL
Over Voltage Protection
Over Current Protection
DC Volt Adjust
See Selection Chart
±0.5%
See Selection Chart
±2.0%: 3.3~15Volts(DC)
±1.0%: 24~48Volts(DC)
See Selection Chart
30mS
600ms, 30mS
3.63 ~ 4.45Volt(DC): 3.3Volts(DC)
5.5 ~ 6.75Volt(DC): 5Volts(DC)
8.25 ~ 10.1Volt(DC): 7.5Volts(DC)
13.2~ 16.2Volt(DC): 12Volts(DC)
14.85 ~ 18.2Volt(DC): 13.5Volts(DC)
16.5~ 20.25Volt(DC): 15Volts(DC)
26.4 ~ 32.4Volt(DC): 24Volts(DC)
29.7 ~ 36.5Volt(DC): 27Volts(DC)
52.8 ~ 64.8Volt(DC): 48Volts(DC)
Shut down o/p voltage,re-power
105 ~ 150% rated output power
Constant current limiting,auto recover
See Selection Chart
EMI
Harmonic Current
Efficiency
Isolation
EMS
series
Compliance to EN55022B (CISPR22B)
Compliance to EN61000-3-2,-3
See Selection Chart
3000VAC Input - Output
1500VAC Input - Ground
500VAC Output - Ground
Compliance to
EN61000-4-2, 3, 4, 5, 6, 8, 11; ENV50204, light Industry Level, Criteria A
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
Storage Temperature
Relative Humidity
Temperature Coefficient
MTBF
Vibration
-10°C to +60°C with cooling FAN
-20°C to +85°C, 10~95% RH
20~90% RH non cond
±0.05% / °C (0-50°C) 191.8KHrs min,MIL-HDBK-217F(25°C)
10~500Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes
PHYSICAL SPECIFICATIONS
Size
Millimeters
222 x 75 x 41
Inches
8.74” x 2.95 ” x 1.61 ”
Weight
21.87 oz (620g)
NOTE
1. Ripple & noise are measured at 20MHz of bandwidth by using a 12”
twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Tolerance : includes set up tolerance, line regulation and load regulation.
GENERAL SPECIFICATIONS
Safety
Insulation Resistance
UL60950-1, TUV EN60950-1 Approved
≥ 100MΩ / 500Volts(DC)
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
150W S i n g l e Ou t put w it h P FC Func t i on
WWW.ASTRODYNETDI.COM
LPP150
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
150W S i n g l e Ou t put w it h P FC Func t i on
WWW.ASTRODYNETDI.COM
LPP150
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
Similar pages