AIMTEC AM1L2424SNZ 1 watt | dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AM1L-NZ
1 Watt | DC-DC Converter
FEATURES:
• Single, Dual, & Dual Separated Models
• SMD Package
• Low ripple and noise
• High efficiency up to 83%
•
•
•
•
Operating temperature -40oC to + 85oC
Input / Output Isolation 1000 & 3000VDC
Pin compatible with multiple manufacturers
RoHS compliant
Models
Single output
Input
Voltage (V)
Output
Voltage
(V)
AM1L-0303S-NZ
AM1L-0305S-NZ
AM1L-0505S-NZ
AM1L-0509S-NZ
AM1L-0512S-NZ
AM1L-0515S-NZ
AM1L-0524S-NZ
AM1L-1205S-NZ
AM1L-1209S-NZ
AM1L-1212S-NZ
AM1L-1215S-NZ
AM1L-2405S-NZ
AM1L-2412S-NZ
AM1L-2424S-NZ
3.0-3.6
3.0-3.6
4.5-5.5
4.5-5.5
4.5-5.5
4.5-5.5
4.5-5.5
10.8-13.2
10.8-13.2
10.8-13.2
10.8-13.2
21.6-26.4
21.6-26.4
21.6-26.4
3.3
5
5
9
12
15
24
5
9
12
15
5
12
24
304
200
200
111
84
67
40
200
111
84
67
200
84
40
AM1L-0505SH30-NZ
AM1L-0509SH30-NZ
AM1L-0512SH30-NZ
AM1L-0515SH30-NZ
AM1L-1205SH30-NZ
AM1L-1212SH30-NZ
AM1L-1215SH30-NZ
4.5-5.5
4.5-5.5
4.5-5.5
4.5-5.5
10.8-13.2
10.8-13.2
10.8-13.2
5
9
12
15
5
12
15
200
111
84
67
200
84
67
Model
Output Current Max
| Min (mA)
Isolation
(VDC)
Efficiency
(%)
30
20
20
11
8
6
4
20
11
8
6
20
8
4
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
70
71
78
74
77
78
73
73
75
79
80
72
83
80
20
11
8
6
20
8
6
3000
3000
3000
3000
3000
3000
3000
70
75
78
80
72
79
81
Models
Dual output
Model
Input Voltage
(V)
Output Voltage
(V)
Output Current Max |
Min (mA)
Isolation
(VDC)
Efficiency
(%)
AM1L-0509D-NZ
AM1L-0512D-NZ
AM1L-0515D-NZ
AM1L-1215D-NZ
AM1L-2415D-NZ
4.5-5.5
4.5-5.5
4.5-5.5
10.8-13.2
21.6-26.4
±9
±12
±15
±15
±15
±56
±42
±33
±33
±33
±6
±4
±3
±3
±3
1000
1000
1000
1000
1000
78
79
78
77
75
AM1L-0505DH30-NZ
AM1L-0509DH30-NZ
AM1L-0512DH30-NZ
AM1L-0515DH30-NZ
AM1L-1212DH30-NZ
AM1L-1215DH30-NZ
4.5-5.5
4.5-5.5
4.5-5.5
4.5-5.5
10.8-13.2
10.8-13.2
±5
±9
±12
±15
±12
±15
±100
±56
±42
±33
±42
±33
±10
±6
±4
±3
±4
±3
3000
3000
3000
3000
3000
3000
72
75
78
79
78
79
www.aimtec.com
F 051e R8.O
Tel: +1 514 620 2722
1 of 7
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1L-NZ
1 Watt | DC-DC Converter
Models
Dual Separated Output
Model
Input
Voltage (V)
Output Voltage
(V)
Output Current Max |
Min (mA)
AM1L-050505D-NZ
4.5-5.5
5/5
100/100
*AM1L-051212D-NZ
4.5-5.5
12/12
42/42
*AM1L-051515D-NZ
4.5-5.5
15/15
33/33
AM1L-121212D-NZ
10.8-13.2
12/12
42/42
*Not recommended for new design
NOTE 1: Add suffix “TR” to a part number when ordering in tape and reel package
10/10
4/4
3/3
4/4
Isolation
(VDC)
Efficiency
(%)
1000
1000
1000
1000
70
79
80
78
NOTE 2: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified
Input Specifications
Parameters
Voltage range
Nominal
Typical
3
5
12
24
Maximum
Units
3.0-3.6
4.5-5.5
10.8-13.2
21.6-26.4
VDC
Filter
Capacitor
Isolation Specifications
Parameters
Tested I/O voltage
Tested V1 output/ V2 output
Capacitance V input/V output
Capacitance V1 output/V2 output
Resistance
Conditions
Typical
60 sec
60 sec
500Vdc
500Vdc
500Vdc
Rated
Units
1000 & 3000
VDC
VDC
pF
pF
MOhm
1000
60
60
> 1000
Output Specifications
Parameters
Conditions
Voltage accuracy
Voltage balance
Short Circuit protection
Line voltage regulation (Single)
Line voltage regulation (Dual)
Line voltage regulation (Dual Separated)
Load voltage regulation (Single)
Load voltage regulation (Dual)
Load voltage regulation (Dual Separated)
Temperature coefficient
Ripple & Noise
See the tolerance graph
Dual Output
Typical
Maximum
±5
±2
Momentary (1sec)
±1.2
±1.2
±1.2
10
10
12.8
±0.03
75
For 1.0% of Vin
For 1.0% of Vin
For 1.0% of Vin
Load 10 – 100%
Load 10 – 100%
Load 10 – 100%
At 20MHz Bandwidth
Units
%
%
100
%
%
%
%
%
%
o
%/ C
mV p-p
If the operating output current is less than 10% of maximum it is recommended to install a load resistor in parallel with the
load to ensure the actual load current meets the minimum load current requirement.
General Specifications
Parameters
Switching frequency
Max Case temperature
Operating temperature
Storage temperature
Cooling
www.aimtec.com
F 051e R8.O
Conditions
Typical
100% load
100
Maximum
+95
Without derating
-40 to +85
-55 to +125
Free air convection
Tel: +1 514 620 2722
2 of 7
Units
KHz
o
C
o
C
o
C
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1L-NZ
1 Watt | DC-DC Converter
General Specifications (continued)
Parameters
Conditions
Typical
Maximum
Units
%
Plastic UL94-VO
1.5
g
Dual Separated
2.1
Single 1000VDC
0.50 x 0.44 x 0.25 inch 12.70 x 11.20 x 6.25 mm
Dual 1000VDC
0.60 x 0.44 x 0.25 inch 15.24 x 11.20 x 6.25 mm
Dual Separated 1000VDC
0.70 x 0.70 x 0.24 inch 17.78 x 17.78 x 6.00 mm
Single and Dual 3000VDC
0.6 x 0.44 x 0.26 inch 15.24 x 11.20 x 6.50 mm
o
>980 000 hrs single, 1 000 000hrs dual (MIL-HDBK -217F, Ground Benign, t=+25 C)
Humidity
Case material
95
Weight
Dimensions (L x W x H)
MTBF
Safety Specifications
Parameters
Agency approvals
Standards
cULus (without 24V models and dual separate models)
CE (for 5 and 12 Vin single models)
IEC/UL 60950-1
Pin Out Specifications
1000VDC
3000VDC
Pin
Single
Pin
Single
Dual
1
2
3
4
5
6
7
8
- V Input
+ V Input
N. C.
- V Output
.+V Output
N.C.
N.C.
N.C.
1
2
3
4
5
6
7
8
9
10
11
12
- V Input
+ V Input
N.C.
Omitted
-V Output
N.C.
N.C.
+V Output
Omitted
N.C.
N.C.
N.C.
- V Input
+ V Input
N.C.
Omitted
Common
-V Output
N.C.
+V Output
Omitted
N.C.
N.C.
N.C.
Pin
1
2
3
4
5
6
7
8
9
10
Dual
- V Input
+ V Input
N. C.
Common
.-V Output
N.C.
+V Output
N.C.
N.C.
N.C.
Pin
Dual
Separated
1
2
3
5
6
7
8
9
10
12
13
14
- V Input
+ V Input
N.C.
- V1 Output
.+V1 Output
N.C
N.C
.+V2 Output
- V2 Output
N.C
N.C
N.C
N.C: Not Connected
www.aimtec.com
F 051e R8.O
Tel: +1 514 620 2722
3 of 7
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1L-NZ
1 Watt | DC-DC Converter
Dimensions Single 1000VDC
Dimensions Dual 1000VDC
Front View
Front View
6.70
(0.26)
Side View
4.13
(0.16)
0.30
(0.01)
6.00
(0.24)
0.30
(0.01)
1.85
(0.07)
Top View
7.00
(0.28)
15.24
(0.60)
A
12.70
(0.50)
A
6.25
(0.25)
0.25
(0.01)
7.00
(0.28)
1.85
(0.07)
Top View
4.13
(0.16)
A
6.00 6.25
(0.24) (0.25)
0.25
(0.01)
6.70
(0.26)
Side View
A
0.50
(0.02)
11.20 7.50
(0.44) (0.30)
11.20 7.50
(0.44) (0.30)
0.50
(0.02)
5.00º angle
1
1
5.00º angle
1.50
(0.06)
0.60
(0.024)
2.54
(0.10)
0.60
(0.024)
2.54
(0.10)
All dimensions are in mm (inch)
All Pins are on a 2.54mm (0.10inch) pitch
with tolerance of ±0.25mm (0.01inch)
All dimensions are in mm (inch)
All Pins are on a 2.54mm (0.10inch) pitch
with tolerance of ±0.25mm (0.01inch)
Dimensions Single and Dual 3000VDC
Dimensions Dual Separated 1000VDC
Front View
Side View
Side View
6.76
(0.27)
4.25
(0.17)
6.25
(0.25)
0.30
(0.01)
15.24
(0.60)
A
5.75 6.00
(0.23) (0.24)
A
0.25
(0.01)
1.35
(0.05)
Front View
2.75
(0.11)
6.50
(0.26)
Top View
1.50
(0.06)
0.25
(0.01)
0.25
(0.01)
12.70
(0.50)
Top View
7.15
(0.28)
17.78
(0.70)
A
A
11.20 7.50
(0.44) (0.30)
0.50
(0.02)
0.50
(0.02)
17.78 12.70
(0.70) (0.50)
5.00º angle
1
1
5.00º angle
2.54
(0.10)
0.60
(0.024)
All dimensions are in mm (inch)
All Pins are on a 2.54mm (0.10inch) pitch
with tolerance of ±0.25mm (0.01inch)
www.aimtec.com
F 051e R8.O
2.54
(0.10)
1.35
(0.05)
1.20
(0.05)
1.80
(0.07)
1.30
(0.05)
All dimensions are in mm (inch)
All Pins are on a 2.54mm (0.10inch) pitch
with tolerance of ±0.25mm (0.01inch)
Tel: +1 514 620 2722
4 of 7
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1L-NZ
1 Watt | DC-DC Converter
Recommended Filter Circuit
Tolerance Graph
L
Single Output
L
+Vout
+ Vin
+
Cin +
DC
DC
Cout
- Vin
- Vin
L
Dual Output
L
+Vout
+ Vin
+
Cin +
DC
Cout
Common
DC
+
L
Cout
- Vin
-Vout
L
Dual Separated Output
L
+V1output
+ Vin
+
Cout
-V1 output
Cin +
DC
DC
L
+V2 output
+
Cout
-V2 output
- Vin
If it is required to decrease the input/output ripple, an “LC” filter network can be installed on the input and output of the
converter (see above).
It should be noted that the inductance and the resonant frequency of the “LC” filtering network should differ from the DC/DC
converter switching frequency to avoid mutual interference.
The capacitance of the output filter capacitor must not exceed the values in the Table below to avoid startup problems and
ensure safe and reliable operation.
It’s not recommended to connect any external capacitor in the application field whenoutput loading is less than 0.5
watt.
External Capacitor Tables
Input Capacitor (Cin)
Vin
(VDC)
Cin
(uF)
5
12
4.7
2.2
www.aimtec.com
F 051e R8.O
Output Capacitor (Cout)
Single
Vout
(VDC)
5
9
12
15
Cout
(uF)
Dual
Vout
(Vdc)
Cout
(uF)
Dual
SeperatedV
out (Vdc)
Cout
(uF)
10
4.7
2.2
1
±5
±9
±12
±15
4.7
2.2
1
0.47
5/5
9/9
12/12
15/15
4.7
2.2
1
0.47
Tel: +1 514 620 2722
5 of 7
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1L-NZ
1 Watt | DC-DC Converter
Typical Efficiency vs. Loading
Eff %
AM1L-0303S-NZ Efficiency vs. Loading
100
90
80
70
60
50
40
30
20
10
0
10%
20%
30%
40%
50%
60%
70%
80%
90% 100%
Loading %
Eff %
AM1L-0505S-NZ Efficiency vs. Loading
100
90
80
70
60
50
40
30
20
10
0
10%
20%
30%
40%
50%
60%
70%
80%
90% 100%
Loading %
www.aimtec.com
F 051e R8.O
Tel: +1 514 620 2722
6 of 7
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1L-NZ
1 Watt | DC-DC Converter
Eff %
AM1L-1212S-NZ Efficiency vs. Loading
100
90
80
70
60
50
40
30
20
10
0
10%
20%
30%
40%
50%
60%
70%
80%
90% 100%
Loading %
Eff %
AM1L-2424S-NZ Efficiency vs. Loading
100
90
80
70
60
50
40
30
20
10
0
10%
20%
30%
40%
50%
60%
70%
80%
90% 100%
Loading %
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4.All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R8.O
Tel: +1 514 620 2722
7 of 7
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only