19-4629; Rev 3; 5/09 DS3106 Line Card Timing IC General Description The DS3106 is a low-cost timing IC for telecom line cards. The device accepts two reference clocks from dual redundant system timing cards, continually monitors both inputs, and performs manual reference switching if the primary reference fails. The highly programmable DS3106 supports numerous input and output frequencies including frequencies required for SONET/SDH, Synchronous Ethernet (1G, 10G, and 100Mbps), wireless base stations, and CMTS systems. PLL bandwidths from 18Hz to 400Hz are supported, and a wide variety of PLL characteristics and device features can be configured to meet the needs of many different applications. The DS3106 register set is backward compatible with Semtech’s ACS8526 line card timing IC. The DS3106 pinout is similar but not identical to the ACS8526. Features Advanced DPLL Technology Two Input Clocks SONET/SDH, Synchronous Ethernet, PDH, and Other Line Cards in WAN Equipment Including MSPPs, Ethernet Switches, Routers, DSLAMs, and Wireless Base Stations Simplified Functional Diagram IC3 DS3106 OC3 IC4 OC6 LVDS/LVPECL FSYNC MFSYNC CMOS/TTL Signal Format (≤ 125MHz) Numerous Input Clock Frequencies Supported Ethernet xMII: 2.5, 25, 125, 156.25MHz SONET/SDH: 6.48, N x 19.44, N x 51.84MHz PDH: N x DS1, N x E1, N x DS2, DS3, E3 Frame Sync: 2kHz, 4kHz, 8kHz Custom Clock Rates: Any Multiple of 2kHz Up to 125MHz Two Output Clocks Applications Programmable PLL Bandwidth: 18Hz to 400Hz Manual Reference Switching Holdover on Loss of All Input References Frequency Conversion Among SONET/SDH, PDH, Ethernet, Wireless, and CMTS Rates One CMOS/TTL Output (≤ 125MHz) One LVDS/LVPECL Output (≤ 312.50MHz) Two Optional Frame-Sync Outputs: 2kHz, 8kHz Numerous Output Clock Frequencies Supported Ethernet xMII: 2.5, 25, 125, 156.25, 312.5MHz SONET/SDH: 6.48, N x 19.44, N x 51.84MHz PDH: N x DS1, N x E1, N x DS2, DS3, E3 Other: 10, 10.24, 13, 30.72MHz Frame Sync: 2kHz, 8kHz Custom Clock Rates: Any Multiple of 2kHz Up to 77.76MHz, Any Multiple of 8kHz Up to 311.04MHz, Any Multiple of 10kHz Up to 388.79MHz General Suitable Line Card IC for Stratum 3/3E/4, SMC, SEC Internal Compensation for Master Clock Oscillator SPI™ Processor Interface 1.8V Operation with 3.3V I/O (5V Tolerant) Industrial Operating Temperature Range Ordering Information PART LOCAL OSCILLATOR CONTROL STATUS DS3106LN DS3106LN+ TEMP RANGE PIN-PACKAGE -40C to +85C -40C to +85C 64 LQFP 64 LQFP +Denotes a lead(Pb)-free/RoHS-compliant package. SPI is a trademark of Motorola, Inc. Maxim Integrated Products 1 Some revisions of this device may incorporate deviations from published specifications known as errata. Multiple revisions of any device may be simultaneously available through various sales channels. For information about device errata, go to: www.maxim-ic.com/errata. For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com. ____________________________________________________________________________________________ DS3106 Table of Contents 1. STANDARDS COMPLIANCE ..........................................................................................................6 2. APPLICATION EXAMPLE ...............................................................................................................7 3. BLOCK DIAGRAM ...........................................................................................................................7 4. DETAILED DESCRIPTION ..............................................................................................................8 5. DETAILED FEATURES ...................................................................................................................9 5.1 5.2 5.3 5.4 5.5 INPUT CLOCK FEATURES .................................................................................................................9 DPLL FEATURES .............................................................................................................................9 OUTPUT APLL FEATURES ...............................................................................................................9 OUTPUT CLOCK FEATURES ..............................................................................................................9 GENERAL FEATURES .......................................................................................................................9 6. PIN DESCRIPTIONS ......................................................................................................................10 7. FUNCTIONAL DESCRIPTION .......................................................................................................14 7.1 7.2 7.3 7.4 OVERVIEW ....................................................................................................................................14 DEVICE IDENTIFICATION AND PROTECTION .....................................................................................14 LOCAL OSCILLATOR AND MASTER CLOCK CONFIGURATION.............................................................14 INPUT CLOCK CONFIGURATION ......................................................................................................15 7.4.1 7.4.2 7.5 INPUT CLOCK MONITORING ............................................................................................................16 7.5.1 7.5.2 7.5.3 7.6 7.7 Frequency Monitoring .......................................................................................................................... 16 Activity Monitoring ................................................................................................................................ 16 Selected Reference Activity Monitoring ............................................................................................... 17 INPUT CLOCK PRIORITY AND SWITCHING ........................................................................................17 DPLL ARCHITECTURE AND CONFIGURATION ..................................................................................18 7.7.1 7.7.2 7.7.3 7.7.4 7.7.5 7.7.6 7.7.7 7.7.8 7.7.9 7.8 Signal Format Configuration ................................................................................................................ 15 Frequency Configuration...................................................................................................................... 15 T0 DPLL State Machine ....................................................................................................................... 19 Bandwidth ............................................................................................................................................ 22 Damping Factor.................................................................................................................................... 22 Phase Detectors................................................................................................................................... 22 Loss-of-Lock Detection ........................................................................................................................ 23 Frequency and Phase Measurement................................................................................................... 24 Input Jitter Tolerance ........................................................................................................................... 24 Jitter Transfer ....................................................................................................................................... 24 Output Jitter and Wander ..................................................................................................................... 24 OUTPUT CLOCK CONFIGURATION...................................................................................................24 7.8.1 7.8.2 Signal Format Configuration ................................................................................................................ 25 Frequency Configuration...................................................................................................................... 25 7.9 MICROPROCESSOR INTERFACE ......................................................................................................33 7.10 RESET LOGIC .............................................................................................................................36 7.11 POWER-SUPPLY CONSIDERATIONS .............................................................................................36 7.12 INITIALIZATION............................................................................................................................36 8. REGISTER DESCRIPTIONS .........................................................................................................37 8.1 8.2 8.3 8.4 STATUS BITS .................................................................................................................................37 CONFIGURATION FIELDS ................................................................................................................37 MULTIREGISTER FIELDS .................................................................................................................37 REGISTER DEFINITIONS .................................................................................................................38 19-4629; Rev 3; 5/09 2 of 87 ____________________________________________________________________________________________ DS3106 9. JTAG TEST ACCESS PORT AND BOUNDARY SCAN ...............................................................70 9.1 9.2 9.3 9.4 10. JTAG DESCRIPTION ......................................................................................................................70 JTAG TAP CONTROLLER STATE MACHINE DESCRIPTION ...............................................................71 JTAG INSTRUCTION REGISTER AND INSTRUCTIONS ........................................................................73 JTAG TEST REGISTERS ................................................................................................................74 ELECTRICAL CHARACTERISTICS..............................................................................................75 10.1 10.2 10.3 10.4 10.5 10.6 DC CHARACTERISTICS ...............................................................................................................75 INPUT CLOCK TIMING .................................................................................................................78 OUTPUT CLOCK TIMING ..............................................................................................................78 SPI INTERFACE TIMING ..............................................................................................................79 JTAG INTERFACE TIMING ...........................................................................................................81 RESET PIN TIMING .....................................................................................................................82 11. PIN ASSIGNMENTS ......................................................................................................................83 12. PACKAGE INFORMATION ...........................................................................................................85 13. THERMAL INFORMATION ............................................................................................................85 14. ACRONYMS AND ABBREVIATIONS ...........................................................................................86 15. DATA SHEET REVISION HISTORY..............................................................................................87 19-4629; Rev 3; 5/09 3 of 87 ____________________________________________________________________________________________ DS3106 List of Figures Figure 2-1. Typical Application Example ..................................................................................................................... 7 Figure 3-1. Block Diagram ........................................................................................................................................... 7 Figure 7-1. DPLL Block Diagram ............................................................................................................................... 18 Figure 7-2. T0 DPLL State Transition Diagram ......................................................................................................... 20 Figure 7-3. FSYNC 8kHz Options.............................................................................................................................. 32 Figure 7-4. SPI Clock Phase Options ........................................................................................................................ 35 Figure 7-5. SPI Bus Transactions.............................................................................................................................. 35 Figure 9-1. JTAG Block Diagram............................................................................................................................... 70 Figure 9-2. JTAG TAP Controller State Machine ...................................................................................................... 72 Figure 10-1. Recommended Termination for LVDS Output Pins .............................................................................. 77 Figure 10-2. Recommended Termination for LVPECL-Compatible Output Pins ...................................................... 77 Figure 10-3. SPI Interface Timing Diagram ............................................................................................................... 80 Figure 10-4. JTAG Timing Diagram........................................................................................................................... 81 Figure 10-5. Reset Pin Timing Diagram .................................................................................................................... 82 Figure 11-1. Pin Assignment Diagram....................................................................................................................... 84 19-4629; Rev 3; 5/09 4 of 87 ____________________________________________________________________________________________ DS3106 List of Tables Table 1-1. Applicable Telecom Standards................................................................................................................... 6 Table 6-1. Input Clock Pin Descriptions .................................................................................................................... 10 Table 6-2. Output Clock Pin Descriptions.................................................................................................................. 10 Table 6-3. Global Pin Descriptions ............................................................................................................................ 11 Table 6-4. SPI Bus Mode Pin Descriptions ............................................................................................................... 12 Table 6-5. JTAG Interface Pin Descriptions .............................................................................................................. 12 Table 6-6. Power-Supply Pin Descriptions ................................................................................................................ 13 Table 7-1. Input Clock Capabilities ............................................................................................................................ 15 Table 7-2. Input Clock Default Frequency Configuration........................................................................................... 15 Table 7-3. Locking Frequency Modes ....................................................................................................................... 15 Table 7-4. Damping Factors and Peak Jitter/Wander Gain....................................................................................... 22 Table 7-5. Output Clock Capabilities ......................................................................................................................... 24 Table 7-6. Digital1 Frequencies................................................................................................................................. 26 Table 7-7. Digital2 Frequencies................................................................................................................................. 26 Table 7-8. APLL Frequency to Output Frequencies (T0 APLL and T4 APLL) .......................................................... 27 Table 7-9. T0 APLL Frequency Configuration ........................................................................................................... 27 Table 7-10. T0 APLL2 Frequency Configuration ....................................................................................................... 27 Table 7-11. T4 APLL Frequency Configuration ......................................................................................................... 28 Table 7-12. OC3 and OC6 Output Frequency Selection ........................................................................................... 28 Table 7-13. Standard Frequencies for Programmable Outputs ................................................................................ 29 Table 7-14. T0FREQ Default Settings ....................................................................................................................... 31 Table 7-15. T4FREQ Default Settings ....................................................................................................................... 31 Table 7-16. OC6 Default Frequency Configuration ................................................................................................... 31 Table 7-17. OC3 Default Frequency Configuration ................................................................................................... 32 Table 8-1. Register Map ............................................................................................................................................ 38 Table 9-1. JTAG Instruction Codes ........................................................................................................................... 73 Table 9-2. JTAG ID Code .......................................................................................................................................... 74 Table 10-1. Recommended DC Operating Conditions .............................................................................................. 75 Table 10-2. DC Characteristics.................................................................................................................................. 75 Table 10-3. CMOS/TTL Pins ..................................................................................................................................... 76 Table 10-4. LVDS Output Pins .................................................................................................................................. 76 Table 10-5. LVPECL Level-Compatible Output Pins................................................................................................. 77 Table 10-6. Input Clock Timing.................................................................................................................................. 78 Table 10-7. Input Clock to Output Clock Delay ......................................................................................................... 78 Table 10-8. Output Clock Phase Alignment, Frame-Sync Alignment Mode.............................................................. 78 Table 10-9. SPI Interface Timing ............................................................................................................................... 79 Table 10-10. JTAG Interface Timing.......................................................................................................................... 81 Table 10-11. Reset Pin Timing .................................................................................................................................. 82 Table 11-1. Pin Assignments Sorted by Signal Name............................................................................................... 83 Table 13-1. LQFP Package Thermal Properties, Natural Convection....................................................................... 85 Table 13-2. LQFP Theta-JA (JA) vs. Airflow ............................................................................................................. 85 19-4629; Rev 3; 5/09 5 of 87 ____________________________________________________________________________________________ DS3106 1. Standards Compliance Table 1-1. Applicable Telecom Standards SPECIFICATION ANSI T1.101 TIA/EIA-644-A ETSI EN 300 417-6-1 EN 300 462-3-1 EN 300 462-5-1 IEEE IEEE 1149.1 ITU-T G.783 G.813 G.823 G.824 G.825 G.8261 G.8262 TELCORDIA GR-253-CORE GR-1244-CORE 19-4629; Rev 3; 5/09 SPECIFICATION TITLE Synchronization Interface Standard, 1999 Electrical Characteristics of Low Voltage Differential Signaling (LVDS) Interface Circuits, 2001 Transmission and Multiplexing (TM); Generic requirements of transport functionality of equipment; Part 6-1: Synchronization layer functions, v1.1.3 (1999-05) Transmission and Multiplexing (TM); Generic requirements for synchronization networks; Part 3-1: The control of jitter and wander within synchronization networks, v1.1.1 (1998-05) Transmission and Multiplexing (TM); Generic requirements for synchronization networks; Part 5-1: Timing characteristics of slave cocks suitable for operation in Synchronous Digital Hierarchy (SDH) Equipment, v1.1.2 (1998-05) Standard Test Access Port and Boundary-Scan Architecture, 1990 Characteristics of synchronous digital hierarchy (SDH) equipment functional blocks (10/2000 plus Amendment 1 06/2002 and Corrigendum 2 03/2003) Timing characteristics of SDH equipment slave clocks (SEC) (03/2003) The control of jitter and wander within digital networks which are based on the 2048 kbit/s hierarchy (03/2000) The control of jitter and wander within digital networks which are based on the 1544 kbit/s hierarchy (03/2000) The control of jitter and wander within digital networks which are based on the synchronous digital hierarchy (SDH) (03/2000) Timing and synchronization aspects in packet networks (05/2006, prepublished) Timing characteristics of synchronous Ethernet equipment slave clock (EEC) (08/2007, prepublished) SONET Transport Systems: Common Generic Criteria, Issue 3, September 2000 Clocks for the Synchronized Network: Common Generic Criteria, Issue 2, December 2000 6 of 87 ____________________________________________________________________________________________ DS3106 2. Application Example Figure 2-1. Typical Application Example prog. bandwidth, manual reference switching, holdover, etc. DS3106 From Master Timing Card From Slave Timing Card 19.44 MHz 19.44 MHz IC3 IC4 Input Clock Selector, Divider, Monitor T0 DPLL Output Clock Synthesizer and Selector 19.44 MHz OC3 OC6 155.52MHz differential To SONET/SDH framers, Clock Multiplying APLLs, etc. on the Line Card XO or TCXO 3. Block Diagram Figure 3-1. Block Diagram Input Clock Selector, Divider and Monitor Microprocessor Port JTAG (SPI Serial) and HW Control and Status Pins RST* TEST JTRST* JTMS JTCLK JTDI JTDO 19-4629; Rev 3; 5/09 (Filtering, Holdover, Frequency Conversion) INTREQ / SRFAIL SRCSW SONSDH / GPIO4 O6F[2:0] / GPIO[3:1] IPF[2:0] O3F[0] O3F[1] / SRFAIL O3F[2] / LOCK IC4 T0 DPLL CPHA CS SCLK SDI SDO IC3 Output Clock Synthesizer and Selector OC3 OC6 POS/NEG FSYNC (Muxes, 7 DFS Blocks, 3 APLLs, Output Dividers) Master Clock Generator MFSYNC DS3106 REFCLK Local Oscillator 7 of 87 ____________________________________________________________________________________________ DS3106 4. Detailed Description Figure 3-1 illustrates the blocks described in this section and how they relate to one another. Section 5 provides a detailed feature list. The DS3106 is a complete line card timing IC. At the core of this device is a digital phase-locked loop (DPLL). DPLL technology makes use of digital-signal processing (DSP) and digital-frequency synthesis (DFS) techniques to implement PLLs that are precise, flexible, and have consistent performance over voltage, temperature, and manufacturing process variations. The DS3106’s T0 1 DPLL is digitally configurable for input and output frequencies, loop bandwidth, damping factor, pull-in/hold-in range, and a variety of other factors. The T0 DPLL can directly lock to many common telecom frequencies and also can lock at 8kHz to any multiple of 8kHz up to 156.25MHz. The DPLL can also tolerate and filter significant amounts of jitter and wander. In typical line card applications, the T0 DPLL takes reference clock signals from two redundant system timing cards, monitors both, selects one, and uses that reference to produce a variety of clocks that are needed to time the outgoing traffic interfaces of the line card (SONET/SDH, Synchronous Ethernet, etc.). To perform this role in a variety of systems with diverse performance requirements, the T0 DPLL has a sophisticated feature set and is highly configurable. T0 can automatically transition among free-run, locked, and holdover states without software intervention. In free-run, T0 generates a stable, low-noise clock with the same frequency accuracy as the external oscillator connected to the REFCLK pin. With software calibration the DS3106 can even improve the accuracy to within 0.02ppm. When the selected input reference clock has been validated, T0 transitions to the locked state in which its output clock accuracy is equal to the accuracy of the input reference. While in the locked state, T0 acquires an average frequency value to use as the holdover frequency. When its selected reference fails, T0 can very quickly detect the failure and enter the holdover state to avoid affecting its output clock. From holdover it can be manually switched to another input reference. When all input references are lost, T0 stays in the holdover state, in which it generates a stable low-noise clock with initial frequency accuracy equal to its stored holdover value and drift performance determined by the quality of the external oscillator. At the front end of the T0 DPLL is the Input Clock Selector, Divider, and Monitor (ICSDM) block. This block continuously monitors both input clocks for activity and coarse frequency accuracy. In addition, ICSDM can manually select one of the input clocks to be the selected reference for the T0 DPLL. The ICSDM block can also divide the selected clock down to a lower rate as needed by the DPLL. The Output Clock Synthesizer and Selector (OCSS) block shown in Figure 3-1 and in more detail in Figure 7-1 contains three output APLLs—T0 APLL, T0 APLL2, and T4 APLL—and their associated DFS engines and output divider logic plus several additional DFS engines. The APLL DFS blocks perform frequency translation, creating clocks of other frequencies that are phase/frequency locked to the output clock of the T0 DPLL. The APLLs multiply the clock rates from the APLL DFS blocks and simultaneously attenuate jitter. Altogether the output blocks of the DS3106 can produce more than 90 different output frequencies including common SONET/SDH, PDH, and Synchronous Ethernet rates plus 2kHz and 8kHz frame-sync pulses. The entire chip is clocked from the external oscillator connected to the REFCLK pin. Thus, the free-run and holdover stability of the DS3106 is entirely a function of the stability of the external oscillator, the performance of which can be selected to match the application: typically XO or TCXO. The 12.8MHz clock from the external oscillator is multiplied by 16 by the Master Clock Generator block to create the 204.8MHz master clock used by the remainder of the device. 1 The labels T0 and T4 in this document are adapted from output ports of the SETS function specified in ITU-T and ETSI standards such as ETSI EN 300 462-2-1. Although strictly speaking these names are appropriate only for timing card ICs such as the DS3100 that can serve as the SETS function, the names have been carried over to the DS3106 so that all of the products in Maxim’s timing IC product line have consistent nomenclature. 19-4629; Rev 3; 5/09 8 of 87 ____________________________________________________________________________________________ DS3106 5. Detailed Features 5.1 5.2 5.3 5.4 Input Clock Features Two programmable-frequency CMOS/TTL input clocks Input clocks accept any multiple of 2kHz up to 125MHz All input clocks are constantly monitored by programmable activity monitors DPLL Features High-resolution DPLL plus three low-jitter output APLLs Sophisticated state machine automatically transitions between free-run, locked, and holdover states Programmable bandwidth from 18Hz to 400Hz Separately configurable acquisition bandwidth and locked bandwidth Programmable damping factor to balance lock time with peaking: 1.2, 2.5, 5, 10, or 20 Multiple phase detectors: phase/frequency, early/late, and multicycle Phase/frequency locking (360 capture) or nearest edge phase locking (180 capture) Multicycle phase detection and locking (up to 8191UI) improves jitter tolerance and lock time High-resolution frequency and phase measurement Holdover frequency averaging over 1 second interval Fast detection of input clock failure and transition to holdover mode Low-jitter frame sync (8kHz) and multiframe sync (2kHz) aligned with output clocks Output APLL Features Three separate clock-multiplying, jitter attenuating APLLs can simultaneously produce SONET/SDH rates, Fast/Gigabit Ethernet rates, and 10G Ethernet rates, all locked to a common reference clock The T0 APLL has frequency options suitable for N x 19.44MHz, N x DS1, N x E1, N x 25MHz, and N x 62.5MHz The T4 APLL has frequency options suitable for N x 19.44MHz, N x DS1, N x E1, N x DS2, DS3, E3, N x 10MHz, N x 10.24MHz, N x 13MHz, N x 25MHz, and N x 62.5MHz The T0 APLL2 produces 312.5MHz for 10G Synchronous Ethernet applications Output Clock Features Two output clocks: one CMOS/TTL (≤ 125MHz) and one LVDS/LVPECL (≤ 312.50MHz) Output clock rates include 2kHz, 8kHz, N x DS1, N x E1, DS2, DS3, E3, 6.48MHz, 19.44MHz, 38.88MHz, 51.84MHz, 77.76MHz, 155.52MHz, 311.04MHz, 2.5MHz, 25MHz, 125MHz, 156.25MHz, 312.50MHz, 10MHz, 10.24MHz, 13MHz, 30.72MHz, and various multiples and submultiples of these rates Custom clock rates also available: any multiple of 2kHz up to 77.76MHz, any multiple of 8kHz up to 311.04MHz, and any multiple of 10kHz up to 388.79MHz 5.5 All outputs have < 1ns peak-to-peak output jitter; outputs from APLLs have < 0.5ns peak-to-peak 8kHz frame-sync and 2kHz multiframe-sync outputs have programmable polarity and pulse width, and can be disciplined by a 2kHz or 8kHz sync input General Features Operates from a single external 12.800MHz local oscillator (XO or TCXO) SPI serial microprocessor interface Four general-purpose I/O pins Register set can be write protected 19-4629; Rev 3; 5/09 9 of 87 ____________________________________________________________________________________________ DS3106 6. Pin Descriptions Table 6-1. Input Clock Pin Descriptions PIN NAME (1) TYPE REFCLK I IC3 IPD IC4 IPD (2) PIN DESCRIPTION Reference Clock. Connect to a 12.800MHz, high-accuracy, high-stability, low-noise local oscillator (XO or TCXO). See Section 7.3. Input Clock 3. CMOS/TTL. Programmable frequency. Default frequency selected by IPF[2:0] pins when the RST pin goes high, 8kHz if IPF[2:0] pins left open. Input Clock 4. CMOS/TTL. Programmable frequency. Default frequency selected by IPF[2:0] pins when the RST pin goes high, 8kHz if IPF[2:0] pins left open. Table 6-2. Output Clock Pin Descriptions PIN NAME (1) TYPE (2) OC3 O OC6POS, OC6NEG ODIFF FSYNC O3 MFSYNC O3 19-4629; Rev 3; 5/09 PIN DESCRIPTION Output Clock 3. CMOS/TTL. Programmable frequency. Default frequency selected by O3F[2:0] pins when the RST pin goes high, 19.44MHz if O3F[2:0] pins left open. See Table 7-17. Output Clock 6. LVDS/LVPECL. Programmable frequency. Default frequency selected by O6F[2:0] pins when the RST pin goes high, 38.88MHz if O6F[2:0] pins left open. The output mode is selected by MCR8.OC6SF[1:0]. See Table 10-4, Table 10-5, Figure 10-1, and Figure 10-2. 8kHz FSYNC. CMOS/TTL. 8kHz frame sync or clock (default 50% duty cycle clock, noninverted). The pulse polarity and width are selectable using FSCR1.8KINV and FSCR1.8KPUL. 2kHz MFSYNC. CMOS/TTL. 2kHz frame sync or clock (default 50% duty cycle clock, noninverted). The pulse polarity and width are selectable using FSCR1.2KINV and FSCR1.2KPUL. 10 of 87 ____________________________________________________________________________________________ DS3106 Table 6-3. Global Pin Descriptions PIN NAME(1) TYPE(2) RST IPU SRCSW IPD TEST IPD IPF0 IPD IPF1 IPD IPF2 IPD O3F0 IPU O3F1/SRFAIL O3F2/LOCK O6F0/GPIO1 O6F1/GPIO2 O6F2/GPIO3 19-4629; Rev 3; 5/09 PIN DESCRIPTION Reset (Active Low). When this global asynchronous reset is pulled low, all internal circuitry is reset to default values. The device is held in reset as long as RST is low. RST should be held low for at least two REFCLK cycles after the external oscillator has stabilized and is providing valid clock signals. Source Switching. Input reference selection pin. Selects IC3 when high and IC4 when low. See Section 7.6. Factory Test Mode Select. Wire this pin to VSS for normal operation. Input Frequency Select 0. Together with IPF1 and IPF2, this pin sets the default frequency of the IC3 and IC4 input clock pins. The value is sampled when RST goes high, and the FREQ[3:0] fields of ICR3 and ICR4 are set accordingly. See Table 7-2. After RST goes high this pin is ignored. Input Frequency Select 1. Together with IPF0 and IPF2, this pin sets the default frequency of the IC3 and IC4 input clock pins. The value is sampled when RST goes high, and the FREQ[3:0] fields of ICR3 and ICR4 are set accordingly. See Table 7-2. After RST goes high this pin is ignored. Input Frequency Select 2. Together with IPF0 and IPF1, this pin sets the default frequency of the IC3 and IC4 input clock pins. The value is sampled when RST goes high, and the FREQ[3:0] fields of ICR3 and ICR4 are set accordingly. See Table 7-2. After RST goes high this pin is ignored. OC3 Frequency Select 0. This pin is sampled when the RST pin goes high and the value is used as O3F0, which, together with O3F2 and O3F1, sets the default frequency of the OC3 output clock pin. See Table 7-17. After RST goes high this pin is ignored. IOPU OC3 Frequency Select 1/SRFAIL Status Pin. This pin is sampled when the RST pin goes high and the value is used as O3F1, which, together with O3F2 and O3F0, sets the default frequency of the OC3 output clock pin. See Table 7-17. After RST goes high, if MCR10:SRFPIN = 1, this pin follows the state of the SRFAIL status bit in the MSR2 register. This gives the system a very fast indication of the failure of the selected reference. When MCR10:SRFPIN = 0, SRFAIL is disabled (low). IOPD OC3 Frequency Select 2/T0 DPLL LOCK Status. This pin is sampled when the RST pin goes high and the value is used as O3F2, which, together with O3F1 and O3F0, sets the default frequency of the OC3 output clock pin. See Table 7-17. After RST goes high, if MCR1.LOCKPIN = 1, this pin indicates the lock state of the T0 DPLL. When MCR1.LOCKPIN = 0, LOCK is disabled (low). 0 = Not locked 1 = Locked IOPD OC6 Frequency Select 0/General-Purpose I/O Pin 1. This pin is sampled when the RST pin goes high and the value is used as O6F0, which, together with O6F2 and O6F1, sets the default frequency of the OC6 output clock pin. See Table 7-16. After RST goes high, this pin can be used as a general-purpose I/O pin. GPCR:GPIO1D configures this pin as an input or an output. GPCR:GPIO1O specifies the output value. GPSR:GPIO1 indicates the state of the pin. IOPD OC6 Frequency Select 1/General-Purpose I/O Pin 2. This pin is sampled when the RST pin goes high and the value is used as O6F1, which, together with O6F2 and O6F0, sets the default frequency of the OC6 output clock pin. See Table 7-16. After RST goes high, this pin can be used as a general-purpose I/O pin. GPCR:GPIO2D configures this pin as an input or an output. GPCR:GPIO2O specifies the output value. GPSR:GPIO2 indicates the state of the pin. IOPU OC6 Frequency Select 2/General-Purpose I/O Pin 3. This pin is sampled when the RST pin goes high and the value is used as O6F2, which, together with O6F1 and O6F0, sets the default frequency of the OC6 output clock pin. See Table 7-16. After RST goes high, this pin can be used as a general-purpose I/O pin. GPCR:GPIO3D configures this pin as an input or an output. GPCR:GPIO3O specifies the output value. GPSR:GPIO3 indicates the state of the pin. 11 of 87 ____________________________________________________________________________________________ DS3106 PIN NAME(1) TYPE(2) PIN DESCRIPTION IOPD SONET/SDH Frequency Select Input/General-Purpose I/O 4. When RST goes high the state of this pin sets the reset-default state of MCR3:SONSDH, MCR6:DIG1SS, and MCR6:DIG2SS. After RST goes high, this pin can be used as a general-purpose I/O pin. GPCR:GPIO4D configures this pin as an input or an output. GPCR:GPIO4O specifies the output value. GPSR:GPIO4 indicates the state of the pin. SONSDH/ GPIO4 Reset latched values: 0 = SDH rates (N x 2.048MHz) 1 = SONET rates (N x 1.544MHz) Interrupt Request/Loss of Signal. Programmable (default: INTREQ). The INTCR:LOS bit determines whether the pin indicates interrupt requests or loss of signal (i.e., loss of selected reference). INTREQ/LOS O3 INTCR:LOS = 0: INTREQ mode The behavior of this pin is configured in the INTCR register. Polarity can be active high or active low. Drive action can be push-pull or open drain. The pin can also be configured as a general-purpose output if the interrupt request function is not needed. INTCR:LOS = 1: LOS mode This pin indicates the real-time state of the selected reference activity monitor (see Section 7.5.3). Table 6-4. SPI Bus Mode Pin Descriptions See Section 7.9 for functional description and Section 10.4 for timing specifications. PIN NAME(1) TYPE(2) PIN DESCRIPTION CS IPU Chip Select. This pin must be asserted (low) to read or write internal registers. SCLK SDI SDO I I O CPHA I Serial Clock. SCLK is always driven by the SPI bus master. Serial Data Input. The SPI bus master transmits data to the device on this pin. Serial Data Output. The device transmits data to the SPI bus master on this pin. Clock Phase. See Figure 7-4. 0 = Data is latched on the leading edge of the SCLK pulse. 1 = Data is latched on the trailing edge of the SCLK pulse. Table 6-5. JTAG Interface Pin Descriptions See Section 9 for functional description and Section 10.5 for timing specifications. PIN NAME(1) TYPE(2) JTRST IPU JTCLK I JTDI IPU JTDO O3 JTMS IPU 19-4629; Rev 3; 5/09 PIN DESCRIPTION JTAG Test Reset (Active Low). Asynchronously resets the test access port (TAP) controller. If not used, JTRST can be held low or high. JTAG Clock. Shifts data into JTDI on the rising edge and out of JTDO on the falling edge. If not used, JTCLK can be held low or high. JTAG Test Data Input. Test instructions and data are clocked in on this pin on the rising edge of JTCLK. If not used, JTDI can be held low or high. JTAG Test Data Output. Test instructions and data are clocked out on this pin on the falling edge of JTCLK. If not used, leave floating. JTAG Test Mode Select. Sampled on the rising edge of JTCLK and is used to place the port into the various defined IEEE 1149.1 states. If not used connect to VDDIO or leave floating. 12 of 87 ____________________________________________________________________________________________ DS3106 Table 6-6. Power-Supply Pin Descriptions PIN NAME(1) VDD VDDIO VSS AVDD_DL AVSS_DL VDD_OC6 VSS_OC6 AVDD_PLL1 AVSS_PLL1 AVDD_PLL2 AVSS_PLL2 AVDD_PLL3 AVSS_PLL3 AVDD_PLL4 AVSS_PLL4 TYPE(2) P P P P P P P P P P P P P P P PIN DESCRIPTION Core Power Supply. 1.8V 10%. I/O Power Supply. 3.3V 5%. Ground Reference Power Supply for OC6 Digital Logic. 1.8V 10%. Return for OC6 Digital Logic Power Supply for Differential Output OC6POS/NEG. 1.8V 10%. Return for LVDS Differential Output OC6POS/NEG Power Supply for Master Clock Generator APLL. 1.8V 10%. Return for Master Clock Generator APLL Power Supply for T0 APLL. 1.8V 10%. Return for T0 APLL Power Supply for T4 APLL. 1.8V 10%. Return for T4 APLL Power Supply for T0 APLL2. 1.8V 10%. Return for T0 APLL2 Note 1: All pin names with an overbar (e.g., RST) are active low. Note 2: All pins, except power and analog pins, are CMOS/TTL, unless otherwise specified in the pin description. PIN TYPES I = input pin IDIFF = input pin that is LVDS/LVPECL differential signal compatible IPD = input pin with internal 50k pulldown IPU = input pin with internal 50k pullup I/O = input/output pin IOPD = input/output pin with internal 50k pulldown IOPU = input/output pin with internal 50k pullup O = output pin O3 = output pin that can be placed in a high-impedance state ODIFF = output pin that is LVDS/LVPECL differential signal compatible P = power-supply pin Note 3: All digital pins, except OCn, are I/O pins in JTAG mode. OCn pins do not have JTAG functionality. 19-4629; Rev 3; 5/09 13 of 87 ____________________________________________________________________________________________ DS3106 7. Functional Description 7.1 Overview The DS3106 has two input clocks, two output clocks, and a high-performance DPLL known as T0. Figure 3-1. The two input clocks are CMOS/TTL (5V tolerant) and can accept signals from 2kHz to 125MHz. Each input clock is monitored continually for activity. SRFAIL is set or cleared based on the activity of the selected input. The T0 DPLL can directly lock to many common datacom and telecom frequencies, including, but not limited to, 8kHz, DS1, E1, 10MHz, 19.44MHz, and 38.88MHz, as well as Ethernet frequencies including 25MHz, 62.5MHz, and 125MHz. The DPLL can also lock to multiples of the standard direct-lock frequencies including 8kHz. The T0 DPLL has all the features needed for synchronizing a line card to dual redundant system timing cards. The T0 DPLL includes these features: A full state machine for automatic transitions among free-run, locked, and holdover states Adjustable PLL characteristics, including bandwidth, pull-in range, and damping factor Six bandwidth selections from 18Hz to 400Hz Frequency conversion between input and output using digital frequency synthesis Combined performance of a stable, consistent digital PLL and low-jitter analog output PLLs Ability to lock to several common telecom and Ethernet frequencies plus multiples of the standard direct lock frequencies including 8kHz Instant digital one-second averaging and free-run holdover modes Typically, the internal state machine controls the T0 DPLL, but manual control by system software is also available. The outputs of the T0 DPLL can be connected to seven output DFS engines. See Figure 7-1. Three of these output DFS engines are associated with high-speed APLLs that multiply the DPLL clock rate and filter DPLL output jitter. The outputs of the APLLs are divided down to make a wide variety of possible frequencies available at the output clock pins. The OC3 and OC6 output clocks can be configured for a variety of different frequencies that are frequency- and phase-locked to the T0 DPLL. The OC6 output is LVDS/LVPECL. The OC3 output is CMOS/TTL. Altogether more than 60 output frequencies are possible, ranging from 2kHz to 312.5MHz. The FSYNC output clock is always 8kHz, and the MFSYNC output clock is always 2kHz. 7.2 Device Identification and Protection The 16-bit read-only ID field in the ID1 and ID2 registers is set to 0C22h = 3106 decimal. The device revision can be read from the REV register. Contact the factory to interpret this value and determine the latest revision. The register set can be protected from inadvertent writes using the PROT register. 7.3 Local Oscillator and Master Clock Configuration The T0 DPLL and the output DFS engines operate from a 204.8MHz master clock. The master clock is synthesized from a 12.800MHz clock originating from a local oscillator attached to the REFCLK pin. The stability of the T0 DPLL in free-run or holdover is equivalent to the stability of the local oscillator. Selection of an appropriate local oscillator is therefore of crucial importance if the telecom standards listed in Table 1-1 are to be met. Simple XOs can be used in less stringent cases, but TCXOs or even OCXOs may be required in the most demanding applications. Careful evaluation of the local oscillator component is necessary to ensure proper performance. Contact Maxim at www.maxim-ic.com/support for recommended oscillators. The stability of the local oscillator is very important, but its absolute frequency accuracy is less important because the DPLLs can compensate for frequency inaccuracies when synthesizing the 204.8MHz master clock from the local oscillator clock. The MCLKFREQ field in registers MCLK1 and MCLK2 specifies the frequency adjustment to be applied. The adjust can be from -771ppm to +514ppm in 0.0196229ppm (i.e., ~0.02ppm) steps. 19-4629; Rev 3; 5/09 14 of 87 ____________________________________________________________________________________________ DS3106 7.4 Input Clock Configuration The DS3106 has two input clocks: IC3 and IC4. Table 7-1 provides summary information about each clock, including signal format and available frequencies. The device tolerates a wide range of duty cycles on input clocks, out to a minimum high time or minimum low time of 3ns or 30% of the clock period, whichever is smaller. 7.4.1 Signal Format Configuration Both IC3 and IC4 accept TTL and 3.3V CMOS levels. One key configuration bit that affects the available frequencies is the SONSDH bit in MCR3. When SONSDH = 1 (SONET mode), the 1.544MHz frequency is available. When SONSDH = 0 (SDH mode), the 2.048MHz frequency is available. During reset the default value of this bit is latched from the SONSDH pin. Table 7-1. Input Clock Capabilities SIGNAL FORMATS CMOS/TTL CMOS/TTL INPUT CLOCK IC3 IC4 FREQUENCIES (MHz) Up to 125(1) Up to 125(1) DEFAULT FREQUENCY Determined by IPF[2:0] and SONSDH pins, see Table 7-2. Determined by IPF[2:0] and SONSDH pins, see Table 7-2. Note 1: Available frequencies for CMOS/TTL input clocks are: 2kHz, 4kHz, 8kHz, 1.544MHz (SONET mode), 2.048MHz (SDH mode), 6.312MHz, 6.48MHz, 19.44MHz, 25.0MHz, 25.92MHz, 38.88MHz, 51.84MHz, 62.5MHz, 77.76MHz, and any multiple of 2kHz up to 125MHz. Table 7-2. Input Clock Default Frequency Configuration IPF[2:0] SONSDH 000 001 001 010 011 100 101 110 111 X 0 1 X X X X X X DEFAULT FREQUENCY, LOCK MODE 8kHz, direct lock 2.048MHz, direct lock 1.544MHz, direct lock 6.48MHz, direct lock 19.44MHz, direct lock 25.92MHz, direct lock 38.88MHz, direct lock 51.84MHz, direct lock 77.76MHz, direct lock 7.4.2 Frequency Configuration Input clock frequencies are configured in the FREQ field of the ICR registers. The DIVN and LOCK8K bits of these same registers specify the locking frequency mode, as shown in Table 7-3. 3 Table 7-3. Locking Frequency Modes DIVN LOCK8K 0 0 1 1 0 1 0 1 19-4629; Rev 3; 5/09 LOCKING FREQUENCY MODE Direct Lock LOCK8K DIVN Alternate Direct Lock 15 of 87 ____________________________________________________________________________________________ DS3106 7.4.2.1 Direct Lock Mode In direct lock mode, the T0 DPLL locks to the selected reference at the frequency specified in the corresponding ICR register. Direct lock mode can only be used for input clocks with these specific frequencies: 2kHz, 4kHz, 8kHz, 1.544MHz, 2.048MHz, 5MHz, 6.312MHz, 6.48MHz, 19.44MHz, 25.92MHz, 31.25MHz, 38.88MHz, 51.84MHz, and 77.76MHz. The DIVN mode can be used to divide an input down to any of these frequencies except 155.52MHz. 13 MTIE figures may be marginally better in direct lock mode because the higher frequencies allow more frequent phase updates. 7.4.2.2 Alternate Direct Lock Mode Alternate direct lock mode is the same as direct lock mode except an alternate list of direct lock frequencies is used (see the FREQ field definition in the ICR register description). The alternate frequencies are included to support clock rates found in Ethernet, CMTS, wireless, and GPS applications. The alternate frequencies are: 10MHz, 25MHz, 62.5MHz, and 125MHz. The frequencies 62.5MHz and 125MHz are internally divided down to 31.25MHz, while 10MHz and 25MHz are internally divided down to 5MHz. 13 7.4.2.3 LOCK8K Mode In LOCK8K mode, an internal divider is configured to divide the selected reference down to 8kHz. The DPLL locks to the 8kHz output of the divider. LOCK8K mode can only be used for input clocks with the standard direct lock frequencies: 8kHz, 1.544MHz, 2.048MHz, 5MHz, 6.312MHz, 6.48MHz, 19.44MHz, 25.0MHz, 25.92MHz, 31.25MHz, 38.88MHz, 51.84MHz, 62.5MHz, and 77.76MHz. LOCK8K mode is enabled for a particular input clock by setting the LOCK8K bit in the corresponding ICR register. 13 LOCK8K mode gives a greater tolerance to input jitter when the multicycle phase detector is disabled because it uses lower frequencies for phase comparisons. The clock edge to lock to on the selected reference can be configured using the 8KPOL bit in the TEST1 register. For 2kHz and 4kHz clocks the LOCK8K bit is ignored and direct-lock mode is used. 7.4.2.4 DIVN Mode In DIVN mode, an internal divider is configured from the value stored in the DIVN registers. The DIVN value must be chosen so that when the selected reference is divided by DIVN+1, the resulting clock frequency is the same as the standard direct lock frequency selected in the FREQ field of the ICR register. The DPLL locks to the output of the divider. DIVN mode can only be used for input clocks whose frequency is less than or equal to 125MHz. The DIVN register field can range from 0 to 65,535 inclusive. The same DIVN+1 factor is used for all input clocks configured for DIVN mode. 13 7.5 Input Clock Monitoring Each input clock is continuously monitored for activity. Activity monitoring is described in Sections 7.5.2 and 7.5.3. The valid/invalid state of each input clock is reported in the corresponding real-time status bit in register VALSR1. When the valid/invalid state of a clock changes, the corresponding latched status bit is set in register MSR1, and an interrupt request occurs if the corresponding interrupt enable bit is set in register IER1. Input clocks marked invalid cannot be automatically selected as the reference for either DPLL. 7.5.1 Frequency Monitoring The DS3106 monitors the frequency of each input clock and invalidates any clock whose frequency is more than 10,000ppm away from nominal. The frequency range monitor can be disabled by clearing the MCR1.FREN bit. The frequency range measurement uses the internal 204.8MHz master clock as the frequency reference. 7.5.2 Activity Monitoring Each input clock is monitored for activity and proper behavior using a leaky bucket accumulator. A leaky bucket accumulator is similar to an analog integrator: the output amplitude increases in the presence of input events and gradually decays in the absence of events. When events occur infrequently, the accumulator value decays fully 19-4629; Rev 3; 5/09 16 of 87 ____________________________________________________________________________________________ DS3106 between events and no alarm is declared. When events occur close enough together, the accumulator increments faster than it can decay and eventually reaches the alarm threshold. After an alarm has been declared, if events occur infrequently enough, the accumulator can decay faster than it is incremented and eventually reaches the alarm clear threshold. The leaky bucket events come from the frequency range and fast activity monitors. There is one leaky bucket configuration common to both inputs that has programmable size, alarm declare threshold, alarm clear threshold, and decay rate, all of which are specified in the LB0x registers. Activity monitoring is divided into 128ms intervals. The accumulator is incremented once for each 128ms interval in which the input clock is inactive for more than two cycles (more than four cycles for 125MHz, 62.5MHz, 25MHz, and 10MHz input clocks). Thus, the “fill” rate of the bucket is at most 1 unit per 128ms, or approximately 8 units/second. During each period of 1, 2, 4, or 8 intervals (programmable), the accumulator decrements if no irregularities occur. Thus, the “leak” rate of the bucket is approximately 8, 4, 2, or 1 units/second. A leak is prevented when a fill event occurs in the same interval. When the value of an accumulator reaches the alarm threshold (LB0U register), the corresponding ACT alarm bit is set to 1 in the ISR2 register, and the clock is marked invalid in the VALSR1 register. When the value of an accumulator reaches the alarm clear threshold (LB0L register), the activity alarm is cleared by clearing the clock’s ACT bit. The accumulator cannot increment past the size of the bucket specified in the LB0S register. The decay rate of the accumulator is specified in the LB0D register. The values stored in the leaky bucket configuration registers must have the following relationship at all times: LB0S ≥ LB0U > LB0L. 3 3 3 13 3 3 13 13 When the leaky bucket is empty, the minimum time to declare an activity alarm in seconds is LB0U / 8. The minimum time to clear an activity alarm in seconds is 2^LB0D (LB0S – LB0L) / 8. As an example, assume LB0U = 8, LB0L = 1, LB0S = 10, and LB0D = 0. The minimum time to declare an activity alarm would be 8 / 8 = 1 second. The minimum time to clear the activity alarm would be 2^0 (10 – 1) / 8 = 1.125 seconds. 7.5.3 Selected Reference Activity Monitoring The input clock that T0 DPLL is currently locked to is called the selected reference. The quality of a DPLL’s selected reference is exceedingly important, since missing cycles and other anomalies on the selected reference can cause unwanted jitter, wander, or frequency offset on the output clocks. When anomalies occur on the selected reference, they must be detected as soon as possible to give the DPLL opportunity to temporarily disconnect from the reference until the reference is available again. By design, the regular input clock activity monitor (Section 7.5.2) is too slow to be suitable for monitoring the selected reference. Instead, each DPLL has its own fast activity monitor that detects that the frequency is within range (approximately 10,000ppm) and detects inactivity within approximately two missing reference clock cycles (approximately four missing cycles for 125MHz, 62.5MHz, 25MHz, and 10MHz references). When the T0 DPLL detects a no-activity event, it immediately enters mini-holdover mode to isolate itself from the selected reference and sets the SRFAIL latched status bit in MSR2. The setting of the SRFAIL bit can cause an interrupt request if the corresponding enable bit is set in IER2. If MCR10:SRFPIN = 1, the SRFAIL output pin follows the state of the SRFAIL status bit. When PHLIM1:NALOL = 0 (default), the T0 DPLL does not declare lossof-lock during no-activity events. If the selected reference becomes available again before any alarms are declared by the activity monitor, the T0 DPLL continues to track the selected reference using nearest edge locking (180) to avoid cycle slips. When NALOL = 1, the T0 DPLL declares loss-of-lock during no-activity events. This causes the T0 DPLL state machine to transition to the loss-of-lock state, which sets the MSR2:STATE bit and causes an interrupt request if enabled. If the selected reference becomes available again before any alarms are declared by the activity monitor, the T0 DPLL tracks the selected reference using phase/frequency locking (360) until phase lock is reestablished. 7.6 Input Clock Priority and Switching The SRCSW input pin controls reference switching between two clock inputs. In this mode, if the SRCSW pin is high, the T0 DPLL is forced to lock to input IC3. If the SRCSW pin is low the device is forced to lock to input IC4. The currently selected reference is indicated in the PTAB1:SELREF field. 19-4629; Rev 3; 5/09 17 of 87 ____________________________________________________________________________________________ DS3106 7.7 DPLL Architecture and Configuration The T0 DPLL is a digital PLL with separate analog PLLs (APLLs) as output stages as well as some outputs that are not cleaned up by an APLL. This architecture combines the benefits of both PLL types. See Figure 7-1. Figure 7-1. DPLL Block Diagram 2K8K DFS DIG12 DFS 2 2K8K DIG1 MCR6:DIG1SS MCR6:DIG1F[1:0] DIG12 DFS DIG2 MCR6:DIG2SS MCR6:DIG2F[1:0] MCR6:DIG2AF T0 selected reference T0 PFD and Loop Filter Locking Frequency T0 Foward DFS T0 Feedback DFS ICRn:FREQ[3:0] T0 DPLL T4 APLL DFS APLL Output Dividers OCRm:OFREQn[3:0] OCR5:AOFn T4CR1:T4FREQ[3:0] T0CR1:T0FT4[2:0] T0 Output APLL APLL Output Dividers T0 APLL2 DFS T0 Output APLL2 APLL Output Dividers FSYNC DFS 2 T0 APLL DFS T0CR1:T0FREQ[2:0] OUTPUT DFS 19-4629; Rev 3; 5/09 OC3, OC6 T4 Output APLL FSYNC, MFSYNC OCR4:FSEN, MFSEN FSCR1:8KINV, 2KINV FSCR1:8KPOL, 2KPOL 18 of 87 ____________________________________________________________________________________________ DS3106 Digital PLLs have two key benefits: (1) stable, repeatable performance that is insensitive to process variations, temperature, and voltage; and (2) flexible behavior that is easily programmed through the configuration registers. DPLLs use digital frequency synthesis (DFS) to generate various clocks. In DFS a high-speed master clock (204.8MHz) is multiplied up from the 12.800MHz local oscillator clock applied to the REFCLK pin. This master clock is then digitally divided down to the desired output frequency. The DFS output clock has jitter of about 1ns pkpk. The analog PLLs filter the jitter from the DPLLs, reducing the 1ns pk-pk jitter to less than 0.5ns pk-pk and 60ps RMS, typical, measured broadband (10Hz to 1GHz). The DPLLs in the device are configurable for many PLL parameters including bandwidth, damping factor, input frequency, pull-in/hold-in range, and more. No knowledge of loop equations or gain parameters is required to configure and operate the device. No external components are required for the DPLL or the APLLs except the high-quality local oscillator connected to the REFCLK pin. The T0 DPLL has a full free-run/locked/holdover state machine and full programmability. 7.7.1 T0 DPLL State Machine The T0 DPLL has three main timing modes: locked, holdover, and free-run. The control state machine for the T0 DPLL has states for each timing mode as well as three temporary states: prelocked, prelocked 2, and loss-of-lock. The state transition diagram is shown in Figure 7-2. Descriptions of each state are given in the paragraphs below. During normal operation the state machine controls state transitions. When necessary, however, the state can be forced using the T0STATE field of the MCR1 register. Whenever the T0 DPLL changes state, the STATE bit in MSR2 is set, which can cause an interrupt request if enabled. The current T0 DPLL state can be read from the T0STATE field of the OPSTATE register. 7.7.1.1 Free-Run State Free-run mode is the reset default state. In free-run all output clocks are derived from the 12.800 MHz local oscillator attached to the REFCLK pin. The frequency of each output clock is a specific multiple of the local oscillator. The frequency accuracy of each output clock is equal to the frequency accuracy of the master clock, which can be calibrated using the MCLKFREQ field in registers MCLK1 and MCLK2 (see Section 7.3). The state machine transitions from free-run to the prelocked state when at least one input clock is valid. 7.7.1.2 Prelocked State If phase lock (see Section 7.7.5) is achieved for 2 seconds during this period, the state machine transitions to locked mode. If the selected reference becomes inactive for 2 seconds then the state machine transitions back to the free-run state. 19-4629; Rev 3; 5/09 19 of 87 ____________________________________________________________________________________________ DS3106 Figure 7-2. T0 DPLL State Transition Diagram FREE-RUN (001) RESET SELECTED REFERENCE INACTIVE > 2s SELECTED REFERENCE ACTIVE PRE-LOCKED (110) PHASE-LOCKED TO SELECTED REFERENCE > 2s SELECTED REFERENCE SWITCH LOCKED (100) SELECTED REFERENCE INACTIVE > 2s SELECTED REFERENCE PHASE-LOCKED > 2s PHASE-LOCK REGAINED ON SELECTED REFERENCE > 2s PRE-LOCKED 2 (101) SELECTED REFERENCE SWITCH LOSS-OF-LOCK ON SELECTED REFERENCE LOSS-OFLOCK (111) SELECTED REFERENCE INACTIVE > 2s HOLDOVER (010) SELECTED REFERENCE INACTIVE > 2s SELECTED REFERENCE ACTIVE Note 1: Phase lock is declared internally when the DPLL has maintained phase lock continuously for approximately 1 to 2 seconds. Note 2: When selected reference is invalid and the DPLL is not in free-run or holdover, the DPLL is in a temporary holdover state. 19-4629; Rev 3; 5/09 20 of 87 ____________________________________________________________________________________________ DS3106 7.7.1.3 Locked State The T0 DPLL state machine can reach the locked state from the prelocked, prelocked 2, or loss-of-lock states when the DPLL has locked to the selected reference for at least 2 seconds (see Section 7.7.5). In the locked state the output clocks track the phase and frequency of the selected reference. If the MCR1.LOCKPIN bit is set, the LOCK pin is driven high when the T0 DPLL is in the locked state. While in the locked state, if the selected reference becomes inactive and an activity alarm is raised (corresponding ACT bit set in the ISR2 register), the selected reference is marked invalid (ICn bit goes low in the VALSR1 register), and the LOS pin is asserted. If the input stays inactive for 2 seconds, the state machine transitions to the holdover state. If the DPLL is switched to the other input and that input is active, the state machine transitions to the prelocked 2 state. 4 7.7.1.4 Loss-of-Lock State When the loss-of-lock detectors (see Section 7.7.5) indicate loss-of-phase lock, the state machine immediately transitions from the locked state to the loss-of-lock state. If phase lock is regained during that period for more than 2 seconds while in the loss-of-lock state, the state machine transitions back to the locked state. While in the loss-of-lock state, if the selected reference is becomes inactive, an activity alarm is raised (corresponding ACT bit set in the ISR2 register), the selected reference is marked invalid (ICn bit goes low in the VALSR1 register), and the LOS pin is asserted. If the input stays inactive for 2 seconds, the state machine transitions to the holdover state. If the DPLL is switched to the other input and that input is active, the state machine transitions to the prelocked 2 state. 14 4 7.7.1.5 Prelocked 2 State The prelocked and prelocked 2 states are similar. If phase lock (see Section 7.7.5) is achieved for more than 2 seconds, the state machine transitions to locked mode. While in the prelocked 2 state, if the selected reference is becomes inactive, an activity alarm is raised (corresponding ACT bit set in the ISR2 register), the selected reference is marked invalid (ICn bit goes low in the VALSR1 register), and the LOS pin is asserted. If the input stays inactive for 2 seconds, the state machine transitions to the holdover state. 14 4 7.7.1.6 Holdover State The device reaches the holdover state when it declares its selected reference invalid for 2 seconds. During holdover the T0 DPLL is not phase-locked to any input clock but instead generates its output frequency based on previous frequencies while it was locked. When the selected reference becomes active, the state machine immediately transitions from holdover to the prelocked 2 state, and tries to lock to the selected reference. 7.7.1.6.1Automatic Holdover For automatic holdover (FRUNHO = 0 in MCR3), the device can be further configured for instantaneous mode or averaged mode. In instantaneous mode (AVG = 0 in HOCR3), the holdover frequency is set to the DPLL’s current frequency 50ms to 100ms before entry into holdover (i.e., the value of the FREQ field in the FREQ1, FREQ2, and FREQ3 registers). The FREQ field is the DPLL’s integral path and, therefore, is an average frequency with a rate of change inversely proportional to the DPLL bandwidth. The DPLL’s proportional path is not used in order to minimize the effect of recent phase disturbances on the holdover frequency. In averaged mode (AVG = 1 in HOCR3 and FRUNHO = 1 in MCR3), the holdover frequency is set to an internally averaged value. During locked operation the frequency indicated in the FREQ field is internally averaged over a one-second period. The T0 DPLL indicates that it has acquired a valid holdover value by setting the HORDY status bit in MSR4 (latched status). If the T0 DPLL must enter holdover before the one-second average is available, an instantaneous value 50ms to 100ms old from the integral path is used instead. 7.7.1.6.2Free-Run Holdover For free-run holdover (FRUNHO = 1 in MCR3), the output frequency accuracy is generated with the accuracy of the external oscillator frequency. The actual frequency is the frequency of the external oscillator plus the value of the MCLK offset specified in the MCLKFREQ field in registers MCLK1 and MCLK2 (see Section 7.3). When MCR3.FRUNHO is set the HOCR3:AVG bit is ignored. 19-4629; Rev 3; 5/09 21 of 87 ____________________________________________________________________________________________ DS3106 7.7.1.7 Mini-Holdover When the selected reference fails, the fast activity monitor (Section 7.5.3) isolates the T0 DPLL from the reference within one or two clock cycles to avoid adverse effects on the DPLL frequency. When this fast isolation occurs, the DPLL enters a temporary mini-holdover mode, with a frequency equal to an instantaneous value 50ms to 100 ms old from the integral path of the loop filter. Mini-holdover lasts until the selected reference becomes active or the state machine enters the holdover state. If the free-run holdover mode is set (FRUNHO = 1 in MCR3), the miniholdover frequency accuracy is exactly the same as the external oscillator accuracy plus the offset set by the MCLKFREQ field in registers MCLK1 and MCLK2 (see Section 7.3). 7.7.2 Bandwidth The bandwidth of the T0 DPLL is configured in the T0ABW and T0LBW registers for various values from 18Hz to 400Hz. The AUTOBW bit in the MCR9 register controls automatic bandwidth selection. When AUTOBW = 1, the T0 DPLL uses the T0ABW bandwidth during acquisition (not phase-locked) and the T0LBW bandwidth when phase-locked. When AUTOBW = 0 the T0 DPLL uses the T0LBW bandwidth all the time, both during acquisition and when phase-locked. When LIMINT = 1 in the MCR9 register, the DPLL’s integral path is limited (i.e., frozen) when the DPLL reaches minimum or maximum frequency. Setting LIMINT = 1 minimizes overshoot when the DPLL is pulling in. 7.7.3 Damping Factor The damping factor for the T0 DPLL is configured in the DAMP field of the T0CR2 register. The reset default damping factor is chosen to give a maximum jitter/wander gain peak of approximately 0.1dB. Available settings are a function of DPLL bandwidth (configured in the T0ABW and T0LBW registers). See Table 7-4. Table 7-4. Damping Factors and Peak Jitter/Wander Gain BANDWIDTH (Hz) 18 35 70 to 400 DAMP[2:0] VALUE DAMPING FACTOR GAIN PEAK (dB) 1 2 3, 4, 5 1 2 3 4, 5 1 2 3 4 5 1.2 2.5 5 1.2 2.5 5 10 1.2 2.5 5 10 20 0.4 0.2 0.1 0.4 0.2 0.1 0.06 0.4 0.2 0.1 0.06 0.03 7.7.4 Phase Detectors Phase detectors are used to compare a PLL’s feedback clock with its input clock. Several phase detectors are available in the T0 DPLL: Phase/frequency detector (PFD) Early/late phase detector (PD2) for fine resolution Multicycle phase detector (MCPD) for large input jitter tolerance and/or faster lock times These detectors can be used in combination to give fine phase resolution combined with large jitter tolerance. As with the rest of the DPLL logic, the phase detectors operate at input frequencies up to 77.76MHz. The multicycle phase detector detects and remembers phase differences of many cycles (up to 8191UI). When locking to 8kHz or lower, the normal phase/frequency detectors are always used. 19-4629; Rev 3; 5/09 22 of 87 ____________________________________________________________________________________________ DS3106 The T0 DPLL phase detectors can be configured for normal phase/frequency locking (360 capture) or nearest edge phase locking (180 capture). With nearest edge detection the phase detectors are immune to occasional missing clock cycles. The DPLL automatically switches to nearest edge locking when the multicycle phase detector is disabled and the other phase detectors determine that phase lock has been achieved. Setting D180 = 1 in the TEST1 register disables nearest edge locking and forces the T0 DPLL to use phase/frequency locking. The early/late phase detector, also known as phase detector 2, is enabled and configured in the PD2 fields of the T0CR2 register. The reset default settings of this register is appropriate for all operating modes. Adjustments only affect small signal overshoot and bandwidth. The multicycle phase detector is enabled by setting MCPDEN = 1 in the PHLIM2 register. The range of the MCPD—from 1UI up to 8191UI—is configured in the COARSELIM field of PHLIM2. The MCPD tracks phase position over many clock cycles, giving high jitter tolerance. Thus, the use of the MCPD is an alternative to the use of LOCK8K mode for jitter tolerance. When a DPLL is direct locking to 8kHz, 4kHz, or 2kHz, or in LOCK8K mode, the multicycle phase detector is automatically disabled. When USEMCPD = 1 in PHLIM2, the MCPD is used in the DPLL loop, giving faster pull-in but more overshoot. In this mode the loop has similar behavior to LOCK8K mode. In both cases large phase differences contribute to the dynamics of the loop. When enabled by MCPDEN = 1, the MCPD tracks the phase position whether or not it is used in the DPLL loop. When the input clock is divided before being sent to the phase detector, the divider output clock edge gets aligned to the feedback clock edge before the DPLL starts to lock to a new input clock signal or after the input clock signal has a temporary signal loss. This helps ensure locking to the nearest input clock edge, which reduces output transients and decreases lock times. 7.7.5 Loss-of-Lock Detection Loss-of-lock can be triggered by any of the following in the T0 DPLL: The fine phase-lock detector (measures phase between input and feedback clocks) The coarse phase-lock detector (measures whole cycle slips) Hard frequency limit detector Inactivity detector The fine phase-lock detector is enabled by setting FLEN = 1 in the PHLIM1 register. The fine phase limit is configured in the FINELIM field of PHLIM1. The coarse phase-lock detector is enabled by setting CLEN = 1 in the PHLIM2 register. The coarse phase limit is configured in the COARSELIM field of PHLIM2. This coarse phase-lock detector is part of the multicycle phase detector (MCPD) described in Section 7.7.4. The COARSELIM field sets both the MCPD range and the coarse phase limit, since the two are equivalent. If loss-of-lock should not be declared for multiple-UI input jitter, the fine phase-lock detector should be disabled and the coarse phase-lock detector should be used instead. The hard frequency limit detector is enabled by setting FLLOL = 1 in the DLIMIT3 register. The hard limit is configured in registers DLIMIT1 and DLIMIT2. When the DPLL frequency reaches the hard limit, loss-of-lock is declared. The DLIMIT3 register also has the SOFTLIM field to specify a soft frequency limit. Exceeding the soft frequency limit does not cause loss-of-lock to be declared. When the T0 DPLL frequency reaches the soft limit, the T0SOFT status bit is set in the OPSTATE register. Both the SOFT and HARD alarm limits have hysteresis as required by GR-1244. The inactivity detector is enabled by setting NALOL = 1 in the PHLIM1 register. When this detector is enabled the DPLL declares loss-of-lock after one or two missing clock cycles on the selected reference. See Section 7.5.3. When the T0 DPLL declares loss-of-lock, the state machine immediately transitions to the loss-of-lock state, which sets the STATE bit in the MSR2 register and requests an interrupt if enabled. 19-4629; Rev 3; 5/09 23 of 87 ____________________________________________________________________________________________ DS3106 7.7.6 Frequency and Phase Measurement Accurate measurement of frequency and phase can be accomplished using the T0 DPLL. The REFCLK signal accuracy after being adjusted with MCLKFREQ is used for the frequency reference. DPLL frequency measurements can be read from the FREQ field spanning registers FREQ1, FREQ2, and FREQ3. This field indicates the frequency of the selected reference. This frequency measurement has a resolution of 0.0003068ppm over a 80ppm range. The value read from the FREQ field is the DPLL’s integral path value, which is an averaged measurement with an averaging time inversely proportional to DPLL bandwidth. DPLL phase measurements can be read from the PHASE field spanning registers PHASE1 and PHASE2. This field indicates the phase difference seen by the phase detector. This phase measurement has a resolution of approximately 0.703 degrees and is internally averaged with a -3dB attenuation point of approximately 100Hz. Thus, for low DPLL bandwidths the PHASE field gives input phase wander in the frequency band from the DPLL corner frequency up to 100Hz. This information could be used by software to compute a crude MTIE measurement. 7.7.7 Input Jitter Tolerance The device is compliant with the jitter tolerance requirements of the standards listed in Table 1-1. When using the 360/180 PFD, jitter can be tolerated up to the point of eye closure. Either LOCK8K mode (see Section 7.4.2.2) or the multicycle phase detector (see Section 7.7.4) should be used for high jitter tolerance. 7.7.8 Jitter Transfer The transfer of jitter from the selected reference to the output clocks has a programmable transfer function that is determined by the DPLL bandwidth. (See Section 7.7.2.) In the T0 DPLL, the 3dB corner frequency of the jitter transfer function can be set to any of 7 positions from 18Hz to 400Hz. 7.7.9 Output Jitter and Wander Several factors contribute to jitter and wander on the output clocks, including: Jitter and wander amplitude on the selected reference (while in the locked state) The jitter transfer characteristic of the device (while in the locked state) The jitter and wander on the local oscillator clock signal (especially wander while in the holdover state) The DPLL in the device has programmable bandwidth (see Section 7.7.2). With respect to jitter, the DPLL behaves as a lowpass filter with a programmable pole. The bandwidth of the DPLL is low enough to strongly attenuate jitter 7.8 Output Clock Configuration A total of four output clock pins, OC3, OC6, FSYNC, and MFSYNC, are available on the device. Output clocks OC3 and OC6 are individually configurable for a variety of frequencies. Output clocks FSYNC and MFSYNC are more specialized, serving as an 8kHz frame sync (FSYNC) and a 2kHz multiframe sync (MFSYNC). Table 7-5 provides more detail on the capabilities of the output clock pins. Table 7-5. Output Clock Capabilities OUTPUT CLOCK OC3 SIGNAL FORMAT CMOS/TTL OC6 LVDS/LVPECL FSYNC MFSYNC CMOS/TTL 19-4629; Rev 3; 5/09 FREQUENCIES SUPPORTED Frequency selection per Section 7.8.2.3 and Table 7-6 to Table 7-12. 8kHz frame sync with programmable pulse width and polarity. 2kHz multiframe sync with programmable pulse width and polarity. 24 of 87 ____________________________________________________________________________________________ DS3106 7.8.1 Signal Format Configuration Output clock OC6 is an LVDS-compatible, LVPECL level-compatible outputs. The type of output can be selected or the output can be disabled using the OC6SF configuration bits in the MCR8 register. The LVPECL level-compatible mode generates a differential signal that is large enough for most LVPECL receivers. Some LVPECL receivers have a limited common-mode signal range that can be accommodated for by using an AC-coupled signal. The LVDS electrical specifications are listed in Table 10-4, and the recommended LVDS termination is shown in Figure 10-1. The LVPECL level-compatible electrical specifications are listed in Table 10-5, and the recommended LVPECL receiver termination is shown in Figure 10-2. These differential outputs can be easily interfaced to LVDS, LVPECL, and CML inputs on neighboring ICs using a few external passive components. See Maxim App Note HFAN-1.0 for details. Output clocks OC3, FSYNC, and MFSYNC are CMOS/TTL signal format. 7.8.2 Frequency Configuration The frequency of output clocks OC3 and OC6 is a function of the settings used to configure the components of the T0 PLL paths. These components are shown in the detailed block diagram of Figure 7-1. The DS3106 uses digital frequency synthesis (DFS) to generate various clocks. In DFS a high-speed master clock (204.8MHz) is divided down to the desired output frequency by adding a number to an accumulator. The DFS output is a coding of the clock output phase that is used by a special circuit to determine where to put the edges of the output clock between the clock edges of the master clock. The edges of the output clock, however, are not ideally located in time, resulting in jitter with an amplitude typically less than 1ns pk-pk. 7.8.2.1 T0 DPLL and Feedback DFS Details See Figure 7-1. The T0 forward-DFS block uses the 204.8MHz master clock and DFS technology to synthesize internal clocks from which the output and feedback clocks are derived. The feedback DFS block synthesizes the appropriate locking frequencies for use by the phase-frequency detector (PFD). See Section 7.4.2. 7.8.2.2 Output DFS and APLL Details See Figure 7-1. The output clock frequencies are determined by two 2kHz/8kHz DFS blocks, two DIG12 DFS blocks, and three APLL DFS blocks. The T0 APLL, the T0 APLL2, and the T4 APLL (and their output dividers) get their frequency references from three associated APLL DFS blocks. All the output DFS blocks are connected to the T0 DPLL. The 2K8K DFS and FSYNC DFS blocks generate both 2kHz and 8kHz signals, which have about 1ns pk-pk jitter. The FSYNC (8kHz) and MFSYNC (2 kHz) signals come from the FSYNC DFS block. The 2kHz and 8 kHz signals that can be output on OC3 or OC6 always come from the 2K8K DFS. The DIG1 DFS can generate an N x DS1 or N x E1 signal with about 1ns pk-pk jitter. The DIG2 DFS can generate an N x DS1, N x E1, 6.312MHz, 10MHz, or N x 19.44MHz clock with approximately 1ns pk-pk jitter. The frequency of the DIG1 clock is configured by the DIG1SS bit in MCR6 and the DIG1F[1:0] field in MCR7. The frequency of the DIG2 clock is configured by the DIG2AF and DIG2SS bits in MCR6 and the DIG2F[1:0] field in MCR7. DIG1 and DIG2 can be independently configured for any of the frequencies shown in Table 7-6 and Table 7-7, respectively. The APLL DFS blocks and their associated output APLLs and output dividers can generate many different frequencies. The T0 APLL frequencies that can be generated are listed in Table 7-9. The T0 APLL2 frequency is always 312.500MHz. The T4 APLL frequencies that can be generated are listed in Table 7-11. The output frequencies that can be generated from the APLL circuits are listed in Table 7-8. 19-4629; Rev 3; 5/09 25 of 87 ____________________________________________________________________________________________ DS3106 7.8.2.3 OC3 and OC6 Configuration The following is a step-by-step procedure for configuring the frequencies of output clocks OC3 and OC6: Use Table 7-8 to select a set of output frequencies for each APLL, T0 and T4. Each APLL can only generate one set of output frequencies. (In SONET/SDH equipment, the T0 APLL is typically configured for a frequency of 311.04MHz to get N x 19.44MHz output clocks to for use on line cards.) Determine from Table 7-8 the T0 and T4 APLL frequencies required for the frequency sets chosen in step 2. Configure the T0FREQ field in register T0CR1 as shown in Table 7-9 for the T0 APLL frequency determined in step 3. Configure fields T4CR1:T4FREQ, T0CR1:T4APT0, and T0CR1:T0FT4 as shown in Table 7-11 for the T4 APLL frequency determined in step 3. Using Table 7-8 and Table 7-12, configure the frequencies of output clocks OC3 and OC6 in the OFREQn fields of registers OCR2 and OCR4 and the AOFn bits in the OCR5 register. Table 7-13 lists all standard frequencies for the output clocks and specifies how to configure the T0 APLL and/or the T4 APLL to obtain each frequency. Table 7-13 also indicates the expected jitter amplitude for each frequency. Table 7-6. Digital1 Frequencies DIG1F[1:0] SETTING IN MCR7 00 01 10 11 00 01 10 11 DIG1SS SETTING IN MCR6 0 0 0 0 1 1 1 1 FREQUENCY (MHz) 2.048 4.096 8.192 16.384 1.544 3.088 6.176 12.352 JITTER (pk-pk, ns, typ) <1 <1 <1 <1 <1 <1 <1 <1 Table 7-7. Digital2 Frequencies DIG2AF SETTING IN MCR6 1 1 1 1 0 0 0 0 0 0 0 0 DIG2F[1:0] SETTING IN MCR7 00 10 00 01 00 01 10 11 00 01 10 11 19-4629; Rev 3; 5/09 DIG2SS SETTING IN MCR6 0 0 1 1 0 0 0 0 1 1 1 1 FREQUENCY (MHz) 6.312 10.000 19.440 38.880 2.048 4.096 8.192 16.384 1.544 3.088 6.176 12.352 JITTER (pk-pk, ns, typ) <1 <1 <1 <1 <1 <1 <1 <1 <1 <1 <1 <1 26 of 87 ____________________________________________________________________________________________ DS3106 Table 7-8. APLL Frequency to Output Frequencies (T0 APLL and T4 APLL) APLL FREQUENCY 312.5 311.04 274.944 250 178.944 160 148.224 131.072 122.88 104 100.992 98.816 98.304 APLL/ 2 156.25 155.52 137.472 125 89.472 80 74.112 65.536 61.44 52 50.496 49.408 49.152 APLL/ 4 — 77.76 68.376 62.5 44.736 40 37.056 32.768 30.72 26 25.248 24.704 24.576 APLL/ 5 62.5 62.208 — 50 — 32 — — 24.576 20.8 — — — APLL/ 6 — 51.84 45.824 — 29.824 — 24.704 — 20.48 — 16.832 — 16.384 APLL/ 8 — 38.88 34.368 31.25 22.368 20 18.528 16.384 15.36 13 12.624 12.352 12.288 APLL/ 10 31.25 31.104 — 25 — 16 — — 12.288 10.4 — — — APLL/ 12 — 25.92 22.912 — 14.912 — 12.352 — 10.24 — 8.416 — 8.192 APLL/ 16 — 19.44 17.184 — 11.184 10 9.264 8.192 7.68 6.5 6.312 6.176 6.144 APLL/ 20 — 15.552 — 12.5 — 8 — — 6.144 5.2 — — — APLL/ 48 — 6.48 5.728 — 3.728 — 3.088 — 2.56 — 2.104 — 2.048 APLL/ 64 — 4.86 4.296 — 2.796 2.5 2.316 2.048 1.92 — 1.578 1.544 1.536 Note: All frequencies in MHz. Common telecom, datacom, and synchronization frequencies are in bold type. Table 7-9. T0 APLL Frequency Configuration T0 APLL FREQUENCY (MHz) 311.04 311.04 98.304 131.072 148.224 98.816 100.992 250.000 T0 APLL DFS FREQUENCY (MHz) 77.76 77.76 24.576 32.768 37.056 24.704 25.248 62.500 T0 APLL FREQUENCY MODE 77.76MHz 77.76MHz 12 x E1 16 x E1 24 x DS1 16 x DS1 4 x 6312kHz GbE 16 T0FREQ[2:0] SETTING IN T0CR1 000 001 010 011 100 101 110 111 OUTPUT JITTER (pk-pk, ns, typ) < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 Table 7-10. T0 APLL2 Frequency Configuration T0 APLL2 FREQUENCY (MHz) T0 APLL2 DFS FREQUENCY(MHz) OUTPUT JITTER (pk-pk, ns, typ) 312.500 62.500 < 0.5 19-4629; Rev 3; 5/09 27 of 87 ____________________________________________________________________________________________ DS3106 Table 7-11. T4 APLL Frequency Configuration T4 APLL FREQUENCY (MHz) Disabled 311.04 98.304 131.072 148.224 98.816 274.944 178.944 100.992 250.000 122.880 160.000 104.000 98.304 250.000 131.072 148.224 98.816 100.992 T4 APLL DFS FREQUENCY (MHz) 77.76 77.76 24.576 32.768 37.056 24.704 68.736 44.736 25.248 62.500 30.720 40.000 26.000 24.576 62.500 32.768 37.056 24.704 25.248 T4 APLL FREQUENCY MODE Squelched 77.76MHz 12 x E1 16 x E1 24 x DS1 16 x DS1 2 x E3 DS3 4 x 6312kHz GbE 16 3 x 10.24 4 x 10 2 x 13 T0 12 x E1 T0 GbE 16 T0 16 x E1 T0 24 x DS1 T0 16 x DS1 T0 4 x 6312kHz T4APT0 SETTING IN T0CR1 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 T4FREQ[3:0] SETTING IN T4CR1 0000 0001 0010 0011 0100 0101 0110 0111 1000 1001 1010 1011 1100 XXXX XXXX XXXX XXXX XXXX XXXX T0FT4[2:0] SETTING IN T0CR1 XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX 000 001 010 100 110 111 OUTPUT JITTER (pk-pk, ns, typ) < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 Table 7-12. OC3 and OC6 Output Frequency Selection AOF BIT 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 FREQUENCY (1) OFREQ 0000 0001 0010 0011 0100 0101 0110 0111 1000 1001 1010 1011 1100 1101 1110 1111 0000 0001 0010 0011 0100 0101 0110 OC3 Disabled 2kHz 8kHz Digital2 Digital1 T0 / 48 T0 / 16 T0 / 12 T0 / 8 T0 / 6 T0 / 4 T4 / 64 T4 / 48 T4 / 16 T4 / 8 T4 / 4 Disabled T0 / 64 T4 / 20 T4 / 12 T4 / 10 T4 / 5 T4 / 2 OC6 Disabled 2kHz 8kHz T0 / 2 Digital1 T0 / 1 T0 / 16 T0 / 12 T0 / 8 T0 / 6 T0 / 4 T4 / 64 T4 / 48 T4 / 16 T4 / 8 T4 / 4 Disabled T4 / 5 T4 / 2 T4 / 1 T02 / 5 T02 / 2 T02 / 1 Note 1: The value of the OFREQn field (in the OCR2 and OCR3 registers) corresponding to output clock OCn. 19-4629; Rev 3; 5/09 28 of 87 ____________________________________________________________________________________________ DS3106 Table 7-13. Standard Frequencies for Programmable Outputs T0 APLL JITTER (TYP) T4 APLL FREQUENCY (MHz) OFREQn T0FREQ 2kHz 8kHz 1.536 1.544 1.544 1.578 2.048 2.048 2.048 2.104 2.316 2.500 2.560 2.796 3.088 3.088 3.728 4.096 4.296 4.860 5.200 5.728 6.144 6.144 6.176 6.176 6.312 6.312 6.480 8.000 8.192 8.192 8.192 8.416 9.264 10.000 10.000 10.240 10.400 11.184 12.288 12.288 12.352 12.352 12.352 12.500 12.624 13.000 15.360 15.552 16.000 16.384 16.384 16.384 Not OC6 from T0 APLL Not OC6 from DIG2 Not OC6 from T0 APLL Not OC6 from T0 APLL Not OC6 from DIG2 Not OC6 from T0 APLL Not OC6 from T0 APLL Not OC6 from T0 APLL Not OC6 from T0 APLL Not OC6 from DIG2 Not OC6 from T0 APLL T4FT0 T4FREQ 12 x E1 12 x E1 12 x E1 16 x DS1 4 x 6.312 16 x DS1 4 x 6.312 16 x DS1 4 x 6.312 12 x E1 16 x E1 4 x 6.312 24 x DS1 12 x E1 16 x E1 4 x 6.312 24 x DS1 12 x E1 16 x E1 4 x 6.312 24 x DS1 4 x 10 3 x 10.24 DS3 24 x DS1 24 x DS1 24 x DS1 DS3 Not OC6 from DIG2 Not OC6 from T0 APLL OC3 only 12 x E1 12 x E1 2 x E3 77.76 2 x 13 2 x E3 3 x 10.24 12 x E1 16 x DS1 16 x DS1 16 x DS1 4 x 6.312 77.76 4 x 6.312 4 x 6.312 77.76 4 x 10 16 x E1 16 x E1 24 x DS1 24 x DS1 77.76 OC3 only Not OC6 from DIG2 OC3 only Not OC6 from T0 APLL OC3 only Not OC6 from DIG2 12 x E1 16 x E1 4 x 6.312 24 x DS1 Not OC6 OC3 only OC3 only 12 x E1 12 x E1 24 x DS1 16 x DS1 16 x DS1 16 x DS1 4 x 6.312 GbE 16 4 x 6.312 GbE 16 4 x 6.312 2 x 13 3 x 10.24 77.76 4 x 10 12 x E1 16 x E1 16 x E1 16 x E1 OC3 only Not OC6 from DIG2 OC3 only OC3 only OC3 only Not OC6 from DIG2 19-4629; Rev 3; 5/09 4 x 10 3 x 10.24 3 x 10.24 DS3 12 x E1 2 x 13 2kHz 8kHz APLL/64 DIG1, DIG2 APLL/64 APLL/64 DIG1, DIG2 APLL/48 APLL/64 APLL/48 APLL/64 APLL/64 APLL/48 APLL/64 DIG1, DIG2 APLL/48 APLL/48 DIG1, DIG2 APLL/64 APLL/64 APLL/20 APLL/48 APLL/20 APLL/16 DIG1, DIG2 APLL/16 DIG2 APLL/16 APLL/48 APLL/20 DIG1, DIG2 APLL/12 APLL/16 APLL/12 APLL/16 DIG2 APLL/16 APLL/12 APLL/10 APLL/16 APLL/8 APLL/10 APLL/12 APLL/8 DIG1, DIG2 APLL/20 APLL/8 APLL/8 APLL/8 APLL/20 APLL/10 DIG1, DIG2 APLL/6 APLL/8 RMS (ps) pk-pk (ns) 100 100 100 100 75 60 100 100 70 60 60 80 90 50 100 60 50 100 70 50 90 70 90 100 100 75 100 60 60 80 100 100 70 60 60 100 80 90 90 50 100 90 60 75 100 60 60 90 90 50 80 100 100 70 1.00 1.00 1.00 1.00 0.75 0.60 1.00 1.00 0.70 0.60 0.60 0.80 0.90 0.50 1.00 0.60 0.50 1.00 0.70 0.50 0.90 0.70 0.90 1.00 1.00 075 1.00 0.60 0.6 0.80 1.00 1.00 0.70 0.60 0.60 1.00 0.80 0.90 0.90 0.50 1.00 0.90 0.60 0.75 1.00 0.60 0.60 0.90 0.90 0.50 0.80 1.00 1.00 0.70 29 of 87 ____________________________________________________________________________________________ DS3106 T0 APLL JITTER (TYP) T4 APLL FREQUENCY (MHz) OFREQn T0FREQ 16.832 17.184 18.528 19.440 19.440 20.000 20.800 22.368 24.576 24.576 24.704 24.704 25.000 25.248 25.920 26.000 30.720 31.104 31.250 31.250 32.000 32.768 34.368 37.056 38.880 40.000 44.736 49.152 49.408 50.000 50.496 51.840 52.000 61.440 62.208 62.500 62.500 65.536 68.736 74.112 77.76 80.000 89.472 98.304 98.816 100.992 104.000 122.880 125.000 131.072 137.472 148.224 155.520 156.250 160.000 178.944 250.000 T4FT0 T4FREQ 24 x DS1 2 x E3 24 x DS1 4 x 6.312 24 x DS1 OC3 only 77.76 12 x E1 24 x DS1 16 x DS1 12 x E1 77.76 4 x 10 2 x 13 DS3 12 x E1 3 x 10.24 16 x DS1 GbE 16 4 x 6.312 16 x DS1 GbE 16 4 x 6.312 GbE 16 GbE 16 2 x 13 3 x 10.24 77.76 GbE 16 16 x E1 16 x E1 24 x DS1 77.76 24 x DS1 Not OC3 from T0 APLL Not OC3 from T0 APLL 12 x E1 16 x DS1 Not OC3 from T0 APLL 4 x 6.312 77.76 12 x E1 16 x DS1 GbE 16 4 x 6.312 4 x 10 16 x E1 2 x E3 24 x DS1 77.76 4 x 10 DS3 12 x E1 16 x DS1 GbE 16 4 x 6.312 GbE 16 GbE 16 2 x 13 3 x 10.24 77.76 GbE 16 16 x E1 16 x E1 24 x DS1 77.76 24 x DS1 12 x E1 16 x DS1 4 x 6312 kHz 12 x E1 16 x DS1 4 x 6312 kHz GbE 16 16 x E1 GbE 16 16 x E1 24 x DS1 77.76 24 x DS1 OC3 only 4 x 6.312 77.76 OC3 only OC6 only from T0 APLL2 Not OC3 from T0 APLL Not OC3 from T0 APLL OC6 only OC6 only OC6 only OC6 only OC6 only Not OC3 from T0 APLL OC6 only OC6 only OC6 only Not OC3 from T0 APLL OC6 only from T0 APLL2 OC6 only OC6 only OC6 only 19-4629; Rev 3; 5/09 16 x E1 2 x E3 24 x DS1 77.76 4 x 10 DS3 12 x E1 16 x DS1 4 x 6312 kHz 2 x 13 3 x 10.24 GbE 16 16 x E1 2 x E3 24 x DS1 77.76 4 x 10 DS3 GbE 16 APLL/6 APLL/16 APLL/8 DIG2 APLL/16 APLL/8 APLL/5 APLL/8 APLL/4 APLL/5 APLL/6 APLL/4 APLL/10 APLL/4 APLL/12 APLL/4 APLL/4 APLL/10 APLL/8 APLL/10 APLL/5 APLL/4 APLL/8 APLL/4 APLL/8 APLL/4 APLL/4 APLL/2 APLL/2 APLL/5 APLL/2 APLL/6 APLL/2 APLL/2 APLL/5 APLL/4 APLL/5 APLL/2 APLL/4 APLL/2 APLL/4 APLL/2 APLL/2 APLL/1 APLL/1 APLL/1 APLL/1 APLL/1 APLL/2 APLL/1 APLL/2 APLL/1 APLL/2 APLL/2 APLL/1 APLL/1 APLL/1 RMS (ps) pk-pk (ns) 60 70 60 100 50 80 90 50 100 90 60 75 60 60 50 90 90 50 60 60 80 70 70 60 50 80 50 100 75 60 60 50 90 90 50 60 60 70 70 60 50 80 50 100 75 60 90 90 60 70 70 60 50 60 80 50 60 0.60 0.70 0.60 1.00 0.50 0.80 0.90 0.50 1.00 0.90 0.60 0.75 0.60 0.60 0.50 0.90 0.90 0.50 0.60 0.60 0.80 0.70 0.70 0.60 0.50 0.80 0.50 1.00 0.75 0.60 0.60 0.50 0.90 0.90 0.50 0.60 0.60 0.70 0.70 0.60 0.50 0.80 0.50 1.00 0.75 0.60 0.90 0.90 0.60 0.70 0.70 0.60 0.50 0.60 0.80 0.50 0.60 30 of 87 ____________________________________________________________________________________________ DS3106 T0 APLL FREQUENCY (MHz) OFREQn T0FREQ 274.944 311.040 312.500 JITTER (TYP) T4 APLL OC6 only OC6 only OC6 only from T0 APLL2 T4FT0 77.76 T4FREQ APLL/1 APLL/2 RMS (ps) pk-pk (ns) 70 50 60 0.70 0.50 0.60 7.8.2.4 OC3 and OC6 Default Frequency Select Pins There are two sets of frequency select pins, O3F[2:0] and O6F[2:0], that control the reset default frequencies of the OC3 and OC6 output clock pins, respectively. The SONSDH pin also selects the output frequencies for some of the pin settings. There is also an interaction between O3F[2:0] and O6F[2:0] when O6F[2:0] uses some internal resource that is needed to generate certain frequencies. After reset the O3F[2:0] and O6F[2:0] pins can be used as GPIO pins and status output pins. The default output frequencies are affected by changing the register bit values of four registers: OCR2, OCR3, T0CR1, and T4CR1. The register defaults can be changed after reset using the microprocessor interface. Table 7-14. T0FREQ Default Settings O6F[2:0] O3F[2:0] =001 =001 !=001 X X !=001 SONSDH 0 1 X X T0CR1.T0FREQ 010 12 x E1 DFB 100 24 x DS1 DFB 001 77.76 AFB 001 77.76 AFB Table 7-15. T4FREQ Default Settings O6F[2:0] O3F[2:0] =001 X X =010 !=001 !=010 SONSDH 0 1 0 1 0 1 T4CR1.T4FREQ 0110 E3 0111 DS3 0110 E3 0111 DS3 0011 16 x E1 0101 16 x DS1 Table 7-16. OC6 Default Frequency Configuration O6F[2:0] SONSDH FREQUENCY (MHz) OCR3. OFREQ6 APLL SRC 000 X 0 1 X X X X X X 0 68.736 22.368 19.44 25.92 38.88 51.84 77.76 155.52 0000 1111 1110 0110 0111 1000 1001 1010 0011 — T4 T4 T0 T0 T0 T0 T0 T0 001 010 011 100* 101 110 111 *Occurs when O6F[2:0] are left floating. 19-4629; Rev 3; 5/09 31 of 87 ____________________________________________________________________________________________ DS3106 Table 7-17. OC3 Default Frequency Configuration O3F[2:0] SONSDH FREQUENCY (MHz) O6F[2:0] =001 OCR2. OFREQ3 APLL SRC 000 X 0 1 0 1 0 1 X X X X X 0 8.192 6.176 8.192 12.352 68.736 22.368 19.44 25.92 38.88 51.84 77.76 X 0000 1101 1101 0111 0111 1111 1110 0110 0111 1000 1001 1010 — T4 T4 T0 T0 T4 T4 T0 T0 T0 T0 T0 001 001 001 010 010 011* 100 101 110 111 FALSE TRUE X X X X X X X *Occurs when O3F[2:0] are left floating. 7.8.2.5 FSYNC and MFSYNC Configuration The FSYNC output is enabled by setting FSEN = 1 in the OCR4 register, while the MFSYNC output is enabled by setting MFSEN = 1 in OCR4. When disabled, these pins are driven low. When 8KPUL = 0 in FSCR1, FSYNC is configured as an 8kHz clock with 50% duty cycle. When 8KPUL = 1, FSYNC is an 8kHz frame sync that pulses low once every 125s with pulse width equal to one cycle of output clock OC3. When 8KINV = 1 in FSCR1, the clock or pulse polarity of FSYNC is inverted. When 2KPUL = 0 in FSCR1, MFSYNC is configured as an 2kHz clock with 50% duty cycle. When 2KPUL = 1, MFSYNC is a 2kHz frame sync that pulses low once every 500s with pulse width equal to one cycle of output clock OC3. When 2KINV = 1 in FSCR1, the clock or pulse polarity f MFSYNC is inverted. If either 8KPUL = 1 or 2KPUL = 1, output clock OC3 must be generated from the T0 DPLL and must be configured for a frequency of 1.544MHz or higher or the FSYNC/MFSYNC pulses may not be generated correctly. Figure 7-3 shows how the 8KPUL and 8KINV control bits affect the FSYNC output. The 2KPUL and 2KINV bits have an identical effect on MFSYNC. Figure 7-3. FSYNC 8kHz Options OC3 OUTPUT CLOCK FSYNC, 8KPUL=0, 8KINV=0 FSYNC, 8KPUL=0, 8KINV=1 FSYNC, 8KPUL=1, 8KINV=0 FSYNC, 8KPUL=1, 8KINV=1 7.8.2.6 Custom Output Frequencies In addition to the many standard frequencies available in the device, any of the seven output DFS blocks can be configured to generate a custom frequency. Possible custom frequencies include any multiple of 2kHz up to 19-4629; Rev 3; 5/09 32 of 87 ____________________________________________________________________________________________ DS3106 77.76MHz, any multiple of 8kHz up to 311.04MHz, and any multiple of 10kHz up to 388.79MHz. (An APLL must be used to achieve frequencies above 77.76MHz.) Any of the programmable output clocks can be configured to output the custom frequency or submultiples thereof. Contact the factory at www.maxim-ic.com/support for help with custom frequencies. 7.9 Microprocessor Interface The DS3106 presents an SPI interface on the CS, SCLK, SDI, and SDO pins. SPI is a widely used master/slave bus protocol that allows a master device and one or more slave devices to communicate over a serial bus. The DS3106 is always a slave device. Masters are typically microprocessors, ASICs, or FPGAs. Data transfers are always initiated by the master device, which also generates the SCLK signal. The DS3106 receives serial data on the SDI pin and transmits serial data on the SDO pin. SDO is high impedance except when the DS3106 is transmitting data to the bus master. Bit Order. When both bit 3 and bit 4 are low at device address 3FFFh, the register address and all data bytes are transmitted MSB first on both SDI and SDO. When either bit 3 or bit 4 is set to 1 at device address 3FFFh, the register address and all data bytes are transmitted LSB first on both SDI and SDO. The reset default setting and Motorola SPI convention is MSB first. Clock Polarity and Phase. SCLK is normally low and pulses high during bus transactions. The CPHA pin sets the phase (active edge) of SCLK. When CPHA = 0, data is latched in on SDI on the leading edge of the SCLK pulse and updated on SDO on the trailing edge. When CPHA = 1, data is latched in on SDI on the trailing edge of the SCLK pulse and updated on SDO on the following leading edge. SCLK does not have to toggle between accesses, i.e., when CS is high. See Figure 7-4. Device Selection. Each SPI device has its own chip-select line. To select the DS3106, pull its CS pin low. Control Word. After CS is pulled low, the bus master transmits the control word during the first 16 SCLK cycles. In MSB-first mode the control word has the form: R/W A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0 BURST where A[13:0] is the register address, R/W is the data direction bit (1 = read, 0 = write), and BURST is the burst bit (1 = burst access, 0 = single-byte access). In LSB-first mode the order of the 14 address bits is reversed. In the discussion that follows, a control word with R/W = 1 is a read control word, while a control word with R/W = 0 is a write control word. Single-Byte Writes. See Figure 7-5. After CS goes low, the bus master transmits a write control word with BURST = 0, followed by the data byte to be written. The bus master then terminates the transaction by pulling CS high. Single-Byte Reads. See Figure 7-5. After CS goes low, the bus master transmits a read control word with BURST = 0. The DS3106 then responds with the requested data byte. The bus master then terminates the transaction by pulling CS high. Burst Writes. See Figure 7-5. After CS goes low, the bus master transmits a write control word with BURST = 1 followed by the first data byte to be written. The DS3106 receives the first data byte on SDI, writes it to the specified register, increments its internal address register, and prepares to receive the next data byte. If the master continues to transmit, the DS3106 continues to write the data received and increment its address counter. After the address counter reaches 3FFFh it rolls over to address 0000h and continues to increment. Burst Reads. See Figure 7-5. After CS goes low, the bus master transmits a read control word with BURST = 1. The DS3106 then responds with the requested data byte on SDO, increments its address counter, and prefetches the next data byte. If the bus master continues to demand data, the DS3106 continues to provide the data on SDO, increment its address counter, and prefetch the following byte. After the address counter reaches 3FFFh, it rolls over to address 0000h and continues to increment. 19-4629; Rev 3; 5/09 33 of 87 ____________________________________________________________________________________________ DS3106 Early Termination of Bus Transactions. The bus master can terminate SPI bus transactions at any time by pulling CS high. In response to early terminations, the DS3106 resets its SPI interface logic and waits for the start of the next transaction. If a write transaction is terminated prior to the SCLK edge that latches the LSB of a data byte, the data byte is not written. Design Option: Wiring SDI and SDO Together. Because communication between the bus master and the DS3106 is half-duplex, the SDI and SDO pins can be wired together externally to reduce wire count. To support this option, the bus master must not drive the SDI/SDO line when the DS3106 is transmitting. AC Timing. See Table 10-9 and Figure 10-3 for AC timing specifications for the SPI interface. 19-4629; Rev 3; 5/09 34 of 87 ____________________________________________________________________________________________ DS3106 Figure 7-4. SPI Clock Phase Options CS SCLK CPHA = 0 SCLK CPHA = 1 SDI/SDO MSB 6 5 4 3 2 1 LSB CLOCK EDGE USED FOR DATA CAPTURE (ALL MODES) Figure 7-5. SPI Bus Transactions Single-Byte Write CS SDI R/W Register Address Burst 0 (Write) Data Byte 0 (single-byte) SDO Single-Byte Read CS SDI R/W Register Address Burst 1 (Read) 0 (single-byte) Data Byte SDO Burst Write CS SDI R/W Register Address Burst Data Byte 1 0 (Write) Data Byte N 1 (burst) SDO Burst Read CS SDI R/W Register Address Burst 1 (Read) 1 (burst) Data Byte 1 19-4629; Rev 3; 5/09 Data Byte N 35 of 87 ____________________________________________________________________________________________ DS3106 7.10 Reset Logic The device has three reset controls: the RST pin, the RST bit in MCR1, and the JTAG reset pin JTRST. The RST pin asynchronously resets the entire device, except for the JTAG logic. When the RST pin is low all internal registers are reset to their default values, including those fields that latch their default values from, or based on, the states of configuration input pins when the RST goes high. The RST pin must be asserted once after power-up while the external oscillator is stabilizing. The MCR1:RST bit resets the entire device (except for the microprocessor interface, the JTAG logic, and the RST bit itself), but when RST is active, the register fields with pin-programmed defaults do not latch their values from, or based on, the corresponding input pins. Instead, these fields are reset to the default values that were latched when the RST pin was last active. Maxim recommends holding RST low while the external oscillator starts up and stabilizes. An incorrect reset condition could result if RST is released before the oscillator has started up completely. Important: System software must wait at least 100µs after reset (RST pin or RST bit) is deasserted before initializing the device as described in Section 7.12. 7.11 Power-Supply Considerations Due to the DS3106’s dual-power-supply nature, some I/Os have parasitic diodes between a 1.8V supply and a 3.3V supply. When ramping power supplies up or down, care must be taken to avoid forward-biasing these diodes because it could cause latchup. Two methods are available to prevent this. The first method is to place a Schottky diode external to the device between the 1.8V supply and the 3.3V supply to force the 3.3V supply to be within one parasitic diode drop below the 1.8V supply (i.e., VDDIO > VDD - ~0.4V). The second method is to ramp up the 3.3V supply first and then ramp up the 1.8V supply. 7.12 Initialization After power-up or reset, a series of writes must be done to the DS3106 to tune it for optimal performance. This series of writes is called the initialization script. Each DS3106 die revision has a different initialization script. Download the latest initialization scripts from the DS3106 webpage at www.maxim-ic.com/DS3106. Important: System software must wait at least 100µs after reset (RST pin or RST bit) is deasserted before initializing the device. 19-4629; Rev 3; 5/09 36 of 87 ____________________________________________________________________________________________ DS3106 8. Register Descriptions The DS3106 has an overall address range from 000h to 1FFh. Table 8-1 in Section 8.4 shows the register map. In each register, bit 7 is the MSB and bit 0 is the LSB. Register addresses not listed and bits marked “—“ are reserved and must be written with 0. Writing other values to these registers may put the device in a factory test mode resulting in undefined operation. Bits labeled “0” or “1” must be written with that value for proper operation. Register fields with underlined names are read-only fields; writes to these fields have no effect. All other fields are readwrite. Register fields are described in detail in the register descriptions that follow Table 8-1. Note: Systems must be able to access the entire address range from 0 to 01FFh. Proper device initialization requires a sequence of writes to addresses in the range 0180-01FFh. 8.1 Status Bits The device has two types of status bits. Real-time status bits are read-only and indicate the state of a signal at the time it is read. Latched status bits are set when a signal changes state (low-to-high, high-to-low, or both, depending on the bit) and cleared when written with a logic 1 value. Writing a 0 has no effect. When set, some latched status bits can cause an interrupt request on the INTREQ pin if enabled to do so by corresponding interrupt enable bits. ISR#.LOCK# are special-case latched status bits because they cannot create an interrupt request on the INTREQ pin and a “write 0” is needed to clear them. 8.2 Configuration Fields Configuration fields are read-write. During reset, each configuration field reverts to the default value shown in the register definition. Configuration register bits marked “—” are reserved and must be written with 0. 8.3 Multiregister Fields Multiregister fields—such as FREQ[18:0] in registers FREQ1, FREQ2, and FREQ3—must be handled carefully to ensure that the bytes of the field remain consistent. A write access to a multiregister field is accomplished by writing all the registers of the field in any order, with no other accesses to the device in between. If the write sequence is interrupted by another access, none of the bytes are written and the MSR4:MRAA latched status bit is set to indicate the write was aborted. A read access from a multiregister field is accomplished by reading the registers of the field in any order, with no other accesses to the device in between. When one register of a multiregister field is read, the other register(s) in the field are frozen until after they are all read. If the read sequence is interrupted by another access, the registers of the multibyte field are unfrozen and the MSR4:MRAA bit is set to indicate the read was aborted. For best results, interrupt servicing should be disabled in the microprocessor before a multiregister access and then enabled again after the access is complete. The multiregister fields are: FIELD FREQ[18:0] MCLKFREQ[15:0] HARDLIM[9:0] DIVN[15:0] PHASE[15:0] 19-4629; Rev 3; 5/09 REGISTERS FREQ1, FREQ2, FREQ3 MCLK1, MCLK2 DLIMIT1, DLIMIT2 DIVN1, DIVN2 PHASE1, PHASE2 ADDRESSES 0Ch, 0Dh, 07h 3Ch, 3Dh 41h, 42h 46h, 47h 77h, 78h TYPE Read Only Read/Write Read/Write Read/Write Read Only 37 of 87 ____________________________________________________________________________________________ DS3106 8.4 Register Definitions Table 8-1. Register Map Note: Register names are hyperlinks to register definitions. Underlined fields are read-only. ADDR 00h 01h 02h 03h 05h 06h 07h 09h 0Ah 0Ch 0Dh 0Eh 11h 17h 22h 23h 32h 34h 38h 39h 3Ah 3Bh 3Ch 3Dh 40h 41h 42h 43h 44h 46h 47h 48h 4Dh 4Eh 4Fh 50h 51h 52h 53h 61h 62h 63h 64h 65h REGISTER BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 ID1 ID[7:0] ID2 ID[15:8] REV REV[7:0] TEST1 PALARM D180 — RA 0 8KPOL 0 0 MSR1 — — — — IC4 IC3 — — MSR2 STATE SRFAIL — — — — — — FREQ3 — — — — — FREQ[18:16] OPSTATE — — T0SOFT — — T0STATE[2:0] PTAB1 — — — — SELREF[3:0] FREQ1 FREQ[7:0] FREQ2 FREQ[15:8] VALSR1 — — — — IC4 IC3 — — ISR2 — — ACT4 — — — ACT3 — MSR4 — HORDY MRAA — — — — — ICR3 DIVN LOCK8K — — FREQ[3:0] ICR4 DIVN LOCK8K — — FREQ[3:0] MCR1 RST — FREN LOCKPIN — T0STATE[2:0] MCR3 — — XOEDGE FRUNHO — SONSDH — — MCR6 DIG2AF DIG2SS DIG1SS — — — — — MCR7 DIG2F[1:0] DIG1F[1:0] — — MCR8 — — — — — — OC6SF[1:0] MCR9 AUTOBW — — — LIMINT — — — MCLK1 MCLKFREQ[7:0] MCLK2 MCLKFREQ[15:8] HOCR3 AVG — — — — — — — DLIMIT1 HARDLIM[7:0] DLIMIT2 — — — — — — HARDLIM[9:8] IER1 — — — — IC4 IC3 — — IER2 STATE SRFAIL — — — — — IC9 DIVN1 DIVN[7:0] DIVN2 DIVN[15:8] MCR10 — SRFPIN — — — — — — DLIMIT3 FLLOL SOFTLIM[6:0] IER4 — HORDY — — — — — — OCR5 — — AOF6 — — AOF3 — — LB0U LB0U[7:0] LB0L LB0L[7:0] LB0S LB0S[7:0] LB0D — — — — — — LB0D[1:0] OCR2 — — — — OFREQ3[3:0] OCR3 OFREQ6[3:0] — — — — OCR4 MFSEN FSEN — — — — — — T4CR1 — — — — T4FREQ[3:0] T0CR1 — T4APT0 T0FT4[2:0] T0FREQ[2:0] 19-4629; Rev 3; 5/09 38 of 87 ____________________________________________________________________________________________ DS3106 ADDR REGISTER BIT 7 BIT 6 67h 69h 6Bh 6Dh 6Eh 6Fh 73h 74h 76h 77h 78h 7Ah 7Dh 7Eh 7Fh1FFh T0LBW T0ABW T0CR2 T0CR3 GPCR GPSR PHLIM1 PHLIM2 PHMON PHASE1 PHASE2 FSCR1 INTCR PROT — — — PD2EN GPIO4D — FLEN CLEN NW — — reserved — — — BIT 5 BIT 4 BIT 3 — RSV1 RSV2 — RSV1 RSV2 PD2G8K[2:0] — — — — — GPIO3D GPIO2D GPIO1D GPIO4O — — — GPIO4 NALOL 1 — — MCPDEN USEMCPD — — — — PHASE[7:0] PHASE[15:8] — — — 8KINV — — — LOS PROT[7:0] — — — — BIT 2 BIT 1 BIT 0 T0LBW[2:0] T0ABW[2:0] DAMP[2:0] PD2G[2:0] GPIO3O GPIO2O GPIO1O GPIO3 GPIO2 GPIO1 FINELIM[2:0] COARSELIM[3:0] — 8KPUL GPO 2KINV OD 2KPUL POL — — — Register Map Color Coding Device Identification and Protection Local Oscillator and Master Clock Configuration Input Clock Configuration Input Clock Monitoring Input Clock Selection DPLL Configuration DPLL State Output Clock Configuration Frame/Multiframe-Sync Configuration 19-4629; Rev 3; 5/09 39 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default 7 ID1 Device Identification Register, LSB 00h 6 5 4 3 2 1 0 0 0 0 0 3 2 1 0 1 1 0 0 3 2 1 0 0 0 0 0 ID[7:0] 0 0 1 0 Bits 7 to 0: Device ID (ID[7:0]). ID[15:0] = 0C22h = 3106 decimal. Register Name: Register Description: Register Address: Bit # Name Default 7 ID2 Device Identification Register, MSB 01h 6 5 4 ID[15:8] 0 0 0 0 Bits 7 to 0: Device ID (ID[15:8]). See the ID1 register description. Register Name: Register Description: Register Address: Bit # Name Default 7 REV Device Revision Register 02h 6 5 4 REV[7:0] 0 0 0 0 Bits 7 to 0: Device Revision (REV[7:0]). Contact the factory to interpret this value and determine the latest revision. 19-4629; Rev 3; 5/09 40 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default 7 PALARM 0 TEST1 Test Register 1 (Not Normally Used) 03h 6 D180 0 5 — 0 4 RA 1 3 0 0 2 8KPOL 1 1 0 0 0 0 0 Bit 7: Phase Alarm (PALARM). This real-time status bit indicates the state of the T0 DPLL phase-lock detector. See Section 7.7.5. (Note: This is not the same as T0STATE = locked.) 0 = T0 DPLL phase-lock parameters are met (FLEN, CLEN, NALOL, FLLOL) 1 = T0 DPLL loss-of-phase lock Bit 6: Disable 180 (D180). When locking to a new reference, the T0 DPLL first tries nearest edge locking (180) for the first two seconds. If unsuccessful, it tries full phase/frequency locking (360). Disabling the nearest edge locking can reduce lock time by up to two seconds but may cause an unnecessary phase shift (up to 360) when the new reference is close in frequency/phase to the old reference. See Section 7.7.4. 0 = Normal operation: try nearest edge locking then phase/frequency locking 1 = Phase/frequency locking only Bit 4: Resync Analog Dividers (RA). When this bit is set the analog output dividers are always synchronized to ensure that low-frequency outputs are in sync with the higher frequency clock from the DPLL. 0 = Synchronized for the first two seconds after power-up 1 = Always synchronized Bits 3, 1, and 0: Leave set to zero (test control). Bit 2: 8kHz Edge Polarity (8KPOL). Specifies the input clock edge to lock to on the selected reference when it is configured for LOCK8K mode. See Section 7.4.2. 0 = Falling edge 1 = Rising edge 19-4629; Rev 3; 5/09 41 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default 7 — 1 MSR1 Master Status Register 1 05h 6 — 0 5 — 1 4 — 1 3 IC4 1 2 IC3 1 1 — 1 0 — 1 Bits 3 and 2: Input Clock Status Change (IC[3:2]). Each of these latched status bits is set to 1 when the VALSR1 status bit changes state (set or cleared). Each bit is cleared when written with a 1 and not set again until the VALSR1 bit changes state again. When one of these latched status bits is set, it can cause an interrupt request on the INTREQ pin if the corresponding interrupt enable bit is set in the IER1 register. See Section 7.5 for input clock validation/invalidation criteria. Register Name: Register Description: Register Address: Bit # Name Default 7 STATE 0 MSR2 Master Status Register 2 06h 6 SRFAIL 0 5 — 0 4 — 0 3 — 0 2 — 0 1 — 0 0 — 1 Bit 7: T0 DPLL State Change (STATE). This latched status bit is set to 1 when the operating state of the T0 DPLL changes. STATE is cleared when written with a 1 and not set again until the operating state changes again. When STATE is set it can cause an interrupt request on the INTREQ pin if the STATE interrupt enable bit is set in the IER2 register. The current operating state can be read from the T0STATE field of the OPSTATE register. See Section 7.7.1. Bit 6: Selected Reference Failed (SRFAIL). This latched status bit is set to 1 when the selected reference to the T0 DPLL fails, (i.e., no clock edges in two UI). SRFAIL is cleared when written with a 1. When SRFAIL is set it can cause an interrupt request on the INTREQ pin if the SRFAIL interrupt enable bit is set in the IER2 register. SRFAIL is not set in free-run mode or holdover mode. See Section 7.5.3. Register Name: Register Description: Register Address: Bit # Name Default 7 — 0 FREQ3 Frequency Register 3 07h 6 — 0 5 — 0 4 — 0 3 — 0 2 0 1 FREQ[18:16] 0 0 0 Bits 2 to 0: Current DPLL Frequency (FREQ[18:16]). See the FREQ1 register description. 19-4629; Rev 3; 5/09 42 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default 7 — 1 OPSTATE Operating State Register 09h 6 — 0 5 T0SOFT 0 4 — 0 3 — 0 2 0 1 T0STATE[2:0] 0 0 1 Bit 5: T0 DPLL Frequency Soft Alarm (T0SOFT). This real-time status bit indicates whether the T0 DPLL is tracking its reference within the soft alarm limits specified in the SOFT[6:0] field of the DLIMIT3 register. See Section 7.7.5. 0 = No alarm; frequency is within the soft alarm limits 1 = Soft alarm; frequency is outside the soft alarm limits Bits 2 to 0: T0 DPLL Operating State (T0STATE[2:0]). This real-time status field indicates the current state of the T0 DPLL state machine. Values not listed below correspond to invalid (unused) states. See Section 7.7.1. 001 = Free-run 010 = Holdover 100 = Locked 101 = Prelocked 2 110 = Prelocked 111 = Loss-of-lock Register Name: Register Description: Register Address: Bit # Name Default 7 — 0 PTAB1 Priority Table Register 1 0Ah 6 — 0 5 — 0 4 — 0 3 2 1 SELREF[3:0] see below 0 Bits 3 to 0: Selected Reference (SELREF[3:0]). This real-time status field indicates the current selected reference for the T0 DPLL. The default value for this field is 0011b if the SRCSW pin is 1 during reset and 0100b if SRCSW is 0 during reset. 0000 = No valid input reference available 0001 to 0010 = {unused values} 0011 = Input IC3 0100 = Input IC4 0101 to 1111 = {unused values} 19-4629; Rev 3; 5/09 43 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default 7 FREQ1 Frequency Register 1 0Ch 6 5 4 3 2 1 0 0 0 0 0 FREQ[7:0] 0 0 0 0 Note: The FREQ1, FREQ2, and FREQ3 registers must be read consecutively. See Section 8.3. Bits 7 to 0: Current DPLL Frequency (FREQ[7:0]). The full 19-bit FREQ[18:0] field spans this register, FREQ2, and FREQ3. FREQ is a two’s-complement signed integer that expresses the current frequency as an offset with respect to the master clock frequency (see Section 7.3). Because the value in this register field is derived from the DPLL integral path, it can be considered an average frequency with a rate of change inversely proportional to the DPLL bandwidth. If LIMINT = 1 in the MCR9 register, the value of FREQ freezes when the DPLL reaches its minimum or maximum frequency. The frequency offset in ppm is equal to FREQ[18:0] 0.0003068. See Section 7.7.1.6. Application Note: Frequency measurements are relative, i.e., they measure the frequency of the selected reference with respect to the local oscillator. As such, when a frequency difference exists, it is difficult to distinguish whether the selected reference is off frequency or the local oscillator is off frequency. In systems with timing card redundancy, the use of two timing cards, master and slave, can address this difficulty. Both master and slave have separate local oscillators, and each measures the selected reference. These two measurements provide the necessary information to distinguish which reference is off frequency, if we make the simple assumption that at most one reference has a significant frequency deviation at any given time (i.e., a single point of failure). If both master and slave indicate a significant frequency offset, then the selected reference must be off frequency. If the master indicates a frequency offset but the slave does not, then the master’s local oscillator must be off frequency. Likewise, if the slave indicates a frequency offset but the master does not, the slave’s local oscillator must be off frequency. Register Name: Register Description: Register Address: Bit # Name Default FREQ2 Frequency Register 2 0Dh 7 6 5 0 0 0 4 3 FREQ[15:8] 0 0 2 1 0 0 0 0 Bits 7 to 0: Current DPLL Frequency (FREQ[15:8]). See the FREQ1 register description. 19-4629; Rev 3; 5/09 44 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default 7 — 0 VALSR1 Input Clock Valid Status Register 1 0Eh 6 — 0 5 — 0 4 — 0 3 IC4 0 2 IC3 0 1 — 0 0 — 0 Bits 3 and 2: Input Clock Valid Status (IC[3:2]). Each of these real-time status bits is set to 1 when the corresponding input clock is valid. An input is valid if it has no active alarms (ACT = 0 in the ISR2 register). See also the MSR1 register and Section 7.5. 6 0 = Invalid 1 = Valid Register Name: Register Description: Register Address: Bit # Name Default 7 — 0 ISR2 Input Status Register 2 11h 6 — 0 5 ACT4 1 4 — 0 3 — 0 2 — 0 1 ACT3 1 0 — 0 Bit 5: Activity Alarm for Input Clock 4 (ACT4). This real-time status bit is set to 1 when the leaky bucket accumulator for IC4 reaches the alarm threshold specified in the LBxU register (where x in LBxU is specified in the BUCKET field of ICR4). An activity alarm clears the IC4 status bit in the VALSR1 register, invalidating the IC4 clock. See Section 7.5.2. Bit 1: Activity Alarm for Input Clock 3 (ACT3). This bit has the same behavior as the ACT4 bit but for the IC3 input clock. Register Name: Register Description: Register Address: Bit # Name Default 7 — 0 MSR4 Master Status Register 4 17h 6 HORDY 0 5 MRAA 0 4 — 0 3 — 0 2 — 0 1 — 0 0 — 0 Bit 6: Holdover Frequency Ready (HORDY). This latched status bit is set to 1 when the T0 DPLL has a holdover value that has been averaged over the one-second holdover averaging period. HORDY is cleared when written with a 1. When HORDY is set it can cause an interrupt request on the INTREQ pin if the HORDY interrupt enable bit is set in the IER4 register. See Section 7.7.1.6. Bit 5: Multiregister Access Aborted (MRAA). This latched status bit is set to 1 when a multibyte access (read or write) is interrupted by another access to the device. MRAA is cleared when written with a 1. MRAA cannot cause an interrupt to occur. See Section 8.3. 19-4629; Rev 3; 5/09 45 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default 7 DIVN 0 ICR3, ICR4 Input Configuration Register 3, 4 22h, 23h 6 LOCK8K 0 5 — 0 4 — 0 3 2 1 0 FREQ[3:0] see below Note: These registers are identical in function. ICRx is the control register for input clock ICx. Bit 7: DIVN Mode (DIVN). When DIVN is set to 1 and LOCK8K = 0, the input clock is divided down by a programmable predivider. The resulting output clock is then passed to the DPLL. All input clocks for which DIVN = 1 are divided by the factor specified in DIVN1 and DIVN2. When DIVN = 1 and LOCK8K = 0 in an ICR register, the FREQ field of that register must be set to the input frequency divided by the divide factor. When DIVN = 1 and LOCK8K = 1 in an ICR register, the FREQ field of that register is decoded as the alternate frequencies. See Sections 7.4.2.2 and 7.4.2.4. 16 16 0 = Disabled 1 = Enabled Bit 6: LOCK8K Mode (LOCK8K). When LOCK8K is set to 1 and DIVN = 0, the input clock is divided down by a preset predivider. The resulting output clock, which is always 8kHz, is then passed to the DPLL. LOCK8K is ignored when DIVN = 0 and FREQ[3:0] = 1001 (2kHz) or 1010 (4kHz). When DIVN = 1 and LOCK8K = 1 in an ICR register, the FREQ field of that register is decoded as the alternate frequencies. See Sections 7.4.2.2 and 7.4.2.3 16 0 = Disabled 1 = Enabled Bits 3 to 0: Input Clock Frequency (FREQ[3:0]). When DIVN = 0 and LOCK8K = 0 (standard direct-lock mode), this field specifies the input clock’s nominal frequency for direct-lock operation. When DIVN = 0 and LOCK8K = 1 (LOCK8K mode), this field specifies the input clock’s nominal frequency for LOCK8K operation. When DIVN = 1 and LOCK8K = 0 (DIVN mode), this field specifies the frequency after the DIVN divider (i.e., input frequency divided by DIVN + 1). When DIVN = 1 and LOCK8K = 1 (alternate direct-lock frequencies), this field specifies the input clock’s nominal frequency for direct-lock operation. DIVN = 0 or LOCK8K = 0: (Standard direct-lock mode, LOCK8K mode, or DIVN mode) 0000 = 8kHz 0001 = 1544kHz or 2048kHz (as determined by SONSDH bit in the MCR3 register) 0010 = 6.48MHz 0011 = 19.44MHz 0100 = 25.92MHz 0101 = 38.88MHz 0110 = 51.84MHz 0111 = 77.76MHz 1000 = 155.52MHz (only valid for LVDS inputs) 1001 = 2kHz 1010 = 4kHz 1011 = 6312kHz 1100 = 5MHz 1101 = 31.25 MHz (not a multiple of 8 kHz and therefore not valid for LOCK8K mode) 1110–1111 = undefined DIVN = 1 and LOCK8K = 1: (Alternate direct-lock frequency decode) 0000 = 10MHz (internally divided down to 5MHz) 0001 = 25MHz (internally divided down to 5MHz) 0010 = 62.5MHz (internally down to 31.25MHz) 0011 = 125MHz (internally down to 31.25MHz) 0101–1111 = undefined FREQ[3:0] Default Values: See Table 7-2. 19-4629; Rev 3; 5/09 46 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default 7 RST 0 MCR1 Master Configuration Register 1 32h 6 — 0 5 FREN 1 4 LOCKPIN 0 3 — 0 2 0 1 T0STATE[2:0] 0 0 0 Bit 7: Device Reset (RST). When this bit is high the entire device is held in reset, and all register fields, except the RST bit itself, are reset to their default states. When RST is active, the register fields with pin-programmed defaults do not latch their values from the corresponding input pins. Instead these fields are reset to the default values that were latched from the pins when the RST pin was last active. See Section 7.10. 0 = Normal operation 1 = Reset Bit 5: Frequency Range Detect Enable (FREN). When this bit is high the frequency of each input clock is measured and used to quickly declare the input inactive. See Section 7.5.1. 0 = Frequency range detect disabled. 1 = Frequency range detect enabled. Bit 4: T0 DPLL LOCK Pin Enable (LOCKPIN). When this bit is high the LOCK pin indicates when the T0 DPLL state machine is in the LOCK state (OPSTATE.T0STATE = 100). 0 = LOCK pin is not driven. 1 = LOCK pin is driven high when the T0 DPLL is in the lock state. Bits 2 to 0: T0 DPLL State Control (T0STATE[2:0]). This field allows the T0 DPLL state machine to be forced to a specified state. The state machine remains in the forced state, and, therefore, cannot react to alarms and other events as long as T0STATE is not equal to 000. See Section 7.7.1. 000 = Automatic (normal state machine operation) 001 = Free-run 010 = Holdover 011 = {unused value} 100 = Locked 101 = Prelocked 2 110 = Prelocked 111 = Loss-of-lock 19-4629; Rev 3; 5/09 47 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default MCR3 Master Configuration Register 3 34h 7 — 1 6 — 1 5 XOEDGE 0 4 FRUNHO 0 3 — 0 2 SONSDH see below 1 — 1 0 — 0 Bit 5: Local Oscillator Edge (XOEDGE). This bit specifies the significant clock edge of the local oscillator clock signal on the REFCLK input pin. The faster edge should be selected for best jitter performance. See Section 7.3. 0 = Rising edge 1 = Falling edge Bit 4: Free-Run Holdover (FRUNHO). When this bit is set to 1 the T0 DPLL holdover frequency is set to 0ppm so the output frequency accuracy is set by the external oscillator accuracy. This affects both mini-holdover and the holdover state. 0 = Digital holdover 1 = Free-run holdover, 0ppm Bit 2: SONET or SDH Frequencies (SONSDH). This bit specifies the clock rate for input clocks with FREQ = 0001 in the ICR registers (20h to 28h). During reset the default value of this bit is latched from the SONSDH pin. See Section 7.4.2. 16 0 = 2048kHz 1 = 1544kHz Register Name: Register Description: Register Address: Bit # Name Default 7 DIG2AF 0 MCR6 Master Configuration Register 6 38h 6 DIG2SS see below 5 DIG1SS see below 4 — 1 3 — 1 2 — 1 1 — 1 0 — 1 Bit 7: Digital Alternate Frequency (DIG2AF). Selects alternative frequencies. 0 = Digital2 N x E1 or N x DS1 frequency specified by DIG2SS and MCR7:DIG2F. 1 = Digital2 6.312MHz, 10MHz, or N x 19.44MHz frequency specified by DIG2SS and MCR7:DIG2F. Bit 6: Digital2 SONET or SDH Frequencies (DIG2SS). This bit specifies whether the clock rates generated by the Digital2 clock synthesizer are multiples of 1.544MHz (SONET compatible) or multiples of 2.048MHz (SDH compatible) or alternate frequencies. The specific multiple is set in the DIG2F field of the MCR7 register. When RST = 0 the default value of this bit is latched from the SONSDH pin. DIG2AF = 0: 0 = Multiples of 2048kHz 1 = Multiples of 1544kHz DIG2AF = 1: 6.312MHz, 10MHz, or N x 19.44MHz Bit 5: Digital1 SONET or SDH Frequencies (DIG1SS). This bit specifies whether the clock rates generated by the Digital1 clock synthesizer are multiples of 1544kHz (SONET compatible) or multiples of 2048kHz (SDH compatible). The specific multiple is set in the DIG1F field of the MCR7 register. When RST = 0 the default value of this bit is latched from the SONSDH pin. 0 = Multiples of 2048kHz 1 = Multiples of 1544kHz 19-4629; Rev 3; 5/09 48 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default MCR7 Master Configuration Register 7 39h 7 6 5 DIG2F[1:0] 0 4 DIG1F[1:0] 0 0 0 3 — 1 2 — 0 1 — 0 0 — 0 Bits 7 and 6: Digital2 Frequency (DIG2F[1:0]). This field, MCR6:DIG2SS, and MCR6:DIG2AF configure the frequency of the Digital2 clock synthesizer. DIG2AF = 0 DIG2SS = 1 00 = 1544kHz 01 = 3088kHz 10 = 6176kHz 11 = 12,352kHz DIG2SS = 0 00 = 2048kHz 01 = 4096kHz 10 = 8192kHz 11 = 16,384kHz DIG2AF = 1 DIG2SS = 1 00 = 19.44MHz 01 = 38.88MHz 10 = undefined 11 = undefined DIG2SS = 0 00 = 6.312MHz 01 = undefined 10 = 10MHz 11 = undefined Bits 5 and 4: Digital1 Frequency (DIG1F[1:0]). This field and MCR6:DIG1SS configure the frequency of the Digital1 clock synthesizer. DIG1SS = 1 00 = 1544kHz 01 = 3088kHz 10 = 6176kHz 11 = 12,352kHz 19-4629; Rev 3; 5/09 DIG1SS = 0 00 = 2048kHz 01 = 4096kHz 10 = 8192kHz 11 = 16,384kHz 49 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default 7 — 0 MCR8 Master Configuration Register 8 3Ah 6 — 0 5 — 0 4 — 0 3 — 0 2 — 0 1 0 OC6SF[1:0] 1 0 For Rev A2 devices, in LVPECL mode the differential output voltage will be higher than the MAX VODPECL spec in Table 10-5 unless an adjustment register is written with the proper value. If differential voltages larger than VODPECL,MAX are unacceptable, the following procedures must be followed when writing the OC6SF fields in this register. If differential voltages larger than VODPECL,MAX are acceptable, only the OC6SF field must be written. Procedure to configure OC6 for LVPECL mode: 1) Set the OC6SF[1:0] field to 01b. 2) Write 01h to address 01FFh. 3) Write 55h to the adjustment register at address 01D8h. 4) Write 00h to address 01FFh. Procedure to configure OC6 for LVDS mode: 1) Set the OC6SF[1:0] field to 10b. 2) Write 01h to address 01FFh. 3) Write 00h to the adjustment register at address 01D8h. 4) Write 00h to address 01FFh. Bits 1 and 0: Output Clock 6 Signal Format (OC6SF[1:0]). See Section 7.8.1. 00 = Output disabled (powered down) 01 = 3V LVPECL level compatible 10 = 3V LVDS compatible (default) 11 = 3V LVDS compatible Register Name: Register Description: Register Address: Bit # Name Default 7 AUTOBW 1 MCR9 Master Configuration Register 9 3Bh 6 — 1 5 — 1 4 — 1 3 LIMINT 1 2 — 0 1 — 1 0 — 1 Bit 7: Automatic Bandwidth Selection (AUTOBW). See Section 7.7.2. 0 = Always selects locked bandwidth from the T0LBW register. 1 = Automatically selects either locked bandwidth (T0LBW register) or acquisition bandwidth (T0ABW register) as appropriate. Bit 3: Limit Integral Path (LIMINT). When this bit is set to 1, the T0 DPLL’s integral path is limited (i.e., frozen) when the DPLL reaches minimum or maximum frequency, as set by the HARDLIM field in DLIMIT1 and DLIMIT2. When the integral path is frozen, the current DPLL frequency in registers FREQ1, FREQ2, and FREQ3 is also frozen. Setting LIMINT = 1 minimizes overshoot when the DPLL is pulling in. See Section 7.7.2. 0 = Do not freeze integral path at min/max frequency. 1 = Freeze integral path at min/max frequency. 19-4629; Rev 3; 5/09 50 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default MCLK1 Master Clock Frequency Adjustment Register 1 3Ch 7 6 5 1 0 0 4 3 MCLKFREQ[7:0] 1 1 2 1 0 0 0 1 Note: The MCLK1 and MCLK2 registers must be read consecutively and written consecutively. See Section 8.3. Bits 7 to 0: Master Clock Frequency Adjustment (MCLKFREQ[7:0]). The full 16-bit MCLKFREQ[15:0] field spans this register and MCLK2. MCLKFREQ is an unsigned integer that adjusts the frequency of the internal 204.8MHz master clock with respect to the frequency of the local oscillator clock on the REFCLK pin by up to +514ppm and -771ppm. The master clock adjustment has the effect of speeding up the master clock with a positive adjustment and slowing it down with a negative adjustment. For example, if the oscillator connected to REFCLK has an offset of +1ppm, the adjustment should be -1ppm to correct the offset. The formulas below translate adjustments to register values and vice versa. The default register value of 39,321 corresponds to 0ppm. See Section 7.3. MCLKFREQ[15:0] = adjustment_in_ppm / 0.0196229 + 39,321 adjustment_in_ppm = (MCLKFREQ[15:0] – 39,321) 0.0196229 Register Name: Register Description: Register Address: Bit # Name Default MCLK2 Master Clock Frequency Adjustment Register 2 3Dh 7 6 5 1 0 0 4 3 MLCKFREQ[15:8] 1 1 2 1 0 0 0 1 Bits 7 to 0: Master Clock Frequency Adjustment (MCLKFREQ[15:8]). See the MCLK1 register description. Register Name: Register Description: Register Address: Bit # Name Default 7 AVG 1 HOCR3 Holdover Configuration Register 3 40h 6 — 0 5 — 0 4 — 0 3 — 1 2 — 0 1 — 0 0 — 0 Note: See Section 8.3 for important information about writing and reading this register. Bit 7: Averaging (AVG). When this bit is set to 1 the T0 DPLL uses the averaged frequency value during holdover mode. When FRUNHO = 1 in the MCR3 register, this bit is ignored. See Section 7.7.1.6. 0 = Not averaged frequency; holdover frequency is either free-run (FRUNHO = 1) or instantaneously frozen. 1 = Averaged frequency over the last one second while locked to the input. 19-4629; Rev 3; 5/09 51 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default DLIMIT1 DPLL Frequency Limit Register 1 41h 7 6 5 1 1 1 4 3 HARDLIM[7:0] 1 1 2 1 0 1 1 1 Note: The DLIMIT1 and DLIMIT2 registers must be read consecutively and written consecutively. See Section 8.3. Bits 7 to 0: DPLL Hard Frequency Limit (HARDLIM[7:0]). The full 10-bit HARDLIM[9:0] field spans this register and DLIMIT2. HARDLIM is an unsigned integer that specifies the hard frequency limit or pull-in/hold-in range of the T0 DPLL. When frequency limit detection is enabled by setting FLLOL = 1 in the DLIMIT3 register. If the DPLL frequency exceeds the hard limit the DPLL declares loss-of-lock. The hard frequency limit in ppm is HARDLIM[9:0] 0.0782. The default value is normally 79.794ppm (3FFh). See Section 7.7.5. Register Name: Register Description: Register Address: Bit # Name Default 7 — 0 DLIMIT2 DPLL Frequency Limit Register 1 42h 6 — 0 5 — 0 4 — 0 3 — 0 2 — 0 1 0 HARDLIM[9:8] 1 1 Bits 1 and 0: DPLL Hard Frequency Limit (HARDLIM[9:8]). See the DLIMIT1 register description. 19-4629; Rev 3; 5/09 52 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default 7 — 0 IER1 Interrupt Enable Register 1 43h 6 — 0 5 — 0 4 — 0 3 IC4 0 2 IC3 0 1 — 0 0 — 0 Bits 3 and 2: Interrupt Enable for Input Clock Status Change (IC[3:2]). Each of these bits is an interrupt enable control for the corresponding bit in the MSR1 register. 0 = Mask the interrupt 1 = Enable the interrupt Register Name: Register Description: Register Address: Bit # Name Default 7 STATE 0 IER2 Interrupt Enable Register 2 44h 6 SRFAIL 0 5 — 0 4 — 0 3 — 0 2 — 0 1 — 0 0 — 0 Bit 7: Interrupt Enable for T0 DPLL State Change (STATE). This bit is an interrupt enable for the STATE bit in the MSR2 register. 0 = Mask the interrupt 1 = Enable the interrupt Bit 6: Interrupt Enable for Selected Reference Failed (SRFAIL). This bit is an interrupt enable for the SRFAIL bit in the MSR2 register. 0 = Mask the interrupt 1 = Enable the interrupt 19-4629; Rev 3; 5/09 53 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default 7 DIVN1 DIVN Register 1 46h 6 5 4 3 2 1 0 1 1 1 1 DIVN[7:0] 1 1 1 1 Note: The DIVN1 and DIVN2 registers must be read consecutively and written consecutively. See Section 8.3. Bits 7 to 0: DIVN Factor (DIVN[7:0]). The full 16-bit DIVN[15:0] field spans this register and DIVN2. This field contains the integer value used to divide the frequency of input clocks that are configured for DIVN mode. The frequency is divided by DIVN[15:0] + 1. See Section 7.4.2.4. Register Name: Register Description: Register Address: Bit # Name Default 7 DIVN2 DIVN Register 2 47h 6 5 4 3 2 1 0 1 1 1 1 2 — 0 1 — 0 0 — 0 DIVN[15:8] 0 0 1 1 Bits 7 to 0: DIVN Factor (DIVN[15:8]). See the DIVN1 register description. Register Name: Register Description: Register Address: Bit # Name Default 7 — 1 MCR10 Master Configuration Register 10 48h 6 SRFPIN 0 5 — 0 4 — 1 3 — 0 Bit 6: SRFAIL Pin Enable (SRFPIN). When this bit is set to 1, the SRFAIL pin is enabled. When enabled the SRFAIL pin follows the state of the SRFAIL status bit in the MSR2 register. This gives the system a very fast indication of the failure of the current reference. See Section 7.5.3. 0 = SRFAIL pin disabled (not driven) 1 = SRFAIL pin enabled 19-4629; Rev 3; 5/09 54 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default DLIMIT3 DPLL Frequency Limit Register 3 4Dh 7 FLLOL 1 6 5 4 0 0 0 3 SOFTLIM[6:0] 1 2 1 0 1 1 0 Bit 7: Frequency Limit Loss-of-Lock (FLLOL). When this bit is set to 1, the T0 DPLL internally declares loss-oflock when the hard frequency limit in the DLIMIT1 and DLIMIT2 registers is reached. See Section 7.7.5. 0 = DPLL declares loss-of-lock normally. 1 = DPLL also declares loss-of-lock when the hard frequency limit is reached. Bits 6 to 0: DPLL Soft Frequency Limit (SOFTLIM[6:0]). This field is an unsigned integer that specifies the soft frequency limit for the T0 DPLL. The soft limit is only used for monitoring; exceeding this limit does not cause lossof-lock. The limit in ppm is SOFTLIM[6:0] 0.628. The default value is 8.79ppm. When the T0 DPLL frequency reaches the soft limit, the T0SOFT status bit is set in the OPSTATE register. See Section 7.7.5. Register Name: Register Description: Register Address: Bit # Name Default 7 — 0 IER4 Interrupt Enable Register 4 4Eh 6 HORDY 0 5 — 0 4 — 0 3 — 0 2 — 0 1 — 0 0 — 0 Bit 6: Interrupt Enable for Holdover Frequency Ready (HORDY). This bit is an interrupt enable for the HORDY bit in the MSR4 register. 0 = Mask the interrupt 1 = Enable the interrupt Register Name: Register Description: Register Address: Bit # Name Default 7 — 0 OCR5 Output Configuration Register 1 4Fh 6 — 0 5 AOF6 0 4 — 0 3 — 0 2 AOF3 0 1 — 0 0 — 0 Bit 5: Alternate Output Frequency Mode Select 6 (AOF6). This bit controls the decoding of the OCR3.OFREQ6 field for the OC6 pin. 0 = Standard decodes 1 = Alternate decodes Bit 2: Alternate Output Frequency Mode Select 3 (AOF3). This bit controls the decoding of the OCR2.OFREQ3 field for the OC3 pin. 0 = Standard decodes 1 = Alternate decodes 19-4629; Rev 3; 5/09 55 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default 7 LB0U Leaky Bucket 0 Upper Threshold Register 50h 6 5 4 3 2 1 0 0 1 1 0 LB0U[7:0] 0 0 0 0 Bits 7 to 0: Leaky Bucket 0 Upper Threshold (LB0U[7:0]). When the leaky bucket accumulator is equal to the value stored in this field, the activity monitor declares an activity alarm by setting the input clock’s ACT bit in the ISR2 register. Registers LB0U, LB0L, LB0S, and LB0D together specify leaky bucket configuration 0. See Section 7.5.2. 7 Register Name: Register Description: Register Address: Bit # Name Default 7 LB0L Leaky Bucket 0 Lower Threshold Register 51h 6 5 4 3 2 1 0 0 1 0 0 LB0L[7:0] 0 0 0 0 Bits 7 to 0: Leaky Bucket 0 Lower Threshold (LB0L[7:0]). When the leaky bucket accumulator is equal to the value stored in this field, the activity monitoring logic clears the activity alarm (if previously declared) by clearing the input clock’s ACT bit in the ISR2 register. Registers LB0U, LB0L, LB0S, and LB0D together specify leaky bucket configuration 0. See Section 7.5.2. 17 Register Name: Register Description: Register Address: Bit # Name Default 7 LB0S Leaky Bucket 0 Size Register 52h 6 5 4 3 2 1 0 1 0 0 0 LB0S[7:0] 0 0 0 0 Bits 7 to 0: Leaky Bucket 0 Size (LB0S[7:0]). This field specifies the maximum value of the leaky bucket. The accumulator cannot increment past this value. Registers LB0U, LB0L, LB0S, and LB0D together specify leaky bucket configuration 0. See Section 7.5.2. Register Name: Register Description: Register Address: Bit # Name Default 7 — 0 LB0D Leaky Bucket 0 Decay Rate Register 53h 6 — 0 5 — 0 4 — 0 3 — 0 2 — 0 1 0 LB0D[1:0] 0 1 Bits 1 and 0: Leaky Bucket 0 Decay Rate (LB0D[1:0]). This field specifies the decay or “leak” rate of the leaky bucket accumulator. For each period of 1, 2, 4, or 8 128ms intervals in which no irregularities are detected on the input clock, the accumulator decrements by 1. Registers LB0U, LB0L, LB0S, and LB0D together specify leaky bucket configuration 0. See Section 7.5.2. 00 = decrement every 128ms (8 units/second) 01 = decrement every 256ms (4 units/second) 10 = decrement every 512ms (2 units/second) 11 = decrement every 1024ms (1 unit/second) 19-4629; Rev 3; 5/09 56 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default 7 0 0 OCR2 Output Configuration Register 2 61h 6 0 0 5 0 0 4 0 0 3 2 1 OFREQ3[3:0] see below 0 Bits 3 to 0: Output Frequency of OC3 (OFREQ3[3:0]). This field specifies the frequency of output clock OC3. The frequencies of the T0 APLL and T4 APLL are configured in the T0CR1 and T4CR1 registers. The Digital1 and Digital2 frequencies are configured in the MCR7 register. See Section 7.8.2.3. The default frequency is set by the O3F[2:0] bits. See Table 7-17. The decode of this field is controlled by the value of the OCR5.AOF3 bit. AOF3 = 0: (standard decodes) 0000 = Output disabled (i.e., low) 0001 = 2kHz 0010 = 8kHz 0011 = Digital2 (see Table 7-7) 0100 = Digital1 (see Table 7-6) 0101 = T0 APLL frequency divided by 48 0110 = T0 APLL frequency divided by 16 0111 = T0 APLL frequency divided by 12 1000 = T0 APLL frequency divided by 8 1001 = T0 APLL frequency divided by 6 1010 = T0 APLL frequency divided by 4 1011 = T4 APLL frequency divided by 64 1100 = T4 APLL frequency divided by 48 1101 = T4 APLL frequency divided by 16 1110 = T4 APLL frequency divided by 8 1111 = T4 APLL frequency divided by 4 AOF3 = 1: (alternate decodes) 0000 = Output disabled (i.e., low) 0001 = T0 APLL frequency divided by 64 0010 = T4 APLL frequency divided by 20 0011 = T4 APLL frequency divided by 12 0100 = T4 APLL frequency divided by 10 0101 = T4 APLL frequency divided by 5 0110 = T4 APLL frequency divided by 2 0111 = undefined 1000 = T0 selected reference (after dividing) 1001–1111 = undefined 19-4629; Rev 3; 5/09 57 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default 7 OCR3 Output Configuration Register 3 62h 6 5 OFREQ6[3:0] see below 4 3 0 0 2 0 0 1 0 0 0 0 0 Bits 7 to 4: Output Frequency of OC6 (OFREQ6[3:0]). This field specifies the frequency of output clock output OC6. The frequencies of the T0 APLL and T4 APLL are configured in the T0CR1 and T4CR1 registers. The Digital1 and Digital2 frequencies are configured in the MCR7 register. See Section 7.8.2.3. The default frequency is set by the OC6[2:0] bits. See Table 7-16. The decode of this field is controlled by the value of the OCR5.AOF6 bit. AOF6 = 0: (standard decodes) 0000 = Output disabled (i.e., low) 0001 = 2kHz 0010 = 8kHz 0011 = T0 APLL frequency divided by 2 0100 = Digital1 (see Table 7-6) 0101 = T0 APLL frequency 0110 = T0 APLL frequency divided by 16 0111 = T0 APLL frequency divided by 12 1000 = T0 APLL frequency divided by 8 1001 = T0 APLL frequency divided by 6 1010 = T0 APLL frequency divided by 4 1011 = T4 APLL frequency divided by 64 1100 = T4 APLL frequency divided by 48 1101 = T4 APLL frequency divided by 16 1110 = T4 APLL frequency divided by 8 1111 = T4 APLL frequency divided by 4 AOF6 = 1: (alternate decodes) 0000 = Output disabled (i.e., low) 0001 = T4 APLL frequency divided by 5 0010 = T4 APLL frequency divided by 2 0011 = T4 APLL frequency 0100 = T0 APLL2 frequency divided by 5 0101 = T0 APLL2 frequency divided by 2 0110 = T0 APLL2 frequency 0111 = T4 selected reference (after dividing) 1000 = T0 selected reference (after dividing) 1001–1111 = undefined 19-4629; Rev 3; 5/09 58 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default 7 MFSEN 1 OCR4 Output Configuration Register 4 63h 6 FSEN 1 5 0 0 4 0 0 3 0 0 2 0 0 1 0 0 0 0 0 Bit 7: MFSYNC Enable (MFSEN). This configuration bit enables the 2kHz output on the MFSYNC pin. See Section 7.8.2.5. 0 = Disabled, driven low 1 = Enabled, output is 2kHz Bit 6: FSYNC Enable (FSEN). This configuration bit enables the 8kHz output on the FSYNC pin. See Section 7.8.2.5. 0 = Disabled, driven low 1 = Enabled, output is 8kHz Register Name: Register Description: Register Address: Bit # Name Default 7 — 0 T4CR1 T4 DPLL Configuration Register 1 64h 6 — 0 5 — 0 4 — 0 3 2 1 T4FREQ[3:0] see below 0 Bits 3 to 0: T4 APLL Frequency (T4FREQ[3:0]). When T0CR1:T4APT0 = 0, this field configures the T4 APLL DFS frequency. The T4 APLL DFS frequency affects the frequency of the T4 APLL which, in turn, affects the available output frequencies on the output clock pins (see the OCR registers). See Section 7.8.2. The default value of this field is controlled by the O6F[2:0] and O3F[2:0] pins as described in Table 7-15. T4FREQ[3:0] 0000 0001 0010 0011 0100 0101 0110 0111 1000 1001 1010 1011 1100 1101–1111 19-4629; Rev 3; 5/09 T4 APLL DFS FREQUENCY APLL output disabled 77.76MHz 24.576MHz (12 x E1) 32.768MHz (16 x E1) 37.056MHz (24 x DS1) 24.704MHz (16 x DS1) 68.736MHz (2 x E3) 44.736MHz (DS3) 25.248MHz (4 x 6312kHz) 62.500MHz (GbE 16) 30.720MHz (3 x 10.24) 40.000MHz (4 x 10MHz) 26.000MHz (2 x 13MHz) {unused values} T4 APLL FREQUENCY (4 x T4 APLL DFS) Disabled, output is low 311.04MHz (4 x 77.76MHz) 98.304MHz (48 x E1) 131.072MHz (64 x E1) 148.224MHz (96 x DS1) 98.816MHz (64 x DS1) 274.944MHz (8 x E3) 178.944MHz (4 x DS3) 100.992MHz (16 x 6312kHz) 250.000MHz (GbE 4) 122.880MHz (12 x 10.24) 160.000MHz (16 x 10MHz) 104.000MHz (8 x 13MHz) {unused values} 59 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default 7 — 0 T0CR1 T0 DPLL Configuration Register 1 65h 6 T4APT0 0 5 0 4 T0FT4[2:0] 0 3 0 2 1 T0FREQ[2:0] see below 0 Bit 6: T4 APLL Source from T0 (T4APT0). When this bit is set to 0, T4CR1:T4FREQ configures the T4 APLL DFS frequency. The T4 APLL DFS frequency affects the frequency of the T4 APLL, which, in turn, affects the available output frequencies on the output clock pins (see the OCR registers). When this bit is set to 1, the frequency of the T4 APLL DFS is configured by the T0CR1:T0FT4[2:0] field below. See Section 7.8.2. 0 = T4 APLL frequency is determined by T4FREQ. 1 = T4 APLL frequency is determined by T0FT4. Bits 5 to 3: T0 Frequency to T4 APLL (T0FT4[2:0]). When the T4APT0 bit is set to 1, this field specifies the frequency of the T4 APLL DFS. This frequency can be different than the frequency specified by T0CR1:T0FREQ. See Section 7.8.2. T0FT4 000 = 001 = 010 = 011 = 100 = 101 = 110 = 111 = T4 APLL DFS FREQUENCY 24.576MHz (12 x E1) 62.500MHz (GbE 16) 32.768MHz (16 x E1) {unused value} 37.056MHz (24 x DS1) {unused value} 24.704MHz (16 x DS1) 25.248MHz (4 x 6312kHz) T4 APLL FREQUENCY (4 x T4 APLL DFS) 98.304MHz (48 x E1) 250.000MHz (GbE 4) 131.072MHz (64 x E1) {unused value} 148.224MHz (96 x DS1) {unused value} 98.816MHz (64 x DS1) 100.992MHz (16 x 6312kHz) Bits 2 to 0: T0 DPLL Output Frequency (T0FREQ[2:0]). This field configures the T0 APLL DFS frequency. The T0 APLL DFS frequency affects the frequency of the T0 APLL, which, in turn, affects the available output frequencies on the output clock pins (see the OCR registers). See Section 7.8.2. The default frequency is controlled by the O6F[2:0] and O3F[2:0] pins as described in Table 7-14. T0FREQ 000 = 001 = 010 = 011 = 100 = 101 = 110 = 111 = 19-4629; Rev 3; 5/09 T0 APLL DFS FREQUENCY 77.76MHz 77.76MHz 24.576MHz (12 x E1) 32.768MHz (16 x E1) 37.056MHz (24 x DS1) 24.704MHz (16 x DS1) 25.248MHz (4 x 6312kHz) 62.500MHz (GbE 16) T0 APLL FREQUENCY (4 x T0 APLL DFS) 311.04MHz (4 x 77.76MHz) 311.04MHz (4 x 77.76MHz) 98.304MHz (48 x E1) 131.072MHz (64 x E1) 148.224MHz (96 x DS1) 98.816MHz (64 x DS1) 100.992MHz (16 x 6312kHz) 250.000MHz (GbE 4) 60 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default 7 0 0 T0LBW T0 DPLL Locked Bandwidth Register 67h 6 0 0 5 0 0 4 RSV1 0 3 RSV2 0 2 0 1 T0LBW[2:0] 0 0 0 Bits 4 and 3: Reserved Bit 1 and 2 (RSV[1:2]). These bits are reserved for future use, and can be written to and read back. Bits 2 to 0: T0 DPLL Locked Bandwidth (T0LBW[2:0]). This field configures the bandwidth of the T0 DPLL when locked to an input clock. When AUTOBW = 0 in the MCR9 register, the T0LBW bandwidth is used for acquisition and for locked operation. When AUTOBW = 1, T0ABW bandwidth is used for acquisition while T0LBW bandwidth is used for locked operation. See Section 7.7.2. 111 = 18Hz 000 = 35Hz (default) 001 = 70Hz 010 = {unused value, undefined} 011 = 18Hz 100 = 120Hz 101 = 250Hz 110 = 400Hz Register Name: Register Description: Register Address: Bit # Name Default 7 0 0 T0ABW T0 DPLL Acquisition Bandwidth Register 69h 6 0 0 5 0 0 4 RSV1 0 3 RSV2 0 2 0 1 T0ABW[2:0] 0 0 1 Bits 4 and 3: Reserved Bit 1 and 2 (RSV[1:2]). These bits are reserved for future use, and can be written to and read back. Bits 2 to 0: T0 DPLL Acquisition Bandwidth (T0ABW[2:0]). This field configures the bandwidth of the T0 DPLL when acquiring lock. When AUTOBW = 0 in the MCR9 register, the T0LBW bandwidth is used for acquisition and for locked operation. When AUTOBW = 1, T0ABW bandwidth is used for acquisition while T0LBW bandwidth is used for locked operation. See Section 7.7.2. 111 = 18Hz 000 = 35Hz 001 = 70Hz (default) 010 = {unused value, undefined} 011 = 18Hz 100 = 120Hz 101 = 250Hz 110 = 400Hz 19-4629; Rev 3; 5/09 61 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default 7 — 0 T0CR2 T0 Configuration Register 2 6Bh 6 5 PD2G8K[2:0] 0 0 4 1 3 — 0 2 1 1 DAMP[2:0] 0 0 0 Bits 6 to 4: Phase Detector 2 Gain, 8kHz (PD2G8K[2:0]). This field specifies the gain of the T0 phase detector 2 with an input clock of 8kHz or less. This value is only used if automatic gain selection is enabled by setting PD2EN = 1 in the T0CR3 register. See Section 7.7.4. Bits 2 to 0: Damping Factor (DAMP[2:0]). This field configures the damping factor of the T0 DPLL. Damping factor is a function of both DAMP[2:0] and the T0 DPLL bandwidth (T0ABW and T0LBW). The default value corresponds to a damping factor of 5. See Section 7.7.3. 001 = 010 = 011 = 100 = 101 = 000, 110, and 111 = 18Hz 1.2 2.5 5 5 5 35Hz ≥ 70Hz 1.2 1.2 2.5 2.5 5 5 10 10 10 20 {unused values} The gain peak for each damping factor is shown below: DAMPING FACTOR 1.2 2.5 5 10 20 GAIN PEAK (dB) 0.4 0.2 0.1 0.06 0.03 Register Name: Register Description: Register Address: Bit # Name Default 7 PD2EN 1 T0CR3 T0 Configuration Register 3 6Dh 6 — 1 5 — 0 4 — 0 3 — 0 2 0 1 PD2G[2:0] 1 0 0 Bit 7: Phase Detector 2 Gain Enable (PD2EN). When this bit is set to 1, the T0 phase detector 2 is enabled and the gain is determined by the input locking frequency. If the frequency is greater than 8kHz, the gain is set by the PD2G field. If the frequency is less than or equal to 8kHz, the gain is set by the PD2G8K field in the T0CR2 register. See Section 7.7.4. 0 = Disable 1 = Enable Bits 2 to 0: Phase Detector 2 Gain (PD2G[2:0]). This field specifies the gain of the T0 phase detector 2 when the input frequency is greater than 8kHz. This value is only used if automatic gain selection is enabled by setting PD2EN = 1. See Section 7.7.4. 19-4629; Rev 3; 5/09 62 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default 7 GPIO4D 0 GPCR GPIO Configuration Register 6Eh 6 GPIO3D 0 5 GPIO2D 0 4 GPIO1D 0 3 GPIO4O 0 2 GPIO3O 0 1 GPIO2O 0 0 GPIO1O 0 Bit 7: GPIO4 Direction (GPIO4D). This bit configures the data direction for the GPIO4 pin. When GPIO4 is an input, its current state can be read from GPSR:GPIO4. When GPIO4 is an output, its value is controlled by the GPIO4O configuration bit. 0 = Input 1 = Output Bit 6: GPIO3 Direction (GPIO3D). This bit configures the data direction for the GPIO3 pin. When GPIO3 is an input, its current state can be read from GPSR:GPIO3. When GPIO3 is an output, its value is controlled by the GPIO3O configuration bit. 0 = Input 1 = Output Bit 5: GPIO2 Direction (GPIO2D). This bit configures the data direction for the GPIO2 pin. When GPIO2 is an input, its current state can be read from GPSR:GPIO2. When GPIO2 is an output, its value is controlled by the GPIO2O configuration bit. 0 = Input 1 = Output Bit 4: GPIO1 Direction (GPIO1D). This bit configures the data direction for the GPIO1 pin. When GPIO1 is an input, its current state can be read from GPSR:GPIO1. When GPI13 is an output, its value is controlled by the GPIO1O configuration bit. 0 = Input 1 = Output Bit 3: GPIO4 Output Value (GPIO4O). When GPIO4 is configured as an output (GPIO4D = 1), this bit specifies the output value. 0 = Low 1 = High Bit 2: GPIO3 Output Value (GPIO3O). When GPIO3 is configured as an output (GPIO3D = 1), this bit specifies the output value. 0 = Low 1 = High Bit 1: GPIO2 Output Value (GPIO2O). When GPIO2 is configured as an output (GPIO2D = 1), this bit specifies the output value. 0 = Low 1 = High Bit 0: GPIO1 Output Value (GPIO1O). When GPIO1 is configured as an output (GPIO1D = 1), this bit specifies the output value. 0 = Low 1 = High 19-4629; Rev 3; 5/09 63 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default 7 — 0 GPSR GPIO Status Register 6Fh 6 — 0 5 — 0 4 — 0 3 GPIO4 0 2 GPIO3 1 1 GPIO2 0 0 GPIO1 0 Bit 3: GPIO4 State (GPIO4). This bit indicates the current state of the GPIO4 pin. 0 = Low 1 = High Bit 2: GPIO3 State (GPIO3). This bit indicates the current state of the GPIO3 pin. 0 = Low 1 = High Bit 2: GPIO2 State (GPIO2). This bit indicates the current state of the GPIO2 pin. 0 = Low 1 = High Bit 1: GPIO1 State (GPIO1). This bit indicates the current state of the GPIO1 pin. 0 = Low 1 = High 19-4629; Rev 3; 5/09 64 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default 7 FLEN 1 PHLIM1 Phase Limit Register 1 73h 6 NALOL 0 5 1 1 4 — 0 3 — 0 2 0 1 FINELIM[2:0] 1 0 0 Bit 7: Fine Phase Limit Enable (FLEN). This configuration bit enables the fine phase limit specified in the FINELIM[2:0] field. The fine limit must be disabled for multi-UI jitter tolerance (see PHLIM2 fields). See Section 7.7.5. 0 = Disabled 1 = Enabled Bit 6: No Activity Loss-of-Lock (NALOL). The T0 and the T4 DPLLs can detect that an input clock has no activity very quickly (within two clock cycles). When NALOL = 0, loss-of-lock is not declared when clock cycles are missing, and nearest edge locking (180) is used when the clock recovers. This gives tolerance to missing cycles. When NALOL = 1, loss-of-lock is indicated as soon as no activity is detected, and the device switches to phase/frequency locking (360). See Sections 7.5.3 and 7.7.5. 0 = No activity does not trigger loss-of-lock. 1 = No activity does trigger loss-of-lock. Bit 5: Leave set to 1 (test control). Bits 2 to 0: Fine Phase Limit (FINELIM[2:0]). This field specifies the fine phase limit window, outside of which loss-of-lock is declared. The FLEN bit enables this feature. The phase of the input clock has to be inside the fine limit window for two seconds before phase lock is declared. Loss-of-lock is declared immediately if the phase of the input clock is outside the phase limit window. The default value of 010 is appropriate for most situations. See Section 7.7.5. 000 = Always indicates loss-of-phase lock—do not use 001 = Small phase limit window, 45 to 90 010 = Normal phase limit window, 90 to 180 (default) 100, 101, 110, 111 = Proportionately larger phase limit window 19-4629; Rev 3; 5/09 65 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default 7 CLEN 1 PHLIM2 Phase Limit Register 2 74h 6 MCPDEN 1 5 USEMCPD 1 4 — 0 3 0 2 1 COARSELIM[3:0] 1 0 0 1 Bit 7: Coarse Phase Limit Enable (CLEN). This configuration bit enables the coarse phase limit specified in the COARSELIM[3:0] field. See Section 7.7.5. 0 = Disabled 1 = Enabled Bit 6: Multicycle Phase Detector Enable (MCPDEN). This configuration bit enables the multicycle phase detector and allows the DPLL to tolerate large-amplitude jitter and wander. The range of this phase detector is the same as the coarse phase limit specified in the COARSELIM[3:0] field. See Section 7.7.4. 0 = Disabled 1 = Enabled Bit 5: Use Multicycle Phase Detector in the DPLL Algorithm (USEMCPD). This configuration bit enables the DPLL algorithm to use the multicycle phase detector so that a large phase measurement drives faster DPLL pull-in. When USEMCPD = 0, phase measurement is limited to 360, giving slower pull-in at higher frequencies but with less overshoot. When USEMCPD = 1, phase measurement is set as specified in the COARSELIM[3:0] field, giving faster pull-in. MCPDEN should be set to 1 when USEMCPD = 1. See Section 7.7.4. 0 = Disabled 1 = Enabled Bits 3 to 0: Coarse Phase Limit (COARSELIM[3:0]). This field specifies the coarse phase limit and the tracking range of the multicycle phase detector. The CLEN bit enables this feature. If jitter tolerance greater than 0.5UI is required and the input clock is a high-frequency signal, the DPLL can be configured to track phase errors over many UI using the multicycle phase detector. See Section 7.7.4 and 7.7.5. 0000 = 1UI 0001 = 3UI 0010 = 7UI 0011 = 15UI 0100 = 31UI 0101 = 63UI 0110 = 127UI 0111 = 255UI 1000 = 511UI 1001 = 1023UI 1010 = 2047UI 1011 = 4095UI 1100–1111 = 8191UI 19-4629; Rev 3; 5/09 66 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default 7 NW 0 PHMON Phase Monitor Register 76h 6 — 0 5 — 0 4 — 0 3 — 0 2 — 1 1 — 1 0 — 0 Bit 7: Low-Frequency Input Clock Noise Window (NW). For 2kHz, 4kHz, or 8kHz input clocks, this configuration bit enables a 5% tolerance noise window centered around the expected clock edge location. Noise-induced edges outside this window are ignored, reducing the possibility of phase hits on the output clocks. This only applies to the T0 DPLL and should be enabled only when the T0 DPLL is locked to an input and the 180 phase detector is being used. 0 = All edges are recognized by the T0 DPLL. 1 = Only edges within the 5% tolerance window are recognized by the T0 DPLL. Register Name: Register Description: Register Address: Bit # Name Default PHASE1 Phase Register 1 77h 7 6 5 0 0 0 4 3 PHASE[7:0] 0 0 2 1 0 0 0 0 Note: The PHASE1 and PHASE2 registers must be read consecutively. See Section 8.3. Bits 7 to 0: Current DPLL Phase (PHASE[7:0]). The full 16-bit PHASE[15:0] field spans this register and the PHASE2 register. PHASE is a two’s-complement signed integer that indicates the current value of the phase detector. The value is the output of the phase averager. The averaged phase difference in degrees is equal to PHASE 0.707. See Section 7.7.6. Register Name: Register Description: Register Address: Bit # Name Default PHASE2 Phase Register 2 78h 7 6 5 0 0 0 4 3 PHASE[15:8] 0 0 2 1 0 0 0 0 Bits 7 to 0: Current DPLL Phase (PHASE[15:8]). See the PHASE1 register description. 19-4629; Rev 3; 5/09 67 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default 7 — 0 FSCR1 Frame-Sync Configuration Register 1 7Ah 6 — 0 5 — 0 4 — 0 3 8KINV 0 2 8KPUL 0 1 2KINV 0 0 2KPUL 0 Bit 3: 8kHz Invert (8KINV). When this bit is set to 1, the 8kHz signal on clock output FSYNC is inverted. See Section 7.8.2.5. 0 = FSYNC not inverted 1 = FSYNC inverted Bit 2: 8kHz Pulse (8KPUL). When this bit is set to 1, the 8kHz signal on clock output FSYNC is pulsed rather than 50% duty cycle. In this mode output clock OC3 must be enabled, and the pulse width of FSYNC is equal to the clock period of OC3. See Section 7.8.2.5. 0 = FSYNC not pulsed; 50% duty cycle 1 = FSYNC pulsed, with pulse width equal to OC3 period Bit 1: 2kHz Invert (2KINV). When this bit is set to 1, the 2kHz signal on clock output MFSYNC is inverted. See Section 7.8.2.5. 0 = MFSYNC not inverted 1 = MFSYNC inverted Bit 0: 2kHz Pulse (2KPUL). When this bit is set to 1, the 2kHz signal on clock output MFSYNC is pulsed rather than 50% duty cycle. In this mode output clock OC3 must be enabled, and the pulse width of MFSYNC is equal to the clock period of OC3. See Section 7.8.2.5. 0 = MFSYNC not pulsed; 50% duty cycle 1 = MFSYNC pulsed, with pulse width equal to OC3 period 19-4629; Rev 3; 5/09 68 of 87 ____________________________________________________________________________________________ DS3106 Register Name: Register Description: Register Address: Bit # Name Default 7 — 0 INTCR Interrupt Configuration Register 7Dh 6 — 0 5 — 0 4 — 0 3 LOS 1 2 GPO 0 1 OD 1 0 POL 0 Bit 3: INTREQ Pin Mode (LOS). When GPO = 0, this bit selects the function of the INTREQ pin. 0 = The INTREQ/LOS pin indicates interrupt requests. 1 = The INTREQ/LOS pin indicates the real-time state of the selected reference activity monitor (see Section 7.5.3). Bit 2: INTREQ Pin General-Purpose Output Enable (GPO). When set to 1, this bit configures the interrupt request pin to be a general-purpose output whose value is set by the POL bit. 0 = INTREQ is function determined by the LOS bit. 1 = INTREQ is a general-purpose output. Bit 1: INTREQ Pin Open-Drain Enable (OD) When GPO = 0: 0 = INTREQ is driven in both inactive and active states. 1 = INTREQ is driven high or low in the active state but is high impedance in the inactive state. When GPO = 1: 0 = INTREQ is driven as specified by POL. 1 = INTREQ is high impedance and POL has no effect. Bit 0: INTREQ Pin Polarity (POL) When GPO = 0: 0 = INTREQ goes low to signal an interrupt request or LOS = 1 (active low). 1 = INTREQ goes high to signal interrupt request or LOS = 1 (active high). When GPO = 1: 0 = INTREQ driven low. 1 = INTREQ driven high. Register Name: Register Description: Register Address: Bit # Name Default 7 PROT Protection Register 7Eh 6 5 4 3 2 1 0 0 1 0 1 PROT[7:0] 1 0 0 0 Bits 7 to 0: Protection Control (PROT[7:0]). This field can be used to protect the rest of the register set from inadvertent writes. In protected mode writes to all other registers are ignored. In single unprotected mode, one register (other than PROT) can be written, but after that write the device reverts to protected mode (and the value of PROT is internally changed to 00h). In fully unprotected mode all registers can be written without limitation. See Section 7.2. 1000 0101 = Fully unprotected mode 1000 0110 = Single unprotected mode All other values = Protected mode 19-4629; Rev 3; 5/09 69 of 87 ____________________________________________________________________________________________ DS3106 9. JTAG Test Access Port and Boundary Scan 9.1 JTAG Description The DS3106 supports the standard instruction codes SAMPLE/PRELOAD, BYPASS, and EXTEST. Optional public instructions included are HIGHZ, CLAMP, and IDCODE. Figure 9-1 shows a block diagram. The DS3106 contains the following items, which meet the requirements set by the IEEE 1149.1 Standard Test Access Port and Boundary Scan Architecture: Test Access Port (TAP) TAP Controller Instruction Register Bypass Register Boundary Scan Register Device Identification Register The TAP has the necessary interface pins, namely JTCLK, JTRST, JTDI, JTDO, and JTMS. Details on these pins can be found in Table 6-5. Details about the boundary scan architecture and the TAP can be found in IEEE 1149.11990, IEEE 1149.1a-1993, and IEEE 1149.1b-1994. Figure 9-1. JTAG Block Diagram BOUNDARY SCAN REGISTER MUX DEVICE IDENTIFICATION REGISTER BYPASS REGISTER INSTRUCTION REGISTER SELECT TEST ACCESS PORT CONTROLLER 10k JTDI 19-4629; Rev 3; 5/09 10k 10k JTMS THREE-STATE JTCLK JTRST 70 of 87 ____________________________________________________________________________________________ DS3106 9.2 JTAG TAP Controller State Machine Description This section discusses the operation of the TAP controller state machine. The TAP controller is a finite state machine that responds to the logic level at JTMS on the rising edge of JTCLK. Each of the states denoted in Figure 9-2 is described in the following paragraphs. Test-Logic-Reset. Upon device power-up, the TAP controller starts in the Test-Logic-Reset state. The instruction register contains the IDCODE instruction. All system logic on the device operates normally. Run-Test-Idle. Run-Test-Idle is used between scan operations or during specific tests. The instruction register and all test registers remain idle. Select-DR-Scan. All test registers retain their previous state. With JTMS low, a rising edge of JTCLK moves the controller into the Capture-DR state and initiates a scan sequence. JTMS high moves the controller to the SelectIR-SCAN state. Capture-DR. Data can be parallel-loaded into the test register selected by the current instruction. If the instruction does not call for a parallel load or the selected test register does not allow parallel loads, the register remains at its current value. On the rising edge of JTCLK, the controller goes to the Shift-DR state if JTMS is low or to the Exit1DR state if JTMS is high. Shift-DR. The test register selected by the current instruction is connected between JTDI and JTDO and data is shifted one stage toward the serial output on each rising edge of JTCLK. If a test register selected by the current instruction is not placed in the serial path, it maintains its previous state. Exit1-DR. While in this state, a rising edge on JTCLK with JTMS high puts the controller in the Update-DR state, which terminates the scanning process. A rising edge on JTCLK with JTMS low puts the controller in the Pause-DR state. Pause-DR. Shifting of the test registers is halted while in this state. All test registers selected by the current instruction retain their previous state. The controller remains in this state while JTMS is low. A rising edge on JTCLK with JTMS high puts the controller in the Exit2-DR state. Exit2-DR. While in this state, a rising edge on JTCLK with JTMS high puts the controller in the Update-DR state and terminates the scanning process. A rising edge on JTCLK with JTMS low puts the controller in the Shift-DR state. Update-DR. A falling edge on JTCLK while in the Update-DR state latches the data from the shift register path of the test registers into the data output latches. This prevents changes at the parallel output because of changes in the shift register. A rising edge on JTCLK with JTMS low puts the controller in the Run-Test-Idle state. With JTMS high, the controller enters the Select-DR-Scan state. Select-IR-Scan. All test registers retain their previous state. The instruction register remains unchanged during this state. With JTMS low, a rising edge on JTCLK moves the controller into the Capture-IR state and initiates a scan sequence for the instruction register. JTMS high during a rising edge on JTCLK puts the controller back into the Test-Logic-Reset state. Capture-IR. The Capture-IR state is used to load the shift register in the instruction register with a fixed value. This value is loaded on the rising edge of JTCLK. If JTMS is high on the rising edge of JTCLK, the controller enters the Exit1-IR state. If JTMS is low on the rising edge of JTCLK, the controller enters the Shift-IR state. Shift-IR. In this state, the instruction register’s shift register is connected between JTDI and JTDO and shifts data one stage for every rising edge of JTCLK toward the serial output. The parallel register and the test registers remain at their previous states. A rising edge on JTCLK with JTMS high moves the controller to the Exit1-IR state. A rising edge on JTCLK with JTMS low keeps the controller in the Shift-IR state, while moving data one stage through the instruction shift register. 19-4629; Rev 3; 5/09 71 of 87 ____________________________________________________________________________________________ DS3106 Exit1-IR. A rising edge on JTCLK with JTMS low puts the controller in the Pause-IR state. If JTMS is high on the rising edge of JTCLK, the controller enters the Update-IR state and terminates the scanning process. Pause-IR. Shifting of the instruction register is halted temporarily. With JTMS high, a rising edge on JTCLK puts the controller in the Exit2-IR state. The controller remains in the Pause-IR state if JTMS is low during a rising edge on JTCLK. Exit2-IR. A rising edge on JTCLK with JTMS high puts the controller in the Update-IR state. The controller loops back to the Shift-IR state if JTMS is low during a rising edge of JTCLK in this state. Update-IR. The instruction shifted into the instruction shift register is latched into the parallel output on the falling edge of JTCLK as the controller enters this state. Once latched, this instruction becomes the current instruction. A rising edge on JTCLK with JTMS low puts the controller in the Run-Test-Idle state. With JTMS high, the controller enters the Select-DR-Scan state. Figure 9-2. JTAG TAP Controller State Machine Test-Logic-Reset 1 0 Run-Test/Idle 1 Select DR-Scan 1 0 1 Select IR-Scan 0 0 1 1 Capture-IR Capture-DR 0 0 Shift-DR Shift-IR 0 0 1 1 1 Exit1- DR 0 0 Pause-DR Pause-IR 0 1 0 0 Exit2-IR 1 1 Update-DR 19-4629; Rev 3; 5/09 0 1 Exit2-DR 1 1 Exit1-IR 0 Update-IR 1 0 72 of 87 ____________________________________________________________________________________________ DS3106 9.3 JTAG Instruction Register and Instructions The instruction register contains a shift register as well as a latched parallel output and is 3 bits in length. When the TAP controller enters the Shift-IR state, the instruction shift register is connected between JTDI and JTDO. While in the Shift-IR state, a rising edge on JTCLK with JTMS low shifts data one stage toward the serial output at JTDO. A rising edge on JTCLK in the Exit1-IR state or the Exit2-IR state with JTMS high moves the controller to the UpdateIR state. The falling edge of that same JTCLK latches the data in the instruction shift register to the instruction parallel output. Table 9-1 shows the instructions supported by the DS3106 and their respective operational binary codes. Table 9-1. JTAG Instruction Codes INSTRUCTIONS SAMPLE/PRELOAD BYPASS EXTEST CLAMP HIGHZ IDCODE SELECTED REGISTER Boundary Scan Bypass Boundary Scan Bypass Bypass Device Identification INSTRUCTION CODES 010 111 000 011 100 001 SAMPLE/PRELOAD. SAMPLE/RELOAD is a mandatory instruction for the IEEE 1149.1 specification. This instruction supports two functions. First, the digital I/Os of the device can be sampled at the boundary scan register, using the Capture-DR state, without interfering with the device’s normal operation. Second, data can be shifted into the boundary scan register through JTDI using the Shift-DR state. EXTEST. EXTEST allows testing of the interconnections to the device. When the EXTEST instruction is latched in the instruction register, the following actions occur: (1) Once the EXTEST instruction is enabled through the Update-IR state, the parallel outputs of the digital output pins are driven. (2) The boundary scan register is connected between JTDI and JTDO. (3) The Capture-DR state samples all digital inputs into the boundary scan register. BYPASS. When the BYPASS instruction is latched into the parallel instruction register, JTDI is connected to JTDO through the 1-bit bypass register. This allows data to pass from JTDI to JTDO without affecting the device’s normal operation. IDCODE. When the IDCODE instruction is latched into the parallel instruction register, the device identification register is selected. The device ID code is loaded into the device identification register on the rising edge of JTCLK, following entry into the Capture-DR state. Shift-DR can be used to shift the ID code out serially through JTDO. During Test-Logic-Reset, the ID code is forced into the instruction register’s parallel output. HIGHZ. All digital outputs are placed into a high-impedance state. The bypass register is connected between JTDI and JTDO. CLAMP. All digital output pins output data from the boundary scan parallel output while connecting the bypass register between JTDI and JTDO. The outputs do not change during the CLAMP instruction. 19-4629; Rev 3; 5/09 73 of 87 ____________________________________________________________________________________________ DS3106 9.4 JTAG Test Registers IEEE 1149.1 requires a minimum of two test registers—the bypass register and the boundary scan register. An optional test register, the identification register, has been included in the device design. It is used with the IDCODE instruction and the Test-Logic-Reset state of the TAP controller. Bypass Register. This is a single 1-bit shift register used with the BYPASS, CLAMP, and HIGHZ instructions to provide a short path between JTDI and JTDO. Boundary Scan Register. This register contains a shift register path and a latched parallel output for control cells and digital I/O cells. BSDL files are available at www.maxim-ic.com/TechSupport/telecom/bsdl.htm. Identification Register. This register contains a 32-bit shift register and a 32-bit latched parallel output. It is selected during the IDCODE instruction and when the TAP controller is in the Test-Logic-Reset state. The device identification code for the DS3106 is shown in Table 9-2. Table 9-2. JTAG ID Code DEVICE REVISION DEVICE CODE MANUFACTURER CODE REQUIRED DS3106 Consult factory 0000000010100100 00010100001 1 19-4629; Rev 3; 5/09 74 of 87 ____________________________________________________________________________________________ DS3106 10. Electrical Characteristics ABSOLUTE MAXIMUM RATINGS Voltage Range on Any Pin with Respect to VSS (except VDD)…….………………………………………..-0.3V to +5.5V Supply Voltage Range (VDD) with Respect to VSS…….………….………………………………………..-0.3V to +1.98V Supply Voltage Range (VDDIO) with Respect to VSS…………….………………………………………….-0.3V to +3.63V Ambient Operating Temperature Range………………………………………………………..…-40°C to +85°C (Note 1) Junction Operating Temperature Range…………………………………………………………………..-40°C to +125°C Storage Temperature Range………………………………………………………………………………..-55°C to +125°C Soldering Temperature…………………………………………………………See IPC/JEDEC J-STD-020 Specification Note 1: Specifications to -40C are guaranteed by design and not production tested. Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to the absolute maximum rating conditions for extended periods may affect device. Ambient operating temperature range when device is mounted on a four-layer JEDEC test board with no airflow. Note: The typical values listed in the tables of Section 10 are not production tested. 10.1 DC Characteristics Table 10-1. Recommended DC Operating Conditions PARAMETER Supply Voltage, Core Supply Voltage, I/O Ambient Temperature Range Junction Temperature Range SYMBOL VDD VDDIO TA TJ CONDITIONS MIN 1.62 3.135 -40 -40 TYP 1.8 3.3 MAX 1.98 3.465 +85 +125 UNITS V V °C °C MIN TYP MAX UNITS Table 10-2. DC Characteristics (VDD = 1.8V 10%; VDDIO = 3.3V 5%, TA = -40°C to +85°C) PARAMETER Supply Current, Core Supply Current, I/O Supply Current from VDD_OC6 When Output OC6 Enabled Input Capacitance Output Capacitance SYMBOL CONDITIONS IDD (Notes 2, 3) 151 185 mA IDDIO (Notes 2, 3) 37 50 mA (Note 4) 16 mA CIN 5 pF COUT 7 pF IDDOC6 Note 2: 12.800MHz clock applied to REFCLK and 19.44MHz clock applied to one CMOS/TTL input clock pin. Output clock pin OC3 at 19.44MHz driving 100pF load; all other inputs at VDDIO or grounded; all other outputs disabled and open. Note 3: TYP current measured at VDD = 1.8V and VDDIO = 3.3V, MAX current measured at VDD = 1.98V and VDDIO = 3.465V. Note 4: 19.44MHz output clock frequency, driving the load shown in Figure 10-1. Enabled means MCR8:OC6SF 00. 19-4629; Rev 3; 5/09 75 of 87 ____________________________________________________________________________________________ DS3106 Table 10-3. CMOS/TTL Pins (VDD = 1.8V 10%; VDDIO = 3.3V 5%, TA = -40°C to +85°C) PARAMETER Input High Voltage Input Low Voltage SYMBOL VIH VIL CONDITIONS MIN 2.0 -0.3 TYP MAX 5.5 +0.8 UNITS V V IIL (Note 1) -10 +10 A IILPU (Note 1) -100 +10 A IILPD (Note 1) -10 +100 A Output Leakage (when High-Z) ILO (Note 1) -10 +10 A Output High Voltage (IO = -4.0mA) VOH 2.4 VDDIO 2.0 VDDIOB Output Low Voltage (IO = +4.0mA) VOL 0 0.4 V Input Leakage Input Leakage, Pins with Internal Pullup Resistor (50k typ) Input Leakage, Pins with Internal Pulldown Resistor (50k typ) Note 1: 0V < VIN < VDDIO for all other digital inputs. Note 2: For OC1B to OC5B when VDDIOB = 2.5V. (Note 2) V Table 10-4. LVDS Output Pins (VDD = 1.8V 10%; VDDIO = 3.3V 5%, TA = -40°C to +85°C) PARAMETER Output High Voltage Output Low Voltage Differential Output Voltage Output Offset (Common Mode) Voltage Difference in Magnitude of Output Differential Voltage for Complementary States SYMBOL VOHLVDS VOLLVDS VODLVDS VOSLVDS VDOSLVDS CONDITIONS (Note 1) (Note 1) 25C (Note 1) MIN TYP MAX 1.6 0.9 247 1.125 350 1.25 454 1.375 UNITS V V mV V 25 mV Note 1: With 100 load across the differential outputs. Note 2: The differential outputs can easily be interfaced to LVDS, LVPECL, and CML inputs on neighboring ICs using a few external passive components. See Maxim App Note HFAN-1.0 for details. 19-4629; Rev 3; 5/09 76 of 87 ____________________________________________________________________________________________ DS3106 Table 10-5. LVPECL Level-Compatible Output Pins (VDD = 1.8V 10%; VDDIO = 3.3V 5%, TA = -40°C to +85°C) PARAMETER Differential Output Voltage Output Offset (Common Mode) Voltage Difference in Magnitude of Output Differential Voltage for Complementary States SYMBOL VODPECL VOSPECL CONDITIONS MIN 595 25C (Note 1) TYP 700 0.8 VDOSPECL MAX 930 UNITS mV V 50 mV Note 1: With 100 load across the differential outputs. Note 2: The differential outputs can easily be interfaced to LVDS, LVPECL, and CML inputs on neighboring ICs using a few external passive components. See Maxim App Note HFAN-1.0 for details. Figure 10-1. Recommended Termination for LVDS Output Pins DS3106 OC6POS LVDS OUTPUTS OC6NEG LVDS RECEIVER Figure 10-2. Recommended Termination for LVPECL-Compatible Output Pins 3.3V 82 DS3106 LVPECL LEVELCOMPATIBLE OUTPUTS OC6POS OC6NEG 82 50 50 LVPECL RECEIVER 0.01F 130 130 GND 19-4629; Rev 3; 5/09 77 of 87 ____________________________________________________________________________________________ DS3106 10.2 Input Clock Timing Table 10-6. Input Clock Timing (VDD = 1.8V 10%; VDDIO = 3.3V 5%, TA = -40°C to +85°C.) PARAMETER Input Clock Duty Cycle SYMBOL CONDITIONS MIN 30 TYP MAX 70 UNITS % 10.3 Output Clock Timing Table 10-7. Input Clock to Output Clock Delay INPUT FREQUENCY OUTPUT FREQUENCY 8kHz 6.48MHz 19.44MHz 25.92MHz 38.88MHz 51.84MHz 77.76MHz 155.52MHz 8kHz 6.48MHz 19.44MHz 25.92MHz 38.88MHz 51.84MHz 77.76MHz 155.52MHz INPUT CLOCK EDGE TO OUTPUT CLOCK EDGE DELAY (ns) 0 1.5 0 1.5 0 1.5 0 1.5 0 1.5 0 1.5 0 1.5 0 1.5 Table 10-8. Output Clock Phase Alignment, Frame-Sync Alignment Mode OUTPUT FREQUENCY 8kHz (FSYNC) 2kHz 8kHz 1.544MHz 2.048MHz 44.736MHz 34.368MHz 6.48MHz 19.44MHz 25.92MHz 38.88MHz 51.84MHz 77.76MHz 155.52MHz 311.04MHz 19-4629; Rev 3; 5/09 MFSYNC FALLING EDGE TO OUTPUT CLOCK FALLING EDGE DELAY (ns) 0 0.5 0 0.5 0 0.5 0 1.25 0 1.25 -2.0 1.25 -2.0 1.25 -2.0 1.25 -2.0 1.25 -2.0 1.25 -2.0 1.25 -2.0 1.25 -2.0 1.25 -2.0 1.25 -2.0 1.25 78 of 87 ____________________________________________________________________________________________ DS3106 10.4 SPI Interface Timing Table 10-9. SPI Interface Timing (VDD = 1.8V 10%; VDDIO = 3.3V 5%, TA = -40°C to +85°C.) (See Figure 10-3.) PARAMETER (Note 1) SYMBOL MIN TYP MAX UNITS 6 MHz SCLK Frequency fBUS SCLK Cycle Time tCYC 100 ns CS Setup to First SCLK Edge tSUC 15 ns CS Hold Time After Last SCLK Edge tHDC 15 ns SCLK High Time tCLKH 50 ns SCLK Low Time tCLKL 50 ns SDI Data Setup Time tSUI 5 ns SDI Data Hold Time tHDI 15 ns SDO Enable Time (High-Z to Output Active) tEN 0 ns SDO Disable Time (Output Active to High-Z) tDIS 25 ns SDO Data Valid Time tDV 50 ns SDO Data Hold Time After Update SCLK Edge tHDO Note 1: 5 ns All timing is specified with 100pF load on all SPI pins. 19-4629; Rev 3; 5/09 79 of 87 ____________________________________________________________________________________________ DS3106 Figure 10-3. SPI Interface Timing Diagram CPHA = 0 CS tSUC tHDC tCYC tCLKL SCLK, CPOL=0 tCLKH tCLKL SCLK, CPOL=1 tSUI tCLKH tHDI SDI tDV tDIS SDO tEN tHDO CPHA = 1 CS tSUC SCLK, CPOL=0 SCLK, CPOL=1 tHDC tCYC tCLKL tCLKH tCLKL tSUI tCLKH tHDI SDI tDV tDIS SDO tEN 19-4629; Rev 3; 5/09 tHDO 80 of 87 ____________________________________________________________________________________________ DS3106 10.5 JTAG Interface Timing Table 10-10. JTAG Interface Timing (VDD = 1.8V 10%; VDDIO = 3.3V 5%, TA = -40°C to +85°C.) (See Figure 10-4.) PARAMETER JTCLK Clock Period SYMBOL t1 MIN TYP 1000 t2/t3 50 500 JTCLK to JTDI, JTMS Setup Time t4 50 ns JTCLK to JTDI, JTMS Hold Time t5 50 ns JTCLK to JTDO Delay t6 2 50 ns JTCLK to JTDO High-Z Delay (Note 2) t7 2 50 ns JTRST Width Low Time t8 100 JTCLK Clock High/Low Time (Note 1) Note 1: Clock can be stopped high or low. Note 2: Not tested during production test. MAX UNITS ns ns ns Figure 10-4. JTAG Timing Diagram t1 t3 t2 JTCLK t4 t5 JTDI, JTMS, JTRST t6 t7 JTDO JTRST 19-4629; Rev 3; 5/09 t8 81 of 87 ____________________________________________________________________________________________ DS3106 10.6 Reset Pin Timing Table 10-11. Reset Pin Timing (VDD = 1.8V 10%; VDDIO = 3.3V 5%, TA = -40°C to +85°C.) (See Figure 10-5.) PARAMETER SYMBOL MIN RST Low Time (Note 1) t1 1000 ns SONSDH, IPF[2:0], O3F[2:0], O6F[2:0] Setup Time to RST t2 0 ns SONSDH, IPF[2:0], O3F[2:0], O6F[2:0] Hold Time from RST t3 50 ns Note 1: TYP MAX UNITS RST should be held low while the REFCLK oscillator stabilizes. It is recommended to force RST low during power-up. The 1000ns minimum time applies if the RST pulse is applied any time after the device has powered up and the oscillator has stabilized. Figure 10-5. Reset Pin Timing Diagram t1 RST t2 SONSDH OxF[2:0] IPF[2:0] 19-4629; Rev 3; 5/09 X t3 VALID X 82 of 87 ____________________________________________________________________________________________ DS3106 11. Pin Assignments Table 11-1 lists pin assignments sorted in alphabetical order by pin name. Figure 11-1 shows pin assignments arranged by pin number. Table 11-1. Pin Assignments Sorted by Signal Name PIN NAME PIN NUMBER PIN NAME PIN NUMBER AVDD_DL AVDD_PLL1 AVDD_PLL2 AVDD_PLL3 AVDD_PLL4 AVSS_DL AVSS_PLL1 AVSS_PLL2 AVSS_PLL3 AVSS_PLL4 CPHA CS FSYNC IC3 IC4 IPF0 IPF1 IPF2 INTREQ/LOS JTCLK JTDI JTDO 59 4 7 9 11 55 3 8 10 12 42 44 17 29 30 28 33 34 5 49 51 50 N.C. O3F0 MFSYNC O3F1/SRFAIL O3F2/LOCK O6F0/GPIO1 O6F1/GPIO2 O6F2/GPIO3 OC3 OC6NEG OC6POS REFCLK RST SCLK SDI SDO SONSDH/GPIO4 SRCSW TEST VDD VDDIO VDD_OC6 JTMS 41 VSS JTRST 37 VSS_OC6 23–26 35 18 38 36 45 46 63 56 20 19 6 48 47 43 52 64 13 2 27, 39, 57, 58 14, 32, 54, 61 22 1, 15, 16, 31, 40, 53, 60, 62 21 19-4629; Rev 3; 5/09 83 of 87 ____________________________________________________________________________________________ DS3106 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 DS3106 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 RST SCLK O6F1/GPIO2 O6F0/GPIO1 CS SDI CPHA JTMS VSS VDD O3F1/SRFAIL JTRST O3F2/LOCK O3F0 IPF2 IPF1 FSYNC MFSYNC OC6POS OC6NEG VSS_OC6 VDD_OC6 NC NC NC NC VDD IPF0 IC3 IC4 VSS VDDIO 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 VSS TEST AVSS_PLL1 AVDD_PLL1 INTREQ/LOS REFCLK AVDD_PLL2 AVSS_PLL2 AVDD_PLL3 AVSS_PLL3 AVDD_PLL4 AVSS_PLL4 SRCSW VDDIO VSS VSS 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 SONSDH/GPIO4 O6F2/GPIO3 VSS VDDIO VSS AVDD_DL VDD VDD OC3 AVSS_DL VDDIO VSS SDO JTDI JTDO JTCLK Figure 11-1. Pin Assignment Diagram 19-4629; Rev 3; 5/09 84 of 87 ____________________________________________________________________________________________ DS3106 12. Package Information For the latest package outline information and land patterns, go to www.maxim-ic.com/packages. 13. PACKAGE TYPE PACKAGE CODE DOCUMENT NO. 64 LQFP — 21-0083 Thermal Information Table 13-1. LQFP Package Thermal Properties, Natural Convection PARAMETER Ambient Temperature (Note 1) Junction Temperature Theta-JA (JA) (Note 2) Psi-JB Psi-JT MIN -40C -40C TYP MAX +85C +125C 45.4C/W 23.8C/W 0.3C/W Note 1: The package is mounted on a four-layer JEDEC standard test board with no airflow and dissipating maximum power. Note 2: Theta-JA (JA) is the junction to ambient thermal resistance, when the package is mounted on a four-layer JEDEC standard test board with no airflow and dissipating maximum power. Table 13-2. LQFP Theta-JA (JA) vs. Airflow FORCED AIR (METERS PER SECOND) 0 1 2.5 19-4629; Rev 3; 5/09 THETA-JA (JA) 45.4C/W 37.3C/W 34.5C/W 85 of 87 ____________________________________________________________________________________________ DS3106 14. Acronyms and Abbreviations AIS AMI APLL BITS BPV DFS DPLL ESF EXZ GbE I/O LOS LVDS LVPECL MTIE OCXO OOF PBO PFD PLL ppb ppm pk-pk RMS RAI RO R/W SDH SEC SETS SF SONET SSM SSU STM TDEV TCXO UI UIP-P XO Alarm Indication Signal Alternate Mark Inversion Analog Phase-Locked Loop Building Integrated Timing Supply Bipolar Violation Digital Frequency Synthesis Digital Phase-Locked Loop Extended Superframe Excessive Zeros Gigabit Ethernet Input/Output Loss of Signal Low-Voltage Differential Signal Low-Voltage Positive Emitter-Coupled Logic Maximum Time Interval Error Oven-Controlled Crystal Oscillator Out of Frame Alignment Phase Build-Out Phase/Frequency Detector Phase-Locked Loop Parts per Billion Parts per Million Peak-to-Peak Root-Mean-Square Remote Alarm Indication Read-Only Read/Write Synchronous Digital Hierarchy SDH Equipment Clock Synchronous Equipment Timing Source Superframe Synchronous Optical Network Synchronization Status Message Synchronization Supply Unit Synchronous Transport Module Time Deviation Temperature-Compensated Crystal Oscillator Unit Interval Unit Interval, Peak-to-Peak Crystal Oscillator 19-4629; Rev 3; 5/09 86 of 87 ____________________________________________________________________________________________DS3106 15. Data Sheet Revision History REVISION NUMBER REVISION DATE 0 121407 Initial data sheet release. — 1 100108 In Section 7.7.8, corrected the PLL bandwidth range to have the correct range of 18Hz to 400Hz to match the register descriptions for T0ABW and T0LBW 24 2 030909 Corrected several frequencies in Table 7-16 and Table 7-17 to match actual device operation. 3 5/09 DESCRIPTION In Section 8, added note indicating systems must be able to access entire address range 0-1FFh. 19-4629; Rev 3; 5/09 PAGES CHANGED 32, 33 37 87 of 87 Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied. Maxim reserves the right to change the circuitry and specifications without notice at any time. Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600 2009 Maxim Integrated Products Maxim is a registered trademark of Maxim Integrated Products.