Data Delay MDU3C-20 Triple, hcmos-interfaced fixed delay line (series mdu3c) Datasheet

MDU3C
data 3 
delay
devices, inc.
TRIPLE, HCMOS-INTERFACED
FIXED DELAY LINE
(SERIES MDU3C)
FEATURES
•
•
•
•
•
•
PACKAGES
Three independent delay lines
Fits standard 14-pin DIP socket
Low profile
Auto-insertable
Input & outputs fully CMOS interfaced & buffered
2
10 T L fan-out capability
I1
1
14
VDD
I2
3
12
O1
I3
5
10
O3
GND
7
8
O5
MDU3C-xx
MDU3C-xxA2
MDU3C-xxB2
MDU3C-xxM
I1
N/C
I2
N/C
I3
N/C
GND
1
2
3
4
5
6
7
14
13
12
11
10
9
8
VDD
N/C
O1
N/C
O2
N/C
O3
Military SMD
MDU3C-xxMC2
DIP
Gull-Wing
J-Lead
Military DIP
FUNCTIONAL DESCRIPTION
PIN DESCRIPTIONS
The MDU3C-series device is a 3-in-1 digitally buffered delay line. The
signal inputs (I1-I3) are reproduced at the outputs (O1-O3), shifted in time
by an amount determined by the device dash number (See Table). The
delay lines function completely independently of each other.
I1-I3
O1-O3
VDD
GND
SERIES SPECIFICATIONS
•
•
•
•
•
•
DASH NUMBER SPECIFICATIONS
Minimum input pulse width: 100% of total delay
Output rise time: 8ns typical
Supply voltage: 5VDC ± 5%
Supply current: ICCL = 40µa typical
ICCH = 60ma typical
Operating temperature: 0° to 70° C
Temp. coefficient of total delay: 300 PPM/°C
O1
O2
Signal Inputs
Signal Outputs
+5 Volts
Ground
O3
Part
Number
MDU3C-10
MDU3C-15
MDU3C-20
MDU3C-25
MDU3C-30
MDU3C-40
MDU3C-50
MDU3C-60
MDU3C-75
MDU3C-100
Delay Per
Line (ns)
10 ± 2.0
15 ± 2.0
20 ± 2.0
25 ± 2.0
30 ± 2.0
40 ± 2.0
50 ± 2.5
60 ± 3.0
75 ± 3.7
100 ± 5.0
NOTE: Any dash number between 10 and 100
not shown is also available.
VCC
100%
100%
100%
I1
I2
I3
GND
Functional block diagram
 1997 Data Delay Devices
Doc #97039
12/12/97
DATA DELAY DEVICES, INC.
3 Mt. Prospect Ave. Clifton, NJ 07013
1
MDU3C
APPLICATION NOTES
Delay Devices if your application requires device
testing at a specific input condition.
HIGH FREQUENCY RESPONSE
The MDU3C tolerances are guaranteed for input
pulse widths and periods greater than those
specified in the test conditions. Although the
device will function properly for pulse widths as
small as 100% of the total delay and periods as
small as 200% of the total delay (for a symmetric
input), the delays may deviate from their values at
low frequency. However, for a given input
condition, the deviation will be repeatable from
pulse to pulse. Contact technical support at Data
POWER SUPPLY BYPASSING
The MDU3C relies on a stable power supply to
produce repeatable delays within the stated
tolerances. A 0.1uf capacitor from VDD to GND,
located as close as possible to the VDD pin, is
recommended. A wide VDD trace and a clean
ground plane should be used.
DEVICE SPECIFICATIONS
TABLE 1: ABSOLUTE MAXIMUM RATINGS
PARAMETER
DC Supply Voltage
Input Pin Voltage
Storage Temperature
Lead Temperature
SYMBOL
VDD
VIN
TSTRG
TLEAD
MIN
-0.3
-0.3
-55
MAX
7.0
VDD+0.3
150
300
UNITS
V
V
C
C
NOTES
10 sec
TABLE 2: DC ELECTRICAL CHARACTERISTICS
(0C to 70C, 4.75V to 5.25V)
PARAMETER
High Level Output Voltage
SYMBOL
VOH
Low Level Output Voltage
VOL
High Level Output Current
Low Level Output Current
High Level Input Voltage
Low Level Input Voltage
Input Current
IOH
IOL
VIH
VIL
IIH
Doc #97039
12/12/97
MIN
3.98
TYP
4.4
MAX
UNITS
V
0.15
0.26
V
-4.0
4.0
mA
mA
V
V
µA
3.15
1.35
0.10
NOTES
VDD = 5.0, IOH = MAX
VIH = MIN, VIL = MAX
VDD = 5.0, IOL = MAX
VIH = MIN, VIL = MAX
VDD = 5.0
DATA DELAY DEVICES, INC.
Tel: 973-773-2299
Fax: 973-773-9672
http://www.datadelay.com
2
MDU3C
PACKAGE DIMENSIONS
14
12
10
8
Lead Material:
Nickel-Iron alloy 42
TIN PLATE
14
12
3
5
8
.410
TYP.
1
1
10
3
5
7
7
.280
MAX.
.780 MAX.
.820 MAX.
.290
MAX.
.020 .320
TYP. MAX.
.130
±.030
.015 TYP.
.010±.002
.018
TYP.
.070 MAX.
.350
MAX.
.600±.010
14
12
.040
TYP.
10
.010 TYP.
1
3
.090
5
8
14
12
7
.050
TYP.
MDU3C-xxA2 (Commercial Gull-Wing)
.020 TYP.
9
3
.110
2
.090
3
4
5
6
.100
.600
.780±.020
7
.200
.600
.790 MAX.
.350
MAX.
.110
TYP.
.010±.002
8
.882
±.005
.710 .590
±.005 MAX.
1
5
MDU3C-xxB2 (Commercial J-Lead)
.040
TYP.
14 13 12 11 10
.320
TYP.
.270
TYP.
1
.300
MAX.
.050 TYP.
8
10
.430
TYP.
.200
.600
.790 MAX.
.300
TYP.
.040
TYP.
.020 TYP.
.270
TYP.
.020 TYP.
MDU3C-xxM (Military DIP)
MDU3C-xx (Commercial DIP)
.020 TYP.
.200
TYP.
.018 TYP.
.600 TYP.
.007
±.005
7
.280
MAX.
.050
±.010
MDU3C-xxMC2 (Military SMD)
Doc #97039
12/12/97
DATA DELAY DEVICES, INC.
3 Mt. Prospect Ave. Clifton, NJ 07013
3
MDU3C
DELAY LINE AUTOMATED TESTING
TEST CONDITIONS
INPUT:
o
o
Ambient Temperature: 25 C ± 3 C
Supply Voltage (VDD): 5.0V ± 0.1V
Input Pulse:
High = 5.0V ± 0.1V
Low = 0.0V ± 0.1V
Source Impedance:
50Ω Max.
Rise/Fall Time:
5.0 ns Max. (measured
between 0.5V and 4.5V )
Pulse Width:
PWIN = 1.5 x Total Delay
Period:
PERIN = 10 x Total Delay
OUTPUT:
Load:
Cload:
Threshold:
1 FAST-TTL Gate
5pf ± 10%
2.5V (Rising & Falling)
NOTE: The above conditions are for test only and do not in any way restrict the operation of the device.
PRINTER
COMPUTER
SYSTEM
REF
PULSE
GENERATOR
OUT
I1
TRIG
I2
DEVICE UNDER
TEST (DUT)
I3
O1
IN
O2
TRIG
TIME INTERVAL
COUNTER
O3
Test Setup
PERIN
PWIN
TRISE
INPUT
SIGNAL
TFALL
VIH
4.5V
2.5V
0.5V
4.5V
2.5V
0.5V
TRISE
VIL
TFALL
VOH
OUTPUT
SIGNAL
2.5V
2.5V
VOL
Timing Diagram For Testing
Doc #97039
12/12/97
DATA DELAY DEVICES, INC.
Tel: 973-773-2299
Fax: 973-773-9672
http://www.datadelay.com