Renesas ISL5416EVAL1 Four-channel wideband programmable downconverter Datasheet

DATASHEET
ISL5416
FN6006
Rev 3.00
Aug 2004
Four-Channel Wideband Programmable DownConverter
The ISL5416 Four-Channel Wideband Programmable Digital
DownConverter (WPDC) is designed for high dynamic range
applications such as cellular basestations where the
processing of multiple channels is required in a small
physical space. The WPDC combines four channels in a
single package, each including: an NCO, a digital mixer,
digital filters, an AGC and a resampling filter.
Features
• Up to 95MSPS Input
• Four Parallel 16-bit Fixed or 17-bit Floating Point Inputs
• Programmable RF Attenuator/VGA Control
• 32-Bit Programmable Carrier NCO with > 110dB SFDR
• 20-bit Internal Data Path
All channels are independently programmable and may be
updated in real time. Each of the four channels can select
any of the four digital input buses. Each of the tuners can
process a W-CDMA channel. Channels may be cascaded or
polyphased for increased bandwidth. Selectable outputs
include I samples, Q samples, and AGC gain. Outputs from
the part are available over the parallel, serial or uP
interfaces.
• Filter Functions
- Multi-Stage Cascaded-Integrator-Comb (CIC) Filter
- Two programmable FIR Filters (first up to 32-taps,
second up to 64-taps)
- Half Band Interpolation Filter
- Resampling FIR Filter
• Overall decimation from 1 to >4096
Ordering Information
• Digital AGC with up to 96dB of Gain Range
PART
NUMBER
TEMP
RANGE (oC)
PACKAGE
• Up to Four Independent 16-bit Parallel Outputs
PKG. DWG. #
ISL5416KI
-40 to 85
256 BGA
V256.17x17
• Serial Output Option
ISL5416KIZ
(See Note)
-40 to 85
256 BGA
(Pb-free)
V256.17x17
• 16-bit Parallel P Interface
ISL5416EVAL1
25
• 1.8V core, 3.3V I/O Operation
EVALUATION KIT
• Evaluation Board and Configuration Software available
NOTE: Intersil Pb-free products employ special Pb-free material sets; molding
compounds/die attach materials and 100% matte tin plate termination finish, which is
compatible with both SnPb and Pb-free soldering operations. Intersil Pb-free
products are MSL classified at Pb-free peak reflow temperatures that meet or exceed
the Pb-free requirements of IPC/JEDEC J Std-020B.
• Pb-free available
Applications
• Basestation Receivers: GSM/EDGE, CDMA2000, UMTS.
Block Diagram
TEST
REGISTER
Q
CHANNEL O
CHANNEL 1
CHANNEL 2
FN6006 Rev 3.00
Aug 2004
CHANNEL 3
SYNCO SYNCIN1 SYNCIN2
AOUT(7:0)
FSYNCA
OEA
CLKO1
CLKO2
/INTRPT
P INTERFACE
SYNCHRONIZATION
CE
JTAG
P(15:0)
RESET
RF ATTENUATOR
VGA CONTROL
Q
Q
INPUT D
EOUT(15:0)
RESAMPLER
IHBF
AGC
Q
I
I
OUTPUT ROUTING & FORMATTING
Q
FIR2
FILTER
I
WR or
DSTRB
INPUT C
FIR1
FILTER
I
RD or
RD/WR
INPUT B
NCO
MIXER
CIC
Q
I
uP MODE
INPUT A
AOUT(15:8)
I
ADD(2:0)
INPUT
SELECT
CLOCK &
FORMAT
INPUT CHANNEL ROUTING
AIN(16:0)
ENIA
CLKA
RANGE CONTROL
OUTPUT
Page 1 of 71
TO SERIAL TO PARALLEL
TO uP
SEQUENCING
INTERFACE ROUTING
AND ROUTING
FILTER
CASCADE
OUTPUT
32-BIT CONTROL
>110 db SFDR
ENIA
CLKA
INPUT
FORMAT
RANGE
CONTROL
1-64 TAPS
R=1-8
BYPASS
24
/
24
/
F
I
F
O
16
16
16
/ IHBF / RESAMPLING /
16
16
16
FILTER
/
/
/
SELECT
FORMAT
AGC
MUX
24
20
GAIN / FIR /
20 2 24
/
/
/
24
R
O 16
/
U 16
N /
D
CHANNEL 0
CASCADE
IN
MUX
AIN(16:0)
1-32 TAPS
R=1-8
BYPASS
TEST
REGISTER
INPUT A
24
/
24
/
24
/
0 - 96 dB
BYPASS
1-5 STAGES
R=2-64K
BYPASS
24
20
/ GAIN / FIR
24
20 1
/
/
x1, 2, 4, 8
ROUND
SATURATE
NCO
CIC
24
FILTER /
24
/
x1, 2, 4, 8
ROUND
SATURATE
DIGITAL 24
16 TUNING /
/
MIXER 24
/
MUX
AIN(16:0)
BIN(16:0)
CIN(16:0)
DIN(16:0)
TEST INPUT
MUX
CASCADE
INPUTS
ISL5416
FN6006 Rev 3.00
Aug 2004
TYPICAL CHANNEL
AOUT(15:0)
DIGITAL
TUNER
OUTPUT
FORMAT
FSYNCA
SLOT CONTROL
CH 0, 1 MUXING
OEA
EXT AGC CNTRL
CASCADE
OUT
CLKB
BOUT(15:0)
INPUT
FORMAT
RANGE
CONTROL
DIGITAL
TUNER
OUTPUT
FORMAT
SLOT CONTROL
CH 0, 1 MUXING
CHANNEL 2
INPUT C
ENIC
CLKC
INPUT
FORMAT
MUX
CIN(16:0)
RANGE
CONTROL
CLKD
SLOT CONTROL
CH 2, 3 MUXING
RANGE
CONTROL
DIGITAL
TUNER
OUTPUT
FORMAT
SLOT CONTROL
CH 2, 3 MUXING
Page 2 of 71
MUX
SERIAL OUTPUTS
EOUT(15:0)
RESET
OEB
COUT(15:0)
FSYNCC
OEC
DOUT(15:0)
INPUT
FORMAT
MUX
ENID
OUTPUT
FORMAT
FSYNCB
CHANNEL 3
AGC GAIN
INPUT D
DIN(16:0)
DIGITAL
TUNER
OUTPUT MULTIPLEXING
ENIB
MUX
BIN(16:0)
MUX
CHANNEL 1
AGC GAIN
TRST
TMS
TCLK
TDI
TDO
SEQUENCED uP READ DATA
JTAG
SYNCHRONIZATION
uP INTERFACE
P(15:0), uPMODE, RD (RD/WR),
WR (DSTRB), CE, ADD(2:0)
SYNCO SYNCIN1 SYNCIN2
FSYNCD
OED
CLKO1
CLKO2/
INTRPT
ISL5416
INPUT B
ISL5416
256-LEAD BGA
TOP VIEW
1
2
3
4
5
6
7
8
9
10
11
Ain9
ENIA
Ain10
Ain11
Ain12
Ain14
Eout13
CLKA SYNCIn1 SYNCO Aout15 Aout14 Aout13
Ain8
Bin9
Vcc
Ain15
Ain16
Eout15
GND SYNCIn2
OEA
Ain7
Bin8
ENIB
Bin11
Bin12
Ain13
Bin16
CLKB
P15
VccIO
OEB
Ain6
Bin6
Bin7
GND
Bin14
Bin15
Eout12 Eout14
P14
P12
Ain5
Ain4
Bin4
Bin5
Eout10 Bin13 Eout11
Ain3
RESET
Vcc
Bin3
GND
Ain2
Ain1
Bin1
Bin2
TMS
Vcc
Eout6
12
13
15
14
16
A
GND
Aout12 Aout11
B
Vcc
Bin10
Vcc
Bout13 Bout12 Bout11 FSYNCA
C
VccIO FSYNCB VccIO Bout10 Aout10
D
Bout15 Bout14
Bout8
Bout9 Aout8
Aout9
GND
Bout6
Bout7 Aout6
Aout7
Bout5
Bout4
VccIO
Aout4
Aout5
Aout3
Vcc
Aout1
Aout2
E
Vcc
P13
P11
TDO
uPmode
GND
P10
P9
F
GND
GND
G
TDI
P8
Eout8
Eout9
Eout7
GND
Bout3
GND
P7
Bout1
GND
GND
P5
P3
P4
Dout15 CLKO2/ CLKO1 Cout15
INTRPT
H
Ain0
Bin0
Bout2
J
CLKC
VccIO
CLKD
GND
Cin16
Din16
Eout4
Eout5
Eout2
Cin14
Cin15
Eout3
Din15
Din14
TRST
Add2
GND
Add1
GND
P2
Vcc
Dout13 Dout14 Cout14 Cout13
Cin12
Cin13
Din12
Din13
GND
GND
WR
RD
Vcc
P0
Dout3
Add0
Dout11 Dout12 Cout12 Cout11
Cin10
Cin11
Din10
Din11
Din4
Din3
Vcc
Din0
Dout0
P1
OED
Dout4
GND
VccIO Dout10 Cout10
Cin9
Din9
Vcc
Din6
ENID
Din2
Din1
Eout1
Dout1
Dout2
Vcc
Dout5
Dout6
Dout7
GND
Din8
Din7
Din5
ENIC
Cin2
CE
Eout0
Cout0
Cout2
OEC
Cout4
VccIO FSYNCD Dout8
Cout9
Cin8
Cin7
Cin6
Cin5
Cin4
Cin3
Cin1
Cin0
Cout1
TCLK
Cout3
Cout5
Cout6 FSYNCC Cout7
Cout8
P6
Bout0
VccIO Aout0
K
L
M
N
P
Dout9
GND
R
T
POWER PIN
SIGNAL PIN
GROUND PIN
THERMAL BALL
NC (NO CONNECTION)
Vcc = +1.8V CORE SUPPLY VOLTAGE
VccIO = +3.3V I/O SUPPLY VOLTAGE
NOTE: Thermal Balls should be connected to the ground plane
Unused Input Balls should be connected to ground or VccIO as appropriate
FN6006 Rev 3.00
Aug 2004
Page 3 of 71
ISL5416
Pin Descriptions
NAME
TYPE
INTERNAL
PULL-UP/DOWN
DESCRIPTION
POWER SUPPLY
Vcc
-
Positive Power Supply Voltage (core), 1.8V 0.09
VccIO
-
Positive Power Supply Voltage (I/O), 3.3V 0.165
GND
-
Ground, 0V.
INPUTS
Ain(16:0)
I
PULL DOWN
Parallel Data Input bus A. Sampled on the rising or falling edge (programmable) of clock when ENIA
is active (low). The bus order can be programmed (See IWA = 0*00h, bit 4).
Bin(16:0)
I
PULL DOWN
Parallel Data Input bus B. Sampled on the rising or falling edge (programmable) of clock when ENIB
is active (low). The bus order can be programmed (See IWA = 0*00h, bit 4).
Cin(16:0)
I
PULL DOWN
Parallel Data Input bus C. Sampled on the rising or falling edge (programmable) of clock when ENIC
is active (low). The bus order can be programmed (See IWA = 0*00h, bit 4).
Din(16:0)
I
PULL DOWN
Parallel Data Input bus D. Sampled on the rising or falling edge (programmable) of clock when ENID
is active (low). The bus order can be programmed (See IWA = 0*00h, bit 4).
ENIA
I
PULL DOWN
Input enable for Parallel Data Input bus A. Active low. This pin enables the input to the part in one of
two modes, gated or interpolated. In gated mode, one sample is taken per CLK when ENIx is
asserted.
ENIB
I
PULL DOWN
Input enable for Parallel Data Input bus B. Active low. This pin enables the input to the part in one of
two modes, gated or interpolated. In gated mode, one sample is taken per CLK when ENIx is
asserted.
ENIC
I
PULL DOWN
Input enable for Parallel Data Input bus C. Active low. This pin enables the input to the part in one of
two modes, gated or interpolated. In gated mode, one sample is taken per CLK when ENIx is
asserted.
ENID
I
PULL DOWN
Input enable for Parallel Data Input bus D. Active low. This pin enables the input to the part in one of
two modes, gated or interpolated. In gated mode, one sample is taken per CLK when ENIx is
asserted.
CLKA
I
PULL DOWN
Input clock for data bus A. CLKA or CLKC may be used for Ain(16:0).
CLKB
I
PULL DOWN
Input clock for data bus B. CLKB or CLKC may be used for Bin(16:0).
CLKC
I
CLKD
I
PULL DOWN
Input clock for data bus D. CLKD or CLKC may be used for Din(16:0).
SYNCIn1
I
PULL DOWN
Global synchronization input signal 1. SYNCIn1 can update the carrier NCOs, reset decimation
counters, restart the filter, and restart the output section among other functions. For most of the
functional blocks, the response to SYNCIn1 is programmable and can be enabled or disabled.
SYNCIn2
I
PULL DOWN
Global synchronization input signal 2. SYNCIn2 can update the carrier NCOs, reset decimation
counters, restart the filter, and restart the output section among other functions. For most of the
functional blocks, the response to SYNCIn2 is programmable and can be enabled or disabled.
SYNCO
O
RESET
I
CONTROL
FN6006 Rev 3.00
Aug 2004
Input clock for data bus C. CLKC is also the master clock for all channels of ISL5416
Synchronization Output Signal. The processing of multiple ISL5416 devices can be synchronized by
tying the SYNCO from one ISL5416 device (the master) to the SYNCIn of all the ISL5416 devices
(the master and slaves). An optional internal SYNCO to SYNCInX connection is provided.
PULL UP
Reset Signal. Active low. Asserting reset will halt all processing and set certain registers to default
values.
Page 4 of 71
ISL5416
Pin Descriptions
NAME
TYPE
(Continued)
INTERNAL
PULL-UP/DOWN
DESCRIPTION
JTAG
TDO
O
Test data out
TDI
I
PULL UP
Test data in.
TMS
I
PULL UP
Test mode select.
TCLK
I
PULL DOWN
TRST
I
PULL UP
Test clock.
Test reset. Active low. If JTAG not used, tie this pin low. If there is a trace connected to the pin and
there is enough board noise, the JTAG port might get into an unexpected state and stop
communications with the part
OUTPUTS
Aout(15:0)
O
Parallel Data Output bus A. A 16-bit parallel data output which can be programmed to consist of I, Q,
AGC. Data from Channels 0, 1, 2 and 3 can be multiplexed into a common parallel output data bus.
Information can be sequenced in a programmable order. Can be ones complemented. Can be
divided into two 8-bit busses. See Data Output Formatter Section and Microprocessor Interface
Section. See Table 24.
Bout(15:0)
O
Parallel Data Output bus B. A 16-bit parallel data output which can be programmed to consist of I, Q,
AGC. Data from Channels 0, 1, 2 and 3 can be multiplexed into a common parallel output data bus.
Information can be sequenced in a programmable order. Can be ones complemented. Can be
divided into two 8-bit busses. See Data Output Formatter Section and Microprocessor Interface
Section.
Cout(15:0)
O
Parallel Data Output bus C. A 16-bit parallel data output which can be programmed to consist of I, Q,
AGC. Data from Channels 0, 1, 2 and 3 can be multiplexed into a common parallel output data bus.
Information can be sequenced in a programmable order. Can be ones complemented. Can be
divided into two 8-bit busses. See Data Output Formatter Section and Microprocessor Interface
Section.
Dout(15:0)
O
Parallel Data Output bus D. A 16-bit parallel data output which can be programmed to consist of I, Q,
AGC. Data from Channels 0, 1, 2 and 3 can be multiplexed into a common parallel output data bus.
Information can be sequenced in a programmable order. Can be ones complemented. Can be
divided into two 8-bit busses. See Data Output Formatter Section and Microprocessor Interface
Section.
Below is the table of the serial output bits allocation for DOUT.
SERIAL OUTPUT BITS ALLOCATION
SER. OUTPUT A SER. OUTPUT B SER. OUTPUT C SER. OUTPUT D
SCLKX *
DOUT0
DOUT4
DOUT8
DOUT12
SSYNCX *
DOUT1
DOUT5
DOUT9
DOUT13
SD1X *
DOUT2
DOUT6
DOUT10
DOUT14
SD2X *
DOUT3
DOUT7
DOUT11
DOUT15
* X denotes A, B, C, D as appropriate
Eout(15:0)
O
A 16-bit parallel VGA/Attenuator control output. Partitionable into separate 4 or 8-bit busses.
CLKO1
O
Output Clock 1. Can be programmed to be at CLKC/N for N = 1 to 16. The polarity of CLKO1 is
programmable.
CLKO2/
INTRPT
O
Available ONLY on Rev B (final) version of the part. Provides a complementary output or a second
clock to simplify board routing. Polarity is programmable. It can also be programmed as an interrupt
from one or more channels for a sequenced read (FIFO-like) mode. See register GWA = 0000h, bit
13.
FN6006 Rev 3.00
Aug 2004
Page 5 of 71
ISL5416
Pin Descriptions
(Continued)
INTERNAL
PULL-UP/DOWN
NAME
TYPE
DESCRIPTION
FSYNCA
O
Frame Synchronization output signal for bus Aout(15:0).
FSYNCB
O
Frame Synchronization output signal for bus Bout(15:0).
FSYNCC
O
Frame Synchronization output signal for bus Cout(15:0).
FSYNCD
O
Frame Synchronization output signal for bus Dout(15:0).
OEA
I
PULL UP
Output three-state enable for Parallel Data Output bus A. Active low.
OEB
I
PULL UP
Output three-state enable for Parallel Data Output bus B. Active low.
OEC
I
PULL UP
Output three-state enable for Parallel Data Output bus C. Active low.
OED
I
PULL UP
Output three-state enable for Parallel Data Output bus D. Active low.
MICROPROCESSOR INTERFACE
P(15:0)
I/O
ADD(2:0)
I
Microprocessor Interface Address bus. ADD2 is the MSB. See Microprocessor Interface Section.
WR
or
DSTRB
I
Microprocessor Interface Write or Data Strobe Signal. When the Microprocessor Interface Mode
Control (P MODE) is low, data transfers (from P(15:0) to the internal write holding register) occur on
the low to high transition of WR when CE is asserted (low). When the P MODE control is high this
input functions as a data strobe DSTRB control. In this mode with RD/WR low, data transfers (from
P(15:0) to the internal write holding register) occur on the low to high transition of DSTRB. With
RD/WR high the data from the address specified is placed on P(15:0) when DSTRB is low. See the
Microprocessor Interface Section.
RD
or
RD/WR
I
Microprocessor Interface Read or Read/Write Signal. When the Microprocessor Interface Mode
Control (P MODE) is low, the data from the address specified is placed on P(15:0) when RD is
asserted (low) and CE is asserted (low). When the P MODE control is high this input functions as
a Read/Write control input. Data is read from P(15:0) when RD/WR high or written to the
appropriate register when low. See the Microprocessor Interface Section.
P MODE
I
CE
I
FN6006 Rev 3.00
Aug 2004
Microprocessor Interface Data bus. See Microprocessor Interface Section. P15 is the MSB.
PULL DOWN
Microprocessor Interface Mode Control. This pin is used to select the Read/Write mode for the
Microprocessor Interface. When 0, RD and WR, when 1, DSTROBE and RD/WR. When P MODE
is 0, the microprocessor interface consists of separate RD and WR strobes; when P MODE is 1, the
interface consists of a RD/WR control and a single data strobe. See the Microprocessor Interface
Section.
Microprocessor Interface Chip Select. Active low. This pin has the same timing requirements as the
address pins.
Page 6 of 71
ISL5416
Functional Description
The ISL5416 is a four channel digital receiver integrated circuit
offering exceptional dynamic range and flexibility. Each of the
four channels consists of a front-end NCO, digital mixer, CICfilter, two FIR filters, AGC, Interpolation Half Band Filter and
Re-sampling Filter. The parameters for the four channels are
independently programmable.
There are four 17-bit parallel data input busses (Ain(16:0),
Bin(16:0), Cin(16:0) and Din(16:0)). The ISL5416 supports
both fixed and floating point parallel data input modes. The
floating point modes support gain ranging A/D converters or
A/D converter and RF/IF Attenuators or VGAs. Gated or
interpolated data input modes are supported. Each input can
be connected to any or all of the internal signal processing
channels, Channels 0, 1, 2 and 3. The four channels share a
common processing clock (CLKC). Four input clocks are
provided to allow for clock skew between input sources. Each
input has a Range Control circuits to monitor the signal level on
the parallel data busses and to control the gain prior to the A/D
converters. A 16-bit bus (Eout(15:0)) is provided to control the
external VGA/RF Attenuators.
Each front end NCO/digital mixer/CIC filter section includes a
quadrature numerically controlled oscillator (NCO), digital mixer,
barrel shifter and a cascaded-integrator-comb filter (CIC). The
NCO has a 32-bit frequency control word. The SFDR of the
NCO is >110dB. The barrel shifter provides a gain of between 245 and 4 to compensate for the gain in the CIC. The CIC filter
order is programmable from 1 to 5 and the CIC decimation factor
can be programmed from 2 to 512 for 5th order, 2048 for 4th
order, 32768 for 3rd order, or 65536 for 1st or 2nd order filters.
The CIC filter can also be bypassed.
Each channel back end section includes two FIR filters, an
AGC, Interpolation Half Band Filter and Resampler. The first
FIR filter can have up to 32 taps and the second can have up
to 64 taps. The 32-tap filter calculates 4 taps per clock, while
the 64-tap filter calculates 8 taps per clock. The coefficients for
the programmable digital filters are 20 bits wide. Each FIR filter
can be bypassed. The AGC section can provide up to 96dB of
either fixed or automatic gain control. For automatic gain
control, two settling modes and two sets of loop gains are
provided. Separate attack and decay slew rates are provided
for each loop gain. Programmable limits allow the user to
specify a gain range less than 96dB.
A fixed coefficient interpolate-by-2 Half Band Filter and a noninteger resampling filter follow the AGC. Coefficients for the
resampling filter are provided in ROM.
Four 16-bit parallel data outputs (Aout(15:0), Bout(15:0),
Cout(15:0) and Dout(15:0)) are provided. The output of each
channel can be routed to any of the output buses. Outputs from
more than one channel can be multiplexed through a common
output if the channels are synchronized. Dout(15:0)) can
alternately be used as four serial output pairs. A common
output clock (CLKO1) is used for the parallel output buses. A
FN6006 Rev 3.00
Aug 2004
second clock output pin (CLKO2/INTRPT) is provided to
simplify board routing or to allow a complementary output
clocks.
The ISL5416 is programmed through a 16-bit microprocessor
interface. The output data can also be read via the
microprocessor interface. The ISL5416 is specified to operate
to a maximum clock rate of 95 MSPS over the industrial
temperature range (-40oC to 85oC). The I/O power supply
voltage range is 3.3V  0.165V while the core power supply
voltage is 1.8V 0.09V.
Input Select/Format Block
CLOCKING
The channel processing and output timing is clocked with the
rising edge of CLKC. Each input bus can be clocked with the
rising or falling edge of its own clock or with the rising or falling
edge of CLKC. The frequency of all the clocks must be the
same, but providing separate clocks allows the inputs from
multiple A/D converters to have a small amount of skew.
INPUT FORMAT
The inputs can be fixed point or floating point with
mantissa/exponents sizes of 14/3, 15/2, or 16/1. The exponent
inputs are added to the exponent from the internal range
control circuits, so if the range control circuits are used, the
exponent pins are typically grounded and/or disabled via
software in IWA = 0*10h, bit 3. The input format may be twos
complement or offset binary format in either fixed or floating
point modes (IWA = 0*00h).
GATED/INTERPOLATED MODES
For input sample rates at sub-multiples of the clock rate, gated
and interpolated input modes are provided. Each input channel
has an input enable (ENIx, x = A, B, C or D). In the gated
mode, one input sample is processed per clock that the ENIx
signal is asserted (low). Processing is disabled when ENIx is
high. The ENIx signal is pipelined through the part to minimize
delay (latency). In the interpolated mode, the input is zeroed
when the ENIx signal is high, but processing inside the part
continues. This mode inserts zeros between the data samples,
interpolating the input data stream up to the clock rate. The
spacing between ENIx signals must be constant in the
interpolated mode.
MULTIPLEXED INPUT MODE
Each input section can select one channel from a multiplexed
data stream of up to 8 channels. The input enable is delayed
by 0 to 7 clock cycles to enable a selection register. The
register following the selection register is enabled by the nondelayed input enable to realign the processing of the channels.
The one-clock-wide input enable must align with the data for
the first channel. The desired channel is then selected by
programming the delay. A delay of zero selects the first
channel, a delay of 1 selects the second, etc. Each input
section selects only one channel of the multiplexed stream, so
a separate input bus must be used for each channel of the
multiplexed data stream.
Page 7 of 71
ISL5416
CLKC
CLKX
R1
R2
R3
R4
R3
R4
CLKC
CLKX
R1
R2
INTERPOLATE
BUS REVERSE
FLOAT/FIX
SLOT#
OBIN
ENIX
XIN(16:0)
CLK/CLK
R1
R
R
E
G
R2
R3
R4
R
E
G
R
E
G
R
E
G
^
^
^
^
PROCESSING
ENABLE
(16:0)
M
U
(0:16) X
F
M
T
R
M
A
P
D
M
U
X
R
E
G
MANTISSA
EXPONENT
^
TO CHANNELS
AND RANGE
CONTROL
MUX
CLKX/CLKC
MUX
DIN (ONLY)
CLKX
TO SERIAL
FREQUENCY
OFFSET
CLK
CLKC
NOTE: To simplify the board routing, each of the four input data busses can be reversed, MSB for LSB (see IWA = 0*00h, bit 4)
FIGURE 1. INPUT SECTION
SYNCInX Use
SYNCInX main purpose is as a processing start-up signal after
a reset to align the start of processing of multiple channels or
chips. This assures that the carrier phases have a known
relationship and that the output timing aligns for multiplexing
outputs. It can also be used after start-up as a system timing
synchronization signal. Two SYNCInX signals are provided so
that one can be used as a regularly occurring signal (such as
at time slot boundaries) and one as an infrequent signal (such
as at start up or at 1 pps). If more than one air interface
standard is processing in one part, one SYNCInX signal could
be used for the slot timing for each standard.
the same part are time aligned. However, when synchronizing
multiple parts the processor will need knowledge of the
SYNCInX timing so that enabling the SYNCInX in multiple
parts occurs between SYNCInX pulses. Alternatively, SYNCIn1
could be used as a regularly occurring SYNCI signal and
SYNCIn2 could be a gated version. The channel processing
control register might only be updated on SYNCIn2 and the
other SYNCI functions would respond to SYNCIn1.
Register updates from a processor write are synchronized to
the clock, so that the register updates in multiple channels of
FN6006 Rev 3.00
Aug 2004
Page 8 of 71
ISL5416
VGA/RF Attenuator (A/D Range Control)
The range control section monitors the output of the A/D and
adjusts the RF/IF gain to maintain a desired A/D output
range. The gain adjustments are in 6 dB steps. The levels,
adjustment rates, and gain to bit mapping are
programmable.
The range control section uses three programmable
thresholds. Two thresholds, an upper and a lower threshold,
are compared against the average magnitude of the A/D
output. The range control adjusts the gain to keep the
average A/D output between the upper and lower
thresholds. If the average is above the upper threshold, an
internal attenuator control register is increased by a
programmable amount. If the average is below the lower
threshold, the gain attenuator control register is decreased
by a separate programmed amount. The number of samples
averaged for each decision is programmable. The
adjustments to the attenuator control register can be less
than 6 dB to further filter the inputs. Only the three MSBs of
the attenuator control register are used to control the RF/IF
gain, and these are weighted as 6, 12, 24 dB steps.
The third threshold, an immediate threshold, is compared
against the magnitude of each A/D sample. If the magnitude
of any A/D sample exceeds the threshold, the attenuator
control register is immediately increased by the amount
programmed for the immediate threshold. Because there will
be some time delay from a register change until the effect of
the change is seen at the A/D, the immediate threshold is
disabled for a programmable number of clock cycles after it
has been triggered.
To maximize the input sensitivity the range control also
includes a programmable bias. If the average signal is
between the upper and lower threshold, the bias value is
FN6006 Rev 3.00
Aug 2004
added from the attenuator control register. This bias
removes attenuation when it is no longer needed to avoid
missing small signals due to high input noise figure.
Four counters control the amount of time that the input is
averaged and align the adjustments to time slot boundaries.
One counts out the time slot period. If desired, this counter
can be reset by a SYNCInX signal to align its count to the
system timing. A second counter provides a programmable
delay from the start of the first counter's period to the start of
the integration period. This compensates for system delays
or allows the adjustments to be made over a certain portion
of the time slot. The third counter sets the integration period
for averaging the input samples for the upper and lower
threshold decisions. The fourth counter controls the number
of integration periods per time slot. See Figure 2 for a block
diagram. Note that the counters are ignored for the
immediate threshold decisions.
The user can program a separate code for output on the
EOUT bus for each of the eight possible states of the three
MSBs of the attenuator control register. These codes can be
up to 8 bits, but if four gain control sections are used, only
four bits are available for each gain control section. The
mapping of the gain control bits to EOUT bits is done in
GWA = 0001h and the codes are programmed in IWA =
0*17h and 0*18h.
The three MSBs of the attenuator control register can be
routed internally to the channels to be used as the floatingpoint exponents. This adds gain in 6 dB steps to
compensate for the 6 dB steps of RF attenuator. The MSBs
can be added to the input exponent bits if desired. There is a
programmable delay from the attenuator control register to
the channel input to compensate for RF/IF filter group delay
and A/D and ISL5416 pipeline delays.
Page 9 of 71
ISL5416
SYNC
FROM INPUT SECTION
ENABLE COUNTERS
MANTISSA
LD
=0
DOWN
COUNTER
(SLOT
PERIOD)
|X|
BYPASS
HPF
BW SELECT
EN
INPUT
EXP
EN
LD
0
DOWN
COUNTER =0
DELAY
(SYNC TO
START OF
INTEGRATION)
|X|


REG
OFFSET TO BASE
CIC SHIFT VALUE
INTERVAL
EXPONENT
EN
INTEGRATION
TIME
LD
<0
DOWN
COUNTER =0
DUMP
REG
BARREL
SHIFT
2(-1 TO -16)
1-256
CLOCKS
ENABLE
UPDATES
TH3
TH2
TH1
A
B
B
A
A>B
UPPER
A>B
IMMEDIATE
LD
DOWN
COUNTER
A
PROG
DELAY



PRLD(7:0)
B
A<B
LOWER
REG
DECODE
“0”
BIAS
DELTA1
DELTA2
DELTA3
MUX
P ENABLE

MUX
EN
INTEGRATIONS
LD
0
PER SLOT - 1
DOWN
COUNTER
EN
ATTEN
EXP
R
E
G
3
8
16
EOUT
R
E
G
MAP
8
8
8
FROM
OTHER
DETECT.
UPPER GAIN LIMIT
LOWER GAIN LIMIT
LIMIT
DETECTOR
LUT
8
LUT = LOOK UP TABLE
FIGURE 2. RANGE CONTROL BLOCK DIAGRAM
FN6006 Rev 3.00
Aug 2004
Page 10 of 71
ISL5416
NCO/Mixer
After the input select/format section, the samples are multiplied
by quadrature sine wave samples from the carrier NCO. The
NCO has a 32-bit frequency control, providing sub-hertz
resolution at the maximum clock rate. The quadrature
sinusoids have exceptional purity. The purity of the NCO
should not be the determining factor for the receiver dynamic
range performance (A typical spectrum plot is shown in Figure
20). The phase quantization to the sine/cosine generator is 24
bits and the amplitude quantization is 19 bits.
R
DECIMATION E
COUNTER G
R R R
E E E
G G G
ENP
MAX EXP
R R
E E
G G
MUX
EXPA
EXPB
EXPC
EXPD
C
L
I
P
R R R
E E E
G G G
MUX
R R
E E
G G
MUX
ENA
ENB
ENC
END
The carrier NCO center frequency is loaded via the uP bus. The
center frequency control is double buffered -- the input is loaded
into a holding register via the uP interface. The data is then
transferred from the holding register to the active register by a
write to a special address or by a SYNCInX signal, if enabled in
IWA = *000h. To synchronize multiple channels, the carrier NCO
phase accumulator feedback can be zeroed on loading to restart
all of the NCOs at the same phase (see IWA = *005h). The phase
of the NCO can be offset by programming IWA = *003h. The
phase offset is not double buffered.
R R R
E E E
G G G
BASE
SHIFT
VALUE
(from uP)
EXPP
PMANT
(TEST INPUT)
0...-23
R R R
E E E
G G G
REG
0...-23
ENCOF
FIXED INPUT GAIN = 2-45
SHIFT GAIN = 20 TO 247
0...-18
REG
REG
SIN/COS
GEN
R
E
G
0...-23
0...-29
R R R
FIR
FILTER E E E
G G G
(COMB)
MUX
0...-15
INTEGRATE
REG
INTEGRATE
REG
INTEGRATE
REG
INTEGRATE
REG
INTEGRATE
REG
R R
E E
G G
MUX
AMANT
BMANT
CMANT
DMANT
BARREL SHIFTER
0...-23
R
E
G
34b
44b
53b
62b
69b
REG
COF
SERIAL
FREQ
OFFSET
CIC ORDER
FIR COEFFICIENTS
1
COFSYNC
1
2
REG
1
3
REG
REG
4
5
CENTER
FREQ
1
1
1
-2
-3
-4
-5
-1
1
3
6
10
-1
-4
-10
1
5
-1
PHASE
OFFSET
NOTE:
BUS NUMBERING SUCH AS 0...-23 INDICATES BIT WEIGHTS
SUCH AS 20 ... 2-23
FIGURE 3. NCO, MIXER AND CIC BLOCK DIAGRAM
FN6006 Rev 3.00
Aug 2004
Page 11 of 71
ISL5416
TABLE 1. PN GENERATOR BIT WEIGHTING
2^
SIGNAL
0
-1
-2
-3
-4
-5
-6
-7
-8
-9
PN
S
S
S
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
GAIN REG
PN Generator
After the mixers, a PN (pseudonoise) signal can be added to the
data. This feature is provided for test and to digitally reduce the
input sensitivity and adjust the receiver range (sensitivity). The
effect is the same as increasing the noise figure of the receiver,
reducing its sensitivity and overall dynamic range. The one bit
PN data is scaled by a 16 bit programmable scale factor. The
overall range for the PN is 0 to 1/4 full scale. A gain of 0
disables the PN input. The bit weighting for the gain is shown
in table 1.
The minimum, non-zero, PN value is 1/218 of full scale (-108
dBFS) on each axis (-105 dbFS total).
CIC Filter
Next, the signal is filtered by a cascaded integrator/comb (CIC)
filter. A CIC filter is an efficient architecture for decimation
filtering. The power or magnitude squared frequency response
of the CIC filter is given by:
 2N

 sin  Mf 
P(f) =  ------------------------
 sin  f
----- 

 R 
where
M = Number of delays (1 for the ISL5416)
N = Number of stages
and R = Decimation factor.
The passband frequency response for 1st (N=1) though 5th
(N=5) order CIC filters is plotted in Figure 20. The frequency
axis is normalized to fS/R, making fS/R = 1 the CIC output
sample rate. Figure 19B shows the frequency response for a
5th order filter but extends the frequency axis to fS/R = 3 (3
times the CIC output sample rate) to show alias rejection for
the out-of-band signals. Figure 19A provides the amplitude of
the first (strongest) alias as a function of the signal frequency
or bandwidth from DC. For example, with a 5th order CIC and
fS/R = 0.125 (signal frequency is 1/8 the CIC output rate)
Figure 19A shows a first alias level of about -87 dB. Figure 19A
is also listed in table form in Table 84.
The CIC filter order is programmable from 0 to 5. The CIC may
be bypassed by setting the CIC IWA = *001h bit 15.
A barrel shifter precedes the CIC filter to compensate for the
large gain range of the CIC. As the barrel shifter only adjusts in
6 dB steps the total CIC/barrel shifter gain ranges from 0.5 to
1.0.
FN6006 Rev 3.00
Aug 2004
-10 -11 -12 -13 -14 -15 -16 -17 -18 -19 -20 -21 -22 -23
The barrel shifter is also used to convert floating point input
data to fixed point for processing. The exponent bits from the
input and/or range control are added to the shift code
programmed by the user to expand the input range. The shift
code that the user programs must take the expected exponent
range into account i.e. the computed shift control must be
reduced by the maximum exponent value. Also note that since
the exponent shifting reduces the effective size of the
integrators, the maximum decimation factor is reduced (See
Tables 2-4).
The integrator bit widths are 69, 62, 53, 44, and 34 for the 1st
through 5th stages, respectively, while the comb bit widths are
all 24. The integrators are sized for decimation factors of up to
512 with 5 stages, 2048 with 4 stages, 32768 with 3 stages,
and 65536 with 1 or 2 stages. Higher decimations in the CIC
should be avoided as they will cause integrator overflow. In the
ISL5416, the integrators are slightly oversized to reduce the
quantization noise at each stage.
A CIC filter has a gain of RN, where R is the decimation factor
and N is the number of stages. Because the CIC filter gain can
become very large with decimation, an attenuator is provided
ahead of the CIC to prevent overflow. The 24 bits of mixer output
are placed on the low 24 bits of a 69 bit bus (width of the first
CIC integrator) for a gain of 2-45. A 48 bit barrel shifter then
provides a gain of 20 to 247 inclusive before passing the data
onto the CIC. The overall gain in the pre-CIC attenuator can
therefore be programmed to be any one of 48 values from 2-45
to 4, inclusive (see IWA = *005h, bits 25:20). This shift factor is
adjusted to keep the total barrel shifter and CIC filter between
0.5 and 1.0. The equation which should be used to compute the
necessary shift factor is:
BASE SHIFT = MAX(0, 45 - CEIL( LOG2( RN ) ) - MAXEXP)
MAXEXP = sum of the maximum exponent range from a
floating point input and the range control.
CIC barrel shifts of greater than 45 will cause MSB bits to be
lost. Most of the floating point modes on the ISL5416 make use
of the CIC barrel shifter for gain. This limits the maximum
usable decimation. See floating point input mode section for
details.
If the CIC is bypassed, BASE SHIFT = 45 - MAXEXP.
MAXEXP = sum of the maximum exponent range from a
floating point input and the range control.
Page 12 of 71
ISL5416
TABLE 2. MAXIMUM ALLOWED CIC DECIMATION VS. NUMBER OF STAGES AND MAXIMUM EXPONENT
CIC STAGES
MAXIMUM FLOATING POINT OR RANGE CONTROL EXPONENT
0
1
2
3
4
5
6
7
5
512
445
388
337
294
256
222
194
4
2435
2048
1722
1448
1217
1024
861
724
3
32768
26007
20642
16384
13003
10321
8192
6501
2
65536
65536
65536
65536
65536
65536
65536
65536
1
65536
65536
65536
65536
65536
65536
65536
65536
TABLE 3. MAXIMUM CIC DECIMATION VERSUS NUMBER OF STAGES AND MAXIMUM EXPONENT TO MAINTAIN AT LEAST 24 BITS
OF DYNAMIC RANGE AT THE CIC OUTPUT
CIC STAGES
MAXIMUM FLOATING POINT OR RANGE CONTROL EXPONENT
0
1
2
3
4
5
6
7
5
512
445
256
128
64
32
16
8
4
2435
2048
1722
1448
1217
1024
861
724
3
32768
26007
20642
16384
13003
10321
8192
6501
2
65536
65536
65536
65536
65536
65536
65536
65536
1
65536
65536
65536
65536
65536
65536
65536
65536
TABLE 4. MAXIMUM CIC DECIMATION VERSUS NUMBER OF STAGES AND MAXIMUM EXPONENT TO MAINTAIN AT LEAST 20 BITS
OF DYNAMIC RANGE AT THE CIC OUTPUT
CIC STAGES
MAXIMUM FLOATING POINT OR RANGE CONTROL EXPONENT
0
1
2
3
4
5
6
7
5
512
445
388
337
294
256
222
128
4
2435
2048
1722
1448
1217
1024
861
724
3
32768
26007
20642
16384
13003
10321
8192
6501
2
65536
65536
65536
65536
65536
65536
65536
65536
1
65536
65536
65536
65536
65536
65536
65536
65536
FN6006 Rev 3.00
Aug 2004
Page 13 of 71
ISL5416
Back-end Routing
MAG
AGC
LOOP
FILTER
MUX
GAIN
FROM
CIC
CASCADED
CHANNELS
FIR1
1X
2X
4X
8X
4 TAPS/CLK
HBF MODE
UP TO 64 TAPS
GAIN
M
U
X
GAIN
CIC
BYPASS
UP TO 32 TAPS
1X
2X
4X
8X
FIR2
AGC
MULT
MAG
DETECT
FIFO
8 TAPS/CLK
IHBF
I
HOIF
Q
I
Q
EXTERNAL AGC GAIN
FIR Filter Blocks
NOTE:
There are two programmable FIR filters in each channel. The
main function of the first filter, FIR1, is to reduce the CIC output
sample rate and maximize the efficiency of the second filter,
FIR2. FIR2 provides the final filtering for the channel of
interest. FIR1 can compute up to 32 taps and has
programmable 20-bit coefficients, 20-bit data inputs, and 24-bit
outputs. FIR2 can compute up to 64 taps and has
programmable 20-bit coefficients, 20-bit input data, and 24-bit
output data. FIR1 can compute 4 filter taps per clock and FIR2
can compute 8. All of the available taps can be utilized if the
overall decimation through the CIC and FIRs is 8 or more. The
impulse response of each FIR can be symmetric or
asymmetric. The decimation for the each FIR is programmable
from 1 to 8.
When loading halfband coefficients, the coefficients must be
centered around the fixed center coefficient, e.g. if there are 23
taps, three compute clocks are required, there are 11 on either
side of the center and multiplier 1 computes C0, C2, C4,
multiplier 2 C6, C8, C10, etc.
If there are 19 coefficients, multiplier 2 computes C4, C6, C8
and multiplier 1 computes Z, C0, and C2, i.e. an extra zero
valued coefficient must be added at each end of the coefficient
set to center the coefficients at the fixed coefficient.
The filters will have unity gain if the sum of all coefficients is
equal to 1 for coefficient bit weighting 20. . . 2-19
To maximize dynamic range, the output bit width of the CIC
and each FIR is 24 bits. A programmable gain stage is
provided before each FIR to compensate for losses in
preceding stages and round to the 20-bit FIR input bit width.
Gains of 1, 2, 4, or 8 can be programmed. Saturation logic is
provided to prevent overflow.
FIR1 includes a half-band filter mode where a fixed center
coefficient of 0.5 is added and the zero valued half-band
coefficients are skipped in the computation. This allows FIR1 to
compute a 15-tap half-band filter in two clock cycles or a 31-tap
half-band filter in four clock cycles.
FN6006 Rev 3.00
Aug 2004
Page 14 of 71
MUX
MUX
0...-23
x1, 2, 4, 8
LIMIT
DET
RND
R
E
G
R
E
G
R R LIMIT
E E DET
G G RND
R R
E E
G G
R
E
G
R
E
G
0...-23
x1, 2, 4, 8
LIMIT
DET
RND
R
E
G
R
E
G
REG
FILE
1
REG
FILE
0
0...-19
R
E
G
REG
FILE
7
FIXED
0 / 0.5
REG
FILE
3
ADD
REG
FILE
6
R
E
G
4...-30
R
E
G
CONTROL
REG
FILE
2
REG
MUX
REG
FILE
1
REG
FILE
0
0...-19
R
E
G
MUX
MUX
FN6006 Rev 3.00
Aug 2004
0...-19
BYPASS
R
E
G
4...-30
R
E
G
MUX
R R LIMIT
E E DET
G G RND
R R
E E
G G
R
E
G
MUX
ENABLE
R
E
G
ISL5416
FIGURE 4. FIR1 AND FIR2 BLOCK DIAGRAMS
Page 15 of 71
ADD
CONTROL
ISL5416
AGC
The automatic gain control (AGC) section adds gain to
maintain the output signal level at a programmed level. The
AGC moderates signal level variation at the output of the part
and reduces the number of bits that must be carried in any post
processing. In the ISL5416, the AGC follows the channel
filtering. The gains through the NCO, mixer, and FIR filter
sections are fixed gains and do not induce AM distortion before
the large interfering signals can be filtered out. If large
interfering signals are not removed by the filtering prior to the
AGC, the gain adjustments by the AGC can AM modulate the
large signals and cause AM sidebands to fall inside the
frequency band of interest.
A block diagram of the AGC is included in figure 6. The AGC
consists of a forward gain path and a loop filter path. In the
forward gain path, the I/Q samples are scaled by the AGC
forward gain value provided by the loop filter. The forward path
gain is divided between a barrel shifter and a multiplier. The
overall forward path gain range is 0 to 96.33 dB. The barrel
shifter provides 0 to 90 dB of gain in steps of 6 dB. The
multiplier provides linear gain between 1.0 and 2.0. Saturation
is provided if there is overflow. The AGC only adds gain. The
loop filter path computes the gain error, filters it, compares it to
gain limits, and provides it to the forward gain path, to the uP
interface, and to the output section. In the loop filter path the
gain error is computed by first computing the magnitude of the
forward path output. The magnitude is then subtracted from a
programmable threshold or set point. The resulting error value
is then scaled by a programmable loop gain and integrated and
provided to the forward path. Programmable limits on the
forward gain allow the user to restrict the gain to a smaller
range than the 96 dB provided.
The forward gain control word and programmable gain limits
are floating-point numbers consisting of a four-bit exponent
that controls the barrel shifter and a mantissa portion that
controls the multiplier. The barrel shifter gain is 2EXP. The
multiplier gain is 16 bits, but the two MSBs are fixed at “01” and
are not included in the gain control word. The mantissa MSB is
therefore weighted as 0.5 and the mantissa gain is 1.0 +
MANT. The total AGC gain in dB is then:
20*log10( 2EXP * (1.0 + MANT)).
The AGC range is then 0 to 96.33 dB for the EXP range of 0 to
15 and MANT range from 0 to 1. Plots of AGC gain versus the
control word are provided in figures 5A and 5B.
The AGC gain word is available through the uP interface and
as a real time output. The gain word is inversely proportional to
the received signal strength in the channel. Signal strength in
dB can be easily estimated by complementing the gain word
and adding an offset equal to the fixed receive path gain in dB.
count modulo N clocks where N is the length of the time slot.
This counter can be restarted with SYNCInX to align/re-align it
with the slots. A second counter counts out a delay from the
SYNCInX or counter-generated sync. This delays the AGC
timing from the SYNCInX signal to compensate for filter group
delay or other system delays. A third counter counts out an
interval. The interval can be used to divide the slot into fast and
slow update periods (timed mode) or into measurement and
update periods (sampled mode). The counters can also be
disabled and the AGC allowed to free run (continuos mode).
A programmable data delay can be inserted in the forward data
path. The loop filter uses the samples into the delay for
computing the new forward gain. The forward gain is then
applied to the samples coming out of the delay. The gain
applied to the output can be continuously updated or can be
updated under the control of the counters. When updated
continuously, the delay causes the forward gain to be based on
samples before and after the delayed sample. This moderates
large signal variations and minimizes the amount of time that
the forward path may be in saturation or be at a small level.
The sampled mode is used for burst type signals where the
gain adjustment is made during the first part of the burst and
then held for the duration of the burst. The programmable
delay can be set so that the first samples of the burst are
exiting the delay when the gain is updated. In this mode, the
gain may have large instantaneous changes, so proper timing
alignment is very important.
In the timed mode, loop filter continuously updates the forward
gain but uses one set of loop gains during part of the burst and
another set for the rest of the burst. This allows the time slot to
be divided into adapt/hold or fast/slow intervals.
The maximum throughput of the AGC depends on the mode. In
the continuous (counters disabled) and timed modes without
delay, the minimum spacing between samples into the AGC is
2 clocks. When the delay is enabled, this increases to 4. In the
sampled mode, the delay is always enabled and the minimum
spacing is 4. The minimum spacing is 1 when the AGC is
bypassed.
The AGC loop feedback path includes a magnitude
computation, an error detector, error scaling (loop gain), and a
loop filter. The magnitude computation in the loop filter is a
multi-pass operation with one pass computed per clock cycle.
The accuracy of the computation depends on the number of
passes. The minimum number of clocks between samples into
the AGC is 2. There is a gain in the magnitude computation
that must be taken into account when programming the AGC
set point. This gain also depends on the number of passes in
The AGC includes a set of counters to synchronize the AGC to
system timing. The counters can be aligned to the SYNCInX
signals if enabled in IWA *000h. One counter is programmed to
FN6006 Rev 3.00
Aug 2004
Page 16 of 71
ISL5416
the computation. A listing the accuracy and gain is provided
below.
gain or by setting the loop gain to zero and programming the
accumulator directly.
TABLE 5. AGC MAGNITUDE COMPUTATION ACCURACY AND
GAIN
The bit weighting for the AGC loop is provided in Table 86.
PASSES
ERROR +/- (dB)
GAIN
2
0.48
1.581
ISL5416 AGC Forward Gain Response
96
3
0.13
1.630
4
0.03
1.642
84
8
0.0001
1.647
72
60
The AGC loop filter is an accumulator (integrator). The output
of the accumulator is the forward gain word that controls the
barrel shifter and multiplier, closing the loop. There are
programmable limits on the accumulator range to minimize
settling time by restricting the AGC to only that portion of the
96 dB range that is needed. The accumulator can be loaded by
the microprocessor. The gain load is double buffered-the gain
is first loaded into a holding register by the uP. The gain is then
transferred from the holding register to the accumulator by a
write to a special address location or by the SYNCInX if
enabled in IWA *000. The AGC can be set to a fixed gain either
by setting the both upper and lower gain limits to the desired
FN6006 Rev 3.00
Aug 2004
48
36
24
12
0
0
32768
65536
98304
131072
163840
196608
229376 262144
Code
FIGURE 5A. ISL5416 AGC FORWARD GAIN RESPONSE
I
ISL5416 AGC Forward Gain Response
Magnified View
6
5
4
dB
Two adjustment/settling modes are provided in the ISL5416. In
the mean settling mode, the loop adjusts the gain so that the
average magnitude is equal to the programmed set point. In
this mode, the error is scaled by the loop gain and integrated to
compute the forward gain. The loop settles to the final value
asymptotically because the size of the adjustment decreases
as the error decreases. The initial settling from large errors is
fast, but the final pull in is slower. After the loop has settled, the
small adjustment size causes minimal AM distortion of the
signal. The other settling mode is the median mode. In this
mode, the sign of the error is used increase or decrease the
gain by a fixed amount. The amount of the adjustment is
programmed by the loop gain. The loop settles to the point
where there are an equal number of samples above and below
the set point. The loop settling is roughly linear in dB, but after
the loop has settled, the step size remains the same, so the
amount of AM distortion may be objectionable. The ISL5416
provides two programmable loop gains, each with a separate
attack and decay settling. The micro-processor can control the
loop gain, or the AGC counters can select the loop gain, so a
large loop gain can be used for initial settling and a smaller one
for tracking. The counters can also select the settling mode, so
the median mode can be used at the beginning of each time
slot and the mean mode used after the initial settling.
dB
With maximum gain and with full scale I and Q inputs equal to
~+/-1.0, the maximum output from the computation is 1.414 *
1.647 = 2.329. The error detector subtracts the magnitude from
the programmable AGC Threshold value. The AGC Threshold
value is set in IWA register *009h and should be programmed
to K times the desired magnitude of the I/Q where K is the gain
of the magnitude computation.
3
2
1
0
0
2048
4096
6144
8192
10240
12288
14336
16384
Code
FIGURE 5B. ISL5416 AGC FORWARD GAIN RESPONSE
MAGNIFIED VIEW (ACTUAL AND IDEAL LINEAR
IN dB)
Page 17 of 71
R
E
G
DELAY
MEMORY
0 - 63
SAMPLES
BARREL
SHIFT
R
E
G
1
0
MUX
S
A
T
OVERFLOW
DETECT
BARREL
SHIFT
|X|
CLOCKS
Z-4
-A
+A

LOOP GAIN
SELECT
SET POINT
Z-5
CLOCKS
DELAY = MAX(1 SAMPLE, 17 CLOCKS)
CLOCKS
Z-6
S
A
T
OVERFLOW
DETECT
0
1
2
SIGN
SIGN
MEAN/MED 1
MEAN/MED 2
MUX
FN6006 Rev 3.00
Aug 2004
ATTACK 1
ATTACK 2
MUX
MUX
DECAY 1
DECAY 2
BARREL
SHIFT

P DATA
R
E
G
LIMIT
DETECTOR
UPPER / LOWER
LIMITS
MUX
SAMPLED
MODE
UPDATE
FORWARD
GAIN
ISL5416
FIGURE 6. AGC BLOCK DIAGRAM
Page 18 of 71
ISL5416
Interpolation Half Band Filter / Re-sampling Filter
A rate change section follows the AGC. This section is used to
resample the signal from FIR2 to increase the sample rate for
finer time resolution and/or to resample the data to another
sample spacing. This section consists of an interpolation halfband filter, an interpolating resampling filter, a decimation
counter/sampler, a FIFO, a set of NCOs, and a “leap” counter.
This processing stage allows the filtering in FIR2 to be done at
the lowest sample rate that meets the Nyquist criteria and the
data then resampled to the desired final sample rate. The
output/input sample rate ratio can be almost any value from
0.125 to >4096. A block diagram is provided below in Figure 8.
The re-sampling filter (HOIF) can accept inputs at any rate up
to its maximum output rate of one half the clock rate. Preceding
the resampler is an interpolation halfband filter. This filter can
be used to provide a fixed interpolation by 2 when the
resampler is bypassed or, when used with the resampler, to
increase the image-free dynamic range of the output. The
IHBF can output at up to the clock rate if the resampling filter is
bypassed and up to one half the clock rate if the resampling
filter is enabled. Frequency response plots are provided below
for the half-band and resampling filters. An example frequency
response for a FIR2 response together with the half-band and
resampling filters is also provided.
The resampling process produces images of the signal at
multiples of the input sample rate. Large interfering signals
must be removed from the spectrum with the CIC, FIR1, and
FIR2 filters or the images created from them in the resampling
process may cause problems. The level of the images created
by resampling process has a fixed dBc level for a given set of
filters and sampling ratio. As the signal level in the channel
increases and decrease, the images levels will increase and
decrease by the same amount. As the ratio of the FIR2 output
sample rate to the band edge increases, the level, in dBc, of
the images decreases.
0
-20
-40
-60
-80
-100
0
5
10
15
6
x 10
FIGURE 7A. INTERPOLATION HALF BAND RESPONSE
10
0
-10
-20
-30
-40
-50
-60
-70
-80
0
0.5
1
1.5
2
2. 5
3
7
FIGURE 7B. IHBF (INTERPOLATE BY 2) AND RESAMPLER (INTERPOLATE BY 2)
x 10
10
0
-10
-20
-30
-40
-50
-60
-70
-80
0
5
10
15
6
x 10
FIGURE 7C. INDIVIDUAL AND COMPOSITE RESPONSES (FIR2
OUTPUT AT 7.68 MHz WITH IHBF, INTERPOLATE BY 2)
FN6006 Rev 3.00
Aug 2004
Page 19 of 71
ISL5416
Two NCOs and two counters set the sample rates through the
rate change section. NCO1 sets the output sample rate of the
resampling filter. NCO1 is 48 bits and is updated at the clock
rate, so its output frequency is:
10
0
-10
Fout1 = Fclk * N1 / 248,
-20
where N1 is the 48-bit programming word. The carry output of
the phase accumulator is used as the output clock, so there
can be one clock period of jitter. NCO2 is programmed for the
input sample rate to the resampler (equals the half-band filter
output rate). NCO2 is updated at the NCO1 output rate. NCO2
controls the phase of the resampling filter. This NCO also has
a 48-bit phase accumulator. The equation for programming the
output frequency of NCO2 is:
-30
-40
-50
-60
-70
-80
0
0. 5
1
1. 5
2
2. 5
3
7
x 10
FIGURE 7D. INDIVIDUAL AND COMPOSITE
RESPONSES (FIR2 OUTPUT AT 7.68 MHz WITH IHBF,
INTERPOLATE BY 2 AND RE-SAMPLER, INTERPOLATE BY 2
Fout2 = Fout1 * N2 / 248 = Fclk * (N1 / 248) * (N2 / 248)
when the resampling filter is enabled and
Fout2 = Fclk * N2 / 248
when the resampling filter is bypassed. NCO2 can have one
output sample period (Fout1 period) of jitter (one clock period
when the HOIF is bypassed).
10
0
-10
A static phase offset can be programmed for NCO2. The range
of the phase offset is 0 to 2 NCO2 output sample periods (0 - 2
resampling filter input sample periods). The programming
resolution is 1/256 of a resampling filter input sample period.
This programmable offset allows the user vary the group delay
of one channel relative to another in very fine increments to
compensate for differences in system delays.
-20
-30
-40
-50
-60
If the resampler is not needed for rate change, it can be used
for phase shifting by setting bit 22 in IWA *001h.
-70
-80
0
5
10
While the 48-bit phase accumulators provide very good
frequency programming resolution, at some input/output
sample rate ratios, there will be a slow phase drift due to the
finite word length. To correct for this, a “leap” counter is
provided to reset the phase of the NCOs after a programmed
interval to remove any accumulated error. The leap counter is
32 bits. If properly programmed, this phase correction will not
be seen in the output of the part.
15
6
x 10
FIGURE 7E. FIR2 AND IHBF COMPOSITE RESPONSE
10
0
-10
-20
-30
-40
-50
-60
-70
-80
0
0.5
1
1.5
2
2.5
3
7
x 10
FIGURE 7F. FIR2, IHBF AND RESAMPLER COMPOSITE
RESPONSE
FN6006 Rev 3.00
Aug 2004
The input rate to the IHBF/RS section must match the output
sample rate of FIR2, i.e. the output rate of NCO2 must equal
the input sample rate of the part divided by the decimation
factors in the CIC, FIR1, and FIR2. The leap counter can
guarantees this over the long term, but due to the jitter of the
phase accumulator outputs, a FIFO is provided to guarantee
that there are no dropped samples. The FIFO is filled at the
output sample rate of the AGC and is emptied by Fout2 (or
Fout2/2 if the IHBF is enabled). After reset, the FIFO is filled to
a depth of two before the NCOs are enabled. This minimum fill
depth guarantees that there are enough samples in the FIFO
that the FIFO never empties or overflows due to NCO jitter if
the NCOs and leap counter are properly programmed. FIFO
reads are enabled after an additional 0 to 3 input samples as
programmed by the user. This additional depth provides for
Page 20 of 71
ISL5416
additional programmable group delay. The additional FIFO
depth can only be programmed at reset. Because the NCOs
are enabled after a depth of 2 is reached, the data into the
IHBF/Resampler is zeroed until the programmed fill depth is
reached. If both the half-band and resampling filters are
enabled, the programmable FIFO depth, together with the
NCO2 phase offset, provides from 0 to 4 FIR2 output sample
periods of programmable group delay in 1/512 increments.
Because the IHBF and RS combination can only interpolate,
for resampling ratios <1, the signal must first be interpolated to
a multiple of the desired sample rate and then decimated to the
final rate. A decimation counter is provided after the
resampling filter to down sample to the desired rate.
The NCO1 and NCO2 frequencies are programmed in IWA =
*011h - *014h. These registers are double buffered. The uP
writes to a holding register. Data is then transferred to the
active registers by a write to IWA = *017h or by a SYNCInX if
enabled in IWA = *000h.
The gain data from the AGC is not interpolated. The output of
the AGC is sampled with each I/Q sample to the output
section.
PHASE OFFSET
0 TO 511/256 SAMPLES
LEAP
COUNTER
R
E
G

REG
Fihbf_out
FIFO
DEPTH =
2 + (0 to 3)
SAMPLES

EN
R R R R R
IHBF E E E E E
G G G G G
REG
N x Fout
Fclk
CO
NCO1
NCO2
RD
WR
0...-15
DIVIDE
BY
1 OR 2
DIVIDE
BY N
MUX
ROUND
Fihbf_in
R
E
G
FRACTIONAL
R RESAMPLING R R R R
E INTERPOLATION E E E E
G G G G
G
FILTER
Fout
MUX
FILL DEPTH BEFORE
ENABLING READS
0, 1, 2, or 3
R
E
G
R
E
G
FIGURE 8. IHBF AND RESAMPLER BLOCK DIAGRAM
FN6006 Rev 3.00
Aug 2004
Page 21 of 71
ISL5416
Data Output Formatter Section
Four 16-bit output data busses are provided on the ISL5416.
All of the busses share a common output clock, CLKO1, which
is derived from CLKC. CLKO2 signal is provided for easier
board routing or for the differential outputs. Each bus has an
output SYNC which is typically used as a frame sync. Each bus
can be divided into two 8-bit busses if desired. When a new
data sample is available from a channel, it starts a time slot
counter that sequences through up to 8 output time slots. The
data type for each time slot is programmable as well as the
FSYNCx assertion. The data from more than one channel can
be multiplexed through the same output bus if channels are
synchronized. The data from channels 0 and 1 and from
channels 2 and 3 can be multiplexed directly. Multiplexing
channels 0 and 1 with 2 and 3 is done by ORing multiplexer
outputs together. See figures 10 and 11. This means that
related channels (such as diversity channels) should be
grouped into channels 0 and 1, or into channels 2 and 3 for
ease of data routing.
The I/Q data from each channel is rounded to 4, 6, 8, 12, 16,
20 or 24 bits at the output of the channel. The AGC gain can be
rounded to 8, 12, or 16 bits. A 24-bit output is provided to the
output section for I and Q data and a 16-bit output is provided
for the AGC data. The data is MSB justified in the output bus
and the LSBs below the programmed number are zeroed.
24 bits of I/Q data is available from the AGC if the IHBF/HOIF
is bypassed. I/Q are 16 bits if the IHBF/HOIF section is
enabled.
Serial outputs are available. See GWA = 0000h, IWA =
0*06h, 0*07h, and 0*08h.
I0
(23:16)
(15:8)
(15:8)
(7:0)
01AC UPPER 16 x 8-BIT MUX
(7:0)
Q0
(23:16)
(15:8)
(7:0)
AGC0
(15:8)
(7:0)
I1
(23:16)
(15:8)
(7:0)
Q1
(23:16)
(15:8)
(7:0)
AGC1
(23:16)
(15:8)
Q0
(23:16)
(15:8)
(7:0)
AGC0
(15:8)
(7:0)
(15:8)
I1
(23:16)
(15:8)
(7:0)
Q1
(23:16)
(15:8)
(7:0)
AGC1
(15:8)
01AC LOWER 16 x 8-BIT MUX
I0
The data type, SYNC assertion, and bus routing are
programmed in registers 0*01h through 0*04h. Two of the eight
time slots are programmed in each location.
(7:0)
(7:0)
(7:0)
01 AC UPPER
Channels
Output Byte
Outputs
FIGURE 9. MULTIPLEXING CHANNELS
FN6006 Rev 3.00
Aug 2004
Page 22 of 71
MUX #1
CHAN 1 DATA
64
64
8
OE_01A
01AC
CHAN 0 DATA
HIGH
ISL5416
AOUT(15:8)
OE_23A
LOW
8
OE_01A
AOUT(7:0)
64
MUX #3
CHAN 3 DATA
64
8
OE_23C
COUT(15:8)
23AC
CHAN 2 DATA
HIGH
OE_23A
OE_01C
LOW
8
OE_23C
COUT(7:0)
MUX #2
CHAN 1 DATA
64
8
OE_01B
BOUT(15:8)
01BD
CHAN 0 DATA
64
HIGH
OE_01C
OE_23B
LOW
8
OE_01B
BOUT(7:0)
CHAN 3 DATA
64
LOW
MUX #4
64
8
OE_23D
23BD
CHAN 2 DATA
HIGH
OE_23B
DOUT(15:8)
OE_01D
8
OE_23D
DOUT(7:0)
OE_01D
FIGURE 10. OUTPUT ROUTING
FN6006 Rev 3.00
Aug 2004
Page 23 of 71
ISL5416
Serial Data Output
The serial data output control register contains sync position
and polarity (SSYNCA, B, C or D), channel multiplexing, and
scaling controls for the SD1x and SD2x (x = A, B, C or D) serial
outputs (see IWA registers 0*06 - 0*08h).
Serial Data Output Time Slot
Content/Format Registers
These two registers are used to program the content and
format of the serial data output sequence time slots (see IWA
registers 0*07h and 0*08h). There are four data time slots that
make up a serial data output stream. The number of data bits
and data format of each slot is programmable as well as
whether there will be a sync generated with the time slot (the
syncs are only associated with the SD1 serial outputs). Any of
three types of data or zeros can be chosen for each time slot.
Seven bits are used to specify the content and format of each
slot.
Channel Routing Mask
The multiplexing mask bits for each channel (see
Microprocessor Interface Section, IWA register 0*06h bits
19:16 for SD1x or bits 15:12 for SD2x) can be used to enable
that channel’s output to any of the four serial outputs. These
bits control AND gates that mask off the channels, so a zero
disables the channel’s connection to that output.
To configure more than one channel's output onto a serial data
output, the SD1 serial outputs and syncs from each channel
(0,1, 2 and 3) are brought to each of the SD1 serial output
sections and the SD2 serial outputs are brought to each of the
SD2 serial output sections (the syncs are only associated with
the SD1 serial outputs). There, the four outputs are AND-ed
with the multiplexing mask programmed in the serial data
output control registers of channels 0 thru 3 and OR-ed
together. By gating off the channels that are not wanted and
delaying the data from each desired channel appropriately, the
channels can be multiplexed into a common serial output
stream. It should be noted that in order to multiplex multiple
channels onto a single serial data stream the channels to be
multiplexed must be synchronous.
Microprocessor Interface
The ISL5416 Microprocessor (P) interface consists of a 16-bit
bidirectional data bus, P(15:0), three address pins, ADD(2:0), a
write strobe (WR), a read strobe (RD) and a chip enable (CE).
Indirect addressing is used for control and configuration of the
ISL5416.
address 2. When the address is written, a synchronization
circuit generates an internal write strobe, synchronized to the
clock, to clock the data into the target register. The
synchronization process requires 4 clock cycles, so data
should not be written to direct addresses 0 or 1 for four clock
cycles after a write to address 2. To read data from internal
locations, the internal address is first written to direct address
3. The data can then be read from direct addresses 0 (15:0)
and 1 (31:16). The indirect address register is shared between
direct addresses 2 and 3, with only writes to address 2
generating write strobes. Because of this, the address does
not have to be re-written to verify a write unless broadcasting
data to more than one channel.
Direct address 2 is used for status when read. The status bits
are defined in Table of Microprocessor Direct Read/Write
Addresses. Direct addresses 4 through 7 are used for fast read
access.
Addresses 4 through 7 (one address per channel) are used for
sequenced read (FIFO-like) addresses. The user can program
the order that the data would be read from the part. The user
can select I, Q, AGC Gain (real time or sampled), and two
types of data from the range control circuit. When a new output
is available, the data type pointer is reset to the first data type.
After each read, the pointer is incremented to the next data
type. To signal a new output on the channel, a signal can be
routed to the CLKO2/INTRPT pin. A channel is enabled to
generate interrupt in address IWA = 0*0Ah, bit 31. If separate
interrupt signals are required for each channel, the FSYNCX
pins can be used.
The indirect address space is divided into top level or global
locations for parameters that are shared between channels or
I/Os, I/O control locations, and channel control parameters.
The global locations are between addresses 0000h and
00FFh. The I/O control locations are between 0100h and
0FFFh. Bits 11, 10, 9, and 8 select I/O busses D, C, B, and A,
respectively. What this means is that by setting a single
address bit of 11:8, the control register is written for that I/O
control section. By setting more than one bit, the same data is
written to the corresponding registers of more than one I/O
control section. Reads must select only one I/O control section.
Channel control registers are located between addresses
1000h and FFFFh. Bits 15, 14, 13, and 12 select channels 3, 2,
1, and 0, respectively. The user can write to individual
channels or to multiple channels at once by setting the
appropriate channel select bit, 15:12. Read addresses must
specify a single channel.
The processor interface to the ISL5416 is a mixture of direct
and indirect addressing. To minimize the amount of processor
address space and bus routing, there are only eight 16-bit
direct address locations. Two of these are used to access an
internal 32-bit bus. To write data to internal indirect locations,
the data is first written to direct addresses 0 (bits 15:0) and 1
(bits 31:16). The internal address is then written to direct
FN6006 Rev 3.00
Aug 2004
Page 24 of 71
ISL5416
To Write to the Internal Registers:
1. Load the indirect write holding registers at direct address
ADD(2:0) = 0 and 1 with the data for the internal register (32
bits).
2. Write the Indirect Write Address of the internal register
being addressed to direct address ADD(2:0) = 2 (Note: A
write strobe to transfer the contents of the Indirect Write
Holding Register into the Target Register specified by the
Indirect Address will be generated internally).
3. Wait 4 clock cycles before performing the next write to the
indirect write holding registers.
To Read Internal Registers:
1. Write the Indirect Read Address of the internal register
being read to direct address ADD(2:0) = 3.
2. Perform a read of the Indirect Read Holding Registers at
direct address ADD(2:0) = 0 and 1.
NOTE: After an indirect write to a single channel, the data can
be read at direct addresses 0 and 1 after 4 clock periods.
JTAG
JTAG: The IEEE 1149.1 Joint Test Action Group boundary
scan standard operational codes shown in Table 2 are
supported. A separate application note is available with
implementation details
JTAG Op Codes Supported
TABLE 6.
INSTRUCTION
OP CODE
EXTEST
0000
IDCODE
0001
SAMPLE/PRELOAD
0010
INTEST
0011
BYPASS
1111
TABLE 7. STATUS BITS READ DIRECT ADDRESS 2 FOR (15:0)
15:8
REVISION CODE.
0x00h = prototype silicon.
0x01h = production silicon.
7:6
CHANNEL 3 STATUS. Bit 7 is always zero, bit 6 indicates data path saturation.
5:4
CHANNEL 2 STATUS. Bit 5 is always zero, bit 4 indicates data path saturation.
3:2
CHANNEL 1 STATUS. Bit 3 is always zero, bit 2 indicates data path saturation.
1:0
CHANNEL 0 STATUS. Bit 1 is always zero, bit 0 indicates data path saturation.
Bits 0, 2, 4, 6 are the OR-ing together of the individual data
path. Saturation bits listed in *01Fh (Table 14). These bits are
latched when set. Awrite to *01F clears the bit(s).
FN6006 Rev 3.00
Aug 2004
Page 25 of 71
ISL5416
TABLE OF MICROPROCESSOR DIRECT READ/WRITE ADDRESSES
ADD(2:0)
PINS
REGISTER DESCRIPTION
0
WR
Indirect Write Data Bus (15:0), “Master (15:0)”.
1
WR
Indirect Write Data Bus (31:16), “Master (31:16)”.
2
WR
Indirect Write Address Register for Internal Target Register (Generates a write strobe to transfer contents of the
Write Holding Register into the Target Register specified by the Indirect Address, see also Tables of Indirect
Address Registers).
3
WR
Indirect Read Address Register (Used to select the Read source of data - uses the same register as Direct
Address 2 but does not generate a write strobe).
4
WR
RESERVED
5
WR
RESERVED
6
WR
RESERVED
7
WR
RESERVED
0
RD
Indirect Read, Bits 15:0.
1
RD
Indirect Read, Bits 31:16.
2
RD
Status (15:0).
3
RD
RESERVED
4
RD
Channel 0 Sequenced Read Address.
5
RD
Channel 1 Sequenced Read Address.
6
RD
Channel 2 Sequenced Read Address.
7
RD
Channel 3 Sequenced Read Address.
Power-up Sequencing
The ISL5416 core and I/O blocks are isolated by structures
which may become forward biased if the supply voltages are
not at specified levels. During the power-up and power-down
operations, differences in the starting point and ramp rates of
the two supplies may cause current to flow in the isolation
structures which, when prolonged and excessive, can reduce
the usable life of the device.
In general, the most preferred case would be to power-up the
core and I/O structures simultaneously. However, it is also safe
to power-up the core prior to the I/O block if simultaneous
application of the supplies is not possible. In this case, the I/O
voltage should be applied in 10ms to 100ms nominally to
preserve supply component reliability. Bringing the core and
I/O supplies to their respective regulation levels in a maximum
time frame of a 100ms, moderates the stresses placed on
both, the power supply and the ISL5416.
FN6006 Rev 3.00
Aug 2004
Page 26 of 71
ISL5416
Table of Indirect Read and Write Address Registers
NOTE: These Indirect Read Addresses are repeated for each channel. In the addresses below, the * fields are the channel
and I/O select nibble. These bits of the Indirect Address select the target I/O or channel register for the data being read.
TABLE 8. TOP - GLOBAL WRITES
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
0
DESCRIPTION
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0 TOP LEVEL, COMMON OUTPUT CONTROLS AND CHANNEL-TO-CHANNEL
DATA ROUTING
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1 RANGE CONTROL TO EOUT MAPPING
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0 uP TEST INPUT DATA, TEST OUTPUT ENABLES
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1 uP TEST DATA STROBE
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0 SYNCO STROBE GENERATION
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
1 SYNCO WITH INTERNAL SYNCIn1 FEEDBACK
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
0 SOFTWARE HARD RESET
0007 - 00FF RESERVED
TABLE 9. TOP - GLOBAL READS
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
0
DESCRIPTION
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0 CONTROL REGISTER 0000h
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1 CONTROL REGISTER 0001h
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0 CONTROL REGISTER 0002h
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1 N/A (STROBE)
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0 N/A (STROBE)
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
1 N/A (STROBE)
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
0 N/A (STROBE)
0007 - 00FF RESERVED
TABLE 10. XIN, XOUT, XRNG WRITES (X = A, B, C, D AS SPECIFIED BY * NIBBLE BITS)
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
0
0
0
0
0
*
*
*
*
0
0
0
0
0
0
0
0 INPUT FORMAT
0
0
0
0
*
*
*
*
0
0
0
0
0
0
0
1 PARALLEL OUTPUT ROUTING 1 - TIME SLOTS 0, 1
0
0
0
0
*
*
*
*
0
0
0
0
0
0
1
0 PARALLEL OUTPUT ROUTING 2 - TIME SLOTS 2, 3
0
0
0
0
*
*
*
*
0
0
0
0
0
0
1
1 PARALLEL OUTPUT ROUTING 3 - TIME SLOTS 4, 5
0
0
0
0
*
*
*
*
0
0
0
0
0
1
0
0 PARALLEL OUTPUT ROUTING 4 - TIME SLOTS 6, 7
0
0
0
0
*
*
*
*
0
0
0
0
0
1
0
1 RANGE CONTROL SYNCInX CONTROLS
0
0
0
0
*
*
*
*
0
0
0
0
0
1
1
0 SERIAL OUTPUT CONTROL
0
0
0
0
*
*
*
*
0
0
0
0
0
1
1
1 SERIAL OUTPUT SD1X TIME SLOTS
0
0
0
0
*
*
*
*
0
0
0
0
1
0
0
0 SERIAL OUTPUT SD2X TIME SLOTS
0
0
0
0
*
*
*
*
0
0
0
0
1
0
0
1 RANGE CONTROL DC BLOCKING FILTER
0
0
0
0
*
*
*
*
0
0
0
0
1
0
1
0 SEQUENCED READ ORDER
*
*
*
*
*
*
*
*
0
0
0
0
FN6006 Rev 3.00
Aug 2004
DESCRIPTION
0*0B - 0*0F RESERVED
0
0
0
1
0
0
0
0 RANGE CONTROL CONTROL
Page 27 of 71
ISL5416
TABLE 10. XIN, XOUT, XRNG WRITES (X = A, B, C, D AS SPECIFIED BY * NIBBLE BITS)
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
0
DESCRIPTION
0
0
0
0
0
*
0
*
0
0
0
1
0
0
0
1 RANGE CONTROL SLOT PERIOD, DELAYx
0
0
0
0
0
*
0
*
0
0
0
1
0
0
1
0 RANGE CONTROL INTEGRATION TIME, NUMBER OF INTEGRATIONSx
0
0
0
0
0
*
0
*
0
0
0
1
0
0
1
1 RANGE CONTROL LOWER THRESHOLD, DELTAx
0
0
0
0
0
*
0
*
0
0
0
1
0
1
0
0 RANGE CONTROL UPPER THRESHOLD, DELTAx
0
0
0
0
0
*
0
*
0
0
0
1
0
1
0
1 RANGE CONTROL IMMEDIATE THRESHOLD, DELTAx
0
0
0
0
0
*
0
*
0
0
0
1
0
1
1
0 RANGE CONTROL BIASx
0
0
0
0
*
*
*
*
0
0
0
1
0
1
1
1 RANGE CONTROL ATTENUATION CONTROL CODES 0 - 3
0
0
0
0
*
*
*
*
0
0
0
1
1
0
0
0 RANGE CONTROL ATTENUATION CONTROL CODES 4 - 7
0
0
0
0
*
*
*
*
0
0
0
1
1
0
0
1 RANGE CONTROL uP ATTENUATION ACCUMULATOR LOAD
0
0
0
0
*
*
*
*
0
0
0
1
1
0
1
0 RANGE CONTROL ACCUMULATOR LOAD STROBE
0
0
0
0
*
*
*
*
0
0
0
1
1
0
1
1 RANGE CONTROL ACCUMULATOR READ STROBE
0
0
0
0
*
*
*
*
0
0
0
1
1
1
0
0 RANGE CONTROL INTEGRATOR READ SAMPLE STROBE
0
0
0
0
*
*
*
*
0
0
0
1
1
1
0
1 RANGE CONTROL DC OFFSET READ SAMPLE STROBE
0*1E - 0*FF RESERVED
x = These control registers are shared between inputs A and B
and between inputs C and D.
TABLE 11. XIN, XOUT, XRNG READS (X = A, B, C, D AS SPECIFIED BY * NIBBLE BITS)
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
0
DESCRIPTION
0
0
0
0
*
*
*
*
0
0
0
0
0
0
0
0 CONTROL REGISTER 0*00
0
0
0
0
*
*
*
*
0
0
0
0
0
0
0
1 CONTROL REGISTER 0*01
0
0
0
0
*
*
*
*
0
0
0
0
0
0
1
0 CONTROL REGISTER 0*02
0
0
0
0
*
*
*
*
0
0
0
0
0
0
1
1 CONTROL REGISTER 0*03
0
0
0
0
*
*
*
*
0
0
0
0
0
1
0
0 CONTROL REGISTER 0*04
0
0
0
0
*
*
*
*
0
0
0
0
0
1
0
1 CONTROL REGISTER 0*05
0
0
0
0
*
*
*
*
0
0
0
0
0
1
1
0 CONTROL REGISTER 0*06
0
0
0
0
*
*
*
*
0
0
0
0
0
1
1
1 CONTROL REGISTER 0*07
0
0
0
0
*
*
*
*
0
0
0
0
1
0
0
0 CONTROL REGISTER 0*08
0
0
0
0
*
*
*
*
0
0
0
0
1
0
0
1 CONTROL REGISTER 0*09
0
0
0
0
*
*
*
*
0
0
0
0
1
0
1
0 CONTROL REGISTER 0*0A
0*0B - 0*0F RESERVED
0
0
0
0
*
*
*
*
0
0
0
1
0
0
0
0 CONTROL REGISTER 0*10
0
0
0
0
0
*
0
*
0
0
0
1
0
0
0
1 CONTROL REGISTER 0*11, * = 1, 4 ONLY
0
0
0
0
0
*
0
*
0
0
0
1
0
0
1
0 CONTROL REGISTER 0*12, * = 1, 4 ONLY
0
0
0
0
0
*
0
*
0
0
0
1
0
0
1
1 CONTROL REGISTER 0*13, * = 1, 4 ONLY
0
0
0
0
0
*
0
*
0
0
0
1
0
1
0
0 CONTROL REGISTER 0*14, * = 1, 4 ONLY
0
0
0
0
0
*
0
*
0
0
0
1
0
1
0
1 CONTROL REGISTER 0*15, * = 1, 4 ONLY
0
0
0
0
0
*
0
*
0
0
0
1
0
1
1
0 CONTROL REGISTER 0*16, * = 1, 4 ONLY
0
0
0
0
*
*
*
*
0
0
0
1
0
1
1
1 CONTROL REGISTER 0*17
0
0
0
0
*
*
*
*
0
0
0
1
1
0
0
0 CONTROL REGISTER 0*18
0
0
0
0
*
*
*
*
0
0
0
1
1
0
0
1 RANGE CONTROL LOAD VALUE READ (HOLDING REGISTER)
FN6006 Rev 3.00
Aug 2004
Page 28 of 71
ISL5416
TABLE 11. XIN, XOUT, XRNG READS (X = A, B, C, D AS SPECIFIED BY * NIBBLE BITS) (Continued)
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
0
DESCRIPTION
0
0
0
0
*
*
*
*
0
0
0
1
1
0
1
0 N/A (STROBE)
0
0
0
0
*
*
*
*
0
0
0
1
1
0
1
1 RANGE CONTROL ACCUMULATOR READ AFTER A WRITE TO THIS
LOCATION TO STABILIZE
0
0
0
0
*
*
*
*
0
0
0
1
1
1
0
0 RANGE SELECT INTEGRATOR READ AFTER A WRITE TO THIS LOCATION
TO STABILIZE
0
0
0
0
*
*
*
*
0
0
0
1
1
1
0
1 RANGE SELECT DC OFFSET READ AFTER A WRITE TO THIS LOCATION TO
STABILIZE
0*1E - 0*FF RESERVED
TABLE 12. CHANNEL CONTROL REGISTERS (WRITES)
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
0
DESCRIPTION
*
*
*
*
0
0
0
0
0
0
0
0
0
0
0
0 CHANNEL SYNC CONTROL
*
*
*
*
0
0
0
0
0
0
0
0
0
0
0
1 CHANNEL DATA PATH, CONTROL 
*
*
*
*
0
0
0
0
0
0
0
0
0
0
1
0 CARRIER CENTER FREQUENCY HOLDING REGISTER 
*
*
*
*
0
0
0
0
0
0
0
0
0
0
1
1 CARRIER PHASE OFFSET
*
*
*
*
0
0
0
0
0
0
0
0
0
1
0
0 CARRIER FREQUENCY LOAD STROBE
*
*
*
*
0
0
0
0
0
0
0
0
0
1
0
1 NCO/CIC CONTROL
*
*
*
*
0
0
0
0
0
0
0
0
0
1
1
0 PN NOISE LEVEL
*
*
*
*
0
0
0
0
0
0
0
0
0
1
1
1 FIR1, FIR2 CINTROL, RE-SAMPLING FILTER OUTPUT DECIMATION
*
*
*
*
0
0
0
0
0
0
0
0
1
0
0
0 AGC CONTROL
*
*
*
*
0
0
0
0
0
0
0
0
1
0
0
1 AGC SET POINT
*
*
*
*
0
0
0
0
0
0
0
0
1
0
1
0 AGC UPPER AND LOWER GAIN LIMITS
*
*
*
*
0
0
0
0
0
0
0
0
1
0
1
1 AGC LOOP GAINS
*
*
*
*
0
0
0
0
0
0
0
0
1
1
0
0 AGC COUNTER PRELOADS 1
*
*
*
*
0
0
0
0
0
0
0
0
1
1
0
1 AGC COUNTER PRELOADS 2
*
*
*
*
0
0
0
0
0
0
0
0
1
1
1
0 AGC uP GAIN LOADING REGISTER 
*
*
*
*
0
0
0
0
0
0
0
0
1
1
1
1 AGC uP GAIN LOADING STROBE
*
*
*
*
0
0
0
0
0
0
0
1
0
0
0
0 AGC STROBE TO SAMPLE GAIN FOR READ
*
*
*
*
0
0
0
0
0
0
0
1
0
0
0
1 RE-SAMPLING FILTER NCO1 - OUTPUT RATE 47:16 
*
*
*
*
0
0
0
0
0
0
0
1
0
0
1
0 RE-SAMPLING FILTER NCO1 - OUTPUT RATE 15:0 
*
*
*
*
0
0
0
0
0
0
0
1
0
0
1
1 RE-SAMPLING FILTER NCO2 - INPUT RATE 47:16 
*
*
*
*
0
0
0
0
0
0
0
1
0
1
0
0 RE-SAMPLING FILTER NCO2 - INPUT RATE 15:0 
*
*
*
*
0
0
0
0
0
0
0
1
0
1
0
1 RE-SAMPLING FILTER NCO2 - PHASE OFFSET/DELAY
*
*
*
*
0
0
0
0
0
0
0
1
0
1
1
0 RE-SAMPLING FILTER LEAP COUNTER PERIOD
*
*
*
*
0
0
0
0
0
0
0
1
0
1
1
1 RE-SAMPLING FILTER FREQUENCY UPDATE STROBE
*
*
*
*
0
0
0
0
0
0
0
1
1
0
0
0 CHANNEL SOFT RESET STROBE
*
*
*
*
0
0
0
0
0
0
0
1
1
0
0
1 uP STROBE TO UPDATE DATA PATH REGISTER
*
*
*
*
0
0
0
0
0
0
0
1
1
0
1
0 ADVANCE STROBE
*
*
*
*
0
0
0
0
0
0
0
1
1
0
1
1 RETARD STROBE
*01C -*01E RESERVED
*
*
*
*
0
0
FN6006 Rev 3.00
Aug 2004
0
0
0
0
0
1
1
1
1
1 CHANNEL STATUS REGISTER CLEAR STROBE
Page 29 of 71
ISL5416
TABLE 12. CHANNEL CONTROL REGISTERS (WRITES) (Continued)
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
0
DESCRIPTION
*020 -*07F RESERVED
*
*
*
*
0
0
0
1
0
0
0
0
0
0
0
0 FIR1 COEFFICIENTS
THRU
*
*
*
*
0
0
0
1
0
0
0
1
1
1
1
1
*120 - *1FF RESERVED
*
*
*
*
0
0
1
0
0
0
0
0
0
0
0
0 FIR2 COEFFICIENTS
THRU
*
*
*
*
0
0
1
0
0
0
1
1
1
1
1
1
*240 - *FFF RESERVED
NOTE: The controls marked as “” are double buffered, i.e. the data is loaded into a holding register by the uP and then transferred
to an active register by either a write to an indirect location that generates an update strobe or by a SYNCInX signal if enabled in
IWA = *000h.
TABLE 13. CHANNEL CONTROL REGISTERS (READS)
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
0
*
*
*
*
0
0
0
0
0
0
0
0
0
0
0
0 CONTROL REGISTER *000
*
*
*
*
0
0
0
0
0
0
0
0
0
0
0
1 CONTROL REGISTER *001
*
*
*
*
0
0
0
0
0
0
0
0
0
0
1
0 CARRIER ACTIVE CENTER FREQUENCY
*
*
*
*
0
0
0
0
0
0
0
0
0
0
1
1 CONTROL REGISTER *003
*
*
*
*
0
0
0
0
0
0
0
0
0
1
0
0 N/A (STROBE)
*
*
*
*
0
0
0
0
0
0
0
0
0
1
0
1 CONTROL REGISTER *005
*
*
*
*
0
0
0
0
0
0
0
0
0
1
1
0 CONTROL REGISTER *006
*
*
*
*
0
0
0
0
0
0
0
0
0
1
1
1 CONTROL REGISTER *007
*
*
*
*
0
0
0
0
0
0
0
0
1
0
0
0 CONTROL REGISTER *008
*
*
*
*
0
0
0
0
0
0
0
0
1
0
0
1 CONTROL REGISTER *009
*
*
*
*
0
0
0
0
0
0
0
0
1
0
1
0 CONTROL REGISTER *00A
*
*
*
*
0
0
0
0
0
0
0
0
1
0
1
1 CONTROL REGISTER *00B
*
*
*
*
0
0
0
0
0
0
0
0
1
1
0
0 CONTROL REGISTER *00C
*
*
*
*
0
0
0
0
0
0
0
0
1
1
0
1 CONTROL REGISTER *00D
*
*
*
*
0
0
0
0
0
0
0
0
1
1
1
0 AGC GAIN IS READ AT DIRECT ADDRESSES 4 - 7 AFTER SAMPLING WITH
A WTITE TO IWA = *010h
*
*
*
*
0
0
0
0
0
0
0
0
1
1
1
1 N/A (STROBE)
*
*
*
*
0
0
0
0
0
0
0
1
0
0
0
0 MAGNITUDE (AFTER SAMPLING WITH A WRITE TO THIS LOCATION)
*
*
*
*
0
0
0
0
0
0
0
1
0
0
0
1 ACTIVE RESAMPLER NCO1 FREQUENCY 47:16
*
*
*
*
0
0
0
0
0
0
0
1
0
0
1
0 ACTIVE RESAMPLER NCO1 FREQUENCY 15:0
*
*
*
*
0
0
0
0
0
0
0
1
0
0
1
1 ACTIVE RESAMPLER NCO2 FREQUENCY 47:16
*
*
*
*
0
0
0
0
0
0
0
1
0
1
0
0 ACTIVE RESAMPLER NCO2 FREQUENCY 15:0
*
*
*
*
0
0
0
0
0
0
0
1
0
1
0
1 CONTROL REGISTER *015
*
*
*
*
0
0
0
0
0
0
0
1
0
1
1
0 CONTROL REGISTER *016
*
*
*
*
0
0
0
0
0
0
0
1
0
1
1
1 N/A (STROBE)
*
*
*
*
0
0
0
0
0
0
0
1
1
0
0
0 N/A (STROBE)
FN6006 Rev 3.00
Aug 2004
DESCRIPTION
Page 30 of 71
ISL5416
TABLE 13. CHANNEL CONTROL REGISTERS (READS) (Continued)
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
0
DESCRIPTION
*
*
*
*
0
0
0
0
0
0
0
1
1
0
0
1 N/A (STROBE)
*
*
*
*
1
1
0
1
0 N/A (STROBE)
*
*
*
*
0
0
0
0
0
0
0
1
1
0
1
1 N/A (STROBE)
*
*
*
*
0
0
0
0
0
0
0
1
1
1
0
0 N/A (STROBE)
*01D - *03E UNUSED
*
*
*
*
0
0
0
0
0
0
0
1
1
1
1
1 CHANNEL STATUS
*03F - *07F UNUSED
*
*
*
*
0
0
0
1
0
0
0
0
0
0
0
0 FIR1 COEFFICIENTS
THRU
*
*
*
*
0
0
0
1
0
0
0
1
1
1
1
1
*120 - *1FF UNUSED
*
*
*
*
0
0
1
0
0
0
0
0
0
0
0
0 FIR2 COEFFICIENTS
THRU
*
*
*
*
0
0
1
0
0
0
1
1
1
1
1
1
*240 - *FFF UNUSED
TABLE 14. CHANNEL STATUS BITS (*01Fh) ONCE SET, STATUS BITS STAY SET UNTIL CLEARED BY A WRITE TO *01Fh
BITS
DESCRIPTION
15
FIFO crossed threshold
14
FIFO empty
13
FIFO full
12
Saturation in IHBF (I or Q)
11
Saturation in Q channel 24 -> 16 bit rounder (to FIFO prior to IHBF)
10
Saturation in I channel 24 -> 16 bit rounder (to FIFO prior to IHBF)
9
UNUSED.
8
Saturation in AGC forward gain path (I or Q)
7
Saturation in Q channel FIR2
6
Saturation in I channel FIR2
5
Saturation in Q channel FIR1 to FIR2 gain block
4
Saturation in I channel FIR1 to FIR2 gain block
3
Saturation in Q channel FIR1
2
Saturation in I channel FIR1
1
Saturation in Q channel CIC to FIR1 gain block
0
Saturation in I channel CIC to FIR1 gain block
NOTE: FIR Saturation bits will indicate saturation if an intermediate accumulation exceeds 1.0, even though, the final result is less than 1.0. The
headroom for intermediate sums of products is up to 16 (24).
FN6006 Rev 3.00
Aug 2004
Page 31 of 71
ISL5416
Tables of Top Level Registers
In the tables below “reset state” indicates the register
contents after a HW reset or a SW hard reset. Unless
noted, a soft channel reset does not clear register
contents. A soft channel reset does clear the slave
registers of a master/slave pair (such as channel data path
control) but does not clear the master.
This register controls the output SYNC signal polarity, the
output clock rate and polarity, output data modes, and channel
cascading.
TABLE 15. COMMON OUTPUT CONTROL FUNCTIONS (GWA = 0000h) RESET STATE = 0x00000001h
P(31:0)
FUNCTION
31
ENABLE SERIAL OUTPUT.
1 = serial output mode is enabled. The DOUT parallel data bus is replaced with 4 serial output busses -- one per channel. See 0*06h
- 0*08h and Table 30.
30
RESERVED. Set to 0.
29
SCLK RESET.
1 = serial clock divider is reset by SYNCInX if the reset serial output bit is set in IWA = *000h, bits 13 or 29 of any of the 4 channels.
28
SCLK POLARITY.
1 = Low to High transitions at the center of the data bit.
0 = High to Low transitions at the center of the data bit.
27:25
SCLK RATE.
000 = SCLK DIsabled.
001 = input clock rate.
010 = input clock rate / 2.
011 = input clock rate / 4.
100 = input clock rate / 8.
101 = input clock rate /16.
24:21
RESERVED. Set to 0.
20
ROUTE CHANNEL 2 TO CHANNEL 3.
1 = route the output of FIR2 of channel 2 to the input of the CIC to FIR1 gain block in channel 3.
19
ROUTE CHANNEL 1 TO CHANNEL 2.
1 = route the output of FIR2 of channel 1 to the input of the CIC to FIR1 gain block in channel 2.
18
ROUTE CHANNEL 0 TO CHANNEL 1.
1 = route the output of FIR2 of channel 0 to the input of the CIC to FIR1 gain block in channel 1.
17
CHANNEL 0 EXTERNAL AGC SOURCE SELECT.
0 = when bit 14 is set, Channel 1 controls Channel 0 gain.
1 = when bit 14 is set, Channel 3 controls Channel 0 gain.
16
CHANNEL 2 EXTERNAL/INTERNAL GAIN CONTROL.
1 = Channel 2 gain is controlled by Channel 3.
15
CHANNEL 1 EXTERNAL/INTERNAL GAIN CONTROL.
1 = Channel 1 gain is controlled by Channel 3.
14
CHANNEL 0 EXTERNAL/INTERNAL GAIN CONTROL.
1 = Channel 0 gain is controlled by Channel 3 or Channel 1 depending on the state of bit 17.
13
CLKO2 OR INTRPT.
1 = CLKO2/INTRPT is INTRPT (2 clock period wide pulse).
0 = CLKO2/INTRPT is CLKO2.
NOTE: For INTRPT IWA = 0*0Ah, bit 31 must be set for the channel that is the interrupt source..
12
FSYNCX POLARITY.
0 = active high
1 = active low.
FN6006 Rev 3.00
Aug 2004
Page 32 of 71
ISL5416
TABLE 15. COMMON OUTPUT CONTROL FUNCTIONS (GWA = 0000h) RESET STATE = 0x00000001h
P(31:0)
FUNCTION
11
CLKO2 POLARITY.
1 = Low to High transition in the middle of data period.
0 = High to Low transition in the middle of data period.
If bit 13 is set:
1 = active high interrupt
0 = active low interrupt.
10
CLKO1 POLARITY.
1 = Low to High transition in the middle of data period.
0 = High to Low transition in the middle of data period.
9:8
HOLD CLKO AFTER RESET.
11 = hold CLKO after hard reset until SYNCIn2.
10 = hold CLKO after hard reset until SYNCIn1. (To re-sync the clock after it has been started, disable it by setting these bits to 00
and then set the bits back to 1X and apply SYNCInX).
01 = enable CLKO after programming this register (This applies only when the CLKO rate is NOT equal to CLKIN rate; there is no
need to align the start if CLKO = CLK, and if that is the case, it starts immediately after programming).
00 = disable CLKO.
7:0
CLKO1 RATE.
CLKIN / N for N = 1 to 16.
1 = 0x80h or 0x00h
2 = 0x81h
3 = 0x82h
4 = 0x93h
5 = 0x94h
6 = 0xA5h
7 = 0xA6h
8 = 0xB7h
9 = 0xB8h
10 = 0xC9h
11 = 0xCAh
12 = 0xDBh
13 = 0xDCh
14 = 0xEDh
15 = 0xEEh
16 = 0xFFh
This register (IWA = 0001h) routes the bits from the four range
select blocks to the four nibbles of the Eout bus. Each nibble of
the Eout bus can be controlled by any of the range selectors.
Each range select block contains a mapping table with three
input bits and eight output bits. The three input bits represent 0
to 42 dB of attenuation in 6 dB steps. The programming of the
input to output bit map depends on the type of attenuator or
VGA used. Typically four bits would be sufficient for an
attenuator while 8 bits might be needed for a D/A controlled
VGA.
FN6006 Rev 3.00
Aug 2004
An example programming for 4 bits per attenuator control is:
0x00001357h
range controls A, B, C, and D control Eout bits 15:12, 11:8, 7:4,
3:0, respectively.
For 8 bits per attenuator control:
0x00000145
range controls A and C control Eout bits 15:8 and 7:0,
respectively.
Page 33 of 71
ISL5416
TABLE 16. Eout (RANGE CONTROL) SOURCE SELECT (GWA = 0001h) RESET STATE = 0x00000000h
P(31:0)
FUNCTION
31:16
UNUSED.
15:12
Eout(15:12).
1XXX = set to 0000.
0000 = AH (A range select mapped bits 7:4).
0001 = AL (A range select mapped bits 3:0).
0010 = BH (B range select mapped bits 7:4).
0011 = BL (B range select mapped bits 3:0).
0100 = CH (C range select mapped bits 7:4).
0101 = CL (C range select mapped bits 3:0).
0110 = DH (D range select mapped bits 7:4).
0111 = DL (D range select mapped bits 3:0).
See IWA = 0*17h and 0*18h.
11:8
Eout(11:8).
See bits 15:12.
7:4
Eout(7:4).
See bits 15:12.
3:0
Eout(3:0).
See bits 15:12.
A test register is provided for the processor to input data to the
part. The register can be selected as the input for any or all of
the channels. The test input is 16 bits of data plus 3 bits of
exponent. The input enable is also controllable by the uP. The
choices are always active, always inactive, and one clock wide
input enable each time the uP writes to IWA = 0003h. This last
choice is for inputting test data via the uP interface. The Input
enable choice is done in the channel at IWA = *001h, bits
19:17.
TABLE 17. TEST INPUT DATA REGISTER (GWA = 0002h) RESET STATE = 0x00000000h
P(31:0)
FUNCTION
31:26
RESERVED. Set to 0.
25
RESERVED. Set to 1.
24
RESERVED. Set to 0.
23
ENABLE TESTOUT D(15:0) TO DOUT(15:0). Set to 0 for normal operation. See Table 18 below.
22
ENABLE TESTOUT C(15:0) TO COUT(15:0). Set to 0 for normal operation. See Table 18 below.
21
ENABLE TESTOUT B(15:0) TO BOUT(15:0). Set to 0 for normal operation. See Table 18 below.
20
ENABLE TESTOUT A(15:0) TO AOUT(15:0). Set to 0 for normal operation. See Table 18 below.
19
RESERVED. Set to 0.
18:16
EXPONENT.
000 = add 0 dB of gain.
111 = add 42 dB of gain.
15:0
DATA. Twos complement.
TABLE 18. TESTOUT X(15:0) BUS SIGNALS (CAN BE OR’d WITH NORMAL OUTPUT ON XOUT BY SETTING BITS 23:20, GWA = 0002h)
15
RANGE CONTROL END OF INTEGRATION PERIOD SIGNAL.
14
RANGE CONTROL END OF DELAY SIGNAL
13
RANGE CONTROL COUNTER LOAD SIGNAL (SYNC and slot counter generated)
12
RANGE CONTROL MAGNITUDE GREATER THAN IMMEDIATE THRESHOLD
11
RANGE CONTROL AVERAGE MAGNITUDE GREATER THAN THRESHOLD 2
10
RANGE CONTROL AVERAGE MAGNITUDE SMALLER THAN THRESHOLD 3
9
RESAMPLER NCO2 2X CARRY OUT
FN6006 Rev 3.00
Aug 2004
Page 34 of 71
ISL5416
TABLE 18. TESTOUT X(15:0) BUS SIGNALS (CAN BE OR’d WITH NORMAL OUTPUT ON XOUT BY SETTING BITS 23:20, GWA = 0002h)
8
RESAMPLER NCO1 2X CARRY OUT
7
AGC COUNTER LOAD SIGNAL (SYNC and slot counter generated)
6
AGC END OF DELAY COUNTER
5
AGC LOOP GAIN SELECT SIGNAL
4
AGC UPDATE FORWARD GAIN SIGNAL
3
CARRIER NCO MSB (L.O. TEST POINT)
2:0
FIFO READ ADDRESS (2:0); (FIFO Depth, empty = 0)
TABLE 19. TEST INPUT STROBE (GWA = 0003h) RESET STATE = INACTIVE
N/A
N/A
FUNCTION
STROBE. A write to this location generates a one-clock-wide test input enable (for use with the test input register).
For synchronization of the ISL5416 channels to system
timing and/or to the processing of other ISL5416 channels,
one synchronization output (SYNCO) and two
synchronization inputs (SYNCIn1 and SYNCIn2) are
provided. The SYNCO of one ISL5416 might be connected
to the SYNCIn1 of all the ISL5416s to allow the uP to
synchronously start or update parameters in all of the
ISL5416s. A write to IWA = 0005h also internally routes the
SYNCO to the SYNCIn1 input with the same delay as
connecting the SYNCO pin to the SYNCIn1 pin. For
alignment to system timing, the SYNCInX pins can be
connected to any one-clock-wide signal synchronous to
CLKC. A second synchronization input, SYNCIn2, is
provided to synchronize different channels to different event
or to allow the processor to control certain events and the
system timing to control others.
TABLE 20. SYNCO (GWA = 0004h) RESET STATE = INACTIVE
N/A
N/A
FUNCTION
STROBE. A write to this location generates a one-clock-wide pulse on the SYNCO pin.
TABLE 21. SYNCO WITH INTERNAL FEEDBACK (GWA = 0005h) RESET STATE = INACTIVE
N/A
N/A
FUNCTION
STROBE. A write to this location generates a one-clock-wide pulse on the SYNCO pin that is also internally fed back to the
SYNCIn1 pin.
There are three resets to the ISL5416 -- the reset pin, the
chip hard reset (IWA = 0006h), and the soft channel reset
(IWA = *018h). The pin reset and chip hard reset have the
same effect. The soft channel reset only affects the selected
channel and does not reset the control registers, only the
slave (active) registers of master/slave pairs.
TABLE 22. CHIP HARD RESET VIA SOFTWARE (GWA = 0006h) RESET STATE = INACTIVE
N/A
FUNCTION
N/A
RESET STROBE. Writing to this location generates a hardware reset, resetting all control registers. Identical function to the RESET
pin.
FN6006 Rev 3.00
Aug 2004
Page 35 of 71
ISL5416
Tables of I/O Registers
TABLE 23. CHANNEL INPUT FORMAT (IWA = 0*00h) RESET STATE = 0x00000000h
P(31:0)
31:16
FUNCTION
UNUSED.
15
FIXED GAIN MODE IN VGA.
14
RESERVED. Set to 1.
13
INVERT INPUT CLOCK.
1 = High -> Low edge of the input clock samples input data.
0 = Low -> High edge of the input clock samples input data.
12
INPUT CLOCK SOURCE.
1 = CLKC
0 = CLKA for Ain (address 0000 XXX1 0000 0000)
CLKB for Bin (address 0000 XX1X 0000 0000)
CLKD for Din (address 0000 1XXX 0000 0000)
CLKC is always used for Cin
The rising edge of CLKC is always used for the channel processing and output timing.
11
INPUT FORMAT.
1 = offset binary.
0 = 2’s complement
10
GATED & INTERPOLATED.
1 = input interpolated.
0 = input gated.
9:7
DEMUX DELAY.
000 = no delay, take sample aligned with the enable.
111 = take 7th sample after the enable.
6:5
RESERVED. Set to 0.
4
LSB TO MSB SWAP ON DATA.
1 = input bus reversed MSB for LSB -- XIN(0) = MSB.
0 = input bus normal XIN(16) = MSB
Provided to simplify circuit board routing.
3:2
FIXED/FLOATING POINT MODE.
00 = 16-bit fixed point (bits 16:1, 0 unused).
01 = 14/3 floating point (bits 16:3 mantissa, 2:0 exponent).
10 = 15/2 floating point (bits 16:2 mantissa, 1:0 exponent).
11 = 16/1 floating point (bits 16:1 mantissa, 0 exponent).
1:0
RESERVED. Set to 0.
FN6006 Rev 3.00
Aug 2004
Page 36 of 71
ISL5416
TABLE 24. XOUT DATA VERSUS TIME SLOT ROUTING, TIME SLOTS 0, 1 (IWA = 0*01h) RESET STATE = 0x00000000h
X = A, B, C, D (Descriptions below are for the channels 0/1 multiplexer IWA = 0101h (MUX 01AC). See figure 10 for corresponding
signals and buses for the other multiplexers)
P(31:0)
FUNCTION
31:30
RESERVED. Set to 0.
29:28
XOUT TIMING SOURCE. The output slot counter is started by a new sample from
00 = Channel 0
01 = Channel 1
10 = Channel 2
11 = Channel 3
This allows two output busses to be used by one channel if the other channel is disabled.
27
INVERT (ONES COMPLEMENT) XOUT BUS.
1 = ones complement XOUT(15:0). By setting this bit for BOUT or DOUT, the AOUT and BOUT and/or COUT and DOUT can provide
complementary output signals.
26
ASSERT FSYNCX DURING SLOT 1.
1 = assert FSYNCX for this time slot.
0 = no FSYNCX.
25
ENABLE TO Cout DURING SLOT 1. (OE_01C)
1 = route the data selected in 23:16 and SYNC enabled in bit 26 to the Cout and SYNCC pins. Provided for multiplexing A and B with
C and D channels.
24
ENABLE TO Aout DURING SLOT 1. (OE_01A)
1 = route the data selected in 23:16 and SYNC enabled in bit 26 to the Aout and SYNCA pins. Provided for multiplexing A and B with
C and D channels.
23:20
SLOT 1, HIGH BYTE. Data output from the A high byte multiplexer for slot 1. See Table 29 for coding.
19:16
SLOT 1, LOW BYTE. Data output from the A low byte multiplexer for slot 1. See Table 29 for coding.
15:11
RESERVED. Set to 0.
10
ASSERT FSYNCX DURING SLOT 0.
1 = assert FSYNCX for this time slot.
0 = no FSYNCX.
9
ENABLE TO Cout DURING SLOT 0.
1 = route the data selected in 7:0 and SYNC enabled in bit 10 to the Cout and SYNCC pins. Provided for multiplexing A and B with
C and D channels.
8
ENABLE TO Aout DURING SLOT 0.
1 = route the data selected in 7:0 and SYNC enabled in bit 10 to the Aout and SYNCA pins. Provided for multiplexing A and B with
C and D channels.
7:4
SLOT 0, HIGH BYTE. Data output from the A high byte multiplexer for slot 0. See Table 29 for coding.
3:0
SLOT 0, LOW BYTE. Data output from the A low byte multiplexer for slot 0. See Table 29 for coding.
TABLE 25. XOUT DATA VERSUS TIME SLOT ROUTING, TIME SLOTS 2, 3 (IWA = 0*02h) RESET STATE = 0x00000000h
P(31:0)
FUNCTION
31:27
RESERVED. Set to 0.
26:16
SLOT 3 CONTROL (see Table 24)
15:11
RESERVED. Set to 0.
10:0
SLOT 2 CONTROL (see Table 24)
TABLE 26. XOUT DATA VERSUS TIME SLOT ROUTING, TIME SLOTS 4, 5 (IWA = 0*03h) RESET STATE = 0x00000000h
P(31:0)
FUNCTION
31:27
RESERVED. Set to 0.
26:16
SLOT 5 CONTROL (see Table 24)
15:11
RESERVED. Set to 0.
10:0
SLOT 4 CONTROL (see Table 24)
FN6006 Rev 3.00
Aug 2004
Page 37 of 71
ISL5416
TABLE 27. XOUT DATA VERSUS TIME SLOT ROUTING, TIME SLOTS 6, 7 (IWA = 0*04h) RESET STATE = 0x00000000h
P(31:0)
FUNCTION
31:27
RESERVED.
26:16
SLOT 7 CONTROL (see Table 24)
15:11
RESERVED.
10:0
SLOT 6 CONTROL (see Table 24)
The ISL5416 can be programmed to respond to the
synchronization inputs, SYNCIn1 and SYNCIn2, in a number
of ways. This register controls the range control response to
the SYNC inputs. The response of the channels to the SYNC
inputs is controlled by IWA = *000h. CLKO start up from
SYNCIn1 or SYNCIn2 is controlled in IWA = 0000h.
TABLE 28. INPUT SYNCIn1/SYNCIn2 FUNCTION SELECT (IWA = 0*05h) RESET STATE = 0x00000000h
P(31:0)
31
30:20
FUNCTION
ENABLE SYNCIn2 TO RANGE CONTROL.
1 = range control block responds to SYNCIn2 according to bits 19:16 settings.
0 = range control block does not respond to SYNCIn2.
RESERVED. Set to 0.
19
READ UPDATE ON SYNCIn2.
1 = attenuator control accumulator contents are transferred to the read holding register on SYNCIn2.
18
LOAD ACCUMULATOR ON SYNCIn2.
1 = attenuator control accumulator is loaded from the uP load register (0*19) on a SYNCIn2.
17
RANGE CONTROL STARTUP ON SYNCIn2.
1 = enable range control on SYNCIn2 if 0*10, bit 1 is set. Range control is disabled on reset or by writing a zero to IWA = 0*10h, bit
0. If this bit is set, bit 0 of 0*10 is set on a SYNCIn2.
16
TIMING RESET ON SYNCIn2.
1 = reset range control timing on SYNCIn2 if 0*10, bit 1 is set. Once started, the timers will run until disabled (bit 1 of 0*10h or HW
reset).
15
ENABLE SYNCIn1 TO RANGE CONTROL.
1 = range control block responds to SYNCIn1 according to bits 3:0 settings.
0 = range control block does not respond to SYNCIn1.
14:4
RESERVED. Set to 0.
3
READ UPDATE ON SYNCIn1.
1 = attenuator control accumulator contents are transferred to the read holding register on SYNCIn1.
2
LOAD ACCUMULATOR ON SYNCIn1.
1 = attenuator control accumulator is loaded from the uP load register (0*19) on a SYNCIn1.
1
RANGE CONTROL STARTUP ON SYNCIn1.
1 = enable VGA startup control on SYNCIn2 if 0*10, bit 1 is set. Range control is disabled on reset or by writing a zero to 0*10, bit 0.
If this bit is set, bit 0 of 0*10 is set on a SYNCIn1. Disable on reset.
0
TIMING RESET ON SYNCIn1.
1 = reset range control timing on SYNCIn1 if 0*10, bit 1 is set. Once started, the timers will run until disabled (bit 1 of 0*10h or HW
reset).
FN6006 Rev 3.00
Aug 2004
Page 38 of 71
ISL5416
TABLE 29. HIGH, LOW BYTE DATA TYPE CODES (AFTER
ROUNDING IN THE CHANNEL)
CODE
CHANNEL 0, CHANNEL CHANNEL 2, CHANNEL
1 MUXES
3 MUXES
0000
CH 0 I(23:16)
CH 2 I(23:16)
0001
CH 0 I(15:8)
CH 2 I(15:8)
0010
CH 0 I(7:0)
CH 2 I(7:0)
0011
CH 0 Q(23:16)
CH 2 Q(23:16)
0100
CH 0 Q(15:8)
0101
Serial Output:
When bit 31 of GWA = 0000h is set, the DOUT bus is used for
serial outputs.
Four bits are allocated to each channel as follows:
TABLE 30. SERIAL OUTPUT BITS ALLOCATION
CHANNEL 0
CHANNEL 1
CHANNEL 2
CHANNEL 3
SCLKX
DOUT0
DOUT4
DOUT8
DOUT12
CH 2 Q(15:8)
SSYNCX
DOUT1
DOUT5
DOUT9
DOUT13
CH 0 Q(7:0)
CH 2 Q(7:0)
SD1X
DOUT2
DOUT6
DOUT10
DOUT14
0110
CH 0 AGC(15:8)
CH 2 AGC(15:8)
SD2X
DOUT3
DOUT7
DOUT11
DOUT15
0111
CH 0 AGC(7:0)
CH 2 AGC(7:0)
1000
CH 1 I(23:16)
CH 3 I(23:16)
1001
CH 1 I(15:8)
CH 3 I(15:8)
1010
CH 1 I(7:0)
CH 3 I(7:0)
1011
CH 1 Q(23:16)
CH 3 Q(23:16)
1100
CH 1 Q(15:8)
CH 3 Q(15:8)
1101
CH 1 Q(7:0)
CH 3 Q(7:0)
1110
CH 1 AGC(15:8)
CH 3 AGC(15:8)
1111
CH 1 AGC(7:0)
CH 3 AGC(7:0)
A common serial clock generator is used for all four outputs, so
the four SCLKs are synchronous. Four separate outputs are
provided to simplify PWB routing. Each SCLK output can be
separately enabled, so that unused clock outputs can be turned
off.
Serial outputs are always MSB first.
Addresses 0106h to 0108h control the serial output from
channel 0.
Addresses 0206h to 0208h control the serial output from
channel 1.
Addresses 0406h to 0408h control the serial output from
channel 2.
Addresses 0806h to 0808h control the serial output from
channel 3.
FN6006 Rev 3.00
Aug 2004
Page 39 of 71
ISL5416
TABLE 31. SERIAL OUTPUT CONTROL (IWA = 0*06h) RESET STATE = 0x00000000h
P(31:0)
31:30
FUNCTION
RESERVED. Set to 0.
29
SCLK ENABLE.
1 = enable
The serial clock generator is shared by the four serial outputs. A serial clock pin is provided for each output. Each pin can be enabled
or disabled independent of the other channels.
28
SSYNCX POLARITY.
1 = Active Low.
0 = Active High.
The SSYNCX signal is asserted for one serial clock period for each time slot where SSYNC is enabled.
27:26
RESERVED. Set to 0.
25:24
SSYNCX POSITION.
00 = Early SSYNC. SSYNCX is asserted during the serial clock period prior to the first data bit for each slot where SSYNC is enabled.
01 = Late SSYNC. SSYNCX is asserted during the serial clock period following the last data bit for each slot where SSYNC is enabled.
1X = Coincident SSYNC. SSYNCX is asserted during the serial clock period of first data bit for each slot where SSYNC is enabled.
23:20
RESERVED. Set to 0.
19:16
SD1X ROUTING MASK.
These bits gate the serial output of each channel to any or all 4 serial output pins. The gated serial outputs from all of the channels
are ORed together. This allows channels to be multiplexed together on a single serial output by offsetting the serial data streams from
each other using the hold off delay below or by using empty time slots. Note that the serial data from each channel is zeroed after all
of the slots have been output, so it will not interfere with a delayed channel. The multiplexing of the SSYNCX signals matches the
data multiplexing.
19 - Enable the serial output to the SD1D pin.
18 - Enable the serial output to the SD1C pin.
17 - Enable the serial output to the SD1B pin.
16 - Enable the serial output to the SD1A pin.
15:12
SD2X ROUTING MASK.
15 - Enable the serial output to the SD2D pin.
14 - Enable the serial output to the SD2C pin.
13 - Enable the serial output to the SD2B pin.
12 - Enable the serial output to the SD2A pin.
11:0
OUTPUT HOLD OFF DELAY.
These bits control a programmable hold off delay from the time a set of data samples is provided to the serial output section to the
time that the serial output begins. The delay is programmed in serial clocks. Program with the desired number of serial clocks:
0 = no delay
TABLE 32. SERIAL OUTPUT SD1X SLOT CONTROL (IWA = 0*07h) RESET STATE = 0x00000000h
P(31:0)
31
30:27
FUNCTION
SLOT 4 SYNC ENABLE.
1 = SSYNCX active for this time slot
0 = no SSYNCX for this time slot
SLOT 4 WORD WIDTH.
0000 = 0-bit*
0001 = 4-bit
0010 = 6-bit
0011 = 8-bit
0100 = 10-bit
0101 = 12-bit
0110 = 16-bit
0111 = 20-bit
1000 = 24-bit
1001 = 32-bit (8 LSBs zeroed)
All other codes are invalid. Note that if the channel output is rounded to fewer than 24 bits and fewer than 24 bits is selected for the
slot width, the output will be doubly rounded.
* if 0-bit is selected for slot 1, 2, or 3, one SCLK period will actually be used, though no data will be output.
FN6006 Rev 3.00
Aug 2004
Page 40 of 71
ISL5416
TABLE 32. SERIAL OUTPUT SD1X SLOT CONTROL (IWA = 0*07h) RESET STATE = 0x00000000h
P(31:0)
FUNCTION
26:24
SLOT 4 DATA TYPE.
000 = zeros.
001 = I
010 = Q
011 = AGC (real time).
23:16
SLOT 3. See bits 31:24.
15:8
SLOT 2. See bits 31:24.
7:0
SLOT 1. See bits 31:24.
TABLE 33. SERIAL OUTPUT SD2X SLOT CONTROL (IWA = 0*08h) RESET STATE = 0x00000000h
P(31:0)
31
FUNCTION
RESERVED, Set to 0.
30:27
SLOT 4 WORD WIDTH.
0000 = 0-bit*
0001 = 4-bit
0010 = 6-bit
0011 = 8-bit
0100 = 10-bit
0101 = 12-bit
0110 = 16-bit
0111 = 20-bit
1000 = 24-bit
1001 = 32-bit (8 LSBs zeroed)
All other codes are invalid. Note that if the channel output is rounded to fewer than 24 bits and fewer than 24 bits is selected for the
slot width, the output will be doubly rounded.
* if 0-bit is selected for slot 1, 2, or 3, one SCLK period will actually be used, though no data will be output.
26:24
SLOT 4 DATA TYPE.
000 = zeros.
001 = I
010 = Q
011 = AGC (sampled real time, not sampled by P write or real time updated every AGC input).
23:16
SLOT 3. See bits 31:24.
15:8
SLOT 2. See bits 31:24.
7:0
SLOT 1. See bits 31:24.
TABLE 34. RANGE CONTROL DC BLOCKING FILTER CONTROL (IWA = 0*09h) RESET STATE = 0x00000000h
P(31:0)
31:19
18
FUNCTION
RESERVED. Set to 0.
DC FILTER DISABLE.
1 = Clear filter based DC offset, shut off filter
17:16
DC FILTER GAIN.
00 = Widest
01 = Medium
10 = Narrowest (roughly 120 Hz HPF at 61.44 MSPS)
11 = use P programmed DC offset value
15:0
P LOADED DC OFFSET. Twos Complement. These bits are subtracted from the 16 mantissa bits. Bit 15 has the same weighting
as XIN16 (MSB).
FN6006 Rev 3.00
Aug 2004
Page 41 of 71
ISL5416
A/D Range Control Registers
The range control registers will be explained later in:
The range control section monitors the output of the A/D and
adjusts the RF/IF gain to maintain a desired A/D output range.
The gain adjustments are in 6 dB steps. The levels, adjustment
rates, and gain to bit mapping are programmable.
IWA = 0*09h - 0*16h and IWA = 0*19h - 0*1Dh
A code is programmed for output on the EOUT bus for each of
the eight states of the three MSBs of the attenuator control
register. These codes can be up to 8 bits, but if four gain
control sections are used, only four bits are available for each
gain control section. The routing of the gain control bits to
EOUT bits is done in IWA = 0001h.
Direct addresses 4-7 have a sequenced read mode for quickly
reading I/Q output data, real time AGC gain, sampled AGC
gain, or range control data. The read order is programmed in
this register. The arrival of a new channel output sample resets
the read pointer to the first data type. The rising edge of the RD
signal (or DSTRB with RD/WR high in uP mode 1) will advance
the pointer for that channel to the next data to get it set up at
the interface for fast access. The CLKO2 signal can be
programmed as an interrupt signal for this mode (see GWA =
0000h, bit 13) to tell the processor when there is a new data.
Alternatively, the frame strobe signals from the channels can
be used.
TABLE 35. P SEQUENCED READ MODE, READ ORDER SELECT (IWA = 0*0Ah) RESET STATE = 0x00000000h
P(31:0)
31
FUNCTION
1 = Generate an interrupt with each new data output for this channel.
30:28
READ EIGHT. See bits 3:0. Mask off the MSB of the code.
27:24
READ SEVEN. See bits 3:0.
23:20
READ SIX. See bits 3:0.
19:16
READ FIVE. See bits 3:0
15:12
READ FOUR. See bits 3:0
11:8
READ THREE. See bits 3:0
7:4
READ TWO. See bits 3:0
3:0
READ ONE. (FIRST READ).
0000 = AGC Gain -- sampled by a write to IWA = *010h
0001 = AGC Gain -- real time (updated with every I/Q)
0010 = Q(7:0), 8 zeros
0011 = Q(24:8)
0100 = I(7:0), 8 zeros
0101= I(24:8)
0110 = range control I&D (see IWA = 0*1Ch)
0111 = range accumulator (see IWA = 0*1Bh)
Note that the I/Q data will be rounded to the number of bits programmed in IWA = *001h bits 5:3, and the real time AGC data will have
the format selected in IWA = *001h, bits 2:0.
TABLE 36. ADC RANGE CONTROL -- MAIN (IWA = 0*10h) RESET STATE = 0x00000000h
P(31:0)
FUNCTION
31:24
IMMEDIATE HOLD OFF.
Delay in clock cycles after the immediate threshold adjustment before another adjustment is allowed (00000000 = 1 clock delay). Load
with the desired value minus one.
23:16
UPDATE EXPONENT DELAY.
Delay in clock cycles from a change in the VGA value before it is added to the input exponent value. This should be set to equal the
RF/ADC plus the ISL5416 pipeline delays (6 clocks).
15
DISABLE ACCUMULATOR UPDATES.
1 = disable range control accumulator updates. uP can still load.
FN6006 Rev 3.00
Aug 2004
Page 42 of 71
ISL5416
TABLE 36. ADC RANGE CONTROL -- MAIN (IWA = 0*10h) RESET STATE = 0x00000000h (Continued)
P(31:0)
14
FUNCTION
TIME USING CLOCKS/SAMPLES.
Count intervals and delays using clocks or input enables.
1 = clocks.
0 = input enables.
13:11
UPPER LIMIT.
Upper attenuator control limit, 0 to 42 dB in 6 dB steps.
000 = 0 dB.
111 = 42 dB.
10:8
LOWER LIMIT.
Lower attenuator control limit, 0 to 42 dB in 6 dB steps.
000 = 0 dB.
111 = 42 dB.
7:4
NORMALIZATION SHIFT/DIVIDE SELECT.
Normalizing shifter control. Divides the integrated magnitude by 2N prior to threshold comparison:
accumulator input bits:
20 . . . 2-15
accumulator output bits:
216 . . . 2-15
0000 = select 21 to 2-14
1111 = select 216 . . .to 21
3
ENABLE INPUT EXPONENT BITS.
Enable the exponent bits from the input to be added to the attenuation control bits and routed to the channel(s).
2
ENABLE RANGE CONTROL EXPONENT BITS.
Enable the attenuator control register (accumulator MSBs) bits to be added to the exponent bits from the input and routed to the
channel(s).
1
ENABLE RANGE CONTROL.
1 = enable the range control.
0 = disable the range control (including timers).
0
ENABLE RANGE CONTROL BITS
Enable changes in the attenuator control register (if this bit is cleared, the timers still run but changes to the register are inhibited.
NOTE:
The range control can be enabled by writing to bit 0 or bit 0 can be set by SYNCInX to start updates. See IWA = 0*05h. Timing reset
by SYNCInX is enabled by bits 0 and 16 of IWA = 0*05h.
TABLE 37. TIME SLOT PERIOD, DELAY FROM SYNCInX TO START OF INTEGRATION (IWA = 0*11h) RESET STATE = 0x00000000h
THIS CONTROL IS SHARED FOR AIN/BIN AND FOR CIN/DIN
P(31:0)
FUNCTION
31:16
SYNC DELAY.
Delay from SYNC (external or counter generated) to the start of integration. Range of delay is 1 to 65536, load with the desired value
minus 1. Delay in input samples or clocks as selected by bit 14, IWA = 0*10h.
15:0
SLOT PERIOD.
Time interval between counter generated SYNCs in samples or clocks as selected by bit 14, IWA = 0*10h. Range for period is 2 to
65536, load with period minus 1.
TABLE 38. NUMBER OF INTEGRATIONS PER SLOT, INTEGRATION TIME (IWA = 0*12h) RESET STATE = 0x00000000h
THIS CONTROL IS SHARED FOR AIN/BIN AND FOR CIN/DIN
P(31:0)
FUNCTION
31:16
NUMBER OF INTEGRATIONS PER SLOT.
Number of input magnitude integration periods per slot. Range is 1 to 32768, load with number of integrations minus 1.
15:0
INTEGRATION TIME.
Number of input samples to average before making an upper or lower threshold decision in samples or clocks as selected by bit 14,
IWA = 0*10h. Range is 2 to 65536, load with samples minus 1.
FN6006 Rev 3.00
Aug 2004
Page 43 of 71
ISL5416
TABLE 39. LOWER THRESHOLD, ATTENUATOR CHANGE (IWA = 0*13h) RESET STATE = 0x00000000h
THIS CONTROL IS SHARED FOR AIN/BIN AND FOR CIN/DIN
P(31:0)
FUNCTION
31:30
RESERVED. Set to 0.
29:16
ATTENUATION STEP 3.
Amount to decrease the attenuation control register if the average input magnitude is below the lower threshold. 14-bit value loads
the LSBs of a 17-bit accumulator. The 3 MSBs of the 17-bit load are hard-wired to “111” , so the load value should be masked from
a negative number. The MSB of the 14-bit value is weighted at 6 dB so the value at all zeros would be ~12 dB (decrease in
attenuation).
15:0
THRESHOLD 3.
Lower threshold value. If the accumulated and normalized input magnitude is below this value, the attenuation control accumulator is
adjusted by the amount programmed in bits 29:16.
TABLE 40. UPPER THRESHOLD, ATTENUATOR CHANGE (IWA = 0*14h) RESET STATE = 0x00000000h
THIS CONTROL IS SHARED FOR AIN/BIN AND FOR CIN/DIN
P(31:0)
FUNCTION
31:30
RESERVED. Set to 0.
29:16
ATTENUATION STEP 2.
Amount to increase the attenuation control register if the average input magnitude is above the upper threshold. 14-bit value loads
the LSBs of a 17-bit accumulator. The 3 MSBs of the 17-bit load are hard-wired to “000” . The MSB of the 14-bit value is weighted at
6 dB so the value at all ones would be ~12 dB (increase in attenuation).
15:0
THRESHOLD 2.
Upper threshold value. If the accumulated and normalized input magnitude is above this value, the attenuation control accumulator
is adjusted by the amount programmed in bits 29:16.
TABLE 41. IMMEDIATE THRESHOLD, ATTENUATOR GAIN (IWA = 0*15h) RESET STATE = 0x00000000h
THIS CONTROL IS SHARED FOR AIN/BIN AND FOR CIN/DIN
P(31:0)
FUNCTION
31:30
RESERVED. Set to 0.
29:16
ATTENUATION STEP 1.
Amount to increase the attenuation control register if the sample-by-sample input magnitude is above the immediate threshold. 14bit value loads the LSBs of a 17-bit accumulator. The 3 MSBs of the 17-bit load are hard-wired to “000” . The MSB of the 14-bit value
is weighted at 6 dB so the value at all ones would be ~12 dB (increase in attenuation). This change happens immediately. Subsequent
changes due to crossing this threshold are held off by the delay in location IWA = 0*10, bits 31:24.
15:0
THRESHOLD 1.
Immediate threshold value. If the input magnitude is above this value, the attenuation control accumulator is adjusted by the amount
programmed in bits 29:16.
NOTES ON THRESHOLDS:
The input range is -32768 to 32767 (0x8000 to 0x7FFF)
The magnitude range is 0 to 32768 ( 0x0000 to 0x8000)
The immediate threshold is 0 to 65536 (0x0000 to 0xFFFF)
The magnitude must be greater than the immediate threshold to trigger.
The integration period is 2 to 216.
The integrated magnitude range is 0x00000000 to 0x80000000
The normalization divider range is 21 to 216, so with the maximum dividers:
The averaged output is 0x0000 to 0x8000
The upper and lower thresholds are 0 to 65536 (0x0000 to 0xFFFF)
To trigger the upper and lower comparisons:
The magnitude must be greater than the upper threshold.
The magnitude must be less than lower threshold.
FN6006 Rev 3.00
Aug 2004
Page 44 of 71
ISL5416
NOTES ON LOADING AND READING THE RANGE CONTROL ACCUMULATOR:
Master Bus -> Holding Register -> Accumulator -> Holding Register
The accumulator is 17 bits. The lower 16 bits are loaded from the micro-processor interface master register into a holding register.
The MSB of the input holding register is always zero. The accumulator is loaded from the holding register. When the accumulator is
read, the most significant 16 accumulator bits are returned (the LSB of the accumulator is not read).
TABLE 42.
ACCUMULATOR
16:0
MASTER
15:0
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
IWA = 0*19h
Z, 15:0
0
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
IWA = 0*1Bh
16:1
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Range Control bit weights are listed in Table 85 in the back of
the data sheet.
TABLE 43. LEAK FACTOR (BIAS) (IWA = 0*16h) RESET STATE = 0x00000000h THIS CONTROL IS SHARED FOR AIN/BIN AND FOR
CIN/DIN
P(31:0)
FUNCTION
31:16
UNUSED.
15:0
LEAK FACTOR.
This signed value is added to the attenuator control register if the average input magnitude is between the upper and lower thresholds
when updates are enabled (at the end of integration)
S [ S -1 . . . -15 ] into the 17-bit accumulator. MSB of 16 programmable bits (S) has a weight of -24 dB.
TABLE 44. GAIN MAPPING LOOK-UP TABLE REGISTER 1 (IWA = 0*17h) RESET STATE = 0x00000000h
P(31:0)
FUNCTION
31:24
ATTENUATION CODE 3 (18 dB code). 8 bit output code when the attenuation register MSBs = 011b. See output E routing control
for bit to pin mapping.
23:16
ATTENUATION CODE 2 (12 dB code). 8 bit output code when the attenuation register MSBs = 010b. See output E routing control
for bit to pin mapping.
15:8
ATTENUATION CODE 1 (6 dB code). 8 bit output code when the attenuation register MSBs = 001b. See output E routing control for
bit to pin mapping.
7:0
ATTENUATION CODE 0 (0 dB code). 8 bit output code when the attenuation register MSBs = 000b. See output E routing control for
bit to pin mapping.
TABLE 45. GAIN MAPPING LOOK-UP TABLE REGISTER 2 (IWA = 0*18h) RESET STATE = 0x00000000h
P(31:0)
FUNCTION
31:24
ATTENUATION CODE 7 (42 dB code). 8 bit output code when the attenuation register MSBs = 111b. See output E routing control
for bit to pin mapping.
23:16
ATTENUATION CODE 6 (36 dB code). 8 bit output code when the attenuation register MSBs = 110b. See output E routing control
for bit to pin mapping.
15:8
ATTENUATION CODE 5 (30 dB code). 8 bit output code when the attenuation register MSBs = 101b. See output E routing control
for bit to pin mapping.
7:0
ATTENUATION CODE 4 (24 dB code). 8 bit output code when the attenuation register MSBs = 100b. See output E routing control
for bit to pin mapping.
TABLE 46. P ATTENUATOR CONTROL ACCUMULATOR LOAD (IWA = 0*19h) RESET STATE = 0x00000000h
P(31:0)
31:16
FUNCTION
RESERVED. Set to 0.
FN6006 Rev 3.00
Aug 2004
Page 45 of 71
ISL5416
TABLE 46. P ATTENUATOR CONTROL ACCUMULATOR LOAD (IWA = 0*19h) RESET STATE = 0x00000000h
P(31:0)
15:0
FUNCTION
ATTENUATOR LOAD VALUE.
uP loading of attenuator control. MSB = 24 dB, next-MSB = 12 dB, etc. Only top three bits are used to address the look-up table.
TABLE 47. P ATTENUATOR CONTROL ACCUMULATOR LOAD STROBE (IWA = 0*1Ah) RESET STATE = INACTIVE
P(31:0)
FUNCTION
N/A
A write to this location generates a one-clock-wide strobe that transfers the P attenuator control register preload from IWA = 0*19h
to the accumulator. The transfer can also be caused by a SYNCInX signal (see IWA = 0*05h)
TABLE 48. P ATTENUATOR CONTROL ACCUMULATOR READ STROBE (IWA = 0*1Bh) RESET STATE = INACTIVE
P(31:0)
FUNCTION
N/A
A write to this location generates a one-clock-wide strobe that transfers the contents of the attenuator control accumulator to a holding
register to stabilize it for uP reading. The transfer can also be caused by a SYNCInX signal (see IWA = 0*05h). MSB = 48 dB (always
zero).
NOTE: 0x8000h is written to IWA = 0*19h is read 0x4000 here.
TABLE 49. P RANGE CONTROL STATUS READ STROBE (IWA = 0*1Ch) RESET STATE = INACTIVE
P(31:0)
N/A
FUNCTION
A write to this location generates a one-clock-wide strobe that transfers the contents of the range control (averaging) accumulator
after normalization to a holding register to stabilize it for uP reading.
bit 16 - 1 = Immediate threshold crossed since last read.
15:0 - Integrated magnitude after normalization (comparison value for average magnitude thresholds).
TABLE 50. P RANGE CONTROL DC OFFSET READ STROBE (IWA = 0*1Dh) RESET STATE = INACTIVE
P(31:0)
FUNCTION
N/A
A write to this location generates a one-clock-wide strobe that transfers the contents of the range control DC offset filter accumulator
to a holding register to stabilize it for uP reading.
21:0 - Signed DC offset value +/- 0.25 * FULL SCALE (input) range.
FN6006 Rev 3.00
Aug 2004
Page 46 of 71
ISL5416
Tables of Channel Indirect Write Address Registers
The response of the channels to the SYNCIn1 and SYNCIn2
inputs is controlled by IWA *000h. Bits 31:16 control the
response to SYNCIn2 and bits 15:0 control the response to
SYNCIn1. Most processing blocks can be individually reset by
a SYNC. Some control registers are double buffered with the
uP loading a master register and the data transfer to a
slave/active register occurring on either a write to a strobe IWA
location or on a SYNCInX signal. Updating with a SYNCInX
signal allows the functions in more than one ISL5416 to be
updated simultaneously.
SET BITS TO 1 TO ENABLE.
.
TABLE 51. CHANNEL RESET/SYNCIn1, SYNCIn2 CONTROL (IWA = *000h) RESET STATE = 0x00000000h
P(31:0)
FUNCTION
31
CHANNEL SYNCIn2 ENABLE. Enables channel overall response to SYNCIn2.
30
RESERVED. Set to 0.
29
SERIAL OUTPUT. Reset the serial output section on SYNCIn2. This will reset the serial clock divider if GWA = 0000h, bit 29 is set.
28
FIFO. Reset the FIFO at the IHBF/Resampler input on SYNCIn2.
27
LEAP COUNTER. Reset the IHBF/Resampler leap counter on SYNCIn2.
26
RESAMPLER NCOs. Reset back end - resampler NCOs on SYNCIn2.
25
FIFO/INTERPOLATION HALF BAND FILTER/RESAMPLER. Reset back end (Interpolation Half Band Filter, Resampler, Decimation
Counter, and FIFO) on SYNCIn2.
24
AGC RESET. Resets AGC processing on SYNCIn2 and sets the AGC gain to 0 dB (or to the lower limit if greater than 0 dB).
23
AGC TIMING. Resets AGC timing on SYNCIn2.
22
FIR2 RESET. Resets FIR2 on SYNCIn2. Resets the datapath registers and decimation counter.
21
FIR1 RESET. Resets FIR1 on SYNCIn2. Resets the datapath registers and decimation counter.
20
CIC RESET. Resets the CIC on SYNCIn2.
19
RESAMPLER UPDATE. Update (start) the resampler NCOs frequency from the master/holding register to the slave/active register
on SYNCIn2.
18
AGC GAIN LOAD. Update/load AGC gain from the master/holding register to the slave/active register on SYNCIn2.
17
CARRIER CENTER FREQUENCY UPDATE. Updates Carrier Center Frequency from the master/holding register to the slave/active
register on SYNCIn2.
16
DATA PATH UPDATE. Update channel processing control register (*001) from the master/holding register to the slave/active
register on SYNCIn2.
15
CHANNEL SYNCIn1 ENABLE. Enables channel overall response to SYNCIn1.
14
RESERVED. Set to 0.
13
SERIAL OUTPUT. Reset the serial output section on SYNCIn1. This will reset the serial clock divider if GWA = 0000h, bit 29 is set.
12
FIFO. Reset the FIFO at the IHBF/Resampler input on SYNCIn1.
11
LEAP COUNTER. Reset the IHBF/Resampler leap counter on SYNCIn1.
10
RESAMPLER NCOs. Reset back end - resampler NCOs on SYNCIn1.
9
FIFO/INTERPOLATION HALF BAND FILTER/RESAMPLER. Reset back end (Interpolation Half Band Filter, Resampler, Decimation
Counter, and FIFO) on SYNCIn1.
8
AGC RESET. Resets AGC processing on SYNCIn1 and sets the AGC gain to 0 dB (or to the lower limit if greater team 0 dB).
7
AGC TIMING. Resets AGC timing on SYNCIn1.
6
FIR2 RESET. Resets FIR2 on SYNCIn1. Resets the datapath registers and decimation counter.
5
FIR1 RESET. Resets FIR1 on SYNCIn1. Resets the datapath registers and decimation counter.
4
CIC RESET. Resets the CIC on SYNCInq1.
3
RESAMPLER UPDATE. Update (start) resampler NCOs frequency from the master/holding register to the slave/active register on
SYNCIn1.
FN6006 Rev 3.00
Aug 2004
Page 47 of 71
ISL5416
TABLE 51. CHANNEL RESET/SYNCIn1, SYNCIn2 CONTROL (IWA = *000h) RESET STATE = 0x00000000h (Continued)
P(31:0)
FUNCTION
2
AGC GAIN LOAD. Update/load AGC gain from the master/holding register to the slave/active register on SYNCIn1.
1
CARRIER CENTER FREQUENCY UPDATE. Updates Carrier Center Frequency from the master/holding register to the
slave/active register on SYNCIn1.
0
DATA PATH UPDATE. Update channel processing control register (*001) on SYNCIn1.
The channel processing control register enables and disables
the major processing blocks in the channel. This register is
double buffered. On reset, the slave/active register is cleared,
disabling the processing in the channel. The processing is
enabled by updating the slave register with either a write to
location IWA *019h or by a SYNCIn signal, if enabled (see IWA
*000h).
TABLE 52. CHANNEL PROCESSING CONTROL (IWA = *001h) RESET STATE = 0x00000000h
P(31:0)
FUNCTION
31:29
COF ENABLE. This is a serial carrier offser frequency control loaded through the DIN bus at the clock rate. The serial bits are shown
in table 53. MSB justified with unused LSBs zeroed. COF is shifted in one bit per clock, MSB first. COFSYNC is one-clock-wide,
active high pulse, asserted during the clock period before the first bit (MSB). The offset frequency is added to the center frequency
loaded by the P. The offset word is a 32-bit twos complement value.
0XX = disabled.
100 = 8 bits offset.
101 = 16 bits offset.
110 = 24 bits offset.
111 = 32 bits offset.
TABLE 53. COF and COFSYNC to DIN BIT
MAPPING
28:23
CHANNEL
COF
COFSYNC
0
DIN16
DIN15
1
DIN12
DIN11
2
DIN8
DIN7
3
DIN4
DIN3
RESERVED. Set to 0.
22
HOIF INTERPOLATE BY 1.
1 = Set this bit to enable HOIF in the IHBF/RESAMPLER block. This is provided to use the HOIF as a phase (time) shift with no rate
change.
21
AGC BYPASS.
1 = bypass AGC;
0 = AGC enabled.
20
AGC TIMER ENABLE.
1 = timing counters in the AGC are enabled.
0 = timing counters in the AGC are disabled.
Note: Counters must be enabled if one of the timed modes is selected in register IWA = *008h.
19:17
CHANNEL INPUT SELECT.
000 = disabled.
001 = uP test register (IWA = 0002h) used as an input, always enabled.
010 = uP test register used as an input, enabled by a strobe at IWA = 0003h.
011 = reserved.
100 = AIN.
101 = BIN.
110 = CIN.
111 = DIN.
FN6006 Rev 3.00
Aug 2004
Page 48 of 71
ISL5416
TABLE 52. CHANNEL PROCESSING CONTROL (IWA = *001h) RESET STATE = 0x00000000h (Continued)
P(31:0)
FUNCTION
16
PN NOISE ENABLE. PN noise is added to the output of the mixer at the level selected in location IWA = *006h. This bit enables the
PN generator to the channel. When 0, IWA = *006h will be a DC offset.
1 = PN added to the mixer output.
0 = PN disabled.
15
CIC FILTER ENABLE.
1 = CIC filter enabled (minimum decimation is 2).
0 = CIC filter disabled (the CIC shifter is used for floating point to fixed point conversion).
14:13
12
11:10
CIC TO FIR1 GAIN ADJUST. The 24-bit output from the NCO/Mixer/CIC Block to FIR1 is scaled and rounded to 20 bits. Saturation
detection is included. This gain stage is always present in the data path.
00 = x1.
01 = x2.
10 = x4.
11 = x8.
FIR1 ENABLE.
1 = FIR1 enabled.
0 = FIR1 bypassed.
FIR1 TO FIR2 GAIN ADJUST. The 24-bit output from the FIR1 Block to FIR2 is scaled and rounded to 20 bits. Saturation detection
is included. This gain stage is always present in the data path.
00 = x1.
01 = x2.
10 = x4.
11 = x8.
9
FIR2 ENABLE.
1 = FIR2 enabled.
0 = FIR2 bypassed.
8
INTERPOLATION HALF BAND FILTER ENABLE.
1 = IHBF enabled.
0 = IHBF bypassed.
7
RESAMPLER ENABLE.
1 = Resampler enabled.
0 = Resampler bypassed.
6
LEAP COUNTER ENABLE.
1 = Resampler leap counter enabled.
0 = Resampler leap counter disabled.
5:3
I/Q OUTPUT ROUNDING. I and Q data busses to the output section are rounded to the selected number of MSBs. Bits below the
programmed number of bits are zeroed.
000 = 24 bits, data on bits 23:0.
001 = 20 bits, data on bits 23:4, bits 3:0 zeroed.
010 = 16 bits, data on bits 23:8, bits 7:0 zeroed.
011 = 12 bits, data on bits 23:12, bits 11:0 zeroed.
100 = 8 bits, data on bits 23:16, bits 15:0 zeroed.
101 = 6 bits, data on bits 23:18, bits 17:0 zeroed.
110 = 4 bits, data on bits 23:20, bits 19:0 zeroed.
111 = reserved.
FN6006 Rev 3.00
Aug 2004
Page 49 of 71
ISL5416
TABLE 52. CHANNEL PROCESSING CONTROL (IWA = *001h) RESET STATE = 0x00000000h (Continued)
P(31:0)
FUNCTION
2:0
AGC GAIN OUTPUT ROUNDING. The AGC gain is rounded to the selected number of bits. The AGC gain word into the rounder is:
E E E E M M M M M M M M M M M M M M.
The AGC gain is 2^E * (1.0 + M / 16384)
EEEE = 0 - 15, MMM...M = 0 - 16383
0 1. M M M M M M M M M M M M M M * 2^(E E E E)
TABLE 54.
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
0
resolution
000
=
E
E
E
E
M
M
M
M
M
M
M
M
M
M
M
M
~
96/65536dB
001
=
E
E
E
E
M
M
M
M
M
M
M
M
Z
Z
Z
Z
~
96/4096dB
010
=
E
E
E
E
M
M
M
M
Z
Z
Z
Z
Z
Z
Z
Z
~
96/256dB
Z = Zero
All other codes are reserved.
TABLE 55. NCO CENTER FREQUENCY (IWA = *002h) RESET STATE = 0x00000000h
P(31:0)
31:0
FUNCTION
CARRIER CENTER FREQUENCY (CCF). The range is -Fs/2 to +Fs/2, where Fs is the input sample rate to the part. The carrier
frequency is: Fc = Fs * CCF / (2^32).
The CCF control is double buffered. The active carrier center frequency register is read at this address.
TABLE 56. NCO PHASE OFFSET (IWA = *003h) RESET STATE = 0x00000000h
P(31:0)
31:16
15:0
FUNCTION
UNUSED.
PHASE OFFSET. This is the value of the phase offset added to the carrier NCO phase. This can be interpreted as either an unsigned
number with a range from 0 to 2 in 65536 steps, or as a signed number with a range of -toin 65536
steps.
TABLE 57. NCO CENTER FREQUENCY UPDATE (IWA = *004h)
RESET STATE = INACTIVE
N/A
FUNCTION
N/A
STROBE. A write to this location generates a one-clock-wide strobe that transfers the carrier center frequency written to the holding
register (IWA = *002h) to the active register. The transfer can also be caused by a SYNCI signal (see IWA = *000h). The contents
of the active register are read at location IWA = *002h.
TABLE 58. NCO/MIXER/CIC CONTROL (IWA = *005h) RESET STATE = 0x00000000h
P(31:0)
FUNCTION
31:29
MAXIMUM EXPONENT SHIFT SATURATION LEVEL. The maximum allowed shift factor from the input A/D range control block and
the exponent from the input bus. If the sum exceeds this value, it will be saturated at this value. This is forced to 111 if the uP test
register is selected as the input source.
28
FORCE ZERO FEEDBACK. Set to 1 to force NCO phase accumulator feedback to 0. (Provided for test)
27
CLEAR FEEDBACK ON UPDATE.
1 = clear NCO phase accumulator on frequency load/update (for synchronizing the NCO phase of multiple channels).
0 = phase continuous frequency updates.
26
RESERVED. Set to 0.
25:20
19
CIC BASE SHIFT FACTOR. The shift factor (exponents) from the input and the range control block are added to this value.
RESERVED. Set to 0.
FN6006 Rev 3.00
Aug 2004
Page 50 of 71
ISL5416
TABLE 58. NCO/MIXER/CIC CONTROL (IWA = *005h) RESET STATE = 0x00000000h
P(31:0)
FUNCTION
18:16
CIC STAGES. Number of CIC integrator/comb pairs (1-5). Stages are enabled starting with the largest accumulator.
000 = 1 stage;
001 = 2 stages;
010 = 3 stages;
011 = 4 stages;
100 = 5 stages;
Load with the number of stages minus 1.
15:0
CIC DECIMATION FACTOR. Load with (decimation - 1).
TABLE 59. PN GAIN (IWA = *006h) RESET STATE = 0x00000000h
P(31:0)
FUNCTION
31:16
UNUSED.
15:0
PN LEVEL. Level of the PN generator data that is added to the mixer output when the PN generator is enabled in IWA = *001h, bit 16.
TABLE 60. FIR1, FIR2, POST-RESAMPLER CONTROL (IWA = *007h) RESET STATE = 0x00000000h
P(31:0)
FUNCTION
31:19
UNUSED.
18:16
DECIMATION OF THE RESAMPLER DECIMATOR BLOCK. Load with the desired decimation factor minus one.
000 = Decimation of 1
111 = Decimation of 8
15
14:12
11
10:8
7
6:4
3
2:0
RESERVED. Set to 0.
FIR2 REQUIRED CLOCKS. This value should be set to: ceil (#TAPS/8) - 1.
RESERVED. Set to 0.
FIR2 DECIMATION. Available decimation through FIR2 block is 1-8. Set the value to: decimation factor - 1.
FIR1 ENABLE HBF MODE.
1 = Half Band Filter mode.
0 = normal mode.
FIR1 REQUIRED CLOCKS. Set to:
ceil (#TAPS/4) - 1.
RESERVED. Set to 0.
FIR1 DECIMATION. Available decimation through FIR1 block is 1-8. Set the value to: decimation factor - 1.
TABLE 61. AGC CONTROL, MEAN/MEDIAN, DELAY, MODE (IWA = *008h) RESET STATE = 0x00000000h
P(31:0)
31:16
FUNCTION
UNUSED.
15
RESERVED. Set to 0.
14
REAL TIME AGC GAIN OUTPUT SOURCE.
0 = the continuously updated loop filter output is provided to the output section as the “real time” AGC gain.
1 = the sampled loop filter output (sampled when the interval count is 0) is provided to the output section as the “real time” AGC gain.
13:8
7
DATA DELAY. This value is the number of samples that data is delayed to allow for AGC settling.
0x00 = no delay.
0x3F = 1 sample
...
0x01 = 63 samples.
LOOP GAIN 1 MEAN/MEDIAN.
1 = AGC settles to mean of the signal if LG1 is selected.
0 = AGC settles to median of the signal.
FN6006 Rev 3.00
Aug 2004
Page 51 of 71
ISL5416
TABLE 61. AGC CONTROL, MEAN/MEDIAN, DELAY, MODE (IWA = *008h) RESET STATE = 0x00000000h (Continued)
P(31:0)
FUNCTION
6
LOOP GAIN 2 MEAN/MEDIAN.
1 = AGC settles to mean of the signal if LG2 is selected.
0 = AGC settles to median of the signal.
5
uP LOOP GAIN SELECT. Set to:
1 = loop gain 2.
0 = loop gain 1.
4
uP LOOP GAIN CONTROL. Set to:
1 = uP loop gain select.
0 = counter controlled loop gain select.
3
DISABLE LOOP FILTER UPDATE. Set to:
1 = disable loop filter (holds the last value, the uP can load).
0 = normal AGC operation.
2
SAMPLED MODE.
1 = continuous forward gain updates.
0 = the forward gain held during the interval count (when loop gain 1 is used). The forward gain is continuously updated after the
interval count (when loop gain 2 is used).
1
ENABLE DELAY. Set to:
1 = enable delay
0 = no delay
NOTE: Delay must be enabled for Sampled Mode.
0
RESERVED. Set to 0.
TABLE 62. CONTROL BIT SETTINGS FOR AGC MODES
AGC MODE
IWA=*001h
IWA = *008h
BIT 20
BIT 4
BIT 2
BIT 1
CONTINUOUS UPDATE
P controls loop gain
0
1
1
0
CONTIUOUS WITH DELAY
0
1
1
1
TIMED LOOP GAIN SELECTION
1
0
1
0
TIMED WITH DELAY
1
0
1
1
SAMPLED GAIN UPDATES
(always with delay)
1
0
0
1
TABLE 63. THRESHOLD (SET POINT) (IWA = *009h) RESET STATE = 0x00000000h
P(31:0)
FUNCTION
31:16
UNUSED.
15:0
SET POINT. Bit weights:
2^
2 1 0. 1 2 3 4 5 6 7 8 9 0 1 2 3, 20 is the full scale vector magnitude on one axis before the magnitude computation gain is applied.
Note: There is a gain in the magnitude computation prior to the threshold compare. The gain versus number of clocks is:
CLOCKS
GAIN
16
1.64676
8
1.647
4
1.642
3
1.630
2
1.581
The set point should be programmed to the desired level times the magnitude gain.
d
FN6006 Rev 3.00
Aug 2004
Page 52 of 71
ISL5416
TABLE 64. UPPER/LOWER GAIN LIMIT (IWA = *00Ah)
P(31:0)
RESET STATE = 0x00000000h
FUNCTION
31:16
UPPER LIMIT.
EEEEMMMMMMMMMMMM
01.MMMMMMMMMMMM * 2^EEEE
Example: A gain of 48 (33.6 dB) would be:
1.5 * 25 or 0101100000000000
15:0
LOWER LIMIT. Same weighting as upper limit.
TABLE 65. LOOP GAINS (1 & 2) (IWA = *00Bh) RESET STATE = 0x00000000h
P(31:0)
FUNCTION
31:24
ATTACK 1. Loop gain value used for increasing signal levels (decreasing gain). Bits 31:28 are the exponent, bits 27:24 are the
mantissa. Loop gain is 0.MMMM * 2EEEE. A loop gain of 00000000 weights the error by 2-19 to the input of the accumulator.
23:16
DECAY 1. Loop gain value used for decreasing signal levels (increasing gain).
15:8
ATTACK 2. Loop gain value used for increasing signal levels (decreasing gain). Bits 15:12 are the exponent, bits 11:8 are the
mantissa. Loop gain is 0.MMMM * 2EEEE. A loop gain of 00000000 weights the error by 2-19 to the input of the accumulator.
7:0
DECAY 2. Loop gain value used for decreasing signal levels (increasing gain).
TABLE 66. AGC COUNTER PRELOADS 1 (IWA = *00Ch) RESET STATE = 0x00000000h
P(31:0)
FUNCTION
31:16
SLOT PERIOD (IN CLOCKS). Sets the timing interval (slot period) counter period. The interval counter can be reset by SYNCInX
(see IWA = *000h) to align it to the system timing. Load with number of clocks minus 1.
15:0
DELAY (In Clocks). Sets the delay from the start of the timing interval (bits (31:16 above) to the start of the interval set in IWA =
*00Dh. Load with number of clocks minus 1.
TABLE 67. AGC COUNTER PRELOADS 2 (IWA = *00Dh) RESET STATE = 0x00000000h
P(31:0)
31:16
15:0
FUNCTION
UNUSED.
ADJUSTMENT INTERVAL (In Clocks). Sets the length of the adjustment period for timed AGC changes. (when loop gain 2 is used
in timed and sampled modes). Load with number of clocks minus 1.
TABLE 68. AGC uP GAIN LOAD VALUE (IWA = *00Eh) RESET STATE = 0x00000000h
P(31:0)
FUNCTION
31:16
UNUSED.
15:0
GAIN. This location allows the uP to set the AGC gain directly. If the gain loaded by the uP is outside the limits set in IWA = *00Ah,
it will be set to the limit value. To set a fixed gain, set the loop gains to zero and the limits to full scale (or set both limits to the desired
gain). Bit weightings are the same as for the limits: EEEE MMMM MMMM MMMM.
TABLE 69. AGC uP GAIN LOAD STROBE (IWA = *00Fh) RESET STATE = INACTIVE
N/A
FUNCTION
N/A
STROBE. Writing to this location generates a strobe, synchronized to the clock, that updates the AGC with the gain value in register
IWA = *00Eh. The transfer can also be caused by a SYNCInX signal (see IWA = *000h).
TABLE 70. READBACK SAMPLE AGC GAIN AND MAGNITUDE (IWA = *010h) RESET STATE = INACTIVE
N/A
FUNCTION
N/A
STROBE. Writing to this location copies the AGC loop filter accumulator contents to a holding register to stabilize it for reading by
the uP at direct addresses 4 - 7. (The magnitude is read at this location after the strobe. Magnitude bit weightings are: 22 . . . 2-13)
FN6006 Rev 3.00
Aug 2004
Page 53 of 71
ISL5416
TABLE 71. NCO 1 OUTPUT RATE -- TOP 32 BITS (IWA = *011h) RESET STATE = 0x00000000h
P(31:0)
FUNCTION
31:0
RSout(48:16). This NCO sets the re-sampler output sample rate when the IHBF/Resampler block is enabled. If the HOIF is bypassed,
this is 2x the AGC (and FIR2) output rate. NOTE that the re-sampler only interpolates. The re-sampler output can be decimated using
a counter. The decimation is programmed in IWA = *007h, bits 18:16.
Fout = Fs * RSout / (2^48), where RSout = 0 to 2^48 -1, Fout = 0 to ~Fs.
Bits 48:16 of the active register are read back at this location.
If HOIF is enabled, then Fout must be FCLK/2
If IHBF is enabled, HOIF disabled, then Fout must be FCLK
TABLE 72. NCO 1 OUTPUT RATE -- LOWER 16 BITS (IWA = *012h) RESET STATE = 0x00000000h
P(31:0)
FUNCTION
31:16
RSout(15:0). See IWA = *011h. Bits 15:0 of the active register are read back at this location.
15:0
UNUSED.
TABLE 73. NCO 2 INPUT RATE -- TOP 32 BITS (IWA = *013h)
P(31:0)
31:0
RESET STATE = 0x00000000h
FUNCTION
RSin(48:16). This NCO sets the output sample rate for the FIFO (input sample rate to the IHBF/Resampler block) when the
IHBF/Resampler block is enabled. If the HOIF is bypassed, this has no effect.
Fin = Fout * RSin / (2^48), where RSin = 0 to 2^48 -1, Fin = 0 to ~Fout.
Fin should be set equal to the output sample rate of FIR2 (Fs / (CICdeci * FIR1deci * FIR2deci)).
Bits 48:16 of the active register are read back at this location.
TABLE 74. NCO 2 INPUT RATE -- LOWER 16 BITS (IWA = *014h)
P(31:0)
RESET STATE = 0x00000000h
FUNCTION
31:16
RSin(15:0). See IWA = *013.
Bits 15:0 of the active register are read back at this location.
15:0
UNUSED.
Register IWA = *015h is used to add delay to a channel. The output timing is unaffected (except at startup from reset). but the
group delay of the channel is adjusted. If the IHBF and HOIF are both enabled, the total delay range is 0 to 1023/256 FIR2 output
sample periods. NOTE: The HOIF can be enabled with no rate change by setting the NCO2 register (IWA = *013h and *014h) to
zero and setting the bit 22 of IWA = *001h.
TABLE 75. PHASE OFFSET (IWA = *015h) RESET STATE = 0x00000000h
P(31:0)
FUNCTION
31:11
RESERVED. Set to 0.
10:9
FIFO DEPTH. After reset, the FIFO waits until it reaches a depth of 2 + this value (total of 2, 3, 4, or 5) before allowing FIFO reads.
These bits can be used to add delay in increments of the FIR2 output sample rate.
HOIF or IHBF must be enabled.
8
7:0
HOIF INPUT DELAY.
1 = one HOIF input sample delay is added.
HOIF must be enabled.
RESAMPLER PHASE OFFSET. Allows the output sample timing to be shifted in increments of 1/256 the HOIF input period.
00 = least delay.
FF = most delay.
HOIF must be enabled.
FN6006 Rev 3.00
Aug 2004
Page 54 of 71
ISL5416
TABLE 76. LEAP COUNTER (IWA = *016h) RESET STATE = 0x00000000h
P(31:0)
FUNCTION
31:0
LEAP COUNTER PRELOAD.
When the leap counter reaches zero, it resets the phase accumulators in NCO1 and NCO2 to zero (if enabled). Because some
frequencies cannot be represented exactly by the NCO control word, this function is provided to zero out any error that builds up due
to the limited NCO resolution. Load with the desired number of clocks between resets minus 1. Note that the ceiling function should
be used when computing the NCO frequency control words so that the NCOs build up a positive phase error and phase accumulator
carries are not suppressed.
TABLE 77. RESAMPLER FREQUENCY/PHASE UPDATE STROBE (IWA = *017h) RESET STATE = INACTIVE
N/A
N/A
FUNCTION
STROBE. A write to this location transfers the contents of IWA = *011/*012h and IWA = *013/*014h holding registers to the active
resampler NCO frequency registers. The transfer can also be caused by a SYNCInX signal (see IWA = *000h).
TABLE 78. CHANNEL SOFT RESET (IWA = *018h) RESET STATE = INACTIVE
N/A
FUNCTION
N/A
SOFT RESET. A write to this location generates a soft reset of the channel. This clears the slave registers of master/slave pairs and
stops processing in the channel.
TABLE 79. UPDATE DATA PATH CONTROL REGISTER (IWA = *019h) RESET STATE = INACTIVE
N/A
FUNCTION
N/A
STROBE. A write to this location updates the active data path control register from its holding register. The transfer can also be
caused by a SYNCInX signal (see IWA = *000h). The active register is cleared on reset, disabling channel processing, so this update
is used to synchronously start the channel processing.
TABLE 80. ADVANCE (IWA = *01Ah) RESET STATE = INACTIVE
N/A
FUNCTION
N/A
STROBE. A write to this location repeats one sample at the output of the CIC. Should only be used if there is sufficient overhead for
processing an extra sample.
Locations IWA = *01A and *01B delete or repeat a sample at
the input to FIR1 to shift the system timing. These locations
should not be used if the IHBF or re-sampler is enabled.
TABLE 81. RETARD (IWA = *01Bh) RESET STATE = INACTIVE
N/A
N/A
FUNCTION
STROBE. A write to this location deletes one sample at the output of the CIC.
TABLE 82. FIR 1 COEFFICIENTS (32 x 20) (IWA = *100h THRU *11Fh) RESET STATE = INACTIVE
P(31:0)
FUNCTION
31:20
UNUSED.
19:0
COEFFICIENTS. Twos complement -524287 to +524287 (-524288 not allowed). +524288 would be unity gain.
TABLE 83. FIR 2 COEFFICIENTS (64 x 20) (IWA = *200h THRU *23Fh) RESET STATE = UNDEFINED
P(31:0)
FUNCTION
31:20
UNUSED.
19:0
COEFFICIENTS. Twos complement -524287 to +524287 (-524288 not allowed). +524288 would be unity gain.
FN6006 Rev 3.00
Aug 2004
Page 55 of 71
ISL5416
TABLE 83. FIR 2 COEFFICIENTS (64 x 20) (IWA = *200h THRU *23Fh) RESET STATE = UNDEFINED
P(31:0)
FUNCTION
Each multiplier has up to 8 coefficients. If the six bit coefficient addresses are labeled M2 M1 M0 C2 C1 C0, where the M-bits
select the multiplier (000 is the first multiplier encountered by the data samples), and the C-bits select the coefficient (000 is the
first coefficient encountered by the data samples). M2 is not used for FIR1.
For example, if an eight tap filter is used for FIR1, the coefficients would be loaded:
(earliest)
C0 --- 000000 (*100h)
C1 --- 000001
C2 --- 001000
C3 --- 001001
C4 --- 010000
C5 --- 010001
C6 --- 011000
C7 --- 011010 (*11Ah)
When the Half Band Filter mode is enabled for FIR1, the zero valued zero crossing coefficients are not loaded, but the
coefficients must be centered around the hard wired center tap. This means that zeros valued coefficients must be added if the
number of coefficients per multiplier is not uniform. For example, with an 11-tap Half Band Filter with coefficients:
C0, 0, C1, 0, C2, 0.5, C3, 0, C4, 0, C5,
the coefficient loading would be:
0 ----- 000000 (*100h)
C0 --- 000001
C1 --- 001000
C2 --- 001001
C3 --- 010000
C4 --- 010001
C5 --- 011000
0 ----- 011001 (*119h)
The filter computation requires two clock cycles for the computation. Due to the added zero-valued coefficients, the group delay
has increased from 6 to 8 sample periods.
FN6006 Rev 3.00
Aug 2004
Page 56 of 71
ISL5416
Absolute Maximum Ratings
Thermal Information
Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5 (core)
4.6 (I/O’s)
Input, Output or I/O Voltage . . . . . . . . . . . . . . . . . GND -0.5V to 5.5V
ESD Classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Class I
Thermal Resistance (Typical)
Operating Conditions
Voltage Range I/O, VCCIO . . . . . . . . . . . . . . . . . +3.135V to +3.465V
Voltage Range core, VCCC . . . . . . . . . . . . . . . . . . +1.71V to +1.89V
Temperature Range
Industrial. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -40oC to 85oC
Input Low Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0V to +0.8V
Input High Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . 2V to I/O VCCIO
JA (oC/W)
256 Lead BGA Package. . . . . . . . . . . . . . . . . . . . . .
31
w/200 LFM Air Flow . . . . . . . . . . . . . . . . . . . . . . . . .
28
w/400 LFM Air Flow . . . . . . . . . . . . . . . . . . . . . . . . .
26
Maximum Junction Temperature . . . . . . . . . . . . . . . . . . . . . . .150oC
Maximum Storage Temperature Range . . . . . . . . . . -65oC to 150oC
For recommended soldering conditions see Tech Brief 334.
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of the
device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
NOTE: NOTEJA is measured with the component mounted on a high effective thermal conductivity test board with “direct attach” features in free
air or with the airflow. See Tech Brief TB379 for details
Electrical Specifications
PARAMETER
VCCC = Core supply: 1.8V0.09V, TA = -40oC to 85oC, Industrial
SYMBOL
TEST CONDITIONS
Logical One Input Voltage
VIH
VCCIO = 3.45V
Logical Zero Input Voltage
VIL
VCCIO = 3.15V
Output High Voltage
VOH
IOH = -2mA, VCCC = 3.15V
Output Low Voltage
VOL
IOL = 2mA, VCCC = 3.15V
MIN
TYPICAL
MAX
2.0
V
0.8
2.6
Input Leakage Current
II
VIN = VCCIO or GND, VCCIO = 3.465V
-10
Output Leakage Current
IO
VIN = VCCIO or GND, VCCIO = 3.465V
-10
UNITS
3
V
V
0.1
0.4
V
<1
(NOTE 3)
10
A
10
A
12
(NOTE 6)
mA
Standby Power Supply Current
(core)
ICCSB-CR
VCCC = 1.89V, See AC Test load circuit, No
CLK
Standby Power Supply Current
(IO’s)
ICCSB-IO
VCCC = 1.89V, See AC Test load circuit,
No CLK
0.75
mA
Operating Power Supply Current
(core)
ICCOP-CR
f = 80MHz, VIN = VCCC or GND,
VCCC= 1.89V, See AC Test load circuit,
660
mA
Operating Power Supply Current
(IO’s)
ICCOP-IO
f = 80MHz, VIN = VCCC or GND,
VCCC = 1.89V, See AC Test load circuit,
150
mA
ICCOP-TYP
f = 80MHz, VIN = VCCC or GND,
VCCC = 1.89V, See AC Test load circuit,
Operating Power Supply Core
Current (typical)
Input Capacitance
Output Capacitance
CIN
Freq = 1MHz, VCCC open, all measurements
are referenced to device ground
COUT
500
(NOTE 1, 4)
mA
5
pF
(Note 2)
5
pF
(Note 2)
NOTES:
1. Power Supply current is proportional to frequency of operation and programmed configuration of the part. Typical rating for ICCOP is 6.5 mA/MHz.
2. Capacitance: TA = 25oC, controlled via design or process parameters and not directly tested. Characterized upon initial design and at major
process or design changes.
3. Typical Pull-up/down resistance values are 60 k.
4. Typical measured power on the Evaluation board:
•. UMTS: CLK = 76.8 MHz, Total Power = 1.1 W (core current = 500 mA; I/O current = 60 mA)
•. CDMA2000: CLK = 80 MHz, Total Power = 750 mW (core current = 360 mA; I/O current = 30 mA).
FN6006 Rev 3.00
Aug 2004
Page 57 of 71
ISL5416
Electrical Specifications
o
o
VCCC = Core supply: 1.8V0.09V, VCCIO = IO’s supply: 3.3V0.165V, TA = -40 C to 85 C Industrial
PARAMETER
SYMBOL
MIN
MAX
UNITS
CLKC Frequency
fCLK
-
95
MHz
CLKC High
tCH
3
-
ns
CLKC Low
tCL
4
-
ns
Setup Time - Data Inputs, Input Enables to CLKX High
tDS
5.5
-
ns
Hold Time - Data Inputs, Input Enables to CLKX High
tDH
0
-
ns
Setup Time - SYNCInX to CLKC High
tSYNCS
3
Hold Time - SYNCInX to CLKC High
tSYNCH
0
INPUT AND CONTROL TIMING, CLOCK SKEW (FIGURE 11 AND 12)
CLKC to Output Valid - SYNCO
tPDC
-
5
ns
RESET Pulse Width Low
tRW
5
-
ns
RESET Setup Time to CLKC High (Note 5)
tRS
5
-
ns
CLKX to CLKC skew 1 (FIGURE 12)
tCKS1
2.5
CLKX to CLKC skew 2 (FIGURE 12)
tCKS2
2.5
P(15:0) Setup Time to Rising Edge of WR
tPSW
7.5
-
ns
P(15:0) Hold Time from Rising Edge of WR
tPHW
-1
-
ns
MICROPROCESSOR WRITE TIMING (P mode = 0, FIGURE 13)
A(2:0) Setup Time to Rising Edge of WR
tASW
8.5
-
ns
A(2:0) Hold Time from Rising Edge of WR
tAHW
-2
-
ns
CE Setup Time to Rising Edge of WR
tCSW
7
-
ns
CE Hold Time from Rising Edge of WR
tCHW
-2
-
ns
tWPWL
5
-
ns
tAHR
-4
-
ns
tDV
-
19
ns
RD Enable Time
tRE
-
8.5
ns
RD Disable Time (Note 6)
tRD
-
6
ns
CE Setup Time to Falling Edge of RD
tCSF
2.5
-
ns
CE Hold Time from Rising Edge of RD (Note 6)
tCHR
0
-
ns
READ Cycle Time (Note 7)
tRCY
25
-
ns
P(15:0) Setup Time to Rising Edge of DSTRB
tPSR
8
-
ns
P(15:0) Hold Time from Rising Edge of DSTRB
tPHR
-0.5
-
ns
WR Low Time
MICROPROCESSOR READ TIMING (P mode = 0, FIGURE 14)
A(2:0) Hold Time from RISING Edge of RD (Note 7)
A(2:0) to P(15:0) Data Valid Time
MICROPROCESSOR WRITE TIMING (P MODE = 1, FIGURE 15)
A(2:0) Setup Time to Rising Edge of DSTRB
tASR
7.5
-
ns
A(2:0) Hold Time from Rising Edge of DSTRB
tAHR
-1.5
-
ns
CE Setup Time to Rising Edge of DSTRB
tCSR
8
-
ns
CE Hold Time from Rising Edge of DSTRB
tCHR
-2
-
ns
R/W Setup Time to Falling Edge of DSTRB
tR/WSF
0
-
ns
R/W Hold Time from Rising Edge of DSTRB
tR/WHR
-1
-
ns
tDW
6
-
ns
tAHR
-1
-
ns
tDV
-
16
ns
DSTRB Low Time
MICROPROCESSOR READ TIMING (P MODE = 1, FIGURE 16)
A(2:0) Hold Time from RISING Edge of DSTRB (Note 7)
A(2:0) to P(15:0) Data Valid Time
FN6006 Rev 3.00
Aug 2004
Page 58 of 71
ISL5416
Electrical Specifications
o
o
VCCC = Core supply: 1.8V0.09V, VCCIO = IO’s supply: 3.3V0.165V, TA = -40 C to 85 C Industrial
PARAMETER
SYMBOL
MIN
MAX
UNITS
DSTRB Enable Time
tRE
DSTRB Disable Time (Note 6)
tRD
-
14
ns
-
6.5
ns
CE Setup Time to Falling Edge of DSTRB
tCSF
7.5
-
ns
CE Hold Time from Rising Edge of DSTRB (Note 7)
tCHR
-2
-
ns
-
DSTRB Low Time
tDW
5
READ Cycle Time (Note 8)
tRCY
25
ns
ns
TSTT
4.5
ns
THTT
1.5
JTAG TIMING (FIGURE 17)
TDI, TMS Set Up
TDI, TMS Hold
ns
TCLK TO TDO VALID
TOVTDO
7
ns
TCLK TO TDO DISABLED
TODTDO
7
ns
TCLK TO TDO ENABLED
TOETDO
7
ns
CAPTURE INPUT SETUP TIME
tISTP
5
ns
CAPTURE INPUT HOLD TIME
tIHLD
1.5
ns
TCLK TO OUTPUT VALID (Note 6)
tDVLD
2
6
ns
CLKC to Parallel Data, FSYNCX and CLKO1 (Divide-by 2 thru 16 Modes)
tPD
2
(NOTE 6)
6.5
ns
CLKC Low to CLKO1 Low (Divide-by 1 Mode)
tPDL
2
(NOTE 6)
6.5
ns
CLKC High to CLKO1 High (Divide-by 1 Mode)
tPDH
2
(NOTE 6)
6.5
ns
Time Skew Between CLKO1 and Parallel Data or FSYNCX (Divide-by 2 thru 16 Modes)
tSKEW3
-1.5
1.5
ns
Time Skew Between CLKO1 and Parallel Data or FSYNCX (Divide-by 1 Mode)
tSKEW4
-2.5
1.5
ns
CLOCK OUTPUT TIMING AND OUTPUT ENABLES (FIGURE 18)
OUTPUT ENABLE TIME
tOEN
6
ns
OUTPUT DISABLE TIME
tODIS
4
ns
NOTES:
5. The ISL5416 goes into reset immediately on RESET going low and comes out of reset on the 4th rising edge of CLK after RESET goes high.
6. Controlled via design or process parameters and not directly tested. Characterized upon initial design and at major process or design changes.
7. tAHR and tCHR apply ONLY to direct reads of addresses 4 - 7.
8. Reading from direct addresses 4 - 7 (Sequential Read Mode).
AC Test Load Circuit
S1
DUT
CL (NOTE)
NOTE - TEST HEAD CAPACITANCE, 50pF (TYP)
SWITCH S1 OPEN FOR ICCSB AND ICCOP
FN6006 Rev 3.00
Aug 2004
IOH

1.5V
IOL
EQUIVALENT CIRCUIT
Page 59 of 71
ISL5416
Waveforms
1/fCLKC
tCH
tCL
CLKC
tDS
tDH
Xin, ENIX
tPDC
XOUT, SYNCO
tRW
tRS
RESET
tSYNCH
tSYNCS
SYNCInX
X = A, B, C or D
LOW to HIGH edge for active HIGH clock
HIGH to LOW edge for active LOW clock
FIGURE 11. CONTROL TIMING
CLKX
tCKS2
tCKS1
CLKC
X = A, B, C or D
FIGURE 12. CLOCK SKEWS
FN6006 Rev 3.00
Aug 2004
Page 60 of 71
ISL5416
Waveforms
(Continued)
RD
tWPWL
WR
tCSW
tCHW
CS
tASW
tAHW
VALID
A<2:0>
tPSW
tPHW
VALID
P<15:0>
FIGURE 13. MICROPROCESSOR WRITE TIMING (P mode = 0)
tRCY
RD
CE
WR
ADD(2:0)
P(15:0)
tRE
tDV
tRD
tAHR
tCSF
tCHR
FIGURE 14. MICROPROCESSOR READ TIMING (P mode = 0)
FN6006 Rev 3.00
Aug 2004
Page 61 of 71
ISL5416
Waveforms
(Continued)
CE
RD/WR
ADD(2:0)
P(15:0)
DSTRB
tDW
tR/WSF
tPSR
tCSR
tASR
tPHR
tAHR
tCHR
tR/WHR
FIGURE 15. MICROPROCESSOR WRITE TIMING (P mode = 1))
CE
RD/WR
ADD(2:0)
P(15:0)
tRCY
DSTRB
tRE
tDV
tCSF
tRWSF
tRD
tDW
tAHR
tCHR
FIGURE 16. MICROPROCESSOR READ TIMING (P mode = 1))
FN6006 Rev 3.00
Aug 2004
Page 62 of 71
ISL5416
Waveforms
(Continued)
tISTP
tIHLD
INPUTS
(CAPTURE)
TCLK
TSTT
THTT
TDI, TMS
TDO
TOVTDO
TODTDO
TOETDO
OUTPUTS
tDVLD
FIGURE 17. JTAG TIMING
FN6006 Rev 3.00
Aug 2004
Page 63 of 71
ISL5416
Waveforms
(Continued)
CLKC
CLKO1
(/2 THRU /16)
CLKO1
(DIVIDE BY 1)
tPDH
tPDL
tSKEW3
FSYNCX
tSKEW4
AOUT, BOUT, COUT, DOUT,
EOUT
tPD
OEX
tODIS
tOEN
XOUT
FIGURE 18. OUTPUT TIMING
FN6006 Rev 3.00
Aug 2004
Page 64 of 71
ISL5416
TABLE 84. CIC PASSBAND AND ALIAS LEVELS
FREQUENCY
5TH ORDER
4TH ORDER
3RD ORDER
2ND ORDER
1ST ORDER
fS / R
PASSBAND
ALIAS
PASSBAND
ALIAS
PASSBAND
ALIAS
PASSBAND
ALIAS
PASSBAND
0
0
<-200
0
<-200
0
<-200
0
<-200
0
ALIAS
<-200
0.01
-0.007
-199.564
-0.006
-159.651
-0.004
-119.738
-0.003
-79.825
-0.001
-39.913
0.02
-0.029
-169.041
-0.023
-135.233
-0.017
-101.425
-0.011
-67.617
-0.006
-33.808
0.03
-0.064
-151.023
-0.051
-120.818
-0.039
-90.614
-0.026
-60.409
-0.013
-30.205
0.04
-0.114
-138.129
-0.091
-110.503
-0.069
-82.877
-0.046
-55.252
-0.023
-27.626
0.05
-0.179
-128.048
-0.143
-102.438
-0.107
-76.829
-0.071
-51.219
-0.036
-25.610
0.06
-0.257
-119.749
-0.206
-95.799
-0.154
-71.849
-0.103
-47.900
-0.051
-23.950
0.07
-0.351
-112.683
-0.280
-90.146
-0.210
-67.610
-0.140
-45.073
-0.070
-22.537
0.08
-0.458
-106.522
-0.367
-85.218
-0.275
-63.913
-0.183
-42.609
-0.092
-21.304
0.09
-0.580
-101.054
-0.464
-80.843
-0.348
-60.633
-0.232
-40.422
-0.116
-20.211
0.10
-0.717
-96.135
-0.573
-76.908
-0.430
-57.681
-0.287
-38.454
-0.143
-19.227
0.11
-0.868
-91.662
-0.694
-73.330
-0.521
-54.997
-0.347
-36.665
-0.174
-18.332
0.12
-1.034
-87.558
-0.827
-70.047
-0.620
-52.535
-0.413
-35.023
-0.207
-17.512
0.13
-1.214
-83.766
-0.971
-67.013
-0.728
-50.260
-0.486
-33.507
-0.243
-16.753
0.14
-1.409
-80.241
-1.127
-64.193
-0.846
-48.145
-0.564
-32.096
-0.282
-16.048
0.15
-1.619
-76.947
-1.295
-61.558
-0.972
-46.168
-0.648
-30.779
-0.324
-15.389
0.16
-1.844
-73.855
-1.475
-59.084
-1.107
-44.313
-0.738
-29.542
-0.369
-14.771
0.17
-2.084
-70.943
-1.667
-56.754
-1.251
-42.566
-0.834
-28.377
-0.417
-14.189
0.18
-2.340
-68.189
-1.872
-54.551
-1.404
-40.913
-0.936
-27.276
-0.468
-13.638
0.19
-2.610
-65.579
-2.088
-52.463
-1.566
-39.347
-1.044
-26.231
-0.522
-13.116
0.20
-2.896
-63.098
-2.317
-50.478
-1.737
-37.859
-1.158
-25.239
-0.579
-12.620
0.21
-3.197
-60.734
-2.558
-48.587
-1.918
-36.440
-1.279
-24.294
-0.639
-12.147
0.22
-3.514
-58.477
-2.811
-46.782
-2.108
-35.086
-1.406
-23.391
-0.703
-11.695
0.23
-3.847
-56.319
-3.077
-45.055
-2.308
-33.792
-1.539
-22.528
-0.769
-11.264
0.24
-4.195
-54.252
-3.356
-43.402
-2.517
-32.551
-1.678
-21.701
-0.839
-10.850
0.25
-4.560
-52.269
-3.648
-41.815
-2.736
-31.361
-1.824
-20.907
-0.912
-10.454
0.26
-4.941
-50.363
-3.953
-40.291
-2.965
-30.218
-1.976
-20.145
-0.988
-10.073
0.27
-5.338
-48.531
-4.271
-38.825
-3.203
-29.119
-2.135
-19.412
-1.068
-9.706
0.28
-5.752
-46.767
-4.602
-37.413
-3.451
-28.060
-2.301
-18.707
-1.150
-9.353
0.29
-6.183
-45.066
-4.946
-36.053
-3.710
-27.040
-2.473
-18.026
-1.237
-9.013
0.30
-6.631
-43.426
-5.305
-34.740
-3.978
-26.055
-2.652
-17.370
-1.326
-8.685
0.31
-7.096
-41.842
-5.677
-33.473
-4.257
-25.105
-2.838
-16.737
-1.419
-8.368
0.32
-7.578
-40.311
-6.063
-32.249
-4.547
-24.187
-3.031
-16.125
-1.516
-8.062
0.33
-8.078
-38.832
-6.463
-31.066
-4.847
-23.299
-3.231
-15.533
-1.616
-7.766
0.34
-8.596
-37.401
-6.877
-29.921
-5.158
-22.440
-3.439
-14.960
-1.719
-7.480
0.35
-9.133
-36.015
-7.306
-28.812
-5.480
-21.609
-3.653
-14.406
-1.827
-7.203
0.36
-9.688
-34.674
-7.750
-27.739
-5.813
-20.804
-3.875
-13.869
-1.938
-6.935
0.37
-10.262
-33.374
-8.209
-26.699
-6.157
-20.024
-4.105
-13.349
-2.052
-6.675
0.38
-10.854
-32.114
-8.684
-25.691
-6.513
-19.268
-4.342
-12.845
-2.171
-6.423
0.39
-11.467
-30.892
-9.174
-24.713
-6.880
-18.535
-4.587
-12.357
-2.293
-6.178
0.40
-12.099
-29.707
-9.679
-23.766
-7.260
-17.824
-4.840
-11.883
-2.420
-5.941
0.41
-12.752
-28.557
-10.201
-22.846
-7.651
-17.134
-5.101
-11.423
-2.550
-5.711
0.42
-13.425
-27.442
-10.740
-21.953
-8.055
-16.465
-5.370
-10.977
-2.685
-5.488
0.43
-14.119
-26.359
-11.295
-21.087
-8.472
-15.815
-5.648
-10.544
-2.824
-5.272
0.44
-14.835
-25.308
-11.868
-20.246
-8.901
-15.185
-5.934
-10.123
-2.967
-5.062
0.45
-15.573
-24.287
-12.458
-19.430
-9.344
-14.572
-6.229
-9.715
-3.115
-4.857
0.46
-16.333
-23.296
-13.066
-18.637
-9.800
-13.978
-6.533
-9.318
-3.267
-4.659
0.47
-17.116
-22.334
-13.693
-17.867
-10.270
-13.400
-6.847
-8.933
-3.423
-4.467
0.48
-17.923
-21.399
-14.339
-17.119
-10.754
-12.840
-7.169
-8.560
-3.585
-4.280
0.49
-18.754
-20.492
-15.003
-16.393
-11.253
-12.295
-7.502
-8.197
-3.751
-4.098
0.50
-19.610
-19.610
-15.688
-15.688
-11.766
-11.766
-7.844
-7.844
-3.922
-3.922
FN6006 Rev 3.00
Aug 2004
Page 65 of 71
ISL5416
TABLE 85. ISL5416 RANGE CONTROL BIT WEIGHTING
G
0.
1
2
3
4
5
6
7
8
9
A
B
C D
E
F
INPUT
S
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
DC OFFSET
S
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
MAGNITUDE
0
F
0
E
0
D C
0
0
B
0
A
0
9
0
8
0
7
0
6
0
5
0
4
0
3
0
2
0
1
0
IMMEDIATE
THRESHOLD
ACCUMULATOR
0
X
X
X
X
X
X
X
X
X
X
X
X
X
X
SHIFT:
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
0
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

SHIFTER OUTPUT
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
THRESHOLD 1,
THRESHOLD 2
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
dB VALUE
24 12 6
GAIN
ACCUMULATOR
0
X
X
uP DELTA
PROGRAMMED
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
(14 bits)
Max Delta = 12 dB
DELTA3 (LOWER)
1
1
1
X
X
X
X
X
X
X
X
X
X
X
X
X
X
(accumulator + DELTA 1)
DELTA 2 (UPPER)
0
0
0
X
X
X
X
X
X
X
X
X
X
X
X
X
X
(accumulator + DELTA 2)
DELTA 1 (IMMED.)
0
0
0
X
X
X
X
X
X
X
X
X
X
X
X
X
X
(accumulator + DELTA 3)
uP LOAD BITS
0
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
S
S
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
LEAK
(accumulator + leak)
MSB is sign extended
LIMITS
0
TO MAPPING LUT
X
X
X
X
X
X
TABLE 86. AGC BIT WEIGHTS
AGC BIT
WEIGHTS
F E D C B A 9 8 7 6 5 4 3 2 1 0. 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
FORWARD
GAIN PATH
INPUTS I/Q
FN6006 Rev 3.00
Aug 2004
S. 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3
Page 66 of 71
ISL5416
TABLE 86. AGC BIT WEIGHTS (Continued)
AGC BIT
WEIGHTS
F E D C B A 9 8 7 6 5 4 3 2 1 0. 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
BARREL SHIFTER SHIFT
EEEE = 0
S. 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3
EEEE = 4
S. 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 G G G G
EEEE = 8
S. 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 G G G G G G G G
EEEE = 15
S. 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 G G G G G G G G G G G G G G G
------------SATURATE ON OVERFLOW----------
BS OUT /
MULT IN
MULT
1.0 <= M<= 2.0
MULT OUT
S. 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3
G V 1 2 3 4 5 6 7 8 9 0 1 2 3 4
S 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3
SATURATE BASED ON SHIFT AND MULT OUT:
FEEDBACK
PATH;
OUTPUTS I/Q
S. 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3
MAG IN
S. 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3
MAGNITUDE (G = 1.647, MAX IN = 1.414, MAX OUT = 2.33):
G 1 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3
THRESHOLD
2 1 0 1 2 3 4 5 6 7 8 9 0 1 2 3
MEAN ERROR
S 1 0 1 2 3 4 5 6 7 8 9 0 1 2 3
MEDIAN
ERROR
G G G. V G G G G G G G G G G G G
LG MANTISSA
LG MANT
MULT OUT
V V V. V G G G G G G G G G G G G
G. 1 2 3 4
S 1 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5
LG EXP SHIFT
=0
S S S S S S S S S S S S S S S S S 1 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4
LG EXP SHIFT
=4
S S S S S S S S S S S S S 1 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 G G G
LG EXP SHIFT
=8
S S S S S S S S S 1 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 G G G G G G G
LG EXP SHIFT
= 15
S S 1 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 G G G G G G G G G G G G G G
LG ACCUM
3 2 1 0. 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
LL / UL
G G G 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5
OUTPUT FWD
GAIN
OUTPUT uP /
PARALLEL
E E E E M M M M M M M M M M M M M M
G E E E E M M M M M M M M M M M
BIT WEIGHTS (dB); MAX GAIN = 96.3293 dB
4 2 1
8 4 2 6 3 1 0 0 0 0 0 0 0 0 0 0 0 0
S = SIGN
.
G = LOGIC 0
1 0 0 0 0 5 7 3 1 0 0 0 0 0 0 0 0 0
E=EXPONENT
6 8 4 2 1 0 5 7 8 9 4 2 1 0 0 0 0 0
M=
MANTISSA
4 2 1 0 0 5 2 6 8 4 7 3 1 5 2 1 0 0
V = LOGIC 1
8 4 2 6 3 1 5 3 1 1 0 5 7 9 9 5 7 4
FN6006 Rev 3.00
Aug 2004
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Page 67 of 71
ISL5416
0.0
0
-1.0
-20
-40
-2.0
dB
N=1
-60
-3.0
N=2
-4.0
-80
N=5
-100
N=3
-5.0
N=4
-6.0
0.0
0.1
0.2
-120
0.3
0.4
0.5
fS/R
FIGURE 19. CIC PASSBAND ROLLOFF (N = # OF STAGES,
R = DECIMATION FACTOR, fS/R = 1 is CIC
OUTPUT RATE)
-140
-160
-180
0
-20
1
2
3
4
5
6
4
0
x 10
FIGURE 20. A TYPICAL CARRIER NCO SPECTRUM
PLOT (65536 POINT FFT, BLACKMAN WINDOW,
800 Hz BIN NBW (29 dB). PEAK BIN IS AT -132
dBc, NOISE FLOOR AT -190 dBc/Hz.
N=1
-40
dB
-60
-80
N=2
N=3
-100
N=4
-120
N=5
-140
0.00
0.10
0.20
0.30
0.40
0.50
fS/R
FIGURE 19A. CIC FIRST ALIAS LEVEL (N = # OF STAGES,
R = DECIMATION FACTOR, fS/R = 1 is CIC
OUTPUT RATE)
0
-20
-40
dB
-60
-80
-100
-120
-140
0.0
0.5
1.0
1.5
2.0
2.5
3.0
fS/R
FIGURE 19B. 5TH ORDER (N = 5) CIC RESPONSE
(R = DECIMATION FACTOR, fS/R = 1 is CIC
FN6006 Rev 3.00
Aug 2004
Page 68 of 71
ISL5416
Data Sheet Revisions:
TABLE 87. REVISION HISTORY
REVISION
6006.2
DATE
DESCRIPTION
January 10, 2003
- TRST Pin Description text added for Circuit Board schematics
- Added text in the VGA/RF Attenuator (Range Control) section, last paragraph
- Figure 3, “NCO, Mixer and CIC Block Diagram”, corrected FIR coefficients table
- Figure 4, “FIR1 and FIR2 Block Diagrams”, updated
- Added Power-up Sequencing Explanation on Page 27
- Table 24, IWA = 0*01h, updated register description (bit values remained the same)
- Table 51, IWA = *000h, updated register description (bit values remained the same)
- Table 52, IWA = *001h, bits 31:29, updated description (bit values remained the same)
- Table 52, IWA = *001h, bits 2:0, updated description (bit values remained the same)
- Table 61, IWA = *008h, bit 0 changed to “RESERVED, Set to 0”
- Table 62, “Control Bit Settings for AGC Modes” added
- Table 83, Added the FIR coefficient loading procedure at the bottom of the table
- In Electrical Specifications table added the following values: tCHR, tRCY, tDW
- Figure 12, “Clock Skews”, updated
- Added package drawing note (last page)
CDMA2000-1XRTT:
Figure below shows the overall response using 5-stage CIC filter,
32-tap first FIR filter block and 64-tap second FIR filter block.
-20
-40
-60
-80
-1 00
-1 20
1
2
3
4
5
6
7
8
9
10
x 10
6
FIGURE 21. OVERALL FILTER RESPONSE OF A SINGLE CDMA2000 CHANNEL
FN6006 Rev 3.00
Aug 2004
Page 69 of 71
ISL5416
UMTS / W-CDMA:
Figure below shows the overall response using 5-stage CIC
filter, 32-tap first FIR filter block and 64-tap second FIR filter
block.
0
-20
-40
-60
-80
-100
0.5
1
1.5
2
2.5
3
x 10
7
FIGURE 22. OVERALL FILTER RESPONSE OF A SINGLE UMTS CHANNEL
FN6006 Rev 3.00
Aug 2004
Page 70 of 71
ISL5416
Plastic Ball Grid Array Packages (BGA)
o
A1
CORNER
V256.17x17
A
D
256 BALL PLASTIC BALL GRID ARRAY PACKAGE
A1
CORNER I.D.
INCHES
SYMBOL
E
B
TOP VIEW
0.15
MC A B
0.006
0.08
C
0.003 M
b
A1
CORNER
D1
A1
CORNER I.D.
16 15 14 13 1211 10 9 8 7 6 5 4 3 2 1
A
B
C
D
E
F
G
H E1
J
K
L
M
N
P
R
T
S
A
A
MILLIMETERS
MIN
MAX
NOTES
A
-
0.059
-
1.50
-
A1
0.012
0.016
0.31
0.41
-
A2
0.037
0.044
0.95
1.13
-
b
0.016
0.020
0.41
0.51
7
D/E
0.665
0.673
16.90
17.10
-
D1/E1
0.587
0.595
14.90
15.10
-
N
256
256
-
e
0.039 BSC
1.0 BSC
-
MD/ME
16 x 16
16 x 16
-
bbb
0.004
0.10
3

0.005
0.12
Rev. 2 01/03
1. Controlling dimension: MILLIMETER. Converted inch
dimensions are not necessarily exact.
2. Dimensioning and tolerancing conform to AMSE Y14.5M-1994.
3. “MD” and “ME” are the maximum ball matrix size for the “D” and
“E” dimensions, respectively.
4. “N” is the maximum number of balls for the specific array size.
5. Primary datum C and seating plane are defined by the spherical
crowns of the contact balls.
ALL ROWS AND COLUMNS
BOTTOM VIEW
A1
A2
MAX
NOTES:
e
S
MIN
6. Dimension “A” includes standoff height “A1”, package body thickness and lid or cap height “A2”.
7. Dimension “b” is measured at the maximum ball diameter, parallel to the primary datum C.
8. Pin “A1” is marked on the top and bottom sides adjacent to A1.
bbb C
aaa C
C
A
SEATING PLANE
9. “S” is measured with respect to datum’s A and B and defines the
position of the solder balls nearest to package centerlines. When
there is an even number of balls in the outer row the value is
“S” = e/2.
SIDE VIEW
© Copyright Intersil Americas LLC 2004. All Rights Reserved.
All trademarks and registered trademarks are the property of their respective owners.
For additional products, see www.intersil.com/en/products.html
Intersil products are manufactured, assembled and tested utilizing ISO9001 quality systems as noted
in the quality certifications found at www.intersil.com/en/support/qualandreliability.html
Intersil products are sold by description only. Intersil may modify the circuit design and/or specifications of products at any time without notice, provided that such
modification does not, in Intersil's sole judgment, affect the form, fit or function of the product. Accordingly, the reader is cautioned to verify that datasheets are
current before placing orders. Information furnished by Intersil is believed to be accurate and reliable. However, no responsibility is assumed by Intersil or its
subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or
otherwise under any patent or patent rights of Intersil or its subsidiaries.
For information regarding Intersil Corporation and its products, see www.intersil.com
FN6006 Rev 3.00
Aug 2004
Page 71 of 71