Astrodyne FDC40-24S05 Isolated and regulated 40 watt modular dc/dc converter Datasheet

FDC40
I sol at e d a n d R e gul at ed 40 WATT Modula r DC/DC Co n ve rte rs
series
Wide 2 : 1 Input Range
High Efficiency
Regulated Outputs
1600V Isolation
Full EMI Shielding
PI Input Filter
Unit measures 2.76”W x 3.94”L x 0.75”H
Model Number
Output Voltage
SINGLE OUTPUT
FDC40-12S33
3.3 VDC
FDC40-24S33
FDC40-48S33
FDC40-12S05
5 VDC
FDC40-24S05
FDC40-48S05
FDC40-12S12
12 VDC
FDC40-24S12
FDC40-48S12
FDC40-12S15
15 VDC
FDC40-24S15
FDC40-48S15
WWW.ASTRODYNETDI.COM
Output Amps
Input Range
10
10
10
8
8
8
3.4
3.4
3.4
2.7
2.7
2.7
9-18 VDC
18-36 VDC
36-72 VDC
9-18 VDC
18-36 VDC
36-72 VDC
9-18 VDC
18-36 VDC
36-72 VDC
9-18 VDC
18-36 VDC
36-72 VDC
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
FDC40
I sol at e d a n d R e gul at ed 40 WATT Modula r DC/DC Co n ve rte rs
series
Wide 2 : 1 Input Range
High Efficiency
Regulated Outputs
1600V Isolation
Full EMI Shielding
PI Input Filter
Unit measures 2.76”W x 3.94”L x 0.75”H
Model Number
Output Voltage
Output Amps
Input Range
DUAL OUTPUT
FDC40-12D3305
3.3 / 5 VDC
FDC40-24D3305
FDC40-48D3305
FDC40-12D05
+/-5 VDC
FDC40-24D05
FDC40-48D05
FDC40-12D12
+/-12 VDC
FDC40-24D12
FDC40-48D12
FDC40-12D15
+/-15 VDC
FDC40-24D15
FDC40-48D15
4/4
4/4
4/4
+7 / -1
+7 / -1
+7 / -1
+/-1.8
+/-1.8
+/-1.8
+/-1.4
+/-1.4
+/-1.4
9-18 VDC
18-36 VDC
36-72 VDC
9-18 VDC
18-36 VDC
36-72 VDC
9-18 VDC
18-36 VDC
36-72 VDC
9-18 VDC
18-36 VDC
36-72 VDC
TRIPLE OUTPUT
FDC40-12T0512
5, +/-12 VDC
FDC40-24T0512
FDC40-48T0512
FDC40-12T0515
5, +/-15 VDC
FDC40-24T0515
FDC40-48T0515
4, +/-0.85
4, +/-0.85
4, +/-0.85
4, +/-0.68
4, +/-0.68
4, +/-0.68
9-18 VDC
18-36 VDC
36-72 VDC
9-18 VDC
18-36 VDC
36-72 VDC
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
FDC40
I sol at e d a n d R e gul at ed 40 WATT Modula r DC/DC Co n ve rte rs
INPUT SPECIFICATIONS
series
GENERAL SPECIFICATIONS
Input Voltage Ranges:
Input Filter
12 VDC Nominal
24 VDC Nominal
48 VDC Nominal
Pi Type
9-18 VDC
18-36 VDC
36-72 VDC
OUTPUT SPECIFICATIONS
Voltage and Current
See Selection Chart
Load Regulation
singles: +/-0.5%
duals: +/-1%
triples: 5 V:+/-2%, Aux: +/-5%
Line Regulation
singles: +/-0.5%
duals: +/-1%
triples: 5V:+/-2%, Aux:+/-5%
Temperature Coefficient
+/-0.02%/DegC
Ripple/Noise
1% Pk-Pk of Vout, typ
Voltage Stability
(singles/duals)
+/- 2%
(triples)
5 V:+/-2%, Aux: +/-5%
Short Circuit Protection
Continuous, self-recovering
Overvoltage Protection Threshold: 3.3V Output
3.9Volts
5V Output
6.2Volts
12V Output
15Volts
15V Output
18Volts
On/Off Control
Input-Out Isolation
Isolation Resistance
Efficiency
Switching Frequency
(Ref to - Input pin)
Logic “1”/Open=ON
Logic “0”/GND=OFF
1600VDC
10000 M Ohms
82%, typ
185Khz, typ
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature (Case)
Storage Temperature
Maximum Case Temp
MTBF
-25 to +85 DegC(see derate)
-55 to +125 DegC *
100 DegC *
1.61 MHrs
MIL-HDBK-217F TA=25C FL
PHYSICAL SPECIFICATIONS
Case Material
Construction
Weight
Nickel-Coated Copper
Non-Conductive Base
Fully Encapsulated
4.5 oz, (126g)
EFFICIENCY CURVES
90
89
88
87
86
85
84
83
82
81
80
FDC40-48S05
Efficiency VS Output load
EFFICIENCY (%)
EFFICIENCY (%)
FDC40-48S05
Efficiency VS Input Voltage
36
40
45
50
55
60
65
70
75
INPUT VOLTAGE (V)
90
89
88
86
84
82
80
70
60
50
45
0.5
1
2
3
4
5
6
7
8
OUTPUT LOAD (A)
All specifications are typical at nominal input, full load, and 25DegC unless
otherwise noted
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
FDC40
I sol at e d a n d R e gul at ed 40 WATT Modula r DC/DC Co n ve rte rs
series
EXTERNAL OUTPUT TRIMMING
MECHANICAL DIMENSIONS
Pin #
Single
Dual
Triple
1
2
3
4
5
6
7
8
9
10
Ctrl
+ Vin
- Vin
Sync
+ OutS
Trim
- OutS
+ Vout
- Vout
No Pin
Ctrl
+ Vin
- Vin
Sync
+ Vout or 3.3 out
Com
- Vout or 5 out
Trim
No Pin
No Pin
Ctrl
+ Vin
- Vin
Sync
+ Vout
Com
- Vout
+5 Out
-5 Out
Trim
OUTPUT DERATING CURVE
OUTPUT POWER (%)
FDC40-48S05 Derating Curve
100
75
50
Nature convection
25
0
-40 -25 -10
0
50
60
70
80
90
100
AMBIENT TEMPERATURE (ºC)
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
I sol at e d a n d R e gul at ed 40 WATT Modula r DC/DC Co n ve rte rs
FDC40
series
APPLICATION OF SYNCHRONIZATION
1. The unit is capable of external synchronization from an independent
time base with a switching rate between 200kHz and 215kHz
2. The amplitude of the synchronizing pulse train is TTL compatible
3. The duty cycle of the CLK should be 20% high and 80% low
4. Synchronization is referenced to negative input (-Vin)
Converter 1
2
+ Vin
4
3
- Vin
+
Sync
Converter 2
2
4
3
+
Sync
ON/OFF Control application
-
Converter
+ Vin
CLK
CLK Signal
2
1
2N7000
80%
- Vin
3
+
CTRL
-
ON/OFF Control
20%
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458