LAMBDA MZS1206 Equipment designed to conform emi regulations such as vcci,cispr,fcc,vde,etcã ã Datasheet

MZS-SERIES
䡵 Features
(1) Attenuation effect against high voltage pulse
noise
(2) For equipment designed to conform EMI
regulations such as VCCI, CISPR, FCC, VDE,
etc.
(3) Attenuates conductive emission from power
supply
(4) Leakage current: 1mA max. (250V, 60Hz)
(5) High shielded effect
MZS-1215
䡵 Safety standard
MZS-1220
(
MZS-1206
MZS-1210
UL1283,
CSA Std. C22. 2 No. 8
VDE0565 Teil. 3
VDE0565 will transfer to EN133200
on and after July 23, 2003.
)
䡵 Specifications
Model
Item
1
Rated voltage (AC, DC)
MZS-1206-33
MZS-1210-33
2
Rated current (AC, DC)
3
Test voltage (terminal to case, AC 1 minute)
2500V
4
Isolation resistance (terminal to case, 500VDC)
100MΩ min.
5
Leakage current
MZS-1215-33
MZS-1220-33
15A
20A
0.03Ω max.
0.02Ω max.
250V
(Note)
6A
10A
125V, 60Hz
0.5mA max.
250V, 60Hz
6
DC resistance
7
Temperature rise
8
Operating temperature range
9
Weight
1mA max.
0.10Ω max.
0.05Ω max.
30°C max.
–25 ~ +85°C
(typ)
310g
(Note) : Value at Ta <
= 55°C. Refer to the derating curve shown below at Ta > 55°C.
Noise Filter
䡵 Circuit
䡵 Derating
R: Breeder resistance
䡵 Outline drawings
Case: Metal
䢇 Request customer specification for further details of specifications, outline, characteristics, etc.
Read the instruction manual before usage.
䢇 Contact us about delivery before ordering.
(Unit: mm)
165
MZS-SERIES
CHARACTERISTICS
Attenuation (dB)
.............. Symmetrical
———— Asymmetrical
Attenuation (dB)
䡵 Typical Insertion Loss
Frequency (MHz)
Frequency (MHz)
Attenuation (dB)
Attenuation (dB)
Noise Filter
Frequency (MHz)
166
Frequency (MHz)