Mean Well MHB150-48S05 150w dc-dc half-brick regulated single output converter Datasheet

150W DC-DC Half-Brick Regulated Single Output Converter
MHB150
series
Features :
Half-brick size (2.28" 2.4" 0.5") with industry standard pin out
2:1 wide input range
Protections: Short circuit / Over current / Over voltage / Over temperature
High efficiency up to 89%
1500VDC I/O isolation
Built-in remote ON/OFF control
Built-in remote sense function
Trimming output 10%
Five-sided shield metal case
Optional heat sinks for extended operating temperature
Output 2.5V/3.3V/15V available
Approvals: UL / CUL / CE
3 years warranty
SPECIFICATION
MODEL
MHB150-48S05
MHB150-48S24
DC VOLTAGE
5V
12V
24V
CURRENT RANGE
0 ~ 30A
0 ~ 12.5A
0 ~ 6.25A
RATED POWER
150W
150mVp-p
240mVp-p
12500uF
6250uF
RIPPLE & NOISE (max.) Note.2 100mVp-p
OUTPUT
MHB150-48S12
VOLTAGE ACCURACY Note.3
1.0%
LINE REGULATION
0.2%
LOAD REGULATION
0.2%
SWITCHING FREQUENCY (Typ.) 500KHz
EXTERNAL TRIM ADJ. RANGE (Typ.) 10%
EXTERNAL CAPACITIVE LOAD (max.) 30000uF
48VDC
RATED DC INPUT
VOLTAGE RANGE
36 ~ 75VDC
INPUT
SURGE VOLTAGE (100ms max.) 100VDC
UNDER VOLTAGE LOCKOUT Power up: 34VDC, Power down: 32.5VDC
89%
EFFICIENCY (Typ.)
86%
FULL LOAD 3.7A
3.6A
DC CURRENT
NO LOAD
25mA
FILTER
Pi-network
OUTPUT OVER CURRENT
PROTECTION OUTPUT OVER VOLTAGE (Typ.)
OUTPUT SHORT CIRCUIT
89%
3.6A
110 ~ 140% rated output power
Protection type : Over current limiting, recovers automatically after fault condition is removed
115 ~ 140% rated output voltage
Protection type : Output voltage clamp
Protection type : Can be continuous, recovers automatically after fault condition is removed
100
5 of case temperature
OVER TEMPERATURE
Please refer to "Remote ON/OFF Control" for details
REMOTE CONTROL
FUNCTION
OPERATING OUTPUT TRIMMING
10%, Please refer to "External Output Trimming" for details
5 of case temperature (please refer to "Thermal Curve")
WORKING TEMPERATURE (Typ.) -40 ~ +100 ; Thermal shutdown at 100
0% ~ 95% RH max.
WORKING HUMIDITY
ENVIRONMENT
STORAGE TEMP., HUMIDITY -55 ~ +105 , 0 ~ 95% RH
TEMP. COEFFICIENT
SAFETY STANDARDS
SAFETY & ISOLATION VOLTAGE
ISOLATION RESISTANCE
EMC
(Note 4)
EMC EMISSION
OTHERS
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class A with external components (please refer to "EMC Suggestion Circuit")
EMC IMMUNITY
CASE MATERIAL
Compliance to EN61000-4-2,3,4,5,6,8; EN55024, light industry level, criteria A
MTBF
900K hrs typ. MIL-HDBK-217F (25 )
57.9*61*12.7mm (2.28"*2.40"*0.5") (L*W*H)
100g
DIMENSION
WEIGHT
NOTE
0.03%/ (0~60
UL60950-1 approved
I/P-O/P:1500VDC, I/P-Case:1500VDC, O/P-Case:1500VDC
Aluminum
1. All parameters NOT specially mentioned are measured at 48VDC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 1uf ceramic & 10uf tantalum capacitor across output.
3. The power supply need to connect "+Vout" to "+R.S" and "-Vout" to "-R.S".
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
File Name:MHB150-SPEC 2011-09-08
MHB150
150W DC-DC Half-Brick Regulated Single Output Converter
Mechanical Specification
series
Unit:inch[mm]
All Dimensions In Inches [mm]
Tolerance Inches: X.XX= 0.02 , X.XXX= 0.010
Millimeters: X.X= 0.5 , X.XX= 0.25
0.18 min. 0.50
[4.6] [12.7]
Mounting Inserts M3*0.5
R1.50
5
3
6
0.04
[1.02]
4
0.60
[15.24]
1.40
[35.56]
2.00
[50.8]
2.40
[61.0]
0.08
[2.03]
BOTTOM VIEW
7
2
8
1
9
SIDE VIEW
1.90
[48.3]
2.28
[57.9]
Pin No. Assignment
Pin No.
Assignment
Pin No.
Assignment
Pin No.
Assignment
1
2
+Vin
-Vin
7
Trim
R.C.
4
5
-Vout
8
+R.S.
3
Case
6
-R.S.
9
+Vout
Remote ON/OFF Control
The MHB150 series allow the user to switch the power ON and OFF electronically by their remote ON/OFF feature.
The MHB150 series are available with "Positive Logic" (standard) or "Negative Logic" (option).
Logic table
Logic State(pin2)
Positive logic
Negative logic
Logic Low-Switch Closed
Power OFF(<0.8Vdc)
Power ON(<0.8Vdc)
Logic High-Switch Open
Power ON(Open circuit) Power OFF(Open circuit)
Note: 1.Logic compatibility : R.C.(pin2) ~ -Vin(pin4).
2.Suffix "N" to the model number with Negative logic remote ON/OFF.
R.C.(pin2)
MHB150
High singal here
disable output
-Vin(pin4)
Example control circuit(positive logic)
File Name:MHB150-SPEC 2011-09-08
MHB150
150W DC-DC Half-Brick Regulated Single Output Converter
series
External Output Trimming
+Vin
(pin1)
+Vout
(pin9)
MHB150
+Vin
(pin1)
Trim
(pin7)
MHB150
R Trim-up
-Vin
(pin4)
+Vout
(pin9)
-Vout
(pin5)
RTrim-down
Trim
(pin7)
R -Load
R -Load
-Vin
(pin4)
-Vout
(pin5)
Figure 1 : Trim-up voltage setup
Figure 2 : Trim-down voltage setup
The value of RTrim-up defined as:
The value of R Trim-down defined as:
(R1-R2 (Vo-Vo, nom))
RTrim-up =
(Vo-Vo, nom)
(K )
(R1-R2 (Vo, nom-Vo))
R Trim-down =
(Vo, nom-Vo)
(K )
Where: R Trim-up is the external resistor in Kohm.
Where: R Trim-down is the external resistor in Kohm.
Vo,nom is the nominal output voltage.
Vo,nom is the nominal output voltage.
Vo is the desired output voltage.
Vo is the desired output voltage.
R1 and R2 are inside the unit and list in Table 1
R1 and R2 are inside the unit and list in Table 2.
Output
Voltage(V)
R1
(Kohm)
R2
(Kohm)
Output
Voltage(V)
R1
(Kohm)
R2
(Kohm)
5V
5.8
3.3
5V
5.8
5.32
12V
18.945
4.636
12V
86.45
60.1
24V
41.442
6.977
24V
430
120
Table 1
Table 2
For example, to Trim-up the output
For example, to Trim-down the output
voltage of 5.0V model (MHB150-48S05)
Voltage of 5.0V model (MHB150-48S05)
by 8% to 5.4V, RTrim-up is calculated
by 8% to 4.6V, RTrim-down is
as follows:
calculated as follows :
Vo - Vo,nom = 5.4 -5.0 = 0.4V
Vo,nom - Vo = 5.0 - 4.6 = 0.4 V
R1 = 5.8 Kohm
R1 = 5.8 Kohm
R2 = 3.3 Kohm
R2 = 5.32 Kohm
5.8-3.3 0.4
R Trim-up=
0.4
5.8-5.32 0.4
= 11.2 (K )
R Trim-down =
0.4
= 9.18 (K )
File Name:MHB150-SPEC 2011-09-08
150W DC-DC Half-Brick Regulated Single Output Converter
MHB150
series
Thermal Curve
The operating case temperature range of MHB-150 series is -40 oC to +100 oC. When operate the MHB-150 series, proper de-rating or
cooling is needed.
o
The maximum case temperature under any operating condition should not be exceed 100 C. The following curve is the de-rating
curve of MHB-150 series without heat sink.
Power Dissipated vs Amb ient Temperature and Air Flow without heatsink
50
Na tural Co nvection
20 ft. /min. (0.1 m/s)
100 f t./min. (0 .5 m/s)
45
40
Power Disspated, Pd (Watts )
200 f t./min. (1 .0 m/s)
35
300 f t./min. (1 .5 m/s)
30
25
400 f t./min. (2 .0 m/s)
20
500 f t./min. (2 .5 m/s)
15
600 f t./min. (3 .0 m/s)
10
700 f t./min. (3 .5 m/s)
5
800 f t./min. (4 .0 m/s)
0
0
10
20
30
40
50
60
Ambi ent Temperature, Ta (
Air Flow Rate
Natural convection
20ft./min. (0.1m/s)
100 ft./min. (0.5m/s)
Typical Rca
70
80
90
100
)
Air Flow Rate
Typical Rca
7.12
/W
500 ft./min. (2.5m/s)
2.96
/W
6.21
/W
600 ft./min. (3.0m/s)
2.53
/W
200 ft./min. (1.0m/s)
5.17
/W
700 ft./min. (3.5m/s)
2.37
/W
300 ft./min. (1.5m/s)
4.29
/W
800 ft./min. (4.0m/s)
2.19
/W
400 ft./min. (2.0m/s)
3.64
/W
Rca : Thermal resistance from case to
ambience
Example:
What is the minimum airflow necessary for a MHB150-48S12 operates at nominal line, an output current of 12.5A, and a maximum ambient
temperature of 40 ?
Solution:
Given: Vin=48Vdc, Vo=12Vdc, Io=12.5A, (unit efficiency)=89%
Determine Power dissipation (P d ):
P d =Pi-Po=Po(1- )/
P d =12 12.5 (1-0.89)/0.89=18.54 Watts
Determine airflow:
Given: P d =18.54W and Ta=40
Check Thermal Curve above:
minimum airflow= 500 ft./min.
Verifying: The maximum temperature rise T = P d Rca= 18.54 2.96=54.88
The maximum case temperature Tc=Ta+ T= 94.88 <100
Where: The Rca is thermal resistance from case to ambience.
The Ta is ambient temperature and the Tc is case temperature.
File Name:MHB150-SPEC 2011-09-08
MHB150
150W DC-DC Half-Brick Regulated Single Output Converter
series
Case Heat Sink (Optional)
Unit:mm
Model No.: M-C308 (Vertical Fins)
Model No.: M-C091(Horizontal Fins)
58
61
61
48.20
50.8
50.8
48.2
58
48.2
3.3
58
50.80
4-
60.70
Model No.: M-C092 (Horizontal Fins)
2.-8.50
8-2
5.-7.80
25.4
2.7
12.7
2.7
21
3 0.3
R1
CR0.3
0.30
Rca:
3.90
1.74
1.33
1.12
0.97
/ W (typ.), at natural convection
/ W (typ.), at 100ft./min.(LFM)
/ W (typ.), at 200ft./min.(LFM)
/ W (typ.), at 300ft./min.(LFM)
/ W (typ.), at 400ft./min.(LFM)
Rca:
4.70
2.89
2.30
1.88
1.59
/ W (typ.), at natural convection
/ W (typ.), at 100ft./min.(LFM)
/ W (typ.), at 200ft./min.(LFM)
/ W (typ.), at 300ft./min.(LFM)
/ W (typ.), at 400ft./min.(LFM)
Rca:
3.00
1.44
1.17
1.04
0.95
/ W (typ.), at natural convection
/ W (typ.), at 100ft./min.(LFM)
/ W (typ.), at 200ft./min.(LFM)
/ W (typ.), at 300ft./min.(LFM)
/ W (typ.), at 400ft./min.(LFM)
File Name:MHB150-SPEC 2011-09-08
150W DC-DC Half-Brick Regulated Single Output Converter
MHB150
series
Heatsink Assembly
Screw
Washer
Heat Sink
Thermal Pad or suitable
thermal grease
Heat Sink Order No.:
M-C308
M-C091
M-C092
Thermal Pad: 56.9x60x0.25mm
Screw: SMP+SW M3x8L
1
2
3
4
EMC Suggestion Circuit
Required external components to meet EN55022 class A conducted emission are as below:
L1
+Vin
+Vin
C1
+Vout
+Vout
MHB150
C2
-Vin
-Vin
Case
Lo ad
-Vout
-Vout
C3
C4
Model No.
MHB150-48S
C1
C2
C3
C4
L1
47uF/100V
ESR<0.17
47uF/100V
ESR<0.17
1000pF
1000pF
3.4uH
=05,12,24
File Name:MHB150-SPEC 2011-09-08