XP Power MCS65US28-D9 Rugged desktop design Datasheet

ACDC
65 Watts
MCS Series
xppower.com
•
Rugged Desktop Design
•
65 W ConvectionCooled
•
IP67 Ingress Protection
•
Wide Operating Temp. Range 40°C to +70°C
•
MILSTD EMC, Shock & Vibration
•
<0.5 W No Load Input Power
•
3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
General
•
•
•
•
Power Factor
•
No Load Input Power •
Earth Leakage Current •
Input Protection
•
90-264 VAC
47-440 Hz
1.1/0.7 A typical at 115/230 VAC
60 A typical at 230 VAC,
cold start at 25 ˚C
EN61000-3-2, class A compliant
<0.5 W
260 µA at 264 VAC/60 Hz max, 0.7/1.5 mA
typical 115/230 VAC 400 Hz.
Internal T3.15/250 V fuse in line and
neutral
Output
Output Voltage
Output Voltage Trim
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Drift
Total Regulation
Transient Response
•
•
•
•
•
•
•
•
•
Ripple & Noise
Overvoltage Protection
Overload Protection
Short Circuit Protection
Temperature
Coefficient
•
•
•
•
•
12-28 VDC (see table)
No user adjustment
No minimum load required
1 s typical
50 ms
16 ms typ. at 115 VAC
±0.2% after 20 min warm up
See table
4% max. deviation, recovery to within
1% in 500 µs for a 50-75-50% load
change
1% pk-pk, 20 MHz bandwidth(1)
115-140% Vnom, recycle input to reset
110-160%
Continuous trip and restart (hiccup mode)
0.05%/˚C
Notes
1. Measured at the end of the output cable with 10 µF electrolytic and 0.1 µF
ceramic capacitor.
Efficiency
Isolation
Switching Frequency
MTBF
• Up to 88% model dependent
• 4000 VAC Input to Output, 1500 VAC Input
to Ground, 500 VDC Output to Ground,
• 65 KHz typical
• 1057 kHrs, to MIL-HDBK-217F at 25 ˚C, GB
Environmental
Operating Temperature • -40 ˚C to +70 ˚C derate linearly from +50 ˚C
at 2.5%/˚C to 50% load at +70 ˚C. See
derating curves.
Cooling
• Convection-cooled (see tables)
Operating Humidity
• 95% RH, non-condensing
Storage Temperature • -40 ˚C to +85 ˚C
Operating Altitude
• 3048 m
Shock
• MIL-STD-810F, Method 516, Procedure 1
40g, 3 shocks, 6 axis, total 18 shocks,
operational
Vibration
• MIL-STD-810F, Method 514, Procedure 1
(fig 514.5C-3 composite wheeled vehicle)
5 - 500Hz, 3 axis, operational.
Ingress Protection
• IP67
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Other Immunity
• MIL-STD-461F - Ground Army, CE102.
MIL-STD-461F - Ground Army, RE102.
Figure RE102-3 fixed wing external 2MHz 18GHz. EN55011/22 level B conducted
EN55011/22 level A radiated
• EN61000-3-2, class A
• EN61000-3-3
• EN61000-4-3, level 3 Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, class 3
Perf Criteria A
• EN61000-4-6, level 3 Perf Criteria A
• EN61000-4-11, Class 3
• MIL-STD-461F - Ground Army, CS101,
Conducted Susceptibility, Power Leads, 30 Hz
to 150 kHz. - CS101-1 Curve #1 CS114,
Conducted Susceptibility, Bulk Cable Injection,
10 kHz to 200 MHz CS114-1 Curve #2,
CS115, Conducted Susceptibility, Bulk
Cable Injection, Impulse Excitation. CS116,
Conducted Susceptibility, Damped
Sinusoidal Transients, Cables and Power
RS103, Radiated Susceptibility, Electric Field,
2 MHz to 40 GHz. Table VII - Ground Limits
Output Power
65
65
65
65
65
Output Voltage
W
W
W
W
W
12.0
15.0
18.5
24.0
28.0
Output Current
VDC
VDC
VDC
VDC
VDC
5.4
4.3
3.4
2.7
2.3
Regulation
A
A
A
A
A
11.40V
14.25V
17.10V
22.80V
26.60V
-
Model Number(1)
12.60V
15.75V
18.90V
25.20V
29.40V
MCS65US12-D9
MCS65US15-D9
MCS65US18-D9
MCS65US24-D9
MCS65US28-D9
Notes
1. These models are supplied with integral US style AC plug, for UK or EU alternatives add suffix -UK or -EU respectively e.g. MCS65US12-D9-EU.
Mechanical Details
0.81
(20.5)
1.50
(37.8)
0.81
(20.5)
0.52 (13.2)
4 x 0.15
(3.8)
0.52 (13.2)
US version
48.0 (1219)
Female 9 pin D-SUB connector with gold plated
pins and 4-40 thumbscrews
2 X 6-32 customer mouting
max. screw length 0.375 (9.5)
3.5 (88.9)
1.0 (25.4)
NEMA 5-15P plug
0.62 (15.7)
2.75
(69.85)
2.25 (57.0)
UK version
Plug UK BS1363A
with 13 A fuse
Cordage: HO5/w-F,
3 x 1.0 mm
5.5 (139.7)
36.75 ±2.0 (935.0 ±50)
Pin
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Notes
1. All dimensions in inches (mm).
Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25),
except output cable length
2. Weight: 2.50 lbs (1.13 Kg)
Ouput Connector
Connection
Ground
N/C
N/C
+Vout
+Vout
D-SUB 9 Pin
Pin
Connection
Pin 6
N/C
Pin 7
N/C
Pin 8
-Vout
Pin 9
-Vout
EU version
Plug: Continental,
European CEE 7/7
Cordage: HO5W,
3 x 1.0 mm
Derating Curves
50
0
-40
Some specification
parameters may not be met
Output Load (%)
100
-20
0
+50
+70
Ambient Temperature (ºC)
20-May-13
ACDC
MCS65
Models and Ratings