NAIS AGN200A06Z Ultra-small package slim polarized relay Datasheet

GN
TESTING
ULTRA-SMALL PACKAGE
SLIM POLARIZED RELAY
GN-RELAYS
FEATURES
• Compact slim body saves space
Thanks to the small surface area of 5.7
mm × 10.6 mm .224 inch × .417 inch and
low height of 9.0 mm .354 inch, the packaging density can be increased to allow
for much smaller designs.
• Outstanding surge resistance.
Surge withstand between open contacts:
1,500 V 10×160 µs (FCC part 68)
Surge withstand between contacts and
coil: 2,500 V 2×10 µs (Bellcore)
5.70±0.3
.224±.012
10.60±0.3
.417±.012
9.00±0.3
.354±.012
10.60±0.3
.417±.012
5.70±0.3
.224±.012
Max.10.00
.394
mm inch
• The use of twin crossbar contacts ensures high contact reliability.
AgPd contact is used because of its good
sulfide resistance. Adopting low-gas
molding material. Coil assembly molding
technology which avoids generating volatile gas from coil.
• Increased packaging density
Due to highly efficient magnetic circuit design, leakage flux is reduced and changes
in electrical characteristics from components being mounted close-together are
minimized. This all means a packaging
density higher than ever before.
• Nominal operating power: 140 mW
• Outstanding vibration and shock resistance.
Functional shock resistance:
750 m/s2 {75G}
Destructive shock resistance:
1,000 m/s2 {100G}
Functional vibration resistance:
10 to 55 Hz (at double amplitude of 3.3
mm .130 inch)
Destructive vibration resistance:
10 to 55 Hz (at double amplitude of 5 mm
.197 inch)
SPECIFICATIONS
Contact
Characteristics
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1A )
Contact material
Rating
Nominal
operating
power
Expected
life (min.
operations)
Nominal switching capacity
(resistive load)
Max. switching power
(resistive load)
Max. switching voltage
Max. switching current
Min. switching capacity ❇1
Single side stable
1 coil latching
Mechanical (at 180 cpm)
1 A 30 V DC
resistive
Electrical
(at 20 cpm) 0.3 A 125 V AC
resistive
2 Form C
100 mΩ
Stationary: AgPd+Au clad
Movable: AgPd
1 A 30 V DC
0.3 A 125 V AC
30 W, 37.5 V A
110 V DC, 125 V AC
1A
10 µA 10 mV DC
140mW (1.5 to 12 V DC)
230mW (24 V DC)
100mW (1.5 to 12 V DC)
120mW (24 V DC)
5 × 107
105
105
Remarks:
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage" section.
*2 Detection current: 10mA.
*3 Nominal voltage applied to the coil, excluding contact bounce time.
*4 By resistive method, nominal voltage applied to the coil; contact carrying current:
1 A.
*5 Half-wave pulse of sine wave: 6 ms; detection time: 10µs.
6
* Half-wave pulse of sine wave: 6 ms.
*7 Detection time: 10µs.
*8 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61)
Initial insulation resistance*1
Min. 1,000MΩ (at 500V DC)
Between
open
contacts
750 Vrms for 1min.
Initial
breakdown Between contact sets
1,000 Vrms for 1min.
voltage*2
Between contacts and coil
1,500 Vrms for 1min.
Between open contacts
1,500 V (FCC Part 68)
Initial surge (10×160 µs)
voltage
Between contacts and coil
2,500 V (Bellcore)
(2×10 µs)
Max. 4 ms (Approx. 2 ms)
Operate time [Set time]*3 (at 20°C)
[Max. 4 ms (Approx. 2 ms)]
Release time (without diode)
Max. 4 ms (Approx. 1 ms)
[Reset time]*3 (at 20°C)
[Max. 4 ms (Approx. 2 ms)]
Temperature rise*4 (at 20°C)
Max. 50°C
Functional*5
Min. 750 m/s2{75G]
Shock resistance
Destructive*6
Min. 1,000 m/s2{100G]
10 to 55 Hz at double
Functional*7
amplitude of 3.3 mm
Vibration resistance
10 to 55 Hz at double
Destructive
amplitude of 5 mm
Conditions for opera- Ambient
–40°C to 85°C
tion, transport and
temperature ❇2
–40°F to 185°F
storage*8
(Not freezing and conHumidity
5 to 85% R.H.
densing at low temperature)
Unit weight
Approx. 1 g.035 oz
Notes:
❇1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
❇2 The upper limit for the ambient temperature is the maximum temperature that
can satisfy the coil temperature rise. Under the packing condition, allowable
temperature range is from –40 to +70°C –40° to +158°F.
125
GN
TYPICAL APPLICATIONS
• Telephone exchange, transmission
equipment
• Communications devices
• Measurement devices
• Home appliances, and audio/visual
equipment
• Handheld and portable products
ORDERING INFORMATION
Ex. AGN
Contact arrangement Operating function
2: 2 Form C
2
0
0
A
1
H
Z
Type of operation
Terminal shape
0: Standard type
(B.B.M.)
Nil: Standard PC board terminal
A: Surface-mount terminal A type
S: Surface-mount terminal S type
0: Single side stable
1: 1 coil latching
Packing style
Coil voltage (DC)
1H: 1.5V
03 : 3V
4H: 4.5V
06 : 6V
09 : 9V
12 : 12V
24 : 24V
Nil: Tube packing
Z: Tape and reel packing
(piked from 5/6/7/8
pin side)
Note: Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/2/3/4-pin side) is also available. Suffix “X” instead of “Z”.
TYPES AND COIL DATA (at 20°C 68°F)
(1) Standard PC board terminal
Part No.
Operating
Function
Standard PC
board terminal
AGN2001H
AGN20003
AGN2004H
AGN20006
AGN20009
AGN20012
AGN20024
Single side
stable
Coil Rating,
V DC
Pick-up voltage, V DC
(max.)
(initial)
Drop-out
voltage,
V DC (min.)
(initial)
Nominal
operating
current,
mA (±10%)
Coil resistance,
Ω (±10%)
Nominal
operating
power, mW
Max. allowable
voltage,
V DC
1.5
3
4.5
6
9
12
24
1.13
2.25
3.38
4.5
6.75
9
18
0.15
0.3
0.45
0.6
0.9
1.2
2.4
93.8
46.7
31
23.3
15.5
11.7
9.6
16
64.2
145
257
579
1,028
2,504
140
140
140
140
140
140
230
2.25
4.5
6.75
9
13.5
18
28.8
Coil Rating,
V DC
Set voltage,
V DC (max.)
(initial)
Reset voltage,
V DC (max.)
(initial)
Nominal
operating
current,
mA (±10%)
Coil resistance,
Ω (±10%)
Nominal
operating
power, mW
Max. allowable
voltage,
V DC
1.5
3
4.5
6
9
12
24
1.13
2.25
3.38
4.5
6.75
9
18
1.13
2.25
3.38
4.5
6.75
9
18
66.7
33.3
22.2
16.7
11.1
8.3
5.0
22.5
90
202.5
360
810
1,440
4,800
100
100
100
100
100
100
120
2.25
4.5
6.75
9
13.5
18
36
Part No.
Operating
Function
Standard PC
board terminal
1 coil latching
AGN2101H
AGN21003
AGN2104H
AGN21006
AGN21009
AGN21012
AGN21024
1) Standard packing: 50 pcs. in an inner package (tube); 1,000 pcs. in an outer package
2) Specified value of pick-up, drop-out, set and reset voltage is with the condition of square wave coil pulse.
(2) Surface-mount terminal
Part No.
Operating
Function
Single side
stable
Tube packing
Tape and reel
packing
AGN200❍1H
AGN200❍03
AGN200❍4H
AGN200❍06
AGN200❍09
AGN200❍12
AGN200❍24
AGN200❍1HZ
AGN200❍03Z
AGN200❍4HZ
AGN200❍06Z
AGN200❍09Z
AGN200❍12Z
AGN200❍24Z
Coil Rating,
V DC
1.5
3
4.5
6
9
12
24
Pick-up
voltage,
V DC (max.)
(initial)
1.13
2.25
3.38
4.5
6.75
9
18
Drop-out
voltage,
V DC (min.)
(initial)
0.15
0.3
0.45
0.6
0.9
1.2
2.4
Nominal
operating
current,
mA (±10%)
93.8
46.7
31
23.3
15.5
11.7
9.6
Coil
resistance,
Ω (±10%)
16
64.2
145
257
579
1,028
2,504
❍: For each surface-mounted terminal variation, input the following letter.
A type: A, S type: S
1) Standard packing: 50 pcs.(tube), 500pcs. (tape and reel)in an inner package; 1,000 pcs. in an outer package
2) Specified value of pick-up, drop-out, set and reset voltage is with the condition of square wave coil pulse.
126
Nominal
operating
power,
mW
140
140
140
140
140
140
230
Max.
allowable
voltage,
V DC
2.25
4.5
6.75
9
13.5
18
28.8
GN
Part No.
Operating
Function
1 coil
latching
Tube packing
Tape and reel
packing
AGN210❍1H
AGN210❍03
AGN210❍4H
AGN210❍06
AGN210❍09
AGN210❍12
AGN210❍24
AGN210❍1HZ
AGN210❍03Z
AGN210❍4HZ
AGN210❍06Z
AGN210❍09Z
AGN210❍12Z
AGN210❍24Z
Coil Rating,
V DC
Set voltage,
V DC (max.)
(initial)
1.5
3
4.5
6
9
12
24
1.13
2.25
3.38
4.5
6.75
9
18
Reset
voltage,
V DC (max.)
(initial)
1.13
2.25
3.38
4.5
6.75
9
18
Nominal
operating
current,
mA (±10%)
66.7
33.3
22.2
16.7
11.1
8.3
5.0
Coil
resistance,
Ω (±10%)
22.5
90
202.5
360
810
1,440
4,800
Nominal
operating
power,
mW
100
100
100
100
100
100
120
Max.
allowable
voltage,
V DC
2.25
4.5
6.75
9
13.5
18
36
❍: For each surface-mounted terminal variation, input the following letter.
A type: A, S type: S
1) Standard packing: 50 pcs.(tube), 500pcs. (tape and reel)in an inner package; 1,000 pcs. in an outer package
2) Specified value of pick-up, drop-out, set and reset voltage is with the condition of square wave coil pulse.
DIMENSIONS
mm inch
1. PC board terminal
PC board pattern
5.70±0.3
.224±.012
10.60±0.3
.417±.012
3.20
.126
(0.50) 9.00±0.3
(.020) .354±.012
3.50±0.3
.138±.012
0.40±0.1
.016±.004
0.25±0.1
.010±.004
2.20±0.15
.087±.006
3.20±0.15
.126±.006
(1.50)
(.059)
3.20±0.15
.126±.006
Schematic (Bottom view)
Single side stable
(Deenergized condition)
7.60
.299
3.20
.126
2.20
8-0.85 dia. .087
8-.033 dia
1
2 3 4
8
7 6 5
Direction indication
1 coil latching
(Reset condition)
1
2 3 4
8
7 6 5
Direction indication
Tolerance: ±0.1 ±.004
2. Surface-mount terminal
Suggested mounting pad
5.70±0.3
.224±.012
10.60±0.3
.417±.012
1) A type
(0.50) 9.00±0.3
(.020) .354±.012 Max. 10.00
.394
0.25±0.1
.010±.004
0.40±0.1
.016±.004
(1.50)
(.059)
2.20
.087
3.20
.126
3.10
.122
7.40±0.3
.291±.012
8
7 6 5
1
2 3 4
1 coil latcing
(Reset condition)
8
7 6 5
1
2 3 4
5.30
.209
3.20±0.15
.126±.006
2.20±0.15
.087±.006
3.20±0.15
.126±.006
Schematic (Top view)
Single side stable
(Deenergized condition)
0.80
.031
Direction indication
Direction indication
Tolerance: ±0.1 ±.004
Suggested mounting pad
5.70±0.3
.224±.012
10.60±0.3
.417±.012
1) S type
0.25±0.1
.010±.004
0.40±0.1
.016±.004
(1.50)
(.059)
2.25
.089
(0.50) 9.00±0.3
(.020) .354±.012 Max. 10.00
.394
4.45
.175
3.20±0.15
.126±.006
2.20±0.15
.087±.006
3.20±0.15
.126±.006
2.20
.087
3.20
.126
0.80
.031
5.70±0.3
.224±.012
Tolerance: ±0.1 ±.004
REFERENCE DATA
1. Max. switching capacity
2. Life curve
DC resistive load
AC resistive load
1.0
0.3
No. of operations, × 104
Switching current, A
100
50
40
30
DC 30V resistive load
20
AC 125V
resistive load
10
30
100
Contact voltage, V
0
0.2
0.4
0.6
0.8
1.0
1.2
Switching current, A
127
GN
NOTES
2) Tape and reel packing
(A type)
(1)-1 Tape dimensions
1. Coil operating power
1) As a general rule, only a pure DC power supply should be used for the coil drive.
2) To ensure proper operation, the voltage
applied to both terminals of the coil should
be ±5% (at 20°C 68°F) the rated operating
voltage of the coil. Also, be aware that the
pick-up and drop-out voltages will fluctuate depending on the ambient temperature and operating conditions.
3) The ripple factor for the voltage applied
to the coil should be less than 5%.
4) For set and reset latching relays, the
rated operating voltage should be applied
to the coil for 10 ms or more.
2. Coil connection
When connecting coils, refer to the wiring
diagram to prevent mis-operation or malfunction.
3. External magnetic field
Since GN relays are highly sensitive polarized relays, their characteristics will be
affected by a strong external magnetic
field. Avoid using the relay under that conditions.
4. Cleaning
In automatic cleaning, cleaning with the
boiling method is recommended. Avoid ultrasonic cleaning which subjects the relay
to high frequency vibrations. It may cause
the contacts to stick.
lt is recommended that a fluorinated hydrocarbon or other alcoholic solvent be
used.
5. Packing style
1) The relay is packed in a tube with the
relay orientation mark on the left side, as
shown in the figure below.
Orientation (indicates PIN No.1)stripe
Stopper (green)
Stopper (red)
mm inch
Relay polarity bar
(Z type)
4.00
.157
2.00
.079
1.50 +0.1
0 dia
.059 +.004
dia
0
0.40
.016
11.50
.453
1.75
.069
11.10
.437
10.70±0.2
.421±.008
2.00dia
.079dia
GN relays
16.00
.630
24.00±0.3
.945±.012
8.00
.315
Tape coming out direction
General tolerance ±0.1 mm .004 inch
(S type)
(1)-2 Tape dimensions
Relay polarity bar
(Z type)
1.50 +0.1
0 dia
.059 +.004
dia
0
4.00 2.0dia
.157 .079dia
1.75
.069
2.00
.079
10.70±0.2
.421±.008
0.40
.016
11.50
.453 24.00±0.3
.945±.012
11.10
.437
GN relays
16.00
.630
6.3
.248
Tape coming out direction
General tolerance ±0.1 mm .004 inch
(2) Dimensions of plastic peel
mm inch
21±0.8 dia.
.827±.031 dia.
2.0±0.5
.079±.020
100±1 dia.
3.937±.039 dia.
370±2 dia.
14.567±.079 dia.
13±0.2 dia.
.512±.008 dia.
24.4 +2
0
.961 +.079
0
2.0±0.2
.079±.008
6. Automatic insertion
To maintain the internal function of the
relay, the chucking pressure should not
exceed the values below.
Chucking pressure in the direction A:
4.9 N {500gf} or less
Chucking pressure in the direction B:
9.8 N {1 kgf} or less
Chucking pressure in the direction C:
9.8 N {1 kgf} or less
C
B
,
,
, ,,
A
Please chuck the
portion.
Avoid chucking the center of the relay.
In addition, excessive chucking pressure
to the pinpoint of the relay should be
avoided.
For Cautions for Use, see Relay Technical Information (Page 48 to 76).
128
9/1/2000
All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.
Go To Online Catalog
Similar pages