AC-DC 10 Watts xppower.com ECL10 Series • Ultra Compact Size • Low Cost • Single Outputs from 3.3 to 48 V • PCB Mount & Open Frame • Encapsulated PCB Mount • Class II • Peak Load Capability Specification Input Input Voltage Input Frequency Input Current Inrush Current Earth Leakage Current Input Protection General • • • • • • 85-264 VAC (120-370 VDC) 47-63 Hz 0.20 A rms at 230 VAC 20 A at 115 VAC, 40 A at 230 VAC, Class II construction no earth Internal 1 A fuse Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Line Regulation Load Regulation Transient Response • • • • • • • • • • Ripple & Noise • Overvoltage Protection Overload Protection Short Circuit Protection Temperature Coefficient • • • • See tables ±5% (not encapsulated units) ±1% No minimum load required 2 s max 14 ms max 16 ms typical at full load &115 VAC ±0.5% max ±1% max 4% max deviation, recovery to within 1% in 500 µs for a 25% load change 3.3-5 V versions: 50 mV pk-pk, 12-15 V versions: 120 mV pk-pk, 24-48 V versions: 200 mV pk-pk, 20 MHz BW 115-135% Vnom, recycle input to reset 120-150% Trip and restart (Hiccup mode) 0.05%/°C Output Efficiency Isolation Switching Frequency Power Density MTBF • • • • • See tables 3000 VAC Input to Output 70 kHz typical 5.5 W/In3 (PCB mount version) >450 kHrs per MIL-HDBK-217F Environmental Operating Temperature • -20 °C to +70 °C, derate linearly from 100% at +50 °C to 50% at +70 °C Cooling • Convection-cooled Operating Humidity • 95% RH, non-condensing Storage Temperature • -40 °C to +85 °C Operating Altitude • 3000 m Vibration • 2 g, 10 Hz to 500 kHz, 10 mins/cycle, 60 mins each cycle EMC & Safety Emissions Harmonic Currents ESD Immunity Radiated Immunity • • • • EFT/Burst Surge Conducted Immunity Magnetic Fields Dips & Interruptions • • • • • Safety Approvals • EN55022, level B conducted & radiated EN61000-3-2, EN61000-3-3 EN61000-4-2, level 3 Perf Criteria A EN61000-4-3, 10 V/m 80% mod Perf Criteria A EN61000-4-4, level 3 Perf Criteria A EN61000-4-5, level 3 Perf Criteria A EN61000-4-6, 10 Vrms Perf Criteria A EN61000-4-8, 10 A/m Perf Criteria A EN61000-4-11, 70% UT for 10 ms, 40% UT for 100 ms, <5% UT for 5000 ms Perf Criteria A, B, B EN60950, UL60950, CSA22.2 No. 234 per cUL Output Power 8.6 W 10 W 10 W 10 W 10 W 10 W 10 W Output Current Output Voltage 3.3 VDC 5.0 VDC 9.0 VDC 12.0 VDC 15.0 VDC 24.0 VDC 48.0 VDC Nominal 2.60 A 2.00 A 1.10 A 0.83 A 0.67 A 0.42 A 0.21 A Model Number(2) ECL10US03^† ECL10US05^† ECL10US09^† ECL10US12^† ECL10US15^† ECL10US24^† ECL10US48^† Efficiency Peak(1) 3.38 A 2.60 A 1.43 A 1.08 A 0.87 A 0.55 A 0.27 A 72% 75% 78% 78% 80% 82% 82% Notes 1. Peak load lasting <30 s with a maximum duty cycle of 10%, average output power not to exceed nominal. 2. Add suffix to model number to define type: add ‘-P’ for PCB mount, add ‘-T’ for chassis mount, add ‘-E’ for encapsulated. † Available from Farnell. See pages 204-206. ^ Available from Newark. See pages 207-208. Mechanical Details Open Frame - PCB Mount (-P) 0.800 (20.32) 2.000 (50.80) +Vo ACN 1.000 (25.40) 0.400 (10.16) V Adj. 0.100 (2.54) 0.100 (2.54) Encapsulated (-E) 0.100 (2.54) -Vo ACL 0.180 (45.72) 0.910 (23.00) 0.900 (22.86) 0.170 (4.40) 0.150 (3.80) 4 x ø 0.040 (ø1.00) 0.730 (18.46) 0.390 (10.00) 1.070 (27.20) ø 0.070 (ø1.80) 0.800 ±0.012 (20.32 ±0.30) ø 0.040 (ø1.00) 0.130 (3.40) 1.800 (45.72) Open Frame - Chassis Mount (-T) 2.060 (52.41) 2.600 (66.04) 4-ø0.126 (ø3.20) 1.000 (25.40) 0.685 (17.40) 0.157 (4.00) +Vo -Vo ACN ACL 0.157 (4.00) 1.800 ±0.012 (45.72 ±0.30) ACL 2.285 (58.04) 0.727 (18.47) TOP VIEW -Vo 0.130 (3.40) V Adj. ACN +Vo 0.400 ±0.012 (10.16 ±0.30) 0.850 (21.59) Notes 1. Dimensions in inches (mm). 2. Tolerances: x.xx = ± 0.02 (x.x = ± 0.5) x.xxx = ± 0.01 (x.xx = ± 0.25) Mating Connectors (Chassis mount only) Input Connector: JST PHR-3 Output Connector: JST PHR-2 Crimps: SPH-002T-P0.5S Cable harness with 300 mm wire available, order part no. ECL10 LOOM KIT 10-Oct-08 AC-DC ECL10 Models and Ratings