EIC HVR140 High voltage rectifier diode Datasheet

HVR125 - HVR180
HIGH VOLTAGE
RECTIFIER DIODES
PRV : 2500 - 8000 Volts
Io : 0.5 Ampere
DO - 41
FEATURES :
*
*
*
*
*
High current capability
High surge current capability
High reliability
Low reverse current
Low forward voltage drop
1.00 (25.4)
MIN.
0.107 (2.7)
0.080 (2.0)
0.205 (5.2)
0.166 (4.2)
MECHANICAL DATA :
* Case : DO-41 Molded plastic
* Epoxy : UL94V-O rate flame retardant
* Lead : Axial lead solderable per MIL-STD-202,
Method 208 guaranteed
* Polarity : Color band denotes cathode end
* Mounting position : Any
* Weight :
1.00 (25.4)
MIN.
0.034 (0.86)
0.028 (0.71)
0.339 gram
Dimensions in inches and ( millimeters )
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating at 25 °C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
SYMBOL
HVR
125
HVR
130
HVR
140
HVR
150
HVR
160
HVR
170
HVR
180
UNIT
Maximum Repetitive Peak Reverse Voltage
VRRM
2500
3000
4000
5000
6000
7000
8000
Volts
Maximum RMS Voltage
VRMS
1750
2100
2800
3500
4200
4900
5600
Volts
Maximum DC Blocking Voltage
VDC
2500
3000
4000
5000
6000
7000
8000
Volts
RATING
Maximum Average Forward Current
Ta = 50°C
IF(AV)
0.5
Amp.
IFSM
30
Amps.
Peak Forward Surge Current
8.3ms Single half sine wave Superimposed
on rated load (JEDEC Method)
Maximum Peak Forward Voltage at IF = 1.0 Amp.
VF
3.3
5.0
8.0
Volts
Maximum DC Reverse Current
Ta = 25°C
IR
5.0
µA
at Rated DC Blocking Voltage
Ta = 100°C
IR(H)
50
µA
Junction Temperature Range
TJ
- 40 to + 150
°C
Storage Temperature Range
TSTG
- 40 to + 150
°C
UPDATE : JUNE 16, 1998
RATING AND CHARACTERISTIC CURVES ( HVR125 - HVR180 )
FIG.2 - MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT
30
0.5
PEAK FORWARD SURGE
CURRENT, AMPERES
AVERAGE FORWARD OUTPUT
CURRENT, AMPERES
FIG.1 - DERATING CURVE FOR OUTPUT
RECTIFIED CURRENT
0.4
0.3
0.2
0.1
0 0
25
50
75
100
125
150
24
18
12
6
0
175
1
AMBIENT TEMPERATURE, ( °C)
2
4
6
10
20
40
60
100
NUMBER OF CYCLES AT 60Hz
FIG.3 - TYPICAL FORWARD CHARACTERISTICS
FIG.4 - TYPICAL REVERSE CHARACTERISTICS
10
10
HVR125 - HVR130
REVERSE CURRENT,
MICROAMPERES
FORWARD CURRENT,
AMPERES
TJ = 100 °C
1
HVR140 - HVR150
HVR160 - HVR180
0.1
Pulse Width = 300 µs
1% Duty Cycle
TJ = 25 °C
0.01
0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
1.0
0.1
TJ = 25 °C
0.01
9.0
FORWARD VOLTAGE, VOLTS
10
0
20
40
60
80
100
120
PERCENT OF RATED REVERSE
VOLTAGE, (%)
140
Similar pages