JMK EF-1356-10B Operating voltage = 115-250vac operating current = 10 amp Datasheet

JMK. Inc.
EF-1356-10B
Operating voltage = 115-250vac
Operating current = 10 amps
Operating frequency = 50-60 Hz
Operating temperature= -10 - +60 oC
Diel. withstanding (line-case)= 1500V~ for 1min
Diel. Withstanding = (line– line)= 1500Vdc for 1 min
Leakage current = 2.5ma @ 250Vac, 60Hz
Max residual voltage after 1 sec= 34V Max.
Agency approvals= cUL, CE
Order p/n: EF-1356-10B
The EF-1356-10B is an economical filter for use with
systems designed to function in the tempest or other
environment where the suppression of high
frequency emissions is important.
This filter features feed-through capacitors and has
insertion loss to beyond 1.0Ghz.
The filter is also encapsulated with an epoxy matrial
to make the filter capable of withstanding vibration
and shock. The vibration and shock levels can be
increased by supporting the rear of the enclosure in
order to eliminate any cantilever action