® MCWI02 SERIES DC/DC CONVERTER 2W, SIP-Package FEATURES ►Industrial Standard SIP-8 Package ►Ultra-wide 4 : 1 Input Voltage Range ►Fully Regulated Output Voltage ►I/O Isolation 1500 VDC ►Operating Ambient Temp. Range -40℃ to +90 ℃ ►No Min. Load Requirement ►Overload and Short Circuit Protection ►Remote On/Off Control ►UL/cUL/IEC/EN 60950-1 Safety Approval PRODUCT OVERVIEW The MINMAX MCWI02 series is a range of isolated 2W DC/DC converter modules featuring fully regulated output and ultra-wide 4:1 input voltage ranges. The product comes in a SIP-8 package with a very small footprint occupying only 2.0 cm2 (0.32 square in.) on the PCB. An excellent efficiency allows an operating temperature range up to 75°C at full load. Further features include remote On/Off control and over load protection. The very compact dimensions of these DC/DC converters make them an ideal solution for many space critical applications in battery-powered equipment and instrumentation. Model Selection Guide Model Number Input Voltage (Range) Output Voltage Output Current Input Current Max. capacitive Load Max. @Max. Load @No Load VDC VDC mA mA(typ.) mA(typ.) 3.3 500 MCWI02-12S05 5 MCWI02-12S12 12 Efficiency (typ.) @Max. Load μF % 183 1000 75 400 208 1000 80 167 204 170 82 15 134 204 110 82 ±5 ±200 208 470# 80 MCWI02-12D12 ±12 ±83 202 100# 82 MCWI02-12D15 ±15 ±67 204 47# 82 MCWI02-24S033 3.3 500 92 1000 75 MCWI02-24S05 5 400 104 1000 80 12 167 102 170 82 15 134 102 110 82 ±5 ±200 104 470# 80 MCWI02-24D12 ±12 ±83 101 100# 82 MCWI02-12S033 MCWI02-12S15 MCWI02-12D05 MCWI02-24S12 MCWI02-24S15 MCWI02-24D05 12 (4.5 ~ 18) 24 (9 ~ 36) 60 30 MCWI02-24D15 ±15 ±67 102 47# 82 MCWI02-48S033 3.3 500 46 1000 74 MCWI02-48S05 5 400 52 1000 80 MCWI02-48S12 12 167 51 170 82 MCWI02-48S15 48 (18 ~ 75) 15 134 51 110 82 ±5 ±200 52 470# 80 MCWI02-48D12 ±12 ±83 51 100# 82 MCWI02-48D15 ±15 ±67 51 47# 82 MCWI02-48D05 20 # For each output E-mail:[email protected] 2015/07/31 REV:1 Tel:886-6-2923150 Page 1 of 4 ® MCWI02 SERIES DC/DC CONVERTER 2W, SIP-Package Input Specifications Parameter Model 12V Input Models 24V Input Models 48V Input Models 12V Input Models 24V Input Models 48V Input Models 12V Input Models 24V Input Models 48V Input Models Input Surge Voltage (1 sec. max.) Start-Up Threshold Voltage Under Voltage Shutdown Short Circuit Input Power Input Filter All Models Min. -0.7 -0.7 -0.7 3 4.5 8.5 --------- Typ. Max. 25 --50 --100 --4 4.5 6 9 12 18 --4 --8 --16 --1500 Internal Capacitor Min. Typ. Unit VDC mW Remote On/Off Control Parameter Conditions Converter On Max. Unit mA Open or high impedance Converter Off 2~4mA current applied via 1Kohm resistor Standby Input Current Supply Off & Nominal Vin --- 2.5 --- Min. Typ. Max. Unit --- --- ±2.0 %Vnom. ----- ±1.0 ±2.0 % Output Specifications Parameter Conditions Output Voltage Setting Accuracy Output Voltage Balance Dual Output, Balanced Loads Line Regulation Vin=Min. to Max. @Full Load ±0.3 ±0.5 % Load Regulation Io=0% to 100% --±0.5 No minimum Load Requirement ±1.0 % 0-20MHz Bandwidth --- --- 100 mV P-P --- 300 500 μsec Minimum Load Ripple & Noise Transient Recovery Time 25% Load Step Change Transient Response Deviation Temperature Coefficient Over Load Protection Foldback Output Short Circuit --- ±3 ±5 % --- ±0.01 ±0.02 %/℃ 110 140 --- % Continuous, Automatic Recovery General Specifications Parameter Conditions 60 Seconds 1 Second 500 VDC 100KHz, 1V Min. Typ. Max. 1500 ----1800 ----1000 ------250 500 --300 --MIL-HDBK-217F@25℃, Ground Benign 3,430,000 ----UL/cUL 60950-1 recognition(CSA certificate), IEC/EN 60950-1(CB-scheme) I/O Isolation Voltage I/O Isolation Resistance I/O Isolation Capacitance Switching Frequency MTBF (Calculated) Safety Approvals Unit VDC VDC MΩ pF KHz Hours Environmental Specifications Parameter Conditions Min. Max. Unit Natural Convection -40 +90 ℃ Case Temperature --- +105 ℃ Storage Temperature Range -55 +125 ℃ Humidity (non condensing) --- 95 % rel. H 260 ℃ Operating Ambient Temperature Range (See Power Derating Curve) Cooling Natural Convection Lead Temperature (1.5mm from case for 10Sec.) E-mail:[email protected] 2015/07/31 REV:1 Tel:886-6-2923150 Page 2 of 4 --- ® MCWI02 SERIES DC/DC CONVERTER 2W, SIP-Package Power Derating Curve 100 Natural Convection 20LFM Output Power (%) 80 400LFM 60 40 20 0 ~ -40 0 20 40 60 80 100 110 Ambient Temperature C Notes 1 Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted. 2 Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%. 3 We recommend to protect the converter by a slow blow fuse in the input supply line. 4 Other input and output voltage may be available, please contact factory. 5 That “natural convection” is about 20LFM but is not equal to still air (0 LFM). 6 Specifications are subject to change without notice. Package Specifications Mechanical Dimensions 0.5 [0.02] 3.2 [0.13] 11.2 [0.44] 21.8 [0.86] Pin Connections Pin Single Output 1 -Vin 2 +Vin 3 Remote On/Off 5 NC 6 +Vout 7 -Vout 8 NC Dual Output -Vin +Vin Remote On/Off NC +Vout Common -Vout 0.5 [0.02] 2X2.54 5.08 [2X0.10] [0.20] 2.0 [0.08] 3X2.54 [3X0.10] NC: No Connection 3 5 6 7 8 9.3 [0.37] 2 0.25 [0.01] Bottom View 1 2.7 [0.11] 20.8 [0.82] 0.50 [0.02] Physical Characteristics Case Size : 21.8x9.3x11.2 mm (0.86x0.37x0.44 inches) Case Material : Non-Conductive Black Plastic (flammability to UL 94V-0 rated) Pin Material : : Alloy 42 Weight 4.66g E-mail:[email protected] 2015/07/31 REV:1 Tel:886-6-2923150 Page 3 of 4 ►All dimensions in mm ►Tolerance: X.X±0.5 (inches) (X.XX±0.02) X.XX±0.25 ( X.XXX±0.01) ►Pins ±0.1(±0.004) ® MCWI02 SERIES DC/DC CONVERTER 2W, SIP-Package Test Setup Peak-to-Peak Output Noise Measurement Test Use a Cout 0.47μF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter. +Vin +Out Copper Strip Single Output DC / DC Converter -Vin Cout -Out Scope Resistive Load Copper Strip +Vin +Out Copper Strip Dual Output DC / DC Converter Com. Copper Strip -Vin -Out Scope Cout Resistive Load Cout Scope Copper Strip Technical Notes Remote On/Off Negative logic remote on/off turns the module off during a logic high voltage on the remote on/off pin, and on during a logic low. To turn the power module on and off, the user must supply a switch to control the voltage between the on/off terminal and the -Vin terminal. A logic high is 2~4mA current applied via 1Kohm resistor. A logic low is open circuit or high impedance. Maximum Capacitive Load The MCWI02 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet. Overcurrent Protection To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back into its specified range. Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup. Capacitor mounted close to the power module helps ensure stability of the unit, it is commended to use a good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 KHz) capacitor of a 4.7μF for the 12V input devices and a 2.2μF for the 24V and 48V devices. + DC Power Source +Vin + +Out DC / DC Converter Load Cin - -Vin -Out Output Ripple Reduction A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 3.3μF capacitors at the output. + +Vin DC Power Source - +Out Single Output DC / DC Converter -Vin + Cout Load -Out +Vin DC Power Source - +Out Dual Output DC / DC Com. Converter -Vin -Out Cout Load Load Cout Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 105℃. The derating curves are determined from measurements obtained in a test setup. Position of air velocity probe and thermocouple 15mm / 0.6in 50mm / 2in Air Flow DUT 18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected] Minmax Technology Co., Ltd. 2015/07/31 REV:1 Page 4 of 4