XP Power ECP225PS48 150/225 w convection/ forced cooled Datasheet

ACDC
225 Watts
ECP Series
xppower.com
•
Low 1” Profile with 2.5” x 5” Footprint
•
150/225 W Convection/ Forcedcooled
•
High Efficiency up to 95%
•
Medical & ITE Approvals
•
Builtin Fan Supply
•
<0.5 W No Load Input Power
•
3 Year Warranty
Specification
Input
General
• 85-264 VAC, Derate from 100% at 90 VAC
to 90% at 85 VAC
Input Frequency
• 47-63 Hz
Input Current
• 2.2 A typical at 115 VAC, 1.1 A typical at
230 VAC
Inrush Current
• 120 A max at 230 VAC, cold start at 25 °C
Power Factor
• >0.95 at full load
Earth Leakage Current • <230 µA at 264 VAC, 60 Hz
No Load Input Power • <0.5 W
Input Protection
• Internal T3.15A/250VAC fitted in line and
neutral
Input Voltage
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
•
•
•
•
•
•
•
Line Regulation
Load Regulation
Transient Response
•
•
•
Ripple & Noise
•
Overvoltage Protection •
Overload Protection
Short Circuit Protection
Thermal Protection
Temperature
Coefficient
Fan Supply
•
•
•
•
See tables
±5%
±1% at 50 % load
No minimum load requirement
2 s max
55 ms typical
10 ms minimum at full load and 115 VAC
20 ms typical at 150 W, 13 ms typical at
225 W
±0.5% max
±0.5% max
4% maximum deviation, recovering to less
than 1% within 500 µs for 25% step load
1% max pk-pk, 20 MHz bandwidth,
(see note 2)
110% - 140% of nominal voltage on main
output. Recycle mains to reset.
110-170%
Trip and restart (hiccup)
Measured internally. Auto resetting.
0.02%/°C
Efficiency
Isolation
Protection Level
Power Density
Switching Frequency
MTBF
• See table
• 4000 VAC Input to Output
1500 VAC Input to Ground
1500 VAC Output to Ground
• Primary to Secondary: 2 MOPP
Primary to Earth: 1 MOPP
Secondary to Earth: 1 MOPP
• 12/18 W/in3 convection/forced-cooled,
• PFC: 70-130 KHz, PWM: 50-80 KHz
• >300 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature • -20 °C to +70 °C derate from 100% load
at 50 °C to 50% load at 70 °C
Cooling
• Convection cooled: 150 W
Forced cooled: 225 W with 10 CFM
Operating Humidity
• 5% to 90% RH, non condensing
Operating Altitude
• 5000 m
Storage Temperature • -40 °C to +85 °C
Shock
• IEC68-2-27, 30 g, 11 ms half sine, 3 times
in each of 6 axes
Vibration
• IEC68-2-6, 10-500 Hz, 2 g 10 mins /
sweep. 60 mins for each of 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
• 12 V at 500 mA
Safety Approvals
• EN55022/11, Level B conducted &
Level A radiated
• EN61000-3-2 Class A
EN61000-3-2 Class C for load >145 W
• EN61000-3-3
• EN61000-4-2, ±8 kV air, ±4 kV contact,
Perf Criteria A
• EN61000-4-3, 3 V/m, Perf Criteria A
• EN61000-4-4, level 3, Perf Criteria A
• EN61000-4-5, installation class 3,
Perf Criteria A
• EN61000-4-6, 3 V, Perf Criteria A
• EN55024, 30% 10 ms,
60%, 100 ms, 100%, 5000 ms
Perf Criteria A, A, B for high line,
A, B, B for low line at full load,
EN60601-1-2, 30% 500 ms, 60% 100 ms,
100% 10 ms, 100% 5000 ms,
Perf Criteria A, A, A, B for high line,
A, B, A, B for low line at full load
• UL60950-1, IEC60950-1, EN60950-1,
ANSI/AAMI ES 60601-1, IEC60601-1,
EN60601-1
Output Current
Convection-cooled
Forced-cooled(1)
Ripple and Noise
pk-pk(2)
Fan Output
Efficiency(3)
Model Number(4)
12.0 V
12.50 A
18.75 A
120 mV
12 V/0.5 A
93%
ECP225PS12
15.0 V
10.00 A
15.00 A
150 mV
12 V/0.5 A
93%
ECP225PS15
24.0 V
6.25 A
9.38 A
240 mV
12 V/0.5 A
94%
ECP225PS24
28.0 V
5.36 A
8.04 A
280 mV
12 V/0.5 A
94%
ECP225PS28
48.0 V
3.10 A
4.69 A
480 mV
12 V/0.5 A
94%
ECP225PS48
Output Voltage
Notes
3. Minimum average efficiencies measured at 25%, 50%, 75% & 100% of
225 W load and 230 VAC input.
4. 3” x 5” Footprint available for OEM quantities, add suffix ‘-3X5’to part eg.
ECP225PS24-3X5.
1. Requires 10 CFM.
2. Measured with 20 MHz bandwidth and 10 µF electrolytic capacitor in parallel
with 0.1 µF ceramic capacitor
Mechanical Details
CN1 - Input Connector
Pin 1
Neutral
Pin 2
Not Fitted
Pin 3
Line
5.00 (127.0)
4.75 (120.6)
0.25 (6.35) Faston ground tab
Mates with JST housing
VHR-3N and JST Series
SVH-21T-P1.1 crimp terminals
Mounting holes marked with
must be connected to safety earth
8
2.25
(57.1)
CN2 - Output Connector
Pin 1
-Vout
Pin 2
-Vout
Pin 3
-Vout
Pin 4
-Vout
Pin 5
+Vout
Pin 6
+Vout
Pin 7
+Vout
Pin 8
+Vout
VR
CN2
2.50
(63.5)
3
CN1
1
1
2
1
0.134 (Ø3.4 ±0.3)
Mates with JST housing
VHR-8N and JST Series
SVH-21T-P1.1 crimp terminals
CN3
Mounting Screw
Holes 4 Places
0.06
(1.60)
0.83 1.00
(21.0) (25.4)
CN3 - Fan Connector
Pin 1
Fan -
Pin 2
Fan +
Mates with Molex housing
22-01-1022 and 2759 crimp terminals
0.11
(2.80)
Notes
1. All dimensions shown in inches (mm).
Tolerance: ±0.02 (0.5)
2. Weight: 0.51 lbs (230 g) approx.
Derating Curve
Output Power (%)
100
80
60
40
20
0
-20
-10
0
10
20
30
40
50
60
70
80
Ambient Temperature (ºC)
11-Feb-13
ACDC
ECP225
Models and Ratings