BULGIN EXP-0911/07/S Exp series explora - hazardous area Datasheet

EXPLORA
EXP Series EXPlora - Hazardous Area
EXPLORA
IP68
Terminals
Sealing Gasket
O Ring
Contact Insert
O Ring
O Ring
O Ring
Locking Ring
Retaining
Nut
Main Body
Panel Body
Contact Insert
Terminals
Cable Gland
Gland Cage
Gland Nut
ᔢ ATEX approval for Zone 2 and Zone 22 applications
ᔢ Independently tested
ᔢ ATEX Coding:
ᔢ ATEX Classification:
II 3 GD
Ex nA IIC T6 Gc
Ex tc IIIC T85˚C Dc
ᔢ ATEX Certificate No:
Baseefa09ATEX0232X
ᔢ IP68 rating tested at 1.054kg/sq cm (15lb/sq in)
10m depth for 2 weeks
ᔢ
ᔢ
ᔢ
ᔢ
ᔢ
ᔢ
Up to 18A, 600V ac/dc rating
2, 3, 4, 5, 7 and 10 pole
Leading earth contact for 3, 4, 5 & 7 pole versions
Trailing Neutral on 5 pole
Plug or socket connection in each body style
Water and dustproof to IP68 when mated
www.bulgin.co.uk
ᔢ ‘Scoop proof’ contacts
ᔢ Field termination - screw terminations
ᔢ Positive locating keyways - cannot be
mis-connected
ᔢ Sealing caps available to maintain IP68 rating of
unmated connectors
ᔢ
ᔢ
ᔢ
ᔢ
ᔢ
ᔢ
Compact design
Easy assembly - no special tools required
Single or 3 phase applications
Cost effective solution
Cable acceptance from 7 to 22mm O/D
Two cable connector versions for 15mm and 22mm
(maximum) cable diameters
ᔢ Separate strain relief on large cable version
1
EXPLORA
EXP Series EXPlora - Hazardous Area Connector
EXPLORA
FLEX CABLE CONNECTOR
EXP-0911
ᔢ Mates with in-line flex or
panel mounting versions
ᔢ Positive, fast acting locking
ring - can be turned with a
gloved hand
ᔢ Plug or socket versions
ᔢ EXP-0 Series13-15mm cable
dia. acceptance as standard,
7-13mm with additional
gland pack
ᔢ EXP-A Series 20-22mm cable
dia. acceptance as standard,
14-20mm with additional
gland pack
ᔢ Strain Relief Clamp
(EXP-A Series only)
EXP-A911
Flex Cable
Standard Cable
Large Cable
Description
Standard Cable
Large Cable
Description
EXP-0911/02/P
EXP-0911/03/P
EXP-0911/04/P
EXP-0911/05/P
EXP-0911/07/P
EXP-0911/10/P
EXP-A911/02/P
EXP-A911/03/P
EXP-A911/04/P
EXP-A911/05/P
EXP-A911/07/P
EXP-A911/10/P
2 pole Plug
3 pole Plug
4 pole Plug
5 pole Plug
7 pole Plug
10 pole Plug
EXP-0911/02/S
EXP-0911/03/S
EXP-0911/04/S
EXP-0911/05/S
EXP-0911/07/S
EXP-0911/10/S
EXP-A911/02/S
EXP-A911/03/S
EXP-A911/04/S
EXP-A911/05/S
EXP-A911/07/S
EXP-A911/10/S
2 pole Socket
3 pole Socket
4 pole Socket
5 pole Socket
7 pole Socket
10 pole Socket
IN-LINE FLEX CABLE CONNECTOR
EXP-0921
ᔢ Mates with either EXP-0911
or EXP-A911 connectors
ᔢ Plug or socket versions
ᔢ EXP-0 Series13-15mm cable
dia. acceptance as standard,
7-13mm with additional
gland pack
ᔢ EXP-A Series 20-22mm cable
dia. acceptance as standard,
14-20mm with additional
gland pack
ᔢ Strain Relief Clamp
(EXP-A Series only)
EXP-A921
In-Line Flex Cable
Standard Cable
Large Cable
Description
Standard Cable
Large Cable
Description
EXP-0921/02/P
EXP-0921/03/P
EXP-0921/04/P
EXP-0921/05/P
EXP-0921/07/P
EXP-0921/10/P
EXP-A921/02/P
EXP-A921/03/P
EXP-A921/04/P
EXP-A921/05/P
EXP-A921/07/P
EXP-A921/10/P
2 pole Plug
3 pole Plug
4 pole Plug
5 pole Plug
7 pole Plug
10 pole Plug
EXP-0921/02/S
EXP-0921/03/S
EXP-0921/04/S
EXP-0921/05/S
EXP-0921/07/S
EXP-0921/10/S
EXP-A921/02/S
EXP-A921/03/S
EXP-A921/04/S
EXP-A921/05/S
EXP-A921/07/S
EXP-A921/10/S
2 pole Socket
3 pole Socket
4 pole Socket
5 pole Socket
7 pole Socket
10 pole Socket
2
www.bulgin.co.uk
EXPLORA
EXP Series EXPlora - Hazardous Area Connector
PANEL MOUNTING CONNECTOR
EXPLORA
ᔢ Mates with EXP-0911 and
EXP-A911 connectors
ᔢ Single hole fixing
ᔢ Anti-rotation key
ᔢ High grade sealing gasket
ᔢ 3-7mm panel thickness
EXP-0931
Panel Mounting
EXP-0931/02/P
EXP-0931/03/P
EXP-0931/04/P
EXP-0931/05/P
EXP-0931/07/P
EXP-0931/10/P
2 pole Plug
3 pole Plug
4 pole Plug
5 pole Plug
7 pole Plug
10 pole Plug
EXP-0931/02/S
EXP-0931/03/S
EXP-0931/04/S
EXP-0931/05/S
EXP-0931/07/S
EXP-0931/10/S
2 pole Socket
3 pole Socket
4 pole Socket
5 pole Socket
7 pole Socket
10 pole Socket
EXP-0941/02/S
EXP-0941/03/S
EXP-0941/04/S
EXP-0941/05/S
EXP-0941/07/S
EXP-0941/10/S
2 pole Socket
3 pole Socket
4 pole Socket
5 pole Socket
7 pole Socket
10 pole Socket
FLANGE MOUNTING CONNECTOR
EXP-0941
ᔢ Mates with EXP-0911 and
EXP-A911 connectors
ᔢ Supplied with high grade
sealing gasket
ᔢ Supplied with sealing
grommets for panel fixing
screws (M6 thread
recommended)
Flange Mounting
EXP-0941/02/P
EXP-0941/03/P
EXP-0941/04/P
EXP-0941/05/P
EXP-0941/07/P
EXP-0941/10/P
www.bulgin.co.uk
2 pole Plug
3 pole Plug
4 pole Plug
5 pole Plug
7 pole Plug
10 pole Plug
3
EXPLORA
EXP Series EXPlora - Hazardous Area Connector
Sealing Caps
ACCESSORIES
EXPLORA
ᔢ Heavy duty sealing caps to
maintain IP68 rating of
unmated connectors, with
stainless steel straps
EXP-0990
Heavy duty sealing cap for use with
EXP-0911/xx/x and EXP-A911/xx/x
EXP-0991
Heavy duty sealing cap for use with
EXP-0921/xx/x and EXP-A921/xx/x
EXP-0992
Heavy duty sealing cap for use with
EXP-0931 and EXP-0941
Gland Packs
EXP-0990, EXP-0991, EXP-0992
EXP-0980
Pack of 3 additional cable glands for
EXP-0911 and EXP-0921 to suit cable sizes;
11-13mm, 9-11 and 7-9mm dia.
EXP-A980
Pack of 3 additional cable glands for
EXP-A911 and EXP-A921 to suit cable sizes;
18-20mm, 16-18 and 14-16mm dia.
PART NO SYSTEM
E X P- 0 9 x x / x x / x / x
Series Designation
09 = Standard Cable Accommodation (7-13mm)
A9 = Large Cable Accommodation (14-22mm)
Body Styles
1 = Flex, 2 = Flex In-line,
3 = Panel, 4 = Flange Panel
Contact Termination
1 = Screw Terminal
Number Contacts
02 = 2 pole, 03 = 3 pole, 04 = 4 pole,
05 = 5 pole, 07 = 7 pole, 10 = 10 pole
Contact Type
P = Plug, S = Socket
Cable Acceptance
EXP-0 version:
Blank = 13-15mm
3 = 11-13mm
2 = 9-11mm
1 = 7-9mm
Yellow cable gland (standard)
Black cable gland
White cable gland
Dark Grey cable gland
EXP-A version:
Blank = 20-22mm
9 = 18-20mm
8 = 16-18mm
7 = 14-16mm
Yellow cable gland (standard)
Black cable gland
White cable gland
Dark Grey cable gland
Example:
EXP-0911/07/P/3 = Flex cable connector with standard cable accommodation body, seven
pin contacts, with gland to suit 11-13mm cable.
4
www.bulgin.co.uk
EXPLORA
EXP Series EXPlora - Hazardous Area Connector
SPECIFICATION
No Poles:
2, 3, 4, 5
7
10
Current Rating:
18A
16A
10A
Voltage Rating:
600Vac/dc
430Vac/dc
250Vac/dc
Contact Resistance:
<10mΩ (initial)
Insulation Resistance:
>106MΩ (@ 500V dc)
Dielectric strength:
2.2kV ac min
AC Breakdown voltage:
6kV
Ambient Temperature Range:
–20°C to +55°C
Standards:
ATEX Zone 2 and Zone 22
IEC60079-0:2007
IEC60079-15:2005
ATEX Coding:
II 3 GD
ATEX Certificate No:
Baseefa09ATEX0232X
ATEX Classification:
Ex nA IIC T6 Gc
Ex tc IIIC T85˚C Dc
Materials:
Body Mouldings:
Polyester
Flammability Rating:
UL94V-0
UV Resistance:
To EN50021:1999
Contacts:
Machined Solid Brass, Nickel plated
O Rings:
Nitrile
Panel Sealing Gasket:
Silicone Rubber
Sealing:
IP68, EN60529:2001 tested @
1.054kg/sq.cm. (15lb/sq.in.) 10m depth for
2 weeks
Cable Acceptance:
EXP-0911 - EXP-0921 13 - 15mm O/D standard,
7-13mm with gland pack
EXP-A911 - EXP-A921 20 - 22mm O/D standard,
14 - 20mm with gland pack
Contact Accommodation:
2.5 to 4mm2 (13 to10AWG) conductor,
single or multi stranded
Termination:
Axial screw terminals
Cable Retention force:
22mm dia, 150N
15mm dia, 150N
7mm dia, 80N
Gland Nut Torques:
EXP-0 range
13-15mm (Yellow - std.)
11-13mm (black)
9-11mm (white)
7-9mm (dark grey)
EXP-A range
20-22mm (Yellow - std.)
18-20mm (black)
16-18mm (white)
14-16mm (dark grey)
Tightening Torques:
Panel mount nut
Flange & Bulkhead
fixing screws
3.16Nm
3.16Nm
3.16Nm
3.16Nm
(28
(28
(28
(28
lb/in)
lb/in)
lb/in)
lb/in)
3.16Nm
3.16Nm
3.16Nm
3.16Nm
(28
(28
(28
(28
lb/in)
lb/in)
lb/in)
lb/in)
2.25 Nm
0.9 Nm
Dimensions:
Compliant
Overall dimensions of connectors when mated together
CONTACT LAYOUT
2 pole
3 pole
4 pole
5 pole
7 pole
10 pole
www.bulgin.co.uk
EXP-0911 + EXP-0921
EXP-A911 + EXP-A921
230 mm max.
270 mm max.
EXP-0911 + EXP-0931
EXP-A911 + EXP-A931
135 mm max. (to panel)
175 mm max. (to panel)
EXP-0911 + EXP-0941
EXP-A911 + EXP-A941
145 mm max. (to panel, mid point on flange)
174 mm max. (to panel, mid point on flange)
5
EXPLORA
Mechanical: