Schurter DLO1-24-0003 Linear choke, open version, without socket Datasheet

DLO
Suppression Chokes
www.schurter.com/pg81_82
Linear Choke, open version, without socket
Description
Applications
- Linear choke
- Wire leads
- Open version without socket and chassis
-
Standards
- EN 60938
Smoothing RFI suppression choke
RFI suppression choke
Chopper amplifiers
DC drives and stepper motor controls
Switching power supplies
References
General Product Information
Weblinks
Approvals, RoHS, CHINA-RoHS, e-Store, Distributor-Stock-Check
Technical Data
Rated voltage
Rated Current
Rated inductance
Power Operating Frequency
Terminal technic
Weight
to 600 VDC
0.45 - 7 A @ Ta 70 °C
0.02 - 5 mH, Tol. ±15%
up to 20 kHz
Wire leads
10 - 12 g
Isolation Voltage
Climatic Category
Allowable Operation Temp.
2 kV eff., winding to ambient
40/125/21 acc. to IEC 60068-1
-40 °C to 125 °C
Dimensions
a
b
c
Ød
Dimensions: see table of variants
EMC Products
DLO
Suppression Chokes
www.schurter.com/pg81_82
Diagrams
Application in DC-DC Converter
DLH/DLN/DLO
DS/DSO
DLH/DLN/DLO
1)
2)
1) DC-Input unregulated
2) DC-Output regulated
Derating Curves
Inductance variation as function of the magnetizing current
Variants
In [A]
Ln [mH]
Rcu
[mΩ]
fRES
[MHz]
Inductance
drop max [%]
A [mm]
B [mm]
C [mm]
D [mm]
Weight [g]
Packing unit [pcs.]
Order Number
0.45
5
3000
0.3
20
20
15
10
0.27
10
200
DLO1-24-0008
0.6
3
1550
0.4
20
20
36
10
0.32
11
200
DLO1-24-0007
1.0
1
600
0.8
20
20
15
10
0.38
10
200
DLO1-24-0006
1.5
0.5
280
1.3
20
20
15
10
0.48
10
200
DLO1-24-0005
1.8
0.3
178
2
20
20
15
10
0.55
10
200
DLO1-24-0004
3
0.1
70
8.2
20
20
36
10
0.65
10
200
DLO1-24-0003
4.5
0.05
26
8.4
20
20
15
10
0.9
11
200
DLO1-24-0002
7
0.02
12
20.2
20
20
36
10
1.2
12
200
DLO1-24-0001
Rcu at Tu 20°C
Inductance drop at In Derating at Tu >70°C: I = Inx ((125-Tu)/55)0.5
The
specifications,
descriptions and illustrations indicated in this document are based on
EMC
Products
current information. All content is subject to modifications and amendments.
Similar pages