Crydom CKRD2420 Din rail mount Datasheet

CKR24 Series
• Ratings from 10A to 30A @ 280 VAC
• Slim 22.5mm (width) package
• SCR output for heavy industrial loads
• LED input status indicator
• AC or DC control
• Zero-crossing (resistive loads) or random-fire (inductive loads) output
PRODUCT SELECTION
Description
4-32 VDC Control
90-280 VAC Control
18-36 VAC Control
10 A
20 A
30 A
CKRD2410
CKRA2410
CKRA2410E
CKRD2420
CKRA2420
CKRA2420E
CKRD2430
CKRA2430
CKRA2430E
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (1)
Description
10 A
20 A
30 A
Operating Voltage (47-63Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2)
Maximum Load Current [Arms]
Minimum Load Current [Arms]
Maximum Surge Current (16.6ms) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Maximum I² t for Fusing (8.3 msec) [A² sec]
Minimum Power Factor (with Maximum Load)
24-280
600
10
500
10
0.15
120
1.6
60
0.5
24-280
600
10
500
20
0.15
250
1.6
260
0.5
24-280
600
10
500
30
0.15
1200
1.6
6000
0.5
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Minimum Turn-On Voltage
Minimum Turn-Off Voltage
Typical Input Current (4)
Maximum Turn-On Time [msec] (3)
Maximum Turn-Off Time [msec]
CKRD24xx
CKRA24xx
CKRA24xxE
4.0-32 VDC
4.0 VDC
1.0 VDC
8-12 mA
1/2 Cycle
1/2 Cycle
90-280 Vrms
90 Vrms
10 Vrms
2 mA @ 120 Vrms, 4 mA @ 240 Vrms
10
40
18-36 Vrms
18 Vrms
4.0 Vrms
10 mA @ 240 Vrms
10
40
GENERAL SPECIFICATIONS
Description
Parameters
Dielectric Strength, Input/Output/Base (50/60Hz)
Minimum Insulation Resistance (@ 500 V DC)
109 Ohms
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Status Indicator Display
Weight (typical)
Encapsulation
Terminals
Maximum Wire Size:
Recommended Terminal Screw Torque Range:
Min. Side by Side Spacing
8 pF
-40ºC to 80ºC
-40ºC to 125ºC
Green LED
10 oz. (280g)
Thermally Conductive Epoxy
Box Clamp Type
AWG # 10 (3mm)
5.0-6.0 in lb (0.6-0.7 Nm)
0.8 inch (20mm)
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
3) Turn-on time for DC control random turn-on versions is 0.02 msec
4) Input circuitry for DC control version incorporates active current limiter.
WIRING DIAGRAM
4000Vrms
MECHANICAL SPECIFICATIONS
THERMAL DERATE INFORMATION
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314
E116950
LR81689
129156ÜG
Rev. 062212
ANNEX - ENVIROMENTAL INFORMATION
Similar pages