Skyworks EVB1212 Aca1212: 1.2 ghz catv line amplifier mmic Datasheet

DATA SHEET
ACA1212: 1.2 GHz CATV Line Amplifier MMIC
Applications
 50 to 1218 MHz 75 Ω amplifier
 HFC distribution systems
 CATV head-end equipment
 CATV line amplifier
Features
 50 to 1218 MHz frequency range
 Flat gain
 Very low distortion
 Excellent input/output match
 Low DC power consumption
 Single 12 V supply
Description
 Surface-mount package compatible with automatic assembly
The ACA1212 is a highly linear, high output power integrated RF
amplifier designed for CATV head ends and HFC distribution
systems. The IC consists of two parallel amplifiers cascaded
between transmission line baluns that are optimized for
exceptionally low distortion, high output power, and high crash
point in a thermally enhanced surface-mount package. The
ACA1212 covers the full 50 to 1218 MHz CATV downstream band
demanded by DOCSIS 3.1 systems.
 Repeatability of monolithic fabrication
 RoHS-compliant packaging
 Highly reliable GaAs MESFET technology
Skyworks GreenTM products are compliant with
all applicable legislation and are halogen-free.
For additional information, refer to Skyworks
Definition of GreenTM, document number
SQ04–0074.
RF Input
A block diagram of the ACA1212 is shown in Figure 1. The device
package and pinout are shown in Figure 2. Signal pin
assignments and functional pin descriptions are described in
Table 1.
12 dB
RF Output
12 dB
204202-001
Figure 1. ACA1212 Block Diagram
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
204202C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 13, 2017
1
DATA SHEET • ACA1212: 1.2 GHz CATV LINE AMPLIFIER MMIC
1
GND
GND
16
2
N/C
N/C
15
3
RFINA
RFOUTA
14
4
GND
GND
13
5
GND
GND
12
6
RFINB
RFOUTB
11
7
IADJ
N/C
10
8
GND
GND
9
204202-002
Figure 2. ACA1212 Pinout
(Top View)
Table 1. AWB7124 Signal Pin Descriptions1
Pin
Name
Description
Pin
Name
Description
1
GND
Ground
9
GND
Ground
2
N/C
No connection
10
N/C
No connection
3
RFINA
Input to Amplifier A
11
RFOUTB
Output from Amplifier B
4
GND
Ground
12
GND
Ground
5
GND
Ground
13
GND
Ground
6
RFINB
Input to Amplifier B
14
RFOUTA
Output from Amplifier A
7
IADJ
Current adjust
15
N/C
No connection
8
GND
Ground
16
GND
Ground
1 The center ground pad must have a low inductance and low thermal resistance connection to the application’s printed circuit board ground plane.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
March 13, 2017 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 204202C
DATA SHEET • ACA1212: 1.2 GHz CATV LINE AMPLIFIER MMIC
Electrical and Mechanical Specifications
The absolute maximum ratings of the ACA1212 are provided in
Table 2. Recommended operating conditions are specified in
Table 3, and electrical specifications are provided in Table 4.
Table 2. ACA1212 Absolute Maximum Ratings1
Parameter
Minimum
Maximum
Units
Amplifier supplies (pins 11 and 14)
0
+15
VDC
RF input power (pins 3 and 6)
-
+70
dBmV
Storage temperature
–6 5
+150
°C
Soldering temperature
-
+260
°C
Soldering time
-
5.0
sec
1 Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters set at
or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
2 Pins 3 and 6 should be AC-coupled. No external DC bias should be applied.
ESD HANDLING: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device.
This device must be protected at all times from ESD when handling or transporting. Static charges may easily produce
potentials of several kilovolts on the human body or equipment, which can discharge without detection.
Industry-standard ESD handling precautions should be used at all times.
Table 3. ACA1212 Recommended Operating Conditions1
Parameter
Symbol
RF frequency
f
Supply (pins 11 and 14)
VDD
Operating temperature
TA
Min
Typ
50
Max
Units
1218
MHz
+12
VDC
–40
+100
°C
1 Performance is guaranteed only under the conditions listed in this table.
Table 4. ACA1212 Electrical Specifications1
TA = +25 C, VDD = +12 VDC, Unless Otherwise Noted)
Parameter
Gain1
Symbol
G
Gain flatness1
Test Condition
1218 MHz
Min
Typ
Max
Units
10.3
10.9
11.5
dB
55.25 MHz to 1218 MHz
Cable equivalent slope1
± 0.3
-0.5
dB
0.25
1.0
dB
4
4.5
dB
Noise figure1
NF
CTB1,2
CTB
–72
–70
dBc
CSO1,2
CSO
–70
–68
dBc
XMOD1,2
ACLR
–67
Supply current
395
Return loss (input/output)1
RL
Thermal resistance
θJC
55.25 MHz to 1218 MHz
18
dBc
445
22
mA
dB
6.0
°C/W
1 Measured with a balun on input and output of the device. See Figure 3 for test setup.
2 Device measured with 79 analog channels, +47 dBmV output power at 1000 MHz with a 3 dB tilt and QAM to 1000 MHz.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
204202C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 13, 2017
3
DATA SHEET • ACA1212: 1.2 GHz CATV LINE AMPLIFIER MMIC
Evaluation Board Description
The ACA1212 Evaluation Board is used to test the performance of
the ACA1212 device. An Evaluation Board schematic is provided
in Figure 3. Table 6 provides the Bill of Materials (BOM) list for
Evaluation Board components.
+12 VDC (vdd )
0.01 uF
1
2
3
4
5
6
7
8
MABA -009210 -CT 1760
1.2nH
RFIN
0.01 uF
0.8pF
0.01 uF
68 .1K
+12 VDC (VDD)
GND
N/C
RFIN1
GND
GND
RFIN2
IADJ
GND
GND
N/C
RFOUT1
GND
GND
RFOUT2
N/C
GND
16
15
14
13
12
11
10
9
204202-003
0.01 uF
470 nH
47 uF
MABA -009210 -CT 1760
1.0nH
RFOUT
270 pF
0.1pF
270 pF
470 nH
+12 VDC (VDD)
0.01 uF
Figure 3. ACA1212 Evaluation Board Schematic
Table 6. ACA1212 Evaluation Board Bill of Materials (BOM)
Component
Description
Manufacturer
Mfr Part Number
L1
1.2 nH inductor (0402)
Murata
LQG15HS1N2S02D
T1, T2
1:1 transmission line balun
Macom
MABA- 009210-CT1760
C1, C2, C4, C6, C8
0.01 uF capacitor (0603)
Murata
GRM188R71H- 103KA01D
C3
0.8 pF (0402)
Murata
GRM- 1555C1HR80RZ01D
R1
68.1 k Ω (0402)
Rohm
MCR01MRTF6802
L2, L3
470 nH (0805)
Murata
LQH31CNR47M03L
C5
0.1 pF (0402)
Murata
GJM- 1555C1HR10WB01D
C9, C10
270 pF (0603)
Murata
GRM1885C1H- 271JA01D
L4
1.0 nH (0402)
Murata
LQG15HS1N0S02D
C7
47 uF electrolytic cap
Panasonic
ECEA1HGE470
CON1-2
75 Ω N bulkhead
Paternack
PE4504
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
March 13, 2017 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 204202C
DATA SHEET • ACA1212: 1.2 GHz CATV LINE AMPLIFIER MMIC
Package Dimensions
Package and Handling Information
The PCB layout footprint drawing for the ACA1212 is shown in
Figure 4. The package dimensions for the ACA1212 are shown in
Figure 5. The tape and reel dimensions are provided in Figure 6.
Since the device package is sensitive to moisture absorption, it is
baked and vacuum packed before shipping. Instructions on the
shipping container label regarding exposure to moisture after the
container seal is broken must be followed. Otherwise, problems
related to moisture absorption may occur when the part is
subjected to high temperature during solder assembly.
The ACA1212 is rated to Moisture Sensitivity Level 2 (MSL2) at
260 C. It can be used for lead or lead-free soldering. For
additional information, refer to the Skyworks Application Note,
Solder Reflow Information, document number 200164.
Care must be taken when attaching this product, whether it is
done manually or in a production solder reflow environment.
Production quantities of this product are shipped in a standard
tape and reel format.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
204202C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 13, 2017
5
PRELIMINARY DATA SHEET • ACA1212: 1.2 GHz CATV LINE AMPLIFIER MMIC
Figure 4. ACA1212 PCB Layout Footprint Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
March 13, 2017 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 204202C
DATA SHEET • ACA1212: 1.2 GHz CATV LINE AMPLIFIER MMIC
Figure 5. ACA1212 Package Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
204202C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 13, 2017
7
DATA SHEET • ACA1212: 1.2 GHz CATV LINE AMPLIFIER MMIC
204202-006
Figure 6. ACA1212 Tape and Reel Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
8
March 13, 2017 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 204202C
DATA SHEET • ACA1212: 1.2 GHz CATV LINE AMPLIFIER MMIC
Ordering Information
Model Number
ACA1212P2
Package Description
16-pin wide body SOIC with heat slug
EVB1212
Component Packaging
1500-piece tape and reel
Evaluation Board part number
Copyright © 2017 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by
Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions
of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks and the Skyworks symbol are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for
identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by
reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
204202C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 13, 2017
9
Similar pages