Dallas DS2417V 1-wire time chip with interrupt Datasheet

PRELIMINARY
TM
1-Wire
DS2417
Time Chip With Interrupt
www.dalsemi.com
PIN ASSIGNMENT
FEATURES
§ Real-Time Clock with fully compatible
1-Wire MicroLAN interface
§ Uses the same binary time/date representation
as the DS2404 but with 1 second resolution
§ Clock accuracy ± 2 minutes per month
at 25°C
§ Programmable interrupt output for system
wakeup
§ Communicates at 16.3k bits per second
§ Unique, factory-lasered and tested 64-bit registration number (8-bit family code + 48-bit
serial number + 8-bit CRC tester) assures absolute traceability because no two parts are
alike
§ 8-bit family code specifies device communication requirements to bus master
§ Built-in multidrop controller ensures compatibility with other MicroLAN products
§ Operates over a wide VDD voltage range of
2.5V to 5.5V from -40°C to +85°C
§ Low power, 200 nA typically with oscillator
running
§ Compact, low cost 6-pin TSOC surface
mount package
6-PIN TSOC PACKAGE
1
2
3
6
5
4
TOP VIEW
SIDE VIEW
See Mech. Drawings
Section
PIN DESCRIPTION
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
GND
1-Wire
INT
VDD
X1
X2
ORDERING INFORMATION
DS2417P 6-pin TSOC package
DS2417V Tape & Reel of DS2417P
DS2417X Chip Scale Pkg., Tape & Reel
DESCRIPTION
The DS2417 1-Wire Time Chip with Interrupt offers a simple solution for storing and retrieving vital
time information with minimal hardware. The DS2417 contains a unique lasered ROM and a real-time
clock/calendar implemented as a binary counter. Only one pin is required for communication with the
device. Utilizing a backup energy source, the data is nonvolatile and allows for stand-alone operation.
The DS2417 features can be used to add functions such as calendar, time and date stamp, and logbook to
any type of electronic device or embedded application that uses a microcontroller.
OVERVIEW
The DS2417 has two main data components: 1) 64-bit lasered ROM, and 2) real-time clock counter
(Figure 1). The real-time clock utilizes an on-chip oscillator that is connected to an external 32.768 kHz
crystal. The hierarchical structure of the 1-Wire protocol is shown in Figure 2. The bus master must first
provide one of four ROM function commands: 1) Read ROM, 2) Match ROM, 3) Search ROM, 4) Skip
ROM. The protocol for these ROM functions is described in Figure 7. After a ROM function command
1 of 15
062299
DS2417
is successfully executed, the real-time clock functions become accessible and the master may then
provide one of the real-time clock function commands. The protocol for these commands is described in
Figure 5. All data is read and written least significant bit first.
DETAILED PIN DESCRIPTION
PIN
1
2
3
4
5, 6
SYMBOL
GND
1-Wire
INT
VDD
X1, X2
DESCRIPTION
Ground Pin
Data input/output Open drain.
Interrupt pin Open drain.
Power input pin. 2.5V to 5.5V.
Crystal pins. Connections for a standard 32.768 kHz quartz crystal, EPSON
part number C-002RX or C-004R (be sure to request 6 pF load capacitance).
NOTE: X1 and X2 are very high impedance nodes. It is recommended that they
and the crystal be guard-ringed with ground and that high frequency signals be
kept away from the crystal area. See Figure 10 and Application Note 58 for details.
BLOCK DIAGRAM Figure 1
1-WIRE
ROM
FUNCTION
CONTROL
64-BIT
LASERED
ROM
CLOCK
FUNCTION
CONTROL
INT\
INT
READ/WRITE BUFFER
INT. GENERATOR
RTC COUNTER (32-BIT)
VDD
OSCILLATOR
CONTROL
32.768 kHz
OSC./DIVIDER
X1
1 Hz
X2
64-BIT LASERED ROM
Each DS2417 contains a unique ROM code that is 64 bits long. The first eight bits are a 1-Wire family
code. The next 48 bits are a unique serial number. The last eight bits are a CRC of the first 56 bits. (See
Figure 3.) The 1-Wire CRC is generated using a polynomial generator consisting of a shift register and
XOR gates as shown in Figure 4. The polynomial is X8 + X5 + X4 + 1. Additional information about the
Dallas Semiconductor 1-Wire Cyclic Redundancy Check is available in the Book of DS19xx iButton
Standards. The shift register bits are initialized to zero. Then starting with the least significant bit of the
family code, one bit at a time is shifted in. After the 8th bit of the family code has been entered, then the
serial number is entered. After the 48th bit of the serial number has been entered, the shift register
contains the CRC value. Shifting in the eight bits of CRC should return the shift register to all zeros. The
2 of 15
DS2417
64-bit ROM and ROM Function Control section allow the DS2417 to operate as a 1-Wire device and
follow the 1-Wire protocol detailed in the section "1-Wire Bus System".
HIERARCHICAL STRUCTURE FOR 1-WIRE PROTOCOL Figure 2
1-Wire Bus
Bus
Master
Other
Devices
DS2417
Command
Level
1-Wire ROM Function
Commands (see Figure 7)
DS2417 specific
Function Commands
(see Figure 5)
Available
Commands
Data Fields
Affected
Read ROM
Match ROM
Search ROM
Skip ROM
64-bit ROM
64-bit ROM
64-bit ROM
N/A
Write Clock
Read Clock
RTC Counter, Device Control
RTC Counter, Device Control
64-BIT LASERED ROM Figure 3
MSB
LSB
8-Bit CRC Code
MSB
48-Bit Serial Number
LSB
MSB
8-Bit Family Code (27h)
LSB
MSB
LSB
1-WIRE CRC GENERATOR Figure 4
Polynomial = X 8 + X 5 + X 4 + 1
R
1ST
STAGE
X0
2ND
STAGE
X1
X2
3RD
STAGE
4TH
STAGE
X3
5TH
STAGE
X4
S
6TH
STAGE
X5
X6
7TH
STAGE
8TH
STAGE
X7
INPUT DATA
3 of 15
X8
DS2417
TIMEKEEPING
A 32.768 kHz crystal oscillator is used as the time base for the real-time clock counter. The oscillator can
be turned on or off under software control. The oscillator must be on for the real time clock to function.
The real-time clock counter is double buffered. This allows the master to read time without the data
changing while it is being read. To accomplish this, a snapshot of the counter data is transferred to a
read/write buffer, which the user accesses.
DEVICE CONTROL BYTE
The DS2417 can generate interrupt pulses to trigger activities that have to occur at regular intervals. The
selection of this interval and the on/off control of the 32.768 kHz crystal oscillator are done through the
device control byte. This byte can be read and written through the Clock Function commands.
Device Control Byte
7
6
5
IE
IS2
IS1
Bit 0 - 1
0
4
IS0
3
OSC
2
OSC
1
0
0
0
No function
Bits 0 and 1 are hard-wired to read all 0’s.
Bit 2 - 3 OSC Oscillator Enable/Disable
These bits control/report whether the 32.768 kHz crystal oscillator is running. If the oscillator is running,
both OSC bits will read 1. If the oscillator is turned off these bits will all read 0. When writing the
device control byte both occurrences of the OSC bit should have identical data. Otherwise the value in
bit address 3 (bold) takes precedence.
IS
Interval Select
Bit 4 - 6
These bits determine the time between interrupt pulses. The values available are shown below.
IS2
IS1
IS0
Interrupt Interval
0
0
0
1s
0
0
1
4s
0
1
0
32s
= 0.53 min
0
1
1
64s
= 1.07 min
1
0
0
2048s = 34.13 min
1
0
1
4096s = 68.27 min
1
1
0
65536s = 18.20 hours
1
1
1
131072s = 36.41 hours
Bit 7
IE Interrupt Enable
This bit controls whether the interrupt pulse will be generated at the selected interval.
interrupts this bit needs to be 1.
4 of 15
To enable
DS2417
REAL-TIME CLOCK
The real-time clock is a 32-bit binary counter. It is incremented once per second. The real-time clock
can accumulate 136 years of seconds before rolling over. Time/date is represented by the number of
seconds since a reference point, which is determined by the user. For example, 12:00 a.m., January 1,
1970 could be a reference point.
CLOCK FUNCTION COMMANDS
The “Clock Function Flow Chart” (Figure 5) describes the protocols necessary for accessing the real-time
clock. With only four bytes of real-time clock and one control byte the DS2417 does not provide random
access. Reading and writing always starts with the device control byte followed by the least significant
byte of the time data.
READ CLOCK [66h]
The read clock command is used to read the device control byte and the contents of the real-time clock
counter. After having received the most significant bit of the command code the device copies the actual
contents of the real-time clock counter to the read/write buffer. Now the bus master reads data beginning
with the device control byte followed by the least significant byte through the most significant byte of the
real-time clock. After this the bus master may continue reading from the DS2417. The data received will
be the same as in the first pass through the command flow. The read clock command can be ended at any
point by issuing a Reset Pulse.
WRITE CLOCK [99h]
The write clock command is used to set the real-time clock counter and to write the device control byte.
After issuing the command, the bus master writes first the device control byte, which becomes immediately effective. After this the bus master sends the least significant byte through the most significant byte
to be written to the real-time clock counter. The new time data is copied from the read/write buffer to the
real-time clock counter and becomes effective as the bus master generates a reset pulse. If enabled, an
interrupt pulse will be generated either immediately or delayed, depending on the actual time and the selected interval duration (see Figure 11). If the oscillator is intentionally stopped the real-time clock counter behaves as a four-byte non-volatile memory.
5 of 15
DS2417
CLOCK FUNCTION COMMAND FLOW CHART Figure 5
Master TX Control
Function Command
66H
Read Clock
?
Y
DS2417 copies
RTC Counter
to R/W Buffer
99H
Write Clock
?
Y
N
N
Bus Master TX
Device Control Byte
Bus Master RX
Device Control Byte
Bus Master TX
LS Byte (7:0)
Bus Master RX
LS Byte (7:0)
Bus Master TX
next Byte (15:8)
Bus Master RX
next Byte (15:8)
Bus Master TX
next Byte (23:16)
Bus Master RX
next Byte (23:16)
Bus Master TX
MS Byte (31:24)
Bus Master RX
MS Byte (31:24)
N
N
Bus Master
TX Reset
?
Y
Bus Master
TX Reset
?
Y
DS2417 copies
R/W Buffer
to RTC Counter
DS2417 TX
Presence Pulse
6 of 15
N
Bus Master
TX Reset
?
Y
DS2417
HARDWARE CONFIGURATION Figure 6
BUS MASTER
Open Drain
Port Pin
VPUP
DS2417 1-WIRE PORT
5 kΩ
Typ.
DATA
RX
TX
TX
RX = RECEIVE
TX = TRANSMIT
RX
5 µA
Typ.
100 Ω
MOSFET
1-WIRE BUS SYSTEM
The 1-Wire bus is a system, which has a single bus master and one or more slaves. In all instances the
DS2417 is a slave device. The bus master is typically a microcontroller. The discussion of this bus
system is broken down into three topics: hardware configuration, transaction sequence, and 1-Wire
signaling (signal types and timing). A 1-Wire protocol defines bus transactions in terms of the bus state
during specified time slots that are initiated on the falling edge of sync pulses from the bus master. For a
more detailed protocol description, refer to Chapter 4 of the Book of DS19xx iButton Standards.
HARDWARE CONFIGURATION
The 1-Wire bus has only a single line by definition; it is important that each device on the bus be able to
drive it at the appropriate time. To facilitate this, each device attached to the 1-Wire bus must have open
drain or 3-state outputs. The 1-Wire input of the DS2417 is open drain with an internal circuit equivalent
to that shown in Figure 6. A multidrop bus consists of a 1-Wire bus with multiple slaves attached. The
1-Wire bus has a maximum data rate of 16.3k bits per second and requires a pullup resistor of approximately 5kΩ .
The idle state for the 1-Wire bus is high. If for any reason a transaction needs to be suspended, the bus
MUST be left in the idle state if the transaction is to resume. If this does not occur and the bus is left low
for more than 120 µs, one or more of the devices on the bus may be reset. Since the DS2417 gets all its
energy for operation through its VDD pin it will NOT perform a power-on reset if the 1-Wire bus is low
for an extended time period.
TRANSACTION SEQUENCE
The protocol for accessing the DS2417 via the 1-Wire port is as follows:
§ Initialization
§ ROM Function Command
§ Clock Function Command
7 of 15
DS2417
INITIALIZATION
All transactions on the 1-Wire bus begin with an initialization sequence. The initialization sequence consists of a reset pulse transmitted by the bus master followed by presence pulse(s) transmitted by the
slave(s). The presence pulse lets the bus master know that the DS2417 is on the bus and is ready to
operate. For more details, see the “1-Wire Signaling” section.
ROM FUNCTION COMMANDS
Once the bus master has detected a presence, it can issue one of the four ROM function commands that
the DS2417 supports. All ROM function commands are eight bits long. A list of these commands
follows (refer to flowchart in Figure 7):
Read ROM [33h]
This command allows the bus master to read the DS2417’s 8-bit family code, unique 48-bit serial number, and 8-bit CRC. This command should only be used if there is a single slave on the bus. If more than
one slave is present on the bus, a data collision will occur when all slaves try to transmit at the same time
(open drain will produce a wired-AND result). The resultant family code and 48-bit serial number read
by the master will be invalid.
Match ROM [55h]
The match ROM command, followed by a 64-bit ROM sequence, allows the bus master to address a specific DS2417 on a multidrop bus. Only the DS2417 that exactly matches the 64-bit ROM sequence will
respond to the following clock function command. All slaves that do not match the 64-bit ROM
sequence will wait for a reset pulse. This command can be used with a single or multiple devices on the
bus.
SEARCH ROM [F0h]
When a system is initially brought up, the bus master might not know the number of devices on the 1Wire bus or their 64-bit ROM codes. The search ROM command allows the bus master to use a process
of elimination to identify the 64-bit ROM codes of all slave devices on the bus. The search ROM process
is the repetition of a simple 3-step routine: read a bit, read the complement of the bit, then write the desired value of that bit. The bus master performs this 3-step routine on each bit of the ROM. After one
complete pass, the bus master knows the 64-bit ROM code of one device. Additional passes will identify
the ROM codes of the remaining devices. See Chapter 5 of the Book of DS19xx iButton Standards for a
comprehensive discussion of a search ROM, including an actual example.
Skip ROM [CCh]
This command can save time in a single drop bus system by allowing the bus master to access the clock
functions without providing the 64-bit ROM code. If more than one slave is present on the bus and, for
example, a read command is issued following the Skip ROM command, data collision will occur on the
bus as multiple slaves transmit simultaneously (open drain pulldowns will produce a wired-AND result).
8 of 15
DS2417
ROM FUNCTIONS FLOW CHART Figure 7
Master TX
Reset Pulse
DS2417 TX
Presence Pulse
Master TX ROM
Function Command
33H
Read ROM
Command
?
Y
DS2417 TX
Family Code
1 Byte
N
55H
Match ROM
Command
?
F0H
Search ROM
Command
?
Y
N
Y
DS2417 TX Bit 0
Master TX Bit 0
DS2417 TX Bit 0
Master TX Bit 0
Bit 0
Match ?
N
N
Bit 0
Match ?
Y
Y
DS2417 TX
Serial Number
6 Bytes
DS2417 TX Bit 1
Master TX Bit 1
Bit 1
Match ?
N
DS2417 TX Bit 1
Master TX Bit 1
N
Bit 1
Match ?
Y
Y
DS2417 TX Bit 63
DS2417 TX
CRC Byte
Master TX Bit 63
DS2417 TX Bit 63
Master TX Bit 63
Bit 63
Match ?
N
N
Bit 63
Match ?
Y
Y
Master TX Control
Function Command
(SEE FIGURE 5)
9 of 15
N
CCH
Skip ROM
Command
?
Y
N
DS2417
1–WIRE SIGNALING
The DS2417 requires strict protocols to ensure data integrity. The protocol consists of four types of signaling on one line: Reset Sequence with Reset Pulse and Presence Pulse, Write 0, Write 1 and Read Data.
Except for the presence pulse the bus master initiates all these signals.
The initialization sequence required to begin any communication with the DS2417 is shown in Figure 8.
A reset pulse followed by a presence pulse indicates the DS2417 is ready to send or receive data. The bus
master transmits (TX) a reset pulse (tRSTL, minimum 480 µs). The bus master then releases the line and
goes into receive mode (RX). The 1-Wire bus is pulled to a high state via the pullup resistor. After
detecting the rising edge on the data line, the DS2417 waits (tPDH, 15-60 µs) and then transmits the
presence pulse (tPDL, 60-240 µs).
INITIALIZATION PROCEDURE “RESET AND PRESENCE PULSES” Figure 8
MASTER TX
"RESET PULSE"
MASTER RX "PRESENCE PULSE"
tRSTH
VPULLUP
VPULLUP MIN
VIH MIN
VIL MAX
0V
tRSTL
RESISTOR
MASTER
DS2417
*
**
tR
tPDH
tPDL
480 µs ≤ tRSTL < ∞ *
480 µs ≤ tRSTH < ∞ **
15 µs ≤ tPDH < 60 µs
60 ≤ tPDL < 240 µs
In order not to mask interrupt signaling by other devices on the 1-Wire bus tRSTL + tR should always be less than 960 µs.
Includes recovery time
READ/WRITE TIME SLOTS
The definitions of write and read time slots are illustrated in Figure 9. The master initiates all time slots
by driving the data line low. The falling edge of the data line synchronizes the DS2417 to the master by
triggering an internal delay circuit. During write time slots, the delay circuit determines when the
DS2417 will sample the data line. For a read data time slot, if a “0” is to be transmitted, the delay circuit
determines how long the DS2417 will hold the data line low. If the data bit is a “1”, the DS2417 will not
hold the data line low at all.
10 of 15
DS2417
READ/WRITE TIMING DIAGRAM Figure 9
Write-one Time Slot
tSLOT
VPULLUP
tREC
VPULLUP MIN
VIH MIN
DS2417
Sampling Window
VIL MAX
0V
tLOW1
15µs
(OD: 2µs)
60µs
RESISTOR
MASTER
(OD: 6µs)
60 µs ≤ tSLOT < 120 µs
1 µs ≤ tLOW1 < 15 µs
1 µs ≤ tREC < ∞
Write-zero Time Slot
tSLOT
VPULLUP
VPULLUP MIN
VIH MIN
DS2417
Sampling Window
VIL MAX
0V
15µs
(OD: 2µs)
RESISTOR
MASTER
(OD: 6µs)
60µs
t LOW0
60 µs ≤ tLOW0 < tSLOT < 120 µs
1 µs ≤ tREC < ∞
11 of 15
tREC
DS2417
READ/WRITE TIMING DIAGRAM (continued) Figure 9
Read-data Time Slot
tREC
tSLOT
VPULLUP
VPULLUP MIN
VIH MIN
Master
Sampling Window
VIL MAX
0V
tSU
tRELEASE
tLOWR
tRDV
60 µs ≤ tSLOT < 120 µs
1 µs ≤ tLOWR < 15 µs
0 ≤ tRELEASE < 45 µs
RESISTOR
1 µs ≤ tREC < ∞
tRDV = 15 µs
tSU < 1 µs
MASTER
DS2417
CRYSTAL PLACEMENT ON PCB Figure 10
LOCAL GROUND
PLANE BENEATH
SIGNAL PLANE
OR ON OTHER
SIDE OF PCB
GND
X1
CRYSTAL
PADS
1-Wire
INT
INT\
X2
VDD
GUARD RING
ON SIGNAL
PLANE
12 of 15
DS2417
INTERRUPT TIMING Figure 11
VINT
Case A: Latency < 0.5 t INTERVAL
t LATENCY
VINT
t INTERVAL
t PULSE = 122 µs Time
Case B: 0 < Latency < t INTERVAL
t LATENCY
t INTERVAL
t PULSE = 122 µs Time
The latency depends on the selected interrupt interval (IS0 to IS2 settings) and the contents of the RTC
counter at the time of writing the device control byte. In Case A, the flip-flop that determines the interval
duration is reset and toggles before half of the interval time is over. In Case B, this flip-flop is set which
generates an immediate interrupt pulse; the latency, therefore, can be up to one full interval duration.
If enabled, the interrupt pulse may also be triggered while reading from or writing to the control byte.
13 of 15
DS2417
ABSOLUTE MAXIMUM RATINGS*
Voltage on 1-Wire to Ground
Operating Temperature
Storage Temperature
Soldering Temperature
-0.5V to +7.0V
-40°C to +85°C
-55°C to +125°C
260°C for 10 seconds
* This is a stress rating only and functional operation of the device at these or any other conditions
above those indicated in the operation sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods of time may affect reliability.
DC ELECTRICAL CHARACTERISTICS
(VPUP=2.5V to 6.0V; VDD = 2.5V to 5.5V, -40°C to +85°C)
PARAMETER
Logic 1
Logic 0
Output Logic Low @ 4 mA
Output Logic High
Input Load Current
Interrupt Sink Current
@ 0.4V
Operating Current (Osc. On)
Quiescent Current (Osc. Off)
Interrupt Sink Current
@ 0.4V
Operating Current (Osc. On)
Quiescent Current (Osc. Off)
SYMBOL
VIH1
VIL1
VOL1
VOH1
IL1
IINT3
IDD3
IDDQ3
IINT5
MIN
2.2
-0.3
TYP
MAX
6.0
TBD
0.4
VPUP
UNITS
V
V
V
V
µA
mA
NOTES
1,11
1,6
1
1,3
4
9
250
50
nA
nA
mA
2, 9
2, 8, 9
10
450
100
nA
nA
2, 10
2, 8, 10
5
5
10
IDD5
IDDQ5
CAPACITANCE
PARAMETER
Capacitance 1-Wire
(TA = 25°C)
SYMBOL
CIN
MIN
TYP
MAX
50
UNITS
pF
NOTES
AC ELECTRICAL CHARACTERISTICS
(VPUP=2.5V to 6.0V; VDD = 2.5V to 5.5V, -40°C to +85°C)
PARAMETER
Time Slot
Write 1 Low Time
Write 0 Low Time
Read Low Time
Read Data Valid
Release Time
Read Data Setup
Recovery Time
Reset High Time
Reset Low Time
Presence Detect High
Presence Detect Low
SYMBOL
tSLOT
tLOW1
tLOW0
tLOWR
tRDV
tRELEASE
tSU
tREC
tRSTH
tRSTL
tPDH
tPDL
MIN
60
1
60
1
0
1
480
480
15
60
14 of 15
TYP
exactly 15
15
MAX
120
15
120
15
45
1
960
60
240
UNITS
µs
µs
µs
µs
µs
µs
µs
µs
µs
µs
µs
µs
NOTES
12
5
7
DS2417
NOTES:
1. All voltages are referenced to ground.
2. Measured with outputs open.
3. VPUP = external pullup voltage.
4. Input load is to ground.
5. Read data setup time refers to the time the host must pull the 1-Wire bus low to read a bit. Data is
guaranteed to be valid within 1 µs of this falling edge.
6. Under certain low voltage conditions VIL1MAX may have to be reduced to as much as 0.5V to always
guarantee a presence pulse.
7. The reset low time (tRSTL) should be restricted to a maximum of 960 µs, to allow interrupt signaling,
otherwise, it could mask or conceal interrupt pulses.
8. When VDD ramps up, the oscillator is always off.
9. At VDD = 3V ± 10%
10. At VDD = 5V ± 10%
11. VIH1 has to be VDD – 0.3V or higher.
12. The master must read while the data is valid.
15 of 15