HRPG-300 300W Single Output with PFC Function series ■ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ Bauar t gepruft Sicherheit egel ma ge od o s be wac g www. tuv.com ID 2000000000 SPECIFICATION MODEL OUTPUT HRPG-300-3.3 HRPG-300-5 HRPG-300-7.5 HRPG-300-12 HRPG-300-15 HRPG-300-24 HRPG-300-36 HRPG-300-48 DC VOLTAGE 3.3V 5V 7.5V 12V 15V 24V 36V 48V RATED CURRENT 60A 60A 40A 27A 22A 14A 9A 7A CURRENT RANGE 0 ~ 60A 0 ~ 60A 0 ~ 40A 0 ~ 27A 0 ~ 22A 0 ~ 14A 0 ~ 9A 0 ~ 7A RATED POWER 198W 300W 300W 324W 330W 336W 324W 336W RIPPLE & NOISE (max.) Note.2 80mVp-p 90mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p 250mVp-p 250mVp-p VOLTAGE ADJ. RANGE 4.3 ~ 5.8V ±2.0% 6.8 ~ 9V ±2.0% 10.2 ~ 13.8V ±1.0% 13.5 ~ 18V ±1.0% 21.6 ~ 28.8V ±1.0% 28.8 ~ 39.6V ±1.0% 40.8 ~ 55.2V ±1.0% 2.8 ~ 3.8V VOLTAGE TOLERANCE Note.3 ±2.5% LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.3% ±0.3% ±0.2% ±0.2% ±0.2% LOAD REGULATION ±1.0% ±1.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% SETUP, RISE TIME 1000ms, 50ms/230VAC HOLD UP TIME (Typ.) 16ms/230VAC 87% 88% 89% 16ms/115VAC at full load VOLTAGE RANGE Note.5 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz INPUT PROTECTION FUNCTION 120 ~ 370VDC POWER FACTOR (Typ.) PF>0.95/230VAC EFFICIENCY (Typ.) 80% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 3.5A/115VAC 35A/115VAC LEAKAGE CURRENT <1.2mA / 240VAC OVERLOAD OVER VOLTAGE 2500ms, 50ms/115VAC at full load PF>0.99/115VAC at full load 82% 86% 88% 88% 1.8A/230VAC 70A/230VAC 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 41.4 ~ 48.6V 3.96 ~ 4.62V 57.6 ~ 67.2V Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE 5V STANDBY Shut down o/p voltage, recovers automatically after temperature goes down 5VSB : [email protected] ; tolerance±5%, ripple : 50mVp-p(max.) DC OK SIGNAL PSU turns on : 3.3 ~ 5.6V ; PSU turns off : 0 ~ 1V REMOTE CONTROL RC+ / RC-: 4 ~ 10V or open = power on ; 0 ~ 0.8V or short = power off FAN CONTROL (Typ.) Load 35±15% or RTH2≧50℃ Fan on WORKING TEMP. -40 ~ +70℃ (Refer to "Derating Curve") 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃) VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 4) EMC EMISSION OTHERS I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A MTBF 176K hrs min. DIMENSION 199*105*41mm (L*W*H) 0.95Kg;15pcs/15.3Kg/0.69CUFT PACKING NOTE UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC MIL-HDBK-217F (25℃) ℃ File Name:HRPG-300-SPEC 2017-07-14 HRPG-300 300W Single Output with PFC Function Mechanical Specification Unit:mm 18 12.5 Case No.980A series 4-M4 L=6 12.25 168.5 199 12.25 168.5 120 42.5 1 Pin No. Assignment 4,5 DC OUTPUT -V 6,7 DC OUTPUT +V 3 4 FAN 5 6 7 LED CN100 SVR Terminal HRS DF11-**SC or equivalent 167.5 12.25 167.5 12.25 17max. 12.5 18 41 HRS DF11-8DS or equivalent 4-M4 L=6 PWM fosc : 70KHz Block Diagram ACTIVE INRUSH CURRENT LIMITING EMI FILTER I/P Air flow direction 15 1 7 Mating Housing 2 8 Connector Pin No. Assignment (CN100) : HRS DF11-8DP-2DS or equivalent Pin No. Assignment AUX 1 AUXG 2 DC-OK 3 RC4 GND 5 RC+ 6 +S 7 -S 8 4-M4 L=5 2 75 105 125 Assignment AC/L AC/N FG 9.2 Pin No. 1 2 3 11 Terminal Pin No. Assignment AUX POWER RECTIFIERS & FILTER AUX AUXG +S RECTIFIERS & PFC POWER SWITCHING RECTIFIERS & FILTER +V -V O.T.P. O.L.P. -S DC-OK DETECTION CIRCUIT FG PFC CONTROL O.V.P. PWM CONTROL RC+ REMOTE CONTROL Derating Curve RC- Output Derating VS Input Voltage 100 100 90 80 80 70 50 40 LOAD(%) LOAD (%) 60 The 5V standby must be connected with a minimum load of 0.03A. 20 -40 -20 10 20 30 40 50 AMBIENT TEMPERATURE (℃) 60 70 (HORIZONTAL) 60 50 40 85 100 125 135 155 264 INPUT VOLTAGE (V) 60Hz File Name:HRPG-300-SPEC 2017-07-14 HRPG-300 300W Single Output with PFC Function series Function Description of CN100 Pin No. Function Description Auxiliary voltage output, 4.75~5.25V, reference to pin 2(AUXG). The maximum load current is 0.3A. This output is not controlled by the 1 AUX "remote ON/OFF control". Auxiliary voltage output ground. The signal return is isolated from the output terminals (+V & -V). DC-OK signal is a TTL level signal, referenced to pin5(DC-OK GND). High when PSU turns on. 2 3 4 5 6 AUXG DC-OK RCGND RC+ 7 +S Remote control ground. This pin connects to the negative terminal(-V). Return for DC-OK signal output. Turns the output on and off by electrical or dry contact between pin 4 (RC-), Short: Power OFF, Open: Power ON. Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. 8 -S Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. Function Manual 1.Remote Sense The remote sensing compensates voltage drop on the load wiring up to 0.5V. CN100 1 2 3 4 5 1 7 CN100 6 AUX DC-OK GND 2 AUXG RC- RC+ +S 7 -S 8 1 7 2 8 -S (Pin8) LOAD - + Sense lines should be twisted in pairs +S (Pin7) Fig 1.1 2.DC-OK Signal DC-OK signal is a TTL level signal. High when PSU turns on. Between DC-OK(pin3) and GND(pin5) Output Status 3.3 ~ 5.6V ON 0 ~ 1V OFF CN100 1 2 3 4 5 6 1 7 CN100 AUX DC-OK GND 2 AUXG RC- RC+ +S 7 -S 8 1 7 2 8 Fig 2.1 File Name:HRPG-300-SPEC 2017-07-14 HRPG-300 300W Single Output with PFC Function series 3.Remote Control The PSU can be turned ON/OFF by using the "Remote ON/OFF" function Between RC+(pin6) and RC-(pin4) Output Status SW ON (Short) OFF SW OFF (Open) ON CN100 1 2 3 4 5 6 7 CN100 1 AUX DC-OK GND 2 AUXG RC- RC+ +S 7 -S 8 1 7 2 8 SW Fig 3.1 File Name:HRPG-300-SPEC 2017-07-14